1. protected by the internal fuse Connections for a supply voltage are not provided on the segment terminal The terminal points are only provided for measuring purposes Permissible Total Current in the Potential Jumpers of the Main and Segment Circuit Nominal Current of the Terminal Permissible total current in the potential jumpers Nominal current of the terminal Tolerance I Power Dissipation Formula to Calculate the Power Dissipation of the Electronics 500 kbps Pror 0 180 W I1 x R The terminal is supplied with a 6 3 A slow blow fuse Where Por Total power dissipation in the terminal I Load current in the segment circuit Re Resistance of the fuse The resistance of the fuse Rp for a 6 3 AT fuse is approximately 12 mQ The power dissipation of the electronics for a theoretical maximum current of 6 3 A nominal current 4 0 A is calculated as follows Prot 0 18 W 39 69 A x 0 012 Q 0 66 W 500 kbps 2 Mbps 6 3A 5AA 4 0A 4 0A 10 10 Formula to Calculate the Power Dissipation of the Electronics 2 Mbps Pro 0 34 W IL x R Where Por Total power dissipation in the terminal lL Load current in the segment circuit Re Resistance of the fuse The resistance of the fuse Rp for a 6 3 AT fuse is approximately 12 mQ The power dissipation of the electronics for a theoretical maximum current of 5 4 A nominal current 4 0 A is calculated as follows Prot 0 34 W 29 16 A x 0 012 Q
2. or via the bus coupler and a power terminal from separate power supply units Interconnection of the power supply units in the 24 V area is not permitted Please also observe the GND PE connections on the power supply units see also user manual Common Potentials The 24 V main voltage 24 V segment voltage and GND have the same potential FE is a separate potential area Separate Potentials in the System Consisting of Bus Coupler Power Terminal and I O Terminal Test Distance Test Voltage 5 V supply incoming remote bus 7 5 V supply bus logic 5 V supply outgoing remote bus 7 5 V supply bus logic 7 5 V supply bus logic 24 V supply I O 24 V supply I O functional earth ground 500 V AC 50 Hz 1 min 500 V AC 50 Hz 1 min 500 V AC 50 Hz 1 min 500 V AC 50 Hz 1 min Error Messages to the Higher Level Control or Computer System I O error message if fuse has blown or is missing I O error message if supply voltage Uj is not present Approvals For the latest approvals please visit www download phoenixcontact com 5658 _en_03 PHOENIX CONTACT 4 IB IL 24 SEGIF D Local Diagnostic and Status Indicators Local Diagnostic Indicators and Terminal Point Assignment Des Color Meaning SS Green Diagnostics Flashing 0 5 Hz Communications power present Bus not active Communications power present supply voltage Un not present or fuse has blown Communications power present local bu
3. 0 68 W Power Dissipation of the Housing Phou 500 kbps and 2 Mbps Phou 9 7 W in the total permissible ambient temperature range 5658 _en_03 PHOENIX CONTACT 3 IB IL 24 SEGIF D Typical Power Dissipation of the Electronics Depending on the Load Current in the Segment Circuit 500 kbps 2 Mbps 1 2 1 0 1 1 0 9 1 0 0 8 0 9 0 7 oe 0 6 0 7 0 5 hee S 4 o5 a 204 0 3 a 0 3 0 2 0 2 0 1 0 1 0 0 0 1 0 5 1 2 4 6 8 0 1 0 5 1 2 4 6 8 I A 5569C006 I A 6772A006 P W Power dissipation in W IL A Load current in the segment circuit in A P W Power dissipation in W IL A Load current in the segment circuit in A This test was carried out with a 6 3 AT fuse This test was carried out with a 6 3 AT fuse Derating of the Load Current in the Segment Circuit No derating Safeguards Overload short circuit in the segment circuit Fuse 5 x 20 with 6 3 A slow blow IEJ Fuses with other values can also be used The maximum fuse value must not exceed 6 3 A Note for the selection of fuses For fuses with a value greater than 2 A only slow blow fuses may be used Surge voltage Protective elements in the power terminal or the bus coupler Protection against polarity reversal Protective elements in the power terminal or the bus coupler Electrical lsolation Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I O area it is necessary to supply these areas via the bus coupler
4. 7462 10 IB IL SCN PWR IN CP 2727637 10 SI 5 x20 6 300 A T 5030512 10 Type Order No Pcs Pkt IB IL SYS PRO UME 2743048 1 IL SYS INST UME 2698737 1 12 2 mm x 120 mm x 71 5 mm 44 g approximately without connector 59 g approximately with connector Process data mode with 2 bits 25 C to 55 C 25 C to 85 C 10 to 95 according to DIN EN 61131 2 70 kPa to 106 kPa up to 3000 m above sea level IP20 according to IEC 60529 Class 3 according to VDE 0106 IEC 60536 Spring cage terminals 0 2 mm to 1 5 mm solid or stranded 24 16 AWG Through data routing PHOENIX CONTACT 2 Transmission Speed IB IL 24 SEG F D IB IL 24 SEG F D PAC IB IL 24 SEG F D 2MBD IB IL 24 SEG F D 2MBD PAC Power Consumption Communications power UL Current consumption at UL Power consumption at UL Main voltage Um Nominal current consumption at Um IB IL 24 SEGI F D 500 kbps 500 kbps 2 Mbps 2 Mbps 500 kbps 7 5V DC 25 mA maximum 2 Mbps 7 5 VDC 45 mA maximum 0 34 W maximum 24 V DC nominal value 4 0 A nominal value 0 19 W maximum 24 V DC nominal value 4 0 A nominal value Supply of the Module Electronics and the I O Through the Bus Coupler Power Terminal UL Uy Connection method 24 V I O Supply Uy Us Through potential routing The main voltage Uy is supplied at the bus coupler or at a power terminal The segment voltage Us is provided automatically at this segment terminal and
5. IB IL 24 SEG F D Inline Segment Terminal With Fuse and Diagnostics ap 50 Gb AUTOMATIONWORX EG g Data Sheet 5 9658 en 03 PHOENIX CONTACT 01 2007 Description Features The terminal is designed for use within an Inline station a creation of a segment circuit within the main The segment terminal is used to create a protected partial Segment circuit protected by an internal fuse circuit Segment circuit within the main circuit Diagnostic indicators The terminal is not used to supply power and has no Mapping of the status of the internal fuse and the main elements for protection against polarity reversal and surge voltage to the input data voltage This terminal has an LED for diagnostics and occupies two input data bits which are used to indicate the presence of the supply voltage and the state of the fuse This data sheet is only valid in association with the IB IL SYS PRO UM E user manual or the Inline system manual for your bus system Make sure you always use the latest documentation It can be downloaded at www download phoenixcontact com A conversion table is available on the Internet at www download phoenixcontact com general 7000 en OO pdf IR This data sheet is valid for all products listed on the following page DOGO M000 Weonnc ODE INSPIRING INNOVATIONS Ordering Data Products Description Inline Segment terminal with fuse and diagnostics without accessories transmission spe
6. NTERBUS BE 90a Process data channel 2 bits Output address area 0 bits Parameter channel PCP Other Bus Systems For the programming data configuration data of other bus systems please refer to the corresponding electronic device data sheet e g GSD EDS Process Data Assignment of IN Process Data S the fuse and the main voltage Byte bit view 0 1 0 0 Assignment Main voltage Up present 1 1 k fsevownsrmiong o fuse blown or missing Main voltage Uy not present olo For the assignment of the illustrated byte bit view to your INTERBUS control or computer system please refer to the DB GB IBS SYS ADDRESS data sheet Order No 9000990 PHOENIX CONTACT 01 2007 5658 en 03 PHOENIX CONTACT GmbH amp Co KG 32823 Blomberg Germany 6 Phone 49 0 5235 3 00 Fax 49 0 5235 3 4 12 00 www phoenixcontact com
7. ed of 500 kbps Inline Segment terminal with fuse and diagnostics complete with accessories connector and labeling field transmission speed of 500 kbps Inline Segment terminal with fuse and diagnostics without accessories transmission speed of 2 Mbps Inline Segment terminal with fuse and diagnostics complete with accessories connector and labeling field transmission speed of 2 Mbps EJ Accessories Description Connector black w o color print Connector black with color print Fuse Documentation Description Configuring and Installing the INTERBUS Inline Product Range user manual Automation Terminals of the Inline Product Range user manual Technical Data General Data Housing dimensions width x height x depth Weight Operating mode Ambient temperature operation Ambient temperature storage transport Permissible humidity operation storage transport Air pressure operation storage transport Degree of protection Protection class Connection data for Inline connector Connection method Conductor cross section Interface Local bus 5658_en_03 IB IL 24 SEG F D Type Order No Pcs Pck IB IL 24 SEG F D 2836683 1 IB IL 24 SEG F D PAC 2861904 1 IB IL 24 SEG F D 2MBD 2855033 1 IB IL 24 SEG F D 2MBD PAC 2861946 1 One of the connectors listed below is needed for the complete fitting of the IB IL 24 SEG F D and IB IL 24 SEG F D 2MBD terminals Type Order No Pcs Pkt IB IL SCN PWR IN 272
8. s error Communications power not present Bus not active Red OFF ON Fuse in segment circuit Us Fuse has blown is generated on the higher level control or computer system 5658B003 A blown or missing fuse is indicated by both diagnostic indicators The red E LED lights up and the green D LED flashes at 2 Hz IR If supply voltage Uy is not present and the fuse has blown or is missing an I O error message Figure 1 Terminal with appropriate connector IR Function Identification Black 2 Mbps white stripe in the vicinity of the LED D Terminal Point Assignment Terminal Point Segment voltage Us after the fuse 1 2 2 2 Main voltage Un voltage Main voltage Un ists nai GND of the supply voltages Functional earth ground FE The terminal points are only provided for measuring purposes 5658_en_03 PHOENIX CONTACT 5 IB IL 24 SEGIF D Internal Circuit Diagram Local bus 24 V U 24 V Up 24 V U A A 7383A004 Figure 2 Internal wiring of the terminal points Protocol chip bus logic including voltage conditioning LED with details of the indicator designation D or E See page 5 Key ec Optocoupler ea Fuse l T Capacitive connection to functional earth ground FE Electrically isolated area Other symbols used are explained in the IB IL SYS PRO UM E user manual or the system manual for your bus system Programming Data Local Bus I