1. of communication cable into angle meter that does not support communication function Connecting communication cable Turn off power and then connect the accessory cable between the COM port of PC and meter _ ye th Vr AA es Uploading record data Make sure the connection between PC and meter is normal Visit the communication menu Coa shows Press A or Y to start communication function SEnd will be shown Use PC to start the uploader program In uploader program first select the correct COM port No Finally press upload button to transmit the records to PC The uploaded data is then shown on the column and saved in the csv file Use Microsoft Excel to view csv file Caution Refer to the uploader program user guide for the detail operations Next select the file path to save the uploaded data MAINTENANCE AND STORAGE Attention One year periodic recalibration is necessary to maintain accuracy Please contact your local dealer for calibra tions Caution 1 Do not shake violently or drop meter 2 Do not leave this meter in any place exposed to excessive heat humidity or direct sunlight 3 Do not use this apparatus in water it is not waterproof 4 If the meter gets wet wipe it with a dry towel as soon as possible The salt in seawater can be especially damaging 5 Do not use organic solvents such as alcohol or paint thinner when cleaning the m
2. 0 CE am gt over 99 5 7 Clear angle value Calculating angle again or Save angle record Pressing will clear the current angle 383 e00 77 Flashing N Press C Current target angle Pressing S S will calcualte angle again from current angle N 3 03 S Flashing N Press S S Start to count angle from 30 3 Pressing M will record the current value and then clear the current value n r ni 303 l nu ie 7 flashing N Press M Show record and data number SETUP MENU INTRODUCTION From the current target angle screen long press to go into setup menu Continuously press can visit the direction menu record menu record clear all menu and communication menu Finally press again to skip out the setup menu and go back to the current target angle screen nn U gt PoS Long press S S or r nEL Direction menu Press S S nn n nut 303 Record menu Press S S m CLA Record clear all menu Press S S Current target angle Press S S r 0 LON Communication menu CHANGE ANGLE DIRECTION Visit the direction menu press LA or W to select the direction PaS Positive means clockwise direction and nE amp negative is counter clockwise direction After setting the direction continuously press S S to skip out the setup menu and go back to the current target angle screen PoS Pres
3. INSTRUCTION MANUAL PRODUCT TYPE DIGITAL ANGLE METER WITH MAGNET MODEL 7700 0001 DEAR USER Thank you for purchasing this digital angle meter This manual will help you to use the many features of your new digital angle meter Before operating the meter please read this manual completely and keep it nearby for future reference MAIN FEATURES Digital angle value readout 2 rotating 90 at speed of 30 sec CW and CCW operation Buzzer and LED indicator for the 9 pre settable target angles 50 data memory for recall and angle auditing Auto power off after about 2 minutes idle AAA regular and rechargeable batteries are compatible NAMES AND FUNCTIONS OF PARTS Imre mm DEDO DEMONIOS Buzzer LCD readout Pre set target angle Y Je selection button mA a A Start setting button Up button gt NA Dom button OSA Power on reset button SPECIFICATIONS 7700 0001 2 for 90 rotation 30 sec Data memory size PC connectivity 2 Button Battery 3 Angle accuracy 1 Display range Vibration test 4 Operating temperature Storage temperature Humidity Drop test Electromagnetic Pass compatibility test 6 Communication port Battery compartment Magnet Note 1 The accuracy of the readout is guaranteed from 0 0 to 360 0 and the test speed is 30 sec For maintaining accuracy calibrate the meter at re
4. eter 6 Keep this meter away from magnets 7 Do not expose this meter to dust or sand as this could cause serious damage 8 Do not apply excessive force to the LCD panel BATTERY MAINTENANCE 1 When the meter is not going to be used for an extended period of time remove the batteries 2 Keep a spare battery on hand when going on a long trip or to cold areas 3 Do not mix battery types or combine used batteries with new ones 4 Sweat oil and water can prevent a battery s terminal from making electrical contact To avoid this wipe both terminals before loading a battery 5 Dispose of batteries in a designated disposal area Do not throw batteries into a fire POLAR TOOLS A S SOLDALEN 9 7100 VEJLE DENMARK INFO POLARTOOLS COM WWW POLARTOOLS COM
5. gular intervals 1 year recommended 2 Use a special designed cable accessory to upload record data to PC 3 Two AAA batteries Toshiba carbon zinc RO3UG battery 4 Horizontal and vertical test 5 Environmental test a Dry heat b Cold c Damp heat d Change of temperature e Impact shock f Vibration g Drop 6 Electromagnetic compatibility test a Electrostatic discharge immunity ESD b Radiation susceptibility RS c Radiation emission RE BEFORE USING THE METER Battery Installation Auto Power Off Loosen the screw of the battery cap The meter will auto power off after about 2 minutes Insert two AAA batteries matching the polari idle for power saving ties of the battery to the battery compartment aF h meb Caution asten the screw ot the battery cap During communication period SEnd__ appears the auto power off function is disabled e Zero Reset Press for zero reset n w Usually press to zero reset the digital angle meter before using E I Power On the meter It will guarantee a better CO gt accuracy Press Gently press C to power on First the direction sign PoS or nEG will show Then the LCD shows 9999 It indicates Caution the meter is under resetting process Finally if A During resetting process never vibrate or the reset process is completed the target angle shake the meter Keep it rest If Er Y will be shown For exam
6. ple d is shown shows refer to ERROR MESSAGE section ly Hardware Reset Eo 9900 gt 200 gt S N Current Press C To do hardware rest use a pin to touch the reset target angle button which is located in the hole of the meter back Another way is remove battery and re install it Caution A During resetting process never vibrate or f the meter does not work functionally please do shake the meter Keep it rest hardware reset ERROR MESSAGES A Low Voltage Indicator Er4 f the battery voltage is too low the meter will If the meter does not reset successfully for a display a battery symbol and then turn off period of time 4 will be shown Press to Replace batteries J 5 1 naw Baten do zero reset again Notice that during resetting Aue indicator process never vibrate or shake the meter Keep it rest Er5 5 shows that the meter does not work Er functionally please do hardware reset f the meter rotates too fast Er will be shown Refer to HARDWARE RESET Do press to zero reset the meter OPERATION 1 Put the meter on the wrench Get started fast Press to power on Press M or A Wto set target angle Press S S to start the angle measurement Start rotation Rotation stop and the LCD will be flashing Now press M to record angle or press to clear or press S S to count from current angle 2 Power on the me
7. s A or V NEL VIEW ANGLE RECORD Visit the record menu press A or V to select the data number and view it apil lt 303 Press A or V to select data f no record exists non will be shown Continuously pressing S S will skip out the setup menu and go back to the current target angle screen CLEAR A SINGLE RECORD Visit the record menu Press A or V or to select the data number you want to delete Press C twice to delete the current data dEL will be shown Press A or Vv me a gt n to select data No nu ic 303 Press C nar Press S S Press C Abandon dEl If press once no will be shown If you want to abandon just press S S to skip out this menu Continuously pressing S S will skip out the setup menu and go back to the current target angle screen CLEAR ALL RECORDS isit the record clear all menu Press C twice to delete the all record data dEL will be shown Cir fi Press nor Press S S Press C Abandon dEl If press once na will be shown If you want to abandon just press S to skip out this menu Continuously pressing 9 will skip out the setup menu and go back to the current target angle screen COMMUNICATION Precaution 1 Communication function is only supported on some models Check the model no and its specification before using communication function 2 Do not insert the plug
8. ter and reset 4 Pre tighten wrench Press to power on the meter or reset it Hold on your wrench to pre tighten the screw Finally the current target angle will be shown eliminate the backlash of wrench Make sure the direction If you want to change to direction please refer to CHANGE ANGLE DIRECTION Pre tighten l aa DI PoS si 0000 da dub Positive 4 IN Current direction target angle o T Press 3 Set target angle 5 Start to measure angle Press M to select the pre set target angle M1 M9 Press SIS to start the angle meter and immediately Or press A or W to modify the current target pul your aranin angle Note that the target angle will be saved automatically with the current M number pe a nn a Press S S Press MI to select angle Press A or Vv to modify target angle 6 Stop and wait for LCD Flashing As the angle meter does not move for a few seconds the LCD screen will be flashing and the current angle is holding on screen It also means the meter stop calculating angle N 3093 S Flashing N Note 1 There are 6 LEDs to indicate the current angle reaching 80 85 90 95 97 5 and 99 5 of target angle 99 5 97 5 95 90 85 80 2 There is also a buzzer to indicate the reaching level of target angle Interval sound means it reaches over 80 and long sound means it reaches over 99 5 of target angle A yy gt over 8

Download Pdf Manuals

image

Related Search

Related Contents

User Manual - Newegg.com  LightIt! 30015-308 Instructions / Assembly  split-type air conditioners - Mitsubishi Electric Cooling & Heating  Mode d'emploi Gebruiksaanwijzing Operating instructions  User Manual - Sütron electronic GmbH  FONIX® 7000 - Frye Electronics  Tuning Box V2.0 [MISCE0020000000] – User Manual  MINI-DMX - Audiofanzine    OPERATING INSTRUCTIONS  