Home
OEM Systems Waterskis WS1.25EI User's Manual
Contents
1. Grey Distributor O ring retainer Only for valves that have a 32mm Distributor Tube Opening WS1El amp WS1 25El Manual Drawings and Part Numbers Page 2c WS1 amp WS1 25 Identification Figure WS1 with 1 050 Distributor Tube Opening Identification Spacer Color Grey Black Plug A 1 25 y Note The WS1 downflow piston is a solid amber color WS1 25 with 1 32 Distributor Tube Opening Identification Spacer Color Black Grey Plug WS1 25 with 32mm Distributor Tube Opening Identification Spacer Color Black 1 9 y Grey Plug Grey Ring lt lt Grey z Distributor O ring Retainer WS1El amp WS1 25El Manual WS1El amp WS1 25El Manual FOR INFORMATION COMMON TO ALL 1 amp 1 25 CONTROL VALVES REFER TO THE WS1 amp WS1 25 COMMON INFORMATION MANUAL The common manual contains the Table of Contents shown below Other Drawings and Part Numbers Compliance Table No page number Injector Cap Injector Screen Injector Plug and O ring Drawings and Part Numbers 3a Injector Order Information Drawings and Part Numbers 3b Injector Graphs US Units Injector Draw Slow Rinse and Total Flow Rates Drawings and Part Numbers 3c 3d Injector Graphs Metric Units Injector Draw Slow Rinse and Total Flow Rates Drawings and Part Numbers 3e 3f Refill Flow Control Assembly and Refill Port Plug Drawings and Part Numbers 4 Drain Line 3 4 Drawings and Part Numbers 5 Drain Line 1 Drawings and Pa
2. Instructions Service Instructions 1 5 Troubleshooting Troubleshooting 1 2 Limited Warranty Last Page Control Valve Function and Cycles of Operation Page 1 WS1El amp WS1 25El Manual Control Valve Function and Cycles of Operation This glass filled Noryl or equivalent fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a water softener or filter The WSIEI and WS1 25EI control valves are only available in downflow regeneration When the WS1EI or WS1 25EI control valve is set up as a filter the control valve can be set to perform downflow regeneration or simply backwash The control valve can be set to regenerate on demand consumption of a predetermined amount of water and or as a time clock passage of a particular number of days The control valve can be set so that a softener can meet the Water Quality Association WQA Standard S100 or NSF ANSI Standard 44 efficiency rating The control valve is compatible with a variety of regenerants and resin cleaners The control valve is capable of routing the flow of water in the necessary paths to regenerate or backwash water treatment systems The injector regulates the flow of brine or other regenerants The control valve regulates the flow rates for backwashing rinsing and the replenishing of treated water into a regenerant tank when applicable The control valve uses no traditional fasteners e g screws instead clips threaded
3. caps nuts and snap type latches are used Caps and nuts only need to be firmly hand tightened because radial seals are used Tools required to service the valve include one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disassembly for servicing takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut 12 7 mm above to 12 7 mm 2 below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC adapter power pack comes with a 4 6 meter 15 foot power cord and is designed for use with the control valve The AC adapter power pack is for dry location use only Table shows the order of the cycles and available time for the WS1EI or WS1 25EI control valve The WS1El and WS1 25EI can be used for downflow softener and filter applications as well as backwash only filters Table 1 Regeneration Cycles and Times WSIEI amp WS1 25EI Cycles of Operation Cycle Range of times min 1 Backwash 1 upflow 1 20 or OFF 2 Regenerant Draw Slow Rinse downflow 1 99 or OFF 3 Backwash 2 upflow 1 20 or OFF 4 Fast Rinse downflow 1 20 or OFF 5 Regenerant Refill with treated water 0 1 99 9 or OFF 6 Servic
4. RS PAGE 1 4 V3408EI 01 WSITHRU2L El PC BOARD ALT 1 Form No V3115El Updated 11 12 07
5. V 12V UK V3186 01 WS1 AC ADAPTER CORD ONLY AC Adapter US International Supply Voltage 120 V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 12 VAC 12 VAC Output Current 500 mA 500 mA WS1El 8 WS1 25El Manual Drawings and Part Numbers Page 2a WSI1EI Drive Cap Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly ET vow piecas o 3 vors ws Drive akpi von Ws Piston Downtow ASY 1 5 vora wsirRegeneranPison 1 08 v3105 O ring 215 Distributer Tube Ft V3001 WS1 Body ASY Downflow Not Shown 1 V3001 02 WS1 Mixing Valve Body ASY V3011 is labeled with DN Note The regenerant piston is not used in backwash only applications Black Plug Drawings and Part Numbers Page 2b WS1El 8 WS1 25El Manual WS1 25EI Drive Cap Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly Be O ring 219 Distributor Tube Opening 33 5 mm 1 32 O ring 218 Distributor Tube Opening 32 mm V3020 WS1 25 Body ASY Downflow Distributor Tube Opening 33 5 mm 1 32 V3020 01 WS1 25 Mixing Valve Body Downflow ASY Distributor Tube Opening 33 5 mm 1 32 Not Shown V3020 02 WS1 25 Body ASY Downflow Distributor Tube Opening 32mm V3020 03 WS1 25 Mixing Valve Body Downflow ASY Distributor Tube Opening 32mm Note The regenerant piston is not used in backwash only applications Grey Plug on all WS1 25 bodies Grey Ring
6. Water Specialist 1 Control Valve Series Model WS1El 1 25 Control Valve Series Model W51 25El Operation and Instruction Manual for OEM Only Please Note This operation and instruction manual is for the training of the OEM and for the OEM to use to train their customers This document is not to be used as the complete system manual WS1El amp WS1 25El Manual Table of Contents Programming Instructions Refer to 1 5 amp 2L Manual Control Valve Function and Cycles of Operation Control Valve Function and Cycles of Operation 1 2 Drawings and Part Numbers Front Cover and Drive Assembly WS1EI Drive Cap Pistons and Spacer Stack WS1 25EI Drive Cap Pistons and Spacer Stack WS1 amp WS1 25 Identification Figure Drawings and Part Numbers 1 Drawings and Part Numbers 2a Drawings and Part Numbers 2b Drawings and Part Numbers 2c FOR INFORMATION COMMON TO ALL 1 amp 1 25 CONTROL VALVEaS REFER TO THE WS1 amp WS1 25 COMMON INFORMATION MANUAL The common manual contains the Table of Contents shown below Other Drawings and Part Numbers Compliance Table Injector Cap Injector Screen Injector Plug and O ring Injector Order Information Injector Graphs US Units Injector Draw Slow Rinse and Total Flow Rates Injector Graphs Metric Units Injector Draw Slow Rinse and Total Flow Rates Refill Flow Control Assembly and Refill Port Plug Drain Line 3 4 Drain Line 1 Water Meter Meter Plug and Mixing Valv
7. e Installation Fitting Assemblies Bypass Valve Flow Diagrams Service and Backwash Flow Diagrams Downflow and Upflow Flow Diagrams Rinse and Fill WS1 Wrench General Information General Warnings Must appear in OEM s manual Specifications which must be included in OEM s Manual Quick Reference Specifications Drive Assembly Drive Cap Assembly Main Piston and Regenerant Piston Spacer Stack Assembly Injector Cap Screen Injector Plug and Injector Refill Flow Control Assembly or Refill Port Plug Drain Line Flow Control and Fitting Assembly Water Meter or Meter Plug No page number Drawings and Part Numbers 3a Drawings and Part Numbers 3b Drawings and Part Numbers 3c 3d Drawings and Part Numbers 3e 3f Drawings and Part Numbers 4 Drawings and Part Numbers 5 Drawings and Part Numbers 6 Drawings and Part Numbers 7 Drawings and Part Numbers 8a 8b Drawings and Part Numbers 9 Drawings and Part Numbers 10 Drawings and Part Numbers 11 Drawings and Part Numbers 12 Drawings and Part Numbers 13 General Information 1 General Information 1 General Information 2 General Information 2 General Information 3 General Information 3 General Information 4 General Information 4 General Information 4 General Information 5 General Information 6 Mixing Valve General Information 6 Installation Fitting Assemblies General Information 6 Bypass Valve General Information 7 8 Installation Installation 1 2 Service
8. e downflow Noryl is a trademark of General Electric WS1El amp WS1 25El Manual Control Valve Function and Cycles of Operation Page 2 The user can initiate manual regeneration The user has the option to request the manual regeneration at the delayed regeneration time or to have the regeneration occur immediately 1 Pressing and releasing the REGEN button lt q will flash towards Regen on the display and the regeneration will occur at the delayed regeneration time The user can cancel the request by pressing and releasing the REGEN button 2 Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds For additional software features and specific setup refer to the 1 5 amp 2L manual for this software Drawings and Part Numbers Page 1 WS1El amp WS1 25El Manual EI Front Cover and Drive Assembly Drawing No Order No Description Quantity 1 V3175EI 01 WSIEIFRONT COVER ASSEMBLY j 2 V3107 01 WS1 MOTOR 1 3 V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP 1 4 V3408EI 01 WSITHRU2L EI PC BOARD ALT l 5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER l V3186 WS1 AC ADAPTER 110V 12V V3186EU WS1 AC ADAPTER 220 240V 12V EU Not Shown 1 V3186UK WS1 AC ADAPTER 220 240
9. rt Numbers 6 Water Meter Meter Plug and Mixing Valve Drawings and Part Numbers 7 Installation Fitting Assemblies Drawings and Part Numbers 8a 8b Bypass Valve Drawings and Part Numbers 9 Flow Diagrams Service and Backwash Drawings and Part Numbers 10 Flow Diagrams Downflow and Upflow Drawings and Part Numbers 11 Flow Diagrams Rinse and Fill Drawings and Part Numbers 12 WS 1 Wrench Drawings and Part Numbers 13 General Information General Warnings Must appear in OEM s manual Specifications which must be included in OEM s Manual Quick Reference Specifications General Information 1 General Information 1 General Information 2 General Information 2 Drive Assembly General Information 3 Drive Cap Assembly Main Piston and Regenerant Piston General Information 3 Spacer Stack Assembly General Information 4 Injector Cap Screen Injector Plug and Injector Refill Flow Control Assembly or Refill Port Plug Drain Line Flow Control and Fitting Assembly Water Meter or Meter Plug General Information 4 General Information 4 General Information 5 General Information 6 Mixing Valve General Information 6 Installation Fitting Assemblies General Information 6 Bypass Valve General Information 7 8 Installation Installation 1 2 Service Instructions Service Instructions 1 5 Troubleshooting Troubleshooting 1 2 Limited Warranty Last Page WS1El amp WS1 25El Manual Revision History 11 12 07 DRAWINGS AND PART NUMBE