1. ID Innovations Datasheet for PR101 MF 3in1 v3 01 2008 5 01 PR101 MF Reader Write 3 in 1 programmer User Manual D ID Innovations Advanced Digital Reader Technology Better by Design V1 05 Step 3 2007 zs ID Innovations Datasheet for PR101 MF 3in1 v3 01 2008 5 01 Summary The PR101 MF series card Read Write programmer is meant to be used with the Mifare reader IC and is compatible with different types Mifare chips The programmer is connected to a PC through a RS232 interface or a RS232 emulated USB port working independently or cooperating within a system net Specification e Part number PR101 MF 3 in 1 e Read range up to 5cm e Out put to PC RS232 USB e Baud rate 9600 bit s e Case ABS e Frequency 13 56Mhz e Power LxWxH 152x115x53 e Weight 600g e Operating temperature 20 C 75 C e Storage temperature 40 C 85 C CPU STC89c54rd Industry level Main chip Philips CLRC632 Memory 8K Supported chip ISO IEC14443 TypeA Mifare One S50 Mifare One S70 Mifare Ultra Light Mifare Pro Mifare DESFIRE SHC1102 ISO IEC14443 TypeB TRH1064 SR176 SIRX4K AT88SF020 SMARTCARD ISO IEC15693 I CODE SLI Tag it SRF55V02P SRF55V10P Serial number bytes in any block Read write function ID Innovations UART Protocols Command frame 9600 N 8 1 Datasheet for 101 3in1 v3 01
2. Indication 40000 0x22 ICODE SLI TAGit EM4034 0x03 EM4035 S S 8bytes serial number 15015693 Read l code SLI block Tag it ISO14443 TYPE B AT88SF020 B 1 byte block serial number X 0x01 For example Write data 0x58 Ox0E FSSSSSSSSBDDDD 0x00 0x00 block F Indication 0x22 ICODE SLI 0x62 TAGit 0x02 EM4034 0x03 EM4035 S S 8bytes serial number B 1 byte block serial umber DDDD 4 bytes serial number For example 15 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 15015693 Lock data 0x59 0x0A FSSSSSSSSB 0x00 0x00 l code SLI block F Indication Tag it Bit4 1 valid command only for the card ISO14443 in SELECT condition TYPEB Bit5 1 valid command only when UID matched AT88SF020 BIT6 1 TAGit 0 ICODE SLI S S 8bytes serial number B 1 bytes serial number For example 216 ID Innovations EM4035 HW authentication w o 0x60 Datasheet for PR101 MF 3in1 v3 01 2008 5 01 0x01 Selection 1 Super User Key 2 secret key 1 4 secret key 2 8 secret key 3 For example Read UID Ox61 0x01 B B BLOCKNUM 12 For example Read data block 0x62 0x01 B B BLOCKNUM For example Write EM4035 0x63 0x09 BDDDDDDDD B BLOCKNUM DDDDDDDDD write block For example 237 ID Innovations Datasheet for 101 3
3. OxFF OxFF OxFF 0x11 0x22 0x33 0x44 0x00 0x00 Command MFO IC S50 S70 Mult Block Data bulk Reading Ox1A 0x09 BAPPPPPPN B BlockNo S50 0x00 0x3f 570 0 00 0 A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 Bytes Key N Read Block Num warning the password in all sectors should be same Ok 0 Err Other N 16 16 N byte Data For example 0x1A 0x09 0x00 0xFF OxFF OxFF OxFF OxFF OxFF OxOc 0x00 N 16 9 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 MFO IC S50 S70 Halt card 0x1B 0x00 Ok 0 0x00 Command Err Other For example request IDLE 0x1C card For example Sending 0X28 0x08 SAPPPPPP 0x00 0x00 EEPROM key S block number S50 0x00 0x0f A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 bytes key For example send 0X29 0x11 BDDDDDDDDDDDDDDDD 0x00 0x00 EEPROM data B EEPROM No 0x00 0x1f D D EEPROM data For example read EEPROM 0X2A 0x01 B 0x00 0x10 data B EEPROM No 0x00 0x1f For example Desfire 10 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 D D 4 bytes encrypt data Desfire Reset 0x20 0x01 0x41 0x00 N N bytes data command For example ProCom_CMD 0x21 N N byte data 0x00 N N bytes data For example
4. 2008 5 01 VALUE 0x02 0x03 LENGTH 1byte 1 byte 1 byte 1 byte LEN bytes 1 byte 1 byte COMMENT Start 0x00 Oxff When Sent DATA NUM DATA XOR From STX to DATA Frame Frame Device CMD end Address When receive STATUS default 0x01 CMD STAUS DATA LENGTH DATA System Command Link 0x00 0x00 Ok 0 0x00 Err Other For Example 0x00 0x00 0x00 0x00 Reset 0x01 0x00 Ok 0 0x00 Err Other For Example 0x01 0x00 0x00 0x00 ID Innovations System Command Datasheet for 101 3in1 v3 01 2008 5 01 Change 0x02 0x01 B OK 0 0x00 baudrate Baudrate Baudrate value Err other 2400 B 0x00 4800 B 0x01 9600 B 0x02 default 14400 B 0x03 19200 B 0x04 28800 B 0x05 57600 B 0x06 For example 0x02 0x01 0x01 0x00 0x00 Buzzer 0x03 0x04 or ABCD OK 0 0x00 control 0x00 A 0x00 buzzer off Err other 0x01 buzzer 0x02 buzzer on BCD 10 ms BCD When A 2 the time is given by the value BCD For example if the time value is 123 then B 0x01 C 0x02 D 0x03 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 For example 0 or 1 0x03 0x04 0x00 0x00 0x00 A 2 0x03 0x04 0x02 0x01 0x02 0x03 Changing 0x05 0x01 0 0 00 reader s ID 10 decimal serial number Err other For example MFO IC S50 S70 R
5. ProCom_CMD 0x21 N N bytes data 0x00 N N bytes data For example 15014443 Halt card 0x30 0x01 A 0x00 0 0 NNNNNNNNNNNN 12byte serial number TYPE B A 0 REQB 1 WUPB AT88SF020 fom Password 0x33 0x08 PPPPPPPP 0x00 0x00 certify P P 8 byte password For example Read data 0x34 0x01 BPPPPPPPP 0x00 0x08 DDDDDDDD block 8 bytes data B 1 byte data for block serial For example Write data 0x35 0x09 BDDDDDDDD 0x00 0x00 block B 1byte data for block serial D D 8 bytes data For example lock 0x36 0x04 DDDD 0x00 0x00 11 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 ISO14443 For example TYPEB counting 0x37 0x06 DDDDDD 0x00 0x00 D D 6 bytes data for AT88SF020 signature For example ATTRIB 0x38 0x04 DDDD 0x00 0x00 For example 15015693 Read single tag serial 0x50 0x00 0x00 0x09 22 l code SLI Tag it No 5 5 8 bytes serial number ISO14443 For example TYPEB Read multiple cards 0x51 0x01 N 0x00 0x09 N DSSSSSSSS DSSSSSS serial number Read cards qty SS AT88SF020 D 1byte DSFID S S 8byte serial number For example Obtain system Info 0 52 0 09 FSSSSSSSS 0x00 a FSSSSSSSSDAPPP x0e F Indication F Bit4 1 valid command S 8 8 byte serial number D 1 byte DSFID only for the card in SELECT A 1 byte AFI condition Ppp Bits 1 valid command only when UID matched For example 12 ID Innovations D
6. atasheet for 101 3in1 v3 01 2008 5 01 15015693 Write DSFID 0x53 0x0A FSSSSSSSSD 0x00 0x00 l code SLI F Indication Tag it Bit4 1 valid command only for the ISO14443 card in SELECT condition TYPEB Bit5 1 valid command only when UID matched BIT6 1 TAGit AT88SF020 0 ICODE SLI S 8 8 bytes serial number D 1 byte DSFID For example Lock DSFID 0x54 0x09 FSSSSSSSS 0x00 0x00 F Indication Bit4 1 valid command only for the card in SELECT condition Bit5 1 valid command only when UID matched BIT6 1 TAGit 0 ICODE SLI 5 5 8 bytes serial number For example 13 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 15015693 Write AFI 0x55 Ox0A FSSSSSSSSA 0x00 0x00 l code SLI F Indication Tag it Bit4 1 valid command only for the card ISO14443 in SELECT condition TYPEB Bit5 21 valid command only when UID matched BIT6 1 TAGit AT88SF020 0 ICODE SLI S S 8bytes serial number A 1 byte AFI For example Lock AFI 0x56 0x09 FSSSSSSSS 0x00 0x00 F Indication Bit4 1 valid command only for the card in SELECT condition Bit5 21 valid command only when UID matched BIT6 1 TAGit 0 ICODE SLI 5 8 8 bytes serial number For example 14 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 0 57 0x0B FSSSSSSSSBX 08 0x04 DDDD F
7. equest 0x10 0x00 Ok 0 0x02 NN Command Card Err Other 0x4400 ultra_light 0x0400 Mifare_One S50 0x0200 Mifare_One S70 0x4403 Mifare_DESFire 0x0800 Mifare_Pro 0x0403 Mifare ProX 0x0033 SHC1102 For example 0x10 0x00 0x00 0x02 0x04 0x00 Halt Module 0x11 0x00 Ok 0 0x00 Err Other For example 0x11 0x00 0x00 0x00 Read Seris 0x12 0x00 Ok 0 0x04 NNNN No Err Other For example 0x12 0x00 0x00 0x04 0x1B 0x2C 0x3D 0x4E ID Innovations Datasheet for PR101 MF 3in1 v3 01 2008 5 01 Read Block 0x13 Data For example MFO IC S50 S70 Command Write Block 0x14 Data For example 0x08 0x18 E r 0 REX IXFF UXFF UXrF BAPPPPPP B BlockNo S50 0x00 0x3f 570 0 00 0 A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6bytes Key BAPPPPPP DDDDDDDDDDDDDDDD B BlockNo S50 0x00 0x3f 570 0 00 0 A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6bytes Key DDDDDDDDDDDDDDDD 16 Bytes Data Ok 0 Err Other Ok 0 Err Other OxOF 0x00 DDDDDDDDDDDDDDDD 16 Bytes Data ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 Verify KeyA 0x15 0x0e BAPPPPPPMMMMMM Ok 0 0x00 B BlockNo Err Other S50 0x00 0x3f 570 0 00 0 A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 Bytes Old Key A MMMMMM 6 Bytes Old Key A For e
8. he Purse function you must Write Purse with any amount to initialize it When you operating the write block and changing the password A the VB demo will automatically add a O before the number you write When you operating the purse write increase decrease the VB demo will automatically add a O followed the number you write The software will automatically do the Caps for the character you type in All the writing and password and purse operating can only between 0 For the Purse write increase decrease the money amount is DDDD 4 bits For example 5 will be 0x00 0x00 0x00 0x05 It is not necessary to have checksum password for the Ultra light card writing It is A 2 NO AUTHEN Refer to the Protocols Saving a password into EEPROM The address of the RC500 chip for password is 80 1FF There are 6 bytes for Key A or Key B plus reversing saving there are 12 bytes for key A or Key B and 24 bytes for both keys There are totally 384 bytes in EEPROM organized as 16 blocks The commands in RED are not capable for all models 9
9. in1 v3 01 2008 5 01 SIM CARD LOGIN 0x70 PPPP 4 bytes password For example Change Sim Card Ox71 PPPP Password 4 bytes password WRITE 0X72 NPPPP N 0 SUK 1 2 KEY2 3 KEYS RESET 0X73 18 ID Innovations Datasheet for PR101 MF 3in1 v3 01 2008 5 01 Card Operating 10 11 12 13 Warning Accesss Bits Read card manual before proceeding or card may be blocked Block operation a For STD MF S50 SECOTOR is from 0 to 15 The BLOCK is from 0 to 63 b For STD MF S70 SECOTOR is from 0 to 39 1 sector include 4 blocks in the first 32 sectors and 1 sector include 16 blocks in the last 8 sectors The BLOCK is from 0 to 255 c For S70 or Ultra light You may change the Block in the Protocols Warning BLOCK3 of each Sector is a control area which can change the password A and password B It is very important to write the correct number in this block otherwise will cause the sector damaging For the safety purpose the demo software we provide is only available for password A operating which normally use very often you can change the password A For the Password B conducting we locked the function for safety purpose Please use the protocol as a reference to operate it You can switch the module into low consumption mode by using command HALT Module and command REQUEST before starting to use again When using t
10. xample 0x15 0 0 0x01 0x00 0xFF OxFF OxFF OxFF OxFF OxFF 0x11 0x22 0x00 0x00 0x33 0x44 0x55 0x66 MFO S50 S70 Read Purse 0x16 0x08 BAPPPPPP Ok 0 0x04 DDDD Command Err Other B BlockNo S50 0x00 0x3f 570 0 00 0 A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 Bytes Key For example 0x15 OxOd 0x01 0x00 0xFF OxFF OxFF OxFF OxFF OxFF 0x00 0x04 0x11 0x22 0x33 0x44 ID Innovations Datasheet for 101 3in1 v3 01 2008 5 01 MFO IC S50 S70 Write Purse 0x17 0 0 BAPPPPPPDDDD Ok 0 0x00 Command Err Other B BlockNo 550 0 00 0 31 570 0 00 0 A 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 Bytes Key DDDD 4 Bytes Purse Value For example MFO IC S50 S70 Increment 0x18 0 0 BAPPPPPPDDDD Ok 0 0x00 Command Purse Err Other B BlockNo S50 0x00 0x3f 570 0 00 0 0 AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 Bytes Key DDDD 4 Bytes Purse Value For example ID Innovations Command MFO IC S50 S70 Decrement Purse Datasheet for 101 3in1 v3 01 2008 5 01 0 0 BAPPPPPPDDDD B BlockNo S50 0x00 0x3f 570 0 00 0 0 PICC_AUTHENT1A 1 PICC_AUTHENT1B 2 NO_AUTHEN PPPPPP 6 Bytes Key DDDD 4 Bytes Purse Value gt Ok 0 Err Other 0x00 For example 0x19 OxOc 0x01 0x00 0xFF OxFF OxFF