Home
User Manual - TPC Advanced Technology
Contents
1. to TPC Advanced Technology 851 S Lawson St City Of Industry CA 91748 Or Email a scaned copy to service tpcdental com
2. IP User Manual map C LED 5 5 N Cordless LED Curing Light e LED55N must be installed and operated by a qualified dental professional e All instructions in this USERS MANUAL must be completely read before installation or operation e The user should wear colored protective glasses to avoid eye injury by the LED light REV 1 1 13 Table Of Contents 1 INTRODUCTION 1 1 TECHNICAL INFORMATION 2 FEATURES 3 ACCESSORIES 4 INSTALLATION 5 OPERATION 6 MAINTENANCE 7 TROUBLESHOOTING 8 WARRANTY 1 INTRODUCTION Thank you for purchasing the LED 55N LED curing light The LED 55N is a dental curing light which uses the latest LED technology to polymerize composite resin Caution A Attention Important information is being presented Refer to the Operators Manual for more informa tion A High intensity Light Protect your eyes from the light generated by this product X Shock Hazard Beware of electrical shock or injurv Tvpe B Applied Part im Class II Medical Equipment X Electronics Waste Properly dispose of when use is discontinued 1 1 Technical Information Range of Light in nm 430 490 nm Light Intensity at the Tip mW cm2 1200 mW Battery Life 200 cycles at STANDARD mode 10 seconds per cycle 135 cycles at STANDARD mode 20 seconds per cycle Charging Time to Complete 5 Hours Battery Type Lithium Ion Cradle Battery Rechargeable Operating Temperature 15 30 C 60 86 F Unit turn
3. e Light guide had debris on it Clean light guide base illuminates red when checking Not enough battery power to cure Charge battery the light intensity When i try to attach the battery its Battery may have been dropped very tight and will not fully attach and the threads are dented in is being used Warranty Information All of our products sold are guaranteed to be free from defects in workmanship and materials for a 1 year from date of purchase unless otherwise stated TPC will repair or replace any defective part at no charge During the warranty period TPC will not be responsible for labor charges or shipping charges to from the TPC facility This guarantee does not cover normal wear or stains on surface finish The guarantee does not cover damage resulting from improper installation or misuse All claims against the freight carrier must be initiated at the time the damaged items are received The claim is the responsibility of the customer We are improving our products on a continuous basis We reserve the right to make modifications without the need for prior notification and are not obligated to modify previously manufactured items Light guides and batteries are not covered under any type of warranty Name Address City CC States Zip Phone Number FAX Email Address Model LED 55N Handpiece SN Base SN Please complete this card and return it to TPC Include a copy of your invoice or packing slip Return
4. gh indicates that there is not suffcient power to cure Possible reasons for a red light are Low battery Damaged dirty light guide or damaged LED 5 Operation A Set Curing Program Press and hold the function switch for two seconds and you will see the modes change every second To stop on the desired mode simply let go of the depressed button for the desired mode 1 FAST FI 2 PULSE JUL Function 3 RAMP 71 Button 1 Curing Time 2 Battery Sign 3 Curing Program B Set Timer The LED55N has a fixed curing time of 20 seconds The light will beep at 10 seconds and then automatically stop the curing process at 20 seconds C Start to Operate Press button to start curing program To interrupt a program press curing button again When the program finishes the curing light handpiece will beep again then turn off the light immediately D Turn off the Power Allow curing light handpiece to enter into sleeping mode automatically This will shut down all the curing func tion to save the power To completely shut down curing light disconnect battery 6 MAINTENANCE Be sure there is no resin or material sticking to the surface of the light guide pi 2 If materials are sticking on the light guide immediately clean it with soft cloth Keep light guide clean for better light intensity and curing performance 3 The light guide should be sterilized after each use It can be safely autoclaved at 121 C F
5. o the back of the handpiece and turn clockwise to fasten Be sure not to over tighten the battery to the handpiece Step 5 Install light guide into the handpiece Directly insert it onto the front of the curing light handpiece The light guide can be rotated after installation Step 6 Place the light shield over the light guide Verify it is secure on the silver chuck of light guide 3 4 Installation E Connect power adaptor to the charging base sA Attach battery to light handpiece 4 1 Charging Base 1 Light intensity tester indicator 2 Battery Charging indicator A Remove protective battery Covers 1 Insert light guide 3 Light intensity Place batteries in the charging base Attach light shield Charging base indicators 1 light intensity sensor Place the light guide on this sensor to verify there is sufficient light to cure If there is sufficient light and battery power the light sensor will illuminate purple If there is not sufficient light power or the light guide is damaged or dirty the light indicator will illuminate red 2 Battery charging indicators When flahing red the batteries are charging When the light is solid green the batteries are fully charged 3 light sensor indicator This light is only activted when the light intensity sensor is being used A purple light indicates that there is sufficient power to cure A red li
6. or no more then 15 minutes Let cool before handling 4 The other accessories such as curing light hadpiece and eye protector should be scrubbed with pure water and sheathed in accordance with standard disinfection procedures 5 Keep curing light handpiece in charging station while not in use 6 Dispose Lithium battery according to the federal and state laws 7 The User should wear colored protection glasses to avoid eye injury due to LED light 7 TROUBLESHOOTING The low battery indicator on the Battery Low Charge Battery curing light is solid red The overheat indicator light is The curing light has overheated Allow to cool for 10 min orange When the light is placed on the Battery is very low Disconnect battery and charge bat charging base the LED emmits a tery while disconnected from light low light while not in use for 10 min or till fully charged My light guide is very loose when O ring damaged or missing Check o ring or repalce placed in the curing light The light changes modes on its own Function button is depressed in Verify the function button is not stuck Press and release the func tion button None of the mode or status lights Drained battery Charge battery are illuminating Contacts are dirty on the battery Clean contacts Depleted battery Replace battery Charging base does not beep when No power to base Connect power supply to base batteries are placed on the charger The light intensity indocator on th
7. s off automatically when the temperature at the wand tip reaches 48 C Power Input Curing Light 52 VDC 1 0A Power Input Power Supply 90 240 VAC 50 60 Hz Pulse Rate 10 Hz Pulse Duty Cycle 50 Storage and Transport Conditions 0 40 C 32 104 F 0 100 RH 1000 to 9000 meters elevation 2 FEATURES 1 Latest LED technology 2 Minimal heat output 3 Three preset programs 1 FAST Full power output JUL PULSE 0 5 second intermittent output FI RAMP Soft Start 4 Timer The Led 55N has a fixed timer The unit will cure for a total of 20 seconds At 10 seconds the light will beep indicating that you have reached the 10 second time mark At 20 seconds the light will beep again and automatically stop the curing process 5 Built in light intensity sensor The led 55N base has the a built in light intensity sensor on the charging base This will allow the end user to verify if there is sufficient power to cure materials To verify light intensity you must use a LED light radiometer 6 Sleeping Mode The LED 55N will be in trickle charging mode after 3 min of non use Trickle charging mode only applies if the handpiece is placed on the charging base If left off of charging base the light will be in sleep mode 7 Auto Memory LED 55N will remain in previous setting including the curing time and the curing program 8 Cordless The LED 55N comes with two re chargable lithium ion Batteries once one ba
8. ttery is drained you may switch to the other battery that will be fullly charged if it has been placed on the charging base lil F 9 Low Battery Over Heat indicator The low battery indicator light will illuminate red when the battery does not have sufficiant power to operate the light The over heat light will illuminate yellow if the handpiece has over heated If the light over heats allow the light to rest for 10 min When the light is illuminated green the light has sufficient power to cure 3 Accessories 1 Curing Light Handpiece 2 Charging Base 3 Oval Protector 4 Light guide PN LED55HP LED55Base PN P219 PN P109 5 Switching Power Adapter 6 Function Switch 7 Battery PN LED55N TF PN LED55 BTN PN LED55 BATT 4 Installation Step 1 Connect Power Adapter to charging base Step 2 Remove protective battery contact covers Step 3 Place the batteries in the charging base Allow the batteries to fully charge For the best performance charge curing light handpiece continually for 4 hours charge battery at least 8 hours for first time using The battery indicator on the charging base will show the sign of full power when battery is fully charged LED 55N will detect the charging automatically There will be one short beep tone generated when it has been properly put on to the Charging Base Step 4 After charging is complete attach one battery to the handpiece Align the threads of the battery t
Download Pdf Manuals
Related Search
Related Contents
Driving Locomotives UTILISA TION ET SÉCURITÉ PaperCut MF - Toshiba SDK2 Embedded Manual ダウンロード VisionTek 900696 USB powered storage enclosure Télécharger "Dossier de presse" AP ショップスツール Outdoor Fireplace Copyright © All rights reserved.
Failed to retrieve file