1. v 3 x rated voltage V x rated current A x 10 Single phase 3 wire Full load power kW kvar 2 x rated voltage V x rated current A x 10 Single phase Full load power kW kvar Rated voltage V x rated current A x 10 Multiplying factor Full load power kW kvar Output pulse unit kWh kvarh pulse 1 Applied to only DLC 110 110L Even though multiplying factor is 0 01 multiplying factor display is 0 1 integer digit 4 digits display expansion display 4 digits after decimal point DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 11 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L LC 110 SERIES COMMON SPECIFICATION Approved Standard Pulse Output Intensity Overload capacity Insulation resistance Withstand voltage Strength Lightning impulse withstand voltage Noise capacity Vibration shock 1 Voltage circuit 2 times of rated voltage 10sec 1 2 times continuity 2 Current circuit 40 times of rated current 1sec 20 times 4sec 10 times 16sec 1 2 times continuity 3 Auxiliary power 1 5 times of rated voltage 10 sec 1 2 times continuity 1 5 times of rated voltage at DC100 110 10 sec 1 3 times continuity 4 DC input circuit 4 to 20m A 10 times of rated current 5sec 1 2 times continuity 1 Between electrical system
2. Light of OVERLOAD will ON when leakage current is detection m TA overload is detection CSETD 4 T Scale number This switch is used to select the setting E i Sel automaticaly py measuring mode Display mode will be change to set range seng ting mode when continuously press ON more then 3 sec This switch is used to Upper limit setting index set value in the setting mode Upper limit setting value is indicated When the bar graph is voltage flicker setting value is indicated 0 z E ET G Q This switch is used to confirm overload de tection setting value leakage detection setting value voltage flicker value This Unit display switch also used to carry down set value in setting mode If not operated for 10 sec operated mode will return back to display mode Set automatically by measuremant range setting DISPLAY GO This switch is used for change over the current volt age phase lines After 1 action setting mode dis play will return back to display mode If not operated for 10 min display pattern will return back to setting being completed display pattern This function can be replaced byG switch for setting This switch is used for change main monitor measuring elements Current R gt Current S gt Current T gt Leakage current Voltage RS gt Voltage ST Voltage TR gt measurement change by this order This function can be
3. et 34 easurement display fe BISPLAY ON OFF setting RESET SHIFT and WE and V E DISPLAY Input circuit change setting A RESET SHIFT and 4 RESET SHIFT and Y DISPLAY Return to initial set value RESET SHIFT and RESET SHIFT and DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 10 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L LC 110 SERIES COMMON SPECIFICATION Approved Standard Pulse Output Intensity A Electronic Electronic Electronic Elestionie Electronic Eledirenio Electronic Electronic Electronic multi overload leakage three phase ad three phase DC receiving DC input harmonics demand multi max min meter detection meter voltage meter relay meter multi meter current meter meter meter relay meter QLC 110 HLC 110 DLC 110 MLC 110 LLC 110 ALC 110 VLC 110 XLC 110 TLC 110 ie With backlight QLC 110L HLC 110L DLC 110L MLC 110L LLC 110L ALC 110L VLC 110L XLC 110L TLC 110L Approved standard Output element Pulse Outout output ee pulse constant JIS C 1102 JISC 1102 JISC 1102 JIS C 1102 JIS C 1102 JISC 1102 JISC 1102 JISC 1102 JIS C 1102 1 2 3 4 5 7 1 2 7 1 2 3 5 7 1 2 7 1 2 7 1 2 7 1 2 7 1 2 7 9 1 2 7 8 9 JISC 1111 JIS C 1111 JISC 1111 JISC 1111 JISC 1111 JISC 1111 JIS C 1111 JISC 1111 JISC 1111 JIS C 1216 Performance JI
4. 110L OVERLOAD OPERATION CHARACTERISTICS Overload Operation Characteristic Overload Operation Characteristic Cold Start Characteristics Hot Start Characteristics Ope rated Operated Time Time Ee sec sec TS 30 5 A 105 Multipie of Setting Current Multiple of Setting Current ITEM TO SPECIFY WHEN PURCHASE Specify for product type specification and units require Example of specify Refer to page 1 for specification code Type Specification Code E T T T T T External Operation Input No Backlight Hard Input Input Auxiliary With Backlight Model Circuit Range Power Analog Pulse Alarm Output Output Output 1 Change from initial setting can be accepted with compensation Specify the items to change Refer to page 14 initialization value 2 Have a consultation with us for specification which is not in specification code DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 8 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L NAME AND THE FUNCTION OF EACH PART Bar graph display Digital display Indicate main monitor measurement value 3 elements can be measured and monitored concurrently Measurement value for the sub monitor is Sub monitor L Main monitor Sub monitor R possible by setting Bar graph will display at below the setting digital Light of LEAKAGE will ON when
5. Reset input The max and min reset of the warning output are possible by adding a voltage signal Rating same as the auxiliar power impress smallest pulse width 300ms continuation Input specification Output Specification Analog output 1 circuit 4 20mA 5500 orless 0 1mA 10kO orless Rated value 1 5V 6000 or more 0 5V 6000 or more 0 10V 2kO or more Response time 1 sec orless Time to be within 1 of final constant value Output ripple Less 1 p p against output span Alarm output Output element Overload alarm leakage alarm Output system Non voltage 1a contact AC250V 8A DC125V 0 3A Resistance load Contact capacity AC250V 2A DC125V 0 1A Inductive load Pulse output Output element watt hour Output system Photo MOS FET relay 1a contact Contact capacity AC DC125V 70mA Resistance load Inductive load 250ms 10 In the case of the output pulse cycle atthe ratings electric power becomes the speed of two pulses second or more according to ranges setting the voltage measurement range the current Pulse width measurementrange and output pulse unit range the output pulse width becomes 100 to 130ms Output pulse cycle rated power kW output pulse unit kWh pulse 3600 sec Refer to Page 11 for output pulse unit setting Output ON resistance DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB98 098a 4 ELECTRONIC OVERLOAD LEAKAGE DETECTION
6. ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 2 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L Equipment Specification Input auxiliary power part M4 screw Connecting system Output display change input part M3 screw Main monitor Character height 11mm _ 4 digits LCD Sub monitor L Character height 6mm 4 digits Sub monitor R Character height 6mm 4 digits Bar graph 30 dots Display update time Approx 1 sec Bar graph Approx 0 25sec Three phase current leakage current three phase voltage overload detection Measurement leakage detection Operating tem perature 10 to 55 C hum idity range 30 to 85 RH No condensation Material JABS V 0 Exterior color Black Munsell N1 5 Auxiliary Power Specification AC85 253V 50 60Hz 10VA Power consumption Power consumption No backlight JOYE DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 3 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L Input Specification Voltage circuit rated value 110V FS 150V 0 25VA or less nput power consumption VA Voltage circuit rated value 220V FS 300V 0 5VAorless Current circuit 5A 1A 0 1VAorless Indication reshuffling input Indication reshuffling is possible by adding a voltage signal function same as a DISPLAY switch
7. METER RELAY LLC 110 LLC 110L PERFORMANCE i Allowance 3 Item eel Measuring range Display specification Note ceme Display Output Current AC5 00A 8 00kA 60 range 1 0 R S T phase change 4 Digital against rated sensitivity current value display 0 display when input is 5mA or less RS ST TR line change 5 Leakage max current leakage current z Leakage current ACO 05A 0 8A 5 range 10 Voltage AC150V 600V 5 range 1 0 fF Power integrating only power receiving Only pulse output Ordinary watt hour meter performance conformity Refer to common specification Page 1 for setting range of pulse output unit KWh pulse Power factor 1 2 096 power factor 0 5 2 5 Watt hour Bar graph display Bar graph display of main monitor elements Sub monitor elements can be displayed by setting Main monitor Current leakage current voltage overload characteristics setting value overload operating value setting value sed Sub monitor L Current leakage current leakage max current leakage sensitivity current value setting value voltage oe Sub monitor R Current leakage current leakage operation time setting value voltage Bar graph Current leakage current leakage max current voltage Operation Cold Start characteristics Detection within 2 30sec through 600 current of setting current characteristics Hot start cha
8. PRODUCT CATALOG ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY OUTLINE Most suitable for overload monitor and leakage electric current of the constant voltage circuit Overload current alarm output and leakage alarm output can be extracted FEATURES LLC 110 LLC 110L LLC 110 110L 110 110 105mm 600g Current R S T leakage current voltage RS ST TR can be measured with 1 unit Operating value setting of overload detection is possible Setting for sensibility current value and operation time of leakage detection is possible TYPE AND SPECIFICATION CODE Specification Code AC85 253V DC80 143V l OM I9 TITTTF For both use DC20 56V Note 1 Meter relay with analog output of leakage current can leakage relay B 20m 1 output a contact 2 0 1mA Photo d relay 2 outputa contact 3 Display Change 3 1 5V for xu ud Reset eese 3eaW 3W E E rss zer _ fu pov sa zar DEUM Analog output Except Above a Except Above Except Above Except Above EIUS z Except Above z Except Above be manufactured Alarm output 1 output of leakage only 2 Meter relay with pulse Wh output can be manufactured with following combination Pulse Wh output alarm leakage 1 output external operation input reset Pulse Wh output alarm leakage 1 output DAIICHI
9. SC 1216 Performance JIS C 8325 Performance Performance JISC 1010 1 JISC 1010 1 JIS C 1263 conformed Performance conformed JIS C 8374 conformed conformed Performance Performance Performance conformed EIA standard JIS C 1216 conformed conform ed conformed EIA standard RS 485 Performance Discontinued Model ElAstandard EIA standard EIA standard RS 485 conform ed RS 485 RS 485 RS 485 var hour Output system Photo MOS FET relay 1 a contact Contact capacity AC DC125V 70mA resistance load inductive load Output ON resistance 100 or less Pulse width 250ms 10 There is a case of 100 130ms byrange setting When the output pulse cycle at the rated electric power becomes the speed of 2 pulses or more per second by setting voltage measurement range current measurement range and output pulse unit the output pulse width becomes 100 130ms Output pulse cycle Rated electric power KW output pulse unit kWh pulse 3600 sec For example when voltage measurement range 9000V 6600V 110V current range 80 0A 80A 5A output pulse unit 0 1 kWh pulse rated electric power 1kW x 6600 110V x 80 5A 960 kW output pulse cycle 960 KW 0 1 kWh pulse 3600 sec 2 667 pulse sec pulse width becomes 100 130ms Output pulse unit can be setin following range Output pulse unitis not changed by changing measuring range Three phase 3 wire Three phase 4 wire Full load power kW kvar
10. and case ground DC500V 50MQ or more 2 Between input output and auxiliary power DC500V 50MQ or more 3 Between analog output and pulse output DC500V 50MO or more QLC DLC LLC 4 Between analog output and alarm output DC500V 50MQ or more HLC DLC MLC LLC 5 Between communication output and pulse output DC500V 50MQ or more QLC DLC 6 Between communication output and alarm output DC500V 50MQ or more DLC MLC 7 Between pulse output and alarm output DC500V 50MQ or more DLC LLC 8 Between alarm output 1 and alarm output 2 DC500V 50MQ or more HLC LLC 9 Between DC input 4 to 20mA AC input and auxiliary power DC500V 50MQ or more QLC with DC input 10 Between DC input DC500V 50MQ or more XLC TLC 11 Non insulation bv minus common between analog output QLC DLC HLC XLC TLC MLC 1 Between electrical system and case ground AC2000V 50 60Hz 1min 2 Between input output and auxiliary power AC2000V 50 60 Hz 1 min 3 Between analog output and pulse output AC1500V 50 60Hz 1min QLC DLC LLC 4 Between analog output and alarm output AC1500V 50 60Hz 1min HLC DLC MLC LLC 5 Between communication output and pulse output AC1500V 50 60Hz 1min QLC DLC 6 Between communication output and alarm output AC1500V 50 60Hz 1 min DLC MLC 7 Between pulse output and alarm output AC1500V 50 60Hz 1 min DLC LLC 8 Between alarm output 1 and alarm output 2 AC1500V 50 60Hz 1 min HLC LLC 9 Between DC input 4 to 20m A AC input and
11. auxiliary power AC2000V 50 60Hz 1min QLC with DC input 10 Between DC input AC2000V 50 60Hz 1min XLC TLC 11 Non insulation by minus common between analog output QLC DLC HLC XLC TLC MLC 1 Between electrical system analog output or communication output excluded and ground 6kV 1 2 50us positive negative polarity 3 times for each QLC DLC 2 Between electrical system DC input 4 to 20mA excluded and ground 5kV 1 2 50us positive negative polarity 3 times for each 3 Between analog output or communication output and ground 5kV 1 2 50us positive negative polarity 3 times for each QLC DLC 4 Between auxiliary power and ground 7kV 1 2 50us positive negative polarity 3 times for each LLC 1 Oscillatory surge voltage 1 to 1 5MHz peak voltage When attenuated oscillatory waveform 2 5 to 3kV is applied repeatedly Measured error within 1096 power circuit AC voltage circuit AC current circuit XLC TLC DC voltage current circuit No communication error communication halt 2 Square wave impulse noise Noise 14S 100ns width is repeatedly applied for 5 min Measured erroris within 10 AC voltage AC current circuit normal common 1 5 kVor more Power circuit normal common 1 5 kV or more Pulse output common 1 0 kV or more Alarm output common 1 0 kV or more Operation input common 1 0 kV or more Analog output Inductive 1 0 kV or more Communication output Inductive 1 0kV or more 3 Radio noise When ra
12. dion wave 150 400 900MHz is applied BW 1m intermittently Measured error is within 10 4 Electrostatic noise At the passage of electric current 8kV Measured error within 10 At no passage of electric current 10kV No damage condenser charge system Note There are some cases that some item can not be applied for particular model Refer to type and specification code Vibration 1 2 peak peak 0 15mm 10to55Hz 1 octave min 5times sweep Shock 490m s 3 times for each direction DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 12 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L DISPLAY COMBINATION Pattern 1 Three phase 3 wire Pattern NO Main monitor Sub monitor L Sub monitor R Bar graph 1 Pattern 1 A R Leakage sensitivity Leakage current A R Standard current value A R Leakage current V RS A R Pattern 3 A R A S A T A R RS itivi Specification 4 Pattern 4 Leakage current Leakage sensitivity Leakage operation Leakage max current current value time leakage current wen wmm VS 2 Single phase 3 wire Pattern NO Main monitor Sub monitor L Sub monitor R Bar graph current value A R xm Am A RN itivi i Specification 4 Palin d Leakage current Leakage sensitivity Leakage operation Leakage max current 4 current value time leakage current wm wem VEN Combination beyond above mentioned patt
13. ern can be set by front switch INITIALIZATION VALUE LENT TA No Setting item Single phase 3 wire 110V input 220V input ain monitor fa AR PISPjAw Sub monitor L Leakage sensitivitv current value Leakage sensitivitv current value combination Sub monitor R Leakage current Leakage current Bar graph A R A R B Voltage Upper limit 484V 21V 242V 110 0V s eunen 000A 00A 500A S00N SA 4 Voltage range 600V 440V 110V 300V 220V Direct 150 0V 100 200V Operation value 100 0A secondary 5A 500A secondary 5A detection Resetsystem Autom atic reset Automatic reset Sensitivity current value Leak detection Reset system Autom atic reset Automatic reset DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB98 098a 13
14. gle phase 3 wire R T N 6 When with leakage current analog output Display only and overload detection output is not possible DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 5 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L MEASURING RANGE A Voltage Measuring Range B Current Measuring Range 5 00A v 6 00A 150V 110V FEDA 150 0V 110V 8 00A 300V 220V VT220 110V 10 00A 300 0V 220V VT220 110V 10 0A 600V VT440V 110V 12 00A oes i 12 0A 15 00A 15 0A 20 00A For single phase 3 wire only 150V 150 0V 20 0A Connection Diagram Three phase 3 wire Single phase 3 wire Three phase 3 wire Single phase 3 wire 9 Three phase 3 wire Single phase 3 wire with leakage current analog output with Wh pulse 8 8 AUX SUPPLY BN 7 LEAKAGE CURRENT a ANALOG OUTPUT Ha E iri il Jin PLUSE amr 8 sii OVERLOAD Hi sil LEAKAGE gt 5 Hi alia lue OUTPUT Ba oat l itin Outeur H altar J ALAR output LEAKAGE ALARM OUTPUT DISPLAY CHA INPUT 5 RESET INPUT aX ix 8 RESET INPUT e RESET INPUT H 8 6 Note 6 Wh pulse output leakage current analog output reset input and display change input option 7 In case of single phase 3 wire S phase no 7 becomes N phase 8 In case that leakage current analog output is equipped
15. racteristics Detection within 2 hours through 125 current of setting current Detection within 4 min through 200 current of setting current 2 5A 6A 0 1Astep with function exclusion setting index display setting in primary current a e M de Detection speed change in 5 steps A E Reset system Automatic or manual setting Output contact Non voltage a contact R phase or T phase detection Alarm Test function Trip function test of overload detection is possible in test mode ede Function Leakage current measured value rated sensitivity current value Alarm display output Setting accuracy 50 to 0 against sensitivity current value Rated sensitiviy hos 0 14 0 24 0 4A 0 8A current value Leakage detection Operation time 0 1 sec high speed type 0 3sec 0 5sec 1sec 2sec time delay type function exclusion Reset system Automatic or manual setting Output contact Non voltage a contact Test function Test function check of leakage current detection is possible in test mode Option Resetinput overload detection leakage max current measured value leakage detection display change input leakage current analog output watt hour pulse output Note 3 Due to the measurement system of the meter the accuracy will decrease if the meter directly measures the output of cycle control inverters phase angle control SCR inverters and PWM control inverters 4 Single phase 3 wire RN TN RT 5 Sin
16. replaced by ISPL switch for setting and also can used for carry up a set value in setting mode If not operated for 10 min display mode will return back to settig being completed display pattern Max leakage current and output of overload leakage detection can reset by press ON more than 1 sec continuously This switch also used to shift an item in the setting mode DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 9 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L SETTING Refer to attached user s manual for setting method details SETTING 1 SETTING 2 SET and DISPLAY t SET 3s 3s OY y DI K DISPLAY Display combination setting K DISPLAY 3 Measurement range setting A RESET SHIFT and RESET SHIFT and RESET SHIFT and RESET SHIFT and Y Y Display lt vispLay Voltage flicker value setting K DISPLAY Overload detection setting mode RESET SHIFT and RESET SHIFT and RESET SHIFT and RESET SHIFT and M ec l K DISPLAY DISREAY geet ction change K DISPLAY Leakage detection setting RESET SHIFT and RESET SHIFT and RESET SHIFT and RESET SHIFT and Display lt DISPLAY Display dead band setting mode RESET SHIFT and RESET SHIFT and Refer to page 13 for display combination pattern
17. there is no overload alarm output 9 Do not perform earth ground on secondary ZCT Make wiring from the secondary ZCT to LLC 110 as short as possible In case that ZCT secondary wiring comes near to large current circuit use shielded cable 10 When used in 110V or 220V direct VT is not necessary DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 6 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC 110L Outline Drawing unit mm 7 M4screw EH EHTA l E i Panel cutout Front view ZCT Outline Drawin 50A OMRON OTG LA21 100A OMRON OTG LA30 200A OMRON OTG LA42 Terminal cover 17 13 5 NES 33 5 34 5 600A OMRON OTG LA82 1 9 H l Terminal cover B e p 4 i 1 25nm2VCTFK l e JIS C 3806 da color of line white black ity Terminal cover 17 no polar 33 DAIICHI ELECTRONICS CO LTD http www daiichi ele co jp Digital Measuring Instrument Catalogue e FB 98 098a 7 ELECTRONIC OVERLOAD LEAKAGE DETECTION METER RELAY LLC 110 LLC