Product User Manul
Contents
1. AeronebGo Micropump Nebulizer Instruction Manual INTRODUCTION Be sure to read these instructions fully before use Thank you for purchasing the Aeroneb Go Micropump Nebulizer Certain conditions such as asthma COPD chronic obstructive pulmonary disease and cystic fibrosis require that prescribed liquid medication be turned into a fine mist called an aerosol and then inhaled into the lungs The Aeroneb Go turns liquid medication into an aerosol which you can then inhale through a mouthpiece or an aerosol mask into your lungs The Aeroneb Go uses Aerogen s unique OnQ Aerosol Generator which is unlike any other nebulizer technology available When you turn on your nebulizer OnQ pumps liquid through tiny holes in a wafer thin metal plate to create a soft mist aerosol The Aeroneb Go for use by pediatric and adult patients is intended to aerosolize physician prescribed solutions for inhalation that are approved for use with a general purpose nebulizer Designed with your needs in mind the Aeroneb Go is lightweight compact and silent You can power the device with the AC Powered Controller or with the Battery Powered Controller that uses three 3 AA name brand disposable alkaline or lithium batteries CAUTION Federal law restricts this device to sale by or on the order of a physician Operate this unit only as instructed by the Aeroneb Go Instruction Manual Thoroughly read and understand the information containe
2. plugged into a power source Keep this product and cords away from heated surfaces Be sure the device has been properly cleaned before each use to avoid possible contamination Failure to clean device according to instructions may compromise performance or result in the device not working properly Keep power cord tidy so that it cannot become disconnected and no one can trip over it Do not use rechargeable batteries The green light that flashes to indicate a low battery may not turn on properly and the Aeroneb Go may stop working without warning After proper cleaning if it takes longer than 12 minutes to deliver 3mL of medication the Medication Cup with OnO Aerosol Generator should be replaced The user should ensure that exhaled medication is directed away from bystanders CLASSIFICATIONS AND MARKINGS The symbols that appear on the Aeroneb Go Nebulizer and its accessories are described in the table below Symbol Meaning M Attention consult accompanying documents o Class II equipment per IEC 60601 1 Type BF equipment per IEC 60601 1 RA Classified with respect to electric shock fire mechanical and other specified hazards in c UL us accordance with UL 2601 1 and CAN CSA C22 2 No 601 1 Medical Equipment Certified for Canada SN Serial number REF Model Number ll Manufacturer e E Input E Output DC Voltage AC Voltage Power On Off Fragile Han
3. Ill 4 Shake off excess water and allow parts to air dry on a clean dry towel out of the reach of children 5 Make certain that all disinfected parts are completely dry before you store or use them CAUTION Never clean your Nebulizer Unit with vinegar e Never clean your Nebulizer Unit with solvents chemicals alcohol or abrasive cleaners Do not microwave or boil any parts Do not use brushes sharp tools or abrasive cloths that could scratch or damage the surfaces Do not clean parts in a dishwasher Store the assembled Aeroneb Go in the carrying case Do not store the Aeroneb Go in a location where it is exposed to direct sunlight extreme heat or cold dust or water Store out of the reach of children Before storing your Aeroneb Go for a long time remove the batteries from the Battery Powered Controller and store them separately If you do not take the batteries out they may leak and cause your nebulizer to stop working Follow local laws and recycling plans regarding disposal or recycling of components batteries and packaging TROUBLESHOOTING GUIDE If you have difficulty operating your Aeroneb Go check the following points With AC Powered Controller CHECK Check that the AC Powered Controller is plugged correctly into a working outlet REMEDY Insert the plug into a working outlet and verify that the green light on the controller is lit CHECK Check that the AC Powered Controller
4. NOTE Make sure the Aeroneb Go is unplugged before you add medication to the Medication Cup 2 Fill the Medication Cup with the prescribed nebulizer medication Never pour more than 6 mL into the cup The continuous line on the inside surface of the cup indicates the maximum filling level CAUTION To avoid damage to the nebulizer unit do not use a syringe with needle 3 Securely place Cap on Medication Cup 4 Attach Mouthpiece to Nebulizer Body If an optional Mask is used then first attach the Mask Connector Elbow to Nebulizer Body before attaching the Mask NOTE Masks are an optional accessory and may be purchased through your Aeroneb Go Dealer TO OPERATE WITH AC POWERED CONTROLLER 1 Insert the power cord connector into the back of the Nebulizer Unit 2 Plug the AC Powered Controller into a standard AC electrical outlet using the appropriate outlet adapter Visually verify that aerosol is coming out of the mouthpiece or mask to indicate that the device is functioning properly 3 Place the mouthpiece between your teeth with your lips firmly sealed around the mouthpiece If you use an aerosol mask place the mask over your mouth and nose Breathe in and out slowly through your mouth until aerosol formation stops Do not cover the ventilation holes during use 4 Unplug the AC Powered Controller from the wall to turn it off T
5. cord is connected properly to the nebulizer REMEDY Connect the cord properly to the nebulizer With Battery Powered Controller CHECK Check that the batteries are inserted correctly REMEDY Using the markings under each battery location place each battery in the Battery Powered Controller Match and CHECK Check to see if the green light is flashing REMEDY Replace the batteries or use the AC Powered Controller CHECK Check that the Battery Powered Controller cord is connected properly to the nebulizer and to the Battery Powered Controller REMEDY Connect the cord properly to the nebulizer and the Battery Powered Controller With Either Controller CHECK Check that there is medication in the Medication Cup REMEDY Fill the Medication Cup with prescribed medication CHECK Check that the Aeroneb Go has been properly cleaned REMEDY Clean the Aeroneb Go Nebulizer Unit Refer to page 7 If above remedies do not work call your local supplier ELECTROMAGNETIC SUSCEPTIBILITY This device meets the requirements of IEC 60601 1 2 which describes requirements for electromagnetic compatibility EMC of medical devices This includes immunity to radio frequency electric fields and electrostatic discharge in addition to the other applicable requirements of the standard Compliance with EMC standards does not mean a device has total immunity certain devices cellular phones pagers etc can interrupt operation if they are us
6. O OPERATE WITH BATTERY POWERED CONTROLLER 1 Turn the Battery Powered Controller upside down Slide the battery cover in the direction of the arrow to remove the lid Put in three 3 AA name brand disposable alkaline or lithium batteries matching them to the plus and minus markings inside the Battery Powered Controller Replace the cover on the Battery Powered Controller and slide the cover until it locks in place You can expect approximately two 2 hours of operation from name brand batteries and up to six 6 hours with standard not rechargeable lithium batteries 2 Insert the power cord connector into the back of the Nebulizer Unit 3 Connect the power cord to the Battery Powered Controller 4 Turn on the nebulizer by pressing the on off button on the Battery Powered Controller You will see a green light on the Battery Powered Controller light up Visually verify that aerosol is coming out of the mouthpiece or mask to indicate that the device is functioning properly NOTE 1 If you are using batteries and the green light is flashing your batteries are low You may finish your treatment and then replace the three AA batteries immediately 2 If the green light only comes on while depressing the button immediately replace the three AA batteries 5 Place the mouthpiece between your teeth with your lips firmly sealed around the mouthpiece If you use an aerosol mask place the mask ove
7. d in these instructions for future reference SAVE AND REFER TO THESE INSTRUCTIONS IMPORTANT SAFEGUARDS When you use electrical products especially around children always follow basic safety precautions READ ALL INSTRUCTIONS BEFORE YOU USE YOUR NEBULIZER WARNINGS Do not share your Aeroneb Go Nebulizer with others It is intended for use by a single user If more than one person uses it there is a risk of spreading infectious illness Always unplug this product immediately when not in use Adult supervision is required when this product is used by individuals who require special assistance such as children 1 WARNINGS cont Use this product only for inhalation treatments as described in this manual Do not use components or attachments that are not recommended by eVO Medical Solutions Refer to the Accessories section in this manual Never operate this product if any of the parts are not working properly or have been damaged Do not operate the Aeroneb Go Nebulizer in the presence of anesthetic gases which might be flammable when they come in contact with air oxygen or nitrous oxide Do not use the Aeroneb Go Nebulizer with anesthetic breathing systems or lung ventilator breathing systems Do not use this product while you are taking a bath or shower Do not place or store this product where it can fall or be pulled into a tub or sink Do not place or drop this product into water or any liguid when it is
8. dle with Care f T Keep Dry f 7 Storage temperature limits 20 C to 60 C IPXI Drip Proof as per IEC 529 CE This device complies with the requirements of the Medical Devices Directive 0470 93 42 EEC Rx Only Federal law restricts this device to sale by or on the order of a physician PO PANI CAUTION As with any mechanical device this product may become unusable due to an electrical outage battery depletion or mechanical failure We recommend that you have spare batteries and have a backup device available to you If this product is being used to treat a life threatening condition a backup device is necessary IMPORTANT PARTS Medication Cup Cap Ventilation Holes Mouthpiece j Medication Cup c with OnQ Aerosol Generator Nebulizer Body Battery Powered Controller AC Powered Controller with detachable power cord with attached power cord UNIT ASSEMBLY AND USAGE Before you use your Aeroneb Go for the first time after each use or after extended storage clean all parts as described on page 7 ASSEMBLY PRIOR TO ASSEMBLY Check all parts for visible damage Replace any damaged parts before you use the Aeroneb Go Nebulizer In case of missing parts malfunction or damage contact your local Aeroneb Go representative or evo Medical Solutions 1 Connect the Medication Cup containing the OnQ Aerosol Generator to the Nebulizer Body
9. ed near medical equipment SPECIFICATIONS POWER SOURCES AC Powered Controller 100 240 VAC 28 15 mA 50 60 Hz Battery Powered Controller 4 5 VDC 3 AA disposable batteries 350 mA POWER CONSUMPTION Less than 2 watts APPROXIMATE WEIGHT Aeroneb Go Nebulizer Unit 60 g 2 ounces AC Powered Controller 180 g 6 5 ounces Battery Powered Controller with batteries 260 g 9 3 ounces SOUND LEVEL lt 35 dBA at 1 meter APPROXIMATE DIMENSIONS Aeroneb Go Nebulizer Unit assembled 40 0 x 105 0 x 93 0 mm 1 6 x 4 1 x 3 7 inches AC Powered Controller 51 0 x 46 0 x 87 0 mm 2 0 x 1 8 x 3 4 inches Battery Powered Controller 70 0 x 110 0 x 32 0 mm 2 8 x 4 3 x 1 3 inches 10 RECOMMENDED OPERATING ENVIRONMENT Temperature range 5 C to 45 C 41 F to 113 F Atmospheric pressure Greater than 697 mbar Humidity up to 95 relative humidity RECOMMENDED TRANSPORT AND STORAGE ENVIRONMENT Temperature range 20 C to 60 C 4 F to 140 F Atmospheric pressure 450 to 1100 mbar Humidity up to 95 relative humidity PERFORMANCE Aerosol flow rate Greater than 0 3 mL per minute Average particle size 4 6 microns volume median diameter albuterol 3 1 microns mass median aerodynamic diameter Medication Cup capacity Maximum of 6 mL Average pneumatic resistance 60 L min 2 2 cm L sec Rebreathed volume with mouthpiece 46 mL NOTE The temperature of the medication may rise to 10 C 18 F above a
10. er apart to clean it 1 Wash the Nebulizer Unit Medication Cup and Cap Nebulizer Body and Mouthpiece or Mask Connector Elbow and Mask by hand in a solution of warm water and mild liquid dishwashing soap Use only soap intended for washing dishes by hand Do not use dishwasher detergent Do not leave parts soaking 2 Rinse all pieces thoroughly under running hot tap water Make sure that no soap is left on any of the parts 3 Shake off excess water and allow parts to air dry on a clean dry towel out of the reach of children 4 Make certain that all cleaned parts are completely dry before you store or use them WARNING Failure to clean device according to instructions may compromise nebulizer performance or result in device not working properly OPTIONAL DISINFECTION If you would like to disinfect your nebulizer you may use the medical disinfectant described below available from your supplier Use only Control III Laboratory Germicide Maril Products Inc or an eguivalent medical disinfectant to disinfect your nebulizer 1 First clean the Nebulizer Unit as described in the daily cleaning section following steps 1 3 2 Disinfect the Nebulizer Unit parts Medication Cup and Cap Nebulizer Body and Mouthpiece or Mask Connector Elbow and Mask according to the manufacturer s instructions for the medical disinfectant 3 Clean the Nebulizer Unit again as described in the daily cleaning section to remove any residual Control
11. mbient temperature during normal use Performance may vary depending on the type of drug you use and may not apply to drugs not approved for general purpose nebulizers such as suspensions or drugs with high viscosity For additional information contact evo Medical Solutions or your drug supplier REPLACEMENT PARTS AND ACCESSORIES PART REORDER NUMBER Medication Cup Cap 21076 Medication Cup with OnO Aerosol Generator and Cap 21498 Nebulizer Body 21073 Mouthpiece 21074 AC Powered Controller 21099 Battery Powered Controller 21105 Battery Powered Controller Cable 21098 Mask Connector Elbow US 21089 Mask Connector Elbow IN 21090 Carrying Case 21088 Instruction Manual 21495 To order replacement parts or accessories visit your local home medical equipment dealer or pharmacy Contact your local supplier for reorder number specific for your geographical region If you have any questions or problems regarding your Aeroneb Go nebulizer contact your local home medical equipment dealer or pharmacy 11 WARRANTY evo Medical Solutions warrants the Aeroneb Go AC Wall Controller and Battery Powered Controller to be free from defective workmanship and materials for a period of two years from the date of purchase The Nebulizer unit shall be warranted for a period of one year from the date of purchase Check with your dealer for more details This warranty is limited to the original purchaser of the Aeroneb Go Nebulizer Any defec
12. r your mouth and nose Breathe in and out slowly through your mouth until aerosol formation stops Do not cover the ventilation holes during use NOTE 1 The battery controller is designed to shut off after 20 minutes If medication still remains in the cup then simply press the on off button on the Battery Powered Controller to continue with your treatment 2 Battery life is dependent upon not only the number of treatments per day but also the length of each treatment We recommend that you always have a spare set of new unused batteries available to you 6 Press the on off button on the Battery Powered Controller again to turn the A nebulizer off CLEANING AND STORING YOUR AERONEB GO To optimize the performance and life expectancy of your Aeroneb Go device we recommend you follow these cleaning instructions carefully AFTER EVERY USE Disconnect the power source before you take the nebulizer apart to rinse it 1 Rinse the Nebulizer Unit Medication Cup and Cap Nebulizer Body and Mouthpiece or Mask Connector Elbow and Mask under running hot tap water after every use 2 Shake off excess water and allow parts to air dry on a clean dry towel out of the reach of children 3 Make certain that all cleaned parts are completely dry before you store or use them CAUTION Do not use vinegar to clean your nebulizer unit DAILY Disconnect the power source before you take the nebuliz
13. te OnQ Aerosol Generator evo Medical Solutions manufactured by 2636 289th Place Aerogen Inc Adel IA 50003 8021 2071 Stierlin Court Suite 100 USA Mountain View CA 94043 USA www aerogen com 2003 VO Medical Solutions R ONLY P N 21495 Rev 3 05
14. tive part or assembly will be repaired or replaced at the sole discretion and determination of evo Medical Solutions if the unit has not been misused or tampered with during the warranty period Shipping charges if any shall be paid by the purchaser Note There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to the duration of the express limited warranty and to the extent permitted by law and all implied warranties are excluded This warranty does not cover providing a loaner nebulizer compensating for costs incurred for nebulizer rental or labor costs incurred in repairing or replacing defective part s OnQ Aerosol Generator eVO Medical Solutions manufactured by 2636 289th Place Aerogen Inc Adel IA 50003 8021 2071 Stierlin Court Suite 100 USA Mountain View CA 94043 USA www aerogen com 2003 EVO Medical Solutions Ry ONLY P N 21495 Rev 3 05 Featuring Aerogen OnQ micropump trusted technology used in hospitals worldwide For delivery of any nebulizer solution approved for use with a general purpose nebulizer technology that produces liguid aerosol in a manner unlike any other Fast Rapid treatment times Simple Hassle free set up and operation guick cleaning Easy to hold ultra light 2 oz handset Efficient Delivers a high guality respirable aerosol Aerosolizes down to the last drop minimizes medication was