1.                            15    HandyTone 486 User Manual Grandstream Networks  Inc     54 FAX    HandyTone 486 supports FAX in two modes  T 38  Fax over IP  and fax pass through  T 38 is the  preferred method because it is more reliable and works well in most network conditions  If the service  provider supports T 38  please use this method by selecting Fax mode to be T 38  If the service  provider does not support T 38  pass through mode may be used  To send or receive faxes in fax pass  through mode  users will need to select all the Preferred Codecs to be PCMU PCMA     5 5 LED Light Pattern Indication    Following are the LED light pattern indications        RED LED indicates abnormal status                      Button flashes every 1 second Ethernet link is down   Button flashes every 2 seconds DHCP Failed or WAN No Cable   if DHCP is configured    Button flashes every 4 seconds HT 486 fails to register    if SIP server is configured    Button flashes every 6 seconds Firmware Upgrading   Button flashes briefly No STUN responses   Red light steady  Device Malfunctions          Green LED indicates normal status                         Button flashes every 2 second Message Waiting Indication  Button flashes every 1 10 second Ringing   Button flashes every second Ringing interval   Green light steady In conversation       16    HandyTone 486 User Manual Grandstream Networks  Inc     6 Configuration Guide    6 1 Configuring HandyTone 486 through Voice Prompt     1 1 DHCP Mod
2.                Key Call Features    23 3 way conference    87 Blind Transfer    30 Block CallerID  for all config change     31 Send CallerID  for all config change     67 Block CallerID  per call     82 Send CallerID  per call     50 Disable Call Waiting  for all config change   AS Enable Call Waiting  for all config change    70 Disable Call Waiting   Per Call     71 Enable Call Waiting  Per Call    nz Unconditional Call Forward     To use this feature  dial     72     wait for the dial tone  Then dial  the forward number ended with    wait for dial tone  hang up    73 Cancel Unconditional Call Forward   To cancel    Unconditional Call Forward     dial     73    and get the  dial tone  then hang up     90 Busy Call Forward   To use this feature  dial    90     wait for the dial tone  Then dial  the forward number ended with    wait for dial tone  hang up    91 Cancel Busy Call Forward   To cancel    Busy Call Forward     dial     91    and get the dial  tone  then hang up    92 Delayed Call Forward   To use this feature  dial     92     wait for the dial tone  Then dial  the forward number ended with    wait for dial tone  hang up    93 Cancel Delayed Call Forward   To cancel this Forward  dial     93    and get the dial tone  then  hang up   Flash Hook   When in conversation  this action will switch to the new  incoming call if user heard the call waiting sound    When in conversation and no incoming call heard  this action  will switch to a new channel for a new call     
3.   IP Address       IP address The current WAN IP address is announced  Enter 12 digit new IP address if in Static IP  Mode    03    Subnet       IP address Same as Menu option 02   04    Gateway       IP address Same as Menu option 02   05    DNS Server       IP address Same as Menu option 02   07 Preferred Vocoder Enter    9    to go to the next selection in the list      PCM U    PCMA     G 723     G 729     iLBC     G 726   12 WAN Port Web Access Enter    9    to toggle between      enable    disable   13 Firmware Server IP Address The current Firmware Server IP address is  announced  Enter 12 digit new IP address    14 Configuration Server IP The current Config Server Path IP address is   Address announced  Enter 12 digit new IP address    13 Upgrade Protocol Upgrade protocol for firmware and  configuration update  Enter    9    to toggle  between      TFTP    HTTP                   10    HandyTone 486 User Manual Grandstream Networks  Inc        16 Firmware Version Firmware version information        17 Firmware Upgrade Firmware upgrade mode  Enter    9    to rotate  among the following three options      always check     check when pre suffix changes     never upgrade          47    Direct IP Calling    When entered  user will be prompted a dial  tone  dial a 12 digit IP address to make a direct  IP call    For details  see    4 2 2 Make a Direct IP  Call        99    RESET    Enter    9    to reboot the device  or    Enter MAC address to restore factory default  settin
4.   affordability  The HandyTone 486 is fully compatible with SIP industry standard and can interoperate  with many other SIP compliant devices and software on the market     Grandstream HandyTone 486 has been awarded the Best of Show product in 2004 Internet Telephony  Conference and Expo     This document is subject to changes without notice  The latest electronic version of this user manual  can be downloaded from the following location     http   www grandstream com support ht_series ht486 documents ht486_usermanual_english pdf    CONFERENCE  amp  EXPO       HandyTone 486 User Manual Grandstream Networks  Inc     2 Installation    HandyTone 486 Analog Telephone Adaptor is an all in one VoIP integrated device designed to be a  total solution for networks providing VoIP services     The HandyTone 486 VoIP functionalities are available via a regular analog telephone     The following photo illustrates the appearance of a HandyTone 486     Top View Side Views  RJ45  ace 10M Ethernet  LAN   WAN   Phone                    5V 1200mA    RJ11 y          BUTTON P  RED LED Phone Line  GREEN LED Mafie   Interconnection Diagram of the HandyTone 486   Internet ADSL Cable  Modem Ethernet    Analog Phone  LINE PHONE  PSTN  Cordless Phone    LAN  PC PC PC  Fax    HandyTone 486 User Manual Grandstream Networks  Inc     Following are the steps to install a HandyTone 486     l   2  3     4   5     Connect a standard touch tone analog telephone  or fax machine  to PHONE port    Connect a PSTN t
5.   e registration status change  INFO level    e negotiated codec  INFO level    e Ethernet link up  INFO level    e SLIC chip exception  WARNING and ERROR levels     e memory exception  ERROR level     The Syslog uses USER facility  In addition to standard Syslog payload  it  contains the following components   GS_LOG   device MAC address  error code  error message    Here is an example  May 19 02 40 38 192 168 1 14 GS_LOG    00 0b 82 00 a1 be  000  Ethernet link is up    Grandstream implemented SIP Session Timer  The session timer extension  enables SIP sessions to be periodically    refreshed    via a re INVITE request   Once the session interval expires  if there is no refresh via a re INVITE  message  the session will be terminated     Session Expiration is the time  in seconds  at which the session is considered  timed out  if no successful session refresh transaction occurs beforehand  The    default value is 180 seconds     The minimum session expiration  in seconds   The default value is 90 seconds     27    HandyTone 486 User Manual Grandstream Networks  Inc     Caller Request  Timer    Callee Request  Timer    Force Timer    UAC Specify  Refresher    UAS Specify  Refresher    Force INVITE    Firmware Upgrade  and Provisioning    Firmware Server  Path    Config Server Path    Firmware File  Prefix    Firmware File  Postfix    Config File Prefix  Config File Postfix    Automatic Upgrade    Firmware Key    If selecting    Yes    the phone will use session timer when it
6.   law  G 723 1  G 726  G 729A B  iLBC    A user can configure Codecs in a preference list that will be included with the  same preference order in SDP message     Encoding rate for G723 codec  By default  6 3kbps rate is set     iLBC packet frame size  Default is 20ms  For Asterisk PBX  30ms might be  required     Payload type for iLBC  Default value is 97  The valid range is between 96 and  127     This enables disables the silence suppression VAD feature of G723  If set to     Yes     when a silence is detected  small quantity of VAD packets  instead of  audio packets  will be sent during this period  If set to    No     this feature is  disabled     This field contains the number of voice frames transmitted in a single packet   When setting this value  the user should be aware of the requested packet time   used in SDP message  as a result of configuring this parameter  This parameter  is associated with the first codec in the above codec Preference List or the  actual used payload type negotiated between the 2 conversation parties at run  time    e g   if the first codec is configured as G723 and the    Voice Frames per TX    is  set to be 2  then the    ptime    value in the SDP message of an INVITE request  will be 60ms because each G723 voice frame contains 30ms of audio   Similarly  if this field is set to be 2 and if the first codec chosen is G729 or  G711 or G726  then the    ptime    value in the SDP message of an INVITE  request will be 20ms    If the configured v
7.   server     If set to yes  a    user phone    parameter will be attached to the    From    header in  SIP request     This parameter decides whether the HandyTone ATA needs to send  REGISTER messages to the proxy server  The default setting is    Yes        Default is    No     If set to    Yes     the device will first send registration request to  remove previous bindings     This parameter allows the user to specify the time frequency  in minutes  the  HandyTone ATA will refresh its registration with the specified registrar  The  default interval is 60 minutes  or 1 hour   The maximum interval is 65535  minutes  about 45 days      Default is    No     Use only if proxy supports 484 response     Default is    No     When set to    Yes     the device still has a dial tone and allows  user make outgoing calls even if the device is not registered to the SIP proxy     Sets the prefix added to each dialed number     Default is 4 seconds     This parameter allows user to configure the         key to be used as the    Send      or    Dial     key  Once set to    Yes     pressing this key will immediately trigger  the sending of dialed string collected so far  If set to    No     the         key will then  be included as part of the dialed string to be sent out     This parameter defines the local SIP port the HandyTone ATA listens and  transmits  The default value is 5060     This parameter defines the local RTP RTCP port pair the HandyTone ATA  listens and transmits  It is the b
8.   weekday  1  2  3      7  for Mon  Tue      Sun   or 0 which means the daylight  saving rule is not based on week days but based on the day of the month   hour  hour  0 23     minute  minute  0 59     If    weekday    is 0  it means the date to start or end daylight saving is at  exactly the given date  In that case  the    day    value must not be negative  If     weekday    is not zero and    day    is positive  then the daylight saving starts on  the first    day   th iteration of the weekday  1st Sunday  3rd Tuesday etc   If     weekday    us not zero and    day    is negative  then the daylight saving starts  on the last    day   th iteration of the weekday  last Sunday  3rd last Tuesday  etc      The saving is in the unit of minutes  The saving time may also be preceded by  a negative     sign if subtraction is desired instead of addition     The default value for    Automatic Daylight Saving Time Rule    shall be set to     04 01 7 02 00 10  1 7 02 00 60    which is the rule for US     Examples   US Canada where daylight saving time is applicable   04 01 7 02 00 10  1 7 02 00 60   This means the daylight saving time starts from the first Sunday of April at  2AM and ends the last Sunday of October at 2AM  The saving is 60 minutes   1hour      PSTN Access Code Default is     00     User can switch the phone to PSTN line connected to the  Line port of ATA and make outgoing calls     Device Mode Default is NAT router mode  HandyTone 486 Rev 2 0 can be configured in  Bridg
9.  ATA and other VoIP Device can be connected through a router using public  or private IP addresses  with necessary port forwarding or DMZ      To make a direct IP to IP call  first pick up the analog phone or turn on the speakerphone on the analog  phone  then access the voice menu prompt by dial           or press the button on the HandyTone 286   and dials    47    to access the direct IP call menu  User will hear a voice prompt    Direct IP Calling    and  a dial tone  Enter a 12 digit target IP address to make a call  Destination ports can be specified by    66 99    using     4     encoding for        followed by the port number    Examples    If the target IP address is 192 168 0 10  the dialing convention is   Voice Prompt with option 47  then 192 168 000 010   followed by pressing the         key if it is configured as a send key or wait for more than 5 seconds   If the target IP address port is 192 168 1 20 5062  then the dialing convention would be     Voice Prompt with option 47  then 192168001020 45062 followed by pressing the         key if it is  configured as a send key or wait for 4 seconds     12    HandyTone 486 User Manual Grandstream Networks  Inc     5 2 3 Call Hold    While in conversation  pressing the    FLASH    button on the attached phone will put the remote end on  hold  Pressing the    FLASH    button again will release the previously Hold party and the bi directional  media will resume     5 2 4 Call Waiting    If call waiting feature is enabled 
10.  Inc     The password is case sensitive with a maximum length of 25 characters  The factory default password  for End User and administrator is    123    and    admin    respectively  Only administrator can get access  to    ADVANCED SETTINGS    configuration page     NOTE   e If you can not log into the configuration page by using the default password  please check with  your VoIP service provider  Most likely  the service provider has provisioned the device and    configured for you and changed the default password     After the correct password is entered into the login screen  the embedded Web server inside the device  will respond with a BASIC SETTINGS configuration page        End User This field contains the password to access the Web Configuration Menu  The  Password password is case sensitive with a maximum of 25 characters    Web Port This is the device   s internal HTTP server port  Default is 80    IP Address There are 2 modes under which the HandyTone ATA can operate       If DHCP mode is enabled  then all the field values for the Static IP mode are  not used  even though they are still saved in the Flash memory  and the IP  phone will acquire its IP address from the first DHCP server it discovers on  the LAN it attaches to     To use PPPoE feature please set the PPPoE account settings if the HandyTone  ATA is connected directly to a DSL modem  The HandyTone ATA will  attempt to establish a PPPoE session if any of the PPPoE fields are set       If Static IP mode 
11.  call progress tone frequencies  and cadences according to their country standard  By default they are set to  North American standard   Frequencies should be configured with known values to avoid uncomfortable  high pitch sounds  ON is the period of ringing     On time    in  ms     while OFF  is the period of silence  In order to set a continuous ring  OFF should be zero   Otherwise it will ring ON ms and a pause of OFF ms and then repeat the  pattern  Up to three cadences are supported     Disable Line Echo Default is No  If set to Yes  echo canceller is not used   Canceller  LEC      N    2 4 Saving the Configuration Changes    Once a change is made  users should click on the    Update    button in the Configuration page  The  HandyTone 486 will then display a screen to confirm that the changes have been saved     6 2 5 Rebooting the HandyTone 486 from remote    The user administrator of the HandyTone 486 can remotely reboot the HandyTone 486 by pressing the     Reboot    button at the bottom of the configuration page  Once done  a screen will be displayed to  indicate that rebooting is underway     6 3 Configuration through a Central Server    Grandstream HandyTone ATAs can be automatically configured from a central provisioning system     29    HandyTone 486 User Manual Grandstream Networks  Inc     When HandyTone ATA boot up  it will send TFTP or HTTP request to download configuration file      cfg000b82xxxxxx     where    000b82xxxxxx    is the MAC address of the Hand
12.  go to File   gt  Configure   gt  Security to change the TFTP server s default setting from   Receive Only    to  Transmit Only  for the firmware upgrade     4  Start the TFTP server  in the phone   s web configuration page  Configure the Firmware Server Path with the IP address of the PC  6  Update the change and reboot the unit    te    Please be advised that our client will pull out firmware from the WAN side  if the TFTP server is  connected to the device   s LAN port  the firmware upgrade will not work by design     7 2 Configuration File Download    Grandstream SIP Device can be configured via Web Interface as well as via Configuration File  through TFTP or HTTP     Config Server Path    is the TFTP or HTTP server path for configuration file   It needs to be set to a valid URL  either in FQDN or IP address format  The    Config Server Path    can  be same or different from the    Firmware Server Path        A configuration parameter is associated with each particular field in the web configuration page  A  parameter consists of a Capital letter P and 2 to 3  Could be extended to 4 in the future  digit numeric  numbers  i e   P2 is associated with    Admin Password    in the ADVANCED SETTINGS page  For a  detailed parameter list  please refer to the corresponding firmware release configuration template     When Grandstream Device boots up or reboots  it will issue request for configuration file named     C  EXXXXXXXXXXXX  Where    XXXXXXXXxxxx    is the MAC address of th
13.  makes outbound  calls if remote party supports session timer     If selecting    Yes    the phone will use session timer when it receives inbound  calls with session timer request     If selecting    Yes    the phone will use session timer even if the remote party  does not support this feature  Selecting    No    will allow the phone to enable  session timer only when the remote party support this feature    To turn off Session Timer  select    No    for Caller Request Timer  Callee  Request Timer  and Force Timer     As a Caller  select UAC to use the phone as the refresher  or UAS to use the  Callee or proxy server as the refresher     As a Callee  select UAC to use caller or proxy server as the refresher  or UAS  to use the phone as the refresher     Session Timer can be refreshed using INVITE method or UPDATE method   Select    Yes    to use INVITE method to refresh the session timer     Default method is HTTP  Firmware upgrade may take up to 10 minutes  depending on network environment  Do not interrupt the firmware upgrading  process     IP address or domain name of firmware server     IP address or domain name of configuration server     Default is blank  If configured  HT486 rev  2 0 will request the firmware file  with the prefix  This setting is useful for ITSPs  End user should keep it blank     Default is blank  End user should keep it blank     Default is blank  End user should keep it blank   Default is blank  End user should keep it blank     Choose    Yes   
14.  to enable automatic upgrade and provisioning and input the  number  in minutes  you want the HT to check for an update  When set to No   HT502 will only do upgrade once at boot up     Always check for New  Firmware at Boot up    will check for new firmware every time the device  reboots     Check New Firmware only when F W pre suffix changes    will check  for updates only when the pre suffix has been changed     For firmware encryption  It should be 32 digit in Hexadecimal Representation   End user should keep it blank     28    HandyTone 486 User Manual Grandstream Networks  Inc     Authenticate Conf Default is    No     If set to    Yes     configuration file would be authenticated    File before acceptance  End user should use default setting    Lock keypad If this parameter is set to    Yes     except for IVR MENU items 1 to 5  the  update configuration update via keypad is disabled    Allow conf SIP Default    No     If set to    Yes     user ID  authentication IP  authentication  Account password and display name can be configured in BASIC SETTINGS page    in Basic Settings   Volume Handset volume adjustment  RX is for receiving volume  TX is for  Amplification transmission volume  Default values are OdB for both parameters   6dB    generates the highest volume and  6dB generates the lowest volume     Powerline Ring This setting allows user to configure the ringing frequencies and cadences   Tone    Call Progress Tones Using these settings  users can configure various
15.  while the user is in a conversation  he will hear a special stutter tone    if there is another incoming call  User can press the flash button to put the current call party on hold  and switch to the other call  Pressing flash button toggles between two active calls     5 2 5 Call Transfer    5 2 5 1 Blind Transfer    Assuming that call party A and B are in conversation  A wants to Blind Transfer B to C     1  A presses    FLASH    on the analog phone   or Hook Flash for old model phones  to get a dial  tone    2  A dials  87 followed by C   s number  then   or wait for 4 seconds    3  A can hang up     NOTE     Enable Call Feature    has to be set to    Yes    in web configuration page   A can hold on to the phone and wait for one of the three following behaviors     e A quick confirmation tone  temporarily using the call waiting indication tone  followed by a  dial tone  This indicates the transfer is successful  transferee has received a 200 OK from  transfer target   At this point  A can either hang up or make another call     e A quick busy tone followed by a restored call  on supported platforms only   This means the  transferee has received a 4xx response for the INVITE and we will try to recover the call  The  busy tone is just to indicate to the transferor that the transfer has failed     e Busy tone keeps playing  This means we have failed to receive the second NOTIFY from the  transferee and decided to time out  Note  this does not indicate the transfer has been s
16. 6 User Manual Grandstream Networks  Inc     7 Software Upgrade    Software upgrade can be done via either TFTP or HTTP  The corresponding configuration settings are  in the ADVANCED SETTINGS configuration page     7 1 Firmware Upgrade through TFTP HTTP    To upgrade via TFTP or HTTP  the    Firmware Upgrade and Provisioning upgrade via    field  IVR  option 17  needs to be set to TFTP or HTTP  respectively     Firmware Server Path    needs to be set to a  valid URL of a TFTP or HTTP server  server name can be in either FQDN or IP address format  Here  are examples of some valid URL    e g  firmware mycompany com 6688 Grandstream 1 1 0 37   e g  72 172 83 110    NOTES     e Firmware server in IP address format can be configured via IVR  Please refer to section 5 1 for  instructions  If firmware server is in FQDN format  it must be set via web configuration  interface    e Grandstream recommends end user use the Grandstream HTTP server  Its address can be found  at http   www grandstream com firmware html  Currently the HTTP firmware server IP address  is 72 172 83 110  For large companies  we recommend to maintain their own TFTP HTTP  server for upgrade and provisioning procedures     e Once a    Firmware Server Path    and the upgrade protocol are set  user needs to update the  settings and reboot the device  If the configured firmware server is found and a new code image  is available  the HandyTone ATA will attempt to retrieve the new image files by downloading  them into t
17. HandyTone 486 User Manual Grandstream Networks  Inc   5 2 Make Phone Calls    5 2 1 Calling phone or extension numbers    There are currently two methods to make an extension number call   a  Dial the numbers directly and wait for 4 seconds  Default    No Key Entry Timeout      Or  b  Dial the numbers directly  and press    assuming that    use      as dial key is selected in web  configuration    Examples    To dial another extension on the same proxy  such as 1008  simply pick up attached phone  dial  1008 and then press the   or wait for 4 seconds    To dial a PSTN number such as 6266667890  you might need to enter in some prefix number  followed by the phone number  Please check with your VoIP service provider to get the information  If  you phone is assigned with a PSTN like number such as 6265556789  most likely you just follow the  rule to dial 16266667890 as if you were calling from a regular analog phone  followed by pressing the    or wait for 4 seconds     5 2 2 Direct IP calls    Direct IP calling allows two parties  that is  a HandyTone with an analog phone and another VoIP  Device  to talk to each other in an ad hoc fashion without a SIP proxy  This kind of VoIP calls can be  made between two parties if     e Both HandyTone ATA and other VoIP Device i e   another HandyTone ATA or Budgetone SIP  phone or other VoIP unit  have public IP addresses  or   e Both HandyTone ATA and other VoIP Device are on the same LAN using private IP addresses   or   e Both HandyTone
18. User Manual    Handy Tone 486  Analog Telephone Adaptor    For Firmware Version 1 1 0 37       Grandstream Networks  Inc   Www  grandstream  com    HandyTone 486 User Manual Grandstream Networks  Inc        Table of Contents  I WELCOME bccsecccstidechcscvccscsiesicicssdvasssasecsusetssscanscsccasasseidcveses sdecsecsecdsevaceseceasesesdassecesecdscdecs 4  Zo INSTALLATION    a ide 5  3 WHAT IS INCLUDED IN THE PACKAGE              ccccssssssssssccsscssscccssscsscssccsccssssscoeees 7  33d     SAFETY COMPLIANCES   cs cooo coo spastacstss tide E E TE A 7  Bade   WARRANTY dd Ne consort AL LASTS  Se Tee cid  E 7  4 PRODUCT OVERVIEW wiscicsccccccccscccscsiccsessaccchcecscctutescvacctetucdscsdecctsceccseseccsstesesegedetdsasees 8  Alt IRET PEA TURES a Meee oe tals Dat it BS ela Es O 8  4 2 HARDWARE SPECIFICATION         ccccccccccescecsesssesssseesssscesaceeueeeseceeecceseceeeceeseseeesssteesetseees 9  5   BASIC OPERA TIONS wissccicssscscicsiceccccdevsccavecesccccduadenacssesscvetecacevssdscecssuacedessececevetevesscced 10  5 1 GET FAMILIAR WITH KEY PAD AND VOICE PROMPT           ccsssceeeeeesesescssssceeseeeeeeeeeeess 10  O22  EMAKE PHONE  CALLES A AS Li a 12  3 2 1 Calling phone or extension numbers        scccsssccessccesseceseeeeneeesseeesnecesseeseseeenneeees 12  AA RNA A  DDS    COL LT A O  24  A O AN  PA  E AAA A A A cach veces  5 2 5 1 Blind Tras td tal  5 2 5 2 Attended  Tr iii a na A A A roaseubaanegs A ANA  3 2 6  3 way Conferencing     5 2 6 1 Star Code Style 3 way Confere
19. ance  Caller ID Scheme    Onhook Voltage    Polarity Reversal    NTP server    Send Anonymous    Anonymous Method    Time to Ring    Special Features    Grandstream Networks  Inc     This parameter specifies the mechanism to transmit DTMF digit  There are 3  modes supported  in audio which means DTMF is combined in audio signal   not very reliable with low bit rate codec   via RTP  RFC2833   or via SIP  INFO  Multiple selections of DTMF method are supported     This parameter sets the payload type for DTMF using RFC2833    Default is    No     If set to    Yes     flash will be sent as a DIMF event     The amount of time the hookflash is pressed that will cause the device to  onhook  Default is 800ms     Selects the impedance of the analog telephone connected to the Phone port     Select the Caller ID Scheme to suit the standard of different area   e Bellcore  North America    e CID Canada      DIMF Brazil   e DIMF Sewden   e DTMF  Denmark    e ETSI DTMF  Finland  Sweden    e ETSI FSK  France  Germany  Norway  Taiwan  UK CCA     The onhook voltage can be selected according to the line voltage depending on  the analog phone used  The low power high power will increase decrease the  output current  Selecting  low power  will make loop current limit   20mA   selecting  high power  make loop current limit   32mA  The default selection  is 36V  High Power      Select Polarity Reversal to adapt some call charge billing system  Default is     No        This is the URI or IP address 
20. anty              Caution  Changes or modifications to this product not expressly approved by Grandstream  or  operation of this product in any way other than as detailed by this User Manual  could void your  manufacturer warranty              Information in this document is subject to change without notice  No part of this document may be  reproduced or transmitted in any form or by any means  electronic or mechanical  for any purpose without the    express written permission of Grandstream Networks  Inc         HandyTone 486 User Manual Grandstream Networks  Inc     4 1    4 Product Overview    Key Features    Supports SIP 2 0 RFC 3261   TCP UDP IP  RTP RTCP  HTTP  ICMP  ARP RARP  DNS   DHCP  both client and server   NTP  PPPoE  STUN  TFTP  etc    Built in router  NAT  Gateway and DMZ port forwarding  Can also be configured to function  as a two Ethernet ports bridge  NAT function is disabled    Device bridge mode support   Powerful digital signal processing  DSP  to ensure superb audio quality  advanced adaptive  jitter control and packet loss concealment technology   Support various codecs including G 711  PCM a law and u law   G 723 1  5 3K 6 3K   G 726   32K   as well as G 729A and iLBC   Support Caller ID name display or block  Call waiting caller ID  Hold  Call Waiting Flash  Call  Transfer  3 way conference  on Rev  2 0   Call Forward  in band and out of band DTMF  etc   Support fax pass through  via PCMU or PCMA  and T 38 FoIP  Fax over IP    Support Silence Suppres
21. ase RTP port for channel 0  When configured   channel 0 will use this port_value for RTP and the port_value 1 for its RTCP   channel 1 will use port_value 2 for RTP and port_value 3 for its RTCP  The  default value is 5004     Default    No     If set to    Yes     the device will pick randomly generated SIP and  RTP ports  This is usually necessary when multiple HandyTone ATAs are  behind the same NAT     24    HandyTone 486 User Manual Grandstream Networks  Inc     SIP Registration  Failure Retry Wait  Time    NAT Traversal    Keep alive interval    Use NAT IP     Use STUN keep   alive to detect  networks  connectivity    Proxy Require    Subscribe for MWI     Offhook  Auto Dial    Enable Call  Features    Use Bell style  3 way Conference    Disable Call  Waiting    Disable Call   Waiting Caller ID    Retry registration if the process failed  Default is 20 seconds     This setting decides whether the NAT traversal mechanism is activated  It  should be set to    Yes    if the device is behind a NAT router  If no outbound  proxy is configured  a STUN server needs to be set to activate STUN detection  mechanism  Usually ITSP will provide these settings    If this field is set to    Yes     then the device will periodically  every Keep alive  interval  send a dummy UDP packet to the SIP server to pinhole the NAT     Default is 20 seconds  The minimum value allowed is 10 seconds  This is the  interval of sending dummy UDP packet to keep the NAT    pin hole    open     If configu
22. bring B  C in the conference    If C does not answer the call  A can press    flash    back to talk to B     Ta    5 2 6 2 Bellcore Style 3 way Conference    Bellcore style 3 way conference is also supported  To do this  user needs to enable    Use Bell style 3   way Conference    in FXS1 or FXS2 web configuration     Assuming that call party A and B are in conversation  A wants to bring C in a conference     A presses FLASH  on the analog phone  or Hook Flash for old model phones  to get a dial tone   A dials C   s number then    or wait for 4 seconds     If C answers the call  then A press    flash    to bring B  C in the conference    If C does not answer the call  A can press    flash    back to talk to B     ad E    5 2 7 PSTN Pass Through Life line    HandyTone 486 Rev  2 0 supports PSTN pass through  User can send and receive PSTN calls with the  attached analog phone     To receive PSTN calls  simply make phone off hook when the analog phone rings     14    HandyTone 486 User Manual Grandstream Networks  Inc     To make a PSTN call  press the PSTN access code   00 by default  or any number configured in web  configuration page  to switch to PSTN line and get a dial tone  then dial the PSTN number     When HandyTone 486 is out of power  it will function as a jack  User can use the same analog phone  for PSTN calls     5 3 Call Features    5 3 1 Call Features Table  star code     Following table shows the call features    code  of HandyTone 486                          
23. ccnnnnnnnncnnnononocnnnnnnnnaninnnnnnos 29   7 SOFTWARE UPGRADE iccccccsscciese dovcicscccccccedecddsconssdvcvecsscoceosassc  sssesdocvaecssescocssceseecssoeces 31  7 1 FIRMWARE UPGRADE THROUGH TFTP HTTP     ooccccnnnnccnnnnncnncccnnnnnnnncnnnnonnncnnnnnnnninocs 31  7 2 CONFIGURATION FILE DOWNLOAD    occcccnnnnccnnnncnncnncnonnnanoncnononononononaninrcnnnonanncnnonaniniss 32  7 3 FIRMWARE AND CONFIGURATION FILE PREFIX AND POSTEIX         ccccccccesssceeeceeeeeeeee 32  7 4 MANAGING FIRMWARE AND CONFIGURATION FILE DOWNLOAD   coooccccnnnnnccnncninnnionnns 32   8 RESTORE FACTORY DEFAULT SETTING           seeeeooooosssossssosssssssssssoossosesssosssssss 34    CONFIGURATION GUI INTERFACE EXAMPLES  HT 486 User Manual   http  Awww grandstream com support ht_series ht486 documents ht486_gui zip     SCREENSHOT OF LOGIN PAGE   SCREENSHOT OF STATUS PAGE   SCREENSHOT OF BASIC SETTINGS CONFIGURATION PAGE  SCREENSHOT OF ADVANCED SETTING1 CONFIGURATION PAGE  SCREENSHOT OF ADVANCED SETTING2 CONFIGURATION PAGE  SCREENSHOT OF SAVED CONFIGURATION CHANGES  SCREENSHOT OF REBOOT PAGE    A 9 Or 200 NA    HandyTone 486 User Manual Grandstream Networks  Inc     1 Welcome    Congratulations on becoming an owner of HandyTone 486  You made an excellent choice and we  hope you will enjoy all its capabilities     Grandstream s award wining HandyTone 486 is an all in one VoIP integrated access device that  features superb audio quality  rich functionalities  high level of integration  compactness and ultra 
24. different devices  Server Provider can spread the Firmware or Configuration File  download in minutes to reduce the Firmware or Provisioning Server load at any given time     33    HandyTone 486 User Manual Grandstream Networks  Inc     8 Restore Factory Default Setting    Warning        Restore the Factory Default Setting will DELETE all configuration information of the device   Please backup or print out all the settings before you approach to following steps  Grandstream will  not take any responsibility if you lose all the parameters of setting and cannot connect to your  service provider     Please disconnect network cable and power cycle the unit before trying to reset the unit to factory  default  The steps are as follows     Step 1   Find the MAC Address of the device  It is a 12 digits HEX number located on the bottom of the    unit     Step 2   Encode the MAC address  Please use the following mapping     0 9  0 9  A  22  B  222   2222  D  33  E  333  F  3333    For example  if the MAC address is 000b8200e395  it should be encoded as     0002228200333395        Step 3   To perform factory reset     Press           or the LED button for voice prompt   Enter    99    and get the voice prompt    Reset      Enter the encoded MAC address of the device   Wait for 15 seconds     aoe sf    The device will reboot automatically and restore to factory default setting     NOTE     e Please be aware by default the HandyTone 486 WAN side HTTP access is disabled  After a  factory r
25. e    Follow section 5 1 with voice menu option 01 to enable HandyTone 486 to use DHCP     6 1 2 STATIC IP Mode    Follow section 5 1 with voice menu option 01 to enable HandyTone 486 to use STATIC IP mode  then  use option 02  03  04  05 to set up IP address  Subnet Mask  Gateway  and DNS server respectively     6 1 3 Firmware Server IP Address    Follow section 5 1 with voice menu option 13 to configure the IP address of the firmware server     6 1 4 Configuration Server IP Address    Follow section 5 1 with voice menu option 14 to configure the IP address of the configuration server     6 1 5 Upgrade Protocol    Follow section 5 1 with voice menu option 15 to choose firmware and configuration upgrade protocol   User can choose between TFTP and HTTP     6 1 6 Firmware Upgrade Mode    Follow section 5 1 with voice menu option 17 to choose firmware upgrade mode among the following  three options       always check    Check when pre suffix changes    never upgrade    6 1 7 WAN Port Web Access    Follow section 5 1 with voice menu option 12 to enable WAN Port Wed Access of the device  configuration pages     17    HandyTone 486 User Manual Grandstream Networks  Inc     6 2 Configuring HandyTone 486 with Web Browser    HandyTone 486 has an embedded Web server that will respond to HTTP GET POST requests  It also  has embedded HTML pages that allow a user to configure the HandyTone 486 through a Web browser  such as Microsoft   s IE and AOL   s Netscape     6 2 1 Access the Web Con
26. e device  i e       cfg000b820102ab     The configuration file name should be in lower cases     7 3 Firmware and Configuration File Prefix and Postfix    Starting from firmware version 1 0 7 11 for HandyTone 486 Rev 2 0  adding prefix and postfix for  both firmware and configuration file is supported     Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix  and Postfix  This makes it the possible to store ALL of the firmware with different version in one  single directory  Similarly  Config File Prefix and Postfix allows device to download the configuration  file with the matching Prefix and Postfix  Thus multiple configuration files for the same device can be  stored in one directory     In addition  when the field    Check New Firmware only when F W pre suffix changes    is set to    Yes      the device will only issue firmware upgrade request if there are changes in the firmware Prefix or  Postfix     7 4 Managing Firmware and Configuration File Download    32    HandyTone 486 User Manual Grandstream Networks  Inc     When    Automatic Upgrade    is set to    Yes     Service Provider can use P193  Auto Check Interval  in  minutes  default and minimum is 60 minutes  to have the devices periodically check with either  Firmware Server or Config Server  whenever they are defined  This allows the device periodically  check if there are any new changes need to be taken on a scheduled time  By defining different  intervals in P193 for 
27. e mode so the device functions as a bridge     WAN Side HTTP Default is    No     The access to configuration page via WAN port is disabled   Access This setting has no effect if the device is in Bridge mode     20    HandyTone 486 User Manual    Reply to ICMP on  WAN port    Cloned WAN MAC  Address     LAN Subnet Mask  LAN DHCP Base IP   DHCP IP Lease  Time    DMZ IP     Port Forwarding     Grandstream Networks  Inc     Unit will not respond to PING from WAN side if set to    No        Allow user to set a specific MAC address  Set in Hex format     Sets the LAN subnet mask  Default value is 255 255 255 0  If bridge mode is  selected  the LAN settings have no effect     Base IP for the LAN port  which functions as a gateway for its LAN  Default  value is 192 168 2 1    The amount of time that a given IP address will be valid for a LAN client   Value is set in units of hours  Default value is 120hr  5 Days      Forward all WAN IP traffic to a specific IP address if no matching port is  used by HandyTone 486 itself or in the defined port forwarding     Allow user to forward a matching  TCP UDP  port to a specific LAN IP  address with a specific  TCP UDP  port     In addition to the Basic Settings configuration page  end users also have access to the device Status       page    MAC Address The device ID  in HEX format  This is very important ID for ISP  troubleshooting    WAN IP Address This field shows WAN port IP address    Product Model This field contains the product model i
28. elephone line to LINE port  optional     Insert the Ethernet cable into the WAN port of HandyTone 486 and connect the other end of  the Ethernet cable to an uplink port  a router or a modem  etc     Connect a PC to the LAN port of HandyTone 486    Insert the power adapter into the HandyTone 486 and connect it to a wall outlet     Please follow the instructions in section 6 2 1 to configure the HandyTone 486     HandyTone 486 User Manual Grandstream Networks  Inc     3 What is Included in the Package    The HandyTone 486 package contains   1  One HandyTone 486    2  One universal power adaptor  3  One Ethernet cable    3 1 Safety Compliances    The HandyTone 486 is compliant with various safety standards including FCC CE and C tick  Its  power adaptor is compliant with UL standard  The HandyTone 486 should only operate with the  universal power adaptor provided in the package     3 2 Warranty    Grandstream has a reseller agreement with our reseller customer  End users should contact the  company from whom you purchased the product for replacement  repair or refund     If you purchased the product directly from Grandstream  contact your Grandstream Sales and Service  Representative fora RMA  Return Materials Authorization  number     Grandstream reserves the right to remedy warranty policy without prior notification        Warning  Please do not attempt to use a different power adaptor  Using other power adaptor may  damage the HandyTone 486 and will void the manufacturer warr
29. ensing     FE CE       HandyTone 486 has two hardware revisions  This information can be found on the label at the  bottom of the device  The difference between HandyTone 486 Rev 1 0 and HandyTone 486  Rev 2 0 is that a HandyTone 486 Rev 2 0 line port can function as PSTN pass through while a  HandyTone 486  Rev 1 0  old model  no longer shipped  line port is just a life line port and will  bridge to PSTN only when the device is out of power     HandyTone 486 User Manual Grandstream Networks  Inc     5 Basic Operations  5 1 Get Familiar with Key Pad and Voice Prompt    HandyTone 486 stores a voice prompt menu  Interactive Voice Response or IVR  for quick browsing  and simple configuration  To enter this voice prompt menu  simply press the button on the  HandyTone 486 or pick up the phone and dial            The following table shows how to use the voice  prompt menu to configure the device                                         Menu Voice Prompt User   s Options  Main Menu      Enter a Menu Option    Enter        for the next menu option  Enter         to return to the main menu  Enter 01     06  47  86 or 99 Menu option  01    DHCP Mode     or Enter    9    to toggle the selection      Static IP Mode    If user selects    Static IP Mode     user need  configure all the IP address information  through menu 02 to O5  If user selects     Dynamic IP Mode     the device will retrieve  all IP address information from DHCP server  automatically when user reboots the device    02  
30. eset  the device   s web configuration page can be accessed only from its LAN port   please refer to instructions in section 6 2 1 for details     34    
31. figuration Menu    HandyTone 486   s web configuration page can be accessed via LAN or WAN port   e From the LAN port       Directly connect a computer to the LAN port      Open a command window on the computer     Type in    ipconfig  release     the IP address etc  become 0 0 0 0      Type in    ipconfig  renew     the computer gets an IP address in 192 168 2 1 by default     Open a web browser  type in the default gateway IP address  You will see the login  page of the device     http   192 168 2 1  e From the WAN port   The WAN port HTML configuration option is disabled by default from factory  To access the  HTML configuration menu from the WAN port  first enable the    WAN side HTTP access    option  via IVR option 12  With the WAN side HTTP access enabled  then get the WAN IP address of the  HandyTone 486 through section 5 1 with menu option 02  The HandyTone 486   s Web  Configuration page can be accessed by the following URI via WAN port   http   HandyTone IP Address  where the HandyTone IP Address is the WAN IP address of the HandyTone 486   NOTE   e To type IP address into browser to get into the configuration page  please strip out the leading       0   s as the browser will parse in octet  e g   1f the IP address is  192 168 001 014  please type in   192 168 1 14     6 2 2 End User Configuration    Once this request is entered and sent from a Web browser  the HandyTone 486 will respond with a  login screen     18    HandyTone 486 User Manual Grandstream Networks 
32. g  For details  see section 8                        Invalid Entry    Automatically returns to Main Menu       IVR supports error reporting when the following problems occur  User will hear silence when picking  up the handset  After pressing      user will hear one or more error codes listed below  User may hear  one or more error codes depending on errors detected such as E104E103E  Upon hearing error code   user can press   to get into the  VR main menu                                El01E Ethernet link down  E102E No IP address obtained  DHCP or PPPoE mode   E103E Device is not registered to SIP server  E104E Provisioning in action  El0SE No STUN responses  NOTES     Once the LED button is pressed  it enters voice prompt main menu  If the button is pressed  again while it is already in the voice prompt menu state  it jumps to    Direct IP Calling    option  and dial tone plays in this state           shifts down to the next menu option           returns to the main menu      9    functions as the ENTER key in many cases to confirm an option   All entered digit sequences have known lengths   2 digits for menu option and 12 digits for IP  address  Once all digits are accumulated  the device will automatically process them   For IP address input  omit the dot and enter the digits directly  add O for those octets with less  than three digits  e g   IP  192 168 1 10  key in  192168001010   Key entry cannot be deleted but the phone may prompt error once it is detected    11    
33. he HandyTone ATA   s SRAM  During this stage  the HandyTone ATA   s LEDs will  blink until the checking downloading process is completed  Upon verification of checksum  the  new code image will then be saved into the Flash  If TFTP HTTP fails for any reason  e g    TFTP HTTP server is not responding  there are no code image files available for upgrade  or  checksum test fails  etc   the HandyTone ATA will stop the TFTP HTTP process and simply  boot using the existing code image in the flash    e Firmware upgrade may take as long as 1 to 20 minutes over Internet  or just 20  seconds if it is  performed on a LAN  It is recommended to conduct firmware upgrade in a controlled LAN  environment if possible  For users who do not have a local firmware upgrade server   Grandstream provides a NAT friendly TFTP server on the public Internet for firmware upgrade   Please check the Services section of Grandstream   s Web site to obtain our public TFTP  server   s IP address    e Alternatively  user can download a free TFTP or HTTP server and conduct local firmware  upgrade  A free windows version TFTP server is available for download from    http   support solarwinds net updates New customerFree cfm     Instructions to download a free TFTP Server     1  Unzip the file and put all of them under the root directory of the TFTP server   31    HandyTone 486 User Manual Grandstream Networks  Inc     2  Put the PC running the TFTP server and the HT486 device in the same LAN segment     3  Please
34. is selected  then the IP address  Subnet Mask  Default  Router IP address  DNS Server    primary   DNS Server 2  secondary  fields  will need to be configured  These fields are set to zero by default     DHCP hostname This option specifies the name of the client  This field is optional but may be  required by some Internet Service Providers  Default is blank     DHCP domain This option specifies the domain name that client should use when resolving  hostnames via the Domain Name System  Default is blank     DHCP vendor class This option is used by clients and servers to exchange vendor specific  ID information  Default is blank     PPPoE account ID PPPoE username  Fill this field if your ISP requires you to use a PPPoE   Point to Point Protocol over Ethernet  connection     PPPoE password PPPoE account password     19    HandyTone 486 User Manual Grandstream Networks  Inc     Time Zone This parameters decides how the displayed date time will be adjusted  according to the specified time zone     Daylight Savings This parameter controls whether the displayed time will be daylight savings  Time time or not  If set to    Yes    and the Optional Rule is empty  then the displayed  time will be 1 hour ahead of normal time     The    Automatic Daylight Saving Time Rule    shall have the following syntax   start time end time saving   Both  start time and end time have the same syntax   month day weekday hour minute   month  1 2 3    12  for Jan  Feb      Dec    day    l  1 2 3    31 
35. n Password Administrator password  Only administrator can configure the    Advanced  Settings    page  Password field is purposely left blank for security reason after  user clicks UPDATE button  This field is case sensitive and the maximum  password length is 25 characters     SIP Server IP address or Domain name provided by VoIP service provider    IP address or Domain name of Outbound Proxy  or Media Gateway  or Session   Outbound Proxy Border Controller  Used by ATA for firewall or NAT penetration in different  network environment  If symmetric NAT is detected  STUN will not work and  ONLY outbound proxy will provide solution for it     SIP User ID User account information  provided by VoIP service provider  ITSP   usually  has the form of digit similar to phone number or actually a phone number    Authenticate ID ID used for authentication  usually same as SIP user ID  but could be different  and decided by ITSP    Authentication Account information  password for ATA to register to  SIP  servers of ITSP    Password   Name SIP service subscriber   s name which will be used for Caller ID display    Home NPA Local area code for North American Dial Plan     22    HandyTone 486 User Manual Grandstream Networks  Inc     Preferred Vocoder    G723 Rate     iLBC frame size     iLBC payload type     Silence Suppression    Voice Frames per  TX    Fax Mode   Layer 3 QoS  Layer 2 QoS   VoIP    Layer 2 QoS   PC     The HandyTone ATA supports 6 different codec types including G 711 A U
36. nce     5 2 6 2     Bellcore Style 3 way  Conference scc ccccesiczcsncssssessessevessvesesnseidesevasscebecesiacetotebtssugvesssnues ORRERA  5 2 7 ABS EN Pass ANTONI  213  CALE FEATURES AE EE E A AA  5 3 1 Call Features Table  star code   O O A OE a ae eal Mie a td entice 8 toca tt be ae lee  JD  LED LIGHT  PATTERN  INDICATION A ias  6 CONFIGURATION GUIDE           ssoeeesscossssssssssossossosssocoesocossoossssossssoosesosossssssessesssssoss 17  6 1 CONFIGURING HANDYTONE 486 THROUGH VOICE PROMPT              00 eesscesseceeeeeeeeess 17  OLLE DAHCP MoOdE   lt  lt  dados 17  G e  STAEIC IP Mode ete cea ca ot esl testicals aes tte IN eke 17  6 1 3 Firmware Server IP Address neinean a a N 17  6 1 4 Configuration Server IP Address iii 17  6 1 5 Upgrade Protocol  a 17  6 1 6 Firmware Upgrade Mode ia 17  6 1 7 WAN Port Web ACCES S viccccccscccccccccccccccccccccscsssssssccccessscsssssussssussssscesseeessssssuususeenss 17  6 2 CONFIGURING HANDYTONE 486 WITH WEB BROWSER    occcccoccconnnnonononnncnoncncncnnncnonos 18  6 2 1 Access the Web Configuration Menu        scccssccsssccesnccesneeseneeesseeesneceeseeesneeeneneees 18    HandyTone 486 User Manual Grandstream Networks  Inc     6 2 2 End User Configuration saccsvaviavaviesedadssstenstatbantesansaozacdedatinssteanieaesontaadedediocesieieee 18  6 2 3 Advanced User ii 22  6 2 4 Saving the Configuration Changes ss iii 29  6 2 5  Rebooting the HandyTone 486 from remote sossen 29   6 3 CONFIGURATION THROUGH A CENTRAL SERVER  cooocccccnnnn
37. nfo  such as HT486 Rev 2 0    Software Version    System Uptime    Registered    PPPoE Link Up    NAT    Program  This is the main software release  This number is always used for  firmware upgrade  Current release is 1 0 8 32    Bootloader  current version is 1 0 8 11    HTML  current version 1 0 8 32    VOC  current version is 1 0 0 12    This shows how long the device has been up since the last reboot   This shows whether the unit is registered to service provider   s server or not   This field shows whether the PPPoE connection is up if the HandyTone    ATA is connected to DSL modem     This shows what kind NAT the HandyTone ATA is connected to via its  WAN port  It is based on STUN protocol     21    HandyTone 486 User Manual Grandstream Networks  Inc     NAT Mapped IP WAN side public IP if connected to LAN of a SOHO router   NAT Mapped Port WAN side SIP port if connected to LAN of a SOHO router     Other Statistical Self explainable  please see the page displayed   Status of ATA    6 2 3 Advanced User Configuration    To login to the Advanced User Configuration page  please follow the instructions in section 6 2 1 to  get to the following login page  The password is case sensitive and the factory default password for  Advanced User is    admin        Advanced User configuration includes not only the end user configuration  but also advanced  configuration such as SIP configuration  Codec selection  NAT Traversal Setting and other  miscellaneous configuration        Admi
38. of the NTP  Network Time Protocol  server   which the HandyTone ATA will use to synchronize the date time     If this parameter is set to    Yes     user ID will be sent as anonymous  essentially  blocks the Caller ID from displaying     If it is set to    Use from header     Callers    SIP user ID will be sent as  anonymous  essentially block the Caller ID from displaying  If it is set to    User  privacy header     the SIP INVITE message contains a    privacy    header  and the  server blocks the caller ID from the called party     The duration of ringing when a call is not answered  Default is 60 seconds     Default is Standard  Choose the selection to meet some special requirements  from Soft Switch vendors like Nortel  Broadsoft  etc     26    HandyTone 486 User Manual Grandstream Networks  Inc     CBCOM Encode    CBCOM Encoder  1 1 Key    Syslog Server    Syslog Level    Session Expiration    Min SE    SIP  RT C P and T 38 modes  1 0 and 1 1    Key to be used by CBCOM    The IP address or URL of System log server  This feature is especially useful  for ITSP  Internet Telephone Service Provider      Select the ATA to report the log level  Default is NONE  The level is one of  DEBUG  INFO  WARNING or ERROR  Syslog messages are sent based on  the following events     e product model version on boot up  INFO level    e NAT related info  INFO level    e sentor received SIP message  DEBUG level    e SIP message summary  INFO level    e inbound and outbound calls  INFO level  
39. oice frames per TX exceeds the maximum allowed value  the  HandyTone ATA will use and save the maximum allowed value for the  corresponding first codec choice  The maximum value for PCM is 10 x10ms   frames  For G726  it is 20  x10ms  frames  And 32  x30ms  and 64  x10ms   frames for G723 and G729 respectively     T 38  Auto Detect  FoIP by default  or Fax Pass Through     This field defines the layer 3 QoS parameter which can be the value used for IP  Precedence or Diff Serv or MPLS  Default value is 48     Layer 2 QoS settings for VoIP traffic  Default setting is blank  VLAN  supported equipment is required if user needs to change these settings     Layer 2 QoS settings for LAN port device traffic  Default setting is blank   VLAN supported equipment is required if user needs to change these settings     23    HandyTone 486 User Manual Grandstream Networks  Inc     Allow incoming SIP  messages from SIP  proxy only    Use DNS SRV     User ID is Phone  Number    SIP Registration    Unregister on  Reboot    Register Expiration    Early Dial    Allow outgoing call  without  Registration    Dial Plan Prefix    No Key Entry  timeout    Use   as  Send Key    Local SIP port    Local RTP port    Use Random Port    If set to    Yes     the device will ignore any SIP message that does not come from  the IP address  Source IP in the IP header  that it is registered to  Default  setting is    No        Default is    No     If set to    Yes    the client will use DNS SRV to lookup for the
40. red  the NAT IP address will be used in SIP SDP message  Default is  blank     Use STUN keep alive to detect WAN side network problems  If keep alive  request does not yield any response for configured number of times  the device  will restart the TCP IP stack  If the STUN server does not respond when the  device boots up  the feature is disabled     SIP Extension to notify SIP server that the unit is behind the NAT Firewall     Default is    No     When set to    Yes    a SUBSCRIBE for Message Waiting  Indication will be sent periodically     This parameter allows a user to configure a User ID or extension number to be  automatically dialed upon offhook  Please note that only the user part of a SIP  address needs to be entered here  The HandyTone ATA will automatically  append the    O    and the host portion of the corresponding SIP address    Note  Please write down the IP address of the ATA if you use this feature as it  will prevent you to access the IVR and the only way to access the device  configuration is via the web configuration page     Default is    Yes     Advanced call features using start codes are supported  locally     If this parameter is set to    Yes     user will be able to make Bellcore style 3 way  conference   23 will be disabled     Default is    No     User can use star codes to enable disable call waiting     Default is    No        25    HandyTone 486 User Manual    Send DTMF    DTMF Payload  Type    Send Flash Event  Onhook Threshold    FXS Imped
41. sion  VAD  Voice Activity Detection   CNG  Comfort Noise  Generation   Line Echo Cancellation  G 168   and AGC  Automatic Gain Control    Support standard encryption and authentication  DIGEST using MD5 and MD5 sess   Support for Layer 2  802 1Q VLAN  802 1p  and Layer 3 QoS  ToS  DiffServ  MPLS   Support automated NAT traversal without manual manipulation of firewall NAT   Support device configuration via built in IVR  Web browser or encrypted configuration files  through TFTP or HTTP server   Support firmware upgrade via TFTP or HTTP   Support PSTN pass through  on Rev 2 0    Support SIP Session Timer   Support Syslog  on Rev 2 0    Support volume amplification   Support configurable Call Progress Tones   Ultra compact  wallet size  and lightweight design  great companion for travelers   Compact  lightweight Universal Power adapter    HandyTone 486 User Manual    4 2    Grandstream Networks  Inc     Hardware Specification    The table below lists the hardware specification of HandyTone 486     Model    LAN interface  WAN interface  FXS telephone port  PSTN port   Button   LED    Universal Switching  Power Adaptor  Dimension   Weight  Temperature    Humidity    Compliance    NOTE     HandyTone 486    1xRJ45 10Base T   1xRJ45 10Base T   1xFXS   1x PSTN pass through or life line port  1   Green and red color    Input  100 240V AC 50 60 Hz  Output   5 VDC  1200mA   UL certified   70mm  W    130mm  D    27mm  H    0 6lbs  0 3kg    40   130  F   5     45  C   10    90    non cond
42. uccessful   nor does it indicate the transfer has failed  When transferee is a client that does not support the  second NOTIFY  such as our own earlier firmware   this will be the case  In bad network  scenarios  this could also happen  although the transfer may have been completed successfully     5 2 5 2 Attended Transfer    13    HandyTone 486 User Manual Grandstream Networks  Inc     Assuming that call party A and B are in conversation  A wants to Attend Transfer B to C     1  A presses    FLASH    on the analog phone  or Hook Flash for old model phones  to get a dial  tone   2  A then dial C   s number followed by    or wait for 4 seconds     3  IfC answers the call  A and C are in conversation  Then A can hang up to complete transfer    4  IfC does not answer the call  A can press    FLASH    back to talk to B     NOTE     e When Attended Transfer failed and A hang up  HandyTone  486 will ring user A back again to  remind A that B is still on the call  A can pick up the phone to restore conversation with B     5 2 6 3 way Conferencing    HandyTone 496 supports 3 way conference in two styles  star code style or Bellcore style     5 2 6 1 Star Code Style 3 way Conference    Assuming that call party A and B are in conversation  A wants to bring C in a conference     A presses FLASH  on the analog phone  or Hook Flash for old model phones  to get a dial tone   A dials  23 then C   s number then    or wait for 4 seconds     If C answers the call  then A press    flash    to 
43. yTone ATA     The configuration files can be downloaded via TFTP or HTTP from the central server  A service  provider or an enterprise with large deployment of HandyTone ATA can easily manage the  configuration and service provisioning of individual devices remotely from a central server     Grandstream has a provisioning system called GAPS  Grandstream Automated Provisioning System   that is used to support automated configuration of Grandstream devices  GAPS uses enhanced  NAT  friendly  TFTP or HTTP  thus no NAT issues  and other communication protocols to communicate  with each individual Grandstream device for firmware upgrade  remote reboot  etc     Grandstream provides GAPS service to VoIP service providers  Use GAPS for either simple  redirection or with certain special provisioning settings  At boot up  Grandstream devices by default  point to Grandstream provisioning server GAPS  based on the unique MAC address of each device   GAPS provision the devices with redirection settings so that they will be redirected to customer   s  TFTP or HTTP server for further provisioning  Grandstream also provide GAPSLite software package  which contains our NAT friendly TFTP server and a configuration tool to facilitate the task of  generating device configuration files     The GAPSLite configuration tool is now free to end users  The tool and configuration template are  available for download from http   www grandstream com support configurationtool html        30    HandyTone 48
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
StarTech.com INSERTVIDF coaxial connector  Bedienungsanleitung  =waud - Tannay  Bravo AutoPrinter Manual  AutoTrac Raven User Guide.fm  Fortecortín 40 mg solución inyectable  MANUAL FRANCÈS FILM.CDR  Descargar ficha técnica  ハードウェアマニュアル - 株式会社PALTEK  AAPS User`s Manual - Campbell Company Pedestrian Safety    Copyright © All rights reserved. 