Home

User Manual - FF

image

Contents

1. Era TOMATION User Manual v 1 02 DB2SMS Updated 6th Jun 2008 Program description Program sends SMS messages in database to defined phone number in database It also receives SMS messages through GSM modem in serial port www ff automation com DB2SMS VERSION HISTORY cccceecceeececeesseeusseceeseceuseceuseeceeseeeuseseuneeneuseneuseses 3 DB25 EE 3 2 1 NEEDED COMPONENTSETC rnern ratr n rennene annn nn na 3 2 2 INSTALLING DBOGOMS tren rnnenrnnnrnn 3 2 3 CONFIGURING PROGRAM ccccccccsceeeecceeuececeeeeueceeeeuueceeueeueeseueeueeeeueeuseeeneaasaes 4 2 3 1 General configuration description TEE 4 2 3 2 Troubleshooting Modem initialization Groblems 5 RI Kid E 6 3 1 STARTING THE PROGRAM 6 3 2 CLOSING THE PROGRAM 6 3 3 PROGRAM LICENSE sensesnonnennnneeneeionnrnnnrrerren onn r rrin r r AAE rran reAE CE r EnEn naear nn nenen 6 3 3 1 Evaluation period E 6 3 3 2 Purchase and registration cccdessedocnceseoxosrexedsatncthennstandacsuisoorsnnsadesisqeadsrenseends 6 ee 6 RECEIVING MESSAGE 22 cccesccccscecceseccenecceeeeecaeeeeuseceeseeceneeeeuseeeuseeneeeeeeusenusesens 7 4 1 EVENT MESSAGE DECEIvEO EVENT 7 BAT PONMMAb wcsidinotesnniasetiaeustiiubcsiaceiiceds ET E E EEA 7 4 1 2 e 7 4 2 HISTORY RECEIVED HISTORY a sssccscinscstassctnnecdstectaseassasieaadausineantientasecdsads tine 7 BOND E e e ELE 7 E ee E 7 4 3 REPORT RECEIVED _PREPORT c ccccccecccecececccceceeececececesecese
2. e Message receiving date yyyy mm dd Time String e Message receiving time hh mm ss Phone String e Phone number from where the message was received Name String e Sender s name copied from Phonebook_Receiving table Event String e Actual message Tree format ID Integer e Event ID Received_Report Program writes Mindex Integer increasing e Unique identifier for every received message Flag Integer e Value 1 indicates that the message is new The user program e g SCADA can reset this value to zero to indicate that it has read the message Old messages can be deleted e g after reading once per day or week to protect that the table size doesn t increase too much Date String e Message receiving date yyyy mm dd Time String e Message receiving time hh mm ss Phone String e Phone number from where the message was received Name String e Sender s name copied from Phonebook_Receiving table Variable String e Variable s name DB2SMS copies this name from Report_Crosslinks table s name field using the variable number Value String e Variable s value e String type Supports both text and number formats This allows variable s value to be send also in text format Received_History Mindex Integer increasing e Unique identifier for every received message Flag Integer e Value 1 indicates that the message is new The user program e g SCADA can reset
3. by e mail and FF Automation then sends back the right Purchase key to DEE TT activate the license Program informs if e the activation were successful 3 3 3 Moving the license The license can be moved to other PC The original license is removed You should first install DB2SMS to destination PC After that you should add the following line to the original already licensed PC s configuration file Config ini license move Look the previous Config ini parameter explanations table This activates the license transfer state Write the Product key field the destination PC s Product key and click Move Program warns about the license transfer if you answer Yes the original license is removed and you get new Purchase key to be inserted to destination PC s Purchase key field Supervision control and data acquisition system manual 7 Note Be careful when you insert the product key If the product key is faulty the program doesn t generate right purchase key and you will lose the license If this happens please contact with FF Automation Include the product key and the generated purchase key in your message 4 Receiving message Program can receive three types of messages report history data and event messages The program goes through the Phones_Receiving table in the database Only the messages which are coming from the active phone numbers enabled lt gt 0 are accepted 4 1
4. Event message Received_Events Event message can be used to send e g alarm warning status change or any other freely defined message from the GSM PLC Message consists of Message type identifier A Event type nn as integer DateTime DDMMYYHHMMSS and Actual message 4 1 1 Format Ann DDMMYYHHMMSS Message 4 1 2 Examples Receiving event message Problem with date and time ID 0 A0 060705150000 Problem Receiving event message Problem without date and time ID 1 A1 Problem Received events are stored in Received_Events table Look more from database structure chapter 4 2 History Received_History History message can be used to send one variables history e g some sensor s measurement value history History message uses Variable_Crosslinks table Message consists of Message type identifier H variable number nn as integer DateTime DDMMHHYYMMSS Sample Interval HHMM and actual data D1 D2 The data part starts from the most recent value D1 the oldest value comes last 4 2 1 Format Hnn DDMMYYHHMMSS HHMM D1 D2 D3 D4 4 2 2 Examples Receiving history message from variable number 1 Sample interval 1 hour with DateTime H1 060705150000 0100 20 19 19 18 18 19 17 15 14 13 12 12 Receiving history message from variable number 2 Sample interval 3 hour 30 min without DateTime H2 0230 20 19 19 18 18 19 17 15 14 13 12 12 Received history messages are stored in Received_History table The data i
5. field and after that change the flag to 1 which sends the message 5 3 Error messages Server program needs to send e g increasing counter value to PRG_Counter field If the program detects that this value has not changed and the time in A2SMS_Counter has increased to Counter_Max it sends defined message to phone number and put flag to zero When the value in the PRG_Counter field changes it changed flag to 1 6 Error codes 6 1 Log files There are three log files which can be used to debug the possible fault situations etc The logging level is configured in Config ini file File name description Supervision control and data acquisition system manual sms_traffic txt SMS traffic serial_traffic txt Serial traffic state_log txt Program states Error codes 6 2 Error Codes In addition to state_log DB2SMS stores its states also to database Errormessage table Error code Description 0 No errors Modem Errors write to log and database M01x Could not open serial port M02x Message couldn t be send to serial port MO03x Modem is not answering M04x PIN code error wrong PIN SIM locked M05x Could not go to Text mode Mo6y M07x GSM modem signal strenght information sending disabling failed M08x Unknown problem when initialization modem Mix Error in receiving message M2x Error in sending message M3x Error in calculating new messages Critical Errors write to lo
6. PIN or CPIN READY If you get ERROR or CPIN SIM PUK there s a Problem with the SIM AT CMGF 1 text mode ATEO OK sets echo off Supervision control and data acquisition system manual 3 DB2SMS 3 1 Starting the program Program can be started by double clicking the DB2SMS exe file If your program is unlicensed the program informs how much evaluation time you have left and when clicking the Continue Evaluate software button the application is started If the configuration of the program is correct you should see small mobile phone picture in the right down corner system tray B 3 2 Closing the program Program can be closed by double clicking the mouse s right button on the mobile phone picture in the right down corner system tray After that you will get confirmation message and answering Yes closes the program 3 3 Program license 3 3 1 Evaluation period Eei x DB25M5 Evaluation version DB2SMS program can be used 50 hours evaluation time without licensing Program Evaluate software 50 00 left inform how much time is left when it is started Purchase now 3 3 2 Purchase and registration Program can be licensed by selecting the io xi Purchase now checkbox and clicking Continue Program generates product DB2S5MS Evaluation version key which is unique key for PC This key should then be send to FF Automation Product key 247 87 85 244 238 242 e g
7. ame field for e g SCADA application use Not used by DB2SMS Enabled Integer e Watchdog enabled when 1 user defines Flag Integer e Changes to 1 when PRG_Counter and Old_PRG_Counter has different values for too long time e 1 proram ok O problem in program message send PRG_Counter Integer e SCADA should change this using e g increasing counter Old_PRG_Counter Integer e 10 sec intervals the value from PRG_Counter is copied to this A2SMS_Counter Integer Supervision control and data acquisition system manual 12 e Mikali PRG_Counter ja Old_PRG_Counter olivat samoja taman arvo nousee kasvaa yhdella noin 10 sekunnin valein Taman arvo nollataan jos PRG_Counter ja Old_PRG_Counter ovat erisuuria e If PRG Counter and Old_PRG_Counter has same values the value will be increased by one 10 seconds intervals If they differ this value is reset to zero Counter_Max Integer e Max value for A2SMS_Counter before sending the message and flag reset to zero Phone String e Phone number to where the warning message is send Message String e Send warning message Tree format 8 Support Please contact FF Automation by e mail or call if you need additional support www ff automation com Supervision control and data acquisition system manual
8. and it should be defined correctly If you are unsure which value to use you can try one by one which work correctly Look the table next table for more information 6 The connection string defines the database connection MySQL connection string is commented Change the user name and password to correct ones e DB2SMS uses ODBC driver to create connection with database e MySQL Uses MyODBC database connection driver This can be downloaded for example http dev mysql com downloads connector odbc 3 51 html ConnectionString should include Server Database User and Password parameters look example file e PostgreSQL PostgreSQL includes needed ODBC connection drivers You don t need to install these separately ConnectionString should include Server Database User and Password parameters look example file e Access Access 2000 database is not supported If you need to use this you should use Access2SMS program not DB2SMS program Note that DB2SMS program has more features than Access2SMS e Other databases Other databases are not tested with DB2SMS In principle all the databases that uses ODBC interface should work without problems Supervision control and data acquisition system manual 5 7 Normally you don t need to give any other parameters to DB2SMS but in the next table includes all the parameters that can be configured Parameter Mandatoryn Optional Description ConnectionStrin
9. eeseceeseeeeeesesenentass 8 Kr Ge NR Ge e ELE 8 BD ERATION EE 8 SENDING MESSAG Einisiiiiscediicoieci seavcceciicivedeadertiasivencevisasvecaavecasideaatieaasseaoasiuadaveeas 8 5 1 SEND TO GROUP MESSAGE 8 5 2 SEND TO ONE MESSAGES cccccccceceeeeceeeuececseeuueeeeeeeueeeeeeeuseseuuauseusueauseeeueaasess 8 5 3 ERROR MESSAGES cecccececececececececeeeeeeceeececeenecnseceneeaeeeeeeeeeeneeeneeeseeeneeenenenenens 8 ERROR CODES gege cde cecdene cs teed ceeds deve ENEE EE Wade dE EE EN 8 6 1 Beleg IR EEN 8 6 2 ERROR CODES ico te E NE E E EEA EEEE cass 9 DATABASE STUCTURE ccscecssseceeececeeceeusecceseeceeeceeaeeeeueeeeeseeeueeeeeneeeeueeseneseens 9 SUPPOR A EEN 12 Supervision control and data acquisition system manual 1 DB2SMS version history v 1 0 5 1 2007 ArMe Initialization of GSM modem Sending SMS messages to one to group fault events messages Receiving SMS messages report history and event message types Program status in database Compatible with different databases 2 DB2SMS 2 1 Needed components etc Indusoft Web Studio SCADA Or some other SCADA with ODBC support DB2SMS program Win2000 XP OS Microsoft Net Framework 2 0 can be downloaded from Microsoft homepage GSM modem Database which support ODBC interface MySQL PostgreSQL Note Indusoft web studio demo uses PostgreSQL Database connection Please contact FF Automation for more information 2 2 Installing DB2SMS d
10. g x Mandatory Database connection definition Modem_Port x Mandatory Used serial port for GSM modem Modem_Speed Mandatory Serial port speed normally 9600 Modem_Handshaking Mandatory Handshaking level 0 No handshaking 1 XOn XOff 2 Request to send 3 Request to send and XOn XOff pin Xxxx Optional SIM card s PIN code license move Optional Activates licence move state loglevel x Optional default 1 Selects the level for message log 1 Received and send messages are written to log default 2 The serial communication is written to log 3 Both 1 and 2 Config ini Parameter explanations Note If your PIN code request is enabled in your SIM card you should not change the PIN code while the program is running DB2SMS tries to initialize SIM card with the defined PIN code and if the code is wrong the SIM card probably gets locked 2 3 2 Troubleshooting Modem initialization problems If you have problems with initializing modem you can check that these are ok e You have inserted SIM card e PIN code request is disabled you have right PIN code in config ini e You have right type of cable and it is in right COM port e Baudrate is set correctly 9600 If the above were ok you can test that the modem is in TEXT mode and the ECHO is OFF Open HyperTerminal and start session with parameters COM 9600 8 1 N OFF Command Modem should Reply AT OK AT CPIN OK or CPIN SIM
11. g and database if possible info to screen and stops the program Coo Critical program error Unknown error report to FF Automation c02 PIN code insertion error C03 Database not found Errors in message handling write to log only PO DateTime format incorrect P1 Report message format incorrect P2 Message format incorrect P3 Error in saving message 7 Database stucture ErrorMessage Programs writes Errorcode String e Look Error codes chapter Phonebook_Sending User defines Name String e Program doesn t use this field It can be used in SCADA program Phone String e Phone number Enabled Integer e 0 Phone number not in use e 1 Phone number in use Phonebook_Receiving User defines Name String e Program reads the field to Received tables Field can be used also in SCADA program Phone String e Phone number Needs land code e g 3858401234 Enabled e 0 Phone number not in use e 1 Phone number in use Supervision control and data acquisition system manual 10 Received_Events Program writes Mindex Integer increasing e Unique identifier for every received message Flag Integer e Value 1 indicates that the message is new The user program e g SCADA can reset this value to zero to indicate that it has read the message Old messages can be deleted e g after reading once per day or week to protect that the table size doesn t increase too much Date String
12. s divided in separate rows in the table The variable number is changed to variable name using Variable_Crosslinks table Look more from database structure chapter Supervision control and data acquisition system manual 4 3 Report Received_Report Report message can be used to send the latest values of many variables Report message consists of Message type identified D first variable number nn as integer DateTime DDMMHHYYMMSS and actual data Variable values Program uses Variable_Crosslink table to change the variable number to variable name Every variable in the messages data part increases variable s number by one so that first variable s V1 number is nn V2 is nn 1 4 3 1 Format Dnn DDMMYYHHMMSS V1 V2 V3 V3 4 3 2 Examples Receiving Report message from variable values numbers 0 1 and 2 with DateTime DO 060705150000 20 19 21 Receiving Report message from variable values numbers 1 2 and 3 without DateTime D1 20 19 21 5 Sending message Message sending can be done in two ways To one phone number Send to one or to Group of phone numbers Send to group 5 1 Send to Group messages Program sends all messages in the SendAl table which has flag 1 value to phone numbers defined in Phones_Sending table which are active enabled 1 5 2 Send to One messages Program sends all messages in the Send_One table which has flag 1 Before sending the message user should write value to Phone
13. this value to zero to indicate that it has read the message Old messages can be deleted e g after reading once per day or week to protect that the table size doesn t increase too much Supervision control and data acquisition system manual 11 Date String e Message receiving date yyyy mm dd Time String e Message receiving time hh mm ss Phone String e Phone number from where the message was received Name String e Sender s name copied from Phonebook_Receiving table Variable String e Variable s name Read from the message Value String e Variable s value Send_All User defines program changes Mindex Integer increasing e Unique identifier for every send message Flag Integer e Send message Jan This is reset to zero after sending the message Message String e Send message e 160 characters Send_One User defines program changes Mindex Integer increasing e Unique identifier for every send message Flag Integer e Send message Jan This is reset to zero after sending the message Phone String e Phone number Message String e Send message e 160 characters Variable_Crosslinks User defines Index Integer e Variables index number Name String e Variable s name e Note that e g Web Studio SCADA doesn t support special characters or spaces in this field Send_Watchdog User defines partly program changes Name String e Identifier n
14. y 3 Check that you have installed MS Net Framework 2 0 This can be checked form control panel Add remove programs list http www microsoft com downloads details aspx familyid 0856eacb 4362 4b0d 8edd aab15c5e04f5 amp displaylang en Copy DB2SMS program DB2SMS exe and configuration file config ini to your PC e g C DB2SMS directory Installation is ready Supervision control and data acquisition system manual 2 3 Configuring Program 2 3 1 General configuration description When configuring the program you should check the following parameters PIN code The serial port which is used by GSM modem The location of the database DNS name user name and password 1 Open config ini with text editor The file looks like this Modem_Port 2 Modem_PIN 1234 Modem_Speed 9600 Modem_Handshaking 3 ConnectionString DRIVER MySQL ODBC 3 51 Driver SERVER localhost DATABASE smsindusoft USER username PASSWORD passw ConnectionString DRIVER PostgreSQL ANSI SERVER localhost DATABASE smsindusoft USER username PASSWORD passw 2 Used serial port for modem is defined in the first line 3 SIM card s PIN number is defined in the second line You can leave this undefined if the P N code request is configured as off in your SIM card 4 Modem speed is defined in the third line Normally this is 9600 so normally you do not need to change it 5 Modem_Handshaking parameter is important