Rocking Platform RT 26, TT 30 user manual
Contents
1. 50 60 Hz 0 3 A Fuse 2 x 0 5 A 230 V 2x1A 115V Operating Conditions 4 C to 70 C up to 85 relative humidity non condensing Suitable for use in cold room and incubators Included accessories One flat rubber mat One flat rubber mat and one dimpled mat 3 Legal Notes 3 1 Copyright All rights reserved It is not allowed to copy and publish the manual or parts of it in any form as copies micro film or other methods without a written authorisation from Biometra Biometra is pointing out that applied company and brand names are usually protected trade marks 3 2 Liability Biometra is not liable for damages and injuries caused by use not considering these operation instructions in parts or completely 3 3 Meaning of the instructions Biometra recommends that you first read these instructions carefully Then assemble and disassemble the apparatus to become familiar with the system After these preliminary steps you should be ready to transfer a sample This operation instruction is part of the product and should be kept over the full life time of the instrument It should also be forwarded to subsequent owners and users Make sure that additions and updates are inserted into the operation instructions Biometra gt DI RT 26 and TT 30 Manual Vers 01_13 OD analytikjena 4 Safety instructions Before you connect the power cable to the mains supply check that P PPR DbDbD gt D gt D gt D the voltag
2. Zu diesem Zweck kontaktieren Sie bitte unsere Service Abteilung Au erhalb Deutschlands wenden Sie sich bitte an den f r Sie zust ndigen H ndler Dieses Symbol gilt nur in Staaten des EWR EWR Europ ischer Wirtschaftsraum umfasst die EU Mitgliedsstaaten sowie Norwegen Island und Liechtenstein This symbol the crossed out wheelie bin means that this product should be brought to the return or separate systems available to end users according to yours country regulations when this product has reached the end of its lifetime For details please contact your local distributor This symbol applies only to the countries within the EEAY EEA European Economics Area comprising all EU members plus Norway Iceland and Liechtenstein Cet symbole conteneur a d chets barr d une croix signifie que le produit en fin de vie doit tre retourn a un des syst mes de collecte mis a la disposition des utilisateurs finaux en consequence des regulations par la loi de votre pays Pour des information additionel nous Vous demandons de contacter votre distributeur Cet symbole s applique uniquement aux pays de EEE EEE Espace conomique europ en qui Biometra gt DI RT 26 and TT 30 Manual Vers 01_13 P analytikjena 14 Warranty This laboratory instrument is produced with the highest practical standards of materials workmanship and design The design and manufacture of parts have been conceived with one purpo
3. Biometra PRODUCT LINE Rocking Platform RT 26 Tumbling Table TT 30 Instruction Manual Version 01 13 Order No 34 9990 109 23 Model Order No RT 26 230 V 846 042 200 RT 26 115 V 846 042 290 TT 30 230 V 846 042 300 TT 30 115 V 846 042 390 analytikjena Please read these instructions carefully before using this apparatus Biometra GmbH Service Department Rudolf Wissell Str 30 Rudolf Wissell Str 14 16 D 37079 Gottingen D 37079 Gottingen Tel 49 551 50 68 6 0 Tel 49551 50 68 6 10 or 12 Fax 49 551 50 68 6 66 Fax 49 551 50 68 6 11 E mail Info biometra com E mail Service biometra com Internet http www biometra com 2 Contents 1 Intended use and SPECIFICATIONS 000 0 eccescccccesssscecceesssseeeceeessseeceeessseesceeeesseececeessseeeceeessseeceeeesseeeceeeaaes 4 ee ee E 5 SB Be et 5 3 1 ele VIVE EE 5 3 2 Rtl 5 3 3 Meaning Or tat Diere EE 5 d ode INSEUCHORS anni een een 6 5 SEO UP OPETANON E 7 5 1 Scope of Delivery ueeeeeesssessssssssenssssnnnnnnssnnnnnnnnnnnnnnnnnnsnnnnnnnnnnnnnnnonnnsnnnnnnsnnsnsnnnsnsssnnnssssssnnnnsssssnnennnen T 5 2 UPI eA IMIG DEE 7 6 Installation in the Laboratory eee cccsseccesssseeesesseeceesseecesseescseaeecessasecesesaesesesaeecesesseecseaaeeeeeaeeeeseaes 8 6 1 Selecting the correct LOCATION eessen peie aaa EENS ei PE EERE EAEEREN N EAEE EARS 8 6 2 Attaching the power cord ssesesssneessnsesssenesseeessssressseesssoressosesssnressoressseresso
4. ETRA 10 Transportation and storage To prevent damage it is best to store and transport the shaker and its components in their original packaging or other suitable container Close the packaging with adhesive tape Store the mixer shaker in a dry place AN CAUTION Protect the instrument from impact and vibration during transport Biometra gt DI RT 26 and TT 30 Manual Vers 01_13 e analytikjena 11 Service Should you have any problems with this unit please contact our service department or your local Biometra dealer Biometra GmbH Service Department Rudolf Wissell StraBe 14 16 D 37079 G ttingen Phone 49 551 50 686 10 or 12 Fax 49 551 50 686 11 e mail Service biometra com A If you would like to send the unit back to us please read the following return instructions 11 1 Instructions for return shipment e Return only defective devices For technical problems which are not definitively recognisable as device faults please contact the Technical Service Department at Biometra e Please contact our service department for providing a return authorization number RAN This number has to be applied clearly visible to the outer box Returns without the RAN will not be accepted e Important Carefully clean all parts of the instrument from residues and of biologically A dangerous chemical or radioactive contaminants If an instrument is contaminated Biometra will be forced to refuse to accept
5. bber pad is easy to replace Vessels must be secured to the shaking platform in central position and evenly spaced Shaking frequency is adjustable from 10 to 120 rocks min The tilt angle is 7 Tumbling Table TT 30 The Tumbling Table TT 30 is used for the shaking of vessels particularly flasks bottles and dye pans with a gentle asymmetrical motion Vessels are placed on the rubber pad that is supplied with the shaker The rubber pad is easy to replace Tumbling frequency is adjustable from 3 to 60 cycles min The angle of inclination is 7 Do not attempt to operate this device if physical damage is present Read the complete instruction manual thoroughly and make sure that every user of the shaker has also read the instructions thoroughly before taking the equipment into operation lf after reading the instruction manual you still have any questions concerning the installation operation or maintenance of the shaker please contact BIOMETRA or your local BIOMETRA distributor Biometra NI analytikjena 5 2 Specifications Dimensions 289 x 320 x 160 330 x 352 x 210 W x D x H mm Platform dimensions 260 x 198 300 x 300 W x D mm Hot ko Speed 10 120 tilts min 3 60 rom Timer 10 120 min in 10 min steps HOLD function Tilt angle 7 Electrical requirements 230 V model 230 V 10 50 60 Hz 0 1 A 230 V 10 50 60 Hz 0 15 A 115 V model 115 V 10 50 60 Hz 0 2A 115 V 10
6. e and frequency of the shaker conforms with the line voltage the voltage rating of your shaker is printed on the type label the power switch is set to 0 and the control knobs have all been turned counterclockwise up to the stop This will prevent spills due to sudden overly vigorous shaking The shaker is not protected for use in explosive atmospheres Be careful when using it close to flammable and explosive substances The laboratory table must be strong and have a flat and non slip surface Before you start up the shaker make sure that the vessel process medium is secure and cannot slip Take precautions to prevent attachments or vessels colliding with other objects on the laboratory table during the shaking operation To guard against splashing and spills close the shaking vessels carefully When you work with open vessels select the shaking frequency accordingly To prevent unintentional violent shaking it is always advisable to start with a low shaking frequency and to increase it gradually in small steps until you reach the shaking effect you require Always place single vessels at the centre of the platform When working with several vessels always arrange them equally on the platform Take care for the maximum load Observe the pertinent safety regulations when working with hazardous media Make allowance for the tilt angle when using tall vessels Biometra HIT RT 26 and TT 30 Manual Vers 01_13 ana
7. h Date Hazardous materials used with this equipment Method of cleaning decontamination The equipment has been cleaned and decontaminated NAME POSITION HEAD OF DIV DEP INSTITUTE COMPANY SIGNED DATE PLEASE RETURN THIS FORM TO BIOMETRA GMBH OR YOUR LOCAL BIOMETRA DISTRIBUTOR TOGETHER WITH THE EQUIPMENT PLEASE ATTACH THIS CERTIFICATE OUTSIDE THE PACKAGING INSTRUMENTS WITHOUT THIS CERTIFICATE ATTACHED WILL BE RETURNED TO SENDER Biometra gt DI RT 26 and TT 30 Manual Vers 01_13 ia analytikjena General Information for Decontamination Please contact your responsible health amp safety officer for details Use of radioactive substances Please contact your responsible person for details Use of genetically change organism or parts of those Please contact your responsible person for details Biometra DU RT 26 and TT 30 Manual Vers 01_13 analytikjena re 13 Note for Disposal of Electric Electronic Waste Due to the application in a laboratory the darkhood must be decontaminated before return as electronic waste fur die Entsorgung von Hinweis Elektroaltgeraten for disposal of electric Note electronical waste du traitement des dechets des Renseignement appareils electrique electronique Das Symbol der durchgestrichenen Abfalltonne bedeutet f r unsere Kunden in Deutschland da dieses Produkt von der Firma Biometra kostenlos zur Entsorgung zur ckgenommen wird
8. ic solvents e Do not insert any objects into the rocker such as screw driver or metal rods e Never operate the shaker without platform securely attached e Hazardous samples should be shaken only in appropriate containment vessels RT 26 and TT 30 Manual Vers 01_13 analytikjena m 8 Troubleshooting guide Be sure to disconnect the rocker from the main power source immediately in case of any signs of malfunction and contact Biometra GmbH Service Department Problem Explanation Solution POWER switch doesn t light up Check the power connection Check fuses Rocker does not START Check the power connection Check fuses 9 Routine maintenance cleaning e No routine maintenance or lubrication is required e It is recommended that the rocker is kept clean to insure long trouble free operation The outside housing can be cleaned with a soft damp cloth when needed mild suds Do not use any aggressive or abrasive cleaners acetone nitro polish chlorine bleach detergents based on chlorine scouring powder ammonium cleaning wool or agents with metallic constituents etc This may permanently damage the rocker finish AN Before cleaning the rocker always unplug the power cord from the wall socket lf your BIOMETRA product ever needs to be repaired you should enlist the services of a specialist who has been authorized by BIOMETRA to carry out such work Contact your local BIOMETRA dealer or get in direct touch with BIOM
9. lytikjena e D Setting Up Operation 5 1 Scope of Delivery The following parts are supplied Compare the contents of the shipment before discarding the packing materials We recommend keeping the original packing for future transport or storage purposes RT 26 TT 30 846 042 200 846 042 290 846 042 300 846 042 390 Flat rubber mat Dimpledrubbermat Ill Senseful optional accessories Blot Boxes with lids for safe mixinig of liquids The boxes are made of polystyrene and completely transparent 846 042 00 1 Blot Box with lid 9 1 cm x 6 6 cm 3 to 5 ml capacity for mini gels 10 pieces package 846 042 002 Blot Box with lid 11 7 cm x 8 9 cm 6 to 10 ml capacity for slightly larger mini gels 10 pieces package 5 2 Unpacking Before starting the installation carefully examine the rocker for possible damage or missing parts e Open the box and carefully remove the padding Check that the rocker has not been visibly damaged during transportation Keep the packing material until you are sure that the rocker works properly e Carefully lift the device out of the box e Be sure that the following information is included on the serial label located on the back of the unit Serial Number Product number Electrical rating Biometra gt DI RT 26 and TT 30 Manual Vers 01_13 s analytikjena e Check that the power cord has a pin configuration that fits into a wall socket according to the local standard Sho
10. r EG Richtlinie fiir die elektromagnetische Vertraglichkeit 2004 108 EG following the EC directive about the electromagnetic compatibility 2004 108 EC Hiermit erklaren wir dass folgende Wipptische Herewith we declare that the following Rocking Platforms Typen types TT 30 230 V TT 30 115 V Best Nr Order No 846 042 300 846 042 390 Typen types RT 26 230 V RT 26 115 V Best Nr Order No 846 042 200 846 042 290 den grundlegenden Anforderungen der corresponds to the basic requirements of EG Niederspannungsrichtlinie 2006 95 EG und der EC low voltage directive 2006 95 EC and the EG Richtlinie Gber die elektromagnetische Vertraglichkeit 2004 108 EG entsprechen EC directive about the electromagnetic compatibility 2004 108 EC Dr Lutz Heine Quality Manager Certificate number FS 68563 RT 26 and TT 30 Manual Vers 01 13 b analytikjena 1 Intended use and specifications The Rocking Platform RT 26 and the Tumbling Table TT 30 have been developed specially for the shaking and mixing of substances for scientific purposes in laboratories They are ideal for applications requiring mixing or agitation of solutions e g staining and destaining Rocking Table RT 26 gege The Rocking Table RT 26 is used for the shaking of vessels Wir particularly flasks bottles and dye pans with a gentle rocking motion bego Vessels are placed on the rubber pad that is supplied with the shaker u ze The ru
11. r speed 3 TIME potentiometer set time of the rocker to the desired value or on HOLD for continuous running HOLD yellow light illuminates when the rocker is set on HOLD for continuous running 5 START STOP button START or STOP rocking The device automatically stops after the set time passes Note Pressing the START stop button during operation will reset the timer 6 RUN green light illuminates when the rocker is running RT 26 and TT 30 Manual Vers 01 13 P analytikjena 7 2 Tumbling Table TT 30 so 60 70 s0 17 92 RN oN I 100 EN START 10 HOLD TIME MIN POWER switch to turn the rocker ON power switch illuminates or OFF SPEED potentiometer to set the rocker speed 3 TIME potentiometer set time of the rocker to the desired value or on HOLD for continuous running HOLD yellow light illuminates when the rocker is set on HOLD for continuous running 5 START STOP button START or STOP rocking The device automatically stops after the set time passes Note Pressing the START stop button during operation will reset the timer 6 RUN green light illuminates when the rocker is running 7 3 General instructions A Do not use the rocker near water sources Be sure that water doesn t get on the device especially during the cleaning procedures A Do not rock flammable or explosive samples e Do not expose the shaker to aggressive vapors e g organ
12. se to produce units which will give satisfactory service Biometra GmbH guarantees this unit to be free from defects in materials or workmanship under normal use or service for 24 month from date of shipment If during this time this unit proves defective in materials or workmanship Biometra GmbH will repair or replace it free of charge if returned to us prepaid This guarantee does not cover damage in transit damage caused by carelessness misuse or neglect or unsatisfactory performance as a result of conditions beyond our control or consequential losses as a result of failure of our product Biometra HIT RT 26 and TT 30 Manual Vers 01_13
13. srssseressoressseressoressseresserens 8 7 e Ee Ee TE 9 7 1 FOCK BG TODE RT EE 9 7 2 Tumblina Tapie TI BO EE 10 7 3 General instructions u 10 8 Troubleshooting guide 22220000220snnessnnnnennnnnnnnnnnnnnnnnnnnnnnnnunnnnnnnnnnnnsnnnnnsnunnnsnsennnnsssnnnnsssennnssennennnn 11 9 Routine maintenance cleaning sonsseonnessneesoneessnoessseesseeessssressosesssresssoresssnressoresssrrssseresserresseresseeens 11 10 Transportation and storage en een tee cedataters 11 11 Se 12 11 1 Instructions for return sbupment cece ccccescccessseceeesseecceesseeeeesseeceesseeeceesseeeeesseeeseeseeeeessseeeeesaeees 12 12 Equipment Decontamination Certificate ce ceeccccscsssscssnscessessssessseesessesesseseaseseasessasessaseseaseseas 13 13 Note for Disposal of Electric Electronic Waste cece cccccccsssccceesssseeccceessseeceeesssseeceeessseeeeeeesaeeees 15 14 NAW AMMEN E 16 analytikjena This document describes the state at the time of publishing It needs not necessarily agree with future versions Subject to change Biometra DU RT 26 and TT 30 Manual Vers 01_13 analytikjena EU Konformit tserkl rung EC Declaration of Conformity G ttingen September 2013 im Sinne der EG Richtlinie ber elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 2006 95 EG following the EC directive about electrical equipment for use within certain limits of voltage 2006 95 EC und and im Sinne de
14. the device The sender of the repair order will be held liable for possible damages and losses resulting from insufficient decontamination of the device e Please prepare written confirmation use the Equipment Decontamination Declaration following on the next page that the device is free of biologically dangerous chemical or radioactive contaminants This confirmation must be attached to the outside of the packaging e Use the original packing or a similarly robust packing when returning the device If not available contact Biometra or your local distributor e Label the outside of the box with CAUTION SENSITIVE INSTRUMENT and the RAN number sticker Attach the Decontamination Declaration e Please enclose a note which contains the following a Senders name and address b Name of a contact person for further inquiries with telephone number c Precise description of the fault which also reveals during which procedures the fault occurred if possible Biometra RT 26 and TT 30 Manual Vers 01_13 analytikjena m 12 Equipment Decontamination Certificate To enable us to comply with German law i e 71 StrlSchV 817 GefStoffV and 19 ChemG and to avoid exposure to hazardous materials during handling or repair please complete this form prior to the equipment leaving your laboratory COMPANY INSTITUTE ADDRESS PHONE NO FAX NO E MAIL EQUIPMENT Model Serial No If on loan evaluation Start Date Finis
15. uld any kind of damage have occurred during transportation contact the carrier immediately Do not attempt to operate this device if physical damage is present Please keep the original packing material for return shipment in case of service issues 6 Installation in the Laboratory 6 1 Selecting the correct location When locating the rocker please consider following e Put the rocker on horizontal leveled and stable surface e Leave enough space around the rocker for normal air circulation min 10 cm e Leave enough space around the rocker for easy access and maintenance e Avoid locations subject to shocks and vibrations e Avoid locations subject to frequent power fluctuations or power losses It may affect rocker performance Note There has to be an easy access to the rocker control panel and main plug in case of emergency 6 2 Attaching the power cord First connect the main power cord to the rocker then connect the plug end of the cord toa grounded wall socket Avoid lines on which powerful electric motors refrigerators and similar devices are connected A Be careful when you plug the cord to a grounded wall socket Do not touch plug with wet hand Do not pull the plug by the cord Biometra RT 26 and TT 30 Manual Vers 01_13 analytikjena 9 7 Instructions for use 7 1 Rocking Table RT 26 1 POWER switch to turn the rocker ON power switch illuminates or OFF 2 SPEED potentiometer to set the rocke
Download Pdf Manuals
Related Search
Related Contents
Product Training EFOY-Fuel Cells Corsa, v.5 Honda H1000 Series User's Manual Untitled Guia do usuário do ToxiRAE 3 Samsung 29" Premium Zakrivljeni Monitor S29E790C Priručnik za korisnike Wireless Network Adapter User`s Manual la subjectivité chez roger brunet et alain huetz de lemps fiche technique Copyright © All rights reserved.