Home
USER MANUAL
Contents
1. 50 Hz Consumption 100 W 200 W Batteries Lead 12 12 Lead 12 12 v A Depending on the electrical mains the supply may be 110 V 10 60 Hz Q ERREKA 4 GENERAL DESCRIPTION 1 Door operator 2a Internal movement sensor 2b External movement sensor Safety sensor Internal release handle Moving leaf Fixed leaf Infrared barrier Digital selector O ON OO B O Key selector 10 External key 11 Floor guide 5 STANDARD DOOR FUNCTIONING 5 1 In automatic mode the door opens when it receives a signal from the movement sensor When it is fully open it stops in this position for a few seconds the opening hold time is adjustable and then closes automatically 5 2 The door remains in open position when the activation sensors detect movement in their sensing area or the safety photocells detect a person or object in the leaf displacement area 5 3 If the door encounters an obstacle on closing it stops and opens again at slow speed until it is fully open It then closes again after 5 seconds 5 4 the door encounters an obstacle during opening it stops waits for 1 second and then continues to open at slow speed until it is fully open It then closes again at normal speed 5 5 If the external key is activated the door goes to closed position and remains in this p
2. ERREKA AUTOMATION SYSTEMS AUTOMATIC DOORS C USER MANUAL Sliding door operators ERTAIN GLOBAL TELESCOPIC Q ERREKA CONTENTS 1 SAFETY AND ENVIRONMENTAL INFORMATION a senekectsxanebus skueceshtaanab xtsteetetesetaebshanead ieesiuestbessehsactshan nace 3 sarta ee ee eee ee 3 25 wh UM GEAR ol Oe ee ee ee en ee 3 4 GENERALIDESCRIPTION aorta crecido stars 4 Do PANDA DD DOOR PING TIONING 4 6 DIGITAL SELECTOR AND KEY THUMBWHEEL FUNCTIONS 5 AS nn 6 PROCEDURE IN CASE OF POWER OUTAGE manman ii 7 MAA e 7 10 DOORS WITH ANTI PANIC FITTING Optional oooocccccccccnccconocicononinonononononononononononononnnonnnnnnnnnonnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnininon 7 1 MAINTENANCE AND CLEANING ira 8 12 TROUBLE SHOOTIN G enten 8 TEGHNIGAL ASSISTANCE SERVICE 9 PO O Dl gt AA Reenen 9 Q ERREKA 1 SAFETY AND ENVIRONMENTAL INFORMATION 1 1 Safety It is essential to follow the instructions and advice given in this manual to prevent injury and possible material damage by the unit Use the personal protection equipment required for carrying out all work connected with the upkeep and maintenance of the units The instruct
3. Fax 968 804 166 puertas sureste erreka com ERREKA ANDALUCIA C Renio 3 Pol Ind Calonge 41007 Sevilla Tel 902 339 922 Fax 954 359 241 puertas sur erreka com ERREKA CATALUNYA Avda Puig dels Tudons 3 nau 36 Pol Ind Santiga 08210 Barbera del Valles Barcelona Tel 93 729 07 77 Fax 93 729 07 93 puertas catalunya erreka com ERREKA NORTH EAST Menendez Pelayo 7 bajo derecha 36202 Vigo Pontevedra Tel 986 205 102 Fax 986 296 602 puertas noroeste erreka com ERREKA LEVANTE Ingeniero Joaquin Benlloch 79 bajo 46026 Valencia Tel 963 332 046 Fax 963 353 850 puertas sureste erreka com ERREKA CANARIAS Ctra General del Sobradillo 65 38108 El Sobradillo Santa Cruz de Tenerife Tel 922 625 480 Fax 922 537 664 puertas canarias erreka com INTERNATIONAL OFFICES ERREKA MEXICO S A DE Acces IV N 31 Nave H Conjunto industrial Piti Lutx Parque Industrial Benito Juarez 76120 Quer taro Qro Tel 52 442 2216078 Fax 52 442 2216280 erreka erreka mex com www erreka mex com ERREKA DISTRITO FEDERAL Horacio 12135 Colonia Polanco 11550 M xico D F Tel 52 55 5254 1552 Tel 52 55 5254 8517 erreka erreka mex com www erreka mex com ERREKA PORTUGAL Centro Empresarial Torres de Lisboa Rua Tomas da Fonseca Torre G 1 piso 1600 209 Lisboa Tel 351 21 723 07 90 Fax 351 21 723 06 75 portas portugal erreka com Empresa Reg
4. instructions provided 11 2 Cleaning the unit Do not use a water jet Do not use abrasive products Do not expose any part of the unit to alkalis ammonia or similar Clean the glass panes periodically with specific glass cleaning products that will not damage the aluminium Clean the rest of the door with a cloth dampened in water with a neutral soap solution 12 TROUBLESHOOTING 12 1 The door remains open and will not close Ensure the door is in automatic two way mode Check there are no elements obstructing the photocell field 12 2 The function selector shows ERRORS This indicates a drop in the mains voltage Check that the 220 V mains voltage is reaching the door An overload protector may have cut out 12 3 The function selector shows ERROR6 The door goes to open position This indicates that an emergency or fire alarm signal has been received 12 4 The function selector is blocked and there are red dots between the letters on the display Key the release code if it has not been changed the standard code by default is 1111 The selector will then be released and can be worked manually 12 5 A scraping sound is heard Check visually for any elements that may be scraping against the moving leaves 12 6 BATT is flashing on the function selector The door goes to open position This indicates the batteries have failed or run down The batteries must be replaced if they are not charging correctly
5. is functioning correctly 6 2 Key thumbwheel functions The key thumbwheel does not allow door parameter adjustments to be made To change the door parameters the digital selector needs to be connected to the electronic board SYMBOL DESCRIPTION Door Closed The door closes and remains in closed position until the mode is changed If the electro lock is installed the door closes and is blocked so that no one can enter Door Open The door opens and remains in fully open position Automatic two way This is the standard functioning position This function allows two way transit Reset This is the general reset function It is used when the anti crush alarm has been triggered or if the door is not functioning correctly To activate the Reset function turn the key to Reset and then turn it to Automatic two way position Q ERREKA 7 SAFETY ELEMENTS 7 1 Electronic control safety Erreka units include an anti crush system that monitors the force exerted by the door leaves at all times 7 2 Infrared safety system Your door will be supplied with one of these two safety systems 7 2 1 Transmitter receiver photocell system If the photocell beam is broken the door will remain open as a safety measure This element must be free of any obstacles that could break the beam and it must be kept perfectly clean 7 2 2 Presence detector system I
6. If any of these problems cannot be solved run a RESET IN CASE OF ANY OTHER TYPE OF BREAKDOWN CONTACT ERREKA Q ERREKA 13 TECHNICAL ASSISTANCE SERVICE 13 1 If you have any queries or require technical assistance please contact our after sales service by calling 902501694 or sending an e mail to service erreka com 13 2 For greater durability reliability and safety we recommend you have your door periodically serviced AT LEAST TWICE A YEAR Erreka offers 3 types of periodical maintenance to adapt perfectly to your unit s requirements 13 3 Erreka has a recycling and training programme for its certified technicians guaranteeing totally professional assistance 14 ACCERORIES Remote Control Radio transmitter with a plug in receiver panel It is possible to select between 3 operating modes automatic open door or closed door The device allows selecting different operating modes open or closed door exit only or bi Digital Selector directional traffic partial opening manual gap opening etc adjusting the parameters opening and closing speed opening hold time acceleration ramps etc and performing failure diagnosis 4 position key selector The device consists of a a cylinder and a black anodised printed plate is possible to choose between operating modes automatic open and closed door as well as the reset position Proximity push button Actuator device that emits an openin
7. evice to unblock the door from the inside Switch key that allows the door to be closed from the outside It consists of a switch cylinder fixed to a black anodised aluminium plate At ERREKA Automatic doors we are concerned to adapt too ur customers needs looking to provide the end user with added value in automated access management For this reason and as a result of our innovation process a strategic key for Erreka we offer the ERREKA Control System an automatic door management system enabling up to 100 automatic doors to be controlled from a PC ERREKA AUTOMATON Sy STEMS AUTOMATIC DOORS ERREKA AUTOMATIC DOORS MATZ ERREKA S COOP FACTORY AND MAIN OFFICES Polig Ind San Juan B San Juan 93 20570 Bergara Gipuzkoa Espana Spain Tel 34 943 76 99 00 Fax 34 943 76 99 01 automaticdoors matz erreka es EXPORT Tel 34 943 76 99 00 export doors erreka com AFTER SALES SERVICE Tel 34 902 50 16 94 service erreka com 30A121 010211UK NATIONAL OFFICES ERREKA NORTH Polig Ind San Juan B San Juan 93 20570 Bergara Gipuzkoa Tel 34 943 76 99 00 Fax 34 943 76 99 01 puertas norte erreka com ERREKA CENTRE C Fisicas 62 Poligono Industrial Urtinsa II 28923 Madrid Tel 902 36 20 86 Fax 91 643 50 94 puertas centro erreka com ERREKA SOUTH EAST Pol Ind Oeste Calle Venezuela Parcela 1 12 30169 San Gin s Murcia Tel 968 891 516
8. f the detection area is occupied the door will remain open as a safety measure Avoid any elements such as plants or carpets that could obstruct this presence detection area 7 3 Panic door safety system Erreka units are equipped with an emergency opening system that moves the doors to open position if the mains voltage supply fails On some versions if the emergency battery has run down this is indicated on the display If the display shows low battery notify the technical service immediately This system is REQUIRED by law It is highly recommendable to have this system periodically serviced to prevent accident in case of emergency If the system does not work correctly people could be trapped inside the premises in case of emergency Q ERREKA 8 PROCEDURE IN CASE OF POWER OUTAGE 8 1 Panic door mode If the line voltage fails the door will open and remain in open position If the door is in Doors Closed position it will remain in this position 8 2 Autonomous mode If the line voltage fails the door will continue to function normally until the batteries run down If there is no voltage supply from either the mains or batteries the door may be opened or closed manually from both inside and outside the premises If the door has a block function optional the door i e the moving leaves can be blocked or released by activa
9. g signal when passing hand near it without any need to make contact Suitable for installations that require a high degree of hygiene conditions such as hospitals or laboratories where it is important to avoid accumulating bacteria due to hand contact Fingerprint controller Access control device with a fingerprint reader that permits access only to authorized persons In addition to fingerprint reading the device enables to include a double security system through numeric codes Numeric keyboard Activation kit nee a Electro block Q ERREKA Access control device that restricts user s access by means of numeric codes Proximity reader that enables access to staff who have transponder signal transmitter The transmitter is manufactured in a keyring format Button finished in stainless steel designed to facilitate entry for disabled people Optional remote system to facilitate installation Device consisting of an infra red presence detector plus a Push sticker Particularly suitable for installations requiring a short sensor detection scope preventing the door from opening when people walk past it The sensor is directed towards the push sticker location and it will therefore only detect presence when a person moves their hand towards the push sticker Blocking device that consists of a monostable electromagnet with a pin to block the leaves displacement cart It includes a manual d
10. ions and advice regarding maintenance of the units are not binding and Erreka reserves the right to modify them without prior notice The unit contains electrical components with 220 110 V power that could cause electrocution and moving parts that could cause trapping and injury Erreka shall not be liable for any damage caused as a result of modifications made to the installation with respect to the original product or misuse of the same 1 2 The environment The unit contains elements that could pollute the environment Find out about the applicable legislation concerning disposal or recycling of the unit 2 BASIC INTRODUCTION 2 1 This manual contains the necessary advice and instructions for the correct handling and use of the units For any modifications or issues not included in this manual please contact Erreka 2 2 The information in this manual refers to the Ertain Global and Telescopic System models 2 3 Erreka units are designed for continuous intensive use and guarantee maximum safety and a long service life 3 TECHNICAL CHARACTERISTICS CHARACTERISTICS Ertain System Global Telescopic Maximum weight per leaf 2 leaves 80 80 Kg 120 120 Kg Maximum weight per leaf 1 leaf 120 Kg 160 Kg Opening speed 0 4 0 7 m s 0 4 0 9 m s Closing speed 0 2 0 5 m s 0 2 0 5 m s Maximum closing force 150 N 150 N Ambient temperature 20 C 50 C 20 C 50 C Power supply 230 V 1090 50 Hz 230 V 10
11. istrada ER 1053 1 98
12. osition until it is deactivated In this position the sensors are disabled 5 6 If the function selector reset button is pressed the door opens and closes at slow speed and emits a warning beep When the manoeuvre is complete it goes to door closed position This manoeuvre initialises the parameters and prepares the door for correct functioning in case of failure or position loss Q ERREKA 6 DIGITAL SELECTOR AND KEY THUMBWHEEL FUNCTIONS 6 1 Digital selector functions DESCRIPTION PL The door opens and remains in fully open position 4 The door closes and remains in closed position until the mode is changed If the electro lock is installed the door closes and is blocked so f that no one can enter 5 Automatic This is the standard functioning position This function allows two way two way transit Functioning is the same as for the automatic two way mode except that 2 Automatic leaves do not open fully but only partially preventing heat loss or AN partial escape of cold air in the case of air conditioning This is only recommendable for doors with an opening clearance of over 1 2 m The door only allows transit in exit direction When the door closes it is AY also blocked to prevent manual opening from outside External detection disabled This is the general reset function is used when the anti crush alarm 8 Reset has been triggered if the door
13. ting and deactivating the block function using the manual handle External manual handle optional Pull the manual handle and open the door manually by pulling the leaves apart 9 EXTERNAL KEY Optional Closed Open The external key is a safety lock worked from the outside When the lock is turned to Closed position the door goes to Door closed status and the block function is activated if the door has FM On returning to Open position the door goes to the last function it was in before the Y lock was activated However if it was in Door closed status it will always perform an opening cycle to allow the person activating the lock to enter 10 DOORS WITH ANTI PANIC FITTING Optional The anti panic fitting enables the doors and fixed leaves to be opened outwards in case of emergency by pressing on the leaves turning the whole of the door space into an emergency exit The closing latch can 2 7 used to block and release the panic door fitting The latch should be up position so that the door can be be opened outwards in case of emergency j l Latch Up Fitting released Fitting blocked Q ERREKA 11 MAINTENANCE AND CLEANING 11 1 Maintenance of the unit Maintenance must be carried out by qualified technical staff following the relevant
Download Pdf Manuals
Related Search
Related Contents
DeWalt DW217 Instruction Manual OM, McCulloch, M105-85F, M125-85FH, 2013 Instruction manual TECHNICAL SERVICE MANUAL Product Manual 300 - Arctic Cat Thermostats programmables Advantech CE-Builder Pro 4.2 User Manual Sea Gull Lighting 15170B-965 Instructions / Assembly Copyright © All rights reserved.