1. Check and record the result 2 Press to release weighing lock Disabling and enabling the weighing lock function shall be performed only du pressing the HOLD button 1 Press to enable this function 40 2 The LCD shows 00 0 and is ready for input target s S weight 40 3 Input the weight that you wish to deduct ex 10kg 000 Ito finish input 000 5 Now you have 10kg as your deduction 6 did ci and get 60kg as a net weight to return to normal mode 10 to switch on device 40 nofi When it shows zero and beep twice please place a target which you want to tare its weight like clothes on the scale platform to tare the weight of target LCD will return to 00 I zero Then client stands on the scale and weigh The value is the net weight of client The weight of his clothes has been tared at step 3 11 Press 1 2 3 J to switch on device You will need to know the height of the person being weighed so it is best to measure target s height before starting the weighing procedure Proceed to weigh as normal gt ung After the weight is stable ko LCD will then change a display of height 0000 The person being measured now get off the scale as the scale has memorized his her weight BMI press to proceed 14 Enter the height of person with numeric keypad 1860 Exampl
2. apparently abused or improperly maintained f the device exceeds the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the scale specifications All batteries contain toxic compounds disposal of batteries should be delegated to a competent organization complying with the deposit of Poisonous Waste Regulation 1972 Do not incinerate batteries The optimum operating temperature for the scale is 5 to 35 although it will operate at higher and lower temperatures the scale s battery life will be adversely effected We would recommend using alcohol based wipes or similar when cleaning the scales Do not use large amounts of water when cleaning the scales as this will cause damage to the scales electronics You should also refrain from using corrosive liquids or high pressure washers Always disconnect the scales from the electrical power supply before cleaning MAIN TENANCE The scale does not require any routine maintenance However we recommend checking the scales accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the scale If any inaccuracies occur contact your local dealer Before reading detailed instructions on how to use all the weighing functions that are built into your scale please read the following important guidelines Always be sure that the display shows Zero before use if it does not then pl
3. of target during weighing process Ej This enables the operator to select between Metric and Imperial J Clear digits when input wrong digits Press to execute or jump to next step Press to acquire BMI after input user s height gt AUTO OFF TIME SETU This enables operator to setup period to shut off device with no operation automatically gt BUZZER ON OFF SETUP This enables operator to setup ON OFF to the buzzer Auto off time 120 sec 180 sec 240 sec 300 sec off Buzzer On Off OPERATION FLOW KEY DIRECTION GEL UP gt gt 180 5 040 5 300 5 OFF Y bier dud Y I Press mJ to complete setting End OFF Press to complete setting Press for 3 seconds to enter the setting mode Press enter Auto Off menu when you see RUFF symbol Press to select Ub 5 which means Auto Off time is 180s Press to confirm and return to RUF F menu burr menu or RL to select buzzer vu to confirm ON OFF setting to jump to End ang press to save settings Press lto enable weighing lock and em the arrow will start to flash figure1 Proceeding weighing process Device will lock your weight when stable symbol lights up figure2 p ospi q oF
4. KILOTECH MEDICAL SCALES by 5 3900 USER MANUAL Ce manuel est disponible en francais www kilotech com ou aupres de notre service a la clientele au 1 800 694 4445 TABLE OF CONTENTS PREFAOE P 2 INE INFOR MAT m 2 SAFETY INSTRUCTION G duuvusvseeer rer 2 ENVIROMENTAL ce ET ee 3 eI SCH 3 MAINTENANCE nennen nennen nnne nnne 3 DISPOSING OF THE SCALE eese 4 SPE GIF CATON 5 LCD SYMBOL 6 KEY IN IN 7 SETTING UF YOUR DEM STER OR E 8 SETTING UP YOUR DEVICE STEP BY STEP 9 USING YOUR HOLD FUNCTION 10 USING YOUR PRESET TARE 10 USING YOUR SEMI AUTO TARE FUNCTION 11 TOUOSEBVLIFEATUBRE ueneno inet ttis abe iret 12 SCALE ASSEMBLY esee nnne 13 ASSEMBLY INSTRUCTION FOR HEIGHT ROD OPTIONAL 14 INSTRUCTION FOR USING HEIGHT ROD 15 ERROR MESSAGE sssesssesssseseeee eene nnne nnne nnns 16 Than
5. e 186cm the height should be measured by centimeters P 060 Ji again to return to normal mode 12 285 he the jacket through the hole 2 Pull back and press down the indicator to the set 3 Be sure the indicator is stable 4 Screw up the set and indicator On the set 5 Connect the jackets 6 Put the column on the base Note Be sure the set of indicator faces to the correct direction 7 Screw up the column and base 13 on the fixed block Then it s ready for use 14 2 Screwing the Height Rod Press the Pull down the black button plate while button pressed Level the plate to start measuring Note restore plate to the perpendicular while pull di L down through im the indicator x Low battery This warning shows that the voltage of battery is too low to use Please replace new batteries or plug the AC adaptor for operation Counting error too low The loading is lower than limit when power on please increase the loading and try again If the trouble still exists please call your local service partner Overload or counting error too high The loading is over limit when power on please reduce the loading and try again If the trouble still exists please call your local service partner EEPROM Error The program of the scale has error please call your local service partner L f f p 16 Manufactur
6. ease press the ZERO key The Professional Medical scale is designed to detect when a stable weight is achieved the indicator will beep twice to indicate a stable weight value and your reading should be taken at this point Charder medical scales sold by a Kilotech Inc authorized dealer are warranted for 2 years from the original date of purchase and only to the Original end user Kilotech may request a copy of the original invoice prior to making any repair on warranty Charder medical scales sold by a Kilotech Inc are warranted against manufacturer defects under normal use The warranty does not cover the 3 following unsuitable or improper storage installation use or maintenance apparent damage resulting from an accident neglect or abuse or improper handling damage caused by high humidity liquid or foreign substance infiltration damage due to use in temperatures outside the Operating temperature range use near a source of Electro magnetic or RF interference In Canada Charder Medical Scales are repaired by Kilotech Inc at Kilotech s facility in Montreal QC The shipper is responsible to properly pack and return the scale to Kilotech and is responsible for any damage caused to the device because of improper packaging An RMA Return Merchandise Authorization Number must be obtained prior to shipping Customer must adhere to shipping instructions on the RMA The RMA can be obtained by calling 1 800 694 4445 If the cus
7. er s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC FCC CLASS B Declaration of Conformity This device complies with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules IN 0992 7014E 17
8. k you for choosing CHARDER MEDICAL product All features of this product were designed to state of the art and are optimised for simple and Straightforward use If you have any queries or experience any problems not addressed in the operating instructions please contact the dealer from whom you purchased the scale or Kilotech Scales at 800 694 4445 877 328 5988 or www kilotech com We strongly recommend you use the scales on flat and hard surface Any soft surface like carpet will cause inaccuracy Before putting the device into use please read with care the information given in the Operating Instructions They contain important instructions for installation proper use and maintenance of the device The end user must take every precaution to insure the safety of this device and the people using the device Neither Kilotech Inc nor the manufacturer shall be liable for legal issues damages or injuries arising when the scale is used in the following ways or in the following conditions the scale is used in an illegal manner or for an illegal application f the scale is used for any application other than which it was evidently destined f the scale is modified in any way lf the scale is improperly installed f the scale is used outdoors in water high humidity over 80 or temperatures outside of the operating temperatures f used in an improper or illegal electrical installation f the device is
9. tomer is not a Kilotech dealer any payment will need to be secured by Kilotech on a credit card prior to the scale being returned to the customer This product is not to be treated as regular household waste but should be handed in to an electrical electronic equipment recycling center Model Capacity Weight Unit LCD Display Dimension Power Supply Operation Temperature MS 3900 660lb x 0 216 300kg x 0 1kg 1 0 inch LCD display with 5 and 1 2 digits Pole High 800 mm Platform size 340 x 450 mm 6x AAA battery AC adapter 9V 100mA 5 C gt 35 PRE TARE Indication Hold Indication NET WEIGHT Indication BMI Indication WEIGHT Indication Stable symbol When user stands on scale and is stable Minor weight Weight under zero Zero symbol Weight is at zero point Low battery Voltage is too low to operate Stable symbol Minor weight Zero symbol Low Battery chorder POWER PRE BMI HOLD TARE NET WEIGHT kg EIUSSSHHEHEH Description J Press to power on or power off J Press to zero the weight Press to calculate Body Mass Index Press to lock weight value during weighing Remove weight or press key again to disable hold function m ee Press to input weight of subject for example clothes to tare target s weight before standing on scale EJ Press to tare weight
Download Pdf Manuals
Related Search
Related Contents
Samsung LE26A41B User Manual Fujitsu CELVIN NAS QR802 Installation & operating manual PDF ServiceWatch Installation and User Guide Gasoline-Powered Trash Pump MOTOTRBO User Guide - Louisiana Radio Communications Inc. 990-60050-9800 ver 1.0 : DL-24 User`s Manual Thermal Dynamics CutMaster 81 Service Copyright © All rights reserved.