Home

【User Manual】 DP-102E RS-232 to EDX Interface - Lite

image

Contents

1. SCENE 00 01 FF gt it means the Scene OFF and Scene 1 to Scene 255 in decimal system Channel 01 FF gt it means Channel 1 to Channel 255 in decimal system Channel Data channel dimming level Start Channel start channel address 2 2 Using RS 232 Device to Recall Scene RS 232 device recall a scene in EDX device On the DP 102E control software key in the zone no and scene no on Using PC to recall scene part and click Send button to recall the scene The recall scene command is 11 00 64 01 ZONE SCENE 00 00 00 05 For example RS 232 device to recall the scene 5 of zone 2 in EDX system the command is 11 00 64 01 02 05 00 00 00 05 EDX system in response to RS 232 device After EDX system receive RS 232 device s recall scene command it will send back the command as below 11 00 64 02 ZONE SCENE 00 00 00 05 For example After EDX system receive RS 232 device s command to recall the scene 5 of zone 2 it will sent back the command as below 11 00 64 02 02 05 00 00 00 05 2 3 Using RS 232 Device to Dictate Dimming Level of a Single Channel On the DP 102E control software key in the zone no channel no and dimming level on Dictate dimming level of a single channel part and click Send button to dictate a channel s dimming level The command is 11 00 64 03 ZONE 00 ChannelData 00 05 For example RS 232 device set the channel 5 of zone 3 s dimming level as 20 the command is 3 LITE P
2. Lite Puter iso 9001 CERTIFIED www liteputer com tw DP 102E RS 232 to EDX Interface User Manual LITE PUTER Enterprise Co Ltd Website www liteputer com tw E mail sales liteputer com tw LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw Chapter 1 Introduction De TMU SAAANA NAA AATANI AUNA PARA KERO NUIA 1 2 Specification 1 3 Dimension 1 4 FUN ii ia Wu ree ee Chapter 2 OA Ia nan 2 1 Baud Rate SECHiNg wwwwwmeeeemmmmmmmmmminimimiimmmaaizaziiiii nima zizi 2 2 Using RS 232 Device to Recall SC N eeeeeeeeeecceeeeeeeeeeeeeeneeeeeeeeeeeeeeees 2 3 Using RS 232 Device to Dictate Dimming Level of a Single Channel 2 4 Using RS 232 Device to Check Dimming Level of a Single Channel 2 5 Using RS 232 Device to Increase Decrease All Channel s Dimming Level in a Zone of EDX Device o oo eee eeeeeeeeeecece eee eeeeeeeeeaeeeeeeeeeeeeeeeennaeeees 2 6 Using RS 232 Device to Save EDX Device s Current Dimming Level to LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw Chapter 1 Introduction 1 1 Feature It is an interface that can transform RS 232 signal to EDX signal by which you can transform any equipment s RS 232 signal to standard EDX signal and control the equipment using EDX protocol 1 2 Specification Power Supply DC 12V Signal Input RS 232 DB9 connector the package include one connect wire Signal Output EDX 4pin green te
3. UTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw 11 00 64 03 03 00 05 33 00 05 ii Dimming value 20 255 100 20 51 2 4 Using RS 232 Device to Check Dimming Level of a Single Channel RS 232 device check dimming level of a single channel On the DP 102E control software key in the zone no and channel no on Using PC to check dimming level of a single channel part and click Send button to check the dimming value The command is 11 00 64 04 ZONE 00 Channel 00 00 05 For example RS 232 device check channel 3 of zone 3 s dimming level the command is 11 00 64 04 03 00 05 00 00 05 EDX system in response to RS 232 device After EDX system receive RS 232 device s check dimming level command it will send back the command as below 11 00 64 05 ZONE 00 ChannelData 00 05 For example When channel 5 of zone 3 s dimming level is 35 EDX system will send back the command as below 11 00 64 05 03 00 05 59 00 05 2 5 Using RS 232 Device to Increase Decrease All Channel s Dimming Level in a Zone of EDX Device On the DP 102E control software key in the zone no of EDX device on Increase Decrease part and click Up button to increase all channel s dimming value of this zone at the same time click Down button to decrease all channel s dimming value of this zone at the same time The command is 11 00 64 08 ZONE 0X 00 00 00 05 Notice When the X is 1 it means increase all chan
4. nel s dimming value When the X is 2 it means decrease all channel s dimming value For example Increase all channel s dimming value of zone 1 the command is 4 LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw 11 00 64 08 01 01 00 00 00 05 Decrease all channel s dimming value of zone 8 the command is 11 00 64 08 01 02 00 00 00 05 2 6 Using RS 232 Device to Save EDX Device s Current Dimming Level to a Scene On the DP 102E control software key in the zone no and scene no of EDX device on Save Scene part and click Save button to save EDX device s current dimming value to the scene The command is 11 00 64 09 ZONE SCENE 00 00 00 05 For example There is an EDX 607 EDX device in the system and its zone no is 1 RS 232 device save EDX 607 s channel dimming value to scene 2 the command is 11 00 64 09 01 02 00 00 00 05 5 LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw Guarantee Lite Puter promises to fulfill the following acceptances 1 Lite Puter is only responsible for DP 102E itself 2 Lite Puter guarantees to keep Lite Puter s fault products caused by techniques materials and any other logical reasons in good repair for free within a year since the distributing date 3 We do not offer door visiting service If the trouble appears in Lite Puter s products please deliver the equipment to local distributors or Taipei headq
5. rminal RJ11 2 Dimension 132 W 76 CH 36 2 D mm Weight 0 22Kg 1 3 Dimension T 36 2mm TIa 52m 2 1 LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw 1 4 Function 1e Qe 3e de 5e 1 RJ11 connector for EDX signal 2 4pin green terminal for EDX signal 3 Power input port the device s power can be supplied by EDX signal port or this port DC 12V 4 LED indicator When the device s switch on LED will turn on when the signal transmission is ongoing LED will blink 5 DB 9 connector female for RS 232 signal Chapter 2 Operation 2 1 Baud Rate Setting The DP 102E control software can be downloaded from our website On the DP 102E control software click port and select the port Baud Rate Setting 19200 N 8 2 19200 The Baud Rate is 19200bps 8 To set the data bit as 8 digits 2 To set the stop bit as 2 digits When setting under VB Baud Rate setting command as below MSComm1 Settings 19200 N 8 2 Communication Test Function All the command is in hexadecimal system The command from RS 232 device is 11 00 64 00 00 00 00 00 00 05 if DP 102E sent back 11 00 64 00 80 00 00 00 00 05 it means the device is working well if not it means the connection has problem 2 LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw Notice ZONE 01 FF gt it means the Zone 1 to Zone 255 in decimal system
6. uarter Special Statement Any fault caused by false usage imprudence collision or inadequate installation or force majeure factors are not in Lite Puter s service Revision Record Version Record A First version Issued on November 2009 6 LITE PUTER DP 102E EUM C Lite Puter iso 9001 CERTIFIED www liteputer com tw Lite Puter World Headquarter Lite Puter Enterprise Co Ltd Address 9F No 196 Sec 3 Da Tung Rd Shijr City Taipei Taiwan Zip Code 22103 Tel 886 2 86472828 Fax 886 2 86472727 Website www liteputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai Co Ltd Address Building B5 No 298 Lane 3509 Hongmei S Road Shanghai China Zip Code 201108 Tel 86 21 54408210 Fax 86 21 64978079 Shanghai Sales Center Address Room 701 Building Gem No 487 Tianlin Road Shanghai China Zip Code 201103 Tel 86 21 33674316 33674850 Fax 86 21 33674013 Website www liteputer com cn E mail sales_china liteputer com tw ji LITE PUTER DP 102E EUM C