Home
elation rayzor q7 - user manual 2.1
Contents
1. ELATION RAYZOR Q7 user manual 2 1 zo yozava NOILW14 PU J9SN LC ELATION 1 1 Qo www elationlighting com 2013 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat
2. ESSAS Po LN TAS gt SZ ZN DO SS XA SS D LL ON Sz Ss a ZN SS b LENI 12 RAYZOR Q7 User Manual 2 1 www elationlighting com 1 Omega holders 2 Clamp 3 Safety rope 4 Quick lock fastener Li O SECURING e Secure the clamp to the bracket using a M12 screw fitted through the P13 center hole e Insert the Turn Twist Locks of the first Omega bracket into the respective holes on the bottom of the device Tighten the Twist Locks a turn clockwise e Install the second Omega bracket on the top of the device in the same way e Pulla safety cable through the holes on the bottom of the base and over the trussing system or a safe installation Notice This step is very important to ensure the fixture will not drop out by the damage of the clamp 13 RAYZOR Q7 User Manual 2 1 www elationlighting com UNDERSTANDING DMX DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers DMX allows all makes and models of different manufactures to be linked together and operate from a single controller This is possible as long as all the fixtures and the controller are DMX compliant A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light DMX data is s
3. PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Macro Color Preset Color Mode Color Patter Chase Speed and tap ENTER to confirm selection 4 Tap UP to select desired value 0 255 and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu EFFECT ADJUST Calibration Adjust PAN and TILT to desired positions password is 050 NOTE A correct password must be entered in the Password menu in order to access PAN and TILT adjustment menu items 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Effect Adjust is highlighted and tap ENTER Tap UP DOWN until Calibration is displayed and tap ENTER 3 Tap UP DOWN to select desired function PAN or TILT and tap ENTER to confirm selection 4 Tap UP to select desired value 0 255 and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu 33 RAYZOR Q7 User Manual 2 1 www elationlighting com USER MODE SETTING Select different channels list by different seguence For example after the user enter this manual if select Auto Program CH 22 means in this User s mode the Dimmer is in Channel 16 USER MODE SETTING User Mode Create user defined channel orders the default is Stand Mode 1 Tap MODE ESC to a
4. 8 13 E P 1 m Distance m 40 3 40 6 4 0 9 77 Diameter m 40 58 41 16 1 74 13 Diameter m 47 RAYZOR Q7 User Manual 2 1 www elationlighting com DIMENSIONAL DRAWINGS millimeters 2905 2775 Gel holder Front snoot Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 48 RAYZOR Q7 User Manual 2 1 www elationlighting com CIRCUIT SCHEMATIC 49 RAYZOR Q7 User Manual 2 1 OPTIONAL ACCESSORIES ORDER CODE ITEM DESCRIPTION RAY047 SNOOT Snoot Lens Cover RAY047 GFH Diffusion Filter Holder 50 www elationlighting com RAYZOR Q7 User Manual 2 1
5. Program selection for Auto Pro Part Select Edit Program by turning the encoder Press the ENTER button to confirm Select Select Programs by turning the encoder Press the ENTER button to confirm Tum the encoder to select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and thus select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 37 RAYZOR Q7 User Manual 2 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued 4 Program Selection for Edit Program Select Edit Program by turning the encoder Press the ENTER button to confirm Select Edit Program by turning the encoder Press the ENTER button to confirm Turn the encoder to select the desired program With this function you can edit specific scenes into a specific program Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 5 Automatic Scene Recording Select Edit Program by turning the encoder Press the ENTER button to confirm Select Edit Scenes by turning the encoder Turn the encoder to select the desired scene numbers You can program a maximum number of 250 scenes Press the ENTER butto
6. for running Auto Programs Select the desired internal programs under Select Program set the number of steps under Edit Program and edit the individual scenes under Edit Scenes 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until Auto Program is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Master Alone and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu FUNCTION Sound Control Define the fixture mode Master or Alone for running Auto Programs via sound activation default is Master 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until Sound Control is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Master or Alone and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu 22 RAYZOR Q7 User Manual 2 1 www elationlighting com INFORMATION Time Information Current Time Display the run time of the fixture from last power ON The counter is reset after each time the device is powered OFF 1 Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN buttons until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Current Time is displayed tap ENTER and XXXXXh Hours is displayed 4 Tap MODE ESC to return
7. 60Hz Fuse Protection 250 T3 15A Power Consumption Watts Ambient Operating Temperature LIGHT SOURCE Type 7 x 15W QUAD COLOR RGBW LEDs 100 000 Rated Hours May vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming 14 F to 113 F 10 C to 45 C Life Time PHOTOMETRIC DATA 7 Beam 13 Field Angles COLOR MIXING RGBW Additive Color Mixing 16 7 Million Color Possibilities STROBE DIMMER Variable Speed Strobe 1 18 Flashes Per Second 0 100 Dimmer DMX CHANNELS 15 Basic 17 Standard 29 Extended DMX DRIVE USITT DMX 512 5 pin XLR Pin 3 Pin 2 Ground Pin 1 Starting DMX 001 PAN TILT Pan Movement 540 630 540 90 Offset Tilt Movement 265 SIZES WEIGHTS 9 3 L x 5 6 W x 12 5 H Head Vertical Dimensions 235 x 141 x 318 mm 12 9 326 5mm H Head Horizontal with Snoot Weight net 10 6 Ibs 4 8kgs RATINGS IP RATING IP20 Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 46 RAYZOR Q7 User Manual 2 1 www elationlighting com PHOTOMETRIC DATA Beam Angle 7 Field Angle 13 Intensity LUX RED 2817 756 295 GREEN 6650 1768 768 BLUE 910 250 108 WHITE 8963 2310 1001 FULL 15500 3920 1743 E a O a
8. A New White Balance 255 MACROS 00 CHASE SPEED FR 255 Fast To Slow Fast To Slow ee O RESET INTERNAL PROGRAMS 79 Normal mema Progra 7 49 ER 41 RAYZOR Q7 User Manual 2 1 www elationlighting com LED GROUPS 42 RAYZOR Q7 User Manual 2 1 www elationlighting com ERROR MESSAGE When the fixture is powered ON it goes through a motor reset program first before it is ready The display may show Err channel is XX if there are problems with one or more channels XX stands for channel 1 2 3 4 5 and 6 which has the testing sensor for positioning For example when the display shows Err channel is Pan movement it means there is some error in channel 1 If there are errors on channel 1 channel 3 channel 6 at the same time you may see the error messages Err channel is Pan movement Err channel is Tilt movement Err channel is red led flash 2 times and then the fixture will go through a second motor reset program If the error messages remain after performing 2 motor resets only the channels that have errors will not work properly all other channels will work normally Please contact Elation Professional Customer Support for service Service Hours are Monday through Friday 8 00 a m to 5 00 p m Pacific Standard Time Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com Forum www ElationLighting com forum PA
9. Address 18 Address 1 15 RAYZOR Q7 User Manual 2 1 www elationlighting com DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator Elation part DMX T PACK will decrease the possibilities of erratic behavior Termination reduces signal errors and avoids signal transmission problems JI and interference Itis always advisable l to connect a DMX terminal Resistance IL 120 Ohm 1 4 W between PIN 2 DMX PN and PIN 3 DMX of the last fixture 5 Pin XLR DMX CONNECTORS Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The following chart details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conversion 3 Pin XLR Female Out 5 Pin XLR Male In Das a oe 7 S owe 16 RAYZOR Q7 User Manual 2 1 www elationlighting com DMX ADDRESSING All fi
10. Down buttons to adjust the field Tapping the ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by tapping the MODE ESC button NOTE To access the LCD Menu Control Display via the internal battery press and hold the DC SWITCH button for 2 seconds The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press To shut OFF the LCD Menu Control Display immediately set Reset Default menu option to ON in the Personality menu and tap ENTER button to confirm your selection DC Switch 6 Rayzor 7 66 3 8 02mf 60 69 18 RAYZOR Q7 User Manual 2 1 PROFESSIONAL www elationlighting com RAYZOR Q7 SYSTEM MENU Default Settings Shaded Set DMK Address A001 AXXX DMX Address Setting DMX Value ALL DMX Value Display FUNCTION Slave Mode Slave1 Slave2 Slave3 Slave Setting Auto Program Master Alone Auto Program Sound Control Master Alone Music Control Current Time XXXX Hours Power On Running Time Total Run Time XXXX Hours Fixture Running Time ime Last Run Time XXXX Hours Fixture Last Times Clear Information INFORMATION Timer Password Password XXX Timer Password 038 Clear Last Run ON OFF Clear Fixture Last time Temperature Info Head Temperature Temperature In The Head Software Version V1 0 Software Version Address via DMX ON OFF Addr
11. any loss or damage direct or consequential arising out of the use of or inability to use this product G This warranty is the only written warranty applicable to Elation Professional Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 6 RAYZOR Q7 User Manual 2 1 ELATION 1 1 QO www elationlighting com SAFETY INSTRUCTIONS The RAYZOR Q7 is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device is grounded properly and only qualified personnel perform all electrical connections CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock CAUTION Keep this device away from rain and moisture CAUTION Unplug mains lead before opening the housing e For proper operation follow the Installation guidelines described on page 11 of this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts bra
12. designed for use on stage in nightclubs theatres etc Do not attempt installation and or operation without proper knowledge of how to do so Do not permit operation by persons who are not qualified for operating this type of theatrical fixture Most damages are the result of operations by nonprofessionals If this fixture is exposed to extreme temperatures due to environmental changes do not power the fixture on until it has reached room temperature Condensation could damage the fixture Consistent operational breaks may ensure the fixture will function properly for many years to come Do not shake fixture avoid brute force when installing and or operating the device When choosing an installation location please be sure this fixture will not be exposed to extreme heat moisture and or dust The minimum distance between this fixture and other devices or wall and or flat surface should be at least 0 5 meter 1 5 ft When using quick release OMEGA Cam Lock system be sure the four quick lock fasteners are locked in the quick lock holes correctly Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the base of the fixture Please use the original packaging and materials to transport the fixture in for service 8 RAYZO
13. qualified electrician CAUTIONS e Recommended ambient temperature for this fixture is between 14 F to 113 F 10 C to 45 C Do not use the fixture under or above this temperature e For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture e Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 46Kgs 102 Lbs e Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable e Never stand directly below the device when mounting removing or servicing the fixture 11 RAYZOR Q7 User Manual 2 1 www elationlighting com MOUNTING POINTS e Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury e Be sure the fixture is kept at least 0 5m 1 5 feet away from any flammable materials decoration etc 0 0 CT OS BSS CTT A a A 20 KA N Ny se CT Po LN NI Ae SN S SZ SEES O SZ Z SX Ye af SN NET gt NS ZS LSE SK OUA
14. the Control Panel buttons automatically after exiting main menu for 15 seconds Unlock by keeping the MODE ESC button pressed for 3 seconds Default is OFF 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Display Setting is displayed and tap ENTER 3 Tap UP DOWN until Key Lock is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu 30 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Display Setting Disp Flash Control Panel display will flash if no DMX is signal is detected default is OFF 1 Tap MODE ESC to access the main menu tap UPIDOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Display Setting is displayed and tap ENTER 3 Tap UP DOWN until Disp Flash is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection Tap MODE ESC to retum to the main menu PERSONALITY Temperature C F Display the temperature in Celsius or Fahrenheit default is Fahrenheit 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Temperature C F is displayed and tap ENTER 3 Tap UP DOWN to
15. to the main menu INFORMATION Time Information Total Run Time Display the total running time of the fixture 1 Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Total Run Time is displayed tap ENTER and XXXXXh Hours is displayed 4 Tap MODE ESC to return to the main menu INFORMATION Time Information Last Run Time Display last the running time of the lamp 1 Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Last Run Time is displayed tap ENTER and XXXXXh Hours is displayed 4 Tap MODE ESC to return to the main menu 23 RAYZOR Q7 User Manual 2 1 www elationlighting com INFORMATION Time Information LastRun Password Display the timer password 038 li YS Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER Tap UP DOWN until Time Information is displayed and tap ENTER Tap UP DOWN until LastRun Password is displayed and tap ENTER Tap UP DOWN to select 3 digit password and tap ENTER to confirm selection Tap MODE ESC to return to the main menu INFORMATION Time Information Clear
16. 2 6468 EW Kerkrade Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu 2 RAYZOR Q7 User Manual 2 1 www elationlighting com CONTENTS General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Features amp Fixture Overview 9 Installation 11 Understanding DMX 14 Fixture Menu 18 DMX Channel Values 40 LED Groups 42 Error Message 43 Snoot amp Diffusion Filter Installation 44 Cleaning and Maintenance 45 Technical Specifications 46 Optional Accessories 50 3 RAYZOR Q7 User Manual 2 1 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable lighting fixtures on the market today The RAYZOR Q7 has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance UNPACKING Thank you for purchasing the RAYZOR Q7 by Elation Professional Every RAYZOR Q7 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully
17. Last Run Clear the last run time of the fixture default is OFF 10 Tap MODE ESC to access main menu tap UPIDOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN until Time Information is displayed and tap ENTER 3 Tap UP DOWN until Clear Last Run is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection NOTE A correct password must be entered in the LastRun Password menu in order to clear last run time Tap MODE ESC to return to the main menu INFORMATION Temperature Information Head Temperature Display the temperature of the fixture default is Fahrenheit 1 aA eS Tap MODE ESC to access main menu tap UP DOWN LEFT RIGHT until Information is highlighted and tap ENTER Tap UP DOWN buttons until Temperature Info is displayed and tap ENTER Tap UP DOWN buttons until Head Temp is displayed and tap ENTER Tap ENTER and XXX degrees C F is displayed Tap MODE ESC to return to the main menu 24 RAYZOR Q7 User Manual 2 1 www elationlighting com INFORMATION Software Version Display the software version of the fixture li Tap MODE ESC to access main menu tap UPIDOWN LEFT RIGHT until Information is highlighted and tap ENTER 2 Tap UP DOWN until Software Version is displayed and tap ENTER 3 The display will show VX X soft
18. N Movement Er PAN yoke movement error This message will appear after completing the motor reset if the PAN movement is not located in the default position after the reset This error can happen if the yoke s magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor or its driving IC on the main PCB is defective or fails TILT movement Er TILT head movement error This message will appear after completing the motor reset if the TILT movement is not located in the default position after the reset This error can happen if the head s magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor or its driving IC on the main PCB is defective or fails 43 RAYZOR Q7 User Manual 2 1 www elationlighting com SNOOT amp DIFFUSION FILTER INSTALLATION SNOOT SKU RAY047 SNOOT To install place on top of Lens assembly and fix three screws as shown in diagram below Fix three screws DIFFUSION FILTER SKU RAY 047 GFH To install place on top of Lens assembly and fix three screws as shown in diagram below Fix three screws 44 RAYZOR Q7 User Manual 2 1 www elationlighting com CLEANING AND MAINTENANCE CAUTION Disconnect from mains before starting maintenance operation CLEANING Freguent cleaning is recommended to insure proper function and an extended fixture life e Clean each LED lens weekly to avoid weakness of light due to dust accumula
19. NTER to confirm selection Tap MODE ESC to return to the main menu 27 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Status Settings Mic Sensitivity Select desired Microphone Sensitivity from 0 to 99 default is 70 Ts Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Mic Sensitivity is displayed and tap ENTER 4 Tap UP DOWN to select desired value 00 to 99 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings Hibernation Select desired Hibernation time default is 15m 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Hibernation is displayed and tap ENTER 4 Tap UP DOWN to select desired value OFF 01m to 99m and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Service Setting Password The Password is 050 1 ee IS gt Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER Tap UP DOWN until Service Setting is displayed and tap ENTER Tap UP DOWN u
20. R 2 Tap UP DOWN until Edit Scenes is displayed and tap ENTER 3 Tap UP DOWN to select desired Scene number Scene 001 Scene 250 and tap ENTER to confirm selection 4 Tap UP DOWN to select desired function Auto Program PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Macro Color Preset Color Mode Color Patter Chase Speed Fade Time Secne Time Input By Out and tap ENTER to confirm selection 5 Tap UP DOWN to select desired position 0 255 and tap ENTER to confirm selection 6 Tap MODE ESC to return to the main menu EDIT PROGRAM Record Controller The fixture features an integrated DMX recorder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head EDIT PROGRAM Record Controller Working With Built In Program A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Aut
21. R Q7 User Manual 2 1 FEATURES www elationlighting com The new Rayzor Q7 features 7 15W Quad Color RGBW LEDs with up to 100 000 hour average life high speed 16 bit resolution movement color mixing rainbow effect 7 beam and 13 field angles 4 zone chase effects 8 auto program chase effects flicker free operation for TV and Film Spin DMX connections full color 180 reversible LCD menu display with 6 button touch control panel with battery backup for menu display power and a multi voltage universal auto switching power supply 100 240v Optional accessories for the Rayzor Q7 include a snoot lens cover and diffusion filter holder FIXTURE OVERVIEW BA 9 LED Lens Assembly DC Switch Microphone LCD Menu Control Display MODE ESC Button ENTER Button LEFT Button DOWN Button UP Button 10 RIGHT Button 11 5 Pin DMX OUT 12 5 Pin DMX IN 13 Power Switch 14 Fuse 15 Power IN 16 Power OUT RAYZOR Q7 User Manual 2 1 www elationlighting com 1 LED Assembly RGBW Quad LEDs comprise the LED assembly 2 DC Switch Controls menu and display power when disconnected from main power 3 Microphone Captures external low frequency sounds to trigger the unit in Sound Active mode Designed to capture low frequency sounds only tapping on the microphone and or high pitched sounds may not trigger unit 4 LCD Menu Control Display Full color LCD a
22. XLR connector on either end of the cable Also remember that a DMX line must be daisy chained and cannot be split unless using an approved DMX splitter such as the Elation Opto Branch 4 or DMX Branch 4 TM 14 RAYZOR Q7 User Manual 2 1 ELATION 1 1 www elationlighting com DMX Output DMKX Input DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket 5 Pin XLR Socket 5 Pin XLR Socket 1 Ground 1 Ground 2 Data 2 Data B 0 3 Data 3 Data 4 Open 5 Open Be sure to follow the above figure when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR outer casing Grounding the shield could cause a short circuit and erratic behavior DMX 512 CONTROLLER CONNECTION Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the RAYZOR Q7 Please refer to the diagram below You can chain multiple panels together through serial linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4 or DMX Branch 4 gt DMX512 DMX controller Address 35
23. access the main menu tap UP DOWN LEFT RIGHT until Reset Function is highlighted and tap ENTER Tap UP DOWN to select desired mode Reset ALL or Reset Pan Tilt and tap ENTER to confirm selection EFFECT ADJUST Test Channel Test each DMX function 1 Tap MODE ESC to access the main menu tap UPIDOWN LEFT RIGHT until Effect Adjust is highlighted and tap ENTER Tap UP DOWN until Test Channel is displayed and tap ENTER Tap UP DOWN to select desired function Auto Program PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Macro Color Preset Color Mode Color Patter Chase Speed and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu 32 RAYZOR Q7 User Manual 2 1 www elationlighting com EFFECT ADJUST Manual Control Fine adjustment All effects will be canceled the shutter opens and the dimmer intensity will be set to 100 Yo With the individual functions you can focus the light on a flat surface wall and perform the fine lamp adjustment 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Effect Adjust is highlighted and tap ENTER Tap UP DOWN until Manual Control is displayed and tap ENTER 3 Tap UP DOWN to select desired function Auto Program PAN
24. ave And Automatically Scene 001 Edit Scenes Blue 1 4 White 1 4 Return Manual Scene 125 Color Macro Color Scenes Edit Preset Color Mode Chase Patter Chase Speed Fade Time Scene Time Input By Output Automatic Scenes Record Controller XX XX Recorder FUNCTION Set DMX Address Adjust the desired DMX address via the Control Panel 1 2 3 Tap MODE ESC to access the main menu and tap ENTER Tap the UP DOWN until Set DMX Address is displayed and tap ENTER Current DMX address is displayed 001 509 tap the UP DOWN to select desired DMX address 001 509 and ENTER to confirm selection Tap MODE ESC to return to the main menu 21 RAYZOR Q7 User Manual 2 1 www elationlighting com FUNCTION DMX Value Display the DMK 512 value of each channel 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until DMX Value is displayed and tap ENTER 3 Tap UP DOWN to select desired DMX Value and ENTER to confirm selection 4 Tap MODE ESC to return the main menu FUNCTION Slave Mode Define the fixture as a slave 1 Tap MODE ESC to access the main menu and tap ENTER 2 Tap UP DOWN until Slave Mode is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Slave1 Slave2 Slave3 and tap ENTER to confirm selection 4 Tap MODE ESC to retum to the main menu FUNCTION Auto Program Define the fixture mode Master or Alone
25. aximum degree of the Tilt movement default is Tilt 270 Ts Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Tilt Degree is displayed and tap ENTER 4 Tap UP DOWN to select desired mode Tilt 270 Tilt 240 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings Feedback Select desired Feedback switch setting of the Pan Tilt movement default is ON 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Feedback is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings Movement Speed Select desired Movement Speed default is Speed 1 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UPIDOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Movement Speed is displayed and tap ENTER 4 Tap UP DOWN to select desired mode Speed 1 Speed 2 Speed 3 Speed 4 and tap E
26. ccess the main menu tap UP DOWN LEFT RIGHT until User Mode Set is highlighted and tap ENTER Tap UP DOWN until User Mode is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Stand Mode Basic Mode Extend Mode User Mode A User Mode B User Mode C and tap ENTER to confirm selection Tap MODE ESC to return to the main menu USER MODE SETTING Edit User Mode A B C Adjust the rest user defined channel order lly Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until User Mode Set is highlighted and tap ENTER Tap UP DOWN to select desired user Edit User Mode A Edit User Mode B Edit User Mode C is displayed and tap ENTER Tap UP DOWN to select desired mode Max Channel Auto Program PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Macro Color Preset Color Mode Color Patter Chase Speed and tap ENTER to confirm selection Tap UP DOWN to select desired channel None 01Ch 17Ch and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 34 RAYZOR Q7 User Manual 2 1 www elationlighting com EDIT PROGRAM Select Program Select Auto Programs default for Auto Pro Part1 is Program 1 for Auto Pro Part2 is Pr
27. ckets holders clamps safety cables included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury e Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times e The fan and air inlets must remain clean and never blocked Allow approx 6 15cm between this fixture and other devices or a wall for proper cooling e Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord e Do not operate this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating 7 RAYZOR Q7 User Manual 2 1 www elationlighting com GENERAL GUIDELINES NEVER OPEN THIS FIKTURE WHILE IN USE During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This fixture is a professional lighting effect
28. ed and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Pan Reverse is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings Tilt Reverse Reverse the Tilt movement default is OFF 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Tilt Reverse is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings Pan Degree Select desired maximum degree of the Pan movement default is 540 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Pan Degree is displayed and tap ENTER 4 Tap UP DOWN to select desired mode Pan 540 Pan 540 90offset Pan 630 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 26 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Status Settings Tilt Degree Select desired m
29. ent out as serial data that travels from fixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use proper DMX cables and a terminator When using several DMX fixtures try to use the shortest cable path possible Never split a DMX line with a Y style connector The order in which the fixtures are connected in 8 DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain The RAYZOR Q7 can be controlled via DMX 512 protocol The RAYZOR Q7 is a 64 channel DMX fixture The DMX address is set electronically using the controls on the LCD menu DATA CABLE DMX Cable REQUIREMENTS For DMX and Master Slave Operation Your fixture and your DMX controller require a standard 3 pin or 5 pin XLR connector for data input and data output see figure below If you are making your own cables be sure to use two conductor shielded digital DMX cable rated at 120 ohms this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers Your cables should be made with a male and female
30. ess Via DMX No DMX Status Close Hold Auto Music Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 54 0offset 540 Pan Degree Select 1 2 3 Status Settings Tilt Degree 270 240 Tilt Degree Select 1 2 Feedback ON OFF Movement Feedback Movement Speed Speed 1 4 Movement Mode Select Mic Sensitivity 0 99 Sensitivity of Microphone Hibernation OFF 01M 99M 15M Stand By Mode Password Password XXX Service Password 050 Service Setting RDM PID XXXXXX RDM PID Code PERSONALITY Auto Fans Control High Fans Speed Select Low Shutoff Time 02 60m 05m Display Shut Off Time Flip Display ON OFF Display Reverse 180 Display Setting Key Lock ON OFF Key Lock Display Flash ON OFF Display Flashes If No DMX Celsius Temperature Switch Temperature C F Fahrenheit Between C or F Initial Status PAN XXX Initial Effect Position Reset Default ON OFF Restore Factory Settings 19 RAYZOR Q7 User Manual 2 1 ELATION www elationlighting com RESET FUNCTION Reset All Reset Pan Tilt Reset All Settings Reset Pan Tilt Settings EFFECT ADJUST Test Channel Auto Program PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 Green 1 Blue 1 White 1 Red 2 Green 2 Blue 2 White 2 Red 3 Green 3 Blue 3 White 3 Red 4 Green 4 Blue 4 White 4 Color Macro Color Preset Color Mode Chase Patter Chase Speed Test Functions Manual Control Auto Pro
31. gram PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 Green 1 Blue 1 White 1 Red 2 Green 2 Blue 2 White 2 Red 3 Green 3 Blue 3 White 3 Red 4 Green 4 Blue 4 White 4 Color Macro Color Preset Color Mode Chase Patter Chase Speed Fine Adjustment of Functions 0 255 Calibration Password XXX 0 255 0 255 Password PAN TILT Password 050 Fine Adjustment of PAN Fine Adjustment of TILT USER MODE SETTING User Mode Stand Mode Basic Mode Extend Mode User Mode A User Mode B User Mode C Select DMX amp User Modes Edit User Mode A Edit User Mode B Edit User Mode C Max Chanel Auto Program PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 Green 1 Blue 1 White 1 Red 2 Green 2 Blue 2 White 2 Red 3 Green 3 Blue 3 White 3 Red 4 Green 4 Blue 4 White 4 Color Macro Color Preset Color Mode Chase Patter Chase Speed Preset User Modes 20 RAYZOR Q7 User Manual 2 1 Taah www elationlighting com Qu Auto Pro Part1 Program 1 10 Program 1 Auto Pro Part2 Program 1 10 Select Programs Select Program Program 2 To Be Run Auto Pro Part3 Program 1 10 Program 3 Testing Program Program 1 Pro Test Edit Program Program In Loop Program 10 Step 01 Step 64 Save And Exit Auto Program PAN PAN Fine TILT EDIT TILT Fine Move PROGRAM Speed Strobe Dimmer Red 1 4 Green 1 4 S
32. he United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professional concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up D
33. hether a DMX data signal is being received or not If DMX data signal is being received the display will show Addr XXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following The 3 PIN or 5 PIN XLR input plug cable with DMX signal from controller is not connected or is not inserted completely into the DMX input jack of the fixture The DMX controller is switched off or defective The DMX cable or connector is defective A DMX terminator has been inserted into the last fixture in your DMX chain 17 RAYZOR Q7 User Manual 2 1 www elationlighting com FIKTURE MENU ON BOARD SYSTEM MENU The RAYZOR Q7 comes with an easy to navigate system menu The next section will detail the functions of each command in the system menu LCD MENU CONTROL PANEL The control panel see image below located on back of the fixture allows you to access the main menu and make all necessary adjustments to the RAYZOR Q7 During normal operation tapping the MODE ESC button once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting tap the ENTER button to activate that field and use the UP and
34. inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS e 1 powerCON Power Cable e 1 5 Pin XLR Cable e 1 Omega Bracket Holder e 1 Safety Cable e Manual amp Warranty Card iar MANUAL UPDATES Please check www elationlighting com for the latest revision update of this manual 4 RAYZOR Q7 User Manual 2 1 www elationlighting com CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or suggestions For service related issues please contact Elation Professional Service Hours are Monday through Friday 8 00 a m to 5 00 p m Pacific Standard Time Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com Forum www ElationLighting com forum WARRANTY REGISTRATION The RAYZOR Q7 carries a two year 730 days limited warranty Please fill out the enclosed warranty card to validate yo
35. n to confirm Press the MODE ESC button in order to return to the main menu Example Program 2 includes scenes 10 11 12 amp 13 Program 4 includes scenes 8 9 amp 10 Program 6 includes scenes 12 13 14 amp 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 38 RAYZOR Q7 User Manual 2 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture Part 1 o seme set some mei Part 2 6 eee J Part 3 39 RAYZOR Q7 User Manual 2 1 ELATION 1 1 QO www elationlighting com DMX CHANNEL FUNCTIONS AND VALUES ELATIONO RAYZOR Q7 SKU RAY047 DMX Channel Values Functions 29 DMX Channels Specifications are subject to change without any prior written notice Mode Channel STAND BASIC EXTEND E E TS 1 1 1 Do PAN MOVEMENT 8 Bit 0 255 PAN Movement Do PAN MOVEMENT 16 Bit 2 2 0 255 Fine Control Of PAN Movement E TILT MOVEMENT 8 Bit 3 2 3 0 255 TILT Movement Do TILT MOVEMENT 16 Bit 4 4 0 255 Fine Control Of TILT Movement 03 SPEED PAN TILT MOVEMENT 0 225 Max To Min Speed 226 235 Blackout By Movement 236 255 NO Function Do RED LED All Groups 1 4 0 255 Red 0 Black 255 100 Do GREEN LED All Groups 1 4 0 255 Green 0 Black 255 100 40 BLUE LED All Group
36. nimated menu display 5 MODE ESC Button Used to access the menu functions and exit the current command 6 ENTER Button Used to enter into or lock a certain menu function 7 LEFT Button Used to toggle through the menu display 8 DOWN Button Used to toggle down or back through the menu functions and settings 9 UP Button Used to toggle forward through the menu functions and settings 10 RIGHT Button Used to toggle through the menu display 11 5 Pin DMX Accepts incoming DMX signal via a male 5 pin XLR jack 12 5 Pin DMX OUT Sends incoming DMX signal to the next fixture in the DMX chain via a female 5 pin XLR jack 13 Power Switch Used to power the unit ON or OFF 14 Fuse Holder Assembly Houses 250v T3 13A GMA safety fuse Always replace with an exact match unless otherwise specified by an authorized Elation Service Technician Using a fuse other than that specified could seriously damage the unit and may void the manufactures warranty 15 Power IN Power connection powerCon to power source 16 Power OUT Power connection powerCon to daisy chain to another unit 10 RAYZOR Q7 User Manual 2 1 www elationlighting com INSTALLATION CAUTION Please consider the GB7000 15 EN60598 2 17 and the other respective national norms during the installation The installation must only be carried out by a gualified person CAUTION The electric connection must only be carried out by a
37. ntil Password is displayed and tap ENTER Tap UP DOWN to select 3 digit password and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 28 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Service Setting RDM PID With this function you can call up various submenus via RDM This device is RDM ready RDM stands for remote device management and makes remote control of devices connected to the DMX bus ANSI E1 20 2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol Manual settings like adjusting the DMX starting address are no longer needed This is especially useful when the fixture is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX line The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices If DMX splitters are used and RDM control is to be used these splitters must support RDM The number and type of RDM parameters depend on the RDM controller being used 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Service Setting is displayed and tap ENTER 3 Tap UP DOWN until RDM PID is displayed and tap ENTER 4 Tap MODE ESC to return to the main menu PERSONALITY Fans Control Select desired Fan setting default is Auto 1 Tap MODE ESC to access the main me
38. nu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Fans Control is displayed and tap ENTER 3 Tap UP DOWN to select desired mode Auto Low High and tap ENTER to confirm selection 4 Tap MODE ESC to return to the main menu 29 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Display Setting Shutoff Time Shut off the Control Panel display after 02 to 60 minutes default is 05 minutes 1 Tap MODE ESC to access the main menu tap UPIDOWN LEFT RIGHT until Personality is highlighted and tap ENTER Tap UP DOWN until Display Setting is displayed and tap ENTER Tap UP DOWN until Shut off Time is displayed and tap ENTER Tap UP DOWN to select time 02 60 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 8 5 PERSONALITY Display Setting Display Reverse Rotate Flip the Control Menu Panel display by 180 default is OFF 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Display Setting is displayed and tap ENTER 3 Tap UP DOWN until Display Reverse is displayed and tap ENTER 4 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu PERSONALITY Display Setting Key Lock Lock
39. o Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 36 RAYZOR Q7 User Manual 2 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Program continued To start an Auto Program proceed as follows 1 Slave Setting Select Function Mode by turning on the encoder Press the ENTER button to confirm Select Set to Slave by turning the encoder Press the ENTER button to confirm Turn the encoder to select Slave 1 Slave 2 or Slave 3 Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 2 Automatic Program Run Select Function Mode by turning on the encoder Press the ENTER button to confirm Select Auto Program by turning on the encoder Press the ENTER button to confirm Turn the encoder to select Master or Alone The selection Alone means Stand Alone mode and Master that the device is defined as master Press the ENTER button to confirm Press the MODE ESC button in order to return to the main menu 3
40. ogram 2 and for Auto Pro Part3 is Program 3 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Edit Program is highlighted and tap ENTER Tap UP DOWN until Select Program is displayed and tap ENTER Tap UP DOWN to select desired Auto Program Part Auto Pro Part1 Auto Pro Part2 Auto Pro Part3 and tap ENTER to confirm selection Tap UP DOWN to select desired Program number Program 1 Program 10 and tap ENTER to confirm selection Tap MODE ESC to return to the main menu EDIT PROGRAM Edit Program Edit the internal programs 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Edit Program is highlighted and tap ENTER Tap UP DOWN until Edit Program is displayed and tap ENTER 3 Tap UP DOWN to select desired Program number Program 1 Program 10 and tap ENTER to confirm selection Tap UP DOWN to select desired test or step Pro Test Step 01 Step 64 and tap ENTER to confirm selection Tap UP DOWN to select desired scene Sc001 Sc250 or End and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 35 RAYZOR Q7 User Manual 2 1 www elationlighting com EDIT PROGRAM Edit Scenes Edit the scenes of the internal programs 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Edit Program is highlighted and tap ENTE
41. s 1 4 0 255 Blue 0 Black 255 100 Po WHITE LED All Groups 1 4 0 255 White 0 Black 255 100 EEE 0 255 Red 0 Black 255 100 Do GREEN LED Group 1 0 255 Green 0 Black 255 100 Do BLUE LED Group 1 0 255 Blue 0 Black 255 100 Do WHITE LED Group 1 0 255 White 0 Black 255 100 EEE 0 255 Red 0 Black 255 100 40 GREEN LED Group 2 0 E Green 0 Black 255 100 Do BLUE LED Group 2 0 255 Blue 0 Black 255 100 Do WHITE LED Group 2 0 255 White 0 Black 255 100 RED LED Group 3 0 255 Red 0 Black 255 100 Po GREEN LED Group 3 0 255 Green 0 Black 255 100 PY BLUE LED Group 3 0 255 Blue 0 Black 255 100 Po WHITE LED Group 3 0 255 White 0 Black 255 100 Lae 0 255 Red 0 Black 255 100 Po GREEN LED Group 4 0 255 Green 0 Black 255 100 Po BLUE LED Group 4 0 255 Blue 0 Black 255 100 E WHITE LED Group 4 0 255 White 0 Black 255 100 40 RAYZOR Q7 User Manual 2 1 ELATION 1 1 QO www elationlighting com ELATIONO RAYZOR Q7 SKU RAY047 DMX Channel Values Functions 29 DMX Channels Specifications are subject to change without any prior written notice Mode Channel STAND BASIC o SHUTTER STROBE 2 O DIMMER INTENSITY a 255 Intensity O to 100 EEE 12 10 No Function 8 255 Color Macro Slow To Fast QIE MODE _ Nors New White Balance 2 188 Store
42. select desired mode Celsius or Fahrenheit and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Initial Status Display the initial effect position for DMX functions 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UPIDOWN until Initial Status is displayed and tap ENTER 3 Tap UP DOWN to select desired function Auto Program PAN PAN Fine TILT TILT Fine Move Speed Strobe Dimmer Red 1 4 Green 1 4 Blue 1 4 White 1 4 Color Macro Color Preset Color Mode Color Patter Chase Speed and tap ENTER to confirm selection 4 Tap UP to select desired position 0 255 and tap ENTER to confirm selection 5 Tap MODE ESC to return to the main menu 31 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Reset Default Restore factory settings function ON or OFF the default is OFF 1 Tap MODE ESC to access the main menu tap UPIDOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Reset Default is displayed and tap ENTER 3 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection RESET FUNCTION Reset fixture function Reset ALL or Reset Pan Tilt 1 Tap MODE ESC to
43. tion e Clean fan weekly to avoid dust accumulation e Use a moist lint free cloth Never use alcohol or solvents MAINTENANCE Regular inspections are recommended to insure proper function and an extended life There are no user serviceable parts inside this fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections e A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating e Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall e Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person s e Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 45 RAYZOR Q7 User Manual 2 1 www elationlighting com TECHNICAL SPECIFICATIONS ELECTRICAL THERMAL Voltage Requirements AC 100 240V 50Hz
44. ur purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customers expense You may obtain a R A number by contacting customer support at 323 582 3322 IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 5 RAYZOR Q7 User Manual 2 1 ELATION 1 1 QO www elationlighting com 2 YEAR LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within t
45. uring the period specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professional in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional be liable for
46. ware version 4 Tap MODE ESC to return to the main menu PERSONALITY Status Settings Address Via DMX Adjust the desired DMX address via an external controller default is ON 1 Tap MODE ESC to access the main menu tap UPIDOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until Address Via DMX is displayed and tap ENTER 6 Tap UP DOWN to select desired mode ON or OFF and tap ENTER to confirm selection Tap MODE ESC to return to the main menu PERSONALITY Status Settings No DMX Status Fixture runs in Auto Run if no DMX signal is detected Options include Hold Close Shutter Music Control Auto Program default is Hold 1 Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlighted and tap ENTER 2 Tap UP DOWN until Status Settings is displayed and tap ENTER 3 Tap UP DOWN until No DMX Status is displayed and tap ENTER 4 Tap UP DOWN to select desired mode Hold Close Shutter Music Control Auto Program and tap ENTER to confirm selection Tap MODE ESC to return to the main menu 25 RAYZOR Q7 User Manual 2 1 www elationlighting com PERSONALITY Status Settings Pan Reverse Reverse the Pan movement default is OFF Ts Tap MODE ESC to access the main menu tap UP DOWN LEFT RIGHT until Personality is highlight
47. xtures should be given a DMX starting address when using a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture You can set the same starting address for all fixtures or a group of fixtures or set different address for each individual fixture Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the RAYZOR Q7 when in Extended 29 Channel mode default can also be set to Basic 15 Channel and Standard 17 Channel modes you should set the starting DMX address of the first unit to 1 the second unit to 30 29 1 the third unit to 59 29 30 the fourth unit to 88 29 59 and so on Note During start up the RAYZOR Q7 will automatically detect w
Download Pdf Manuals
Related Search
Related Contents
Lucien Barrière Hôtels et Casinos fête 100 années de prestige Cybersonic Power Toothbrush User's Manual Waste/recycle sets Anzeigen Manual de instruções do alicate wattímetro modelo Defibtech DDU-2000 Series Automated External Defibrillator • DDU English - Western Digital Piano di formazione_EMM Napoleon Grills CSS610RB Gas Grill User Manual Copyright © All rights reserved.