1. Z Important Separate electronics of the sliding door lock 13 56 MHz from the other parts and dispose of in NXP Mifare Classic UID NXP Mifare Desfire accordance with local regulations and directives Sony Felica Klartext Mifare Plus SmartMX Inside Secure UID HID iClass UID Infineon SLE66 Warranty conditions This product was designed and manufactured carefully At the moment of purchase the warranty amounts 12 months for material and manufacturing failures The warranty starts with the date of purchase for 12 months The product can be exchanged prior to certification of the proof of pur chase Installation and The warranty conditions are limited to costfree exchange of the product or repair Costs Userman ual and risks caused by transport installation or de installation of the product and all other costs caused by the repairing will not be compensated Liability for consequential loss no matter which type are strictly excluded Congratulations on your purchase of the sliding door lock 13 56 MHz With this decision Obligation of the user you have acquired locking technology with which you can lock and secure furniture without a key but nevertheless in a controlled safe way The user undertakes only to allow persons to work with the sliding door lock 13 56 MHz who The user s manual must be accessible for operators e have been instructed in working with the sliding door lock 13 56 MHz In addition g
2. Technical specifications of the sliding door lock 13 56 MHz Mechanical specification Weight per Set Complete Set 200 Gramm Electrical specifications Equipment class as per Class 2 Directive 1999 5 EC Sliding door lock for 13 56 MHz transponder oF HF radiation output max 66 dBuA m at 10m supported transponders RF standards Frequency band 13 56 MHz 1SO14443A ISO15693 CP atterv vp OR 123A 3V Ambient conditions Operating temperature 5 C bis 35 C 41 F to 95 F C 4 Relative humidity operation 20 bis 75 not condensing ISO 14443 A B bis zu 424 kBit s ISO 15693 RF Sony Felica Inside Secure Disposal A Danger The electronics of the sliding door lock 13 56 MHz contains a lithium ion battery Selected with ISO ee supported supported LEGIC transponders Dispose of this battery in accordance with national regulations transponders e g LEGIC advant ATC CTC LEGIC card in card L sungen AFS LEGIC prime MIM When disposing of partly discharged batteries ensure that no accidental short circuits can occur between the poles of the battery for example due to key fob in pocket of clothing danger of Fasten the partly discharged battery for transport using non conductive adhesive film in such a way that no short circuits can occur Texas Instruments Tag lt Infineon my d Sy NEC Fonim hag ee ele All with ISO 14443 A B Teil 4 bd NXP Ultralight supported transponders e g
3. age resulting from incorrect use the customer bears sole responsibility the manufacturer e 2 pc pins for closing part e e accepts no liability whatsoever e Battery CR123A i Je e Stickers with Logo Conversions or modifications 8 pcs screws Any type of modification to the sliding door lock 13 56 MHz is not permitted e Tool to replace the case The electromagnetic conduct of the sliding door lock 13 56 MHz may be impaired by additions or e Manual modifications of any kind 4 Therefore do not carry out any modifications or additions to electric electronic components Replacement and wear parts and process materials The use of replacement parts from third party manufacturers may lead to dangers Use only original parts or parts approved by the manufacturer Sliding door lock 13 56 MHz installation When unpacking check whether the components as per the description are present Dispose of the packaging in accordance with the applicable regulations of your country Insert battery 1 Normally the battery compartment is already open the cover with screws is contained in an accessory bag Otherwise open the battery compart ment by unscrewing the two M3x6 screws 2 Remove the battery from the blister pack 3 Insert the battery into the battery compartment Observe correct polarity 4 Screw on the battery case cover with the M3x6mm screws provided gt The device is ready for programming Sliding door lock 13 56 MHz general su
4. eneral and local regulations on accident e have read and understood this user s manual Q Important prevention and environmental protection are to be obser ved Warning signals of the sliding door lock 13 56 MHz General safety instructions The lock is equipped with a 3V battery which guarantees up to 20 000 openings The battery level is automatically checked if no opening by radio signal has taken place within 30 days Q Important If the battery level is low or the 20 000 openings have been exceeded the necessary battery replacement is indicated by an audible signal Under certain circumstances the signal may last If the door is closed when starting up or changing the battery without inserting the battery the for several days in which case automatic unlocking of the lock takes place door cannot be opened via radio signals it is necessary to break the door open Follow the exact instructions for installation and start up of the radio systems and replacement of the batteries Remove the flat battery and to prevent a malfunction wait at least 30 seconds Aim of the sliding door lock 13 56 MHz before inserting a new battery Observe correct polarity at the battery case and the battery The sliding door lock 13 56 MHz is a compact wireless furniture lock for cupboards and sliding itself doors It is opened with an electric motor when closed the system locks itself Contactless chip technology is used as the key The sy
5. lso deletes all tranponders of this Group Master card 7 Delete all stored Group Master cards hold the stored Super Master card five times on the card reader panel until a long signal is sounded gt All Group Master cards from this lock are deleted the latch is moved into the open position Note Deleting all Group Master cards also deletes all tranponders of this lock 8 Open the latch e g with Super Master card or Group Master cards and hold the latch in this position Put the Super Master card or one of the Group Master cards 4 times on the card reader panel gt The latch will hold open until a authorised transponder will reset the hold open function Note All saved transponders are stored the latch is moved into the open position EEC Declaration of Conformity in accordance with the directives 2004 108 EC Directive on electro magnetic compatibility EMC 1999 5 EC 1999 Directive on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity R amp TTE 2002 96 EC 2003 Directive on waste electric and electronic equipment WEEE 2011 65 EC Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment recast for the product Sliding door lock 13 56 MHz The following harmonised standards are applied EN 300330 2 V1 3 1 2006 EN 301489 3 V1 4 1 2002 EN ISO 12100 2010 EN 50364 2010
6. rd press the programming button of the lock until a long signal tone starts and immediately afterwards a ticking is audible for approx 10 seconds During the ticking you must hold the Super Master card against the card reader panel until a confirmation tune is audible gt TheSuper Master card is now stored Note When using a new Super Master card the memory will be erased long signal 2 Store Group Master card special card hold the stored Super Master card once against the card reader panel A ticking is audible for approx 10 seconds During the ticking hold the first Group Master card against the card reader panel to read it in until a confirmation a long signal is sounded the ticking continues it will now be another 4 Group Master cards stored If no other more Group Master card is created the ticking ends after about 10 seconds gt The Grooup Master card s is are now stored Note Per lock can max 5 Group Master cards are created 3 Store transponder hold the stored Group Master card once against the card reader panel A ticking is audible for approx 10 seconds During the ticking hold the transponder key fob or card against the card reader panel to read it in until a confirmation a long signal is sounded the ticking continues it will now be another transponder stored If no other more transponder is created the ticking ends after about 10 seconds gt The transponder s is are now stored Note Per Group Ma
7. rvey Screwing holes Programming button Spezial programming connector Card reader panel Install sliding door lock 13 56 MHz on furniture body and door Schiebet r Rolladen Important Assembling distance ca 20 cm pam Q Important RFID Card reader distance LEGIC Key fob up to 15 mm LEGIC card up to 25 mm Check reading distance after assemb ling the sliding door lock 13 56 MHz The lock assembly of furniture and the closing part must always be mounted so that the door in the closed state has at least 0 5 mm di stance This tolerance is necessary for the emergency opening in case of the low battery Make sure that the transponder used have a very good reading quality There should always be a comfortable reading distance be available from the front of the cabinet of at least 5 10 mm The mounting distance between two locks should be approx 20 cm There is otherwise a risk of interference of the fields of the card reading panels That can cause discharge of the battery Program the Latch lock 13 56 MHz On delivery the lock is neutral Programming can be carried out altered at any time as described in the following Standard configuration means wheater the programming card nor the transponder is pro grammed The audible signal is on and the mode standard is activated automatically closing of the latch 1 Store Super Master card special ca
8. stem is woken up and opened by contactless identification via an Important authorised ID medium on the door During installation of the lock and strike plate ensure that the door is not pre stressed and The ID medium is simple to programme or delete The installation of the lock with the springpo stresses are not transferred to the locking system There is a risk that the latch can no longer wered door opener is possible without drilling holes in the piece of furniture open gt malfunction ae Avoid doors which are pre loaded with a rubber profile Functional description Intended use Authorised opening of an electronic lock in wooden furniture with an encoded chip ID medi Authorised opening of an electronic lock in wooden furniture with an encoded chip This chip can um This chip can be in the form of an ID card cheque card format or key fob be in the form of an ID card cheque card format or key fob Function of the lock is only warran ted when mounted on not conductive materials wood plastic The max thickness of the material must not exceed 20 mm If used with higher material thickness or metal doors or doors with metal B N ance a E eee Components of the sliding door lock 13 56 MHz Forseeable misuse The set contains the following components Sliding door lock with changeable case Use of the lock in explosive environments Use of the lock outside of the stipulated specifications a part with break as For dam
9. ster card can max 64 transponders are created max 5 x 64 320 4 Delete stored transponders individually hold the relevant Group Master card two times on the card reader panel A fast ticking is heard for approx 10 seconds During the fast ticking hold the transpon der against the card reader panel to delete it until a confirmation signal is sounded the ticking conti nues it will now be another transponder to delete If no other more transponder is deleted the ticking ends after about 10 seconds gt The transponder s is are deleted 5 Delete all stored transponders from a Group Master card hold the relevant Group Master card five times on the card reader panel until a long signal is sounded gt All transponders from this Group Master card are deleted the latch is moved into the open position Note All other tranponders of other Group Master cards remain stored and function 6 Delete storedGroup Master cards individually hold the stored Super Master card two times on the card reader panel A fast ticking is heard for approx 10 seconds During the fast ticking hold the Group Master card against the card reader panel to delete it until a confirmation signal is sounded the ticking continues it will now be another Group Master card to delete If no other more Group Master card is deleted the ticking ends after about 10 seconds gt The Group Master card s is are deleted Note Deleting the Group Master card a
Download Pdf Manuals
Related Search
Related Contents
Manual de instrucciones HL125G User Manual-Retail AutoRAE 2 Controller Quick Start Guide Samsung Galaxy Music Duos manual do usuário Interlink electronic 7.1 User's Manual ホットカソードゲージ ボックスユニット BMR2 USER`S MANUAL Mantenimiento RUTINAS DE MANTENIMIENTO PREVENTIVO Ednet 87231 drive recorder Lincoln Electric BLUE MAX 308 User's Manual Copyright © All rights reserved.