Home
Trimble M3 DR Series Total Station User Guide
Contents
1. 20 Detaching and re attaching the battery pack 24 Detaching the battery pack 24 Inserting the battery pack 24 Setting up the tripod 25 Centering 25 Centering using the laser plummet 25 Centering using a plumb bob 26 Leveling 26 Sighting 27 Setting the measurement mode and preparing the target 28 Measurement with a prism 28 Measurement in reflectorless mode 29 Setting up the prism reflector
2. 48 Angle measurement 48 Tilt sensor 48 Tangent screw 49 Tribrach 49 Level 49 Optical plummet Trimble M3 DR 1 only 49 Laser plummet Trimble M3 DR 2 3 5 49 Display and keypad 49 Connections in the instrument 50 Battery pack 50 Environmental performance 50 Dimensions 50 Weight
3. 30 Adjusting the height of the tribrach adapter 31 Changing the direction of the prism 31 Setting the position of the target plate 31 3 Getting Started 33 Turning the instrument ON and OFF 34 Turning on the instrument 34 Turning off the instrument 34 Basic operation 35 Turning on and off the Backlight 35 Other functions 35 Contents 12 Trimble M3 DR Series Total Station User Guide Auto power off setting 37 Date Time settings 38 4 Checking and Adjustment
4. 3 Cautions 4 Rechargeable Lithium ion Li ion batteries 5 Laser safety 6 Trimble M3 DR 1 and 2 total stations 7 Trimble M3 DR 3 and 5 total stations 8 Instrument labels 8 1 Introduction 13 Parts of the instrument 14 Maintenance 16 2 Preparation 19 Unpacking and packing the instrument 20 Unpacking 20 Packing 20 Charging the battery pack
5. 39 Adjusting the electronic level 40 Checking and adjusting the circular level 40 Checking and adjusting the optical laser plummet 40 Zero point errors of vertical scale and horizontal angle corrections 41 Checking 41 Adjusting 41 Checking the instrument constant 42 Checking the laser pointer 43 5 Specifications 45 Main body 46 Telescope 46 Measurement range 46 Distance precision 47 Measurement intervals
6. Tripod Target plate for single prism Tiltable single prism holder Prism C Target pole Triple prism holder Height adjust ment adapter is not used W30 W30b adapter 15 Trimble M3 DR Series Total Station User Guide 31 Preparation 2 Adjusting the height of the tribrach adapter The tribrach adapter has a height adjustment adapter To use the prism reflector with a Trimble M3 DR instrument remove the height adjustment adapter as shown in the following figure The height adjustment adapter is used with other Nikon Total Stations Changing the direction of the prism The prism mounted on the tribrach adapter can be rotated to face in any direction To change the direction of the prism 1 Release the rotation clamp To do this turn the clamp lever counterclockwise 2 Turn the upper plate of the tribrach adapter until the prism is facing in the required direction 3 Fasten the rotation clamp To do this turn the clamp lever clockwise Setting the position of the target plate If using a single prism make sure that the target plate is aligned with the tribrach adapter and the prism To set the position of the target plate 1 Use the two set screws supplied to attach the target plate to the single prism holder 2 Move the target plate within the screw holes until the apex of the wedge pattern is aligned with the vertical axis of the prism and the tribrach adapter Height adjustment adapt
7. and the following notes C WARNING Do not damage the rechargeable Lithium ion battery A damaged battery can cause an explosion or fire and can result in personal injury and or property damage To prevent injury or damage Do not use or charge the battery if it appears to be damaged Signs of damage include but are not limited to discoloration warping and leaking battery fluid Do not expose the battery to fire high temperature or direct sunlight Do not immerse the battery in water Do not use or store the battery inside a vehicle during hot weather Do not drop or puncture the battery Do not open the battery or short circuit its contacts C WARNING Avoid contact with the rechargeable Lithium ion battery if it appears to be leaking Battery fluid is corrosive and contact with it can result in personal injury and or property damage To prevent injury or damage If the battery leaks avoid contact with the battery fluid If battery fluid gets into your eyes immediately rinse your eyes with clean water and seek medical attention Do not rub your eyes If battery fluid gets onto your skin or clothing immediately use clean water to wash off the battery fluid Trimble M3 DR Series Total Station User Guide 21 Preparation 2 C WARNING Charge and use the rechargeable Lithium ion battery only in strict accordance with the instructions Charging or using the battery in unauthorized equ
8. adapter Telescopic prism pole Coaxial target plate for single prism Tiltable single prism holder Prism adapter Tripod for telescopic prism pole Standard round single prism C Target pole Triple prism holder Tribrach adapter 15 Nikon tripod Tribrach W30 W30b Height adjustment adapter is not used NORTH AMERICA Trimble Engineering amp Construction Group 5475 Kellenburger Road Dayton Ohio 45424 1099 USA 800 538 7800 Toll Free 1 937 245 5154 Phone 1 937 233 9441 Fax EUROPE Trimble Germany GmbH Am Prime Parc 11 65479 Raunheim GERMANY 49 6142 2100 0 Phone 49 6142 2100 550 Fax ASIA PACIFIC Trimble Navigation Singapore Pty Limited 80 Marine Parade Road 22 06 Parkway Parade Singapore 449269 SINGAPORE 65 6348 2212 Phone 65 6348 2232 Fax www trimble com
9. be longer in the following cases the angle of the laser against the target is small the surface of the target is wet In direct sunlight the measurable distance may be shorter In this case try to throw a shadow on the target Targets with completely flat surfaces such as mirrors cannot be measured unless the beam and the target are perpendicular to each other Note Make sure there are no obstacles between the instrument and the target when taking measurements Note When you need to take measurements across a road or a place where vehicles or other objects are frequently moving take several measurements to a target for the best result Target You can measure approximately Traffic signs reflectors 500 meters 1640 feet Paper white veneer new 300 meters 990 feet wall brightly painted brick 100 to 200 meters 330 to 660 feet 2 Preparation 30 Trimble M3 DR Series Total Station User Guide Setting up the prism reflector 1 Assemble the prism reflector as shown below 2 Adjust the height of the tribrach adaptor see page 31 3 If necessary change the direction of the prism see page 31 4 If you are using a single prism holder set the position of the target plate see page 31 Detailed instructions for Step 2 through Step 4 are provided on the following pages Note You must use the Trimble M3 DR instruments with the Tribrach W30 or W30b Tribrach Tribrach
10. dusty places in direct sunlight or near heat sources Do not recharge the battery pack when it is wet If you do you may receive electric shocks or burns or the battery pack may overheat or catch fire C WARNING Although the battery pack has an auto reset circuit breaker you should take care not to short circuit the contacts Short circuits can cause the battery pack to catch fire or burn you C WARNING Never burn or heat the battery Doing so may cause the battery to leak or rupture A leaking or ruptured battery can cause serious injury C WARNING Before storing the battery pack or battery charger cover the contact points with insulation tape If you do not cover the contact points the battery pack or charger may short circuit causing fire burns or damage to the instrument C WARNING The battery itself is not waterproof Do not get the battery wet when it is removed from the instrument If water seeps into the battery it may cause a fire or burns 11 2Cautions Before using the instrument read the following cautions and follow the instructions that they provide C CAUTION Use of controls adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure C CAUTION The tips of the tripod ferrules are very sharp When handling or carrying the tripod take care to avoid injuring yourself on the ferrules C CAUTION Before carryi
11. in IEC60825 1 2007 Safety of Laser Products C CAUTION To counteract hazards it is essential for all users to pay careful attention to the safety precautions and control measures specified in the standard IEC60825 1 2007 within the hazard distance particularly as described in the User Guide C WARNING Only qualified and trained persons should be assigned to install adjust and operate the laser equipment C WARNING Areas in which these lasers are used should be posted with an appropriate laser warning sign C WARNING Precautions should be taken to ensure that persons do not look directly with or without an optical instrument into the beam Trimble M3 DR Series Total Station User Guide 7 Safety and Warnings C WARNING The laser beam should be terminated at the end of its useful beam path and should in all cases be terminated if the hazardous beam path extends beyond the limit hazard distance of the area in which the presence and activities of personnel are monitored for reasons of protection from laser radiation C WARNING Laser beam path should be located well above or below eye level wherever practicable C WARNING When the laser product is not used it should be stored in a location where unauthorized personnel cannot gain access C WARNING Do NOT turn the class 3R laser beam to mirror like specular surfaces for instance prisms metal surfaces or windows even uni
12. shown in Figure 6 1 on page 56 use of this connector is at your own risk C CAUTION Use only the male connectors specified above Using other connectors will damage the instrument The external device connector is a Hirose HR 10A 7R 6S female connector The pinouts for connecting it to an external device connector are shown below C CAUTION Use only the pin connections shown above Using other connections will damage the instrument C CAUTION The Trimble M3 DR total station has different pin assignment from other models of Nikon total station To connect to an external power source supply power to Pin 4 power terminal and Pin 5 ground terminal on the instrument The instrument will use the external power source even if the internal battery packs are attached C CAUTION Make sure that the power supplied is within the rated input range 4 5 V to 5 2 V DC 1 A maximum Power supplied outside this range will damage the instrument Input voltage 4 5 V to 5 2 V DC System RS 232C Signal level 9 V standard Maximum baud rate 38400 bps asynchronous Compatible male connector Hirose HR10A 7P 6P or HR10 7P 6P Pin Signal Description 1 RXD Receive data Input 2 TXD Send data Output 3 NC No connection 4 V Power 5 GND Ground 6 NC No connection HRS 1 6 2 5 3 4 Trimble M3 DR Series Total Station User Guide 53 Specifications 5 To communicate with an extern
13. 51 Environmental protection 51 Standard components 51 External device connector 52 6 System Diagrams 55 System components 56 C H A P T E R 1 Trimble M3 DR Series Total Station User Guide 13 Introduction 1 In this chapter Parts of the instrument Maintenance This instruction manual was written for the users of Trimble M3 DR Series total station instruments Before you operate a Trimble M3 DR series instrument read this manual carefully In particular pay attention to the warnings and cautions that appear in the Safety section at the front of the manual Before you begin you should also read the maintenance instructions For more information see Maintenance page 16 1 Introduction 14 Trimble M3 DR Series Total Station User Guide Parts of the instrument Figure 1 1 and Figure 1 2 show the main parts of the Trimble M3 DR series instrument Figure 1 1 Trimble M3 DR Series total station Face 1 Telescope Telescope Diopter ring Face 1 display Vertical tangent Battery box Upper
14. DR 1 2 40 mm 1 57 in EDM 45 mm 1 77 in Trimble M3 DR 3 5 45 mm 1 77 in EDM 50 mm 1 97 in Image Erect Field of view 1 20 2 3 m at 100 m 2 3 ft at 100 ft Resolving power 3 0 Focusing distance 1 5 m to infinity 4 92 ft to infinity Trimble M3 DR 1 2 Prism mode Reflector sheet 5 cm x 5 cm 270 m 886 ft Standard prism 1P 3 000 m 9 840 ft Reflectorless mode Reference target 300 m 984 ft Trimble M3 DR 3 5 Prism mode Reflector sheet 5 cm x 5 cm 300 m 984 ft Standard prism 1P 5 000 m 16 400 ft Reflectorless mode Reference target 300 m 984 ft Trimble M3 DR Series Total Station User Guide 47 Specifications 5 Distance precision Trimble M3 DR 1 2 Precise mode Prism 2 2 ppm D mm Reflectorless 3 2 ppm D mm Normal mode Prism 10 5 ppm D mm Reflectorless 10 5 ppm D mm ISO17123 4 for Prism measurement Trimble M3 DR 3 5 Precise mode Prism 3 2 ppm D mm 10 C to 40 C 3 3 ppm D mm 20 C to 10 C 40 C to 50 C Reflectorless 3 2 ppm D mm 10 C to 40 C 3 3 ppm D mm 20 C to 10 C 40 C to 50 C Normal mode Prism 10 5 ppm D mm Reflectorless 10 5 ppm D mm 5 Specifications 48 Trimble M3 DR Series Total Station User Guide Measurement int
15. SC key to cancel the adjustment Reset Tap Reset The Restart screen appears Reset stops the program in process and initializes the total station Use this menu when the application program does not run normally because of an unexpected reason Tap Yes button to execute Reset Tap No button to cancel the Reset and return to the screen shown before pressing the Power key Note Once the Reset is executed data that are not stored in the application program will be lost Trimble M3 DR Series Total Station User Guide 37 Getting Started 3 Shut down Tap Shutdown A warning screen appears Tap Yes to shut down the device Tap No to cancel the shut down and return to the screen shown before pressing the Power key Note Shut down completely turns off the total station It ends the application program and data that was not stored in the program is lost Auto power off setting Auto power off function saves the consumption of electricity by switching the total station to the standby mode when it is not operated for a certain time Tap the Windows button to display the menu and then select Settings Control Panel Double click the Power icon The latest battery status is displayed Select the Power Off tab The Time Settings window is displayed 3 Getting Started 38 Trimble M3 DR Series Total Station User Guide Select the Suspend after check box in the Idle Time Settings field Select the
16. USER GUIDE Trimble M3 DR Series Total Station Version 1 00 Revision D February 2013 F USER GUIDE Trimble M3 DR Series Total Station Trimble M3 DR 1 Trimble M3 DR 2 Trimble M3 DR 3 Trimble M3 DR 5 Contact Information Trimble Navigation Limited Engineering and Construction Division 5475 Kellenburger Road Dayton Ohio 45424 1099 USA 800 538 7800 toll free in USA 1 937 245 5600 Phone 1 937 233 9004 Fax www trimble com Copyright and Trademarks 2005 2012 Nikon Trimble Co Limited All rights reserved Trimble the Globe and Triangle logo and Terramodel are trademarks of Trimble Navigation Limited registered in the United States and in other countries TRIMMARK and TRIMTALK are trademarks of Trimble Navigation Limited Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries All other trademarks are the property of their respective owners It is prohibited to alter this manual in part or whole without express permission The contents of this manual are subject to change without notice Although every effort has been made to ensure the accuracy of this manual please contact your dealer if you find anything in it that is incorrect or unclear Release Notice This is the February 2013 revision D release of the Trimble M3 DR Series Total Station User Guide It applies to version 1 0x of the Trimble M3 total st
17. User Guide Checking the instrument constant The instrument constant is a numerical value used to automatically correct for the displacement between the mechanical and electrical centers when measuring distances The instrument constant is set by the manufacturer before the instrument is shipped However to ensure the highest operational accuracy we recommend that you check the instrument constant several times a year To check the instrument constant you can either compare a correctly measured base line with the distance measured by the EDM or follow the procedure below To check the instrument constant 1 Set up the instrument at Point P in as flat an area as possible 2 Set up a reflector prism at Point Q 100 m away from Point P Make sure that you take the prism constant into account 3 Measure the distance between Point P and Point Q PQ 4 Install a reflector prism on the tripod at Point P 5 Set up another tripod at Point R on the line between Point P and Point Q 6 Transfer the Trimble M3 DR series instrument to the tripod at Point R 7 Measure the distance from Point R to Point P RP and from Point R to Point Q RQ 8 Calculate the difference between the value of PQ and the value of RP RQ 9 Move the Trimble M3 DR series instrument to other points on the line between Point P and Point Q 10 Repeat Step 5 through Step 9 ten times or so 11 Calculate the average of all the difference
18. al device connect the RS 232C signal from the external device to Pin 1 input terminal and to Pin 2 output terminal on the instrument Cap the data output external power input connector securely while not in use The instrument is not watertight if the cap is not attached or not attached securely and when the data output external power input connector is in use The instrument can be damaged by static electricity from the human body discharged through the data output external power input connector Before handling the instrument touch any other conductive material once to remove static electricity 5 Specifications 54 Trimble M3 DR Series Total Station User Guide C H A P T E R 6 Trimble M3 DR Series Total Station User Guide 55 System Diagrams 6 In this chapter System components 6 System Diagrams 56 Trimble M3 DR Series Total Station User Guide System components Figure 6 1 Measurement side attachment Trimble M3 Connecting cable Personal computer Diagonal Battery charger Low power eyepiece High power eyepiece Solar filter AC adapter and plug adapter 9 pin USB USB cable USB memory eyepiece Personal computer DR series Trimble M3 DR Series Total Station User Guide 57 System Diagrams 6 Figure 6 2 Prism reflector side Note You must use the Tribrach W30 or W30b with the Trimble M3 DR series instruments Mini prism C Mini prism holder Mini prism
19. arging may take up to 5 hours with a completely drained battery which has been stored for several months without use By design Li Ion batteries should not be charged above 40 C 45 C so a blinking charge light may mean the batteries are too hot for charging Charging will resume after the batteries cool down The charging time will be longer due to the batteries cool down when charging batteries above 40 C 45 C Charge indicator 0 Calibration indicator 0 Calibration button Calibration indicator 1 Charge indicator 1 Power jack This will read 5V 4A Case Top edge Battery Slot 0 Battery Slot 1 Trimble M3 DR Series Total Station User Guide 23 Preparation 2 If the charge indicator s are blinking and the batteries feel cool it may indicate a problem with the battery or the charger If the charge light is still blinking after trying several batteries which are not warm there is a problem with the unit or the batteries themselves Conditioning calibrating a battery Battery calibration is necessary about once every 6 months or more often if desired Calibration insures the reported battery charge remaining is accurate Hold down the calibration button on the unit and then insert a battery while holding the calibration button to begin a battery calibration Only the battery which was inserted while the button was depressed will begin calibration During a battery calibration the bat
20. ation Manufacturer Nikon Trimble Co Ltd Technoport Mituiseimei Bldg 16 2 Minamikamata 2 chome Ota ku Tokyo 144 0035 Japan Notices USA FCC 15B Class B satisfied This equipment has been tested and found to comply with the limits for a Class B personal computer and peripherals pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help C WARNING This equipment has been certified to comply with the limits for a Class B personal computer and peripherals pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer
21. circuit breaker you should take care not to short circuit the contacts Short circuits can cause the battery pack to catch fire or burn you C WARNING Never burn or heat the battery Doing so may cause the battery to leak or rupture A leaking or ruptured battery can cause serious injury C WARNING Before storing the battery pack or battery charger cover the contact points with insulation tape If you do not cover the contact points the battery pack or charger may short circuit causing fire burns or damage to the instrument C WARNING The battery is not itself waterproof Do not get the battery wet when it is removed from the instrument If water seeps into the battery it may cause a fire or burns 2 Preparation 22 Trimble M3 DR Series Total Station User Guide Applying power Plug in the charger to the supplied AC adapter to turn the unit on The power input must be 5 V with at least 4 A of current capability Each battery may take up to 2 A while charging Charging a battery Simply slide a battery into either battery slot to begin charging The adjacent charge indicator will illuminate yellow when charging is in progress The charge indicator will change to green when charging is complete Charger slots are completely independent so a battery may be inserted regardless of the state of the other battery slot Charging may take 2 4 hours if the battery was normally discharged Ch
22. e multiple reflections on the prism surface can sometimes cause a significant loss in accuracy To maintain the accuracy of your measurements when measuring a short distance incline the prism slightly so that the EDM can ignore unnecessary reflections on the prism surface as shown below Target Target setting Prism reflector sheet Prism Prism mode Other reflective materials N Prism Reflectorless mode thin edges chipped center thick edges 3 5 5 Trimble M3 DR Series Total Station User Guide 29 Preparation 2 Note Hold the prism securely in place and do not move while taking measurements Note In Prism mode in order to avoid false measurements on objects other than the prism or reflector sheet targets that are less reflective than the prism or reflector sheet are not measured Even if you start a measurement measured values are not displayed To measure less reflective objects use the N prism reflectorless mode Measurement in reflectorless mode The intensity of the reflection from the target determines the distance the Trimble M3 DR instruments can measure in this mode The color and condition of the target surface also affect the measurable distance even if the targeted objects are the same Some less reflective targets may not be measured The following table describes some examples of targets and approximate measurable distances Measurable distances may be shorter or measurement intervals may
23. e tripod mounting screw Note Do not carry the instrument while it is attached to a tripod Centering When you center the instrument you align its central axis precisely over the station point To center the instrument you can either use the laser plummet or a plumb bob Centering using the laser plummet Note Do NOT look into the laser directly Note If you require high accuracy check and adjust the laser plummet before you center the instrument For detailed instructions see Checking and adjusting the circular level page 40 1 Set up the instrument on the tripod For detailed instructions see Setting up the tripod page 25 2 Turn on the laser plummet 3 Align the laser pointer to the station point To do this turn the leveling screws until the laser pointer is over the station point 4 While supporting the tripod head with one hand loosen the tripod leg clamps and adjust the lengths or the legs until the air bubble is the center of the circular level 5 Tighten the tripod leg clamps 6 Use the electronic level to level the instrument For detailed instructions see Leveling page 26 7 Check the laser pointer is over the station point 2 Preparation 26 Trimble M3 DR Series Total Station User Guide 8 If the station point is off center do one of the following If the station point is slightly off center loosen the tripod mounting screw and then center the instrument on the tri
24. ed characters Clean these parts only with a soft cloth or a tissue lightly moistened with water or a mild detergent To clean the optical lenses lightly wipe them with a soft cloth or a lens tissue that is moistened with alcohol The reticle plate cover has been correctly mounted Do not release it or subject it to excessive force to make it watertight Before attaching the battery pack check that the contact surfaces on the battery and instrument are clean Securely press the cap that covers the data output external power input connector terminal The instrument is not watertight if the cap is not attached securely or when the data output external power input connector is used Reticle plate cover Trimble M3 DR Series Total Station User Guide 17 Introduction 1 The carrying case is designed to be watertight but you should not leave it exposed to rain for an extended period If exposure to rain is unavoidable make sure that the carrying case is placed with the Nikon nameplate facing upward The battery pack contains a Lithium ion battery When disposing of the battery pack follow the laws or rules of your municipal waste system The instrument can be damaged by static electricity from the human body discharged through the data output external power input connector Before handling the instrument touch any other conductive material once to remove static electricity Be careful not to p
25. er Height adjustment adapter clamp screw Clamp Clamp lever Unclamp Center on axis 2 Preparation 32 Trimble M3 DR Series Total Station User Guide C H A P T E R 3 Trimble M3 DR Series Total Station User Guide 33 Getting Started 3 In this chapter Turning the instrument ON and OFF Basic operation 3 Getting Started 34 Trimble M3 DR Series Total Station User Guide Turning the instrument ON and OFF Turning on the instrument Press the Power key to turn on the instrument and the application program will start up Refer to the operation manual for how to use the application program Note Check that the batteries are correctly inserted into the slot if the application program does not start when you have pressed the Power key Turning off the instrument Press the Power key The Power Key screen appears Tap the Standby button to turn off the instrument Tap OK to close the screen The display returns to the screen shown before you pressed the Power key Note Standby is the function that stops the program running and turns off the instrument When you press the Power key again you are returned to the screen displayed before the instrument is turned off Trimble M3 DR Series Total Station User Guide 35 Getting Started 3 Basic operation C CAUTION Use the stylus provided with the Trimble M3 DR series on the touch screen Any other stylus may damage t
26. ervals Measurement intervals may vary with the measuring distance or weather conditions For the initial measurement it may take few more seconds Angle measurement Tilt sensor Trimble M3 DR 1 2 Precise mode Prism 1 6 sec Reflectorless 2 1 sec Normal mode Prism 1 2 sec Reflectorless 1 2 sec Prism offset correction 999 mm to 999 mm 1 mm step Trimble M3 DR 3 5 Precise mode Prism 1 5 sec Reflectorless 1 8 sec Normal mode Prism 0 8 sec Reflectorless 1 0 sec Prism offset correction 999 mm to 999 mm 1 mm step Reading system Absolute encoder Diametrical reading on HA VA Minimum display increment 360 1 5 10 400G 0 2 mgon 1 mgon 2 mgon MIL6400 0 005 MIL 0 02 MIL 0 05 MIL DIN18723 accuracy Trimble M3 DR 1 1 0 3 mgon Trimble M3 DR 2 2 0 6 mgon Trimble M3 DR 3 3 1 0 mgon Trimble M3 DR 5 5 1 5 mgon Method Liquid electric detection Dual axis Compensation range 3 Trimble M3 DR Series Total Station User Guide 49 Specifications 5 Tangent screw Tribrach Level Optical plummet Trimble M3 DR 1 only Laser plummet Trimble M3 DR 2 3 5 Display and keypad Trimble M3 DR 1 Clamp system Trimble M3 DR 2 3 5 Friction clutch endless fine motion Type Detachable Electronic level Displayed on the LCD Circular level vial Sensitivity 10 2 mm Image E
27. following conventions are used to indicate safety instructions C WARNING Warnings alert you to situations that could cause death or serious injury C CAUTION Cautions alert you to situations that could cause injury or property damage Always read and follow the instructions carefully 11 1Warnings Before using the instrument read the following warnings and follow the instructions that they provide C WARNING Never look at the sun through the telescope If you do you may damage or lose your eyesight C WARNING The Trimble M3 total station is not designed to be explosion proof Do not use the instrument in coal mines in areas contaminated with coal dust or near other flammable substances C WARNING Never disassemble modify or repair the instrument yourself If you do you may receive electric shocks or burns or the instrument may catch fire C WARNING Use only the battery charger and AC adapter that are supplied with the instrument Do not use any other charger as you may cause the battery pack to catch fire or rupture Safety and Warnings 4 Trimble M3 DR Series Total Station User Guide C WARNING Do not cover the battery charger and AC adapter while the battery pack is being recharged The charger must be able to dissipate heat adequately Coverings such as blankets or clothing can cause the charger to overheat C WARNING Avoid recharging the battery pack in humid or
28. he touch screen C CAUTION Lightly tap the touch screen with the stylus Otherwise you may damage the touch screen Turning on and off the Backlight Press the Power key The Power Key screen appears Tap Backlight On Off to switch the back lighton off Tap OK to close the screen The display returns to the screen shown before you pressed the Power key Other functions Press the Power key The Power Key screen appears Press Options to display the option menu For an explanation of the different options see below Tap OK to close the screen The display returns to the screen shown before you pressed the Power key 3 Getting Started 36 Trimble M3 DR Series Total Station User Guide Cleaning the touch screen Tap Clean Touch Screen to disable the touch screen Do this when you want to clean the touch panel Press Enter key and the display returns to the screen shown before you pressed the Power key Adjusting the touch screen Tap Adjust Touch Screen to show the touch panel adjustment window By following the instruction in this window a gap between the actual tapping point and button on the window is corrected Use the stylus to press the plus sign on the screen for 1 second The sign moves to a corner of the screen when you remove the stylus Press Enter key after you pressed in the center and four corners to complete the adjustment of touch screen Press the E
29. ice Operation is subject to the following two conditions 1 This device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device European Union countries Iceland Norway Liechtenstein Turkey Swiss EN300 328v1 7 1 EN50360 satisfied Hereby Nikon Trimble Co Ltd declares that this instrument is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Declaration of Conformity available at http www nikon trimble com RF exposure compliance 1 To comply with FCC IC RF exposure compliance requirements a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons 2 This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Trimble M3 DR Series Total Station User Guide 3 Safety and Warnings For your safety read the safety and warnings and this user guide carefully and thoroughly before using the Trimble M3 DR series total station Although Trimble products are designed for maximum safety using them incorrectly or disregarding the instructions can cause personal injury or property damage You should also read the documentation for any other equipment that you use with a Trimble M3 total station Note Always keep the manual near the instrument for easy reference 1 1 Warnings and Cautions The
30. inch your finger between the telescope and trunnion of the instrument Use the stylus provided with the Trimble M3 DR series on the touch screen Any other stylus may damage the touch screen Lightly tap the touch screen with the stylus Otherwise you may damage the touch screen 1 Introduction 18 Trimble M3 DR Series Total Station User Guide C H A P T E R 2 Trimble M3 DR Series Total Station User Guide 19 Preparation 2 In this chapter Unpacking and packing the instrument Charging the battery pack Detaching and re attaching the battery pack Setting up the tripod Centering Leveling Sighting Setting the measurement mode and preparing the target Measurement in reflectorless mode Setting up the prism reflector 2 Preparation 20 Trimble M3 DR Series Total Station User Guide Unpacking and packing the instrument Note Handle the Trimble M3 DR series instrument gently to protect it from shocks and excessive vibration Unpacking To unpack the instrument grip the carrying handle and carefully remove the instrument from the carrying case Packing To pack the instrument back into the carrying case see the figure on the right Note The Trimble M3 DR 1 has a different carrying case Charging the battery pack Before charging the battery pack read the warnings also listed in the Safety section at the front of this manual
31. input output devices terminals printers etc certified to comply with the Class B limits may be attached to this equipment Operation with non certified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment European Union EU EMC Directive satisfied Authorized Representative in Europe Trimble GmbH Am Prime Parc 11 65479 Raunheim Germany Canada This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la Class B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Recycling Taiwan Battery Recycling Requirements The product contains a removable battery Taiwanese regulations require that waste batteries are recycled Notice to Our European Union Customers For product recycling instructions and more information please go to www trimble com environment summary html Recycling in Europe To recycle Trimble WEEE call 31 497 53 2430 and ask for the WEEE associate or mail a request for recycli
32. ipment can cause an explosion or fire and can result in personal injury and or equipment damage To prevent injury or damage Do not charge or use the battery if it appears to be damaged or leaking Charge the Lithium ion battery only in a product that is specified to charge it Be sure to follow all instructions that are provided with the battery charger Discontinue charging a battery that gives off extreme heat or a burning odor Use the battery only in equipment that is specified to use it Use the battery only for its intended use and according to the instructions in the product documentation C WARNING To charge the battery pack use only the battery charger and AC adapter that are supplied with the instrument Do NOT use any other charger or you may cause the battery pack to catch fire or rupture The enclosed battery pack cannot be used with other chargers C WARNING Do not cover the battery charger and AC adapter while the battery pack is being recharged The charger must be able to dissipate heat adequately Coverings such as blankets or clothing can cause the charger to overheat C WARNING Avoid recharging the battery pack in humid or dusty places in direct sunlight or near heat sources Do not recharge the battery pack when it is wet If you do you may receive electric shocks or burns or the battery pack may overheat or catch fire C WARNING Although the battery pack has an auto reset
33. le cross hairs If the target image does not move there is no parallax d If the target image does move rotate the telescope focusing ring Then repeat from Step c 3 Rotate the tangent screw The final turn of the tangent screw should be in a clockwise direction to align the target accurately on the center cross hairs C B A 2 Bottom edge of the keyboard panel Center crosshairs Diopter ringTelescope focusing ring 2 Preparation 28 Trimble M3 DR Series Total Station User Guide Setting the measurement mode and preparing the target The Trimble M3 DR series total station has two measurement modes Prism mode Prism and Reflectorless mode N Prism To set the measurement mode depending on the target you want to measure see the following table In some cases you can measure another target that is not appropriate to the set measurement mode Note The Trimble M3 DR 1 and 2 total station is Laser Class 3R in the Reflectorless mode and Laser pointer function and Laser Class 1 in the Prism mode Do not sight the Prism when the Laser Pointer is on Note The Trimble M3 DR 3 and 5 total stations are Laser Class 1 in the Prism and Reflectorless mode and Laser Class 2 in Laser pointer function Measurement with a prism Do not use a prism with scratches a dirty surface or a chipped center Prisms with thin edges are recommended As the Trimble M3 DR instruments are extremely sensitiv
34. lease knob counterclockwise open the battery box cover and remove the battery pack from the battery box Inserting the battery pack Before inserting the battery pack clear any dust or other foreign particles from the battery contacts 1 Turn the battery box release knob counterclockwise and open the battery box cover 2 Put the battery pack into the battery box Insert the battery pack with the connectors bottom first facing inside 3 Close the battery box cover and turn the knob clockwise until the secure click sound is heard C CAUTION If the battery box cover is not closed this could adversely affect the watertightness of the instrument 2 1 3 Trimble M3 DR Series Total Station User Guide 25 Preparation 2 Setting up the tripod C CAUTION The tips of the tripod ferrules are very sharp When handling or carrying the tripod take care to avoid injuring yourself on the ferrules 1 Open the tripod legs enough to for the instrument to be stable 2 Locate the tripod directly over the station point To check the tripod s position look through the center hole in the tripod head 3 Firmly press the tripod ferrules into the ground 4 Level the top surface of the tripod head 5 Securely fasten the thumb screws on the tripod legs 6 Place the instrument on the tripod head 7 Insert the tripod mounting screw into the center hole of the base plate of the instrument 8 Tighten th
35. level use the adjusting pin to rotate the three adjustment screws of either circular level on the instrument main body or tribrach until the bubble is centered Checking and adjusting the optical laser plummet The optical axis of the plummet must be aligned with the vertical axis of the instrument To check and adjust the optical laser plummet 1 Place the instrument on the tripod You do not have to level the instrument 2 Place a thick sheet of paper marked with an X on the ground below the instrument While you are looking through the optical plummet adjust the leveling screws until the image of the X is in the center of the reticle mark For laser plummet adjust the laser pointer to the X 3 Rotate the alidade 180 If the marked image is in the same position in the center of the reticle mark no adjustment is required For a laser plummet if the laser pointer is on the X no adjustment is required P Trimble M3 DR Series Total Station User Guide 41 Checking and Adjustment 4 4 If the image or laser pointer is not in the same position adjust the laser plummet Note For laser plummet adjustment you must remove the cap a Use the supplied hexagonal wrench to turn the adjustment screws until the image of the X is in Position P Position P is the center point of the line connecting the X and the center of the reticle mark b Repeat from Step 2 Zero point errors of vertical scale and horizo
36. ling screws B and C to move the bubble into the center of the electronic level 4 Rotate the alidade approximately 90 B C A 1 Bottom edge of the keyboard panel Trimble M3 DR Series Total Station User Guide 27 Preparation 2 5 Use leveling screw A to move the bubble into the center of the electronic level 6 Repeat Step 1 through Step 5 to center the bubble in both positions 7 Rotate the alidade 180 8 If the bubble in the electronic level remains centered the instrument is level If the bubble moves off center adjust the electronic level For detailed instructions see Adjusting the electronic level page 40 Sighting When you sight the instrument you aim the telescope at the target bring the target image into focus and align the image with the center cross hairs of the reticle To sight the instrument 1 Adjust the diopter a Aim the telescope at a blank area such as the sky or a piece of paper C WARNING Never look at the sun through the telescope If you do you may damage or lose your eyesight b Looking through the eyepiece rotate the diopter ring until the reticle cross hairs are in sharp focus 2 Eliminate parallax a Aim the telescope at the target image b Rotate the focusing ring until the target image is in sharp focus on the reticle cross hairs c Move your eye vertically and laterally to check whether the target image moves relative to the retic
37. m in the instrument may stop functioning in order to avoid any errors in measurement when the instrument detects strong electromagnetic wave s If this is the case turn off the instrument and remove the source of the electromagnetic wave s Then turn on the instrument to resume the work C CAUTION Use the stylus provided with the Trimble M3 DR series on the touch screen Any other stylus may damage the touch screen C CAUTION Lightly tap the touch screen with the stylus Otherwise you may damage the touch screen 1 2 Rechargeable Lithium ion Li ion batteries C WARNING Do not damage the rechargeable Lithium ion battery A damaged battery can cause an explosion or fire and can result in personal injury and or property damage To prevent injury or damage Do not use or charge the battery if it appears to be damaged Signs of damage include but are not limited to discoloration warping and leaking battery fluid Do not expose the battery to fire high temperature or direct sunlight Do not immerse the battery in water Do not use or store the battery inside a vehicle during hot weather Do not drop or puncture the battery Do not open the battery or short circuit its contacts Safety and Warnings 6 Trimble M3 DR Series Total Station User Guide C WARNING Avoid contact with the rechargeable Lithium ion battery if it appears to be leaking Battery fluid is corrosive and contact with it can
38. ng instructions to Trimble Europe BV c o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel NL Bluetooth unit USA FCC Part 15 Subpart C RSS 210 OET bulletin 65 supplement C satisfied C WARNING Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canada RSS 210 Low Power Dev
39. ng the tripod or the instrument in the carrying case check the shoulder strap and its clasp If the strap is damaged or the clasp is not securely fastened the carrying case may fall causing personal injury or instrument damage C CAUTION Before setting up the tripod make sure that no one s hands or feet are underneath it When the legs of the tripod are being driven into the ground they could pierce hands or feet Trimble M3 DR Series Total Station User Guide 5 Safety and Warnings C CAUTION After mounting the instrument on the tripod securely fasten the thumb screws on the tripod legs If the thumb screws are not securely fastened the tripod may collapse causing personal injury or instrument damage C CAUTION After mounting the instrument on the tripod securely fasten the clamp screw on the tripod If the clamp screw is not securely fastened the instrument may fall off the tripod causing personal injury or instrument damage C CAUTION Securely fasten the tribrach clamp knob If the knob is not securely fastened the tribrach may come loose or fall off when you lift the instrument causing personal injury or instrument damage C CAUTION Do not stack objects on the plastic carrying case or use it as a stool The plastic carrying case is unstable and its surface is slippery Stacking or sitting on the plastic carrying case may cause personal injury or instrument damage C CAUTION The syste
40. ntal angle corrections Checking 1 Set up the instrument on the tripod 2 Follow the leveling procedures described in Leveling page 26 3 Flip the telescope to the Face 1 position 4 Sight a target that is within 45 of the horizontal plane 5 Read the vertical angle from the VA1 field in the Basic Measurement Screen BMS 6 Rotate the instrument 180 and flip the telescope to the Face 2 position 7 Read the vertical angle from the VA2 field 8 Add the two vertical angles together VA1 VA2 No adjustment is required if the zero reference for vertical angles VA zero setting is set to Zenith and VA1 VA2 equals 360 No adjustment is required if the zero reference for vertical angles VA zero setting is set to Horizon and VA1 VA2 is either 180 or 540 An adjustment is required if VA1 VA2 is not one of the values listed above Note The difference between the vertical angle reading the relevant angle either 360 for Zenith or 180 or 540 for Horizon is called the altitude constant Adjusting The calibration procedure is contained in the Trimble Access application software To perform the adjustment select Trimble Access General Survey Instrument Adjust For more information refer to the Trimble Access Help files These can be found at www trimble com survey Trimble Access IS support aspx 4 Checking and Adjustment 42 Trimble M3 DR Series Total Station
41. ntentionally Special precautions should be taken to ensure eliminating such situations The hazard distance is the distance from the laser at which beam irradiance or radiant exposure equals the maximum permissible value to which personnel may be exposed without being exposed to health risk 13 1Trimble M3 DR 1 and 2 total stations Specifications for laser emissions Conforming standards Laser pointer Class 3R Wave length 630 680 nm Output power CW Po 4 75 mW Distance meter in Reflectorless mode Class 3R Wave length 630 680 nm Output power pulse Pp 8 75 mW Po 4 75 mW 1 2 nsec 400 MHz 1 6 nsec 320 MHz Distance meter in Prism mode Class 1 Wave length 630 680 nm Output power pulse Pp 0 037 mW Po 0 02 mW 1 2 nsec 400 MHz 1 6 nsec 320 MHz Laser plummet Class 2 DR 2 only Wave length 635 nm Output power CW Po lt 1 0 mW E U IEC60825 1 2007 Class 3R USA FDA21CFR Part 1040 Sec 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated 24 June 2007 Safety and Warnings 8 Trimble M3 DR Series Total Station User Guide 13 2Trimble M3 DR 3 and 5 total stations Specifications for laser emissions Conforming standards 13 3Instrument labels Laser labels Laser pointer Class 2 Wave length 630 680 nm Output power CW Po 1 mW Distance meter Class 1 Wave length 850 890 nm Output power Pulse Po 6 4 W Pulse width l
42. ough 140 F Winterized version Operating temperature range 30 C through 50 C 22 F through 122 F Storage temperature range 30 C through 60 C 22 F through 140 F Main unit 149 mm W x 158 5 mm D x 308 mm H Carrying case for DR 2 3 5 470 mm W x 231 mm D x 350 mm H Carrying case for DR 1 435 mm W x 206 mm D x 297 mm H Trimble M3 DR Series Total Station User Guide 51 Specifications 5 Weight Environmental protection Standard components Instrument main body Battery pack x 2 Battery charger AC adapter Adjustment pin Allen wrench Vinyl cover Trimble M3 DR Series Total Station User Guide this document Carrying case Shoulder strap USB cable x 1 Main unit without battery 4 1 kg 9 0 lbs Battery 0 1 kg 0 2 lbs Carrying case 3 3 kg 7 3 lbs for DR 2 3 5 2 3 kg 5 1 lbs for DR 1 Charger and AC adapter 0 4 kg 0 9 lbs approx Watertight dust proof protection IP66 for DR 2 3 5 IP56 for DR 1 5 Specifications 52 Trimble M3 DR Series Total Station User Guide External device connector This connector can be used to connect to an external power source or to communicate with an external device Before using the external device connector make sure that the external device meets the specifications below C CAUTION Except for the connection
43. plate screw tangent screw focusing ring eyepiece keyboard Carrying handle Optical sight Finder Reticle plate Label for CFR Tribrach clamp knob Battery box release knob Label for FCC USB ports Stylus pen This figure shows the Trimble M3 DR 5 instrument Laser class label cover Trimble M3 DR Series Total Station User Guide 15 Introduction 1 Figure 1 2 Trimble M3 DR Series total station Face 2 Horizontal axis indication mark Objective Battery box LASER LIGHT IS EMITTED FROM THIS PART Data output external power input connector Input voltage shall be Circular level Battery box release knob Leveling screw Tribrach Laser class label Laser plummet 4 5 5 2 V DC Laser aperture Laser class label label This figure shows the Trimble M3 DR 5 instrument Lumi guides 1 Introduction 16 Trimble M3 DR Series Total Station User Guide Maintenance Before using the instrument read and follow the following maintenance instructions Do not leave the instrument in direct sunlight or in a closed vehicle for prolonged periods Overheating the instrument may reduce its efficiency If the Trimble M3 DR series instrument has been used in wet conditions immediately wipe off any moisture and dry the instrument completely before returning the instrument to the carrying case The instrument contains sensitive electronic assemblies which ha
44. pod Use only direct movement to center the instrument Do not rotate it When the instrument is centered tighten the mounting screw If the displacement of the station point is major repeat this procedure from Step 2 Centering using a plumb bob 1 Set up the instrument on the tripod For detailed instructions see Setting up the tripod page 25 2 Hang the plumb line on the hook of the tripod mounting screw 3 Adjust the length of the plumb line so that the tip of the plumb bob is at the height of the station point 4 Loosen the tripod mounting screw slightly 5 Using both hands to support the outer side of the tribrach carefully slide the instrument about on the tripod head until the tip of the plumb bob is positioned over the exact center of the station point Note To confirm that the instrument is precisely aligned check its position from two directions at right angles to each other Leveling When you level the instrument you make the vertical axis of the instrument exactly vertical To level the instrument use the electronic level In the leveling work always set the instrument in face 1 direction please refer to the Fig 1 1 in page 3 To level the instrument 1 Move the bubble into the circle drawn on the circular level and then turn on the power 2 Rotate the alidade until the bottom edge of the keyboard panel is parallel to the two of the leveling screws B and C 3 Use leve
45. rect Magnification 3 x Field of view 5 Focusing range 0 5 m 1 6 ft to infinity Wave length 635 nm Laser class Class 2 Focusing range Laser diameter Approx 2 mm Face 1 display QVGA 16 bit color TFT LCD backlit 320 x 240 pixel Face 2 display Backlit graphic LCD 128 x 64 pixel Face 1 keys 22 keys Face 2 keys 4 keys 5 Specifications 50 Trimble M3 DR Series Total Station User Guide Connections in the instrument Battery pack Tested at 25 C nominal temperature Operation times may vary depending on the condition and deterioration of the battery Environmental performance Dimensions Communications RS 232C Maximum baud rate 38400 bps asynchronous USB Host and Client Class 2 Bluetooth 2 0 EDR External power supply input voltage 4 5 V to 5 2 V DC Output voltage 3 8 V DC rechargeable Continuous operation time Trimble M3 DR 1 2 Continuous distance angle measurement approx 12 hours Distance angle measurement every 30 seconds approx 26 hours Continuous angle measurement approx 28 hours Trimble M3 DR 3 5 Continuous distance angle measurement approx 7 5 hours Distance angle measurement every 30 seconds approx 16 hours Continuous angle measurement approx 20 hours Normal version Operating temperature range 20 C through 50 C 4 F through 122 F Storage temperature range 25 C through 60 C 13 F thr
46. result in personal injury and or property damage To prevent injury or damage If the battery leaks avoid contact with the battery fluid If battery fluid gets into your eyes immediately rinse your eyes with clean water and seek medical attention Do not rub your eyes If battery fluid gets onto your skin or clothing immediately use clean water to wash off the battery fluid C WARNING Charge and use the rechargeable Lithium ion battery only in strict accordance with the instructions Charging or using the battery in unauthorized equipment can cause an explosion or fire and can result in personal injury and or equipment damage To prevent injury or damage Do not charge or use the battery if it appears to be damaged or leaking Charge the Lithium ion battery only in a product that is specified to charge it Be sure to follow all instructions that are provided with the battery charger Discontinue charging a battery that gives off extreme heat or a burning odor Use the battery only in equipment that is specified to use it Use the battery only for its intended use and according to the instructions in the product documentation 1 3 Laser safety The Trimble M3 DR 1 and 2 total station is a Class 3R laser product as defined in IEC60825 1 2007 Safety of Laser Products Use of the Laser Class 3R equipment can be dangerous The Trimble M3 DR 3 and 5 total stations are Class 2 laser products as defined
47. s The error range is within 3 mm If the error is out of range contact your dealer About 100 m P Q P R Q Trimble M3 DR Series Total Station User Guide 43 Checking and Adjustment 4 Checking the laser pointer The Trimble M3 DR series total station uses a red laser beam to a laser pointer The laser pointer is coaxial with the line of sight of the telescope If the instrument is well adjusted the red laser pointer coincides with the line of sight External influences such as shock or large temperature fluctuations can displace the red laser pointer relative to the line of sight 4 Checking and Adjustment 44 Trimble M3 DR Series Total Station User Guide C H A P T E R 5 Trimble M3 DR Series Total Station User Guide 45 Specifications 5 In this chapter Main body Standard components External device connector 5 Specifications 46 Trimble M3 DR Series Total Station User Guide Main body Telescope Measurement range Distances shorter than 1 5 m 4 92 ft cannot be measured with this EDM Measurement range with no haze visibility over 40 km 25 miles The target should not receive direct sunlight Reference target refers to a white highly reflective material KGC90 The maximum measurement range of the DR 1 and DR 2 is 500 m in the reflectorless mode Tube length 125 mm 4 91 in Magnification 30 X Effective diameter of objective Trimble M3
48. t 5 ns Laser plummet Class 2 Wave length 635 nm Output power CW Po lt 1 0 mW E U IEC60825 1 2007 Laser Pointer Class 2 Distance Meter Class 1 Laser plummet Class 2 USA FDA21CFR Part 1040 Sec 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated 24 June 2007 Laser pointer and Laser pointer distance meter Trimble M3 DR 3 and 5 The distance meter of the DR 3 and 5 is Laser Class 1 There is no special label on the instrument Trimble M3 DR 2 3 and 5 Laser plummet This label is Trimble M3 DR 1 and 2 attached when the laser plummet is purchased Trimble M3 DR Series Total Station User Guide 9 Safety and Warnings CFR and FCC labels Label placement laser pointer distance meter laser plummet CFR label FCC label Label for laser pointer and distance meter DR 1 and DR 2 Label for laser pointer DR 3 and DR 5 Label for laser plummet DR 2 DR 3 and DR 5 Safety and Warnings 10 Trimble M3 DR Series Total Station User Guide Label placement FCC and CFR Trimble M3 DR Series Total Station User Guide 11 Contents Safety and Warnings 3 Warnings and Cautions 3 Warnings
49. tery will be charged discharged completely and then recharged before finishing Calibration should complete in roughly 17 hours and the charger vents should not be covered during a calibration cycle The blue calibration indicator light s will blink slowly on 1 5 sec off 2 sec while a calibration is in progress and the charge light s may be on or off during the calibration cycle When a calibration cycle is completed the calibration light will stop blinking remain on until the corresponding battery is removed The bottom case temperature may continue to climb up to approximately 43 C before temperature regulation is enabled to keep the case from getting warmer As the battery voltage drops the case will cool down and the automatic temperature limiting will no longer be necessary which minimizes the time it takes to discharge a battery If the case temperature continues to get too hot internally even after temperature regulation is enabled there is a secondary failsafe which will abort the calibration completely If an abort occurs the calibration light s will blink rapidly and battery charging will be re enabled 2 Preparation 24 Trimble M3 DR Series Total Station User Guide Detaching and re attaching the battery pack Detaching the battery pack C CAUTION Avoid touching the contacts on the battery pack 1 If the instrument is turned on press PWR to turn it off 2 Turn the battery box re
50. time from the drop down menu The options are 5 10 30 minutes The suspend mode check box is cleared if a time is not selected from the drop down menu Tap OK to complete the setting Note Suspend mode and standby mode are the same status Date Time settings This function allows date and time setting of the Total Station Tap the Windows button to display the menu and then select Settings Control Panel Double click the Date Time icon The current set date and time appear Set the date time and time zone Tap Apply to fix the set values Tap OK to complete the setting C H A P T E R 4 Trimble M3 DR Series Total Station User Guide 39 Checking and Adjustment 4 In this chapter Adjusting the electronic level Checking and adjusting the circular level Checking and adjusting the optical laser plummet Zero point errors of vertical scale and horizontal angle corrections Checking the instrument constant Checking the laser pointer 4 Checking and Adjustment 40 Trimble M3 DR Series Total Station User Guide Adjusting the electronic level Adjustment of the electronic level is done by Zero point errors of vertical scale and horizontal angle corrections For detailed instruction see page 41 Checking and adjusting the circular level Once you have checked and adjusted the electronic level check the circular level If the bubble is not in the center of the
51. ve been well protected against dust and moisture However if dust or moisture gets into the instrument severe damage could result Sudden changes in temperature may cloud the lenses and drastically reduce the measurable distance or cause an electrical system failure If there has been a sudden change in temperature leave the instrument in a closed carrying case in a warm location until the temperature of the instrument returns to room temperature Do not store the Trimble M3 DR series instrument in hot or humid locations In particular you must store the battery pack in a dry location at a temperature of less than 30 C 86 F High temperature or excessive humidity can cause mold to grow on the lenses It can also cause the electronic assemblies to deteriorate and so lead to instrument failure When storing the instrument in areas subject to extremely low temperatures leave the carrying case open When adjusting the leveling screws stay as close as possible to the center of each screw s range The center is indicated by a line on the screw If the tribrach will not be used for an extended period lock down the tribrach clamp knob and tighten its safety screw Do not use organic solvents such as ether or paint thinner to clean the non metallic parts of the instrument such as the keyboard or the painted or printed surfaces Doing so could result in discoloration of the surface or in peeling of print
Download Pdf Manuals
Related Search
Related Contents
Manual de Instalacao do SIHD2 no Win 7 Manual Operativo - Geral Lexmark X215 MFP Benutzerhandbuch Sony XR-C223 User's Manual TESZLA - Giesemann Manuel d`utilisation DPC Mode d`emploi Manuel d`Installation et de l`Utilisateur DN-6.7.2, DeviceNet Cable System, Planning and Installation Manual Copyright © All rights reserved.
Failed to retrieve file