1. e Low Duty Cycle Data Acquisition mode LDCDA the data acquisition is immediately transmitted by radio The transmission frequency can be configured from 1s to 24h e Alarm Mode the measured value is transmitted by radio whenever an alarm threshold fixed by the user is detected 4 alarms threshold levels High Low e Survey Mode operates like the Alarm mode but the device sends frequently a beacon frame informing its current status BeanScape Premium Add on The BeanScape Premium integrates an OPC DA server Data Access OPC DA is particularly well suited for real time measurement and data sharing Each data measurement can be associated to a tag or its attributes and shared with one or many OPC clients TAF FBI HA RI EI ps ps ee ee eee For further information about the different data acquisition modes TN RF _ 008 Data acquisition modes available on the BeanDevice RETHINKING SENSING TECHNOLOGY Wanair a a BeanDevice AN 420 VERSION SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS TENDER iii Process CONFIGURABLE SENSOR POWER SUPPLY The sensor is directly powered by a high accuracy and adjustable DC DC converter integrated inside the device The excitation voltage is remotely configurable through the BeanScape 4 5 to 20V Sensor Power supply 4 5 to 20V Se Sensor Signal 4 20 mA SI EASY BATTERY MAINTENANCE Fully designed for an easy
2. PRahdevice SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS AN 420 VERSION TENDER BEI Process SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS 7 E ntevice renger e Z a R SE Cat Duef r yD 14 6 cm a made Se A Germany 3 35 cm M h MAIN FEATURES N Wireless data logger with 4 20mA current loop inputs 4 channels Wireless transmission IEEE 802 15 4 with antenna diversity o L d Integrated sensor power supply software configurable 4 5V to 20V FEATURED VIDEO BeanDevice AN 420 Xtender Main presentation Video USER MANUAL O BeanDevice ProcessSensor user manual MECHANICAL DRAWING O BeanDevice AN 420 Xtender drawing Integrated Lithium thionyl chloride primary cell 6 5Ah Embedded data logger up to 1million data points Extended operating temperature range 40 C to 85 C RETHINKING SENSING TECHNOLOGY We nAir AN 420 VERSION TENDER Sc Pade cal s m a f Wi ee 3 SEA JE EU W a z EMBEDDED DATA LOGGER UP TO 1 MILLION DATA POINTS The BeanDevice AN 420 Xtender integrates an embedded data logger which can be used to log data when a Wireless Sensor Networks can not be easily deployed on your site All the data acquisitions are stored on the embedded flash and then transmitted to the BeanGateway whenever a Wireless Sensor Network is established The Datalogger f
3. battery maintenance BeanDevice AN 420 Xtender integrates a battery holder which is sealed to IP67 extending the applications into harsher external environments where dust or water would inhibit equipment operation A RETHINKING SENSING TECHNOLOGY Wa all a DS BeanDevice AN 420 VERSION SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS TENDER us Process DT eem Product Reference BND AN420 XTD NCH N Number of data acquisition channels Example BND AN420 4CH 4 4 channels BeanDevice AN 420 with four channels Analog data acquisition block specifications Signal Conditionning Analog current loop measurement Number of channels 4 Channels A D Converter 16 bits SAR Architecture Successive Approximation Register with temperature compensation Measurement range 4 20 mA Current Loop measurement Non linearity error 0 5 LSB Measurement accuracy 25 C lt 0 08 when operating on battery power Sensor Connector M12 5Pins coming with an IP rating IP67 Nema 6 Caption Pwrt 2 Sens Pwr sensor power supply 4 5 to 20 Volts connected Gnd electrical ground Sens sensor signal input Sens Not used 4 Sens A Gnd Sensor Power Supply specifications Excitation voltage range 4 5 Volts to 20Volts configurable from the BeanScape software Excitation voltage accuracy on full 0 1 scale range 25 C Maximum Output Power 25 C 2 Watts Over the ai
4. n r age Preemie af pea nAir Rethinking Sensing Technology gan a LN WW WON Ae BeanGateway Indoor Version eanDevice BeanScape AN 420 Xtender v CERS a AE r eaa fi BeanGateway Dubdoor Version h Product specifications are subject to change without notice Contact Beanair for latest specifications eg RETHINKING SENSING TECHNOLOGY Wa nAir PR ahDevice AN 420 VERSION TENDER did Process SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS rr FOR MORE INFORMATION sales beanair com Visit our website www beanair com Visit our blog www industrial wsn com OUR YOUTUBE CHANNEL You Watch our featured videos on Youtube ee VISIT OUR WEBSITES pn weer ooo e mel a o Seeeeeeeeeeeeeeeeeeeeeseeeeeseeeeeseeseeeeeseeeeeseeeeeeseeeeeseeeeeeeeeeeeeeeeeeeeseeeeeeseeeeeseeeeeeeeseeeeeseeeeeseeeeeeeseeeeeeseeeeeseeeeeeseeeeeeeeeeeeeseeeeeeeseeeeseeeeeeseeeeeseeeeeeeeseeeeeseeeeeeeeeeeeeseeeeeee VISIT US a RETHINKING SENSING TECHNOLOGY Wa nAir
5. r configuration OTAC parameters Data Acquisition mode e Low Duty Cycle Data Acquisition LDCDA Mode 1s to 24 hour e Alarm amp Survey mode 1s to 24 hour Alarm Threshold 2 high levels alarms amp 2 low levels alarms Sensor power supply 4 5 to 20 Volts Power Mode Sleeping Sleeping with Network Listening amp Active TX Power 7 dBm 1 dBm 5 dBm 11 dBm 15 dBm 18 dBm RETHINKING SENSING TECHNOLOGY Wma nAir PR ahpevice AN 420 VERSION SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS SA Wireless Protocol Stack IEEE 802 15 4 2006 version WSN Topology Point to Point Star Data Rate 250 Kbits s RF Characteristics ISM 2 4GHz 16 Channels TX Power 0 dBm to 18 dBm Receiver Sensitivity 95 5 dBm to 104 dBm Maximum Radio Range 1 Km L O S Antenna diversity 2 omnidirectional N Type antenna gain of 2 2 dBi IP67 Nema 6 Embedded DataLogger Storage Capacity up to 1 million data points Wireless data dowloading 3 minutes to download the full memory average time Le Enclosure Aluminum Watertight IP65 Fire Protection ULV94 Getex Enclosure dimensions without antenna L x W x H 149 1 mm x 77mm x 60 5 mm Weight 690 g Shock Resistance 10g during 50ms Operating Temperature 40 C to 85 C Norms CE Labelling Directive R amp TTE Radio ETSI EN 300 328 ROHS Directive 2002 95 EC Power Supply Current consumption 3 3V During data acquisition 7OmA to 130mA depends on external
6. sensor power supply During Radio transmission 60 mA 0dBm During sleeping lt 30 pA Primary cell protection High precision primary cell monitoring Overvoltage Protection Overcurrent Short Circuit Protection Undervoltage Protec tion Primary cell Temperature monitoring Current accumulation measurement Primary cell Lithium thionyl chloride 6 5Ah Calibration Certificate Calibration certificate linked to national and international standards COFRAC RETHINKING SENSING TECHNOLOGY Wa nAir 2 A BeanDevice AN 420 VERSION SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS TENDER AA Process GETTING STARTING WITH A WIRELESS SENSOR NETWORK DESCRIPTION STARTERKIT REFERENCE Starterkit Wireless System acquisition BeanDevice AN 420 Xtender x BeanGateway Ethernet Indoor version Ref BGTW ETH IND 1 x BeanDevice AN 420 Xtender Ref BND AN 420 4CH XTD SK_BND_AN420_XTD_4CH_IND 1 x Beanscape Basic Ref BNSC BASIC Starterkit Wireless System acquisition BeanDevice AN 420 Xtender x BeanGateway Ethernet Outdoor version Ref BGTW ETH OUT ae pin A Sar A OUT 1 x BeanDevice AN 420 Xtender Ref BND AN 420 4CH XTD oL 1 x Beanscape Basic Ref BNSC BASIC The BeanDevice AN 420 Xtender operates only on our Wireless Sensor Networks you will need the BeanGateway and the BeanScape for starting a wireless sensor networks OO em SS SIDEC server is oly on the Ba
7. unction is compatible with all the data acquisition mode available on your BeanDevice AN 420 Xtender e LowDutyCycle Data Acquisition e Alarm e Survey EXAMPLE DATA ACQUISITION SYSTEM ON WATER TREATMENT PLANT e The BeanDevice AN 420 Xtender is configured with its Datalogger feature A standalone installation of the BeanDevice AN 420 Xtender will be done mounted on the walls without the necessity for any connection to the BeanGateway e Once the sensors are connected each data is recorded on the embedded flash e When needed a technician working on the site can send a request for a log transmission Then the BeanDevice AN 420 Xtender starts sending all its logs If all the logs are sucessfully transmitted to the BeanGateway the flash memory is erased and new logs will be recorded mm BeanDevice BeanGateway AN 470 Xtender LWSN Coordinator D i ee to kl G E re 8 a ie BeanDevice AN 420 VERSION SELF POWERED WIRELESS DATA LOGGER WITH 4 20MA CURRENT LOOP INPUTS TENDER Uk Process REMOTE CONFIGURATION amp MONITORING BeanScape Basic The BeanScape application allows the user to view all the data measurements transmitted by the BeanDevice AN 420 Xtender With the OTAC Over the Air configuration feature the user can remotely configure the BeanDevice AN 420 Xtender SEVERAL DATA ACQUISITION MODES ARE AVAILABLE ON THE BEANDEVICE AN 420 XTENDER