Home
User Manual - RONDA Industrial Vacuum Cleaners
Contents
1. en 17 COLLECIION OF DRY DUST ess 18 ELECTRICAL OUTLET WITH AUTOMATIC START STOP cccccccecceccscescecceccecescesceccscescescesceccecescscesescescescescesescescceecs 18 CLEANING OF THE MULTI TUBE FILTER DURING OPERATION AS NEEDED OR WHEN THE ALARM BEEPS 20 5 ad ld DT OT a IR 21 REORDERING OF FILTER BAGS ccccccscsceccecceccsceccecceccscescescecceccecescescectecescecescscescescscsecscescesceccssescescescesescuececescens 22 DUST HAZARDOUS TO HEALTH AND ASBESTOOG cccccceccecceccscescecceccscescscescscescscuccectsceecscesescescscesesctssscecescesescuceecs 22 CLEANING AND MAINTENANCE ss 23 MAINTENANCE OF THE MOTOR TOP Lose 23 CHANGE OF FILTERS saksere 24 ld Ec 24 PISPOSA ke USE a A PET NM ee 26 TROUBLESHOOTING NS 27 DECLEARAJIIONORCONFORMNIDEY se 28 SERVICE AND REPAIR intei cues vecta ceo eo sex coe tol ove Taxe rev ees aep Oev ve vele oo vade eo or EE ai 29 RONDA 200H RONDA 200H S 4 V BRONDUM A S User Manual RONDA 200H RONDA 200H S 5 V BRONDUM A S User Manual RONDA 200H and 200H S Industrial Vacuum Cleaner for Fine Dust and Dust Hazardous to Health General Description Congratulations on your new RONDA 200H RONDA 200H S industrial vacuum cleaner from V BRONDUM A S AR Read this manual before
2. Pull a plastic bag 100 um or the like over the filter Pull the filter free of the bolt Do not TUG or twist the filter as this may damage the bolt RONDA 200H RONDA 200H S 25 V BRONDUM A S User Manual Close the bag with a cable tie Always dispose of the filter in accordance with the national regulations for the material collected Check the surfaces before the filter is mounted Then mount the filter Mount the washer and the nut Tighten with approx 25nM Disposal of Used Filters When you dispose of the used filters you must make sure that this is done according to the national regulations RONDA 200H RONDA 200H S 26 V BRONDUM A S User Manual Troubleshooting If the machine does not collect the material in a satisfactory way alarm beeps e The suction hose tube or nozzle may be blocked Stop the machine and remove the blocking e collection container or the filter bag may be filled to overflowing Stop the machine and empty the container See the chapter about emptying Aleak might have arisen in connection with the mounting of the motor top Start the machine and block the suction hose Normally you can hear a possible leak Loosen the container clips of the motor top place the motor top correctly and lock the clips again e The filter bag may be blocked If you collect very fine dust the filter bag may block before it is completely full Replace the filter bag
3. be used for the air exhausted WARNING If no hose is used the air exhausted may raise dust from the floor and there may also be a risk of dust exposure The hoses are available in varying lengths It is recommended not to use hoses longer than 10 metres RONDA 200H RONDA 200H S 19 V BRONDUM A S User Manual Cleaning of the Multi Tube Filter during Operation as needed or when the alarm beeps Block the intake hose so that full vacuum is made in the machine Block the intake Pull the flap of the shock valve When the power grows bigger Block the hose while the machine Is blocked than the influence from the and running Do not tug the vacuum the valve will Take hold of the flap of the valve automatically open with a shock valve puff Let go of the valve Repeat the steps 1 3 approx 2 3 times when cleaning The difference in pressure the shock effect will clean the surface of the filter when air is drawn through the valve in order to suppress the negative pressure in the collection container and the hose and will reject possible deposits from the multi tube filter The pressure release valve will close This method gives an effective cleaning of the multi tube filter It is recommended always to leave the machine for a few minutes before emptying it if the machine is being used without filter bag The dust will fall to the bottom of the container and the risk of swirling dust into the surroundings
4. USER MANUAL Original Country code EU CH DK RONDA 200H RONDA 200H S Handy Industrial Vacuum Cleaner for Fine Dust and Dust Hazardous to Health V BRONDUM A S User Manual Table of Contents GENERAL DESC RIP TION SRG 6 SAFETY PRECAUTIONS sa 7 Guidelines in Connection with Disposal of the 8 GENERA SAFETY INSTRUCTIONS saccuivesavonboecaredasdeanthbadeacedinanaieubosnardececs En don Debe stud 9 TECHENC SE DAT NT 11 STANDARD ACCESSORIES fasade 12 APPEICSTIONS sere 13 DESCRIPTION OF THE MAIN PARTS esesesesesesececscsoseseseceseseseseoeoecscceseseseseceseseseoeososcscsesesesesesesesesessosososesesesesesesesesese 14 MOTOR TOP WITH SUCTION MOTOR AND HEPA FILTER 00 c cccccceccecceccscccceccsccscecccceccecescescesescescescescscescescuscecs 14 MOTOR TOP WITH ALARM AND PRESSURE RELIEF VALVE 2ccsccscesceccecceccececcecceccscesceccsccscescesceecscescescesescescesceseucs 14 COLLECTION CONTAINER WITH MULTI TUBE FILTER cccccccscescecceccscescecceccsccscesceccsceecescscescscescescescesescescesenees 15 COLLECTION CONTAINER AND FILTER BAG cccscccecceccecceccccescesccecceccusceccesceecceccescescescesceeccescescescascescesceeseuseeseasceecs 15 MODE OF OPERAT EO kN 16 c
5. e The multi tube filter may be blocked Clean the multi tube filter as described in the chapter about cleaning of filter during operation e The HEPA filter may be blocked Replace the filter as described in the chapter about change of filters If the machine does not start e The fuses of the control circuit may have melted hand tool starts but the machine does not start gt The fuse may have melted The replacement must be made by V BRONDUM A S an authorized V BR NDUM A S dealer or a similarly qualified person in order to avoid hazards RONDA 200H RONDA 200H S 27 V BRONDUM A S User Manual DECLARATION OF CONFORMITY V BR NDUM A S Sadolinsvej 14 16 DK 8600 Silkeborg V BR NDUM A S hereby declares that the following product Electrically operated industrial vacuum cleaner classified for dust class Model RONDA 200H RONDA 200H S has been designed and produced in conformity with the basic requirements and other relevant conditions of the following directives The Machinery Directive Directive 2006 42 EF The compliance has been achieved by use of the following standards EN 60 335 2 69 Verified compliance with standard and directive by SLG Dust class H verified by technical dust test by SLG Silkeborg June 2011 Kennet Raudszus Product amp Quality Manager RONDA 200H RONDA 200H S 28 V BRONDUM A S User Manual Service and R
6. this manual e RONDA 200H RONDA 200H S may be used for collection of dust hazardous to health according to CEI IEC 60335 2 69 Annex AA dust class H e The appliance must be emptied after use e user must ensure that the appliance is adjusted to the task and that regulatory requirements are met e When collecting dust hazardous to health you must use a filter bag and disposal must comply with the legal requirements for material closed container plastic bag etc e Avoid damaging the supply cord When replacing the supply cord only use an original supply cord see the spare parts list V BRONDUM A S an authorized V BR NDUM A S dealer or an equally qualified person must carry out the replacement in order to avoid danger Regularly check the mains connection for damage such as fissures or ageing If damage is found the supply cord must be replaced before further use e The plug must be removed from the power supply before repair and maintenance operations e The mains socket of the machine is to be used only for the purposes specified in the user manual e This machine is intended for commercial use e g in hotels schools hospitals factories shops offices and rental businesses e Before use operators should be provided with information instruction and training for the use of the appliance and the substances for which it is to be used including the safe method of removal and disposal of the material collected e For us
7. which have not been held back by the multi tube filter The filter holds back the particles larger than 0 3 um 0 0003 mm The surface of the filter is 1 1 m and is protected by a metal grating Motor Top with Alarm and Pressure Relief Valve The motor top is equipped with a pressure relief valve and will beep for alarm when the air flow is too low 20 m sec The motor top can be equipped with a separate exhaust coupling l e the air will be exhausted through a hose coupling in the motor top It will then be necessary to use a hose Electrical hand tools can be connected directly to the RONDA 200H RONDA 200H S RONDA 200H RONDA 200H S 14 V BRONDUM A S User Manual Collection Container with Multi Tube Filter The large multi tube filter of the RONDA 200H RONDA 200H S is mounted directly in the collection container The surface of the filter of 8000 cm is coated with Teflon The Teflon coating repels the dust which will in this way not stick so easily to the filter material The multi tube filter has a self cleaning effect during operation The filter consists of a large number of tubes mounted on springs During operation the tubes vibrate a little and a part of the dust sucked on to the surface of the filter will fall down into the collection container Collection Container and Filter Bag The collection container is equipped with 5 swivel wheels The collection container contains the fi
8. and if necessary replace them In this way the life of the suction motor is prolonged If the brushes are not replaced before being completely worn out the motor may seize up and this may require a replacement of the motor Check maintenance of the machine Check replacement ofbrushes 750800 Check of HEPA fiter and machine gt After use as required Check of filters and machine generally Before use Check of cord plugs and outlet for tools Beforeuse Check of alarm beeper Beoeue 1 y o Reordering of filters and service parts 81 73 1768 Multi tube filter 84 67 1111 HEPA filter 84 67 5006 Collection bags 84 64 0033 RONDA 200H RONDA 200H S 23 V BRONDUM A S User Manual Change of Filters In General When replacing the filters the necessary precautions to protect the environment and the respiratory passages of the operator must be taken The nature and scope of these precautions must be based upon the type of dust or sludge being on the surface of the filters Before checking or replacing the filters you must clean the multi tube filter as previously described and you must empty the machine The filters are to be handled in a way not Causing any danger and the safety equipment must be appropriate for the job Check and Replacement of the Multi Tube Filter Item No 84 67 1111 The multi tube filter is made of a robust filter material
9. and the motor top in place A filter bag must be used when collecting dust hazardous to health e Place the collar of the filter bag on the container coupling e Filter bags containing dust hazardous to health must always be closed and disposed of in accordance with the national regulations REMEMBER Always empty the machine after use You must make sure that the dust and material collected cannot fall out of the machine during transport RONDA 200H RONDA 200H S 21 V BRONDUM A S User Manual Reordering of Filter Bags FET Bag NONWOVEN NE 84 64 0033 REMEMBER When the machine has been used without filter bag you must take the necessary precautions against dust exposure Has the machine been used for dust hazardous to health you MUST wear personal protection equipment PPE when emptying and handling the machine Always empty the machine after use Dust hazardous to Health and Asbestos Always check up on the local national regulations in the area where the work is performed Always examine how the disposal is to be packed wrapped up It might be different from place to place Usually the following is mentioned Close fitting packing Drum vat with cover Plastic bag min 100 um Collection of dust hazardous to health must always take place in collection bag The collection bag must be removed from the machine and disposed of in accordance with the national regulations Always mark the materials and waste according t
10. cleaned are to be disposed of Such items shall be disposed of in impervious bags in accordance with any current regulation of the disposal of such waste The upper part of the motor top is a non dust proof compartment and when cleaning the covers of this compartment are removed by loosening the screws fixing the covers IMPORTANT The vacuum cleaner must not be started with covers removed When the automatic start stop is activated in connection with electrical hand tools you must ALWAYS turn off the hand tools before you turn off the machine IMPORTANT The motor top must not be covered when the vacuum cleaner is in use Guidelines in Connection with Disposal of the Machine The product you have purchased is subject to Directive 2002 96 EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment WEEE and should not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposition of this product and otherwise Ge observe all applicable national requirements Does the safe use or maintenance of the appliance raise any questions do not hesitate to contact either your dealer or V BR NDUM A S RONDA 200H RONDA 200H S 8 V BRONDUM A S User Manual General Safety Instructions When using electrical equipment the necessary safety precautions must be taken in order to avoid the risk of fire electrical shock and damage to pe
11. the plug from the socket by pulling the electrical cord Keep the electrical cord away from heating sources oil and sharp edges Choose a safe working position so that there will be no risk of falling in the hose and cord Keep the machine and equipment in good repair Keep the vacuum cleaner clean and dry and follow the instructions of the chapter about RONDA 200H RONDA 200H S 9 V BRONDUM A S 13 14 19 16 User Manual maintenance Cut off the electricity supply when the vacuum cleaner is not in use Remove the plug from the socket before maintenance repair and when the vacuum cleaner is not in use If extension cords are used out of doors they must be approved for this If extension cords are used the following guidelines must be observed Length of cord in metres Up to 20 m 20 50 m show attention and be rested The vacuum cleaner must not be used if the user is tired sleepy or sick or under the influence of alcohol or drugs medicine Check for damage Check the vacuum cleaner for damage Check that the shields etc have been properly fastened Check the electrical switches and have an authorized service mechanic replace them if they are damaged Do not use the vacuum cleaner if it cannot be started and or stopped at the switch RONDA 200H RONDA 200H S is H classified in accordance with the demands of EN 60335 2 69 Annex AA for collection of dust hazardous to health RONDA 200H RON
12. DA 200H S is furthermore in accordance with the Machinery Directive 2006 42 EC WARNING This appliance contains dust hazardous to health Emptying and maintenance operations including removal of the dust collecting means must only be carried out by authorized personnel wearing suitable personal protection Operate only after the full filtration svstem has been fitted and checked 3 labels are enclosed One in Danish one in English and one in French The standard language of the label on the machine is German Therefore the label with the language of the country in question is to be placed on the H label with the text as shown above RONDA 200H RONDA 200H S 10 V BRONDUM A S User Manual Technical Data RONDA 200H RONDA 200H S is connected to 230 V power supply The survey below shows the technical data of RONDA 200H amp RONDA 200H S Voltage Suction motor Power outlet max Vacuum Air volume max Suction power max P2 based on IEC 60312 Filter area multi tube filter Filter area HEPA Collection capacity bag container Height Length Width Weight without accessories Container coupling Length of supply cable Noise Based on ISO 11201 Machine pressure level uncertainty Kpa 3dB Measured only as machine Based on EN 60704 1 2010 and EN60704 2 1 2001 Max Sound Power Level Lwa uncertainty Kwa 3dB Measured with hose pipes and floor accessory Data of the machine
13. and has a very long life However the filter will gradually be worn by the many large and small particles that are held back Therefore it is necessary regularly to check if the filter is undamaged and intact If the filter material is not intact the multi tube filter cannot hold back the dust particles which will penetrate the filter and be caught by the HEPA filter The HEPA filter is intended for very fine dust and will rapidly be blocked if the multi tube filter is damaged e Loosen the container clips of the motor top and remove the motor top e Place the motor top on a dry clean and flat surface e Check the top surface of the multi tube filter for dust particles If you can see dust particles there it is a sign of a damaged and worn multi tube filter A damaged or worn multi tube filter must be replaced A replacement of the multi tube filter should also include a replacement of the HEPA filter Replacement of the HEPA Filter Item No 84 67 5006 e Loosen the four container clips of the motor top and remove the motor top Place the motor top so that the filter is easily accessible In order to ensure a dust free emptying when the HEPA filter is replaced the following procedure must be followed RONDA 200H RONDA 200H S 24 V BRONDUM A S User Manual Remove the nut and washer fastening the HEPA filter Use a size 10 ring spanner BE CAREFUL not to throw away the washer and nut These are to be used again
14. at the user is in no way uncertain as to the use The manual must be stored near the vacuum cleaner Does any uncertainty arise as to the use of the vacuum cleaner or the material collected the work should be stopped until all questions have been cleared Pictures and drawings are for illustrative purpose and will make the understanding of the manual easier The pictures shown may therefore be different from the actual product Safety Precautions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance e The appliance is NOT approved for collection of flammable explosive poisonous or extremely health hazardous dust fluids or gasses DO NOT USE THE VACUUM CLEANER WITHOUT A PROPER GROUND CONNECTION This vacuum cleaner is designed to be used with a grounding connection in an installation with HFI or HPFI The user is responsible for ensuring that the wall outlet is grounded The ground connection of the plug must NOT be removed e RONDA 200H RONDA 200H S must be connected to 230 V power supply Make sure that the voltage and safety fuse of the power supply correspond with the data of the data plate and the information given in
15. during the emptying is reduced NOTE Do not tap on the intake as this will swirl up the dust in the container and result in blocking of the multi tube filter Therefore ALWAYS use the shock valve for cleaning of the multi tube filter during operation RONDA 200H RONDA 200H S 20 V BRONDUM A S User Manual Emptying The RONDA 200H RONDA 200H S can collect the material depending on the character of the material directly the collection container or in a filter bag if collecting dust hazardous to health a filter bag must be used If the machine has been used without filter bag immediately before the emptying it is recommended to wait a few minutes with the emptying to allow the fine dust to fall to the bottom of the collection container e Loosen the four container clips attaching the motor top to the collection container and remove the motor top e Place the motor top on a dry and clean surface e Carefully lift up the multi tube filter in the two handles e Carefully place the multi tube filter on a dry flat surface If no filter bag has been used the collection container can now be emptied e fa filter bag has been used the bag is removed from the container coupling e Close the filter bag e Now you can dispose of the filter bag REMEMBER Disposal of dust hazardous to health must take place in accordance with the national regulations e Puta new filter bag in the collection container e Put the multi tube filter
16. epair service and repair are provided free of charge within the guarantee period invoice must be presented provided that e The defect has been caused by a construction defect or defective materials Normal wear and tear misuse or insufficient maintenance is not covered by the guarantee e No repair attempts have been made by others than V BRONDUM A S or service centres approved by V BR NDUM A S to carry out guarantee repairs service free of charge includes replacement of defect parts and the cost for related working hours The machine is handed in via the V BR NDUM A S dealers or is sent directly carriage paid to V BRONDUM A S Sadolinsvej 14 16 DK 8600 Silkeborg Tlf 45 8682 4366 Fax 45 8680 3363 E mail v broendum com Subject to changes RONDA 200H RONDA 200H S 29 V BRONDUM A S
17. er servicing the appliance must be dismantled cleaned and serviced as far as is reasonably practicable without causing risk to the maintenance staff and others Suitable precautions include RONDA 200H RONDA 200H S 7 V BRONDUM A S User Manual decontamination before dismantling provision for local filtered exhaust ventilation where the appliance is dismantled cleaning of the maintenance area and suitable personal protection In the case of class H appliances the outside of the appliance should be decontaminated by vacuum cleaning methods and wiped clean or treated with sealant before being taken out of a hazardous area All the appliance parts shall be regarded as contaminated when removed from the hazardous area and appropriate action taken to prevent dust dispersal The manufacturer or an instructed person shall perform a technical inspection at least annually consisting of for example inspection of filters for damage air tightness of the appliance and proper function of the control mechanism On class H appliances the appliance filtration efficiency should be tested at least annually or more often according to national requirements The test method that may be used for the verification of the appliance filtration efficiency is given in AA 22 201 2 If the test will not be passed it must be repeated with a new essential filter When carrying out service or repair operations all contaminated items which cannot be satisfactorily
18. lter bag where the material is collected which facilitates the emptying and disposal of the material collected The material can also be collected directly into the collection container Furthermore you can use a filter bag for dust free emptying The filter bag cannot be filled up when very fine dust is collected When collecting dust hazardous to health you must pay attention to the requirements as to disposal of the collected material Closed container plastic bag or container The demands as to packing of the material collected may vary RONDA 200H RONDA 200H S 15 V BRONDUM A S User Manual Mode of Operation When the suction motor of the machine is on the air will be led through the machine and will collect the dust particles near the nozzle mounted The dust particles will be sucked through the hose into the collection container where the majority of the particles will be held back in the filter bag and or the multi tube filter The air flow and the remaining particles which have not fallen to the bottom of the collection container or have been held back in the filter bag or the multi tube filter will be carried forward to the HEPA filter From the HEPA filter the purified air flow will continue through the suction pump blow through and will be led out of the vacuum cleaner through the exhaust and noise reduction filters IMPORTANT As the motor leads the cooling air through the machine all filters MUST be
19. mounted and intact IMPORTANT Never cover up the motor top when the machine is in use IMPORTANT Never collect warm or glowing materials IMPORTANT Never extract from processes producing sparks RONDA 200H RONDA 200H S 16 V BRONDUM A S User Manual Assembling e Check that the packing is intact and has no sign of damage from handling and transport e Unpack RONDA 200H RONDA 200H S and check that all the parts ordered are there e Assemble the three parts of the tube and mount an appropriate nozzle e Fasten the rubber coupling of the suction hose to the tube and mount the other end of the hose in the coupling of the container of RONDA 200H RONDA 200H S e Check that the collection container is empty and that the multi tube filter has been correctly mounted in the collection container Check that the filters of the machine are intact and undamaged see the chapter Change of Filters e If dust hazardous to health is to be collected you must use a collection filter bag e Before the plug is connected to the electrical main supply you must make sure that the plug and the cord are undamaged If the cord or the plug is damaged a professional must replace the parts Only an original cord may be mounted e Connect the machine to 230 V power supply with a reliable earth connection e Remember to place the label onto the H label if the language of the user is not German e RONDA 200H RONDA 200H S is
20. now ready for use The collection is described in details in the following chapter RONDA 200H RONDA 200H S 17 BRONDUM A S User Manual Collection of Dry Dust When the machine has been correctly assembled and connected it can be switched on and off at the red start stop switch of the motor top The machine has been equipped with an alarm indicating when the air flow is too low for collection This alarm has to be checked before use Block the intake at the end of the hose and the machine will start beeping Unblock and the beeper alarm will stop During operation the RONDA 200 can be driven around on the 5 swivel wheels mounted on the collection container The floor nozzle is perfect for collection of dust and materials from large flat surfaces The nozzle is provided with brushes and wheels to ensure an optimal positioning of the nozzle on the flat surface Gradually the brushes will be worn and the nozzle will no longer collect in the optimum way Adjust the height of the wheels using the knob on the nozzle so that the brushes only just touch the floor Electrical Outlet with Automatic Start Stop RONDA 200H RONDA 200H S is equipped with an automatic start stop and electrical outlet If you connect electrical hand tools directly to the power outlet of the motor top the RONDA 200 will automatically be switched on and off when the hand tools are switched on and off Therefore the suction will continue for s
21. o the national regulations If the machine has been used for asbestos the machine must be disassembled and cleaned before it is used in a clean environment The machine must be emptied cleaned and packed before transport Mark the packing according to the national regulations The machine must be transported in a min 120 um plastic bag or other tight fitting packing RONDA 200H RONDA 200H S 22 V BRONDUM A S User Manual Cleaning and Maintenance The machine must always be emptied after use If the machine is left with dust there is a risk of self ignition Read the chapter about safety precautions before cleaning and maintenance The easiest way to clean the machine is as follows e The multi tube filter is cleaned as required e Wipe the machine on the outside with a dry or damp cloth Maintenance of the Motor Top The motor top is made of maintenance free parts and needs therefore no daily maintenance apart from external cleaning and check that the cords and plugs are undamaged The easiest way to clean the motor top is with a damp cloth Do not aim jets of water directly at the motor top In order to avoid stop in operation and also to make sure that the safety of the vacuum cleaner is intact it is recommended that the electrical parts are inspected annually by an authorized technician It is recommended to have an authorized service centre inspect the brushes of the suction motor after approx 800 working hours
22. ome seconds after the hand tools has been switched off before the machine will stop The electrical hand tool is connected to the electrical outlet at the rear of the motor top RONDA 200H RONDA 200H S can be used with hand tools with a power consumption of Country code EU 2000W Country code CH 1200W Information can be found on the data Country code DK 1800W 1800 W corresponds to a current consumption of approx 13A RONDA 200H RONDA 200H S 18 V BRONDUM A S User Manual The automatic start stop is activated with the black switch on the motor top When the automatic start stop is activated the machine will not start when you push the red switch The machine will not start until the hand tool connected is started Set the red switch on I to put on the vacuum cleaner pP Automatic start stop hand tool the automatic start stop is activated The vacuum cleaner will start when you use the Automatic start stop O the automatic start stop is not activated The vacuum cleaner will start when you set the main switch red on P When the automatic start stop is activated 1 and hand tool is connected to the electrical outlet the machine will start when the hand tool is started A ALWAYS TURN OFF the hand tool before you turn off the machine on the switch Separate extraction RONDA 200H S If the machine is equipped with a separate exhaust coupling a hose must
23. rsons The below safety instructions are to be read and followed when the vacuum cleaner is being used Keep the working area clean Slippery and greasy surfaces increase the risk of accidents Be aware of the surroundings Do not expose the vacuum cleaner to rain Do not use the vacuum cleaner in moist or wet surroundings Do not use the vacuum cleaner near flammable gasses or liquids Protect against electrical shock Avoid bodily contact with earthed building parts such as radiator water pipes and the like and also electrical appliances with their own earth connection Keep children and unauthorized persons away from the workplace Do not let unauthorized persons touch the vacuum cleaner or the supply cord All unauthorized persons should be kept at a distance Put the vacuum cleaner away or make it ready for transport after use Keep the vacuum cleaner in a dry place and inaccessible to children Do not use force Do not use force when operating the vacuum cleaner Do not step on the hose or the electrical cord Choose the correct tool accessories for the task Do not use badly proportioned or light tools for heavy tasks Do not use tools for anything they are not intended for Choose suitable working clothes Personal protective equipment Put on eye and or ear protection if necessary Put on respirator in dusty environments Protect the electrical cord Never carry the vacuum cleaner in the electrical cord Do not remove
24. used for collection of fluids or moist dust RONDA 200H RONDA 200H S may not be used for collection of flammable explosive poisonous or other dust fluids or gasses hazardous to health RONDA 200H RONDA 200H S may only be used in dry environments and may not be used or stored outdoors or indoors under wet conditions The capacity of a vacuum cleaner to suck vacuum depends on the air Theoretical the suction capacity will fall when the vacuum cleaner is used at altitudes The suction capacity of the vacuum cleaner will be constant from 0 to approx 800 m above sea level From 800 to 2000 m the suction capacity will theoretically fall to approx 75 It is not recommended to use the vacuum cleaner at more than 2000 m above sea level as the cooling and the suction capacity will be considerably reduced RONDA 200H RONDA 200H S 13 V BRONDUM A S User Manual Description of the Main Parts RONDA 200H RONDA 200H S is designed as a handy and compact industrial vacuum cleaner for collection of fine dust and dust hazardous to health Motor Top with Suction Motor and HEPA Filter The motor top is equipped with suction motor an integrated handle switches for the suction motor and the built in automatic start stop The powerful suction motor of RONDA 200H RONDA 200H S is placed in the motor top The motor top is fitted with a HEPA filter in dust class The filter holds back the fine and smallest dust particles
25. with 4 metres 38 hose In connection with extraction from tools dust extractor it is necessary to ensure a sufficient rate of air renewal L in the room According to the instructions from The Danish Working Environment Service recirculation of extracted air is forbidden RONDA 200H RONDA 200H S 11 V BR NDUM A S User Manual Standard Accessories RONDA 200H RONDA 200H S is delivered with a complete set of accessories including tubes hose and all the necessary nozzles You can reorder the accessories using the following product numbers 1 40 mm professional s Set eere 80 33 4037 2 Plastic hose 4 m 84 54 3809 9 OPSUGE TOZZI ic secsuicesazessecataansiacteanaatasavanteetuansacdteanahtubianeacarananscotien 80 34 4000 ROU DIUS EE NO EE 80 34 4001 5 Floor nozzle 84 38 3620 6 Tubes two straight ones and one curved 80 52 2160 7 Pyramid shaped cuff with hose and coupling 81 56 3810 RONDA 200H RONDA 200H S 12 V BRONDUM A S User Manual Applications RONDA 200H RONDA 200H S is a vacuum cleaner in accordance with DS EN 60335 2 2 and CEI IEC 60335 2 69 Annex AA class H and may only be used as such RONDA 200H RONDA 200H S may be used for collection of dust hazardous to health according to CEI IEC 60335 2 69 Annex AA dust class H RONDA 200H RONDA 200H S may not be
26. you operate the machine Keep the manual readily accessible to all users RONDA 200H RONDA 200H S is an industrial vacuum cleaner developed for the collection of very fine and health hazardous dust RONDA 200H RONDA 200H S meets the requirements for vacuum cleaners within the industry and the construction industry today The machine is ideal for the collection of fine and health hazardous dust such as cement or dust from grinding machines The machine is ideal for use in connection with hand tools self cleaning Teflon coated multi tube filter BIA dust class Filter cleaning during operation with back flush valve HEPA filter BIA IFA dust class Protection level IPX4 IEC 60 529 Satisfies the demands of EN 60 335 2 69 Annex AA for collection of health hazardous dust in dust class H Electrical outlet with automatic start stop Beeper alarm in case of too low air flow Soft start of motor Post suction when using hand tool RONDA 200H S is mounted with separate exhaust coupling It is relatively easy to mount separate exhaust coupling on RONDA 200H if this is required It is however necessary to send the motor top to V Brendum A S or the dealer for alteration The machine cannot immediately be restored to the original RONDA 200H without exhaust coupling RONDA 200H RONDA 200H S 6 V BRONDUM A S User Manual The user manual is to ensure a secure operation of the vacuum cleaner and to secure th