1.                                              9 7  Transmission Ratio of UV Light        Figure 22  How To Measure Transmission Ratio of UV Light     Step 1 Select the    UV    after choosing the    LENS    item in the setup screen     Step 2 Pull and extract the UV cover     E    4  to calibrate the transmission ratio into       Step 3 Press the    CAL    button   100  if it is not     Step 4 Place the lens on the UV detector     Step 5 Press the    MEM    button to memorize the transmission ratio and press the       PRINT    button  ll for printing the measured data     As it measures UV transmission ratio by assuming plano concave  result  can include some error due to refractive power of measuring lens        Geen LM 7800 User Guide 47  9 8  D Sunglasses Lenses    Step 1 Select the    D SUNGLASSES    after choosing the    LENS    item in the setup  screen   Step 2 Press the    MEM    button after placing the lens over the focus           Step 3 Press the    PRINT    aro   to print them     AN INFORMATION    When measures the very dark D Sunglasses lenses  The test results  are just for reference only       9 9  Marking Focus and Cylindrical Axis    9 9 1  When there is no astigmatism    Step 1 Place the lens and control the lens so that it becomes    MARKING OK      Step 2 Turn the Marking lever  which is vertical  by 90   to make it horizontal  And  then  mark focus and cylindrical axis    Step 3 Mark focus and cylindrical axis by using the marking lever         Figure 23
2.   How To Mark Focus and Cylindrical Axis     AS  ii    9 9 2  When there is astigmatism    Step 1 Place the lens and control the lens so that it becomes    MARKING OK        Step 2 Keep    MARKING OK    and control lens up to the angle of prescription slip     Step 3 Turn the Marking lever  which is vertical  by 90   to make it horizontal  And  then  make marking focus and cylindrical axis     9 10  Prism    Step 1 Change the display format as the form  X Y  P B  mm  in the prescription  slip  You can do this on the setup screen     Step 2 Control the lens so that the display value on the screen coincides with the  prescribed prism value     Genee LM 7800 User Guide 49    10  Maintenance    10 1  Replacing Printing Paper        Figure 24  How to Replace the Printing Paper     Step 1 Open the printer cover     Step 2 Insert the paper into the printer shaft and put the shaft into the pre   defined position     Step 3 Lift the printer lever and insert the shaft with paper   Step 4 Lower the printer lever and turn the feeding velvet to roll the paper   Step 5 Close the printer cover     Step 6 Advance the paper out of the printer cover     VAN INFORMATION       Use a thermal printing paper of the width 57mm and the diameter of roll  50mm     5Q MB                    nanan       10 2  Replacing Fuse       Power Cable     Figure 25  Replacing fuse     Step 1 Pull out the fuse box     Step 2 Replace the old one with the new one     Step 3 Put into the fuse box with the new one     G
3.   vision     VAN INFORMATION    Do not lift up the lens by hand at the time of measurement  Place the lens  holder over the lens in order to hold the lens by foot  Then move the lens  forward backward or left right for measurement  Lifting up the lens may  cause the error in the measurement     JAX INFORMATION    The single Lens or the framed lens should be parallel to the lens table        Geen LM 7800 User Guide 41    9 3 4  Measuring a progressive lens for near vision power    Step 1 Move the lens to the near vision area  In case of framed lens  move  the lens till the foot of lens holder reaches to the lower frame     VAN INFORMATION    In case the framed lens  pull the lens using the lens table in order to  maintain the horizontal position     VAN INFORMATION    In case the horizontal indicator is out of the tolerance range  move the right  lens to right  left lens to left   since the near focus is located at 2 3mm  toward the center of frame        Step 2 Pull the lens till the vertical indicator for near focus reaches to the  criteria for near focus  Then  the add value will be automatically detected and  memorized with the beep sound     VAN INFORMATION     case 1  As for small framed lens  the near focus is very closed to the  lower frame  In this case  pull the lens a little bit more while lifting up the  lens holder in order to detect the near focus    figure 21          42 LM 7800    VAN INFORMATION     case 2  There may be the smallest framed lens in which the ne
4.  12  5  CONFIGURA eege aoaia deed Eegeregie 13  da  MAIN INR ee nn E 13  0 2  ACCESSORIES ooer iae a 15  6  SETTINGS AND PREPARATION FOR OPERATIN Gooooccccccooncccccccccnnnanccnnncnnanannnos 16  O    RECEIVING INSPECTION EE 16  O2       RESTART START UP ees  eege Eed ee e ech 16  6 3  DISPLAY PROTECTION FUNCTION sion di  17  7  BUTTONS FOR OPERATIONS  ina decidas 18  7 1  SWITCHING SCREEN ACCORDING TO THE BUTTON SELECTION                                 18  Te  SOSAGE OF BUTTON Sd e o A ats 19  8  DESCRIPTION OF SCREEN LAYOUT          ccc ccsscceceeeeeeeeeeeeeeeeeeeeeeeesseeaaeeeeeesseeaaeeee 21  6 4    MEASUREMENT  SCREEN EE 21    8 2  ABOUT THE PROGRESSIVE DSP AN    24    03 1 RA Gi ENEE lo OG E 25  8 4  CONTACT LENS DISPLAY  SOFT  Happ     26  8 5   D SUNGLASSES LENS DISPLAY ENNER oes 27  0     SETUP SGREEN BEE 27  SL  PRINTOUT FORMA EE 32  9  MEASUREMENTS 0 00 da ias 33  9A   NORMAL EN SES e led e ld eel e 33  02  APRAMED LENSESENSS e e he E EAS 35  9 3  PROGRESSIVE MULTI FOCAL LENSES      ananannnnonananannnnannnanrnrnrnrarrnrnnarnnrararnnrnrnrnrrna 37  9 4  GENERAL MULTI FOCAL LENSES          cccccceceececcccececcecccuccucuccececueauseeaerecseaesenaeaeneees 444  9 5  SOFT CONTACT LENSES  CONTACT LENS ZIG IS OPTIONAL   45  9 6  HARD CONTACT EE 45  9 7  TRANSMISSION RATIO OF UV LIGHT daa 46  9 8   D SUNGLASSES RE 47  9 9  MARKING FOCUS AND CYLINDRICAL AXIS        cccccececcececcecececcececeececeeeeseceeerereeteraeners 47  9 10  d EE 48  10  MAINTENANCE a ds 499  10 1  REP
5.  off the printing     AUTO PRINTER    ON    OFF    FRAME PRINT    ON    OFF    PRISM STEP    0 01    0 12    0 25    SEQ NO  DISPLAY    ON    OFF    SEQ NO    RESET    TIME      turns on the auto printing     turns off the auto printing       print the frame graph at printing     doesn   t print the frame graph at printing       display unit 0 01    display unit 0 12    display unit 0 25      show the sequential number for customer at the display     doesn   t show the sequential number for customer at the display       set the customer No 0     To configure date and time     INFORMATION    To configure date and time     EXIT    Escapes with out saving     32 MB                         VAN INFORMATION    If you take out the test lens from the lens cap after finishing the  measurement  the measured data is automatically printed out     VAN INFORMATION    Using    AUTO MEASURE        AUTO PRINTER        RS 232C     and       PRINTER     you can achieve the full automatic measurement     VAN INFORMATION    Select the input position by the left fourth and the fifth button and  increase decrease the number by the second and the third button   Pressing the first button causes escape without saving and pressing the  last button  sixth button  at the SAVE yields saving the changes        8 7  Printout Format    Printout format example is as follows    NO 00131   NAME  CHAROPS   DATE   2011 01 07 14 56  LENS   NORMAL           lt RIGHT gt   lt LEFT gt   SPH   0 00 SPH   0 00  CYL   0 
6.  or  explosive gas        BB                   nnn    Be careful not to be inserted dust  especially  metal     Don   t disassemble the product or open   We aren   t responsible for it for nothing     Be careful not to close the fan located on the lateral or  rear side of the equipment     Don   t plug the AC power cord into the outlet before the  connection between devices of the equipment is  completed  This can generate the defect     Pull out the power cord with holding the plug  not the  cord        Avoid places where the ambient temperature falls below 5  C or exceeds 40  C for normal  operation  below    25  C or exceeds 40  C for transportation and below    10  C or exceeds  40  C for storage  Humidity should be maintained between 30  and 80  for normal  operation  transportation and storage  Atmosphere should be range from 860hPa to 106  OhPa for normal operation  Avoid environments where the equipment is exposed to  excessive shocks or vibrations     Ge LM 7800 User Guide 9    2 4  Safety Precautions    This equipment has been developed and tested according to safety standards as well as  national and international standards  This guarantees a very high degree of safety for this  device  The legislator expects us to inform the user expressively about the safety aspects  in dealing with the device  The correct handling of this equipment is imperative for its safe  operation  Therefore  please read carefully all instructions before switching on this device   For more 
7.  the measured data     VAN INFORMATION    You will see one of the following figures on the left bottom of the  screen according to whether there is no lens on the lens support or  there is one           Without lens with lens   Figure 15  Display the State of Measurement     GE LM 7800 User Guide 35    VAN CAUTION    When there is no lens  you will see the figure on the left bottom of the  screen displaying lens support with no lens  If the figure displays lens  support with lens but there is no one actually  consult your agent  It  might be mechanic disorder or distortion     VAN CAUTION    In case of a lens with power  the figure on the left bottom of the screen  will display lens support with lens     VAN CAUTION    Move lens gently and softly with care  After placing the lens on the lens  support  Lower directed impact or sudden moving might result in the  scratch or crack of the lens        9 2  Framed lenses        Figure 16  Measurement of Framed Lens     Step 1 Press the    S  gt R    suton EE to enter the measuring framed lens  environment  Then     L    and    R    will be shown on the upper left and  upper right of the screen     III    VAN CAUTION    The current measuring right lens is the side of background is  highlighted with cyan color and current measuring left lens is the side  of background is highlighted with violet color        Step 2 Place the right lens on the support and lower the lens holder   Step 3 Place the PD location sensor in the middle of the f
8. 00 CYL  0 00  ANS   0 AXS   0  PSM   I 0 00 PSM   I 0 00  U 0 00 U 0 00    LM 7800     Figure 12  Printout Format of Framed Glass     LM 7800 User Guide 33    9  Measurements    9 1  Normal lenses        Figure 13  How To Measure a Normal Lens        Step 1 Press    CLEAR    ur   to initialize the state of measurement   The symbol    S    must appear on the upper right part of the screen   But       AUTO RIL     function is turned ON R L in SETUP mode    R     will be    shown    Step 2 Place the lens on the support and lower the lens holder   Step 3 Move the cross mark of prism over the center of the concentric circles       gt        OFF center ALIGNMENT OK       MARKING OK   Figure 14  Order for Focusing     SA  LN   A    Step 4 Ifthe lens has astigmatism power  turn the lens so that the astigmatism an    VAN INFORMATION    gle become 180       You don   t have to control astigmatism power to 180  if there is no  astigmatism power or you have no plan to mark astigmatism focus  and cylindrical axis        Step 5 Press    MEM    button to store the measured data  If the memorizing function  is working  data will be fixed  If you press the    MEM    button again  updat  ed value will be memorized     VAN INFORMATION      AUTO MEASURE     function is turned on in   SETUP  mode      MARKING OK     will be shown  And if you keep the state without any  action more than 1 second  the measured data will be memorized  automatically        Step 6 Press the    PRINT    button to print
9. E LM 7800 User Guide 51    VAN INFORMATION    Use 250V  T3 15AL fuse for the Auto Lensmeter LM 7800       10 3  Storage    During night time  be sure to cover the dust cloth  because some dust may spoil your  equipment     If you don   t use your equipment for one week or more  make sure that the dust cap  should be fitted into the lens support as the below picture     Dust Cap  Lens Support       52 EM    10 4  Disposal    To dispose the instrument  accessories  and components  follow local governing    ordinances and recycling plans regarding disposal or recycling of instrument or  device components  Especially a lithium battery may pollute the environment if    the instrument or a lithium battery is abandoned     When disposing packing materials  sort them by the materials and follow local    governing ordinances and recycling plans        GE LM 7800 User Guide 53    11  Troubleshooting    11 1  Various Messages    Message box shows information when you are measuring or this instrument is out of  order     Here is the description on messages that appear in measuring   ALIGNMENT OK   When the optic center falls within 0 5 prism   MARKING OK   When the optic center is correct     OFF CENTER   When the optical center of lens is off too much     Following messages are on out of working problem   NO SIGNAL   Is displayed when there is no signal   OUT OF RANGE   Is displayed when there is out of range signal     UNSTABLE SIGNAL   Contact lens measurement  when signal is bad  app
10. Key  7  Marking Lever  3 Len 8  Lens  4 oo 9  Table    10  Printer    5  Memory Button          6  UV Cover   Figure 1  Component Names  1    1  LCD 2  Key Button 3  Lens Holder  4  Lens Support 5  Memory Button 6  UV Cover  7  Marking Lever 8  Lens Table 9  Table Lever    10  Printer    14   MA di          1  Power RS EI  Wo       Figure 2  Component Names  Il               2  Power        Figure 3  Component Names  Ill      1  Power Switch 2  Power Cable    GE LM 7800 User Guide 15    5 2  Accessories    1  Printing Paper   2  Dust Cloth   3  Fuse  250V  T3 15AL    4  Tweezers   A kind of tool to pick up the contact lens  5  Power Cable   6  Dust Cap    7  User s Manual    8  Blower  9  Ink  10  Ink Case    11  Contact Lens Jig   mechanical jig for measuring a contact lens  Optional              1  2  3  SE  4  5  6   ge       SE 2 Be     1     Y  7  8  9   EY       UCD   Dr CIE    6  Settings and Preparation for Operating    6 1  Receiving inspection    Step 1  Checking accessories   12  Open the box and make sure that all the accessories  printing paper  Dust Cloth  user   s    manual and so on  are in it    Step 2  Removing the protection tape     Remove the protection tape from the lens holder  lens support  marking pen  and the UV cover     6 2  Test at Start up    Step 1  Connecting the power cable     Connect the cable into the power receptacle on the bottom of the body     Step 2  Checking the initial status     Turn on the power switch and make sure that this instr
11. LACING PRINTING PAPER         cccecsccccecsccecsccececuecececuecessectseeaeeusseaeaenseaenectees 499  10 2  REPLACINO USE dede A T let lee anti 50  10 3  AO A A eege 51  10 4  cs OY Sd D A On a 52  11  TROUBEESHOOTIN CG cocina ts 533  11 1  VARIOUS MESSAGES aia o e a ce Sodio Lal Mt Sedo da eo aa 533  11 2  HOW TO CLEAN PIM OLE e eS 53  12    SPECIEICATONSS A e en eee 54    1392   SERVICE INFORMATION  ar o 55    A TA    1  Introduction  1 1  Outline of the instrument    The Automatic Lens meter LM 7800 is the equipment for measuring the refractive  power of lenses and gives the spherical  cylindrical and axis of the lenses    The Automatic Lens meter LM 7800 also contains the PD  pupil distance   measurement and the UV Protection Ratio Test  The automatic lens meter  LM 7800 can measure both the uncut singular lenses and the framed glasses   Recently the Bi Focal lenses or Progressive lenses for the elderly can be check  with this equipment  And also this instrument can measure soft contact lenses  easily and accurately using the specialized mechanical jig and the detailed display     1 2  Classification    Protection against electric shock  Class I earthed   Installation Category  Il  Pollution Degree  2    NEE LM 7800 User Guide 5    2  Safety Information    2 1  Introduction    Safety is everyone s responsibility  The safe use of this equipment is largely  dependent upon the installer  user  operator  and maintainer  lt is imperative that  personnel study and become famili
12. LM 7800 Lensmeter       Operation Manual       LUXVISION    GE LM 7800 User Guide 1    IMPORTANT NOTICE    This product may malfunction due to electromagnetic waves caused by portable  personal telephones  transceivers  radio controlled toys  etc  Be sure to avoid  having objects such as  which affect this product  brought near the product     The information in this publication has been carefully checked and is believed to  be entirely accurate at the time of publication  LUXVISION assumes no  responsibility  however  for possible errors or omissions  or for any consequences  resulting from the use of the information contained herein     LUXVISION reserves the right to make changes in its products or product  specifications at any time and without prior notice  and is not required to update  this documentation to reflect such changes     LUXVISION  9990 NW 14 Street Doral  FL 33172    All rights are reserved   Under copyright laws  this manual may not be copied  in whole or in part   without the prior written consent of LUXVISION     EE E    CONTENTS  1  INTRODUCTION Socia a ee a nn eee tentent 4  dida  OUTLINE OF THE INSTRUMEN Tissot is 4  152  CLASSIFICATION ASS A dt nr Le ter 4  2  SAFETY INFORMATION  nee ege 5  251  INTRODUCTION EE 5  22 E O el EE 6  2195 ENVIRONMENT a T  2      SAFETY PRECAUTIONS  a ee eege A ere 9  3  FEATURES oscar ebe e eebe se fn denon EEeebteseget  en 11  4  NOTES FOR USING THE INSTRUMENT              ccccceeeeeeeeeeeeeeeeeeeeeeeeeaeeeseeeseeeaaees
13. RE  AUTO RIL  PRISM DISPLAY    ABBE NORMAL    NORMAL 60    MID        Figure 11  Setup Display     28 TA a aa    8 6 1  Detail explanation    LENS    NORMAL   normal lens    PROGRESSIVE   progressive lens    SOFT CONTACT   soft contact lens    HARD CONTACT   hard contact lens    UV   Uv lens    SUNGLASSES  dark sunglasses lens  CYLINDER    MIX   displays the cylinder value with     sign when the power has      value and with     sign when the power has     value        always displays the cylinder value with     sign        always displays the cylinder value with     sign   PROGRESSIVE AUTO    ON   auto detection of progressive lens     OFF   turns off the progressive function     AUTO MEASURE     ON PROG ON    turns on auto storing function      turns on auto storing progressive function     ON PROG OFF     turns on auto storing function      turns off auto storing progressive function     OFF PROG ON     turns off auto storing function      turns on auto storing progressive function     OFF PROG OFF    turns off auto storing function      turns off auto storing progressive function     AUTO R L    ON R L   turns on auto decision of right or left lens  Initially  this system is  ready for measuring the right lens     ON S R L    turns on auto decision of right or left lens  Initially  this system is  ready for measuring the single lens     OFF S RLL   turns off auto decision of right or left lens     PRISM    NO DISPLAY    will not display the prism information    XY   displ
14. and prepare the contact lens jig  Rotate two  jogs for the body to go to the middle of the structure    Clear the moisture on contact with lens toil  And then wait about in 10sec  to make its shape rounded    Take out the soft contact lens with a tweezers and place the soft contact  lens on the cap of the mechanical jig    Place the mechanical jig on the pin hole housing  Rotate two jogs for the  cross marker to go to the center of the display    Be sure that the heights of all score bars are higher than the criteria line   Otherwise wait a little bit more  or move the soft lens a little bit so that the  height of score bars become equal or more than the criteria line     Press the    START RECORD    button   MM to trigger the continuous  measurement  After a few second  Press the    STOP RECORD          button   n       VAN INFORMATION    You can specify the measurement duration at the User Setup Page  And  then if you turn on the    AUTO REC    function  it is unnecessary for you to    press     STOP RECORD    button  f to stop the continuous    measurement  It stops automatically after the specified seconds        9 6  Hard Contact Lenses    Step 1 Select the    HARD CONTACT    after choosing the    LENS    item in the setup  screen     Step 2 Wipe off the water and place the lens with its convex surface down   Step3 Press the    MEM    button to store the measured data and press the    PRINT       button       to print them     46 LM 7800                                  
15. ar focus is  cut out  In this case  adjust the lens to make the level of vertical indicator  minimized while securing the tolerance range of horizontal indicator  Then  press     MEM     button to set the focus of near vision   Measurement date  may be a little bit different from the actual data     figure 21           Case 1 Case     Figure 21  The small framed lens     VAN INFORMATION    The old type progressive lens may not observe the 2 3mm shift toward  the frame center        9 3 5   roubleshooting for progressive measurement    Do not detect the progressive lens automatically  Cause 1   Lens holder is not located in the progressive area  Normal lens icon  will be displayed in the left bottom of display      Solution Move the lens to the progressive area for progressive measurement     Cause 2   The progressive power is less than 1D     Solution   Move the lens to the close point of near focus and then press  MEM   button for progressive measurement     Detect the normal lens as the progressive lens    Cause 1   Lens is not properly manufactured  enormous deviation in the lens   Solution   You can cancel the progressive auto detection function in set up  display for system variable  Refer to Section 8 6       Difficult to detect the far vision focus    Geen LM 7800 User Guide 43    Cause 1   The progressive area is expanded into the far vision focus  Solution   Place the cross marker    at the close point to the center and press   MEM  button to set the focus of far vis
16. ar with this entire manual before attempting to  install  use  clean  service or adjust this equipment and any associated accessories   It is paramount that the instructions contained in this manual are fully understood  and followed to enhance safety to the patient and the user operator  It is for this  reason that the following safety notices have been placed appropriately within the  text of this manual to highlight safety related information or information requiring  special emphasis  All users  operators  and maintainers must be familiar with and  pay particular attention to all Warnings and Cautions incorporated herein     ZN WARNING       Warning    indicates the presence of a hazard that could result in severe  personal injury  death or substantial property damage if ignored        Note    describes information for the installation  operation  or maintenance of  which is important but hazard related if ignored     VAN CAUTION       Caution    indicates the presence of a hazard that could result in minor injury   or property damaged if ignored     VAN INFORMATION       Information    each page will briefly describe the information being requested  and the browser will open with information relative to your position        D LM 7800 een    2 2  Safety Symbols    The International Electrotechnical Commission  IEC  has established a set of  symbols for medical electronic equipment which classify a connection or warn of  any potential hazards  The classifications and symbo
17. ays the prism information in X Y coordinates     GE LM 7800 User Guide 29     PB   represents the prism information with absolute distance and  angle     mm   displays the center difference in  x  y  coordinate by    millimeter  mm      ABBE    NORMALDATA XX    value applied ABBE constant    MIDDATA XX    value applied ABBE constant    LOWDATA XX    value applied ABBE constant   This can be applied to the high refractive lens   L NORMAL XX    XX   designated value for NORMAL ABBE  50 60   L MID XX    XX   designated value for MID ABBE  40 49   L LOW XX    XX   designated value for LOW ABBE  30 39   PRISM MODE    5 P MODE   display unit 5 P     10 P MODE   display unit 10 P    15 P MODE   display unit 15 P   BPS  Selects the speed of the external communication    9600   Communication speed by 9600     19200   Communication speed by 19200     38400   Communication speed by 38400     57600   communication speed by 57600       115200    communication speed by 115200     SPH CYL STEP    0 25   display unit 0 25    0 125   display unit 0 125    0 01   display unit 0 01  WAVELENGTH        Line   displays the refractive power according to e Line      d Line   displays the refractive power according to d Line    30 LM 7800                                  SLEEP MODE    ON   turns on the display protection mode     OFF   turns off the display protection mode   RS 232C  Selects the protocol of RS 232C    OFF   turns off the external communication    WAVE LINE   turns on the protocol bet
18. current data and to memorized the average value    MEM button    To memorize the current measured value    Geen LM 7800 User Guide 21    8  Description of Screen Layout    8 1  Measurement Screen    1  Active Direction 4  Measuring point    5  Lens Type  2  Cylinde 3  Sequential No 6  Measured Data    d wb d  A Ms R      NORM L    S 0 00  C 0 00  A 0    0 00  Pu 0 00    PD 0 0  10P  ABBE 60  PD 0 0    Marking D      eegend             MO FS       7  Message Box  8  State icon     Figure 6  Screen Layout              11  Total PD       10  ABBE Data       9  Prism Type    22 A LL    8 1 1     Detail explanation    Active Direction    Tells whether current lens is a single or a left right lens     Cylinder    Displays the cylinder value with     sign when the power has     value and with      sign when the power has     value     Sequential No    Show the sequential No for the customer identity     Measuring point    Show the current measuring point on the surface of the lens     Lens Type    Tells whether the current lens in measuring is a general lens  a progressive  lens  a soft contact lens  a hard lens  a uv lens or a d sunglasses lens       Measured Data    Box for displaying the measured data  Each meaning of the content is as show  n below     S   basic power  e  C cylinder power  A   cylinder axis  Oo P   prism X  prism Y  e PD RPDorLPD    e ADD  progressive power 1 and 2      Message Box    Notifies states of measurement and warnings and so on   eo ALIGNMENT OK   is d
19. detailed information  please contact our Customer Service Department or one of  our authorized representatives     1  This equipment must not be used  a  in an area that is in danger of explosions  and  b  in the presence of flammable  explosive  or volatile solvent such as alcohol   benzene or similar chemicals     2  Do not put or use this device in humid rooms  Humidity should be maintained  between 50 and 80  for normal operation  Do not expose the device to water  splashes  dripping water  or sprayed water  Do not place containers containing  fluids  liquids  or gases on top of any electrical equipment or devices     3  The equipment must be operated only by  or under direct supervision a  properly trained and qualified person     4  Modifications of this equipment may only be carried out by Luxvision s  service technicians or other authorized persons     5  Customer maintenance of this equipment may only be performed as stated in  the User s Manual and Service Manual  Any additional maintenance may only be  performed by Luxvision s service technicians or other authorized persons     6  The manufacturer is only responsible for effects on safety  reliability  and  performance of this equipment when the following requirements are fulfilled   1  The  electrical installation in the respective room corresponds to the specifications stated  in this manual and  2  This equipment is used  operated  and maintained according to  this manual and Service Manual     T  The manufactur
20. e steps below     First of all  refer to the 10  Maintenance and 11  Troubleshooting sections  according to the problem that you are encountered  And then follow the  suggested sequences     If the problem persists  please contact the local distributor in your province  or country at first     Before calling to the local distributor  you d better check these information  such as Model and Serial Numbers  To do so  fill up the following table as  soon as you purchase our product  You can look up these information at any  time  The serial number is found on the back of this unit  The serial number  is unique to this unit  You should retain this manual as a permanent record  of your purchase  Please retain your purchase receipt as your proof of    purchase     Date of Purchase    Dealer s Name    Dealer Address    Dealer Phone No     Model No     Serial No     If you can   t contact with your local distributor  you can directly get in touch    with the service department of the LUXVISION using the phone number and    the address written in the below table      gt   LWM  800 Lensmeter    A LUXVISION    9990 NW 14 Street   Suite 105   Doral  FL 33172  Telephono  888 334 4640    
21. ear     11 2  How to clean pin hole    While your machine is being started up  if there is the warning message     No Signal     or  Out of range     please clean the 4 pin hole at first  Just use your lens towel  But     dont use liquids such as alcohol  acetone  etc     AN CAUTION    Never use liquids such as alcohol  acetone  etc  Because such liquids  might melt the glue on the 4 pin hole        After that  if the message    No Signal    or    Out of range    isn   t be disappeared  please    ask to your local distributor or the LUXVISION service department     54  ENT    12  Specifications    Measurement Range    Sphere Power  25D    25D    Cylinder Power O to  10 00D  Cylinder Axis 0     180   degrees 1   Step   Add Power O to  10D    Prism Power 0 to 15A    Precision  Diopter Steps 0 01   0 125  0 25D    Prism Power 0 01  0 125   O 25A    Measurement Modes    Cylinder    4  J    Prism Rectangular   Polar Displacement    Sampling Speed 0 016 seconds    LED Wavelength 545 nm    Contact Lenses Hard and Soft    Abbe Values Manual Compensation    Wavelength e Line  d Line    TFT LCD Display    Display  320X240 LED Backlight     Data Output RS 232C  Printer    BPS 9600 19200 38400 57600 115200 bps    SE 196  W  x 253  D  x 398  H  mm  7 72 in  x 9 96 in  x 15 70 in     Weight 5 5Kg    Power Supply AC 100   240 V    50 60Hz  1A       GE LM 7800 User Guide 55    13  Service Information    How to contact service  lf there are any problems with the equipment  please    follow th
22. ect this with other equipments  consult the dealer     Sudden heating of the room in cold areas will cause condensation of vapor on  the protective glass in the measurement window and on optical parts inside the  instrument  In this case  wait until condensation disappears before performing  measurements     To get accurate measurements  always keep it clean  Dust may result in  malfunction  After using this instrument  turn off power supply and keep the  dust cover over it     Don t use organic solution such as thinner  benzene  etc  to clean the surface  of this instrument  It may damage the instrument    There is a risk of explosion if an incorrect type of battery is used  Dispose used  batteries according to the instructions     Disconnect the power supply and consult the dealer in case of smoke  strange  odors  or noise during operation     Don   t place anything on the lens cap while this instrument is turning on  This  instrument should perform the self test at start up     Don   t turn off the Display Protection Mode without an unavoidable reason   That   s why this instrument should perform the Display Protection function for  the display protection as well as the compensation of temperature     Don   t place anything on the lens cap when you wake up this instrument from  the display protection state  That   s why this instrument should perform the  compensation of temperature at the moment     GE LM 7800 User Guide 13    5  Configurations    5 1  Main Unit    1   2 
23. er is not liable for damage caused by unauthorized tampering  with the device s   Such tampering will forfeit any rights to claim under warranty     10  LM 7800                                 8  This equipment may only be used together with accessories supplied by  Luxvision  If the customer makes use of other accessories  use them only if their safe  usability under technical safety aspects has been proved and confirmed by Luxvision  or the manufacturer of the accessory     9  Only persons who have undergone proper training and instructions are  authorized to install  use  operate  and maintain this equipment     10  Keep the User s Manual and Service Manual in a place easily accessible at  all times for persons operating and maintaining the equipment     11  Do not force cable connections  lf a cable does not connect easily  be sure that  the connector  plug  is appropriate for the receptacle  socket   If you cause any  damage to a cable connector s  or receptacle s   let the damage s  be repaired by an  authorized service technician     12  Please do not pull on any cable  Always hold on to the plug when disconnecting  cables     13  This equipment may be used for the international application related to the  inspection of general lenses according to this manual     14  Before every operation  visually check the equipment for exterior mechanical  damage s  and for proper function     15  Do not cover any ventilation grids or slits     16  Immediately turn off and unplug a
24. erent  pictures for protecting the display component  If you press any button on this mode  it  will return to the measurement screen  Be sure that dont turn off this display protection  function in the User Setup Display without an unavoidable reason     18 LM 7800 eneen    7  Buttons For Operations    7 1  Switching Screen According To the Button Selection       D Sunglasses Lens Mode     Figure 5  Switching Screen According To the Button Selection     WE LM 7800 User Guide 19    7 2  Usage of buttons    Ex    MODE       Setup Screen will be shown    9    TRNS    To transpose the sign of cylindrical reading       PROG    Enter the Progressive Multi Focal Screen    p     Sea SOFT CNCT    To go into the display for soft contact lens    J    HARD CNCT    To go into the display for hard contact lens       UV    To Enter the UV Measurement Screen    D SUN       To measure the heavy dark sunglass lens    20 LM 7800                                                                                  LENS    To return to the display for the normal lens       S R    In case of single lens  you can switch between left and right selection of  the framed lens or you can select left  right lens    CLEAR    To Initialize data and convert screen  You can initialize data and screen by  using this button    PRINT    To print the current memorized data    P    CAL    To set the current state of transmission into 100     RUN    To start recording the current data    STOP    To stop recording the 
25. ion    Cause 2   The far focus is close to the upper frame  Solution   Push the lens a little bit more while lifting up the lens holder in order  to detect the far focus    Difficult to detect the near vision focus  Cause 1   The near focus is close to the lower frame  Solution   Pull the lens a little bit more while lifting up the lens holder in order  to detect the near focus     Cause 2   The near focus is cut out because of small framed lens   Solution   adjust the lens to make the level of vertical indicator minimized  whiling securing the tolerance range of horizontal indicator  Then  press  MEM  button to set the focus of near vision in case the add  power is maximized   Measurement date may be a little bit different  from the actual data     Error in the measurement data  especially the lens over  4D of near vision power    Cause 1   Lift up the lens by hand at the time of measurement   Solution   Place the lens holder over the lens in order to hold the lens by foot   Then move the lens forward backward or left right for measurement     Difficult to maintain the horizontal position in case of near vision measurement  Cause 1   Wrong measurement of far vision focus  Solution   Retry the measurement of far vision focus    The marker  O    is displayed more than two times  Cause 1   The lens is not properly manufactured  more than to points with the  deviation of progressive power   Solution   Detect the maximized add value of the points     det  ENEE    9 4  General Mul
26. isplayed when the optical center  falls within 0 5 prism     GE LM 7800 User Guide 23      MARKING OK   is displayed when the optical center is  precise  And it tells that you can mark  focus and cylindrical axis after you adjust  the angle using the marking lever     e NOSIGNAL   is displayed when there is no signal    e Out Of Range   is displayed when there is out of range  signal    Oo Printing   is printing    e Unstable Signal   contact lens measurement  when signal    is bad  appear     State Icon  Represents that there is no lens inserted on the left bottom of the screen  If  you insert a lens  a figure will be shown  which illustrates lens on the lens  support     VAN INFORMATION    The lens icon with a curved band represents the progressive lens  inserted on the lens cap        O Prism Type   Is displayed selecting 5 Prism  10 Prism   ABBE Data   Is displayed ABBE Value     4d Total PD    Shows the total PD reading that is the summation of the left PD reading and  the right PD reading     2A A    8 2  About the progressive display    ADD  0 22    1  Measuring Point    2  Target  D 1 54  PD  ABBE 60  ADD 0 22 3  Add Value    P Gr xo Di        Figure 7  The display for the progressive powered lens     8 2 1  Detail explanation     Y  Measuring Point    This cross marker displays the current measuring point while finding the far  focus      2  Target    You should move the cross marker to the center of the target for far focus      3  Add Value    This rectangle shows 
27. ls are shown below     Save these instructions      and O on power switch represent ON and OFF  respectively     This symbol identifies a safety note  Ensure you  understand the function of this control before using it   Control function is described in the appropriate User s  or Service Manual     Manufactured by xxxx  year      Disposal advise for EU    Manufacturer    Identifies the point where the system safety ground is  fastened to the chassis  Protective earth connected to  conductive parts of Class   equipment for safety  purposes        Extra Symbols  External serial communication port  User can transmit  the memorized data to other LUXVISION equipment  like LDR 7800  LDR 7800 is also a approved    equipment complied with CE certificate   For detailed  connecting method  please refer the connected device  manual  ex  LDR 7800 manual       Gen LM 7800 User Guide 7    2 3  Environment factors    Avoid the following environments for operation or storage    Where the equipment is exposed to water vapor   Don   t operate equipment with a wet hand     Where the equipment is exposed to direct sunlight     Where the temperature changes extremely   Normal operating temperature range is from 5  C to 40  C   Relative humidity is from 30  to 80      Where it is near the heat equipment     Where the humidity is extremely high or there is a  ventilation problem     Where the equipment is subject to excessive shocks or  vibrations     Where equipment is exposed to chemical material
28. n locate the left lens  In that case   Auto R L      function is properly operated        9 3  Progressive Multi Focal Lenses    9 3 1  The structure of progressive powered lens    The Uncut Lens    EA Lens Table            CS   X Eye point mark for near    Eye point mark for distance  far      Figure 17  The structure of single lens     VAN INFORMATION    The lens should be placed with its horizontal marks parallel to the lens  table     PAN INFORMATION  Initially the lens should be placed as shown in the picture  The near  vision area is beside of the lens table        TI     The Mounted Lens        Figure 18  The structure of the typical progressive frame lens     VAN INFORMATION    The dimension of progressive powered lens depends on the  specification of manufacture     VAN INFORMATION    The old type progressive lens may not observe the 2 3mm shift toward  the frame center     VAN INFORMATION    Do not lift up the lens by hand at the time of measurement  Place the  lens holder over the lens in order to hold the lens by foot  Then move  the lens forward backward or left right for measurement  Lifting up the  lens may cause the error in the measurement        9 3 2  Judging progressive lens       Step 1 Make sure that the icon in the left bottom of display is in the    standard mode as picture     Step 2 Place the lens over the lens cap and wait 1 2 seconds     GE LM 7800 User Guide 39    VAN INFORMATION    It is recommended to place the lens holder over the marked      p
29. ny equipment that gives off smoke  sparks   strange noises  or odors     Gen LM 7800 User Guide 11    3  Features    1  You can measure the center and refraction power of lenses with ease and rapidity     2  In case of framed lens  single binocular PD can be measured automatically in  addition to the refraction power of each lens     3  Transmission ratio of UV  Ultra Violet  light can also be measured with this LM 7800     4  LM 7800 provides the wide measurement range from    25D to  25D     9  LM 7800 supports precise measurements guaranteed by 0 01D measurement  unit     6  Measuring progressive multi focal lenses and general multi focal lenses can be  performed easily and rapidly     7  LM 7800 can measure soft contact lenses easily and accurately using the  specialized mechanical jig and the display   but  contact lens zig is optional     8  LM 7800 supports gorgeous displays through the proper colored LCD     9  The measured data can be provided to the customers by using the printing  function     4     12  A A aaaaaa    Notes for using the instrument    10     11     12     Do not hit or drop the instrument  The instrument may be damaged if it  receives a strong impact  The impact can damage the function of this  instrument  So handle with care     Install this instrument on a level  stabilized table with no vibration to keep it  normal state     Exposure to direct sunlight or very bright indoor lights can influence the results  of measurements     If you want to conn
30. rame when PD function    is on   Step 4 Press the    MEM    button to store the measured data   Step 5 Lift the lens holder and place the left lens     AN CAUTION    When the PD functions on  whether the lens is for right or left can be  automatically detected from the location of the PD sensor  Because this    detection has priority to the selection of the   S  gt R     button      the    selection of the   S  gt R     button  Si will be ignored     AN CAUTION    O    You should use the   S  gt R     button   EES  to select the lens for  measuring in the following three cases  when PD function  option  is  not supported  PD function is off  or   AUTO R L    function is off        Step 6 Move the lens so that the MARKING OK    appears  focusing   And place  the PD location sensor in the middle of the frame when PD function is on   Step 7 Press the MEM button to store the measured data and press the    PRINT       button El to print them   VAN INFORMATION    If you don t want the PD value  you can use the lens table and the    horizontal support without using the PD location sensor  In this case   completely turn the PD location sensor out from the hooker  Otherwise   it can result in the interference between the PD location sensor and the       lens     Gen LM 7800 User Guide 37    AN CAUTION    In case that   Auto R L     function is on and PD function is off  after the    right lens is completed you should identify the   No lens     icon in the left  bottom display  And the
31. rogressive powered band                      Figure 19  The progressive area for the automatic detection     Step 3 The icon in the left bottom of display will be changed as below  Standard  Progressive icon   The display will be automatically changed to  progressive mode         Figure 20  The changes of state icon     VAN INFORMATION    Automatic Detection may not be available in case the progressive power is  less than 1D        If so  press  PROG  EH for progressive measurement     AQ  RE    VAN INFORMATION    If the lens is not properly placed in Step 2  the normal lens icon  as picture     will  be displayed in Step 3  In this case  move the lens to the progressive area       for progressive measurement     9 3 3  Measuring a progressive lens for far vision power    Step 1 Move the lens to the far vision area  In case of framed lens  move the lens  till the foot of lens holder reaches to the upper frame     Step 2 Adjust the lens left right  horizontal  or forward backward  vertical  in order to  place the cross marker     at the center of target for far focus     Step 3 The power of far focus will be automatically detected and memorized with  the beep sound in case the cross marker     is placed at the center properly     VAN INFORMATION    Automatic detection may not be available if the progress area is expanded       into the far vision focus  In this case placed the cross marker     at the  close point to the center and press   MEM     button to set the focus of far
32. the current ADD value     GE LM 7800 User Guide 25    8 3  UV Screen    mee    HO 20 2  Current  Transmission Ratio    1  Left 3  Right       Transmission Ratio Transmission Ratio    4  Transmission    ABEE 60  PO 0 0 Height        Figure 8  UV Screen Layout     8 3 1  Detail explanation    O Left Transmission Ratio    Shows the left side stored value        Current Transmission Ratio    Displays the transmission ratio in a bar graph form        Right Transmission Ratio    Shows the right side stored value        Transmission Height    Shows the height of the current transmission height     26 LM 7800 e nnn nennnennnnennnnennnes    8 4  Contact Lens Display  Soft  Hard     NO  20    1  Signal    10P Y  ABBE 60  PD 0 0       2  Start Stop Record  3  Score Graph  Of Each Point     Figure 9  Contact Lens Display     8 4 1  Detail explanation    O Signal    Shows the share of every signal        Start Stop Record    Start   Start recording the continuous measurement    Stop  Stop recording the continuous measurement  calculates the average  value of all readings and then stores them          Score Graph for Each Point    Shows the score of every signal  If one of them is lower than the criteria line     Geen LM 7800 User Guide 27    the reading at that moment must be thrown away     8 5  D Sunglasses Lens Display    HO 20    dh    10P  ABBE 60    Marking OK        Figure 10  D Sunglasses Lens Display     8 6  Setup Screen    NORMALLENS  CYLINDER MODE  PROGRESSIVE AUTO  AUTO MEASU
33. ti focal Lenses    9 4 1  Measuring at the Normal Display    Step 1 Press the    MEM    button after placing the lens over the first focus     Step 2 Press the   MEM     button after placing the lens over the second focus   The first    ADD    value will be shown     Step 3 At this time  ADD value isn   t frozen  Therefore if you guess the value  correct  press the   MEM button once more    Step 4 Press the     ADD     autor  7 to enter the measurement mode for the  second ADD value         Step 5 Press the    MEM     button after placing the lens over the third focus  The  second    ADD     value will be memorized     9 4 2  Measuring at the Progressive Display    Step 1 Press the     PROG     button EI to activate the progressive display   Step 2 Place the lens over the first focus   The measurement is done automatically   Step 3 Move the lens over the second focus  And then the measurement is  done automatically     VAN INFORMATION       At every step  in case that automatic measurement isn   t done or you want  a manual decision  please press the   MEM     button    Gen LM 7800 User Guide 45    9 5  Soft Contact Lenses  contact lens zig is optional     We have to prepare the mechanical jig for measuring a soft contact lens  The  procedures to measure a soft contact lens are as followings     Step 1    Step 2    Step 3    Step 4    Step 5    Step 6    Step 7    Select the    SOFT CONTACT    after choosing the    LENS    item in the setup  screen    Remove the lens support 
34. ument is functioning  properly  While starting the equipment  be sure not to place anything on the  lens cap  If you encounter any problem with your equipment during boot up   you ll see the following message on the screen display        No Signal    or    Out of range       If so  clean the 4 pin hole  Refer to Section 11 2    How to clean the 4 pin hole      And then turn on again  If the problem persists  please contact your local  distributor or the manufacturer  Refer to the chapter 13     Service Information    In  summary  the testing procedures at start up are as followings     Gen LM 7800 User Guide 17    a  Turn on the machine  Make sure that there is nothing on the lens cap    b  If you encounter the message    No Signal    or    Out of range     please clean the 4   pin hole  And then turn on again    c  Ifthe problem persists  please contact your local distributor or the manufacturer    d  Otherwise  check the values SPH  CYL  AXIS at Measurement Screen about  which is explained in the section 8 1    Measurement screen       e  If SPH  CYL  or AXIS aren t zero  clean the 4 pin hole  And then turn off and on  again  If the problem persists  please contact your local distributor or the  manufacturer    f  If SPH  CYL  and AXIS are zero  it s okay with your equipment     6 3  Display protection function    When the instrument is not used for a few minutes  display protection function works  automatically  In display protection mode  the instrument shows several diff
35. ween LM Model and LRK   LDR series     LMTORK NEW    turns on the bilateral protocol between LM Model  and LRK  LDR series   BEEP    ON   turns on the beep sound function     OFF   turns off the beep sound function   CONTACT REC    MANUAL REC   stop the continuous measurement by pressing     STOP  button by user     AUTO REC XXs   measure for the specified second and then stop  automatically     AUTO REC    XXS   designate the seconds for the continuous  measurement     NAME  You can input the company name here  The company name will be displayed  at the upper part of the printing paper        VAN INFORMATION    Select the input string by using the second  third  fourth and the fifth  buttons from the left side and select the displaying position by the sixth    button  Pressing the first button causes escape without saving and  pressing the last button  sixth button  at the SAVE yields saving the    changes   PD    ON DEFAULT    turns on the PD function    OFF   turns off the PD function      ON  AVERAGE ST    turns on the special PD function that makes the RPD  and LPD even in case that the difference between    eee eee nnn nnn nnn LM 7800 User Guide 31    RPD and LPD is less than 3mm     LANGUAGE    ENGLISH MODE   display as the English mode     CHINESE MODE   display as the Chinese mode     TURKCE MODE   display as the Turkce mode     FRENCH MODE   display as the French mode     GERMAN MODE   display as the German mode  PRINTER    ON   turns on the printing     OFF   turns
    