INSTALLATION AND USER`S MANUAL

image

Contents

1. lower a reset mains turn switch off a choose a better site tleave the room and wait until the delay switch time passes DIMMING OPTIONAL Before you connect the ADR S R turn the mains off Place the dimming module between the connections and the wiring Connect phase L to the brown wire neutral N to the blue wire and the switch wire to 1 10 V Dimmer adjustment The dimmer can be set using the DIP switches on the dimmer module There are 6 dimming levels 100 50 40 35 25 and 15 The DIP positions are shown here and on the dimmer module TECHNICAL SPECIFICATIONS 230 V 10 50 Hz 9Aatcosp 1 3 A at cos 0 4 lt 0 22W lt 4W All round 130 140 5 sec 30 Min motion 0 40 C 25 40 C IP20 54 Minimum 35 lux Maximum 1 000 lux Nominal voltage Maximum continuous power Usage switched on off PIR detection angle Switched off time delay Ambient temperature In deep freeze mode Appliance class Lux values Design subject to alterations veko LIGHTSYSTEMS CE Rev 1 April 2012
2. reflector take the catch off and place the reflector between the catch parts Click the catch in place 3 Installation manual SETTINGS 1 ADR S R gt t The ADR S R has 8 settings for the delayed off switch for motion detection which can be selected using switches 1 to 3 The standard setting is A3 6 min Setting AO has a very short delay only to be used to test the ADR S R and the installation The optional dimmer setting described on page 6 does not affect switching or the lifespan of the bulbs Caution Do not set the delay switch to less than 15 minutes for vapour lamps Short switch times have a negative effect on the lifespan of these lamps because they are not given enough time to warm up If the lighting remains dimmed the switch time can be shorter page 6 Motion detection ADR 9 Installation manual Installation manual EKO LIGHTSYSTEMS PIR sensitivity B The ADR S R has two sensitivity settings for motion detection switch on and continuous The switch on sensitivity setting applies to the first detection lighting is off The continuous sensitivity setting applies after an initial detection and throughout the set delay time The standard setting is BO normal sensitivity Use the less sensitive settings if the lighting comes on unnecessarily or does not switch off properly EKO 1000 lux LIGHTSYSTEMS SETTINGS 2 Switch on setting C
3. INTRODUCTION The ADR S R is a motion sensor system for turning on lights Movement is detected using a pyroelectric infrared sensor PIR The PIR reacts to changes in temperature patterns People and animals radiate heat If they enter or move within the range of the ADR S R motion sensor the heat patterns change within this range The ADR S R detects this and interprets it as motion It remains activated until the source of the heat leaves the area or stops moving The ADR SIR is designed so that it does not immediately switch off when it no longer senses any motion it uses a so called delay switch The motion sensor has a timer which resets each time it detects movement When the timer runs out the lights are switched off The ADR S R is also fitted with a twilight sensor which enables the system not to switch on the lights if the amount of daylight exceeds a certain level This level can be set using a potentio meter INSTALLATION AND USER S MANUAL AD R S R Installation manual LIGHTSYSTEMS Figure B Sensor range height Veko 2012 Schagen Version 1 veko LIGHTSYSTEMS PLACEMENT ADR S Rs are suitable for mounting on lighting rails The standard ADR R detection angle is 130 to 140 The detection angle of the ADR S is restricted in terms of its width This means tha
4. If the ambient temperature is low for example in a cold room there is an option that allows the bulbs to first burn fully for a time C1 The lighting will initially be switched on for 15 minutes and will then be dimmed to between 35 and 100 ADR SD ADR RD Switch on setting D If the light cell does not operate as desired for example because the detector is in an area where there is a lot of light there is an option to deactivate the light cell DO Dipswitch 8 does not have a function T Degree of detection sensitivity Page 4 SETTINGS 3 Twilight switch The ADR S R comes with a twilight switch This ensures that the lighting is not turned on if there is sufficient daylight in the room If this is the case and the daylight level drops below the set value while the room is still occupied the lighting will turn on If the lighting is on and the amount of daylight rises above the set value the lighting will stay on This prevents unnecessary switching on and off Turn clock wise for higher twilight value and counter clockwise for a lower twilight value A higher twilight value means that more daylight is required to stop the lights from turning on ADR 5 R KRIISIN i 23 A Pet SAFETY Before you connect the ADR S R the current must be turned off Only certified electricians are permitted to work on 230V mains All installation instructions must be followed If in doubt cons
5. t the motion sensors will only activate if someone moves into the narrow detection range see Fig B of the sensors that have been mounted in a row The spacing between the sensors depends on the railing height see Fig A Take into account the overlap between the sensors ranges 1m The higher the ceiling the less sensitive the motion sensors will be The ADR S R functions optimally in the centre of the room or passage Caution Ensure that the rail is level both in the length and breadth see Fig B2 Caution The sensitivity of the motion sensor always deteriorates towards the outer edge of its range Page 1 Installati CEILING MOUNTING ADR S R manual CONNECTION Before you connect the ADR S R turn the mains off Standard connection Connect phase L to the brown wire the switch wire NO to the black wire and neutral N to the blue wire When the current is turned on the lighting will always come on The detector s double throw switch is potential free 230 V is connected through a circuit between L and C In its standard setting the NC connection is not used To enable dimming optional a special dimmer switch must be placed between the connection and the wiring This optional setting is described on page 6 Brown Place the lid with the ADR in the rail 1 Turn the catch 90 clockwise 2 If there is a
6. ult VEKO lightsystems technical services department Ensure that the wires are connected according to the colour coding Comply fully with the technical specifications of the equipment Do not use cold start switches if the ADR S R is likely to switch on the lighting more than twice in a 24 hour period The ADR SIR is not certified for use as an alarm system Installation manual Fault Lighting is not switching on Lighting is switching on unnecessarily Lighting is switching off unnecessarily Lighting on permanently Lighting is not switching off when there is sufficient daylight LIGHTSYSTEMS JABBA LA AA EBBA ie A TROUBLESHOOTING Possible cause No current Twilight value not yet reached Bulb defective Switches on after loss of current Sudden change in heat patterns e g printer fan air conditioning etc within detection range No detection within set delay time Person is outside detection range The detector is higher than 12 metres No current Switch is overridden by installation switch Heat patterns within detection range are constantly changing Never switches off with sufficient daylight Solution a check mains adjust settings I replace 1 wait i choose a better site t lower sensitivity 1 choose longer delay i choose a better site a use more detectors 1 set the delay to longer a mount the detector