Home

USER MANUAL

image

Contents

1. Suction ON A DANGER Equipment not suitable for use in the presence of flammable anesthetic Caution must be exercised when operating the Easy Go Vac Aspirator where oxygen is being administered DO NOT use near any type of flame or flammable explosive substances DO NOT allow Aspirator to exceed Operating or Storage Temperature specifications TO REDUCE THE RISK OF ELECTROCUTION Always unplug the Easy Go Vac Aspirator after using except when battery is being recharged DO NOT use while bathing DO NOT place or store the Easy Go Vac Aspirator where it can fall or be pulled into a tub or sink DO NOT immerse into water or other liquid DO NOT reach for the Easy Go Vac Aspirator that has fallen into water Unplug immediately DO NOT attempt to repair the Easy Go Vac Aspirator Any attempt could result in electrical shock AWARNING TO REDUCE RISK OF BURNS ELECTROCUTION FIRE OR INJURY TO PERSONS Close supervision is necessary when this Easy Go Vac Aspirator is used by on or near children or invalids Use this Easy Go Vac Aspirator only for its Intended Use as described in this manual Keep the cord away from heated surfaces DO NOT use when sleepy or drowsy DO NOT use attachments not recommended by the Precision Medical Inc DO NOT use if the Easy Go Vac Aspirator has a damaged cord or plug DO NOT use if the Easy Go Vac Aspirator has been dropped or damaged
2. External Power Vacuum Control Knob Inline Hydrophobic Filter On Off Switch Vacuum A Gaug p Yellow E Patery SY G 306 v 1 Patient Me Tubing Connection h Suction Canister Built in overfill pro AC Power tection device os Suction Auto DC Tubing Power Cord optional GROUNDING INSTRUCTIONS The Battery Charger Power Supply should be grounded In the event of an electrical short circuit grounding reduces the risk of electrical shock by providing an escape wire for the electrical current This Battery Charger Power Supply is equipped with acord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded ADANGER Improper use of the grounding plug can result in a risk of electrical shock Battery Charger Power Supply AWARNING Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked Hospital Grade OPERATING INSTRUCTIONS CAUTION Inspect the Easy Go Vac Aspirator for visual damage DO NOT USE if damaged Place the Easy Go Vac Aspirator in the upright position on a level surface Make sure the On Off Switch is in the OFF position Ensure the Inline Hydrophobic Filter and tubing is properly connected to the vacuum port on the Suction Canister lid ACAUTION DO NOT run the Easy GO Vac Aspirator withou
3. USER MANUAL ASPIRATOR Model No PM65HG PM65E SAVE THESE INSTRUCTIONS ACAUTION Federal USA law restricts this device to sale by or on the order of a physician PRECISION MEDICAL 300 Held Drive Tel 001 610 262 6090 Northampton PA 18067 Fax 001 610 262 6080 www precisionmedical com CONTENTS BEGEIVING INSPEGCTION riore oen contr intor tu 2 INTENDED USE aiio prono iei e ab ea t ash Pg MEA 2 READ ALL INSTRUCTIONS BEFORE USING 2 EXPLANATION OF ABBREVIATIONS 2 SAFETY INFORMATION WARNINGS AND CAUTIONS 3 SPECIFICATIONS udo pau ee Soo si tt sa bed uos 5 COMPONENT DESCRIPTION 6 OPERATING 6 A AC Electrical Recepticle Operation 7 B Internal Battery 8 C Auto DC Operation 9 GHARGING BATTERY 25 055 ORI blister vini E 10 CLEANING MAINTENANCE 2 10 zio 11 DISPOSAL INSTRUGTIONGS 5 2t Mee ad o etos 11 TROUBLESHOOTING GUIDE sese 12 REPLACEMENT PARTS ctickesasest ese pex pa tea Up tea 13 LIMITED WARRANTY isis ips rca raa ada ead uc 14 RECEIVING INSPECTION Remove the Precision Medical Easy Go V
4. SPECIFICATIONS Dimensions in Carry Bag Length 12 30 cm Width 9 5 24cm Height 10 25 cm Weight with Carry Bag and all Accessories 9 6 lbs 4 4 kg Shipping Weight 11 Ibs 5 kg Suction Canister 800cc Max Volume Vacuum is not to exceed 25 inHg 84 7 kPa The Canister Lid has a float shut off valve that protects the Aspirator from overfill Patient Tubing 1 4 ID Non Conductive PVC tubing 6 ft long with 1 4 3 8 ID female connectors or equivalent Electrical Aspirator Unit 12 Volts DC 1 8 Amps Battery Charger Power Supply 100 240 Volts AC 50 60 Hz 0 80 0 35 Amps Internal Battery Type 12 Volt Sealed Lead Acid Vacuum 2 21 inHg 51 533 mmHg Flow 6 5 0 4 Ipm 11 8 inHg 300 mmHg Operating Temperature Range 50 F 104 F 10 C to 40 C Storage Transport Requirements Temperature Range 4 F to 104 F 20 C to 40 C Maximum Humidity 95 Non condensing Equipment Classification Class with respect to protection from electrical shock Type BF degree of protection against electrical shock IPXO degree of protection against ingress of liquids Mode of Operation continuous The Easy Go Vac Aspirator meets the EMC requirements of EN 60601 1 2 Specifications are subject to change without prior notice EASY GO VAG COMPONENT DESCRIPTION ACAUTION If for any reason any label becomes illegible or lost contact Precision Medical Inc
5. the following periods Easy Go Vac Aspirator Two 2 years from shipment Battery Six 6 months from shipment Should any failure to conform to this warranty appear within the applicable period Precision Medical Inc shall upon written notification thereof and substantiationthatthe goods have been stored installed maintained and operated accordance with Precision Medical Inc s instructions and standard industry practice and that no modifications substitutions alterations have been made to the goods correct such defect by suitable repair or replacement at its own expense ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES The representatives of Precision Medical Inc or any retailers are not authorized to make oral warranties aboutthe merchandise described in this contract and such statements shall not be relied upon and are not part of the contract for sale Thus this writing is a final complete and exclusive statement of the terms of that contract THIS WARRANTY ISEXCLUSIVE ANDIS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY WHETHER EXPRESS OR IMPLIED Precision Medical Inc shall not under any circumstances be liable for special incidental or consequential damages including but not limited to lost profits lost sales or injury to person or property Correction of non conformities as provided above shall constitute fulfillment of all liabilities
6. N 1 Steps 1 thru 4 see Operating Instructions on page 6 ACAUTION Battery should be fully charged before using to charge battery see Charging Battery When the yellow Low Battery Light is on continuously during normal use the battery needs to be charged f automatic shut off occurs during battery operation the Easy Go Vac Aspirator cannot be restarted until the battery has been recharged or until the Aspirator is connected to either of the external power source options 5 Push the On Off O Switch to the position If yellow Low Battery Light stays on continuously battery needs charging Charge battery or use another Mode of Operation AWARNING Operating Easy Go Vac Aspirator after yellow Low Battery Light has been on continuously will cause automatic shut down 6 Block the patient connection on the Suction Canister and adjust the Vacuum Control Knob to the desired vacuum To INCREASE vacuum Turn knob CLOCKWISE To DECREASE vacuum Turn knob COUNTERCLOCKWISE Vacuum should be set as prescribed by your Physician or Healthcare Professional 7 Connect one end of the Patient Suction Tubing to the port on the canister marked Patient Tubing 8 Connect the other end of the Patient Suction Tubing to the suction catheter and begin procedure as instructed by Healthcare Provider 9 When procedure is completed press the On Off O O Switch to the OFF position DO NO
7. T overfill the Canister 10 Empty the Suction Canister as follows Remove the canister from its bracket and empty as instructed by Physician or Healthcare Professional CAUTION Canister is single patient use only 11 Replace Suction Canister and reconnect all suction tubing C AUTO DC OPERATION Auto Power Port 1 Steps 1 thru 4 see Operating Instructions on page 6 a Insert small plug on the Auto DC Power Cord into the External Power Jack on the Aspirator b Plug the other end into the auto power port receptacle CAUTION DO NOT leave the Aspirator connected to the auto power port when not in use Failure to follow these instructions can cause severe battery failure and will VOID THE WARRANT Y see CHARGING BATTERY instructions 5 Push the On Off O Switch to the position If yellow Low Battery Light stays on continuously battery needs charging Charge battery or use another mode of operation AWARNING Operating Easy Go Vac Aspirator after yellow Low Battery Light has been on continuously will cause automatic shut down 6 Block the patient connection on the Suction Canister and adjust the Vacuum Control Knob to the desired vacuum To INCREASE vacuum Turn knob CLOCKWISE To DECREASE vacuum Turn knob COUNTERCLOCKWISE e Vacuum should be set as prescribed by your Physician or Healthcare Professional EASY GO VAC 9 7 Connect one end of the Patient Suction
8. Tubing to the port on the canister marked Patient Tubing 8 Connect the other end of the Patient Suction Tubing to the suction catheter and begin procedure as instructed by Healthcare Provider 9 When procedure is completed press the On Off O O Switch to the OFF position DO NOT overfill the Canister 10 Empty the Suction Canister as follows Remove the canister from its bracket and empty as instructed by Physician or Healthcare Professional CAUTION Canister is single patient use only 11 Replace Suction Canister and reconnect all suction tubing CHARGING BATTERY 1 Insert small plug on cord from the Battery Charger Power Supply into External Power Jack on the Easy Go Vac Aspirator 2 Connect the female end of AC Power Cord into the Battery Charger Power Supply 3 Plug male end 3 prong plug into a grounded receptacle Amber light on Battery Charger Power Supply will come on When amber light changes to green battery is fully charged Average charging time is 2 4 hours A new battery may take longer to fully charge the first time Note No damage will occur if the charger is left connected 4 Disconnect AC Power Cord from AC receptacle Disconnect cord from External Power Jack on Aspirator When fully charged battery will provide approximately 120 minutes of operation in 8 15 minute intermittent duration periods CLEANING MAINTENANCE AWARNING Turn the Easy Go Vac Aspirator
9. ac Aspirator from packaging and inspect for damage If there is any damage DO NOT USE and contact your Equipment Provider INTENDED USE The Easy Go Vac Aspirator provides a portable AC DC powered medical vacuum source It is intended for use in the homecare healthcare environment READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Easy Go Vac Aspirator This is provided for your safety and to prevent damage to the Easy Go Vac Aspirator If you do not understand this manual DO NOT USE the Easy Go Vac Aspirator and contact your Equipment Provider EXPLANATION OF ABBREVIATIONS mmHg Millimeters of Mercury inHg Inches of Mercury kPa Kilopascal lpm Liters per Minute EASY GO VAC SAFETY INFORMATION WARNINGS AND CAUTIONS DANGER AWARNING ACAUTION CAUTION i O o Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Used withoutthe safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CONSULT ACCOMPANYING DOCUMENTS Type BF equipment Suction OFF Battery Charging mode when plugged into charger
10. both ends of cord Connect to a known working auto power port Contact your Equipment Provider Continued on the next page EASY GOS VAC 12 Problem Probable Cause Remedy Battery will not charge Not connected to Defective Battery Defective battery Battery Charger Power Supply Charger Power Supply Connect Battery Charger Power Supply Contact your Equipment Provider Contact your Equipment Provider Unable to adjust vacuum 4 A Filter assembly Suction Canister Filter clogged Defective Suction not connected properly not connected properly Canister Defective Easy Go Vac Aspirator 3 4 Confirm and tighten connections Confirm and tighten connections Replace filter assembly Replace Suction Canister 5 Contact your Equipment Provider REPLACEMENT PARTS Description Part Filter 502438 Filter Assembly 503293 800cc Canister Case 10 ea 502519 10 Patient Suction Tubing 1955 Charger 503974 Carry Bag 502956 AC Power Cord 65 503106 Auto DC Power Cord 502954 355 55 2 EN ED WARRANTY AND LIMITATION OF LIABILITY Precision Medical Inc warrants that EASY GO VAC Aspirator the Product and the following component parts thereof will be free of defects in workmanship and or material for
11. o limitations on the validity of the declaration of conformity www precisionmedical com ISO 13485 Certified c 502598 Rev7 E 01 05 07 Printed in USA
12. of Precision Medical Inc whether based on contract negligence strict tort or otherwise Precision Medical Inc reserves the right to discontinue manufacture of any product or change product materials designs or specifications without notice Precision Medical Inc reserves the right to correct clerical or typographical errors without penalty DECLARATION OF CONFORMITY Manufacturer Precision Medical Inc 300 Held Drive Northampton PA 18067 USA CONTACT Quality Manager Phone 610 262 6090 Authorized European Representative Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands Product Easy Go Aspirator Model s PM65HG PM65E MDD Class lla Classification criteria Clause 3 1 Rule 11 of Annex IX of MDD As delivered the object of the declaration described above is in conformity with the requirements of MDD 93 42 EEC Annex II 3 and the following documents Document Title Edition MDD EEC 93 42 Council Directive Concerning Medical Devices 1993 BS EN 60601 1 Medical Electrical Equipment General requirements 1990 for safety BS EN 60601 1 2 Medical Electrical Equipment Collateral Standard 2002 Electromagnetic compatibility EN ISO 10079 1 Medical Suction Equipment Part 1 Electrically 2000 Powered Suction Equipment Safety Requirements EN 1441 Risk Analysis 1998 Notified Body TUV Rheinland Products Safety GmbH CE 0197 EC Certificate No HD60002285 SY60008447 74 500 2415 There are n
13. off and disconnect from any external power source before cleaning DO NOT clean the Easy Go Vac Aspirator with Alcohol Acetone or other solvents Inline Hydrophobic Filter This filter cannot be cleaned If it becomes contaminated or clogged it must be replaced To replace Inline Hydrophobic Filter 1 Disconnect filter assembly from Suction Canister and remove Suction Canister from the Aspirator 2 Unscrew filter assembly from the Aspirator 3 Dispose of filter 4 Install new filter Part 502438 by screwing filter into the Aspirator until hand tight Then reconnect tubing and elbow CAUTION DO NOT use sealing material on the filter threads Tubing is single patient use only DO NOT clean Easy Go Vac Case Use a cloth or sponge dampened with soap and water Wipe dry with a clean cloth or paper towel RETURNS Returned products require a Returned Goods Authorization RGA number contact Precision Medical Inc All returns must be packaged in sealed containers to prevent damage Precision Medical Inc will not be responsible for goods damaged in transit Refer to Precision Medical Inc Return Policy available on the Internet www precisionmedical com DISPOSAL INSTRUCTIONS Dispose of Bio waste products as described by your Healthcare Professional or Healthcare Facility protocol AWARNING The Easy Go Vac Aspirator contains a sealed lead acid battery DO NOT dispose with normal trash C
14. onsult your local waste management authority for proper disposal procedures f Aspirator is used for treatment of infectious disease consult your Physician or Healthcare Professional for recommended procedures for proper disposal Please Recycle 9 TROUBLESHOOTING If the Easy Go Vac Aspirator fails to function consult the Troubleshooting Guide There are no user serviceable parts inside DO NOT open case If the problem cannot be corrected consult your Equipment Provider TROUBLESHOOTING GUIDE Problem Probable Cause Remedy Easy Go Vac 1 On Off Switch 1 On Off Switch Aspirator will in OFF position to ON position not operate on battery 2 Battery not charged Low battery light on 2 Recharge battery If battery will not charge contact your Equipment Provider Easy Go Vac 1 On Off Switch 1 On Off Switch Aspirator will not in OFF position to ON position operate when 2 AC Power Cord 2 Check connection connected to AC connected at both AC Power Power Source Source and Aspirator Easy Go Vac 1 On Off O O Switch 1 On Off Switch Aspirator will not in OFF position to ON position operate when 2 Auto DC Power 2 Check connections connected to Auto DC Power Cord Cord not connected properly 3 Defective auto power port receptacle 4 Defective Auto DC Power Cord at
15. t the Inline Hydrophobic Filter This will void the warranty 4 Select appropriate Mode of Operation A AC ELECTRICAL RECEPTICLE OPERATION 100 240 Volts AC a Insert the small plug on the cord from the Battery Charger Power Supply into External Power Jack on the Easy Go Vac Aspirator b Connect the female end of the AC Power Cord into the Battery Charger Power Supply c Plug the male end 3 prong plug into a grounded receptacle Push the On Off Switch to the ON position Block the patient connection on the Suction Canister and adjust the Vacuum Control Knob to the desired vacuum To INCREASE vacuum Turn knob CLOCKWISE To DECREASE vacuum Turn knob COUNTERCLOCKWISE Vacuum should be set as prescribed by your Physician or Healthcare Professional Connect one end of the Patient Suction Tubing to the port on the canister marked Patient Tubing Connect the other end of the Patient Suction Tubing to the suction catheter and begin procedure as instructed by Healthcare Provider 9 When procedure is completed press the On Off Switch to the OFF position e DO NOT overfill the Canister 10 Empty the Suction Canister as follows Remove the canister from its bracket and empty as instructed by Physician or Healthcare Professional CAUTION Canister is single patient use only 11 Replace Suction Canister and reconnect all suction tubing B INTERNAL BATTERY OPERATIO