1. INSTALLATION INSTRUCTIONS EMPIRE AND OWNER S MANUAL COMFORT SYSTEMS ROCK CREEK WARNING If the information in these in structions are not followed exactly a fire or ex plosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppli er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier LOG SET FOR UNVENTED MULTI SIDED GAS FIREPLACE MODELS LSU24RR 2 GAS FIRED UL LISTED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence WARNING If not installed operated and main tained in accordance with the manufacturer s instructions this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness NATIONAL FIREPLACE INSTITUTE NF I CERTIFIED www nficertified org We suggest that our gas hearth products be installed and serviced by profes sionals who ar
2. Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater Candles Avoid the use of scented or decorative candles while the log set is in operation Candles produce a residue in air that creates a soot like substance Burning candles while the log set is operating magnifies the problem It should be noted that candles in general produce soot The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited Make Owners Aware of Proper Log Set Operation Properly installed and properly maintained log sets do not deposit soot on the logs If users see soot appear on a log call for service Do not continue to operate the log set The following WARNING applies when log set is installed onto an unvented gas burner assembly GENERAL INFORMATION Qualified Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency The term qualified agency means any individual firm corporation or company that either in person or through a representative is engaged in and 15 responsible for a the installation testing or replacement of gas piping or b the connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all precau tions required and that
3. has complied with all the requirements of the authority having jurisdiction The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 54 or International Fuel Gas Code Available from the American National Standards Institute Inc 11 West 42nd St New York N Y 10018 26705 0 1109 State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane and natu ral gas fired space heaters shall be prohibited in bedrooms and bathrooms Page 3 LOG PLACEMENT Before you begin Do not handle these logs with your bare hands Always wear gloves to prevent skin irritation After handling logs wash your hands gently with soap and water All Logs The positioning of the logs 1s critical to the safe and clean operation of this heater Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance Refer to Figures 1 and 2 for the following warning PROPER INSTALLATION SEQUENCE ATTENTION For the instructions below Front indicates the side of the burner with the air shutter to the right Facing the burner assembly with the pilot and air shutte
4. T cdd 24 Js XA TREATS res ear VN ERU A TRANS ANS a Wa 1 N LA e vis ae Pg Mer Log Placement LP Gas Burner Log Placement NAT Gas Burner LSU24RR 2 Logs LSU24RR 2 Logs Figure 3a Figure 3a Attention Do not use Figures 1 to3 to order replacement logs Refer to Page 8 Parts List and Parts View to order logs for your appropriate model number Figure 4 26705 0 1109 Page 5 EMBER PLACEMENT Apply loose material glowing embers with the appropriate ember placement See photos on pages 7 amp 8 Replacement of loose material glowing embers must be purchased from Empire Comfort Systems Inc Application of excess loose material glowing embers may adversely affect performance of the heater WARNING All previously applied loose material must be removed prior to reapplication Replacement Loose Material glowing embers Part Number Rock Wool 15999 Platinum Bright Embers PE 20 1 Note A single layer of embers is to be used when applying Platinum Bright Embers alone or in combination with production embers to the burner Page 6 26705 0 1109 EMBER PLACEMENT LSU24RR 2 PHOTOS LP GAS BURNER Some logs have been removed for clarity Do not cover any large ports with loose material glowing embers FRONT 26705 0 1109 Page 7 EMBER PLACEMENT LSU24RR 2 PHOTOS NAT GAS BURNER Some logs have been removed for clarity Do not cover any
5. e certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists Page TABLE OF CONTENTS Important Installation Guidelines eese 3 General Information 3 4 5 Ember Placement LSU24RR 2 Photos LP Gas 7 Ember Placement LSU24RR 2 Photos NAT Gas 8 Parts List amp Parts View CON SMS 9 How to Order Repair 10 n 10 11 Page 2 26705 0 1109 IMPORTANT INSTALLATION GUIDELINES Proper Log Placement Log placement is critical to proper burner performance Logs must be correctly positioned onto the burner The photos in this manual show the proper pinned position for logs on this set Owners need to be shown proper log placement and instructed not to move the logs Logs must fit firmly onto the burner when positioned as shown in the photos Malformed logs or logs with sloppy pin holes must be replaced Proper Placement of Rock Wool and Decorative Lava Rock Rock wool can be added to burners for a glowing ember effect It must be positioned only on the front portion of the burner The photos in this manual show the proper placement of rock wool Decorative lava rock or small wood pieces should never be placed
6. large ports with loose material glowing embers FRONT Page 8 26705 0 1109 PARTS LIST amp PARTS VIEW Attention When ordering parts it 15 very important that part number and description of part coincide Index No A B e D E F G H I K L USE ONLY MANUFACTURER S REPLACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH Part Number LSU24RR 2 R9323 R9717 R9720 R9326 R9873 R9328 R9366 R10282 R9319 R9321 R9322 26705 0 1109 Ma Description BACK RIGHT LOG RIGHT MIDDLE LOG LEFT BACK LOG LEFT MIDDLE LOG RIGHT FRONT LOG CENTER MIDDLE LOG LEFT FRONT LOG MIDDLE BOTTOM BRANCH MIDDLE TOP BRANCH TOP LEFT BRANCH TOP RIGHT BRANCH Page 9 HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer For best results the service person or dealer should order parts through the distribu tor Parts can be shipped directly to the service person dealer All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Appliance Model Number 0 Part Description Appliance Serial Number 0 0 Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are s
7. on the burner These items are only for placement on the floor of the fireplace Proper Primary Airflow into Burner For proper burner operation and flame appearance the flow of primary air into the venturi tube located on the rear of the burner must not be reduced This flow of air 1s reduced if dirt lint or other obstructions build up around or inside the venturi Any obstruction in the venturi tube area must be removed The flow of air into the venturi is also reduced if the gas orifice isn t centered in the venturi inlet and or 15 not aligned with the venturi Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube Ceiling Fans Portable Fans or Logs Installed Near Cold Air Returns Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent free logs If the air blows directly into the flame causing it to impinge on the log set or firebox it should be turned off or redirected Ceiling fans could be reversed to possibly eliminate flame impingement and the floor fan could be redirected Upon installation be aware of any cold air returns or vents in the proximity of the log set Any draft created around a vent free log set can cause the flame to impinge on the log and create a sooting situation WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns WARNING
8. r to the right place Back Right Log log A onto right back pins of burner Place Right Middle Log log B onto right middle pins of burner Place Left Back Log log C onto left back pins of burner Note Natural Gas burners will have a bracket to support this log Place Left Middle Log log D onto left middle pins of burner Place Right Front Log log E onto right front pin of burner Note Natural Gas burners will have a bracket to support this log Place Center Middle Log log F onto burner top against logs B and D Note On Natural Gas burners this log rests on top of the center log support plate 7 Place Left Front Log log G onto left front pins of burner Note Natural Gas burners will have a bracket to support this log 8 Insert boss of Middle Bottom Branch log H into recess on logs E B and C 9 Insert boss of Middle Top Branch log I into recess on log H Middle Bottom Branch and logs A and B 10 Insert boss of Top Left Branch log K into recess on logs C D and G 11 Insert recess of Top Right Branch log L into the recess on log A 12 Compare the completed log installation with Figure 4 Review previous steps to make any necessary adjustments 13 Log placement is complete ae NOTE When placed correctly the logs will not cover any ports Figure 1 Figure 2 LP Gas Burner Shown Natural Gas burner includes log support brackets Page 4 26705 0 1109 LOG PLACEMEN
9. tandard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes beyond our control SERVICE NOTES Page 10 26705 0 1109 SERVICE NOTES 26705 0 1109 Page 11 Empire Comfort Systems Inc PESE 918 Freeburg Ave Belleville IL 62220 f MP RE If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com Page 12 26705 0 1109