Home

USER`S MANUAL - Bendigo Security

image

Contents

1. The factory default Master Code is 123 NESS D16 V4 5 CONTROL PANEL USER MANUAL PROGRAMMING PROGRAMMING OPTIONS TABLE OPTION OPTION No User Code 1 Master Code P11E User Code 2 FACTORY DEFAULT 123 RANGE PROGRAMMED 3 to 6 digits 3 to 6 digits User Code 3 3 to 6 digits User Code 4 3 to 6 digits User Code 5 User Code 6 3 to 6 digits User Code 7 User Code 8 User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14 User Code 15 Entry Delay 1 20 seconds 3 to 6 digits 1 to 99 sec Entry Delay 2 60 seconds 10 to 990 sec Exit Delay 60 seconds 1 to 99 sec Follow Me Telephone No NOTE The Entry Delay 2 timer programs in 10 second intervals Example if a value of 6 is programmed the time is 60 seconds Up to 15 digits a 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits Le NESS D16 V4 5 CONTROL PANEL USER MANUAL PROGRAMMING Programming USER CODES Press P Master Code E ado Enters Program Mode The PROGRAM light will be on Press CP Option No E Ka The two digit option number for the code to be programmed The existing code if any will be displayed SHE Press NEW coofj E NEW CODEJ E Enter the new code twice The new code will be
2. The control panel must be Armed prior to vacating the premises in order to detect intruders The panel must be disarmed and not in Program Monitor Memory or Exclude modes Note If the panel is already in alarm you must first silence the alarm before you can Arm If something is wrong when Arming the control panel the normal 3 beeps will besreplaced by other warnings J J110 L 10 beeps means Mains Power is turned off or the Backup Battery is low JI One long beep indicates an invalid entry or an alarm is outstanding and needs to be reset by entering your User Code first NOTE ARM ONLY codes SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds as a warning to indicate that those zones have been automatically excluded For maximum security you should return Disarm check the premises and then Arm again Continual warnings could mean that a detector is faulty and may have to be manually excluded If the auto exclude option is disabled the siren will sound for the duration of reset time if a zone is Unsealed at the end of exit time Normal user codes can arm the panel only if it is fully disarmed first User codes that are programmed to be Arm Only codes can arm the panel from Monitor mode or from the disarmed state See page 20 for User Code Programming NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION DISARMING O E
3. reatar 12 Keypad Duress seara 12 Keypad Fire Alarm m seen 13 Keypad Medical Alarm ceee 13 Excluding Zongs2 e 14 View Mem nanana 15 RADIO KEY OPERATION 16 MONITORING OPERATION oscene 17 PROGRAMMING 18 Programming Options Table 19 User Code programming 20 Entry Exit Timer programming 21 Telephone Number programming 21 Remote Operation by Telephone 22 23 Ness Accessories aeee 24 25 Troubleshooting 26 Installation Record 27 OPERATION SUMMARY 28 NESS D16 FEATURES 8 or 16 Fully programmable zones Any combination of 8 or 16 hardwire or radio zones Full radio supervision Contact ID Dialler Format Ultra Modern and Impact resistant Housing Ness Audible Dialler Format Follow Me Audible Dialler Option Separate 24 Hour Tamper input Single or Double Trigger Zones Remote LCD Keypads Max 3 Fully programmable via the system Keypad Eliminates the need for expensive programmers or Proms Inbuilt Vibration Sensor Analyser All programming data is permanently stored in a non volatile EEprom memory True Dynamic Battery Test every time the Panel is Armed Disarmed and every hour Area Partitionable 2 Areas Any Zone can be programmed to any area as well as common areas Comes complete with an AC plug p
4. OPERATION SUMMARY OPERATION LCD KEYPAD Arming Shortcut ARM E must be ON P62E 5E The panel must be in a Disarmed state first s User Code E DISARM To Disarm and or reset User Code E alarms Monitor Shortcut MONITOR MODE Miette ON PE E The panel must be in P 7 Press OFF button twice within 4 seconds a Disarmed state first Or User Code E or ONSDhen twice within 4 seconds P69E 5E must be ON C D CD Both keys together C 0 User Code E 0r Cx finas ONA Press and hold for 4 seconds P68E 3E amp 4E must be OFF KEYPAD DURESS 5 6 8 or 9 User Code E Keypad Duress is factory To Disarm and report a Duress Alarm add any set for silent reporting of the digits 5 6 8 or 9 before the User Code when Disarming P75E1E must be enabled Exclude Shortcut EXCLUDING ZONES Eco E ale ON POZE 2E EXCLUDE ENTER can only be used when the panel is Or User Code E disarmed q Q Zone No E Enter the zone numbers EXCLUDE CODE ENTER Zone No E to be Excluded can be used when the panel f is armed or disarmed CE To exit Exclude mode Memory Shortcut VIEW MEMORY GFEMORY Genoe E must be ON P62E 1E View Memory can only be used when the panel is Or User Code E di d Ea Press repeatedly to display the last 30 events E To exit Memory mode NOTE ON ARMING Normal user codes can arm the panel only if it is fully disarmed first Us
5. POSSIBLE CAUSE One or more Zone Detection Devices e g PIR Reed Switch may be Unsealed REMEDY Close door or window find the cause of movement 10 beeps from keypad MAINS light flashing BATTERY light flashing The mains power may be off The backup battery may be low A Radio Device battery may be low Make sure the plug pack is plugged in and the power point id turned on Replace the backup battery Call your installer 1 long beep from keypad Invalid keypad entry Press E button and try again 2 second siren at the end of Exit Delay time A zone was Unsealed at the end of Exit Delay time Disarm the panel and check all zones Strobe light is flashing There has been an alarm Reset the alarm by Disarming the panehand check the Alarm Memory Siren sounds while the panel is Disarmed A 24 hour zone has been triggered E g Siren Tamper Box Tamper Panic Button Reset the alarm by Disarming the panel and call your installer EXCLUDE light is flashing A zone s has been Excluded TAMPER light flashing The 24 hour Tamper input has triggered Call your installer ALARM MEMORY light is flashing There are alarms in memory To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you Arm the panel Cannot enter Program Mode The panel is Armed Only the Master Code can enter Program Mode Disarm the panel before
6. areas of your premises where an intruder may enter or trespass Another detection device used is called a Reed Switch Reed Switches are attached to windows and doors to detect if a window or door has been opened A Reed Switch consists of a magnet which is normally attached to the moving part of a window or door and the Reed switch which mounts to the door or window frame The panel is Armed when it is set to detect an intruder At other times it is Disarmed Normally a zone is considered Sealed Activation of a detection device will cause the zone to be Unsealed and may cause an alarm Detectors such as fire detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setting A zone with this assignment is called a 24 hour zone Some detection devices may be required to generate an alarm or warning only when the panel is Disarmed A zone with this assignment is called a Day zone Before leaving the premises you must Arm the panel to enable it to detect intruders and generate an alarm After arming the panel will ignore detectors during the Exit Delay Time to enable you to depart without triggering an alarm Arming the system may be done through the keypad or with the use of optional Radio Keys for Arming by remote control from outside the premises When you enter the premises the panel will ignore selected zones for the Entry Delay Time and will not alarm unless you don
7. Exclude IS not permanent Excluded zones are automatically INCLUDED next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the ZONE NUMBER E sequence to turn OFF the zone lights to be Included e EXCLUDE E works only when the panel is Disarmed EXCLUDE User Code E works in any state e EXCLUDE User Code E can only exclude the zones in the Area assigned to that code NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION VIEWING MEMORY Press E Or User Code E a The M MEMORY icon will turn on Press The most recent event will be displayed Press The next most recent event will be displayed Press and so on up to 30 events O Press E to exit Memory mode The D16 Control Panel stores a comprehensive event memory including Arming Disarming Low Battery Mains Fail and Alarms The memory is constantly upgraded and the last 30 events are always available for viewing This memory display can only be selected while the panel is in the Disarmed state TO lt GLEAR THE MEMORY LIGHT The MEMORY light flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY light stops flashing after the memory is viewed as shown above The MEMORY light is automatically cleared next time the panel is Armed MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS LIGHT MEMORY EVENT Zone
8. cameras Miniature hidden cameras Monitors even digital video recorders and remote telephone video systems SWITCHES A variety of switches are available for protecting doors and windows The line up includes surface and flush mount reed switches emergency buttons roller door reed switches and the unique Nessensor vibration sensor for highly effective perimeter protection NESS D16 V4 5 CONTROL PANEL USER MANUAL WIRELESS PRODUCTS RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door The Ness Radio Key provides the benefits of separate ON OFF and PANIC buttons in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel ates PF NESS RADIO KEY 3 BUTTON Fully waterproof ultra slim 3 button Radio Key for remote control of the control panel With separate buttons for ON Arm OFF Disarm and PANIC functions Includes long life lithium battery NESS RADIO KEY PENDANT 3 Fully waterproof pendant style i transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recomm
9. displayed O Press P CE a To exit Program Mode Deleting USER CODES At Step 3 enter MEMORY E instead of a new code O Press E a The existing code has now been erased EXAMPLES The pane must be in program mode Program light ON e To program User Code 1 to be 1234 P11E 1234 E 1234 E To program User Code 2 to be 5678 and as an ARM ONLY code P12E ARM E 5678 E 5678 E When an Arm Only code is displayed the ARM icon is displayed before the digits of the code e To delete User Code 2 P12E MEMORY E USER CODE PROGRAMMING RULES e All codes can be 3 4 5 or 6 digits long e Codes beginning with O zero can be programmed but they will not operate the panel This is an alternative method for disabling user codes however the MEMORY E function is recommended for deleting user codes e Codes are rejected if already used Some codes that are similar to existing codes may also be rejected e The Master Code User Code 1 cannot be an ARM ONLY code e The Master Code must always be programmed all other codes are optional For a list of programming option numbers see the Programming Options Table on page 19 NESS D16 V4 5 CONTROL PANEL USER MANUAL PROGRAMMING Programming TIMERS O Press P Master Code E dad Enters Program Mode The PROGRAM light will be on Press CP Option No E ad The existing time will be displayed Press NEW TIME E oa The new time will be di
10. lights 1 8 Zone alarm no lights Panel Disarmed ARMED maana ad Panel Armed or Area 1 Armed ARMZ insiet Area 2 Armed Mains power failure Low Battery EXCLUDE Panic alarm LINE san Telephone line fail RADIO EXCLUDE Radio Key Panic alarm Tamper alarm Siren cover panel etc RADIO BATTERY ZONE Radio Device battery low Device number is indicated by zone light s RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number is indicated by zone light s RADIO MONITOR ZONE Radio Supervision fail Device number is indicated by zone light s NESS D16 V4 5 CONTROL PANEL USER MANUAL RADIO KEY OPERATION NESS RADIO KEY 3 BUTTON The optional Ness Radio Key allows you to Arm Disarm and activate PANIC The Radio Key can also Arm Monitor Mode if this has been enabled by your installer ARMING Press the ON button The keypad will give 3 beeps The outside siren will give 1 chirp If enabled by your installer e The strobe light will flash briefly If Monitor Arming by Radio Key is enabled the chirp and flash will be delayed for 5 seconds DISARMING Press the OFF button The keypad will give 3 beeps The outside siren will give 3 chirps If enabled by your installer e The strobe light willtlash briefly ARMING MONIT
11. t Disarm the panel during this allowed time Disarming the system may be done by keypad or with the use of optional Radio Keys Monitor mode allows selected zones to be Armed while leaving others Disarmed if you wish to protect a number of zones while you are at home If you wish to split your alarm system into two areas with access limited to each area by code numbers then Area operation is used Radio Keys can also Arm and Disarm Areas The control panel housing and the covers over external sirens are protected by tamper switches to detect someone attempting to disable the security system Activation of these switches will cause an instant tamper alarm If a detector becomes faulty you can Exclude the associated zone so that it is totally ignored and cannot generate an alarm Including the zone will enable it to generate an alarm again The control panel is fitted with a rechargeable stand by battery to ensure your security system continues to operate if the mains power is interrupted This control panel automatically tests the battery every hour and whenever you Arm Disarm the panel Dynamic Battery test Whenever an alarm occurs it may be silenced with a User Code or by optional Radio Keys otherwise it will reset at the end of Alarm Reset Time All alarms are stored in memory and may be viewed at any time by entering Memory Mode NESS D16 V4 5 CONTROL PANEL USER MANUAL KEYPAD The Ness LCD keypad provide
12. INEAF De16 ALARM CONTROL PANEL AND DIALLER O MADERA AUSTRALIA VOS lv USER S MANUAL Ness D16 control panel User s manual A 15 00 INC GST Revision 4 5 MADE N AUSTRALIA AA iv N55 NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Quality Endorsed Company 1509001 LIC No QEC2074 Ness Security Products Pty Ltd NSW Head Office only WWW NESS COM AU HEAD OFFICE Ness Security Products Pty Ltd ABN 28 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au SYDNEY 02 8825 9222 MELBOURNE 03 9878 1022 BRISBANE 07 3343 7744 ADELAIDE Aquavia Controls 08 8277 7255 PERTH 08 9328 2511 NEW ZEALAND NFS NZ 64 9 573 0401 NESS D16 USER MANUAL Revision 4 5 June 2002 Document Part Number 890 247 For product 100 687 D16 Control Panel V4 5 2002 Ness Security Products Pty Ltd ABN 28 069 984 372 D16 user rev4 5 pmo180602 Specifications may change without notice CONTENTS F atUneS nih tatnihic mentee RR REN aaa 4 InthOdUCctiOn AA AA 5 Keypad maana aamiban RNGA GG ANAL AD ditdeertactease 6 Visual Indicators 0 00 eee rear 7 KEYPAD OPERATION 8 FAVA AA TA o RINS A AA a aa 9 DISARMING anakan sia AURA AIRA HAAN 10 Resetting Alarms ee 10 Monitor Mode rrenan 11 Keypad Panic
13. ITORING STATION MONITORED PREMISES TELEPHONE LINE The Primary and Secondary telephone numbers are normally only used for central station monitoring These numbers can only be programmed in Installer Program Mode The Follow Me Telephone Number replaces the Primary AND Secondary telephone numbers AUDIBLE MONITORING The D16 can also be programmed to send audible messages to any telephone or mobile phone When programmed for audible monitoring the D16 calls a pre programmed number or numbers and sounds a series of beeps over the phone These beeps can identify the zone or zones which caused the alarm and well as several other alarm types FOLLOW ME TELEPHONE NUMBER The Follow Me Telephone Number is the telephone number to which the D16 sends alarm reports when Audible Monitoring is enabled The Follow Me Telephone Number can be changed by the user in User program Mode If the Follow Me Telephone Number is programmed the Primary and Secondary telephone numbers are ignored even if programmed When Audible Monitoring is enabled See page 19 for information on programming the Follow Me Telephone Number AUDIBLE MONITORING SEQUENCE When triggered by an alarm the D16 will dial the programmed telephone number s and output the audible message for 45 seconds or until it is acknowledged ACKNOWLEDGING THE ALARM The person receiving the call can then acknowledge the alarm by pressing the key on their tele
14. J JJ 3 beeps 5 PRESS 1 to Arm the panel JJ 3 beeps 6 PRESS to finish and hang up NESS D16 V4 5 CONTROL PANEL USER MANUAL REMOTE OPERATION AUDIBLE FEEDBACK Jag 3 BEEPS e The User Code is valid e Successful Arming or Disarming e An Auxiliary output has been turned ON 2 1 LONG BEEP e D16 is already Armed e Invalid code Try again SUMMARY OF TELEPHONE COMMANDS Prepare to receive commands Arm Areas 4 Disarm Areas Turn Aux 1 Output ON or OFF Turn Aux 2 Output ON or OFF Finished hang up 2 ee 9 5 e J 1 SHORT BEEP e An Auxiliary output has been turned OFF NOTES Ss e If the D16 does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up e If an alarm occurs which requires the D16 to dial out while attempting remote control the D16 will treat the alarm as a priority give a constant tone as a warning and then hang up O When all remote control commands are finished press to force the D16 to hang up NESS D16 V4 5 CONTROL PANEL USER MANUAL NESS ACCESSORIES MABENA AUSTRALIA Le v EF RE J a i 100 021 100 226 100 210 100 048 Quantum Quantum Quantum Quantum 360 Plus Dual MOTION DETECTORS Ness manufactures a range of high quality and efficient motion detectors including passive infra red detectors dual techn
15. OR MODE If enabled by your installer Press the OFF button twice within 4 seconds or press the ON button twice within 5 seconds The keypad will give 9 beeps The outside siren will NOT chirp The strobe light will flash briefly PANIC Press and hold the PANIC button for at least 4 seconds The siren and strobe will activate If enabled by your installer The dialler will report a Panic alarm If enabled by your installer and if your system is monitored by a central station Press the OFF button to reset a Panic alarm The Ness Radio Key is optional and is not supplied with any Ness control panels as standard Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel NESS D16 V4 5 CONTROL PANEL USER MANUAL MONITORING CENTRAL STATION MONITORING The D16 control panel has an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and Disarm the system Central Station Monitoring is highly recommended and is the most effective method of monitoring your D16 alarm system For further information about 24 hour monitoring contact your installer or Ness Security Products CENTRAL STATION MONITORING MON
16. UND THE INTERNAL SIREN RESET OUTPUT THIS OPTION IS OFF BY DEFAULT NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION EMERGENCY FUNCTIONS KEYPAD FIRE ALARM Press 3 E Sounds the siren Fire Alarm siren sound e If Keypad Fire Alarm has been enabled by your installer Sends a Fire Alarm report by dialler e If your system is monitored by a central monitoring station e If Fire Alarm Report has been enabled by your installer KEYPAD MEDICAL ALARM Preso 2 E Sends a Medical Alarm report by dialler e If your system is monitored by a central monitoring station e If Medical Alarm Report as been enabled by your installer Medical Alarm does not sound sirens NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION EXCLUDING ZONES Press Cexe voe E ad Or User Code E O The Z EXCLUDE icon will turn on O Enter the zone number of the zone s to be Excluded Zone No E Zone No J E The zone light of each Excluded zone will turn on O Press E to exit Exclude mode O The YQ EXCLUDE icon will flash continuously If a detector becomes faulty and cannot be Sealed when arming the panel then its zone may be Excluded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously while the panel is Disarmed and also when Armed Zones can be excluded whilethe panel is either Disarmed or Armed See notes below NOTES Zone
17. ack and supports a 12V 7Ah battery to maintain system security under all power supply conditions Monitor Mode Home Mode Outputs are separately fused with Automatic Reset Fuses Day Mode and Door Chime feature Zone inputs can be split with two end of line resistors so that two detection devices ie reed switches can both be monitored to provide maximum security 30 Event Memory Supports 16 Radio Devices Radio PIRs Radio Reeds etc Supports 14 Radio Keys All inputs and outputs are heavily protected against lightning and high voltage supply transients An earth terminal is provided for extra protec tion 15 User Codes Arm only codes can be programmed Programmable Inputs to activate selectable Outputs Designed utilising the latest SMD Technology Simple to Program and Use NESS D16 V4 5 CONTROL PANEL USER MANUAL INTRODUCTION The Ness D16 micro computer based 16 zone control panel is the heart of your security system to which all your detection devices connect Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be connected to the D16 control system directly by cabling or with optional wireless Radio devices Detection devices called Passive Infra Red Detectors or P I R s for short can detect the movement of an intruder by sensing their body heat P I R s are used to cover various critical
18. attempting to enter Program Mode Try again using the Master Code NESS D16 V4 5 CONTROL PANEL USER MANUAL INSTALLATION RECORD Date purchased Date installed D 1 6 Installation Company DIALER SECURITY ALARM PANEL Telephone NESS D16 ALARM CONTROL PANEL Monitoring Company INSTALLATION RECORD Telephone E ZONE ASSIGNMENT ES a P26E ENTRY DELAY TIME 1 Seconds ra e 2 E gt gt 3 E0 5 3 a 5 O Ds P27E ENTRY DELAY TIME 2 Seconds dag So k k 5 c c gt 5 ere ee P28E EXIT DELAY TIME Seconds zeae EO bh 5az x EEZ EB 5ZFn k2z2z T2 E6525 8S 325936 2 P29E SIREN RESET TIME Minutes oo af pow GD O Ga a i o N o 19 o nya N 19 o N q st st st io N 19 19 N N N E O 2 a Aa a ya qoaaa aa ZONES DEVICE TYPE Cone DESCRIPTION Entrance bedroomt etc 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 AREA 1 AREA2 RADIO KEY CODE OPTION No CODE HOLDER CODE Y N User Code 1 t P11E Keypad Code only User Code 2 RA2E User Code 3 P13E User Code 4 P14E User Code 5 P15E User Code 6 P16E User Code 7 P17E User Code 8 P18E User Code 9 P19E User Code 10 P20E User Code 11 P21E User Code 12 P22E User Code 13 P23E User Code 14 P24E User Code 15 P25E 2002 Ness Security Products NESS D16 V4 5 CONTROL PANEL USER MANUAL
19. e 16 zones to be split into two partitions Area1 and Area2 The panel then effectively operates as two separate systems sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Area1 and Area2 are both Armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Area1 or Area Disarms OPERATION Arming and Disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the Armed state This means that Day 24hr and Monitor zones are independent of the area operations Note Area partitioning is in addition to Monitor Mode Any zone may be allocated to any area NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION ARMING O The Not Ready light should be off Press CARM E ee or User Code E L O The 5 amen icon will turn on e Leave the premises within the Exit Delay Time e 3 beeps will sound at the end of Exit Delay Time
20. em but it cannot Disarm See page 18 for User Codes programming If Entry Beeps are programmed on ALARMS DEFINITION Alarms may be caused by A zone has been triggered while Armed A Tamper has been triggered e A PANIC button has been triggered All of these may cause your sirens and strobe to operate Various visual indications relevant to the alarm will be retained in the memory If this occurs Disarming your control panel will reset the alarm The cause of the alarm can be identified by entering the Alarm Memory Mode as described on page 15 NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION MONITOR MODE O Press uonrror E ado or User Code E a The E monitor icon will turn on Only the zones which have been programmed by your installer as Monitor zones will be Armed Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home Your installer must program which zones will be active in Monitor mode The panel must be fully Disarmed before Arming in Monitor Mode If an alarm occurs while in Monitor mode entering User Code E will silence the alarm This wilPalso Disarm the panel so remember to enter monitor again if needed Using the optional Radio Keys you can enter Monitor Mode by pressing the OFF button twice within 4 seconds or by pressing the ON button twice within 5 sec
21. ended when used for medical alarm purposes Includes long life lithium battery NESS RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery NESS RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the Ness D16 D16 amp D24 control panels Also operates Monitor mode and Panic when used with the Ness D16 D24 panels The Ness radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires NESS RADIO PIR Ness Radio PIR Passive Infrared and gt Ness R12 Radio PIR for wireless motion KO E detection O BO Can be used in combination with Ness Ness R12 Radio PR hardwired detectors in areas where it is not possible to install wires Includes long life lithium battery The Ness Radio PIR Pet Aware model detects humans but is immune to household pets Allows you to protect your home with your pets inside 1 yy rue Ness Radio PIR amp Ness Ya Pet Aware Radio PIR PET AWARE NESS RADIO SMOKE DETECTOR Radio Smoke Detector using lonisation smoke detection technology With on board sounder A single battery powers the smoke detector and the transmitter Includes 9V lithium battery N NESS D16 V4 5 CONTROL PANEL USER MANUAL TROUBLESHOOTING SYMPTOM Zone light on or long beeps when Arming
22. er codes that are programmed to be Arm Only codes can arm the panel from Monitor mode or from the disarmed state NESS D16 V4 5 CONTROL PANEL USER MANUAL
23. ises You need to know the telephone number of the line that the D16 is connected to SEQUENCE OF OPERATION 1 Phone the D16 telephone number and listen for the required number of rings ring ring ring ring and then hang up Wait 10 seconds and then call the number again within 50 seconds The D16 will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The D16 is now ready to receive telephone commands Press the 0 button on the telephone This tells the D16 that telephone commands will follow It will respond with either 3 beeps if all OK One long beep means try again Now enter lt a valid User Code that is normally used for Arming or Disarming the D16 followed by the button The D16 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again Enter the required command See Summary Of Telephone Commands Press to finish This tells the D16 to hang up Also hang up your telephone EXAMPLE ARMING THE D16 BY TELEPHONE 1 Dial the D16 telephone number Listen for one double ring then hang up 2 Wait 10 seconds then dial the D16 telephone number again The D16 will answer immediately and gives a 2 second beep followed by low tone 3 PRESS 0 To prepare the D16 Jaa 3 beeps 4 PRESS User Code to authorise the next command
24. nter the premises through a delay zone Press User Code E doa O The 5 armen icon will turn off When you enter the protected premises through a delay zone the keypad responds with regular beeps as a reminder to Disarm You then have your programmed entry delay time to Disarm the panel by entering one of your user codes If the panel is not Disarmed by the end of the entry delay time an alarm will occur By using the optional radio keys you may Disarm your system from within your premises or from outside your entrance door There is also the option to Chirp the outside siren three times and to flash the strobe light for two RESETTING ALARMS Your panel can be reset and the alarm silenced by the same key sequence as Disarming the panel If you arrive at your premises and find the strobe light flashing if installed reset the panel as above To check the cause of the alarm you can view the alarms in memory by entering Memory Mode In the event of an alarm the strobe light continues to flash until the panel is reset by the keypad or radio key otherwise it will time out after 72 hours seconds as an indication that you have Disarmed your system If you make a mistake in entering your code then you m st press enter and start again Five incorrect entries will cause an alarm Note that user codes can optionally be programmed to be Arm Only codes By definition an Arm Only code can Arm the syst
25. ode LED Keypad only kap ARM2 Disarmed Armed AREA 2 MONITOR Disarmed Monitor Mode q MAINS ormal Mains Power is off E BATTERY ormal The panel s backup battery is low ALARM M MEMORY ormal Memory Mode selected New alarms in memory EXCLUDE ormal Zones are excluded T TAMPER ormal Tamper alarm o RADIO ormal Receiving radio signal Indicates that a Radio Key or other radio device has a low battery a LINE ormal Dialler is on line Phone line fault or failure to communicate PROGRAM ormal User Program Mode Installer Program Mode Not Ready O Ready to Arm Not ready to Arm MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS LIGHT MEMORY EVENT Zone lights 1 16 s Zone alarm NO JightS AA Panel Disarmed ARMED eee Panel Armed or Area 1 Armed ARMA Area 2 Armed MAINS maana Mains power failure BATTERY ccsescsceeseceesesees Low Battery TAMPER Tamper alarm Siren cover panel etc EXCLUDE siioni Panic alarm LINE seara ng Telephone line fail Radio Key Panic alarm RADIO BATTERY ZONE Radio Device battery low Device number is indicated by zone light s RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number is indicated by z
26. ology microwave and infra red devices as well as ceiling mounted 360 detectors All Ness detectors are designed using the most modern technology and techniques that ensure superior reliability and performance QUANTUM 15m passive infra red detector with selectable pulse count suitable for domestic and commercial installations PetAware model available QUANTUM PLUS 15m passive infra red detector with selectable pulse count temperature compensation and downward looking creep zones x nG QUANTUM DUAL 15m combination microwave and passive infra red detector This combination ofdetection technologies virtually eliminates the possibility of unwanted alarms but faithfully detects humans PetAware model available Ay QUANTUM 360 Ceiling mounted 360 passive infra red detector with selectable pulse count and sensitivity Provides 8 metre coverage mounted at standard 2 4 metre ceiling height PET AWARE DETECTORS The Ness Quantum Pet Aware PIR Pet Aware Radio PIR and the Pet Aware DUAL are able to discriminate between household pets and unwanted human intruders allowing you to secure your home with your pets indoors PET AWARE ie CSS BR S tt SIRENS The range of warning devices includes horn speakers polytough siren covers internal screamers and satellite sirens with their own battery backup KI CCTV The Ness range of Closed Circuit TV equipment includes Dome cameras B W or Colour
27. onds Your installer must enable Radio Key Monitor Arming for this to work NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION EMERGENCY FUNCTIONS KEYPAD PANIC Press D Both keys together Or T D User Code E or E If Keypad Panic Shortcut has been enabled by your installer The keypad PANIC function may have been programmed to be either AUDIBLE activates siren or buzzers or SILENT If your system is monitored by a Central Station sends a PANIC report by dialler If PANIC reports have been enabled by your installer KEYPAD DURESS PANIC cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate PANIC button To activate the panic alarm simply press that button Press C 5 Both keys together Or T User Code E or ME If Keypad Panic Shortcut has been enabled by your installer The DURESS alarm can be used to send a silent alarm to the Central Station that you are being forced to Disarm the panel against your will That is you are disarming under duress To Disarm and send a DURESS alarm prefix your User Code with one of the digits 5 6 8 or 9 when Disarming DURESS IS NORMALLY NOT ENABLED TO ENABLE THE DURESS FUNCTION CONSULT YOUR INSTALLER DURESS ALARMS CAN ONLY USED BY SYSTEMS WHICH ARE MONITORED BY A CENTRAL STATION THE DURESS ALARM CAN BE PROGRAMMED TO SO
28. one light s RADIO MONITOR ZONE Radio Supervision fail Device number is indicated by zone light s NESS D16 V4 5 CONTROL PANEL USER MANUAL OPERATION This section describes the operation of a typical control panel installation Keep in mind that your installation may vary depending on the selected options and equipment The operating instructions which follow will endeavour to cover the most common options Consult your installation company if you require further information All control panel operations are controlled by the D16 keypad except if an optional key switch or radio control equipment is installed OPERATING RULES Generally the panel will be Disarmed Armed or Monitor modes provide different levels of security for your premises when you are home or away Three other temporary modes Program Memory and Exclude allow you to perform various operations The panel will automatically exit from these temporary modes if you do not press any buttons on the keypad in a 4 minute period If you make a mistake while entering any codes press the enter button and start again When you are required to enter your access code you are given five opportunities to enter it correctly After the fifth invalid attempt the alarm is activated requiring the correct code to silence the alarm This prevents anyone trying to guess your code by entering random numbers AREA OPERATION Area Partitioning allows th
29. phone Press the key for at least 2 seconds during pauses in the audible message Ifthe alarm is not acknowledged the keypad s LINE light will flash continuously until the panel is next Armed AUDIBLE MONITORING MONITORED PREMISES TELEPHONE LINE NESS D16 V4 5 CONTROL PANEL USER MANUAL PROGRAMMING Various system options can be programmed by the user These options can only be accessed from Program Mode User Codes may need to be re programmed if a person has forgotten their code to give a new user access to the system or to give someone temporary access User Codes 2 15 can be set as Arm Only Codes These codes can Arm but cannot Disarm the panel Useful for assigning to cleaners tradesmen etc You may need to change the Entry and Exit timers if you find the delays are too long or short If Audible Monitoring is programmed by your installer the Follow Me Telephone Number is the telephone number the dialler will call in the event of an alarm If your Ness D16 panel is monitored by a Central Station the Follow Me number is ignored For all other programming changes talk to your installer The panel will automatically exit Program Mode is no buttons are pressed within a 4 minute period To enter PROGRAM MODE Master Code P Master Code E To exit PROGRAM MODE EATER 15883 P CE
30. s important visual and audible indication of the system status and is the main interface for controlling the many powerful features of the D16 system Information is displayed on a large LCD icon display which is backlit for easy night viewing DISPLAY TEST To display all the keypad icons press and hold the E button for at least 2 seconds All the icons will be on whilst the E button is held down Display Test can be activated at any time either in operating mode or any program mode BACKLIT LCD ICON DISPLAY 2 0 r 1 91 dE Not Ready light DY ARMED ARM2 ALARM TAMPER RADIO MEMORY D E MONITOR BATTERY MAINS EXCLUDE PROGRAM LINE KEYPAD BEEPER Not Ready o PANIC BUTTONS ARM BUTTON MONITOR BUTTON EXCLUDE BUTTON EACH KEY PRESS 1 beep VALID ENTRY ddd 3 beeps ERROR BEEP JJ Li long beep MAINS POWER IS OFF or BATTERY IS LOW MEMORY BUTTON o TLOTL 10 beeps PROGRAM BUTTON ENTER BUTTON NESS D16 V4 5 CONTROL PANEL USER MANUAL VISUAL INDICATORS KEYPAD ICON DISPLAY ZONES 1 16 Zone is sealed KEYPAD ICON STATUS O ON Zone is unsealed oi O FLASHING Zone alarm vV READY Zone is unsealed or Power fault or System is Armed or phone line fault Ready to Arm Gi ARMED Disarmed Armed AREA 1 Monitor M
31. splayed O Press P CE s To exit Program Mode EXAMPLES The pane must be in program mode Program light ON e To program the Entry Delay Time to be 15 seconds P26E 15 E e To program the Exit Delay Time to be 40 seconds P28E 40 E For a list of programming option numbers see the Programming Options Table on page 19 Programming the FOLLOW ME TELEPHONE NUMBER O Press XP Master Code E ee Enters Program Mode The PROGRAM light will be on Press P 0 0 E is The existing telephone number if any will be displayed ddd The new telephone number will be displayed O Press NEW TELEPHONE NUMBER E Press P To exit Program Mode EXAMPLES The panel must be in program mode Program light ON To program the Follow Me Telephone Number to be 9123 1234 POOE 91231234 E To delete the Follow Me Telephone Number POOE MEMORY E NESS D16 V4 5 CONTROL PANEL USER MANUAL REMOTE OPERATION OPERATING THE D16 BY TELEPHONE The D16 will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2 To ensure security of operation a user can only carry out remote operations after entering a valid user code WHAT S NEEDED A telephone with DTMF tones e A Valid User code programmed in the D16 e The D16 to be connected via Mode 3 socket to a working telephone line at the installed prem

Download Pdf Manuals

image

Related Search

Related Contents

V7 Replacement Battery for selected Dell Notebooks  folleto manejo de animales menores cuyes  Datasheet - Mouser Electronics  manual cañ2001    

Copyright © All rights reserved.
Failed to retrieve file