1. 2 variations Pelvis side pads fixed screwed The pelvis side pads are screwed at the pelvis pad and are adjustable in width Pelvis side pads pluggable The pelvis side pads are fixed at the pelvis pad with a pluggable _ system to remove They are also adjustable in width Pelvis retraction strap The pelvis retraction strap is an alternative to the pelvis side pads It is sidewise fixed at the pelvis pad and is individual adjustable The pelvis retraction strap is removable by rack rails and is individual adjustable in width and depth It fixes the pelvis lengthwise Leg pads single or divided foot rest pads can be used as leg pads The single leg pads are straight and rigid and are individual adjustable in height In contrast to thesingle leg pads the divided leg pads are depth adjustable height adjustable and angle adjustable fixed at the central pillars They are individual adjustable by opening the clamp levers 16 Equipment Knee pad As knee pads there are 2 variations possible The standard knee pads are out of foam plastic drawed with fabric Skai and available in 4 different sizes The SHARK knee pads are anatomic applicable and may support and position the knees ideal There are also 4 sizes available The attachment for the knee pads is depth adjustable height adjustable and angle adjustable fixed at the central pillars They are individual adjustable by opening the clamp levers and clamping a
2. amp C SEROLKA user manual Campus PHYSIO t PJ BIGRELAX multifunctional and l practicable Se gt D gt Stand 03 2014 Dear Customer at this point we would like to thank you to have confidence in our products lt s a pleasure for us to sell you a high quality standing system from Berollka aktiv The standing system CAMPUS PHYSIO BIG RELAX is characterized by itsquality safety simplified handling and modern design We kindly ask you to observe the security advice as well as the instructions attentively before using the standing system for the first time We subject to technical changes and improvements of the standing systems Please note that the equipment of your standing system could differ in some allusions and demonstrations EC Declaration of Conformity We Berollka aktiv Rollstuhltechnik GmbH Jahnstra e 16 74889 Sinsheim declare in sole responsibility to conform to the standing systems from Berollka the fundamental request subject to the regulations 93 42 EWG appendix I Yours Berollka aktiv Team Cy BEROLLKA JG bewegt Status March 2014 Technical changes and literal mistakes are reserved Berollka aktiv Rollstuhltechnik GmbH IS Jahnstra e 16 p 74889 Sinsheim reha KIND Germany le ee len telephone 0049 7261 7351 0 ER fax 0049 7261 7351 10 e mail info berollka de website www berollka de All pictures and texts are liable to copy right and it s disallowed
3. foot angle and then you have to close the clamp lever In addition the footplate is individual adjustable in depth and width 18 Equipment Table plate The table plate is out of wood and has got an outline around the table in the ideal case The mount for the intake of the table plate is sidewise fixed at the back pad The mount is angle adjustable with clamp lever and gear segment and consequently it is adjustable in every inclination of the standing system Transport wheels For the mobile use at home the base frame has got wheels with 75 mm diameter and every 4 wheels have got brakes During the therapy the wheels always have to be fixed 19 Equipment Incline adjustment of the standing system The standing system is adjustable from the vertical to the horizontal position and reverse via an electrical adjustment drive linear actuator picture horizontal position The horizontal position is the recumbency position and at once the position which the patient will be put inside by an assistant To this perhaps the side pads which are adjusted to the bedside should be removed Please note The use of the hand control and therefore the incline adjustment of the standing system should be undertaken with caution so that the adjustment is not abrupt the patient gets frightened and clenches Stabilize and support the act of the incline adjustment with your hands Make sure that all screws clamping
4. levers and bolts are tightened 20 Attention Equipment Before the patient can use the standing system the standing system must be regulated with the measure and requirement of the patient It is only possible to do the basic regulations without the patient inside the standing system After that the adjustments must be checked and corrected with the patient inside the standing system Please pay attention that all screws screw nuts and clamp levers are fixed inclinedposition electrical adjustment drive actuator hand control i 9 gt Ag 6 2 AM qg VE 4 gt AK CNA pl h Ya LY ee ee un gt verticalposition Akku rechargeable battery 21 General information to the rechargeable battery First charging It is advisable to charge the battery 12 hours before the first use Due to the fact that you can balance the capacitance loss during the charging if it is necessary Charging temperature The battery should be charged in a surrounding temperature from 0 to 40 degrees Discharging temperature in use The surrounding temperature should be between 15 degrees and 50 degrees during discharging The rechargeable battery is equipped with an acoustic sensor If the keystroke is activated the acoustic charging sensor rings out that the rechargeable battery should be charged Warning lf the handling of the control is possible withal the chargi
5. liability for damage caused by combinations of our standing systems with third party products of any kind that may result in considerable danger may in itself Unless that an express release of such a product exists through our house ATTENTION Because of the permanent use of your standing system it could be possible that some screws become loose Please retighten the screws occasionally or authorize your dealer gt BEROLLKR bewegt Rollstuhltechnik GmbH JahnstraBe 16 74889 Sinsheim Germany Telefon 0049 7261 7351 0 Telefax 0049 7261 7351 10 www berollka de 28 Notes 29 Notes 30 31 SS BEROLLKR bewegt Rollstuhltechnik GmbH JahnstraBe 16 74889 Sinsheim Germany Telefon 0049 7261 7351 0 Telefax 0049 7261 7351 10 www berollka de 32
6. the definitions which you will find by reading the manual A head pad back pad X a i side pads for thorax arm support pads pelvis side pads pelvis pad leg pads knee pads base frame transport wheels footplate with heel shells General Security Advices General Security Advices Because you have to read and consider the manual and general security advices before the first use we Summarized the most important points These security advices have to be considered by patients as well as by companions e Never leave the patient unattended e The companions had to be introduced to safety handling before putting the standing system into service e All screws and pinches must be controlled before each use Please pay special attention to pinch levers along central pillars e Maximum payload Campus PHYSIO BIG RELAX6994 max 100 kg Campus PHYSIO BIG RELAX 6995 max 120kg e According to sickness and patient s weight up to 2 assistants may be necessary to put the patient accurate into the standing system e Adjustments of the standing system should be made according to the sickness Some patients may require a bent position as long as they cannot bear fully upright standing All castorwheelshavetobeblocked e According to disease pattern and therapy the defined duration with the standing system should not be passed e Adjustments on the standing system should always be adapted to disease pattern e Incase o
7. C Declaration of Conformity We Berollka aktiv Rollstuhltechnik GmbH JahnstraBe 16 74889 Sinsheim declare in sole responsibility to conform to the standing systems from Berollka the fundamental request subject to the regulations 93 42 EWG Ce Handling in Delivery Handling in Delivery Your standing system is delivered in a cardboard box Lose items are separately packed with a view to avoiding transport damage Take your expert s help to learn safe using for yourself and your nurse Basic Equipment Your standing system will be delivered serially with the following basic equipment unless there is noother configuration Basic frame with 4 castor wheels several constant leg pillows constant footplate back pad with chest shoulder belt pelvis pad with pelvis side pads head pad incline adjustment with electrical drive from 90 vertical to 0 horizontal battery recharger with power supply pack manual control unit Assembling Please note At least two people are required for assembling so as to avoid injuries After unpacking put the standing desk onto an even and solid ground and please block the transport wheels front side ofthe standing system back side of the standing system Regulation of the standing system Regulation of the standing system The standing system must be adapted to the requirements and measures of the patient before putting him into it It s only possible t
8. d dropped off by opening the clamp lever The arm support pad can be moved and adjusted in width by solving the clamp levers at the upper mount of the back pad Please consider that the mount of the arm support pad is enough conducted at the inside 14 Equipment Side pads for Thorax The side pads are at the right and at the left side ofthe back pad In each case they are forward fixed at the central pillar pipe The side pads conduce to sidewise support of the body They should be set in by patients who have got less control of their body for a sidewise support For this the side pads are independent adjustable in height and width Thereby an ideal asymmetric adjustment can be reached There are 3 different variations Side pad fixed Fixed mount and independent adjustable in height and width Side pad swing away Mount which can swing away till the arm pads Independent adjustable in height and width Side pads pluggable Mount with pluggable system to drop off the side pads Independent adjustable in height and width 15 Zubehor Pelvis pads The pelvis pad is depth adjustable height adjustable and angle adjustablefixed at the central pillars It is independent adjustable by opening the clamp levers It s possible to fix pelvis side pads at the pelvis pad The pelvis side pads are adjustable in width and therefore they can be fit at the backside width As pelvis side pads there are
9. dth of knee pads size of knee pads measurements mm total width Total length Campus max patient PHYSIO BIG RELAX frame table stander vertical stander horizontal weight Berollka aktiv Rollstuhltechnik GmbH Jahnstra e 16 74889 Sinsheim Germany Tel 0049 7261 7351 0 Fax 0049 7261 7351 10 www berollka de Handling Instruction Materials of the standing system In the following table you will find a list of the materials used in their standing device componens maera O BE e Piece 37k Powder coated ne Piece 37k Powder coated Connectors Piece 37K Powder coated and screws 1 4302 chromed una mm IP er mess BE PAS wheels 10 Handling Instruction Handling Instruction Please pay attention as to keep your standing system an even and solid ground If the base frame has got transport wheels they must be locked Attention Please control the connection of all screws bolts and pinches The standing system should be adjusted for the particular patient like on page 8 Regulation of the standing system Entering Please consider that the standing system has to be preset for the requirements and measures of the patient Before entering the pelvis frame must be opened the knee pad must be deviate or must be put away and the table plate also must be put away Entering is only allowed by the help of 2 people and in a vertical inclined position or in a horizontal position of the standing system T
10. e patient he should be supported by another person Open the chest bend and the knee pads so that you can lift the patient out of the standing system lf a patient has no or a little body control the companions must help to enter and to leave 12 Equipment Equipment The standing system is built by a modular construction system so that several equipment can be added subsequent In the following you will find a selection of our variations and equipments which can be lighten the use of your standing system Head pad The head pad is the topmost pad and is mounted at the back pad It is contained in the normal equipment You can regulate and delay the head pad by resolving the clamp lever at the upper mount of the back pad Optional the head pad formed isavailable instead of the standard head pad This head pad is also mounted at the upper mount of the back pad and it s clamped by a clamping bridge The head pad formed is also angle adjustable and depth adjustable It s plugged in the middle ofthe back mount and clamped directly with the clamp lever 13 Equipment Back pad The back pad is fixed with the deepest mount and with the upper mount at the central pillars It can be moved axial By solving the grub screw in the guide pipe of the mounts the back pad can be moved and adjusted Arm support pad The arm support pads are fixed at the right and left side of the back pad They can be extracted an
11. f defect the standing system must remain out of service and has to be repaired by an expert e Disassembling and remounting must be done by skilled experts and at least two of them e Using the standing systems must be restricted to solid even and horizontal ground e Do not use it outdoors e Changing at our construction elements is prohibited and results automatically in loss of warrant Indicationen und therapeutic Use Indication und therapeutic use The standing system allows people with different physical and or psychical limitations the daily necessary upright standing safe without getting tired Everyday standing stabilizes blood circulation prevents bone decalcification osteoporosis corrects contractures of hip and knee joints incites functions of intestines and bladder lungs and kidneys The targeted advancement of head control is optimized by extensive adjustments on all levels Because of its manifold adjustments the CAMPUS PHYSIO RELAX can be used as a standing system as well as a stander for dorsal position The Producer does not take any liability for all other adjustments and the associated damages of any kind Your specialist dealer can give you further information who also shows you the possibilities of variation and adjustments Please note Based on current information no contraindications occurred Indications e paraplegia e multiple sclerosis e muscular dystrophy e infantil cerebral paresis E
12. he patient should lie with the backside at the pelvis pad or should stand with the backside at the height of the pelvis pads and lie with the back at the back pad Following the feet should stand in the heel shells After this the Knees should be positioned in the knee pads Optionally you can fix the feet in the heel shells Attention According to disease pattern the knee pads must be adjusted to the knee After this close the chest belt and or position the side pads The patient takes the standing or dorsal position Now the position of the pelvis pads and of the knee pads must be controlled and re adjusted If you use side pads they should be controlled as well According to sickness and therapy the time tobe passed within the standing system should be respected Remaining to long may cause circulation problems and aching legs or back or even spastic attacks Furthermore there are great differences between patients Some of them cannot be brought into a perfect upright position and may need a bended standing in the beginning For that purpose the pads of the bend contracturemust be adjusted 11 Handling Instruction Leaving Also leaving depends on an even and solid ground of the standing system If it has got transport wheels they must belocked First the side pads should be removed or swing away and in case of using a table it should be removed too After that you can open the foot straps Be careful with th
13. lt Documentation v Name plate Serial Number available v User manual available download is possible at www berollka aktiv de Generally the specialist dealer has to check the condition concerning security and if necessary the appropriate parts have to be replaced 25 Additional Information Warranty In addition to the general terms of business we afford a warranty to the standing system supplied by us 2 years for the base frame and the central pillar for manufacturing defects or defaults in material For the used gas pressure springs and stabilizers we afford you according to the producer information a 12 monthwarrant Defective or damaged parts according to the points stated above will be fixed or replaced within the defects liability period free of charge if Berollka aktiv is informed immediately with the proof of new purchase The rejected parts must be sent free of transportation charges and post free to Berollka aktiv lf a construction fault or a material fault is existent damaged parts will be replaced without charge Changes and constructive interventions which are beyond the adjustment of the personal body height cannot be reasoned by us as the producer Attention Special design versions cannot be exchanged Technical changes are reserved We cannot assume liability for damages because of combinations of our standing systems with external products of any kind which possibly contains a considerable risk U
14. ng Clean the padded parts only with mild soap solution Use only a little moistened cloth for the wood parts lf you want to clean the standing system with a not as much aggressive disinfectant refer to hygienic reasons please operate it only in a spraying and or wipe technique Take a cloth and spray the disinfectant at the cloth and rub the parts with that cloth For the cleaning of our standing systems are all detergents allowed which are licensed for the use of hospital hygiene from the Robert Koch Institute by VAH DGHM Please note It is not allowed to use abrasives or the like strong detergents Don t use high pressure cleaner Note Because of the permanent use of your standing system it could be possible that some screws become loose Please retighten the screws occasionally or authorize your dealer 23 Care Nursing Service and further Use We recommend letting your standing system check from a specialist dealer regularly dependable on the capacity factor however at least one time a year Maintenance First day Read the manual careful before use of the product and keep it for future use Daily replaced or repaired immediately Check the belts chestharness and closures for external signs of wear Pay attention at all maximal information at the adjustments Check that all wheels can spin faultless and that all brakes work faultless Check that the angle adjustment is faultless and that the safety inte
15. ng sensor the rechargeable battery could be destroyed because of deep discharge Charging process To charge the rechargeable battery the cable of the adjustment drive must be pulled out of the rechargeable battery box Following take the cable from the recharger and put it into the cable connector from the rechargeable battery box Now the charging begins It is not possible to do a seat angle adjustment during the charging Please note Because of the decrease of the charge rate during the charging the rechargeable battery is charged to 80 after 4 to 5 hours 22 Care maintenance and further use Care and maintenance The care responsibility of the medical aid or therapy equipment isthe responsibility of the property owner or the owner of the product Non observance of the nursing or the nursing interval referred to the time schedule of the manual of the product causes loss of warrant Furthermore the non observance of the nursing can tends to result in damage of the function or security of the user and or the nurse Your standing system needs regular care Forehanded all metal parts are protected with powder coating eloxal or chromium plating from corrosion Moreover highly stressed parts are made out of stainless steel Please clean your standing system constantly with a soft little moistened cloth or if necessary with a mild detergent without salmiakand dissolver Please dry off the metal partswith a cloth after cleani
16. nless a explicit clearance of such a product exists at our company Furthermore deficits are eliminated which occur because of natural defects excessive use damage by force as well as because of not designated use The warrant expires if no original spare parts from Berollka aktivwill be used for repair Please note Changes at our component parts are not allowed and causes automatically loss of warrant 26 Additional Information Identification Plate The identification plate is located visible at the inside of the cross tube of the base frame bu BEROLLKA Berollka aktiv Typ Campus 6994 6995 Rollstuhltechnik GmbH S N SC94 1 405 Jahnstra e 16 D 74889 Sinsheim Tel 49 0 7261 7351 0 www berollka de Identification plate On the identification plate there you can find the accurate type designation the serial number and the maximal user weight X As Zu 1 N 4 gt y ay a J denn K i f Pa e 2 ual 2 PELE i u Campus PHYSIO BIG RELAX ahnstra e 16 serial number J D 74889 Sinsheim 6995 max Benutzergewicht 120 kg Tel 49 0 7261 7351 0 Serien vre SC94 1009 www berolika de If you want to reorder equipment or spare parts please always specify the serial number and perhaps the order number to guarantee the processing of your order without any difficulty 27 Additional Information Additional Information ATTENTION We can assume no
17. o do the basic adjustments with the measures of the patient without the patient inside the standing system Following the adjustments must be repeated as soon as the patient is standing in the standing system and if necessary it has to be corrected For the particular adjustments you have to adjust the pads with the help of the clamp levers or the provided tools An incline adjustment is possible during the practice Please be careful that all adjustments are locked by putting the screw and the screw nut on Following measurements are needed Measure A Total height measure between upper edge head pad and footplate This measure is equivalent with the body measurements Measure B Chest height measure from chest to footplate Measure C Inside leg measure between seating area and fooiplate Technical changes and printing mistakes are reserved VD231E 03 Technical Information Technical specifications S BEROLLKA Campus PHYSIO BIG RELAX 6994 6995 stander for dorsal position incline adjustable A total height footplate to head pad minimum maximum measure A measure A 4 mom 70cm _ 5 10cm 190cm _ B chest height footplate to chest minimum maximum measure B measure B Campus PHYSIO BIG RELAX 4 90cm 113 em Campus PHYSIO BIG RELAX 5 100 cm 125 cm C inside leg minimum maximum measure C measure C Campus PHYSIO BIG RELAX 4 55 cm 7a em Campus PHYSIO BIG RELAX 5 60 cm 80 cm D wi
18. rlock system works faultless Use a cloth with warm water and a mild detergent to remove dirt and to clean the product Wipetheproductbeforethenextuse Monthly Please check and fix all screws screw nuts and interlocks constantly to guard against unwanted mistakes Oil the movable parts We advice you a professional lubricant for example Metaflux Klarfett Spray Check the frames and the frame parts for abrasion and never use a product with known deficits Please make an inspection at least one time in year at your specialist dealer 24 Further use Further use For the further use of our standing system we recommend an examination of the product by a specialist dealer The following measures must be satisfied e Thorough cleaning and disinfection with appropriate means e Maintenance according to the maintenance plan and review by the manufacturer or authorized specialist Creating the accompanying documents and approval for re use Further use check Optical control v Check the product for cleanliness v Check the surface protection v Check the frame due to damages v Check the cushion and the seat and back cover due to damages Mechanical control v Check all screw and clamp connections and retighten them v Check locking elements to function and completeness v Check the bolting device elements v Check the bowden cables v Check the tyres and air pressure v Check the driver wheels v Check the safety seat be
19. t the central pillar Because of the Four wire connector in front of the attachment the knee pad is individual adjustable to the positioning of the legs It is angle adjustable revolvable and movable mounted The SHARK knee pads are anatomic ideal adjustable because of the constructive creation The knee pad is ideal adjustable by opening the angle of the knee pad It is also depth adjustable height adjustable and angle adjustable Because of the Four wire connector in front of the attachment the SHARK knee pad is individual adjustable to the positioning of the legs It is angle adjustable revolvable and movable mounted 17 Equipment Footplate and heel shells The footplate is constant at the standard equipment and is height adjustable The heel shells can be fixed in different positions at the footrest In addition the feet can be fixed in the heel shells with foot straps Instead of the constant footrest there are also divided footrests available If the patient has got different leg lengths the divided footrests can be set independently of each other Please note The adjustment of the footplate should not be undertaken with the patient in the standing system Additional the footrest is with the option gear segment angle adjustable The footplate is angle adjustable with a ball joint below the footrest Therefore you have to lift the clamp lever below the case After that you have to adjust the
20. to publish without our explicit permission whether in extracts 2 Contents Contents Site e Overview of CAMPUS PHYSIO BIG RELAX 4 e General Security Advices 5 e Indication and therapeutic use 6 e Handling in Delivery 7 e Regulation of the Standing System 8 e echnical Information 9 e Materials 10 e Handling Instruction 11 e Equipment 13 o head pad 13 o back pad 14 o arm support pad 15 o side pad for Thorax 15 o pelvis pad 16 o leg pad 16 o knee pads 17 o footplate and heel shells 18 o table 19 o transport wheels 19 o incline adjustmentof the standing system 20 e General information to the rechargeable battery 22 e Care and maintenance 23 e Further use 25 e Additional Information 26 o Warranty 26 o Identification plate 2 This manual should help you to become acquainted with your standing system Furthermore we want to give you some helpful suggestions how to handle the standing system for daily use in different situations Overview Overview of CAMPUS PHYSIO BIG RELAX The standing system CAMPUS PHYSIO BIG RELAX is used exclusively for standing and recumbent therapy for disabled children and young people In doing so it helps medicate contractures skoliosis and other heavy handicaps Often its successful in absorbing such deformations and in some cases even it s possible to correct them The below mentioned illustration presents the indication of the most important elements at the standing system as well as