Home
User Manual
Contents
1. REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 Incufridge RS IF 203 Incufridge Specifications Model No Precision Uniformity Display Controller Power Requirements Net Weight Outside Dimensions Inside Dimensions Capacity Temperature Range Warranty Measured 37 C under controlled laboratory conditions Contact Us Mailing address Revolutionary Science 17319 Lake Blvd Shafer MN 55074 USA REVOLUTIONARY SCIENCE 17319 Lake Blvd Shafer MN 55074 Toll Free 800 775 7942 Fax 775 218 7015 E mail support revsci com Website www revsci com REVOLUTIONARY SCIENCE S REVSCI RS IF 203 0 7 C Internal temperature uniformity 1 0 C 3 digits 0 1 C resolution Digital microcomputer 100 240 VAC 12 VDC 50 60 Hz 65 watts 22 Ib 38 8cm wide x 48 3cm deep x 28cm tall 14 5 wide x 19 deep x I 1 tall 31 7cm wide x 31 7cm deep x 19cm tall 12 5 wide x 12 5 deep x 7 5 tall 25L 0 88 cu ft Accurately holds from 5 C to 65 C 2 year repair or replacement Toll Free 800 775 7942 Fax 775 218 7015 E mail su revsci com Web site www revsci com REVOLUTIONARY SCIENCE Incufridge RS IF 203 S REVSCI Registration For your future reference and to expedite answers to your questions please complete the following information Date Purch
2. revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 REVOLUTIONARY SCIENCE Incufridge RS IF 203 S REVSCI User Calibration Instructions Setup Set desired temperature on Incufridge and insert calibrated thermocouple or thermometer closest to the geometric center of the chamber Close door and check accuracy of temperature to 2 hours later If temperature is off by more than 0 5 C record Incufridge display reading and thermometer reading and calibrate accordingly following these three simple steps Press up and down buttons simultaneously Display should read CAL 2 After CAL times out a new number will display This is the calibration off set number Press up arrow if you desire to increase the temperature on the display reading or down arrow if you wish to decrease the temperature on the display 3 Wait for three seconds for the display to return to the temperature reading NOTE Incufridge will maintain adjusted calibration if it is turned off or restarted Calibration may be adjusted anytime Temperature Uniformity The temperature uniformity is most precise at the general geometric center of the chamber Geometric extremes i e within an inch or two from the inside of the door ceiling fan walls etc may be less precise For best results it is recommended to place specimens and samples on the trays and if possible close to the geometric center
3. Instruction Manual for the Revolutionary Science RS IF 203 Incufridge REVOLUTIONARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction Recommended Safeguards Operating Instructions Care and Maintenance Calibration Specifications Contact Us Registration Warranty Warranty Registration Card Checklist Notes and Service Record Troubleshooting REVSCI REVOLUTIONARY SCIENCE o OO Oo NN DD uo A A WY N NOTE This manual contains important information safeguards and operating instructions for the operation of the REVOLUTIONARY SCIENCE model RS IF 203 Incufridge by Alternative Pioneering Research amp Development Inc APR amp D Inc Alternative Pioneering Research and Development Inc REVOLUTIONARY SCIENCE 17319 Lake Blvd Shafer MN 55074 Toll Free 800 775 7942 Fax 775 218 7015 E mail support revsci com Website www revsci com REVOLUTIONARY SCIENCE Incufridge RS IF 203 REV SCI REVSCI Introduction Thank you for purchasing the Revolutionary Science RS IF 203 Incufridge We are confident that when used correctly our Incufridge will provide years of reliable service in your lab classroom or fieldwork We have made every effort to use high quality durable parts to deliver the performance expected of instruments costing 3 to 4 times as much Please let us know what you think of our products positive or negative so we can continu
4. ased Serial Number Model Number Purchased From Full Two Year Warranty Your REVOLUTIONARY SCIENCE RS IF 203 is warranted to be free from defects of material or workmanship under normal use for a period of two years from date of purchase If your RS IF 203 proves to be defective within this warranty period Revolutionary Science will repair or replace your unit at our option This warranty will be void if malfunction is caused by accident misuse or negligence including tampering abuse or damage in transit This warranty excludes any relief for incidental or consequential damages Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights you may also have other rights which may vary from state to state Your RS IF 203 comes with several built in safety features Any attempt to interfere with the operation of these features makes this warranty null and void To validate this warranty be sure to complete and return the Warranty Registration Card found on page 8 REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 REVOLUTIONARY SCIENCE Incufridge RS IF 203 S REVSCI Please fill out this page or a copy of it and send it to the address below to vali
5. date your warranty Warranty Registration Card for the REVOLUTIONARY SCIENCE RS IF 203 Incufridge Please Print Date Purchased Serial Number Purchased From Name of Purchaser C Company O School O Individual Please check one Name of institution Department Address Intended use Where did you hear of our product Comments Mail to Revolutionary Science 17319 Lake Blvd Shafer MN 55074 REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 Incufridge RS IF 203 S REVSCI REVOLUTIONARY SCIENCE Checklist Before packaging material is discarded please make sure all parts are accounted for ___ 2 Shelves ___Incufridge ___ Power supply Notes Service Record etc REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 REVOLUTIONARY SCIENCE Incufridge RS IF 203 S REVSCI Troubleshooting Temperature on the display is higher Incufridge may be in need of calibration See calibration instructions in the than the actual manual Temperature on the display is lower Incufridge may be in need of calibration See calibration instructions in the than the actual manual Display screen does not turn on Power cord may be disconnected Inspect all power supply conditions Power switch may be off Ins
6. e to enhance and improve our products in the future Sincerely yours REVOLUTIONARY SCIENCE OE pe S Ma and REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 REVOLUTIONARY SCIENCE Incufridge RS IF 203 S REVSCI To maximize the use of this Incufridge please complete this short list before using the RS IF 203 Examine carton and packaging for possible damage caused during shipping If damage is present contact carrier at once Failure to do so immediately may release the carrier from any liability of damage 2 Fill out the checklist page 9 of instruction manual If something is missing please contact Revolutionary Science 3 Carefully read the instruction manual 4 Fill out warranty registration card and mail it to Revolutionary Science Recommended Safeguards Never attempt to disassemble or modify the RS IF 203 2 Do not clean any parts with solvents 3 Do not drop 4 Keep door closed for effective temperature stabilization 5 Do not operate on wet surfaces 6 Make sure the power cord is clear of hot surfaces and other hazards We recommend any slack in the cord to be wrapped up and held together with a twisty tie 7 Avoid spills of any kind on or in the unit This may contaminate or corrode the surfaces 8 Do not use around flammables combustible materials or explosives 9 Keep back vent
7. pect power switch in back Fan buzzes during operation Something may be caught in the fan Turn off Incufridge and inspect internal and external fans Carefully remove Temperature stays at ambient and Possible defective components Contact Revolutionary Science does not cool Fan is not operational Possible defective components Contact Revolutionary Science If symptoms persist please contact Revolutionary Science Support Center at support revsci com or call 651 674 3112 REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 REGISTERED FIRM 10
8. properly inserted load your samples making sure to leave adequate space between samples for proper air circulation Avoid placing samples directly on floor of chamber instead use shelf to insure even distribution of temperature 3 CONNECTING THE POWER 100 240V use Insert power supply s barrel plug into backside of unit Insert other end of power supply cord into an outlet designed for 100 240v use Make sure the power supply cord is clear of hot surfaces and other hazards Any slack in the cord should be wrapped up and held together with a twisty tie 4 TO OPERATE THE RS IF 203 After power is connected flip power switch on backside of unit to On position Default display is actual chamber temperature To increase chamber temperature press and hold the arrow button pointed up for 2 seconds To decrease chamber temperature press and hold the arrow button pointed down for 2 seconds To display current set temperature press either button Care and Maintenance Your Incufridge should be cleaned periodically to ensure optimal performance cleanliness and to eliminate contamination Clean your REVOLUTIONARY SCIENCE RS IF 203 only when it is not plugged in Using a soft cloth soaked in water and bleach or mild detergent wipe the inside and outside of the unit Then let air dry or wipe with a dry cloth Be careful not to scratch surfaces with abrasive cleaners or dirty cloths REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support
9. s clear at least two inches in every direction from other equipment and avoid setting unit on soft fluffy surfaces This will allow for effective air convection 10 Do not heat any substances that may release fumes considered to be toxic I I Avoid placing samples directly on floor of chamber instead use shelf to insure even distribution of temperature 12 Like all heating and cooling equipment their efficiency depends upon the external or ambient temperature This product has a maximum efficiency at an ambient temperature of 22 C provided that all other safeguards are met If the ambient temperature increases or decreases the maximum efficiency will decrease Recommended Room and Storage Conditions Do not store your REVOLUTIONARY SCIENCE RS IF 203 in direct sunlight or in dusty or poorly ventilated areas Do not store in a cold or moist room for extended periods of time Never immerse your REVOLUTIONARY SCIENCE RS IF 203 in water REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 REVOLUTIONARY SCIENCE Incufridge RS IF 203 S REVSCI Operating Instructions 1 PLACEMENT Place unit on a stable hard surface away from the edge of the counter and other moving equipment 2 LOADING Open the Incufridge by gently pulling outward away from the unit on the door handle With the door open and shelves
Download Pdf Manuals
Related Search
Related Contents
Samsung 917DFI User Manual OctoPre MkII safety rules OPeratION - Northern Tool + Equipment BATTLEZ ラテラルロッド 取付要領書 TwinControl - Somatec, Nord Asrock H61M 3.2 Network Camera Installation DRAFT UFC 3-400-10N Mechanical Engineering Movicon CE Guide de référence Boite à fauves 1 entrée pour rat Copyright © All rights reserved.