Home
AFOLUX LX Series Flat Panel PC User Manual
Contents
1. 100 B 2 TOUCH PANEL DRIVER eee tete reet 100 B 2 1 Introduction sencan ranni E EAE 100 B 2 2 Driver Installation eese EE E EE 101 B 2 3 Touch Panel Driver Config WFGROTR GUAE ER ERR KIA 104 _ AFOLUX LX Series Flat Panel List of Figures Figure 1 1 Front 4 Figure 1 2 AFL 07A LX AFL 08A LX Rear View 5 Figure 1 3 AFL 08A LX Top 5 Figure 1 4 AFL 08A LX Side View 2 eene nne 5 Figure 1 5 AFOLUX LX Series Bottom 6 Figure 1 6 AFL 07A LX Dimensions units in 22222 12 Figure 1 7 AFL 08A LX Dimensions units in MM eere 13 Figure 1 8 AFL 12A LX Dimensions units in MM eere 14 Figure 2 1 AFLMB LX800 Connector Overview eres 22 Figure 3 1 Back Cover Retention Screws eese 27 Figure 3 2 AFL 08A LX Plastic Back Cover 27 Figure 3 3 CF Card 28 Figure 3 4 AFL 08A LX Plastic Back Cover Replacement
2. 62 IDE Primary Master Auto ener enne nnne 62 Access Mode 62 Cc 63 Cylinder 2 63 Head 4 4024 0 63 63 Landing 20 eet dette 64 zl 64 BIOS Menu 3 Advanced BIOS 64 Virus Warning Disabled essere eene enne nnn nnne 65 CPU Internal Cache 1 2 22 2 65 Quick Power On Self Test Enabled eee 65 Page 94 AFOLUX LX Series Flat Panel PC _ 0 RITechnology Corp Boot From LAN Control 2 22 22 1 66 B ot Deyice Acc 66 Boot Other Device Enabled cessere eene 67 Boot Up Numlock Status On cecinere ennt 67 Gate A20 Option noo cu nnno denn nno o Ex nnnc n vanno sU a 67 Typematic Rate Setting Disabled eene 68 Typematic Rate Chars sec 6 68 Typematic Delay Msec 250
3. 222222 22 44 222 2 9 Table 1 4 TFT LCD Monitor Specifications eere 10 Table 1 5 Touch Panel nnn 11 Table 2 1 Geode LX Graphics 2 2 2 4 4 2 22 19 Table 4 1 9 Signal Select Jumper Settings 52 Table 4 2 COM1 and 2 Pin 9 Signal Select Jumper Settings 53 Table 5 1 BIOS Navigation 57 lt gt RIechnology Corp AFOLUX LX Series Flat Panel PC Chapter 1 Introduction _ IE AFOLUX LX Series Flat Panel 1 1 AFOLUX LX Series Flat Panel PC Overview The AFOLUX LX series flat panel PC is a flexible multi functional and fanless flat panel PC that can be applied in diverse operational environments and implemented in multi faceted applications The AFOLUX LX series comes fully kitted with a high performance motherboard and a host of other peripheral interface connectors The integrated wireless LAN module and PIFA antenna ensure an uninterrupted wireless connection The AFOLUX LX series is designed for ease of use and easy installation 1 1 1 Model Variations The models of AFOLUX LX series are lis
4. 1 1 1 AFOLUX LX SERIES PLAT PANEL PG OVERVIEW iater terre estesa 2 1 1 1 Model Trivium 2 2 Applications 2 PT Standard Features 2 1 2 s uci FU OVERVIEW PC tees 4 1 2 1 General a pao 4 1 2 2 Front Pa el T 4 t23 4 1 2 4 Panel 2 12 3 Bottom 6 1 3 INTERNAL OVERVIEW sc T 6 E A E EEE SEa 6 1 4 1 Preinstalled Hardware 6 1 4 2 System SVECHICULIONS 7 1 4 3 Motherboard 5 8 144 Flat Panel Screen Specifications UT Ee 9 1 4 5 Touch Screen 11 12 LO AFL 07A LX DUCTS OMS 12 13 2 AFL OSA LX TOMS 13 15 3 AFL 2A LX Dimensions ge 14 2 MOTHERBOARD
5. 7 10 73 _ 0 RITechnology Corp A n 5 n 3 m o USB 2 0 ect 4 6 8 17 USB connectors 22 Serial port 22 2200 100 8 8 snas 21 49 50 Viewing Angle 7 TOUCH SCrEEN n ie corde tes Wall 4 24 30 31 32 33 TOUCH 5 T wall mounting eene 32 wall mounting bracket 31 8 wireless module 6 44 46 Page 107
6. RIechnology Corp AFOLUX Series Flat Panel PC BIOS Configuration Options Page 93 _ AFOLUX LX Series Flat Panel A 1 BIOS Configuration Options Below is a list of BIOS configuration options described in Chapter 5 BIOS Menu 1 Award BIOS CMOS Setup Utility eese 57 Load Fail Safe Defaults 58 Load Optimized 58 Set Supervisor Password 58 Set User Password 59 amp EMM EE 59 Exit Without SAVING EP 59 BIOS Menu 2 Standard CMOS Features 60 Date Day 60 Time hh mm s5 retirer 60 IDE Master and IDE Slave 60 Halt On But Keyboard 61 lup 61 Extended Memory erecto 61 Total 222222222 61 IDE HDD Auto Detection Press
7. IEI Technology Corp 1 bh Y ALA series Fanless All in one Panel PC with AMD LX 800 CPU TFT LCD Wireless LAN Touch Screen and IP 64 Protection User Manual Rev 1 0 January 2007 AFOLUX LX Series Flat Panel PC Revision MODEL AFOLUX LX Series Flat Panel PC User Manual Revision Number Description Date of Issue 1 0 Initial release January 2007 AFOLUX LX Series Flat Panel PC _ 0 RTechnology Corp Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability design and function and does not represent a commitment on the part of the manufacturer In no event will the manufacturer be liable for direct indirect special incidental or consequential damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS IBM PC is a registered trademark of International Business Machines Corporation INTE
8. 28 Figure 3 5 AFL 12A LX Aluminum Back Cover Retention Screws 29 Figure 3 6 Four Hexagonal Pillars on the Bottom 29 Figure 3 7 AFL 12A LX HDD Bracket Retention 30 Figure 3 8 AF 12A LX HDD Retention Screws eese 30 Figure 3 9 Wall mounting 32 Figure 3 10 Chassis Support 5 5 32 Figure 3 11 Secure the Panel 33 Figure 3 12 AFL 07A LX Panel 34 Figure 3 13 AFL 08A LX Panel ennt 35 Figure 3 14 AFL 12A LX Panel nnn 35 Figure 3 15 Tighten the Panel Mounting Clamp Screws AFL 12A LX 36 Figure 3 16 AFL 07A LX AFL 08A LX Arm Mounting Retention Screw Holes 37 Figure 3 17 AFL 12A LX Arm Mounting Retention Screw Holes 38 Figure 3 18 Rack Cabinet Bracket eese 38 Figure 3 19 Secure the Rack Cabinet Bracket AFL 12A LX 39 Page xii AFOLUX LX Series Panel PC
9. 89 Reset Configuration Data Disabled 89 Page 96 AFOLUX LX Series Flat Panel PC 1 RIechnology Corp Resources Controlled By Auto ESCD eese 89 x IRQ Resources Press Enter eese 89 x Memory Resources Press Enter eee 90 PCI VGA Palette Snoop Disabled eese 90 BIOS Menu 10 PC Health 1 2111 eeeneeee nennt nnne 91 rc cond 91 AFOLUX LX Series Flat Panel THIS PAGE IS INTENTIONALLY LEFT BLANK Page 98 24 lt gt RIechnology Corp AFOLUX Series Flat Panel PC Appendix Software Drivers Page 99 _ IE AFOLUX LX Series Flat Panel B 1 Remote Management Tool IEI provides optional pre installed Windows XP Embedded or Windows CE 5 0 turnkey solutions tailored for the AFOLUX series For information about configuring the operating system adding remote management tools or additional software and drivers refer to the software user manuals on IEI AFOLUX series Utility CD that came with the AFOLUX series flat panel PC B 2 Touch Panel Driver B 2 1 Intr
10. 3 AUGIO 9 18 71 242 5 6 28 49 BGA type dietas iv bottom 40 bracket 4 29 30 31 32 33 38 39 40 2 2 7 10 CD drive eee 100 Certificate n ecce 8 2 pin 9 signal select 51 pin 9 signal select 51 Contrast 7 10 95530 17 10 12 13 14 Ethernet 22 106 AFOLUX LX Series Flat Panel Geode 800 16 Graphics Processor 18 ADD t tet rns 29 62 63 a 76 coc deeds h 21 45 3 Keyboard mouse connector 21 Memory 16 19 49 60 70 71 89 panel mounting clamps 38 39 Panel mounting iv Pixel PIG druide ted vetus 10 Power Consumption 10 power switch 4 Power 6 8 24 Reset 6 8 22 Resolution
11. 45 m 1Min m 5Min m 10Min m 15Min m 30Min _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC 45 Min 60 Min 90 Min 120 Min Modem Use of IRQ Use the Modem Use of IRQ to select the IRQ address for the system modem The following IRQ addresses are available a m 3 Default a 4 E 5 7 m 10 m 11 Wake on Lan Control Disabled Use the Wake on Lan Control option to enable activity on the LAN to rouse the system from a suspend or doze state gt Disabled Default Wake event not generated by LAN activity gt Enabled Wake event generated by LAN activity Soft Off by PWR BTTN Instant Off Use the Soft Off by PWR BTTN option to enabled the system to enter a very low power usage state when the power button is pressed gt Instant Off Default When the power button is pressed the system is immediately shutdown gt Delay 4 shutdown the system the power button must be held Page 85 _ AFOLUX LX Series Flat Panel PC down longer than four seconds otherwise the system enters a low power usage state Power On by Alarm Disabled Use the Power On by Alarm option to specify when the computer is roused from a suspended state gt Disabled Default The real time clock RTC cannot generate a wake event gt Enabled If selected the following appears
12. RIechnology Corp AFOLUX LX Series Flat Panel PC Award BIOS Setup Page 55 _ AFOLUX LX Series Flat Panel 5 1 Introduction A licensed copy of Phoenix Award BIOS is preprogrammed into the ROM BIOS The BIOS setup program allows users to modify the basic system configuration This chapter describes how to access the BIOS setup program and the configuration options that may be changed 5 1 1 Starting Setup The Phoenix Award BIOS is activated when the computer is turned on The setup program can be activated in one of two ways 1 Press the DELETE key as soon as the system is turned on or 2 Press the DELETE key when the Press Del to enter SETUP message appears on the screen If the message disappears restart the computer and try again 5 1 2 Using Setup Use the arrow keys to highlight items press ENTER to select use the PAGEUP and PAGEDOWN keys to change entries press F1 for help and press Esc to quit Navigation keys are shown below Function o O SC E Main Menu Quit and do not save changes into CMOS Status Page Setup Menu and Option Page Setup Menu Exit current page and return to Main Menu F1 General help only for Status Page Setup Menu and Option Page Setup Menu _ o Corp AFOLUX LX Series Flat Panel Previous values for the page menu items Fail safe defaults for the curr
13. esses 55 5 INTRODUCTION ici eee tret re ore Pe eb tee ee e utebatur bee dee pe 56 3 11 Starting Set p 56 EP 56 51 3 ET o TCL PNE 57 5 1 4 Main BIOS Menu 57 5 2 STANDARD CMOS 6 0 e paene 59 2 4 41 IDE Primary Master Slave 62 5 3 ADVANCED BIOS 8 2 n s s a a a 64 5 4 ADVANCED CHIPSET 86 0 n n n n n n n n nae 70 5 4 1 Flat Panel 1 ubt ode exa AD 73 5 5 INTEGRATED PERIPHERALS 76 5 6 POWER MANAGEMENT 6 1 n n n n n n nn nn 81 5 7 PNP PCI 222 88 5 8 HEALTH STATUS tee eth tee 91 A BIOS CONFIGURATION OPTIONS 93 1 BIOS CONFIGURATION 65 4 000004000 94 B SOFIWARE DRIVERS 2 sa bare Pao apa proa PE Pop Depas EP 99 REMOTE MANAGEMENT TOOL
14. RITechnology Corp AFOLUX LX Series Flat Panel PC m Provides LED pins for network operation status indication m 2 5 3 3V power supply with 5V tolerant I Os 2 6 Peripheral Device Interfaces Connectors and Slots The peripheral device connectors interfaces and slots on the WAFER LX motherboard are listed in the sections below 2 6 1 OEM Options Many of the peripheral device connectors listed below are not connected to any devices These connectors are reserved for OEM customizations For a customized option please contact the vendor reseller IEI sales representative 2 6 2 Internal Slots The slots listed below can all be found on the WAFER LX motherboard m 1 200 DDR SO DIMM socket 1 slot 2 6 3 Internal Peripheral Device Connectors The peripheral device connectors listed below are located on the AFLMB LX800 motherboard and used for the AFOLUX series Figure 2 1 shows the overview of the connectors that are used for the AFOLUX series m 1 x Audio connector m 1 CompactFlash CF slot m 1 Inverter connector m 1x LCD interface connector m 1x LED connector m 1 x Mini PCI socket for wireless LAN module m 1 Power switch connector m 1x Touch screen connector IE AFOLUX LX Series Flat Panel PC LCD Connector Touch Screen Inverter Connector Mini PCI Wireless LAN Module IDE CF Slot EXE Audio Connector
15. cnra heus 74 HSYNC Polarity LOW 4 eic reconoce eiie ceu rur ch 75 VSYNC Polarity Active 75 SHFCLK Active Period Free Running eene 75 LP Active Period Free 1 2224222 22 222 75 BIOS Menu 6 Integrated 76 On Chip IDE Channel 1 Enabled eene 76 _ Driv PIO Mode AU to 5 76 77 IDE DMA transfer access 77 IDE HDD Block Mode Enabled 78 Onboard Serial Port 1 3F8 IRQ94 e 78 Onboard Serial Port 2 2F8 IRQ3 cerent 78 Onboard Parallel Port 378 1 79 Parallel Port Mode 79 EPP Mode Select EPP4 7 ciet 80 ECP Mode Use 3 80 Onboard Serial Port 3 8 80
16. 68 Security Option Setup eerte ertet eret 69 OS Select For DRAM gt 64MB 2 69 Small Logo EPA Show Disabled eere 70 BIOS Menu 4 Advanced Chipset Features 70 CPU Frequency 500 21 2 71 Memory Frequency 71 CAS Latency Auto tonitru 71 Interleave Select LOI 71 Video Memory Size creare ruin ccena 72 Output Display Panel nnn 72 Flat Panel Configuration Press 422 12222 72 OnBoard Audio 72 BIOS Menu 5 Flat Panel Configuration 73 Flat Panel Type AU O 73 Resolution 800 x 6001 2 eene enn nn annnm nnmnnn nnna 74 Data Bus 9 24 bits 1 74 Refresh Rate 60 2 ecouter node apnea
17. host ports 1 host device _ IE AFOLUX LX Series Flat Panel Audio Codec 97 AC97 Controller AC97 specification v2 3 compliant interface to multiple audio codecs Serial In Serial Out Sync Out Bit Clock In Legacy PC support Diverse Device 82xx Legacy Devices IR Communication Port System Management Bus SMB Controller LPC Low Pin Count Port General Purpose 1 GPIOs 8 Multi Function General Purpose Timers MFGPTs Real Time Clock RTC with CMOS RAM Power Management Controller ACPI v2 0 compliant O O O O O 2 4 Graphics Support The Geode LX processor s Graphics Processor is BitBLT vector engine that supports pattern generation source expansion pattern source transparency 256 ternary raster operations alpha blenders to support alpha BLTs incorporated BLT FIFOs a GeodeLink interface and the ability to throttle BLTs according to video timing New features added to the Graphics Processor include Table 2 1 Command buffer interface Hardware accelerated rotation BLTs Color depth conversion Paletized color Full 8x8 color pattern buffer Separate base addresses for all channels Monochrome inversion Geode LX Graphics Features lists a complete list of Geode LX graphics features For more details please refer to the AMD website or the Geode LX series data book available from AMD AFOL
18. 15 EEE TER 16 2 2 CPU SUPPORT eiren OT Cm 16 2 2 1 AMD Geode LX 800 500MHz Specifications e 16 2 2 2 AMD Geode M LX 800 5 00MHz Power 17 2 3 SYSTEM 0000000 17 _ IE T echnology Gorp AFOLUX LX Series Flat Panel PC eR PUTET 20 20 2 6 PERIPHERAL DEVICE INTERFACES CONNECTORS AND 51 0 6 4 21 20 1 OEM ODORE esed iiid be MM iuda 21 220 2 Internal s esiste acs Oeo ated qM 21 2 6 3 Internal Peripheral Device Connectors eee e etie ea inte atas dieta anta aae nda 21 2 6 4 External Peripheral Device uiii reti terni xpo aan ta HERE Ie Ra RASA A 22 55566 QUE DE ON E RUE FRE OQ VIV KP 23 3 1 INSTALLATION PRECAUTIONS 24 3 2 PREINSTALLED COMPONENTS sites etra de ide t ttp Stop DLE ra nis oci Reais 24 3 3 INSTALLATION AND CONFIGURATION STEPS a adis 24 t nr trc 25 34 1 Packing NK aa ue MU AD Ad tuu 26 3 3 CF CARD INSTALLATION T 27 28 3 7 MOUNTING THE
19. Step 1 Step 2 Step 3 Step 4 Step 5 Select the location on the wall for the wall mounting bracket Carefully mark the locations of the four brackets screw holes on the wall Drill four pilot holes at the marked locations on the wall for the bracket retention Screws Align the wall mounting bracket screw holes with the pilot holes Secure the mounting bracket to the wall by inserting the retention screws into the four pilot holes and tightening them Figure 3 9 IE AFOLUX LX Series Flat Panel PC Figure 3 9 Wall mounting Bracket Step 6 Insert the four monitor mounting screws provided in the wall mounting kit into the four screw holes on the real panel of the flat panel PC and tighten until the screw shank is secured against the rear panel Figure 3 10 Step 7 Align the mounting screws on the monitor rear panel with the mounting holes on the bracket Step 8 Carefully insert the screws through the holes and gently pull the monitor downwards until the monitor rests securely in the slotted holes Figure 3 10 Ensure that all four of the mounting screws fit snuggly into their respective slotted holes Figure 3 10 Chassis Support Screws EE RIechnology Corp AFOLUX LX Series Flat Panel PC In the diagram below the bracket is already installed on the wall Step 9 Secure the panel PC by fastening the re
20. down it begins to report that the key has been pressed repeatedly This feature accelerates cursor movement with the arrow keys Disabled Default Enabled Disables the typematic rate Enables the typematic rate Typematic Rate Chars sec 6 The Typematic Rate option can only be configured if the Typematic Rate Setting is enabled Use the Typematic Rate option to specify the rate keys are accelerated gt vv 20 24 30 Default 6 characters per second 8 characters per second 10 characters per second 12 characters per second 15 characters per second 20 characters per second 24 characters per second 30 characters per second Typematic Delay Msec 250 The Typematic Rate option can only be configured if the Typematic Rate Setting is enabled Use the Typematic Delay option to specify the delay time between when a key is first pressed and when the acceleration begins _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC gt 250 Default 250 milliseconds gt 500 500 milliseconds gt 750 750 milliseconds gt 1000 1000 milliseconds Security Option Setup Use the Security Option to limit access to both the system and Setup or just Setup gt Setup Default system does not boot and access to Setup is denied if the correct password is not entered at the prompt gt System The system boots but access to Setup
21. AFL 07A LX AFL 08A LX Rear View 1 2 4 Top Panel and Side Panels The top panel and side panels of AFOLUX LX series provides access to slots that support panel mount and rack mount Figure 1 3 and Figure 1 4 Clamps Insertion Slots EI A Figure 1 3 AFL 08A LX Top View Clamps Insertion Slots fl Figure 1 4 AFL 08A LX Side View gt AFOLUX LX Series Flat Panel PC 1 2 5 Bottom Panel The bottom panel of the AFOLUX LX series has the following I O interfaces Figure 1 5 m 2 x RS 232 serial port connectors m 1 power adapter connector m 2xRJ 45 10 100Mbps Ethernet connectors m 2xUSB 2 0 connectors m 1 Power switch m 1 x Reset button Power Connector Serial Ports Power Switch Ethernet Reset Button Figure 1 5 AFOLUX LX Series Bottom View 1 3 Internal Overview The AFOLUX LX series internal components are protected in an aluminum chassis inside the plastic back cover The motherboard wireless LAN module and DDR memory module are installed on a metal sheet that protects the rear of the TFT LCD screen Below the metal sheet is a circuit board that is connected to the screen and the motherboard 1 4 Specifications 1 4 1 Preinstalled Hardware Components The AFOLUX LX series flat panel PC has the following preinstalled components m 1 Motherboard m 1xTFT LCD screen m 1x Touch screen AFOLUX LX Series Flat Panel PC m 1 Inverter
22. AFOLUX LX Series Flat Panel settings Resolution 800 x 600 The Resolution option can only be configured if the Flat Panel Type option is not set to Auto Use the Resolution option to set the resolution of the flat panel screen connected to the system The Resolution options are m 320x240 m 640x480 800 x 600 Default m 1024 768 m 1152 864 1280 x 1024 1600 x 1200 Data Bus Type 9 24 bits 1 ppc The Data Bus Type option can only be configured if the Flat Panel Type option is not set to Auto Use the Data Bus Type option to set the bus type and the data bus width used to transfer data between the system and the flat panel screen connected to the system The Data Bus Type options are m 9 24 bits 1 ppc Default m 18 24 bits 2 ppc Refresh Rate 60Hz The Refresh Rate option can only be configured if the Flat Panel Type option is not set to Auto Use the Refresh Rate option to set the screen refresh rate required by the panel connected to the system Check the documentation that came with the panel before setting this option The Refresh Rate options are 60Hz Default 70Hz m 72Hz _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC m 75Hz m 85Hz m 90Hz wm 100Hz HSYNC Polarity Low The HSYNC Polarity option can only be configured if the Flat Panel Type option is not set to Auto Use the HSYNC Polarity option to set the polarity of the HSYNC
23. m 1xWireless LAN module m 1xDDR memory module _ 0 RITechnology Corp The technical specifications for some of these components and the system are shown in the sections below 1 4 2 System Specifications The technical specifications for the AFOLUX LX series systems are listed in Table 1 2 SPECIFICATION AFL 07A LX AFL 08A LX AFL 12A LX Front Panel ABS PC plastic front panel Chassis Aluminum chassis LCD Panel 8 4 12 1 Resolution 800 x 480 800 x 600 1024 x 768 Brightness 220 cd m 220 cd m 450 cd m Contrast Ratio 400 1 500 1 700 1 Viewing Angle H V 140 100 130 110 160 160 Backlight MTBF 30000 20000 50000 Touch Screen 4 wire resistive type 4 wire resistive type 5 wire resistive type SSD CompactFlash Type II Audio AMP 1 5W AMP 1 5W internal speaker Extension 1 x Mini PCI for wireless LAN module Drive Bay N A N A 1 x 2 5 HDD bay _ IE IT echnology Gorp AFOLUX LX Series Flat Panel PC SPECIFICATION AFL 07A LX AFL 08A LX AFL 12A LX 2 x RS 232 serial port 2 x 10 100 Mbps Ethernet port 2 x USB 2 0 port 1 x Power switch 1 x Reset button Power 12V 45W DC power adapter Power Consumption 20W 20W 29W Mounting Feature Panel Wall Arm Stand Operating Temperature 0 C 50 C 0 50 C 0 C 50 C 0 40 C using HDD Relative Humidity 5 8096 RH
24. 12A LX flat panel PC are shown in Figure 1 7 below 2 9 A 304 247 99 186 49 Figure 1 8 AFL 12A LX Dimensions units in mm lt gt RIechnology Corp AFOLUX LX Series Flat Panel PC Motherboard Page 15 _ IE T echnology Gorp AFOLUX LX Series Flat Panel PC 2 1 Introduction The AFOLUX LX series flat screen PC contains the AFLMB LX800 motherboard The motherboard is the heart of any computer and is responsible for transmitting receiving and processing data as well as driving the different onboard devices This chapter gives a brief introduction to the AFLMB L X800 motherboard 2 2 CPU Support The AFLMB LX800 motherboard comes with a preinstalled Geode LX 800 500MHz CPU 2 2 1 AMD Geode LX 800 500MHz Specifications The specifications for the 500 2 AMD Geode LX 800 are listed below m x86 x87 compatible core m Processor frequency up to 500 MHZ 64 64 L1 cache and 128K L2 cache m Split cache TLB Translation Look Aside Buffer m 64 bit DDR Memory interface up to 400MHz LX 800 up to 333MHz LX 700 m Integrated FPU that supports the Intel MMX and AMD 3DNow Technology instruction sets m 9 GB s internal GeodeLink Interface Unit m Security Block 128 bit AES CBC ECB O True Random Number Generator m High resolution CRT and TFT outputs simultaneous operatio
25. Power Switch LED Connector Connector Figure 2 1 AFLMB LX800 Connector Overview 2 6 4 External Peripheral Device Connectors The peripheral device connectors listed below are located on the rear panel of the AFLMB LX800 motherboard m 2 x Ethernet connectors m 2xUSB connectors m 2x Serial port connectors m 1 x Reset button m 1 Power connector lt gt RIechnology Corp AFOLUX Series Flat Panel PC Installation Page 23 _ IE IT echnology Gorp AFOLUX LX Series Flat Panel PC 3 1 Installation Precautions When installing the flat panel PC please follow the precautions listed below Power turned off When installing the flat panel PC make sure the power is off Failing to turn off the power may cause severe injury to the body and or damage to the system Certified Engineers Only certified engineers should install and modify onboard functionalities Mounting The flat panel PC is a heavy device When mounting the system onto a rack panel wall or arm please make sure that at least two people are assisting with the procedure Anti static Discharge If a user open the rear panel of the flat panel PC to configure the jumpers or plug in added peripheral devices ground themselves first and wear and anti static wristband 3 2 Preinstalled Components The following components are all preinstalled Motherboard TFT LCD screen 256MB 512MB DDR memory module
26. SYSTEM 30 ten 21 5 7 2 Panel Mo ntin p 39 3 7 3 Arm Mounting EP E 36 3 7 4 Cabinet and Rack Installation 38 39 9 BOTTUM ONNBCTORS dead 40 3 8 1 Ts Dou EORR 40 40 3 6 3 USB CONNECTION I 40 SYSTEM MAINTENANCE ssccssvassccssecvsvassnseassopvasekcsensstedanvevakedseiabnsentoontcansivikesnniss 43 4 1 SYSTEM MAINTENANCE INTRODUCTION 44 4 2 MOTHERBOARD REPLACEMENT d tende 44 4 3 INTERNAL ALUMINUM COVER REMOVAL ta theta oe taba 44 4 3 1 AFL 07A LX Internal Aluminum Cover Remowval eese 45 4 3 2 AFL 08A LX Internal Aluminum Cover 46 4 3 3 AFL 12A LX Internal Aluminum Cover 48 4 4 MEMORY MODULE REPLACEMENT EE Qe E pad PUER 49 4 5 JUMPER SET TINGS 50 _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC 4 5 1 JP3 Pin 9 Signal Select Jumper Settings 51 4 5 2 7 4 COMI 9 Signal Select Jumper Settings 53 5 AWARD BIOS SETUP
27. Select No if PCI UGR Palette Snoop Disabled you need the BIOS to configure non boot devices 5 Jl D Value F10 Save e Defaults BIOS Menu 9 PnP PCI Configurations PNP OS Installed No The PNP OS Installed option determines whether the Plug and Play devices connected to the system are configured by the operating system or the BIOS gt Default 1f the operating system does not meet the Plug and Play specifications BIOS configures all the devices in the system gt Yes Set this option if the system is running Plug and Play aware operating systems The operating system changes the interrupt and DMA settings _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC Init Display First Onboard Use the Init Display First option to select the primary display device gt PCI Slot The display connected to the PCI slot is the primary display gt Onboard Default The display connected to the onboard connector is the primary display Reset Configuration Data Disabled Use the Reset Configuration Data option to reset the Extended System Configuration Data ESCD when exiting setup if booting problems occur after a new add on is installed gt Disabled Default ESCD will not be reconfigured gt Enabled ESCD will be reconfigured after you exit setup Resources Controlled By Auto ESCD Use the Resources Controlled By option to ei
28. Some of the standard features of the AFOLUX LX series flat panel PC include m Fanless Design m AMD Geode X 800 processor m Rugged mechanism design with ABS PC case m 64 dustproof and waterproof front panel wm One 256MB 512MB DDR memory module pre installed m Wireless LAN integrated with PIFA antenna m Dual 10 100Mbps Ethernet support m One CompactFlash Type II socket support m Simplified installation process m RoHS compliance 6 AFOLUX LX Series Flat Panel PC 1 2 External Overview 1 2 1 General Description The AFOLUX LX series is a stylish flat panel PC that comprises of a screen rear panel top panel bottom panel and two side panels left and right An ABS PC plastic front frame surrounds the front screen The rear panel provides screw holes for a wall mounting bracket compliant with VESA FDMI standard The bottom panel provides access to external interface connectors that include LAN USB 2 0 serial port reset button power connector and power switch 1 2 2 Front Panel The front side of the AFOLUX LX series is a flat panel TFT LCD screen surrounded by an ABS PC plastic frame Power LED Model Name ABS PC Plastic Frame Screen Figure 1 1 Front View 1 2 3 Rear Panel The rear panel provides access to retention screw holes that support the wall mounting Refer to Figure 1 2 IEI Corp Figure 1 2
29. _ 0 RITechnology Corp Figure 3 20 Install into a nnn 40 Figure 4 1 AFL 07A LX Aluminum Back Cover Retention Screws 45 Figure 4 2 Four Hexagonal Pillars on the Bottom Panel AFL 07A LX 45 Figure 4 3 AFL 08A LX Aluminum Back Cover Retention Screws 46 Figure 4 4 Four Hexagonal Pillars on the Bottom Panel AFL 08A LX 46 Figure 4 5 Wireless Module Cables sees eene 47 Figure 4 6 The Internal Aluminum Cover Removal eene 47 Figure 4 7 Power Switch 48 Figure 4 8 AFL 12A LX Aluminum Back Cover Retention Screws 48 Figure 4 9 Four Hexagonal Pillars on the Bottom Panel AFL 12A LX 48 Figure 4 10 SO DIMM Socket Location 49 Figure 4 11 DDR SO DIMM Module Installation 50 Figure 4 12 Jumper 5 51 Page xiii _ AFOLUX LX Series Flat Panel List of Tables Page xiv Table 1 1 Model 2 Table 1 2 AFOLUX LX Series System Specifications 8 Table 1 3 Motherboard
30. connector is a standard connector and can easily be connected to other USB devices AFOLUX LX Series Flat Panel THIS PAGE IS INTENTIONALLY LEFT BLANK Page 42 24 a 2 lt gt RIechnology Corp AFOLUX Series Flat Panel PC Chapter 4 System Maintenance Page 43 6 4 1 System Maintenance Introduction AFOLUX LX Series Flat Panel PC If the components of the AFOLUX LX series fail they must be replaced such as the wireless LAN module or the motherboard Please contact the system reseller or vendor to purchase the replacement parts Back cover removal instructions and jumper settings for the AFOLUX LX series are described below 4 2 Motherboard Replacement A user cannot replace a motherboard If the motherboard fails it must be shipped back to to be replaced If the system motherboard has failed please contact the system vendor reseller or an IEI sales person directly 4 3 Internal Aluminum Cover Removal WARNING BEFORE REMOVING THE BACK COVER MAKE SURE THE POWER IS OFF Failing to do so may lead to severe damage of AFOLUX LX series and injury to the body WARNING PLEASE TAKE ANTISTATIC PRECAUTIONS WHEN WORKING WITH THE INTERNAL COMPONENTS The interior of the AFOLUX LX series contains very sensitive electronic components These components are easily d
31. mentioned in the cleaning tips m Cloth piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on most hardware as well it is recommended to rub it with a piece of cloth wm Water or rubbing alcohol Moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the computer m Unknown solvents may be harmful to the plastics parts m Vacuum cleaner Absorb the dust dirt hair cigarette particles and other particles out of a computer can be one of the best methods of cleaning a computer Over time these items can restrict the airflow in a computer and cause circuitry to corrode m Cotton swabs Cotton swabs moistened with rubbing alcohol or water are Page vii _ excellent tools for wiping hard to reach areas the keyboard mouse and AFOLUX LX Series Flat Panel PC other locations m Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs ESD PRECAUTIONS Observe all conventional anti ESD methods while handling the components contained within the LCD should the need arise for adding a functionality The use of a grounded wrist strap and an anti static work pad is recommended Avoid dust and debris or other static accumulating materials in the work area Page viii mme RITechnology Corp IL INTRODUCTION uec DA EE
32. non condensing Vibration 5 17Hz 0 1 double amplitude displacement 17 640Hz 1 5G acceleration peak to peak Shock 10G Acceleration peak to peak 11ms Dimension WxHxD 226 x 140 x 41 234 x 184 x 42 304 x 246 x 50 Net Gross Weight 0 6 Kg 0 8 Kg 1 8 Kg Front Panel Protection 64 compliant Safety Meets UL CE EMC Meets CE FCC class B Table 1 2 AFOLUX LX Series System Specifications 1 4 3 Motherboard Specifications The AFOLUX LX series come with AFLMB LX800 motherboard The technical specifications of the motherboard are listed in Table 1 3 AFOLUX LX Series Panel PC 2 jTechnology Corp Specification AFLMB LX800 CPU AMD LX 800 500Mhz Southbridge Chipset AMD Geode CS5536 Display CRT integrated in AMD Geode LX800 24 bit TTL integrated in AMD Geode LX800 18 bit LVDS supported by buffer 8 4 Memory Supports one 1GB DDR 333 400 200 pin SO DIMM SDRAM module Extension One mini PCI slot BIOS Award BIOS SSD CFII Super I O N A for legacy free Audio AC 97 Codec Realtek ALC203 AMP 1 2W LAN 10 100 Base T dual RTL8100C COM Two RS 232 serial ports IDE One 44 pin IDE connects to two IDE devices Touch Screen Controller DMC9000 Power Supply 12V ATX power support Dimensions 102mm x 186mm Table 1 3 Motherboard Specifications 1 4 4 Flat Panel Screen
33. options are m Disabled m 378 IRQ7 Default m 278 IRQ5 3BC IRQ7 Parallel Port Mode SPP Use the Parallel Port Mode option to select parallel port operation mode gt spp Default gt Epp ECP EPP Normal The parallel port operates in the standard parallel port SPP mode This parallel port mode works with most parallel port devices but is slow The parallel port operates in the enhanced parallel port mode EPP The EPP mode supports bi directional communication between the system and the parallel port device and the transmission rates between the two are much faster than the SPP mode The parallel port operates in the extended capabilities port ECP mode The ECP mode supports bi directional communication between the system and the parallel port device and the transmission rates between the two are much faster than the SPP mode The parallel port is compatible with both ECP and EPP devices _ IE gt EPP Mode Select EPP1 7 AFOLUX LX Series Flat Panel PC The EPP Mode Select option is only available if the Parallel Port Mode option is set to EPP mode Use the EPP Mode Select option to select the parallel port mode standard for the parallel port 1 9 EPP 1 9 is selected as the EPP standard gt EPP1 7 Default EPP 1 7 is selected as the EPP standard ECP Mode Use 3 The ECP Mode Use D
34. the chassis Figure 3 2 AFL 08A LX Plastic Back Cover Removal Step 3 Locate the CF slot Insert a CF card into the slot Figure 3 3 IE IT echnology Gorp AFOLUX LX Series Flat Panel PC Figure 3 3 CF Card Location Step 4 Replace the plastic back cover For AFL 08A LX more strength is required when pushing the bottom part of the cover down to the chassis Figure 3 4 Figure 3 4 AFL 08A LX Plastic Back Cover Replacement Step 5 Once replaced reinsert the nine previously removed retention screws 3 6 HDD Installation AF 12A LX Only To install the HDD into the AF 12A LX please follow the steps below Step 1 Remove the plastic back cover See Section 3 5 above Step 2 Remove the eight retention screws securing the internal aluminum cover Figure 3 5 c 6 IEI jTechmnology Corp Figure 3 5 AFL 12A LX Aluminum Back Cover Retention Screws Step 3 Remove the four hexagonal pillars on the bottom panel a Figure 3 6 Four on the Bottom Panel Step 4 Push the external interface connector apart from the aluminum cover and lift the aluminum cover off the AFL 12A L X Step 5 Disconnect the power switch cable from the motherboard and remove the aluminum cover Step 6 Remove the four HDD bracket retention screws Figure 3 7 and lift the HDD bracket off the panel P
35. 0 0 m SCSI CDROM HDD 1 m USB FDD _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC USB ZIP m USB CDROM USB HDD m LAN m Disabled Boot Other Device Enabled Use the Boot Other Device option to determine whether the system uses a second or third boot device if the first boot device is not found gt Disabled The system does not look for second and third boot devices if the first one is not found gt Enabled Default system looks for second and third boot devices if the first one is not found Boot Up Numlock Status On Use the Boot Up Numlock Status option to specify the default state of the numeric keypad gt Off The keys on the keypad are not activated gt Default Activates the keys on the keypad Gate A20 Option Fast Use the Gate A20 Option to set if the keyboard controller or the chipset controls the Gate A20 switching gt The keyboard controller does the switching gt Default chipset does the switching _ IE gt AFOLUX LX Series Flat Panel Typematic Rate Setting Disabled Use the Typematic Rate Setting configuration option to specify if only one character is allowed to appear on the screen if a key is continuously held down When this option is enabled the BIOS reports as before but it then waits a moment and if the key is still held
36. 1 HDD 01 1001 Fast Gate AZ Typemat ic Typemat ic T2 abled Enabled Disabled Enabled Disabled Item Help and someon write data into this warn T Ma nu Level L4 BIOS will show j age on nd alarm beep BIOS Menu 3 Advanced BIOS Features _ 0 RTechnology Corp AFOLUX LX Series Panel Virus Warning Disabled NOTE Many disk diagnostic programs can cause the above warning message to appear when the program attempts to access the boot sector table If you are running such a program it is recommended that the virus protection function be disabled beforehand Use the Virus Warning option to enable BIOS to monitor the boot sector and partition table of the HDD for any attempted modification If a modification attempt is made the BIOS halts the system and an error message appears If necessary an anti virus program can then be run to locate and remove the virus before any damage is done gt Enabled Activates automatically when the system boots up causing a warning message to appear when anything attempts to access the boot sector or HDD partition table gt Disabled Default warning message appears when there is an attempt to access the boot sector or HDD partition table CPU Internal Cache Enabled
37. 4 rack mounting clamps for AFL 07A LX AFL 08A LX and 6 rack mounting clamps for AFL 12A LX Step 3 Tighten the screws that pass through the rack mounting clamps until the plastic caps at the front of all the screws are firmly secured to the bracket Figure 3 19 Rack Cabinet Bracket L Clamp Figure 3 19 Secure the Rack Cabinet Bracket AFL 12A LX Step 4 Slide the flat panel PC with the attached rack cabinet bracket into a rack or cabinet Figure 3 20 gt AFOLUX LX Series Flat Panel PC Figure 3 20 Install into a Rack Cabinet Step 5 Once the flat panel PC with the attached rack cabinet bracket has been properly inserted into the rack or cabinet secure the front of the rack cabinet bracket to the front of the rack or cabinet Figure 3 20 3 8 Bottom Panel Connectors 3 8 1 Ethernet Connection The two rear panel RJ 45 connectors can be connected to an external LAN and provide Internet connectivity to the flat panel PC 3 8 2 Serial Ports The panel PC provides two RS 232 serial ports on the bottom panel The serial ports facilitate the connection to serial devices or a communications network e g terminal console 3 8 3 USB Connection 1 RIechnology Corp AFOLUX LX Series Flat Panel PC The rear panel USB connectors provide easier and quicker access to external USB devices The rear panel USB
38. AFL 07A LX AFL 08A LX AFL 12A LX Model PANJIT 1070404C PANJIT 1084403B PANJIT 1121505B Type Analog Resistive Type Touch Panel Wire Type 4 wire 4 wire 5 wire Viewing Area mm 154 90 x 93 94 130 75 x 173 38 188 0 x 250 0 Active Area mm 152 40 x 91 44 127 78 x 170 38 185 0 x 246 0 Total Transmission 78 Maximum Voltage DC7V Connector Type FPC Operating Temperature 10 C 60 C 10 C 50 C Operating Humidity 20 90 RH Storage Temperature 20 C 70 C Storage Humidity 20 90 RH Dimensions 165 0 x 104 0 x 1 4 145 53 x 188 04 x 2 1 204 x 268 x 2 1 Table 1 5 Touch Panel Specifications AFOLUX LX Series Flat Panel PC 1 5 Dimensions 1 5 1 AFL 07A LX Dimensions The dimensions of the AFL 07A LX flat panel PC are shown in Figure 1 6 below 2135 55 128 58 20 Figure 1 6 AFL 07A LX Dimensions units in mm Page 12 AFOLUX LX Series Panel PC RIechnology Corp 1 5 2 AFL 08A LX Dimensions The dimensions of the AFL 08A LX flat panel PC are shown in Figure 1 7 below 219 6 9 255 86 170 58 127 78 Figure 1 7 AFL 08A LX Dimensions units in mm 6 14 AFOLUX LX Series Flat Panel PC 1 5 3 AFL 12A LX Dimensions The dimensions of the AFL
39. C _ IE gt AFOLUX LX Series Flat Panel PC Figure 3 7 AFL 12A LX HDD Bracket Retention Screws Step 7 Attach the HDD brackets to the HDD To do this align the four retention screw holes in the both sides of the HDD bracket with the retention screw holes on the sides of the HDD Insert four retention screws into the HDD bracket Figure 3 8 Figure 3 8 AF 12A LX HDD Retention Screws Step 8 Step 9 Step 10 Step 11 Step 12 Connect the IDE cable to the rear of HDD Install the HDD into the AF 12A LX by aligning the retention screw holes in the HDD brackets with the retention screw holes on the chassis Insert the four retention screws Re connect the power switch cable to the motherboard Replace the aluminum back cover to the chassis Replace the plastic back cover 3 7 Mounting the System WARNING When mounting the flat panel PC onto an arm onto the wall or onto a panel it is better to have more than one person to help with the installation to make sure the panel PC does not fall down and get damaged AFOLUX LX Series Flat Panel PC 1 RIechnology Corp The four methods of mounting the AFOLUX LX are listed below Wall mounting Panel mounting Arm mounting Rack mounting The four mounting methods are described below 3 7 1 Wall Mounting To mount the flat panel PC onto the wall please follow the steps below
40. Enabled AFOLUX LX Series Flat Panel PC If the drive connected to the system supports block mode use the IDE HDD Block Mode option to enable the system to detect the optimal number of block read writes per sector the system IDE drive can support Block mode is also called block transfer multiple commands or multiple sector read write gt Disabled Block mode is not supported gt Enabled Default Block mode is supported Onboard Serial Port 1 3F8 IRQ4 Use the Onboard Serial Port 1 option to select the address and IRQ for the onboard serial port 1 The serial port can be disabled or the address and the be automatically selected by the BIOS The Onboard Serial Port 1 options are m Disabled m 3F8 IRQ4 Default m 2F8 IRQ3 m 3E8 IRQ4 m 2E8 IRQ3 m Auto Onboard Serial Port 2 2F8 IRQ3 Use the Onboard Serial Port 2 option to select the I O address and for the onboard serial port 2 The serial port can be disabled or the I O address and the IRQ can be automatically selected by the BIOS The Onboard Serial Port 2 options are m Disabled m 3F8 IRQ4 m 2F8 IRQ3 Default m 3E8 IRQ4 m 2E8 IRQ3 m Auto AFOLUX LX Series Flat Panel PC _ 0 RITechnology Corp Onboard Parallel Port 378 IRQ7 Use the Onboard Parallel Port option to specify a logical LPT port address and corresponding interrupt for the physical parallel port The Onboard Parallel Port
41. Four Hexagonal Pillars on the Bottom Panel AFL 08A LX Step 3 Detach the tapes securing the wireless module cables on the chassis Figure 4 5 Step 4 Carefully cross the wireless module cables over the screw holes of the aluminum cover Figure 4 5 Corp Wireless Module Cables Figure 4 5 Wireless Module Cables Step 5 Push the external interface connector apart from the aluminum cover and lift the cover Figure 4 6 Figure 4 6 The Internal Aluminum Cover Removal Step 6 Disconnect the power switch cable Figure 4 7 from the motherboard and remove the aluminum cover _ IE gt Figure 4 7 Power Switch Cable 4 3 3 AFL 12A LX Internal Aluminum Cover Removal Step 1 Remove the eight retention screws securing the internal aluminum cover Figure 4 8 Figure 4 8 AFL 12A LX Aluminum Back Cover Retention Screws Step 2 Remove the four hexagonal pillars on the bottom panel Figure 4 9 3 4 AFOLUX LX Series Flat Panel PC mme IEI jTechmnology Corp Push the external interface connector apart from the aluminum cover and lift the aluminum cover off the AFL 12A L X Disconnect the power switch cable from the motherboard and remove the aluminum cover 4 4 Memory Module Replacement The flat panel PC is preinstalled with a 256MB 512MB DDR memory module If the memory module i
42. IDE Slave IDE devices are detected and shown in the Standard CMOS Features menu m IDE Primary Master m IDE Primary Slave Flat Panel PC the day month _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC IDE device configurations are changed or set in the IDE Configuration menu If an IDE device is detected and one of the above listed two BIOS configuration options is selected the IDE configuration options shown in Section 5 2 1 appear Halt All But Keyboard Use the Halt On option to specify what errors detected during the power up process stop the system gt All Errors Whenever BIOS detects a non fatal error the system is stopped and the user prompted gt No Errors The system boot is not stopped for any errors that may be detected gt All But Keyboard Default system boot does not stop for a keyboard error it stops for all other errors Base Memory The Base Memory is NOT user configurable The POST determines the amount of base or conventional memory installed in the system The value of the base memory is typically 512K for systems with 512K memory installed or 640K for systems with 640K or more memory installed Extended Memory The Extended Memory is NOT user configurable The BIOS determines how much extended memory is present during the POST This is the amount of memory above 1MB located in the memory address map of the CPU Total Me
43. L is a registered trademark of INTEL Corporation Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of their respective owners Page iii _ AFOLUX LX Series Flat Panel Packing List If of the components listed in the checklist below are missing please do not proceed with the installation Contact the IEI reseller or vendor you purchased the AFOLUX LX series from or contact an IEI sales representative directly To contact an IEI sales representative please send an email to sales iei com tw The items listed below should all be included in the AFOLUX LX series package m 1x Power cord m 1x Power adapter m 1x Touch pen m 1x User Manual and driver CD m 1x Panel mounting kit optional 1 x Wall mounting kit optional m 1x 128 CompactFlash card with Windows 5 0 pre installed optional m 1x 1GB CompactFlash card with Windows XPE pre installed optional Images of the above items are shown in Chapter 3 on page 26 Page iv AFOLUX LX Series Flat Panel PC mme RITechnology Corp Precautions SAFETY PRECAUTIONS 1 Prior to installing moving and modifying the panel PC make sure that the unit s power is turned off and the power cord is disconnected Do not apply voltage levels that exceed the specified voltage ra
44. MA option is only available if the Parallel Port Mode option is set to ECP mode Use the ECP Mode Use DMA option to specify the DMA channel the parallel port must use in the ECP mode gt 1 The parallel port uses DMA Channel 1 in ECP mode gt 3 Default parallel port uses DMA Channel 3 in ECP mode Onboard Serial Port 3 3E8 Use the Onboard Serial Port 3 option to select the I O address for the onboard serial port 3 The serial port can be disabled or the I O address can be automatically selected by the BIOS The Onboard Serial Port 3 options are m Disabled m 3F8 m 2F8 m 3E8 Default m 2E8 Serial Port Use IRQ IRQ5 Use the Serial Port 3 Use IRQ option to select the IRQ for the onboard serial port 3 The serial port can be disabled or the IRQ can be automatically selected by the BIOS The Serial Port 3 Use IRQ options are Page 80 _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC Disabled m IRQ5 Default m IRQ7 Onboard Serial Port 4 2E8 Use the Onboard Serial Port 4 option to select the I O address for the onboard serial port 4 The serial port can be disabled or the I O address can be automatically selected by the BIOS The Onboard Serial Port 4 options are m Disabled m 3F8 m 2F8 m 3E8 m 2E8 Default Serial Port 4 Use IRQ IRQ7 Use the Serial Port 4 Use IRQ option to select the IRQ for the onboard serial port 4 The serial port can
45. Resistive type touch screen Wireless LAN module Power switch Preinstalled OEM customizations may include the following Different DDR memory module Hard disk drive AFL 12A LX model only Installation of some of the components are described in the following sections 3 3 Installation and Configuration Steps The following installation steps must be followed Page 24 1 2 3 4 5 6 AFOLUX Series Flat Panel PC _ 0 RITechnology Corp Unpack the flat panel PC Install CF card Install HDD AFL 12A LX model only Mount the flat panel PC Connect peripheral devices to the bottom panel of the flat panel PC Configure the system 3 4 Unpacking To unpack the flat panel PC follow the steps below WARNING The front side LCD screen has a protective plastic cover stuck to the screen Only remove the plastic cover after the flat panel PC has been properly installed This ensures the screen is protected during the installation process Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Use box cutters a knife or a sharp pair of scissors that seals the top side of the external second box Open the external second box Use box cutters a knife or a sharp pair of scissors that seals the top side of the internal first box Lift the monitor out of the boxes Remove both polystyrene ends one from each s
46. Serial Port 3 Use IRQ5 nain ura Guarani suae 80 Onboard Serial Port 4 2 8 22 2 2 122 81 Serial Port 4 Use IRQ IRQT nec ntn neuen 81 BIOS Menu 7 Power Management Setup eese nnne 82 ACPI Function 82 ACPI Suspend 51 83 Power Management 22 24222 22 222 83 x Standby Mode 83 x Suspend Mode Disabled sees enne 84 Modem Use of 85 Wake on Lan Control 2 22 1222222 85 Soft Off by PWR BTTN Instant Off eere nnns 85 Power On by Alarm 86 Time hih mm ss AIaETm eee eene eene no nuoc 86 IRQ Wakeup Events Press 22 2 22 2 2 2 86 BIOS Menu 8 IRQ Wakeup 87 BIOS Menu 9 PnP PCI Configurations 88 PNP OS Installed No 5 88 Init Display First Onboard
47. Specifications The AFOLUX LX series come with a TFT LCD monitor at the front of the flat panel PC see Figure 1 1 The specifications for the LCD monitor are shown in Table 1 4 below AFOLUX LX Series Flat Panel SPECIFICATION AFL 07A LX AFL 08A LX AFL 12A LX Model DATA IMAGE AUO G084SN03 CMO G121X1 L01 FG070050DNCWAGO01 Size 7 8 4 12 1 Resolution 800 x 480 VGA 800x600 SVGA 1024 x 768 XGA Active Area mm 152 4 x 91 44 170 4 x 127 8 245 76 x 184 32 Pixel Pitch mm 0 1905 x 0 1905 0 213 x 0 213 0 240 x 0 240 LCD Color Native 262K colors Native 262K colors Native 262K colors View Angel H V 140 100 130 110 160 160 Brightness cd m 220 220 450 Contrast Ratio 400 1 500 1 700 1 Response Time ms 12 18 Tf 10 Tr 25 Tf 6 17 Tf Power Consumption W 22 3 3 4 Supply Voltage V 3 3 3 3 3 3 Backlight 1 CCFL 1 CCFL 2 CCFL Backlight MTBF hrs 30000 20000 50000 Outline Dimensions mm 165 0 x 104 0 x 5 5 203 0 x 142 5 x 5 7 260 x 204 x 122 Table 1 4 TFT LCD Monitor Specifications AFOLUX LX Series Flat Panel PC 1 4 5 Touch Screen Specifications _ 0 RITechnology Corp The AFOLUX LX series come with an analog resistive type touch panel Table 1 5 lists the touch panel specifications SPECIFICATION
48. UX LX Series Flat Panel PC _ 0 RITechnology Corp Feature AMD Geode LX Processor Color Depth 8 16 32 bpp A RGB 4 and 8 bit indexed ROPs 256 2 src dest and pattern BLT Buffers FIFOs in Graphics Processor BLT Splitting Managed by hardware Video Synchronized BLT Vector Throttle by VBLANK Bresenham Lines Yes Patterned stippled Lines Yes Screen to Screen BLT Yes Screen to Screen BLT with mono expansion Yes Memory to Screen BLT Yes throttled rep movs writes Accelerated Text No Pattern Size Mono 8x8 pixels Pattern Size Color 8x8 pixels Monochrome Pattern Yes with inversion Dithered Pattern 4 color No Color Pattern 8 16 32 bpp Transparent Pattern Monochrome Solid Fill Yes Pattern Fill Yes Transparent Source Monochrome Color Key Source Transparency Y with mask Variable Source Stride Yes Variable Destination Stride Yes Destination Write Bursting Yes Selectable BLT Direction Vertical and Horizontal Alpha BLT Yes constant a or sep a channel VGA Support Decodes VGA Register Pipeline Depth Unlimited Accelerated Rotation BLT 8 16 32 bpp Color Depth Conversion 5 6 5 1 5 5 5 4 4 4 4 8 8 8 8 Table 2 1 Geode LX Graphics Features _ IE IT echnology Gorp AFOLUX LX Series Flat Panel PC 2 5 Ethernet Controlle
49. Use the CPU Internal Cache option to enable or disable the internal CPU cache gt Disabled The internal CPU cache is disabled gt Enabled Default internal CPU cache is enabled Quick Power On Self Test Enabled Use the Quick Power On Self Test option to speed up the POST after the computer is turned on If enabled BIOS shortens or skips some POST check items _ IE AFOLUX LX Series Flat Panel gt Disabled Normal POST occurs after the computer is turned on gt Enabled Default Quick POST occurs after the computer is turned on Boot From LAN Control Disabled Use the BOOT From LAN Control option to enable the system to be booted from a remote system gt Disabled Default The system cannot be booted from a remote system through the LAN gt Enabled The system can be booted from a remote system through the LAN Boot Device Use the Boot Device options to select the order of the devices the system boots from There are three boot device configuration options m First Boot Device Default SCSI m Second Boot Device Default HDD 0 m Third Boot Device Default CDROM Using the default values the system first looks for a SCSI drive to boot from If it cannot find a SCSI drive it boots from a HDD If both The SCSI drive and the HDD are unavailable the system boots from a CD ROM Boot Device configuration options are m 15120 m 0
50. amaged by electrostatic discharge ESD Before working with the internal components make sure all the anti static precautions described earlier have been observed To replace any of the following components I Corp AFOLUX LX Series Flat Panel PC m Motherboard m DDR memory module m Wireless LAN module m Inverter The internal aluminum back cover of the AFOLUX LX series must be removed To remove the aluminum back cover please follow the steps below 4 3 1 AFL 07A LX Internal Aluminum Cover Removal Step 1 Remove the four retention screws securing the internal aluminum cover Figure 4 1 Figure 4 1 AFL 07A LX Aluminum Back Cover Retention Screws Step 2 Remove the four hexagonal pillars on the bottom panel Figure 4 2 Figure 4 2 Four Hexagonal Pillars on the Bottom Panel AFL 07A LX Step 3 Push the external interface connector apart from the aluminum cover and lift the aluminum cover off the AFL 07A LX Step 4 Disconnect the power switch cable from the motherboard and remove the aluminum cover gt 4 3 2 AFL 08A LX Internal Aluminum Cover Removal AFOLUX LX Series Flat Panel PC Step 1 Remove the four retention screws Figure 4 3 Figure 4 3 AFL 08A LX Aluminum Back Cover Retention Screws Step 2 Remove the four hexagonal pillars on the bottom panel Figure 4 4 Figure 4 4
51. be disabled or the IRQ can be automatically selected by the BIOS The Serial Port 4 Use IRQ options are m IRQ5 wm Default 5 6 Power Management Setup Use the Power Management Setup menu BIOS Menu 7 to set the BIOS power management and saving features Flat Panel AFOLUX LX Series Phoenix Awa 03 CMOS Setup Utility Power M Function Enabled Item Help ACP SUS pend Lupe US nagement 028 Menu Level gt Pre 8 limers Standbu Mode Disabled 1 231 Disabled CInstant Off1 Disabled v Press Enter Help PD Ualue F10 Defaults 11 Defaults Previous Values BIOS Menu 7 Power Management Setup ACPI Function Enabled Use the ACPI Function to enable the ACPI Advanced Configuration and Power Interface function Disabled ACPI function disabled Enabled Default ACPI function enabled AFOLUX LX Series Flat Panel PC _ 0 RITechnology Corp ACPI Suspend S1 POS Use the ACPI Suspend Type when not being used si POS Default s3 STR 81883 Power Management ACPI Use the Power Management system Disabled gt Legacy apm Default x Standby Mode Disabled BIOS option to spe
52. chipset configuration features m Integrated Peripherals Changes the settings for integrated peripherals Power Management Setup Configures power saving options m PnP PCI Configurations Changes the advanced PCI PnP settings Health Status Monitors essential system parameters The following user configurable options are also available in BIOS Menu 1 Load Fail Safe Defaults Use the Load Fail Safe Defaults option to load failsafe default values for each BIOS parameter the setup menus Press F6 for this operation any page Load Optimized Defaults Use the Load Optimized Defaults option to load optimal default values for each BIOS parameter the setup menus Press F7 for this operation on any page Set Supervisor Password Use the Set Supervisor Password option to set the supervisor password By default no supervisor password is set To install a supervisor password select this field and enter the password After this option is selected a red dialogue box appears with Enter Password Type the password and press ENTER Retype the original password into the Confirm Password dialogue box and press ENTER To disable the password simply Page 58 _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC press ENTER in the Enter Password dialogue box then press any key in the Password Disabled dialogue box Set User Password Use the Set Use
53. cify the sleep state the system enters System appears off The CPU is stopped RAM is refreshed the system is running in a low power mode System appears off The CPU has no power RAM is in slow refresh the power supply is in a reduced power mode Both suspend modes are implemented option to set the power management type used by the All power management options are turned off The only user configurable options are the power button and alarm settings Standby and suspend modes can be set Advanced power management APM is activated Advanced Configuration and Power Interface ACPI is activated The Standby Mode option can only be selected if the Power Management option is set to Legacy The Standby Mode specifies the amount of time the system can be inactive before the system enters standby mode The Standby Mode options are _ m Disabled Default AFOLUX LX Series Flat Panel PC m 1Sec m 5Sec m 10 Sec m 15 Sec m 30 Sec m 45 Sec m 1Min m 5Min 10 Min m 15 Min m 30 Min m 45 Min m 60 Min 90 Min 120 Min Suspend Mode Disabled The Suspend Mode option can only be selected if the Power Management option is set to Legacy The Suspend Mode specifies the amount of time the system can be inactive before the system enters suspend mode The Suspend Mode options are Disabled Default m 15 m 5Sec m 10 Sec 15 Sec 30
54. ease read the following license agreement carefully lt Software License Copyright Salt International Corp All rights reserved PenMount Utilities drivers include DOS Windows 3 11 Windows 95 Windows 98 Windows ME Windows NT Windows 2000 Windows Windows CE Linux and drivers copy modify or translate is prohibited except with Salt s written consents license PenMount Utilities drivers contact Salt Intemational Corp Email salt salt com tw Taccept the terms in the license agreement Ido not accept the terms in the license agreement Installshield lt Back 3 Step 6 Click the Installshield Wizard is ready to install the program Figure C 4 Page 102 _ RITechnology Corp AFOLUX LX Series Flat Panel PC ig PenMount DMC9000 InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation S Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield a Figure C 4 Ready to Install the Program Step 7 Click INSTALL to continue The Installing PenMount DMC9000 screen appears as the program is installed Figure C 5 ie PenMount DMC9000 InstallShield Wizard Installing PenMount DMC9000 The pr
55. emical vapors The panel PC is actively cooled In no circumstances should the panel PC _ IE AFOLUX LX Series Flat Panel operate with the openings obstructed by foreign objects However the ambient temperature of the installation site should be observed and controlled to avoid overheating the panel PC Condensation might form inside the panel PC chassis if exposed to sudden changes in temperature Carefully route the power cord so that people cannot step on it Do not place anything over the power cord If the equipment should be left unused for an extended period of time disconnect it from the power source to avoid damage by transient over voltage If any of the following situations arises get the equipment checked by service personnel O The power cord or plug is damaged O Liquid has penetrated into the equipment The equipment has been exposed to moisture O The equipment does not work properly or the user cannot get it to work according to the user manual equipment has been dropped and damaged O The equipment shows obvious signs of breakage WARNING Any changes or modifications made to the equipment that are not expressly approved by the relevant standards could void the authority to operate the equipment MAINTENANCE AND CLEANING Note the following precautions before beginning to clean the Panel PC When cleaning any single part o
56. ent page menu items Optimized defaults for the current page menu items F10 Save changes and Exit BIOS Table 5 1 BIOS Navigation Keys 5 1 3 Getting Help When F1 is pressed a small help window describing the appropriate keys to use and the possible selections for the highlighted item appears To exit the Help Window press Esc or the F1 key again 5 1 4 Main BIOS Menu Once the BIOS opens the main menu BIOS Menu 1 appears Phoenix fiuardBIOS 5 Setup Utilitu ali gt Standard CMOS Features Load Fail Safe Defaults gt Advanced BIOS Features Load Optimized Defaults gt Advanced Chipset Features Set Supervisor Password gt Integrated Peripherals Set User Password gt Power Management Setup Save amp Exit Setup gt PnP PCI Conf igurations Exit Without Saving gt PC Health Status m Esc Quit 1 lt Select Item F10 Save amp Exit Time Date Hard Disk Type 2 BIOS Menu 1 Award BIOS CMOS Setup Utility _ IE AFOLUX LX Series Flat Panel The following sections will completely describe the menus listed below and the configuration options available to users The following menu options are seen in BIOS Menu 1 m Standard CMOS Features Changes the basic system configuration wm Advanced BIOS Features Changes the advanced system settings m Advanced Chipset Features Changes the
57. es Page 70 _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC CPU Frequency 500MHz Use the CPU Frequency option to set the CPU frequency The CPU Frequency options are m Auto 200 2 m 333MHz wm 400MHz m 433MHz 500MHz Default Memory Frequency Auto Use the Memory Frequency option to set the frequency of the installed DRAM modules The Memory Frequency options are m Auto Default m 100 2 m 133MHz 166 2 200 2 gt CAS Latency Auto Use the CAS Latency Time option to set the Column Address Strobe CAS delay time The CAS Latency Time options are m Auto Default m 1 5 nanoseconds m 2 0 nanoseconds 2 5 nanoseconds m 3 0 nanoseconds m 3 5 nanoseconds Interleave Select LOI Use the Interleave Select option to specify how the cache memory is interleaved _ IE AFOLUX LX Series Flat Panel PC gt Default Low order interleaving LOI of memory occurs gt High order interleaving of memory occurs Video Memory Size 8M Use the Video Memory Size option to determine how much memory is allocated to the video graphics device The Video Memory Size options are m None wm 8M Default m 16M m 32M m 64M m 128M 254M Output Display Panel amp CRT Use the Output Display configuration to specify the display devices the system is connec
58. g clamps for AFL 12A LX Step 5 Tighten the screws that pass through the panel mounting clamps until the plastic caps at the front of all the screws are firmly secured to the panel Figure 3 15 AFOLUX LX Series Flat Panel PC Screen Figure 3 15 Tighten Panel Mounting Clamp Screws AFL 12A LX 3 7 3 Arm Mounting The AFOLUX LX series is VESA Video Electronics Standards Association compliant and can be mounted on an arm with a 75mm interface pad To mount the AFOLUX LX series on an arm please follow the steps below Step 1 The arm is a separately purchased item Please correctly mount the arm onto the surface it uses as a base To do this refer to the installation documentation that came with the mounting arm When purchasing arm please ensure that it is VESA compliant and that the arm has a 75mm interface pad If the mounting arm is not VESA compliant it cannot be used to support the AFOLUX LX series flat panel PC The AFL 12A LX also supports VESA MIS D 100 Sa cS SS BESTA gt e ELILE CUR 73 AFOLUX LX Series Flat Panel PC Step 2 Once the mounting arm has been firmly attached to the surface lift the flat panel PC onto the interface pad of the mounting arm Step 3 Align the retention screw holes on the mounting arm interface with those in the flat panel PC The AFL 07A LX AFL 07A LX arm mou
59. ide Pull the plastic cover off the flat panel PC Make sure all the components listed in the packing list are present _ IE IT echnology Gorp 3 4 1 Pac king List AFOLUX LX Series Flat Panel PC The AFOLUX LX flat panel PC is shipped with the following components Quantity Item Standard 1 Power adapter Power cord User manual CD and driver CD 1 Touch pen Optional 4 6 Panel mounting clamp AFL 12A LX Wall mounting kit CE 5 0 pre installed and SDK 128 CompactFlash card with Windows XPE pre installed 1GB CompactFlash card with Windows If any of these items are missing or damaged contact the distributor or sales representative immediately AFOLUX LX Series Panel PC 6 IEI Corp 3 5 CF Card Installation The AFOLUX LX series has CF Type II slot inside the rear panel To install the CF card follow the instructions below Step 1 Remove the nine retention screws Figure 3 1 and lift the cover off the flat panel PC Figure 3 1 Back Cover Retention Screws Step 2 For AFL 08A LX lift the cover off and pull down the cover a bit to make it possible to lift the cover further more after removing the nine retention screws Figure 3 2 Push the power switch while lifting the back cover More strength is required to separate the cover from
60. is denied if the correct password is not entered at the prompt To disable security select the password setting in the Main Menu When asked to enter a password don t type anything press ENTER and the security is disabled Once the security is disabled the system boots and Setup can be accessed OS Select For DRAM gt 64MB Non OS2 Use the OS Select For DRAM gt 64MB option to specify the operating system gt Non OS2 Default Select this option when using the 05 2 operating system gt 052 Specifies the operating system used as 05 2 Small Logo EPA Show Disabled AFOLUX LX Series Flat Panel PC Use the Small Logo EPA Show option to specify if the Environmental Protection Agency EPA logo appears during the system boot up process If enabled the boot up process may be delayed gt Disabled Default EPA logo does not appear during boot up gt Enabled EPA logo appears during boot up 5 4 Advanced Chipset Features Use the Advanced Chipset Features menu BIOS Menu 4 to change chipset configuration options Phoenix fiwar Advance n 500 Miz Item Help uto 1 Menu Level ELOI Output display Panel amp CRTI gt Flat Panel Configuration Press Enter nboard fiudio Enabled BIOS Menu 4 Advanced Chipset Featur
61. mory The Total Memory is NOT user configurable _ IE 5 2 1 IDE Primary Master Slave AFOLUX LX Series Flat Panel PC Use the IDE Primary Master Slave menu to set or change the master slave IDE configurations IDE HDD Auto Detection Press Enter Use the IDE HDD Auto Detection option to enable BIOS to automatically detect the IDE settings Select IDE HDD Auto Detection and press ENTER BIOS automatically detects the HDD type Do not set this option manually IDE Primary Master Auto Use the IDE Primary Master option to activate or deactivate the following drive channels m Channel 0 Master m Channel 0 Slave m Channel 1 Master m Channel 1 Slave gt If no drives are connected to the IDE channel select this option Once this IDE channel becomes inaccessible and any drives attached to it are undetected gt Default Setting this option allows the device to be automatically detected by the BIOS gt Manual Selecting this option allows manual configuration of the device on the IDE channel in BIOS Access Mode Auto The Access Mode option can only be configured if the BIOS configuration option is set to either Manual or Auto Use the Access Mode option to determine the hard disk BIOS AFOLUX LX Series Flat Panel PC _ 0 RITechnology Corp translation modes Most systems now use hard drives with large capacitie
62. n O Support for High Definition HD and Standard Definition SD standards O Support 1920x1440 in CRT mode and 1600x1200 in TFT mode m VESA 1 1 and 2 0 VIP VDA support m 0 13 micron process m 481 terminal PBGA Plastic Ball Grid Array with internal heatspreader AFOLUX LX Series Panel PC _ 0 RITechnology Corp 2 2 2 AMD Geode LX 800 500MHz Power Management The power management for the 500 2 AMD Geode LX 800 is listed below 1 8W Typical 3 9W TDP 500MHz GeodeLink active hardware power management Hardware support for standard ACPI software power management companion SUSP SUSPA power controls Lower power Wakeup on SMI INTR 2 3 System Chipset The AFLMB LX800 motherboardl has a preinstalled AMD Geode CS5536 system chipset The system chipset features are listed below GeodeLink Interface Unit 64 bit 66MHz operation O PCIVSM Virtual System Module that makes the interface transparent to applications software and BIOS O Programmable routing descriptors use and activity monitors and SSMI Synchronous System Management Interrupt ATA 6 Controller 100 MB second IDE Controller in UDMA mode per the ATA 6 specification 5V interface Flash Interface O Multiplexed with IDE interface Connects to an array of industry standard NAND Flash and or NOR Flash USB Controller 4 USB ports two internal and two external O Supports both USB 1 1 and USB 2 0
63. ndows CE Driver PenMount 000 QNX Driver PenMount Other Driver PenMount User s Manual English Version PDF documents PenMount User s Manual Korea Version PDF documents Download Acrobat Reader Download PenMount New Driver SALT Website Contact Us Browse this CDROM Figure C 1 Driver CD Pop Up Screen Step 3 Select the operating system installed on the system from the menu on the screen The following description is for driver installation using Windows 2000 OS If a different OS is installed please refer to the driver user manual for the relevant OS The driver user manuals can be accessed by selecting User Manual from the menu on the left side of the Driver CD Pop Up Screen Page 101 AFOLUX LX Series Flat Panel Step 4 Once the OS system is selected a welcome screen appears Figure C 2 To continue the installation process click NEXT PenMount DMC9000 InstallShield x Welcome to the InstallShield Wizard for PenMount DMC9000 The InstallShield R Wizard will install PenMount DMC9000 on your computer To continue click Next Back Cancel Figure C 2 Welcome Screen Step 5 The license agreement shown in Figure C 3 appears Agree to the license by selecting I accept the terms the license agreement ig PenMount DMC9000 InstallShield Wi License Agreement Pl
64. nge Doing so may cause fire or an electrical shock Electric shock can occur if the panel is opened Do not drop or insert any objects into the ventilation openings of the panel PC Only qualified engineers from certified system integrators or VARs are allowed to make necessary functional modifications to the panel adding touch screen IEI offers the customization service on a pre order basis If considerable amount of dust water or fluids entered the panel PC turn off the power supply immediately unplug the power cord and contact the vendor Explosions may occur with installations in environments where flammable gases are present Fault tolerant and failsafe designs should be implemented with the use of the series models on transportation vehicles ships safety security devices or medical devices not related to life support functionalities Users integrators should take the responsibility for implementations with adequate levels of reliability and safety Preventive designs should be implemented so as to avoid the communications faults between the panel PC and the PC workstation terminals that controls it HANDLING PRECAUTIONS 1 a oo N Do not drop the panel PC against a hard surface Doing so may damage the display Do not strike or exert excessive force onto the touch panel Touching the touch panel using a sharp object may damage the LCD panel Avoid environments exposed to direct sunlight dust or ch
65. nt retention screw holes are shown in Figure 3 16 and the AFL 12A LX are shown in Figure 3 17 75mm 75mm Figure 3 16 AFL 07A LX AFL 08A LX Arm Mounting Retention Screw Holes _ IE gt AFOLUX LX Series Flat Panel PC Figure 3 17 AFL 12A LX Arm Mounting Retention Screw Holes Step 4 Secure the flat panel PC to the interface pad by inserting four retention screws through the bottom of the mounting arm interface pad and into the flat panel PC 3 7 4 Cabinet and Rack Installation The AFL xxA LX series flat panel PC can be installed into a cabinet or rack The installation procedures are similar to the panel mounting installation To do this please follow the steps below NOTE When purchasing the cabinet rack installation bracket make sure it is compatible with both the AFL xxA LX series flat panel PC and the rack cabinet into which the AFL xxA LX series is installed Step 1 Slide the rear chassis of the AFL xxA LX series flat panel PC through the rack cabinet bracket until the aluminum frame is flush against the front of the bracket Figure 3 18 Rack Cabinet Bracket Figure 3 18 The Rack Cabinet Bracket Step 2 Insert the rack mounting clamps into the pre formed holes along the edges of Page 38 RIechnology Corp AFOLUX LX Series Flat Panel PC the flat panel PC behind the ABS PC plastic frame There are a total of
66. oduction The onboard touch panel controller enables analog resistive touch panels for four wire five wire amp eight wire models The controller directly communicates with the PC system through the touch panel communications interface The controller design is superior in sensitivity accuracy and friendly operation The touch panel driver emulates the left mouse button and the right mouse button functions The touch panel driver supports the following operating systems Microsoft Windows versions Microsoft Windows 95 Microsoft Windows 98 Microsoft Windows ME Microsoft Windows 2000 Microsoft Windows NT Microsoft Windows XP Microsoft Windows 3 1 m Microsoft Windows 0 0 m Linux m QNX m DOS Driver installation is described below Page 100 16 RITechnology Corp AFOLUX LX Series Flat Panel PC B 2 2 Driver Installation To install the touch panel software driver please follow the steps below Step 1 Insert the driver CD that came with the AFOLUX series into the CD drive Step 2 Once the CD drive is installed the screen in Figure C 1 appears enMount Driver and Manual CD E Salt International Corp mm PenMount DMC9000 Windows 95 2 1 Driver PenMount 000 Windows 98 Me V3 1 Driver PenMount DMCS000 Windows NT V1 1 Driver PenMount DMCOODO Windows 2000 XP 2003 V5 0 Driver PenMount 00 Windows 2000 XP 2003 5 1 0006 Driver PenMount 00 Wi
67. ogram features you selected are being installed Please wait while the InstallShield Wizard installs PenMount DMC9000 This may take several minutes Status Creating shortcuts InstallShield Figure C 5 Installing PenMount DMC9000 Step 8 The user is then prompted to select to restart the computer now or later Figure C 6 For the settings to take effect the computer must be restarted Click Yes to restart the computer Page 103 _ IE gt AFOLUX LX Series Flat Panel izard X The InstallShield Wizard has successfully installed PenMount DMC9000 Click Finish to exit the wizard We recommend you to reboot your computer to enable all the Functions 24 System must be restarted Would you to reboot now sa 2628 Figure C 6 Reboot the Computer B 2 3 Touch Panel Driver Configuration To configure the touch panel driver options refer to the PenMount user manual located on the driver installation CD Page 104 1 RIechnology Corp AFOLUX LX Series Flat Panel PC Index Page 105 _ IE ABS PC plastic frame 4 39 AC power 6 ACPI power management 20 Active Area iic a adero 10 AMD Geode _ 800
68. onfigurable options m Reserved Memory Base m Reserved Memory Length PCI VGA Palette Snoop Disabled Use the PCI VGA Palette Snoop option to enable the system to determine whether or not some special VGA cards high end hardware MPEG decoders and other similar devices are allowed to look at the palette on the video card so these devices can determine what colors are in use This option is needed very rarely and should be left Disabled unless a video device specifically requires the setting to be enabled upon installation gt Disabled Default Does not allow the graphics devices to examine the VGA Page 90 jm Corp AFOLUX LX Series Flat Panel palette on the graphics card gt Enabled Allows the graphics devices to examine the palette on the graphics card 5 8 PC Health Status The PC Health Status menu BIOS Menu 10 has no user configurable options but shows system operating parameters that are essential to the stable operation of the system eae pore i Enter Sel us Values BIOS Menu 10 PC Health Status The following system parameters are monitored by the PC Health Status menu Voltages The following voltages are monitored m Vcore m VccMem 16 IE IT echnology Gorp AFOLUX LX Series Flat Panel PC m 33V m 12V m m 5 Page 92
69. per 1 2 3 2 3CLOSED means removing the plastic clip from a Jumper jumper The motherboard comes with two jumpers They are listed below RITechnology Corp AFOLUX LX Series Flat Panel PC pin 9 signal select JP3 wm COM1 2 pin 9 signal select JP4 Figure 4 12 Jumper Locations 4 5 1 JP3 COM3 Pin 9 Signal Select Jumper Settings The COM3 pin 9 signal can be selected as 12V 5V or Ring pin 9 is 12V output pin 9 is RI input 9 is 5V output 16 IE IT echnology Gorp AFOLUX LX Series Flat Panel PC Table 4 1 9 Signal Select Jumper Settings _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC 4 5 2 JP4 COM1 and COM2 Pin 9 Signal Select Jumper Settings The COM1 and 2 pin 9 signal can be selected 12V 5V or Ring memes compono _ _ E EE Short 6 8 2 pin 9 is 5V output pin 9 is 12v output 2 pin 9 is 5V output Short 8 10 COM2 pin 9 is RI input Table 4 2 COM1 and 2 Pin 9 Signal Select Jumper Settings AFOLUX LX Series Flat Panel THIS PAGE IS INTENTIONALLY LEFT BLANK Page 54 zz ae lt gt
70. r Password option to set the user password By default no user password is set To install a user password select this field and enter the password After this option is selected a red dialogue box appears with Enter Password Type the password and press ENTER Retype the original password into the Confirm Password dialogue box and press ENTER To disable the password simply press ENTER in the Enter Password dialogue box then press any key in the Password Disabled dialogue box gt Save amp Exit Setup Use the Save amp Exit Setup option to save any configuration changes made and exit the BIOS menus Exit Without Saving Use the Exit Without Saving option to exit the BIOS menus without saving any configuration changes 5 2 Standard CMOS Features Use the Standard CMOS Features BIOS menu BIOS Menu 2 to set basic BIOS configuration options AFOLUX LX Series tup Utility w L Item Help Menu Level Change BIOS Menu 2 Standard CMOS Features Date Day mm dd yyyy Use the Date option to set the system date Time hh mm ss Use the Time option to set the system time gt When entering setup BIOS auto detects the presence of IDE devices The Standard CMOS Features menu shows the status of the auto detected IDE devices The following IDE Master and
71. r Specifications 2 5 1 Overview The Realtek RTL8100C L is a highly integrated and cost effective single chip Fast Ethernet controller It is enhanced with an ACPI Advanced Configuration Power Interface management function for PCI in order to provide efficient power management for advanced operating systems with OSPM Operating System Directed Power Management The RTL8100C L also supports remote wake up including AMD Magic Packet and Microsoft Wake up frame to increase cost efficiency in network maintenance and management It is an ideal solution for notebook motherboard embedded network designs 2 5 2 Features m Integrates Fast Ethernet MAC physical chip and transceiver onto a single chip m 10Mbps and 100Mbps operation Supports 10Mbps and 100Mbps auto negotiation Supports 25MHz Crystal or 25MHz OSC as the internal clock source m Complies with PC99 PC2001 standards Supports ACPI power management m Provides PCI bus master data transfer m Provides PCI memory space or space mapped data transfer m Supports PCI clock speed 16 75MHz 40MHz m Advanced power saving mode m Supports Wake on LAN and remote wake up AMD Magic Packet Link Change and Microsoft Wake up frame Half Full duplex capability Supports Full Duplex Flow Control IEEE 802 3x m Provides interface to 93 46 EEPROM to store resource configuration and ID parameters m Provides PCI clock run pin _ 0
72. r component of the computer please read and understand the details below fully Except for the properly installed front LCD panel never spray or squirt liquids directly onto any computer component To clean the device please rub it with AFOLUX LX Series Flat Panel PC _ 0 RITechnology Corp a piece of dry and soft cloth or a slightly moistened cloth with the exterior casing m The interior of the Panel PC does not require cleaning Keep fluids away from the Panel PC and the interior of it m cautious of the tiny removable components when using a vacuum cleaner to absorb the dirt on the floor m Turn the system off before cleaning up the Panel PC m Never drop any tiny objects through the openings of the Panel PC or get circuit board damp or wet m Be cautious of all kinds of cleaning solvents or chemicals when using it for the sake of cleaning Some individuals may be allergic to the ingredients m Avoid any food drink or cigarette around the Panel PC CLEANING TOOLS Although many companies have created products to help improve the process of cleaning the computer and peripherals users can also use household items to clean their computers and peripherals Below is a list of items to use while cleaning the computer or computer peripherals Please keep in mind that some components in the computer may only be cleaned using a product designed for cleaning that component if this is the case it will be
73. s and therefore either the LBA translation mode or auto mode should be selected gt cus gt LBA gt gt gt Capacity Default Select this mode if the HDD capacity is less than 504MB Select this mode if the HDD capacity is more than 8 4GB This mode is an extended ECHS mode and while it supports HDDs larger than 504MB it is not recommended If you are unsure of what access mode to set select this option The Capacity specification indicates the storage capacity of the HDD installed in the system Cylinder The Cylinder specification indicates how many cylinders tracks are on the HDD installed in the system Head The Head specification indicates how many logical heads are on the HDD installed in the system Precomp The Precomp specification indicates on what track the write precompensation begins Landing Zone AFOLUX LX Series Flat Panel PC The Landing Zone specification indicates where the disk head will park itself after the system powers off Sector The Sector specification indicates how many logical sectors the HDD has been divided into 5 3 Advanced BIOS Features Use the Advanced BIOS Features menu BIOS Menu 3 to configure the CPU and peripheral device configuration options E DOSBox 0 63 Cpu Cycle 2000 Frameskip U Progra Phoenix Awa Advance 53 5051
74. s fail follow the instructions below to replace the memory module Step 1 Step 2 Step 3 Remove the back cover See Section 3 5 above Remove the internal aluminum back cover See Section 4 3 above Locate the DDR memory module on the motherboard of the flat panel PC Figure 4 10 Figure 4 10 SO DIMM Socket Location Step 4 Step 5 Step 6 Remove the DDR memory module by pulling both the spring retainer clips outward from the socket Grasp the DDR memory module by the edges and carefully pull it out of the socket Install the new DDR memory module by pushing it into the socket at an angle Figure 4 11 AFOLUX LX Series Flat Panel Step 7 Gently pull the spring retainer clips of the SO DIMM socket out and push the rear of the DDR memory module down Figure 4 11 Step 8 Release the spring retainer clips on the SO DIMM socket They clip into place and secure the DDR memory module in the socket b Figure 4 11 DDR SO DIMM Module Installation 4 5 Jumper Settings A NOTE A jumper is a metal bridge that is used to PLASTIC CLIP OPEN CLOSED close an electrical circuit It consists of two metal pins and a small metal clip often protected by a plastic cover that slides over the pins to connect them To CLOSE SHORT a jumper means connecting the pins of the jumper with the plastic clip and to OPEN jum
75. sed gt Enabled Default primary IDE channel is used Drive PIO Mode Auto Use the Drive PIO Mode options below to select the Programmed Input Output PIO mode for the following HDDs Page 76 _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC m Master Drive PIO Mode Slave Drive PIO Mode gt Default computer selects the correct mode gt 0 mode 0 selected with maximum transfer rate of 3 3MBps gt Mode 1 mode 1 selected a maximum transfer rate of 5 2MBps gt Mode 2 mode 2 selected maximum transfer rate of 8 3MBps gt Mode 3 mode 3 selected with a maximum transfer rate of 11 1MBps gt 4 mode 4 selected with a maximum transfer rate of 16 6MBps gt IDE UDMA Auto Use the IDE UDMA option below to select the Ultra DMA UDMA mode for the following HDDs m IDE Primary Master UDMA m IDE Primary Slave UDMA Disabled The UDMA for the HDD device is disabled gt Default The computer selects the correct UDMA IDE DMA transfer access Enabled Use the IDE DMA transfer access option to enable or disable DMA support for IDE devices connected to the system gt Disabled All IDE drive DMA transfers are disabled The IDE drives use PIO mode transfers gt Enabled Default All IDE drive DMA transfers are enabled _ IE IT echnology Gorp IDE HDD Block Mode
76. signal to the panel The HSYNC Polarity options are m High wm Low Default VSYNC Polarity Active Low The VGSYNC Polarity Active option can only be configured if the Flat Panel Type option is not set to Auto Use the VGSYNC Polarity Active option to set the polarity of the VSYNC signal to the panel The VGSYNC Polarity Active options are m High wm Low Default SHFCLK Active Period Free Running Use the SHFCLK Active Period option to set the SHFCLK The SHFCLK Active Period options are m Active Only m Free running Default LP Active Period Free Running Use the LP Active Period option to set the LDE MOD signal to the panel The LP Active Period options are m Active Only m Free running Default lechnology Corp 5 5 Integrated Peripherals AFOLUX LX Series Flat Panel PC Use the Integrated Peripherals menu BIOS Menu 6 to change the configuration options for the attached peripheral devices e Item Help Auto Auto Menu Level gt Auto Auto Enabled Enabled 3F8 1RQ41 2F8 1RQ31 ISPP 1 71 131 5 2E81 118071 e Select 7 ious Values BIOS Menu 6 Integrated Peripherals On Chip IDE Channel 1 Enabled Use the On Chip IDE Channel 1 option to specify if the system uses the integrated primary IDE channel or not gt Disabled The primary IDE channel is not u
77. ted in Table 1 1 AFL 07A LX CPU LCD Memory Wireless LAN Touch screen 256 MD9LX800 7 256 DDR Yes Yes WT R 5312MB MDGLX800 512MB ppm Yes Yes AFL 08A LX CPU LCD Memory Wireless Touch screen WT R 256MB LX800 256 DDR Yes Yes WT R 512MB MD9LX800 512MB DDR Yes Yes AFL 12A LX CPU LCD Memory Wireless Touch screen WT R 256MB LX800 121 256 DDR Yes Yes WT R 5312MB LX800 1121 2 DDR Yes Yes Table 1 1 Model Variations 1 1 2 Applications The AFOLUX LX series all in one panel PC is designed for multiple applications Its durability and strength makes it an ideal choice for public access computers Some possible applications include m Vehicle Interior device _ 0 RITechnology Corp AFOLUX LX Series Flat Panel PC O Truck PC O Logistic car PC m General computing PC based testing center Distance learning Industrial applications Plant environment monitoring system Factory automation platform Manufacturing shop flow Equipment and device control m Home and building automation Digital surveillance system E home platform Home control terminal m Self Service Kiosk O Receptionist kiosk in hotel and business premises O Self registration terminal in hospital and airport O Ticket vending machine for transportation use 1 1 3 Standard Features
78. ted to The Output Display options are m Flat Panel m CRT m Panel amp CRT Default Flat Panel Configuration Press Enter Use the Flat Panel Configuration option to open the Flat Panel Configuration menu The Flat Panel Configuration options are shown in Section 5 4 1 OnBoard Audio Enabled Use the OnBoard Audio option to enable or disable the onboard codec gt Disabled The onboard codec is disabled gt Enabled Default onboard codec is detected and enabled 5 4 1 Flat Panel Configuration Use the Flat Panel Configuration menu BIOS Menu 5 to set the configuration settings for the flat panel screen connected to the system Phoenix Aw Flat Item Help 10 0 0 f 3 24 bits 1 ppc Menu Level gt gt iresh hate 50 Hz Du panel or use auto Act ive Low detection requires Period Free running Dungeon board Free ruming BIOS Menu 5 Flat Panel Configuration Flat Panel Type Auto Use the Flat Panel Type option to specify the type of flat panel screen connected to the system gt Specifies the system is connected to TFT display gt vos Specifies the system is connected to an LVDS display gt Auto Default The system detects the display type and the display im Corp AFOLUX LX Series Panel _ IE
79. tention screw of the wall mounting bracket Figure 3 11 Figure 3 11 Secure the Panel PC 3 7 2 Panel Mounting To mount the AFOLUX LX series flat panel PC into a panel please follow the steps below Step 1 Select the position on the panel to mount the flat panel PC Step 2 Cut out a section from the panel that corresponds to the rear panel dimensions _ IE gt AFOLUX LX Series Flat Panel PC of the flat panel PC Take care that the panel section that is cut out is smaller than the overall size of the metal frame that surrounds the flat panel PC but just large enough for the rear panel of the flat panel PC to fit through Figure 3 12 Figure 3 13 and Figure 3 14 Panel 93 44 154 4 Figure 3 12 AFL 07A LX Panel Opening dion de RN Panel 130 84 173 38 1 RIechnology Corp AFOLUX LX Series Flat Panel Figure 3 13 AFL 08A LX Panel Opening 189 49 250 99 LN Figure 3 14 AFL 12A LX Panel Opening Step 3 Slide the flat panel PC through the hole until the aluminum frame is flush against the panel Step 4 Insert the panel mounting clamps into the pre formed holes along the edges of the chassis behind the aluminum frame There are a total of 4 panel mounting clamps for AFL 07A LX AFL 08A LX and 6 panel mountin
80. ther manually configure all the boot and plug and play devices or allow BIOS to configure these devices automatically If BIOS is allowed to configure the devices automatically IRQs DMA and memory base address fields cannot be set manually gt Auto ESCD Default BIOS automatically configures plug and play devices as well as boot devices gt Manually configure the plug and play devices and any other boot devices x IRQ Resources Press Enter The IRQ Resources option can only be selected if the Resources Controlled By option is set to Manual _ IE AFOLUX LX Series Flat Panel The IRQ Resources menu has the following options m 3 assigned to m 4 assigned to m 10 assigned to m 11 assigned to The above options all have the following default options gt PCI Device Default The IRQ is assigned to legacy ISA for devices compliant with the original PC AT bus specification PCI ISA PNP for devices compliant with the Plug and Play standard whether designed for PCI or ISA bus architecture gt Reserved The IRQ is reserved by BIOS Resources Press Enter The Memory Resources menu can only be accessed if the Resources Controlled By option is set to Manual Use Memory Resources to select a base address and the length for the memory area used by a peripheral that requires high memory The menu has two c
81. with values that can be selected Time hh mm ss Alarm After setting the alarm the computer will turn itself on from a suspend state when the alarm goes off IRQ Wakeup Events Press Enter To view the IRQ Wakeup Events options press ENTER OT 10 1 Riechnology Corp AFOLUX LX Series Flat Panel PC Phoenix AwardBIOS CMOS Setup Utility IRQ Wakeup Events Item Help Ualue F10 Save ESC Safe Defaults 0 BIOS Menu 8 IRQ Wakeup Events The following IRQs can be used to generate wake events m ON 2 m IRQ4 COM 1 OFF m 5 2 m IRQ6 Floppy Disk OFF m IRQ7 LPT 1 OFF IRQ8 RTC Alarm OFF m IRQQ IRQ2 OFF 10 Reserved OFF m Reserved OFF m 12 PS 2 Mouse OFF m IRQ13 Coprocessor OFF m IRQ14 Hard Disk OFF m 15 Reserved OFF AFOLUX Series Flat Panel 5 7 PnP PCI Configurations Use the PnP PCI Configurations menu BIOS Menu 9 to set the plug and play and PCI options 1 1 7 7 Item Help E NET Data Disabled Menu Level p Resources Controlled Auto ESCD Select Yes if you are lt IRQ Resources 1 ess Ente using a Plug and Play Memory Resources Press Ente capable operating system
Download Pdf Manuals
Related Search
Related Contents
Modelo 28871 DECT 6.0 Sistema de Teléfono con Contestadora y Samsung 151D User Manual PlugIn Installation Manual l`objet ingrédients mode d`emploi Samsung GT-B7300B manual do usuário(Guia estendido) PS-ECC End User Manual スタンダデ ド作業連絡用無線電話装置保証書 死 Gefen EXT-DVIKVM-241DL User manual Frequently Asked Questions Troubleshooting Copyright © All rights reserved.
Failed to retrieve file