SEP Sensor Suite Commanding and Users Manual
Contents
1. SEPT NS PLASTIC IMPACT Boom IMPACT Boom MAG gt Figure 2 2 IMPACT locations on STEREO 2 1 SEP Interfaces to the IMPACT IDPU and the Spacecraft The IMPACT IDPU provides the interface between the STEREO Spacecraft C amp DH system and the IMPACT and PLASTIC Instruments including SEP All information transfer between the IMPACT PLASTIC instruments and the Spacecraft Ground flows through the IDPU including telemetry commands and status SEP communicates with the IDPU over a dedicated serial interface as described in reference 7 The SEP sensors and SEP Central are designed to be relatively autonomous Once their look up tables have been loaded and their modes and parameters set they will cycle through their data collection automatically and provide data to the IDPU without handshaking 3 SEP Instrument Power on and Boot Procedures The LET HET and SIT processors will power on whenever SEP Central powers on After power on the LET HET and SIT processors will execute a small boot loader program stored in the processor FPGA This boot loader will manage the reception and execution of boot code received from SEP Central on the serial command link After SEP Central boots the process of booting LET HET and SIT begins via a command from the GSE After the sensor boot command is received SEP Central begins the process of transferring boot code from SEP EEPROM to the LET HET and SIT processors over th
2. IMPACT SEP Users Manual Page 8 STEREO CIT 007 J As an example the sequence of events that occurs when a binary data command message for HET is sent to SEP Central is outlined below The sequence is the same for SIT There are currently no binary commands defined for LET 1 SEP Central encounters the HET BIN routing command indicating the beginning of a command message for HET 2 SEP Central initializes the serial command link with HET 3 SEP Central sends a short ASCII command to HET consisting of the CR character This elicits a short response from HET the HET prompt see section 4 3 below 4 SEP Central sends an ASCII command binary CR to HET to put HET in the correct mode for receiving binary data SEP Central reads the 16 bit byte count in the binary command message 6 SEP Central routes the byte count and the next N characters it receives from the IDPU to LET 7 SEP Central maintains the serial command link with HET in order to receive any responses from HET until it receives the command message termination character 0x03 As in the ASCII command message delay characters can be inserted into the message before the command message termination character to allow time for HET to transmit a response Nn 4 3 SEP Command Responses SEP Central buffers all command responses and transmits them to the IDPU in SEP command response CCSDS telemetry packets SEP command response CCSDS telemetry packets are assigne
3. MOC over the Internet using Secure Shell SSH and other security measures The POCC to MOC interface is described in reference 16 The operation of the IMPACT POCC is described in reference 18 The SEP GSE communicates with the IMPACT POCC over the Internet using Secure Shell SSH and other security measures The SEP GSE to IMPACT POCC interface is described in references 16 and 18 Figure 3 1 shows a block diagram of the interfaces between the SEP sensor GSEs the SEP GSE the IMPACT POCC IMPACT GSE the STEREO IMPACT SEP Users Manual Page 16 STEREO CIT 007 J IMPACT IDPU onboard the spacecraft and the SEP sensor suite For simplicity MOC and spacecraft interfaces are not shown Commanding capabilities that are disabled after delivery of the SEP suite to APL are marked with a red X Telemetry TCP IP a Command Messages IMPACT X GSE TCP IP LET Displays Telemetry Telemetry Dita x IMPACT IDPU Commands Command Telemetry Messages TCPAP IMPACT IDPU VF Telemetry Command Telemetry Command Telemetry Messages Messages g Command Messages SEPT SIT HET GSE GSE GSE Figure 3 1 IMPACT locations on STEREO The SEP GSE performs the following functions e Commanding of the SEP sensor suite prior to delivery of the SEP suite to APL via the IMPACT POCC interface e Telemetry Socket Server providing SEP telemetry to other networked clients SEP sensor GSEs e Display of SEP housekeeping and status data o Real t
4. STE U SWEA STE D and SEP plus one to PLASTIC These are controlled by the spacecraft and the Mission Operations Center and cannot be controlled directly by the POCC However the IDPU can request that one or more of these systems be powered off in response to an error condition and the POCC can trigger such a request via command to the IDPU Typically when an instrument is powered off the spacecraft powers its survival heater on SEP has several survival heaters SEP also has a number of operational heaters powered via the SEP power service and controlled by SEP Central The spacecraft controls most of the IMPACT actuators directly including SIT and SEPT one time cover actuators The IDPU and POCC cannot control these actuators it must be done by the MOC The spacecraft also has 9 temperature sensors that it monitors in the IMPACT suite These sensors are the only telemetry we get when the IDPU is off The data from these sensors is part of the spacecraft telemetry not the IMPACT telemetry and will not be available to the POCC in real time it will be part of the spacecraft status data provided non real time to the POCC Likewise the current monitors on the spacecraft power services is Spacecraft telemetry STEREO IMPACT SEP Users Manual Page 20
5. detector bias voltages BANKCP Copies from eeprom bank 0 to bank 1 STEREO IMPACT SEP Users Manual Page 11 STEREO CIT 007 J LET Commands ADCMODE Disables live stim events in favor of adc stim events only Allows for faster collection of a complete ADC calibration data set THRMODE Similar to ADCMODE but the range of calibration DAC is reduced to focus on the threshold regions NORMAL Undoes ADCMODE or THRMODE to place instrument back into normal operation in which both live stim and adc stim events are produced at a rate near 3 per second QUIET Disables both live stim and adc stim events HERE Verifies the address at the end of FORTH dictionary in LET memory TIME Displays elapsed time in hr min sec sub sec since the last LET boot 30 TEMPGOAL Raises LET op heater set point to 45 C facilitates verification of functionality at room temperature and in hot T V soak 230 TEMPGOAL Lowers set point to 40 C facilitates verification of functionality in cold T V soak 157 TEMPGOAL to return set point to 10 C flight default 50000 STIMPER Raises LET stim pulser rate to 4 per second 100000 STIMPER Returns LET stim pulser rate to 2 per second flight default 0 FCULL Turns off culling of cross talk hits in telemetered events 1 FCULL Turns on culling of cross talk hits in telemetered events flight default HGT Prints out high gain thresh settings of 54 channels in 64 ch array STEREO IM
6. may be packed into a telecommand packet ASCII commands for SEP Central may span telecommand packets but this is not recommended See section 4 2 1 3 Note again that SEP Central executes commands that affect SEPT NS and or SEPT E 4 2 1 2 ASCII Data Command Messages for HET LET SIT If a command message is destined for HET LET or SIT then SEP Central initializes the multiplexed serial command link to the appropriate sensor based on a routing command contained in the command message and forwards the command to the appropriate sensor ASCII data command messages for LET HET SIT consist of ASCH Commands defined in section 4 2 1 above preceded by a routing command and followed by the command message termination character 0x03 Note that the routing command is itself an ASCII command that is executed by SEP Central Neither the routing command nor the command message termination character is passed on to the sensors The message format is summarized in Table 4 1 below Table 4 1 ASCII Data Command Message for HET LET SIT Length Item bytes Description Routing command string XXX HET XXX CMD 7 LET or SIT gt ASCII CR This terminates the routing command Routing Cmd 0x0D 1 that is interpreted by SEP Central ASCII Commands X A series of ASCII commands as defined in section 4 2 1 0x03 1 Command message termination character not passed on 9 X Total Length of ASCII Command Message As mentioned before an ASCI c
7. Al documents can be found on either the Berkeley STEREO IMPACT FTP site or the Caltech STEREO SEP ftp site http sprg ssl berkeley edu impact dwe ftp mussel srl caltech edu pub stereo docs 1 STEREO CIT 001 STEREO CIT 002 LET and SEP Central Software Development Plan and Software Requirements docs 2 HET Software Development Plan and Software Requirements docs 3 SIT Software Development Plan and Software Requirements docs 4 SEPT Operation Control and Data Processing Requirements 5 STEREO CIT 012 SEP GSE Software Development Plan 6 STEREO CIT 005 P24 MISC processor manual 7 IMPACT Intra Instrument Interface ICD 8 STEREO CIT 009 LET SEP_ Central ICD 9 STEREO CIT 008 HET SEP_ Central ICD 10 STEREO CIT 010 SEPT SEP_ Central ICD 11 STEREO CIT 011 SIT SEP_ Central ICD 12 STEREO CIT 001 P24 MISC G buss I O Interface Document TBD Caltech WRC 13 STEREO CIT 003 LET HET and SIT Science Data Frame Format Specifications 14 SEPT FPGA Data Sheet 15 IMPACT Spacecraft ICD 16 ICD MOC POC_ICD MOC to POCC ICD 17 ICDAMPACT CTM B IMPACT Command amp Telemetry database 18 TBD POCC Users Manual 19 Specifications CmdFmt IMPACT IDPU Command Formats 20 STEREO CIT 016 SEP Housekeeping packet format Spec STEREO IMPACT SEP Users Manual Page 1 STEREO CIT 007 J 1 3 Acronyms ACE Advanced Composition Explorer API Application Programming Interface ApID Application Process Identifie
8. Central Commands ALLONI1 Boot LET HET and SIT and initiate normal operations of SEPT for flight unit 1 ALLON2 Boot LET HET and SIT and initiate normal operations of SEPT for flight unit 2 14000 HET BOOT Boot HET 21000 SIT BOOT Boot SIT 47000 LET BOOT Boot LET INITPCHK Initialize checksums for eeprom INITRCHK Initialize checksums for ram PCHKS Echo eeprom checksums RCHKS Echo ram checksums STEREO IMPACT SEP Users Manual Page 10 STEREO CIT 007 J PROMOK Echo value of PROMOK variable 1 gt no change in checksum since most recent INITRCHK 0 gt a change in checksum since most recent INITRCHK CODEOK Echo value of CODEOK variable 1 gt no change in checksum since most recent INITRCHK 0 gt a change in checksum since most recent INITRCHK SEP BIN Initiates binary upload to SEP Central for detailed format info see above HET BIN Initiates binary upload to HET SIT BIN Initiates binary upload to SIT xxx HET gt PROM Writes into HET image block xxx in eeprom following SEP BIN only if SEP BIN checksum ok xxx SIT gt PROM Writes into SIT image block xxx in eeprom following SEP BIN only if SEP BIN checksum ok xxx LET gt PROM Writes into SIT image block xxx in eeprom following SEP BIN only if SEP BIN checksum ok PHVON Turns on the positive detector bias voltages NHVON Turns on the negative detector bias voltages PHVOFF Turns off the positive detector bias voltages NHVOFF Turns off the negative
9. PACT SEP Users Manual Page 12 STEREO CIT 007 J 374 32 HGTHRS Varies high gain threshold on L1B0a channel ch 32 in the array INITCHKS Re initializes LET checksums These are the only LET commands used routinely Significant other commanding capability exists for handling non routine conditions Specific command sequences to address non routine situations will be defined and tested on the LET EM unit prior to execution on any flight unit 5 SEP Telemetry Data Telemetry data generated by the SEP sensor suite falls into five categories science data housekeeping data beacon data fill data and command responses Command responses are described in section 4 3 above Except for beacon data SEP telemetry data are transferred to the IMPACT IDPU as CCSDS telemetry packets The packet ApID code defines the origin and content of these packets ApID codes are allocated to SEP as follows all numbers are decimal and all ranges are inclusive e Command Response 576 e SEP Combined Housekeeping 577 e LET science 580 587 e LET housekeeping 588 e LET beacon 589 e HET science 590 597 e HET housekeeping 598 e HET beacon 599 e SIT science 605 617 e SIT housekeeping 618 e SIT beacon 619 e SEPT science 600 601 e Fill Packet 623 e Spares 578 579 602 606 and 620 622 SEP sensors are free to define several different science packet types if they wish using their allocated science ApID codes Except for c
10. SEP Command RESPONSES sissccasscessosscsescseresssecesscevnsssuesscesssvosousnvsssoveucosesusevens 9 4 3 1 Format of SEP Command Responses cccsccssccesscsserssesncssecsstcessscees 10 4 4 SEP Command LISU cssskssssisccscscesssvctetsncsnvesvatacbossbesevdeschonsetvectevcobatncussncenysevatees 10 De SEP Telemetry Da tat a pscsssclacdidvssvesscascnswasdedasdcvawessscasceiivesoneusvasdatiecassoessveummeasvckosnetx 13 5 1 SEP Housekeeping Data sssiccceisestsscstssccesssvevssivasssesuessedevsviosesesenssvesanasereesvacaceass 14 5 2 SEP Beacon Datis a i 15 Dede SEP Science Data ssssessssssseessiisisessssssessostsesrasss soosis iese TEE ELEG E SEERE SELE sioe saisies 16 6 SEP Ground System eessoesssessseessooesoosssossssesssosssoossoossosssssesssoessoosesossssssssesssocssooses 16 6 1 Commanding of SEP from the IMPACT POCC sscccssccessscscssccsecsssesssesees 17 6 2 Commanding of SEP from the SEP GSE sccsssccsssscsssssssesssscesssssesssssessseees 18 6 3 Commanding Security sissesiessesesissercdiserssasesssssasssccenssecusdoroecsesussettoussssecsesievecedes 18 6 4 SEP GSE Telemetry Socket Server SOftware sscccssscccsssssessscsssscccssscssssssesees 19 6 5 Real Time Data Display ss coeudseieuveieivesvisstdusdacdyeaceesds 19 6 5 1 SEP GSB cesaron Geant sasieniy sbiade eavcbsecsauusaaatheusea tune bien A 19 6 5 2 Sensor GS Essi a thie gaat ah aie ahs chat es ola 19 6 6 Non Real time Data Analysis sc
11. STEREO CIT 007 J STEREO IMPACT SEP Sensor Suite Commanding and Users Manual SEP CommandingUserManual I doc Version J 2006 March Andrew Davis Andrew Davis STEREO CIT 007 J Document Revision Record Rev B Date Description of Change Approved By 2002 Oct 10 Preliminary Draft 2002 Oct 30 Incorporate Caltech and GSFC comments 2003 Jan 24 Update Section 5 ApIDs and Housekeeping pee a a Lt 2003 May 1 Update ApIDs fill packet ApID and expanded SIT ApID range Update discrete command details Insert SEP command message and command response formats Various minor updates to intro and overview sections is f ae en 2003 May 5 Incorporate comments from Bob Radocinski and Rick Cook 2003 May12 2003 June 2005 July 2006 March Distribution List Rick Cook Caltech SRL Alan Cummings Caltech SRL Andrew Davis Caltech SRL Branislav Kecman Caltech SRL Allan Labrador Caltech SRL Richard Mewaldt Caltech SRL Robert Radocinski Caltech SRL Ed Stone Caltech SRL Mark Wiedenbeck Caltech SRL Donald Reames GSFC Tycho von Rosenvinge GSFC Tom Nolan GSFC Bob Baker GSFC Kristin Wortman GSFC Dave Curtis UCB STEREO IMPACT SEP Users Manual Page i STEREO CIT 007 J Table of Contents Document Revision Record e ssessossesssescoeseesoesooesoesoesooesoesoossossseseoesoosseesoseoossossossoossossoseooe i Distribution Listisisssiesssssssesssericssescsssssssers
12. build time history plots 6 6 Non Real time Data Analysis The SEP GSE software will include non real time software for further data examination For SEP Central this software is limited to the examination of housekeeping For the LET GSE and the other sensor GSEs the non real time software will also include the ability to examine the science data For the LET GSE the non real time software will have e aset of IDL routines for generating a standard sets of plots from stored data e aset of IDL routines for accessing the stored data for reports monitoring long term trends examining unusual incidents The non real time software for the other sensor GSEs will have similar capabilities 6 7 Data Logging 6 7 1 SEP GSE The SEP GSE logs the following packets to disk as they are received STEREO IMPACT SEP Users Manual Page 19 STEREO CIT 007 J e All packets with any SEP Apld e IMPACT housekeeping packets that contain SEP housekeeping data e SEP command responses e Beacon data packets 6 7 2 Sensor GSEs The sensor GSEs also log to disk the packets and standard data structures reports plots etc that they create from the data 7 SEP GSE User Manual Here we will record all necessary instructions for running the SEP GSE when they are available TBD rgr 8 Other Services Provided to SEP by the Spacecraft The spacecraft provides three operational switched and current monitored power services to IMPACT IDPU Mag
13. csscccssssscssssecsssssccsssccccscsssscssscssssssssssssossees 19 6 7 Data Logging sssini suuwetibecussvuluctvuniysduessuluteriuniedecaseteans 19 6 7 1 S PUGS EPEAT T 19 6 7 2 Sensor GSES Snai i t a a ia aiaa 20 Te SEP GSE User Manu l sessscsecsssossssosesosesossonessssosossososs ssnsossssvosssesssesosese osi s dennes 20 8 Other Services Provided to SEP by the Spacecraft ssessseossoossooesosssssesssesesoose 20 9 SEP Constraints esseseesoseossesossossesoosessoseossesossossesesseese Error Bookmark not defined STEREO IMPACT SEP Users Manual Page ii STEREO CIT 007 J 1 Introduction The IMPACT SEP sensor suite consists of four sensors LET HET SEPT and SIT Four microprocessors are dedicated to controlling interfacing and acquiring data from these sensors This document describes how to run the SEP sensor suite after delivery to APL and during the mission referring to other documents as necessary This document also defines SEP commands command formats command response formats and SEP operational constraints 1 1 Document Conventions In this document TBD To Be Determined means that no information currently exists TBR To Be Resolved means that a statement is preliminary In either case the initials of the institutions persons responsible for providing the information typically follow the acronym 1 2 Applicable Documents The following documents are closely interrelated with this specification
14. d a unique ApID from the SEP ApID range see section 5 below The body of these command response packets is a container for raw command responses from the SEP sensors and SEP Central Command responses from the SEP sensors and SEP Central should generally be in human readable ASCII format This will ensure that the contents of SEP command response packets can be easily scanned by personnel on the ground and easily incorporated into command response logs Although command response messages do not count towards the SEP telemetry allocation Section 8 of the IMPACT Intra instrument Interface ICD reference 7 specifies that SEP may not exceed its telemetry allocation by more than two CCSDS packets over any 1 minute interval Therefore SEP Central must ensure that no more than two command response packets are transmitted to the IDPU each minute SEP Central achieves this by buffering command responses into a software FIFO Software running in SEP Central inspects this buffer at regular intervals and constructs command response packets from the contents at a rate of no more than two packets per minute Thus more than one command response may be packed into the same command response packet The software attempts to minimize latency for short command responses while the command response FIFO is sized to accommodate the largest command response generated by the SEP sensors Update to the above if during a given minute one or more of the SEP sensors gene
15. d by SEP Central The following routing command strings are defined although others may be added to the list e HET BIN Binary data for HET e HET BINC Compressed binary data for HET e SIT BIN Binary Data for SIT e SIT BINC Compressed binary data for SIT e LET BIN Binary data for LET e SEP BIN Binary data for SEP Central In binary command messages destined for HET LET SIT the function of the optional delay characters 0x00 following the CR character is to introduce a time delay before SEP Central receives the command message termination character Each pair of delay characters adds a 3 5 ms delay due to the delay inserted by the IMPACT IDPU see section 4 0 As in ASCII command messages these delays allow the sensor extra time to process the message and generate a response before SEP Central receives the command message termination character SEP Central does not absorb delay characters that may appear in the byte count the binary data or the checksum These parts of the message are passed on unmodified by SEP Central The length of a Binary command message is limited by the 16 bits allocated to the byte count However it is recommended that the length be limited so that the message fits within a single CCSDS telecommand packet max 1076 bytes of data The Byte order shown in the format is as the packet is created in the originating GSE We must work to understand and deal with any en route byte swapping that might occur STEREO
16. d for SEP ASCII and Binary 4 2 1 ASCII Data Command Messages These are generally used to change the mode of operation of SEP Central or one of the sensors We define here an ASCII Command to be a series of N printable characters with the Nth character being CR ASCH char 0x0D followed optionally by a series of M delay characters ASCII char 0x00 An ASCII command may NOT contain the command message termination character 0x03 which is interpreted by SEP Central to be the termination of a command message for HET LET SIT see section 4 2 1 2 below ASCII commands are used to build ASCII Data Command Messages as described below The function of the delay characters in ASCII commands is also described below 4 2 1 1 ASCII Data Command Messages for SEP Central ASCII data command messages destined for SEP Central consist of a series of ASCII Commands The delay characters are not necessary for ASCII data command messages destined for SEP Central i e M 0 The shortest ASCII command that can be sent to SEP Central N 1 and M 0 is simply the CR character ASCII char 0x0D This will elicit a response from SEP Central consisting of CRLF ASCII chars 0x0D and 0x0A followed by an ASCII prompt string See section 4 3 Command Responses below for prompt string definitions for SEP Central HET LET and SIT STEREO IMPACT SEP Users Manual Page 5 STEREO CIT 007 J More than one ASCII command for SEP Central
17. dessesoeis raos oseossesessstes sios s sese ssas rieuses soss ssiri i 1 Introduction seoses essens oseese isi asis 1 LL Document CONVENTIONS ws cccssinivssccivedesbeasisecovspinauceinivesueisstaauesbivdoveduindeceasseeaudsseaas I 12 Applicable Documents sccicssssesscsursadsurssecdusiasivessnusiescnietsncsesesibncuetaeenestsncbessavabsiies I LES MCTONPINS ESE EEE E SERENE E SEERNE SDS SEES SENSE E 2 Di EPO VOR 4 TO FREE ES EEN ESS SESEESSESES ESSENS SES SES SIESESSESE spass vsisi ss s siens 2 2 1 SEP Interfaces to the IMPACT IDPU and the Spacecraft seere 3 3 SEP Instrument Power on and Boot Procedures sccssscsssssssscssscssscsssseess 3 As SEP Commanding css ccnssassscensssisedssossetsestsscecossssessonessatconnssusssitssnendbesiianesatseticnsitacseans 4 4 1 Discrete Command Messages scccsscccsssccssscccssccccscscccsccccsccssssesscssccsssseessesees 4 4 2 Data Command MESSAGES soos ai iveney casas ssasauseyescsensssaipeseesaseidaseenieons asosio s sieo o ssi 5 4 2 1 ASCII Data Command Messages ccccccescssceeseeeteeceeceseeeeeeenseeesseeesaeens 5 4 2 1 1 ASCII Data Command Messages for SEP Central seere 5 4 2 1 2 ASCII Data Command Messages for HET LET SIT 0 eee 6 4 2 1 3 General Notes on ASCII Data Command Messages ceseeeseeerees 7 4 2 2 Binary Data Command Messages Table Loads 1 Wu Wu u u ssseeserrrrrerrerseee 7 4 2 2 1 Binary Data Command Messages for SEP Central and LET HET SIT 7 4 3
18. e must work to understand and deal with any en route byte swapping No checksum is provided in the ASCII data command message format 4 2 2 Binary Data Command Messages Table Loads These are generally used to update a region of RAM in SEP Central or one of the sensors 4 2 2 1 Binary Data Command Messages for SEP Central and LET HET SIT A Binary data command message consists of a routing command a 16 bit byte count N N 2 bytes of binary data a 2 byte checksum an optional series of delay characters 0x00 and a command message termination character 0x03 The message format is summarized in Table 4 2 below STEREO IMPACT SEP Users Manual Page 7 STEREO CIT 007 J Table 4 2 Binary Data Command Message Length Item bytes Description ASCII Routing Command M An ASCII Command used by SEP Central to route the message Byte cnt 0 MSB 1 A 16 bit Count of bytes that follow including the checksum N Byte cnt 1 LSB 1 Binary data N 2 N 2 bytes of binary data Chksum byte 0 MSB 1 A 16 bit value which when added to the N 2 bytes of binary Chksum byte 1 LSB 1 data makes the 16 bit sum 0 An optional series of delay characters 0x00 which will be Delay chars X absorbed by SEP Central and not passed on 0x03 1 Command message termination character not passed on M N X 3 Total Length of Binary Command Message The routing command is an ASCII command of even length with no delay characters that is interprete
19. e serial command link After power on SEP Central attempts to boot from page 0 of EEPROM Subsequently three different discrete reset commands can be sent to SEP The first causes SEP Central to boot from page 0 or EEPROM The second causes SEP Central to boot from page 1 of STEREO IMPACT SEP Users Manual Page 3 STEREO CIT 007 J EEPROM and the third causes SEP Central to accept boot code over the serial link to the IDPU 4 SEP Commanding Prior to delivery of the SEP suite to APL SEP command messages may originate at the IMPACT Payload Operations Control Center POCC the SEP GSE or at the sensor GSEs see section 5 below After APL delivery command messages destined for the SEP suite will enter into the STEREO command stream only at the IMPACT Payload Operations Control Center POCC The SEP team will control the SEP suite by instructing the IMPACT POCC to upload stored commands In any case at the point where they originate SEP command messages are contained in CCSDS telecommand packets which are themselves contained in Supplemented Command Messages SCMs as described in reference 16 During the mission commands are sent by the IMPACT POCC to the Mission Operations Center MOC then on to the spacecraft then to the IMPACT IDPU and finally to SEP Central Formulation of SEP commands on the ground is described in section 5 of this document The spacecraft forwards CCSDS telecommand packets contained with the SCMs withi
20. es 2 1 2 71 gt MESSAGE ID word 0x0847 SEP Central will send the Beacon message to the IDPU during minute N 2 in the interval between 0 and 6 seconds after the 1 minute sample tic The contents of the SEP housekeeping are defined in reference 20 5 3 SEP Science Data The SEP telemetry allocation for science data is as follows HET 6 272 byte telemetry packets min LET 16 272 byte telemetry packets min SEPT 2 272 byte telemetry packets min SIT 12 272 byte telemetry packets min The contents of the SEP housekeeping are defined in reference 20 During minute N 1 HET LET and SIT will each send packets of science data collected during minute N to SEP Central HET LET and SIT will format science data into 272 byte CCSDS packets using one of their allocated science ApIDs to identify the packet see section 5 0 During each minute the sensors shall transmit their science data packets to SEP Central AFTER they have transmitted their Housekeeping and Beacon packets Each sensor may send up to its allocation of science packets each minute If there was not enough science data collected by a sensor during a given minute to fill the science allocation the sensor may substitute fill packets ApID 623 for science packets SEP Central does not pass on fill packets to the IDPU 6 SEP Ground System The MOC controls the STEREO spacecraft The IMPACT POCC at Berkeley controls the IMPACT suite The IMPACT POCC communicates with the
21. ete command messages for SEP will use ApID 0x26F When the IMPACT IDPU receives a telecommand packet with ApID 0x26F it will generate exactly one 24 bit command word with address OxFF and containing the first 16 bits of the application data field of the telecommand packet and STEREO IMPACT SEP Users Manual Page 4 STEREO CIT 007 J one 24 bit command word with an address of 0x01 for each subsequent 16 bit data group in the telecommand packet see sections 7 3 and 7 4 of reference 7 The discrete command code is contained in the first 16 bits of the application data field of the telecommand packet The only discrete commands currently envisioned for SEP Central is are the Reset commands described above 4 2 Data Command Messages CCSDS telecommand packets containing Data Command Messages for SEP will use ApIDs in the range 0x260 0x26E inclusive When the IMPACT IDPU receives a telecommand packet within this range it passes the data in the application data field of the packet to SEP Central as described in section 7 4 of reference 7 Data command messages are passed on by the SEP Central hardware to software running in the SEP Central MISC for routing execution Data command messages that are destined for SEPT NS SEPT E or SEP Central are executed directly by SEP Central Data command messages destined for HET LET or SIT are routed by SEP Central to those sensors as described below Two classes of Data Command Messages are define
22. hould be spread out roughly evenly over the 60 second cycle Since LET HET and SIT are each allocated 20 windows per minute more than they need and more than their telemetry allocation some packets will be fill packets ApID 623 SEP Central does not forward fill packets to the IMPACT IDPU Since SEPT does not have its own processor the data transfer protocol is different for SEPT Data acquisition from the two SEPT telescopes electronic units is managed directly by SEP Central per reference 4 and SEP Central builds SEPT science data packets In general data packets collected from the sensors during minute N 1 by SEP Central contain data collected during the prior minute N and are transmitted to the IMPACT DPU during minute N 2 SEP Central fills in the UT portion of all packets received during minute N with the UT code associated with tic0 of minute N 1 i e the UT code of a packet will refer to the beginning of the minute during which it s data was accumulated SEP Central transmits telemetry packets to the IMPACT IDPU per the protocols in reference 7 5 1 SEP Housekeeping Data The SEP telemetry allocation for housekeeping data is 260 bytes minute the application data field of one 272 byte CCSDS telemetry packet minus the checksum byte e HET 41 bytes min e LET 102 bytes min e SEPT 26 bytes min STEREO IMPACT SEP Users Manual Page 14 STEREO CIT 007 J e SIT 36 bytes min e SEP Central 55 bytes mi
23. ime o Non real time e Logging of SEP data to disk 6 1 Commanding of SEP from the IMPACT POCC Commands destined for the SEP sensor suite may originate either at the IMPACT POCC or at the SEP GSE or at the SEP sensor GSEs After delivery of SEP to APL all SEP commands will originate at the IMPACT POCC Pre coded commands in the CCSDS telecommand format can be referenced by file name by the IMPACT POCC This scheme is the method that will be used by the SEP team to command the SEP sensor suite after delivery of the SEP sensor suite to APL and during the mission STEREO IMPACT SEP Users Manual Page 17 STEREO CIT 007 J 6 2 Commanding of SEP from the SEP GSE This section describes capabilities that will only be enabled prior to the delivery of the SEP sensor suite to APL All commands forwarded by the SEP GSE to the IMPACT POCC are in the form of CCSDS telecommand messages as described in reference 16 The SEP GSE software provides support for commanding from the SEP GSE keyboard using a terminal like program e The program allows the user to type any command on the SEP GSE keyboard On lt CR gt the command is sent e Monitors and displays any command responses Allows the user to send any stored command message on the SEP GSE using a simple keyboard command e If command forwarding is enabled and any remotely sent command message arrives while the terminal program is running the program will allow the user to either reject the c
24. l initializes the serial command link with LET 3 SEP Central sends a short ASCII command to LET consisting of the CR character This elicits a short response from LET the LET prompt see section 4 3 below 4 SEP Central routes subsequent characters it receives to LET except for delay characters 5 While SEP is receiving delay characters from the IDPU LET has extra time to execute commands it has received and to transmit command response characters 6 SEP Central encounters the command message termination character 0x03 and terminates the LET commanding mode initiated in step 2 Any command response characters transmitted by LET after this step will be lost After receipt of the command message termination character SEP Central interprets all subsequent command characters until another routing command is received 4 2 1 3 General Notes on ASCII Data Command Messages The length of ASCII commands should be an even number up to and including the CR It is recommended that the space character 0x20 be used before the CR character to pad the length out to an even number of bytes including the CR character The length of an ASCII command message is limited only by the limits on the length of SCMs However it is recommended that the length be limited so that the command message fits within a single CCSDS telecommand packet max 1076 bytes of data Byte order shown in the format is as the packet is created in the originating GSE W
25. l that is used to send command messages between the IMPACT POCC and the MOC Command messages from the SEP GSE to the IMPACT GSE will use the same SSH 2 protocol STEREO IMPACT SEP Users Manual Page 18 STEREO CIT 007 J Post delivery the default state will be that SEP commands will enter the command stream at the IMPACT POCC not at the SEP GSE or the SEP sensor GSEs The SEP team will provide commands to the IMPACT POCC via a separate secure channel 6 4 SEP GSE Telemetry Socket Server Software e The SEP GSE will act as a socket server that will provide telemetry to the telescope GSEs e Upto 12 TCP IP connections e The following telemetry packets will be forwarded over the socket connections o All science packets with any SEP ApID o SEP housekeeping packets o SEP command response packets o Beacon data packets with SEP data 6 5 Real Time Data Display 6 5 1 SEP GSE The SEP GSE provides real time displays of SEP housekeeping data SEP temperatures voltages currents etc 6 5 2 Sensor GSEs The following is based on the LET GSE Other SEP sensor GSEs perform similar functions e Filter the packets from the SEP telemetry that contain LET data e Build a set of standard data structures from the LET data e Build a standard set of real time page displays for the information in the standard structures may have more than one type of page display per structure e Allow the user to select variables from the page displays to
26. n The contents of the SEP housekeeping are defined in reference 20 During minute N 1 HET LET and SIT will each send a packet of housekeeping data collected during minute N to SEP Central HET LET and SIT will format housekeeping data into CCSDS packets using one of their allocated ApIDs to identify the packet see section 5 0 Each sensor will send one housekeeping packet once per minute HET LET and SIT will send their housekeeping data packets to SEP Central during the first window available to them each minute Thus HET will always send its HK packet during tick 0 and SIT will always send its HK packet during tick 1 and LET will always send its HK packet during tick 2 This allows for simplification of software in SEP Central Housekeeping data from HET LET and SIT should be positioned at the beginning of the housekeeping packets sent by those sensors to SEP Central During minute N 1 SEP Central will receive HK CCSDS packets from the HET LET and SIT sensors At the beginning of N 2 SEP Central will combine HK packets from HET LET and SIT with HK data gathered from SEPT and from the SEP common electronics all of the data having been collected during minute N on each sensor into a common SEP HK CCSDS packet The format of this packet is described in reference 20 SEP Central will send the common SEP HK packet to the IDPU during minute N 2 per the protocols in reference 7 5 2 SEP Beacon Data The SEP telemetry allocati
27. n the IMPACT or PLASTIC ApID range Application Identifier a code in the CCSDS packet header to the IMPACT IDPU see reference 15 and 16 The allocation of ApIDs to SEP is defined in reference 19 The IMPACT IDPU forwards the Application Data Field of telecommand packets with ApIDs within the SEP ApID range to SEP Central i e the IMPACT IDPU strips off the CCSDS packet headers SEP Central receives command messages from the IMPACT IDPU as a series of 24 bit command words as described in reference 7 The SEP team has requested and the Berkeley IMPACT team has agreed that there will be a delay of at least 3 5 ms between each 24 bit command word sent from the IMPACT IDPU to SEP Central The SEP team imposes a requirement upon itself that the Application Data Field of SEP telecommand packets shall contain an even number of bytes However if the IMPACT IDPU detects a SEP telecommand packet with an odd number of bytes in the application data field it will pad the number of bytes out to an even number before forwarding to SEP Central The pad byte used by the IDPU is currently the space character 0x20 SEP Central routes command messages to the appropriate SEP sensors based on routing information contained in the messages as described below 4 1 Discrete Command Messages Discrete commands are recognized by hardwired logic in SEP Central Discrete commands are also executed by the hardwired logic CCSDS telecommand packets containing discr
28. ommand may NOT contain the command message termination character 0x03 which is interpreted by SEP Central to be the termination of a command message for HET LET SIT In ASCII commands destined for HET LET SIT the function of the optional delay characters 0x00 following the CR character is to introduce time delays between ASCII commands transmitted by SEP Central to the sensor and also a delay before SEP Central receives the command message termination character Each pair of delay characters adds a 3 5 ms delay due to the delay inserted by the IMPACT IDPU see section 4 0 Delay characters in ASCII commands are absorbed by SEP Central and are not passed on to the sensors As part of execution of the routing command SEP Central will send a short ASCII command consisting of the CR character to the appropriate sensor This will elicit a response from the sensor consisting of CRLF ASCII chars 0x0D and 0x0A followed by an ASCII prompt string See section 4 3 Command Responses below for prompt string definitions for SEP Central HET LET and SIT STEREO IMPACT SEP Users Manual Page 6 STEREO CIT 007 J As an example the sequence of events that occurs when an ASCII data command message for LET is transmitted to SEP Central by the IMPACT IDPU is outlined below The sequence is the same for HET and SIT 1 SEP Central encounters the LET CMD routing command indicating the beginning of an ASCII command message for LET 2 SEP Centra
29. ommand message or allow it to be sent The SEP GSE software provides support for sending command messages stored on its disk to SEP e The programs are stored in a variant of the standard CCSDS command messages that use relative times instead of absolute times e Ifthe command message is to be forwarded to the IMPACT GSE the SEP GSE will convert the stored command message into a standard command message based on the current time before forwarding it e Ifthe command message is to be forwarded to the IDPU simulator the SEP GSE will convert the stored message into the format expected by the IDPU simulator 24 bit command words The SEP GSE supports the forwarding of CCSDS command messages from the SEP sensor GSEs The sensor team assembles their commands into a command message that is sent to a dedicated SEP GSE command Socket The message format is described in section 4 above e When the SEP GSE receives the command messages and there are no time conflicts with other command messages it forwards it to the IMPACT GSE e Ifthe IMPACT GSE accepts the command message the SEP GSE will send an acceptance notice back to the originator If the IMPACT GSE does not accept the command message or the SEP GSE detects a time conflict the SEP GSE will return a rejection notice and discard the message 6 3 Commanding Security Command messages from the SEP sensor GSEs to the SEP GSE when sent over non secure networks will use the same SSH 2 protoco
30. ommand responses LET HET and SIT generate data in 272 byte CCSDS telemetry packets formatted as described in reference 16 SEP Central acquires packets from these sensors via the uni directional serial data link The protocols for data transfer are the same for LET HET and SIT These protocols are described in detail in references 8 11 STEREO IMPACT SEP Users Manual Page 13 STEREO CIT 007 J Each sensor shall set the checksum byte in every packet transmitted according to the protocol described in references 8 11 The only parts of any packet from LET HET SIT that are modified by SEP Central are e The UT time stamp in the header e The four least significant bits of the sub seconds field of the timestamp in the packet secondary header used as packet diagnostic flags by SEP Central e The packet checksum byte recalculated after the above two modifications are made Otherwise the packets are just passed on by SEP Central to the IMPACT IDPU Within a given minute interval e HET sends data packets during a 200 ms interval immediately following second ticks 0 3 57 e SIT sends data packets during a 200 ms interval immediately following second ticks 1 4 58 e LET sends data packets during a 200 ms interval immediately following second ticks 2 5 59 LET HET and SIT must send at least one packet during each window for diagnostic testing purposes More than one packet may be sent in the same window but packets s
31. on for beacon data is 144 bytes minute e HET 28 bytes min LET 46 bytes min SEPT 44 bytes min SIT 24 bytes min STATUS 2 bytes min During minute N 1 HET LET and SIT will each send a packet of beacon data collected during minute N to SEP Central HET LET and SIT will format Beacon data into 272 byte CCSDS packets using one of their allocated ApIDs to identify the packet see section 5 0 Each sensor will send one housekeeping packet once per minute HET LET and SIT will send their Beacon data packets to SEP Central during the second window available to them each minute Thus HET will always send its Beacon packet during tick 1 and SIT will always send its Beacon packet during tick 2 and LET will always send its Beacon packet during tick3 This allows for simplification of software in SEP Central Beacon data from HET LET and SIT should be positioned at the beginning of the beacon packets sent by those sensors to SEP Central STEREO IMPACT SEP Users Manual Page 15 STEREO CIT 007 J At the beginning of N 2 SEP Central will combine Beacon packets from HET LET and SIT with Beacon data gathered from SEPT all of the data having been collected during minute N on each sensor into a SEP Beacon message block The format of this message block is described in Section 8 of the IMPACT Serial Interface Doc It is not a CCSDS packet Referring to that document we find SEP Beacon message Message type 2 Message length 144byt
32. r ASCII CCSDS Consultative Committee for Space Data Systems CR Carriage Return character 0x0D CRLF Two characters CR and LF EEPROM Electronically Erasable Programmable Read Only Memory FPGA Field Programmable Gate Array GSE Ground Support Equipment HET High Energy Telescope ICD Interface Control Document IMPACT In situ Measurements of Particles and CME Transients LET Low Energy Telescope LF Line feed character Ox0A MISC Minimal Instruction Set Computer MOC Mission Operations Center POCC Payload Operations Control Center RAM Random Access Memory SCM Supplemented Command Message SEP Solar Energetic Particles SIT Suprathermal Ion Telescope SEPT Solar Electron Proton Telescope SEPT NS SEPT North South electronic unit SEPT E SEPT Ecliptic electronic unit SRAM Static Random Access Memory SRL Space Radiation Laboratory SSD Solid State Detector 2 SEP Overview The Solar Energetic Particles SEP sensor suite for IMPACT STEREO consists of the Solar Electron Proton Telescope SEPT the Suprathermal Ion Telescope SIT the Low Energy Telescope LET and the High Energy Telescope HET SEPT consists of two units on each spacecraft SEPT NS and SEPT E The SEP suite is designed to measure the intensities of energetic particles from solar flares and from Coronal Mass Ejection CME driven shocks over a wide range of energies intensities and particle types The LET HET and SIT sensors each require a dedicated microp
33. rates fewer science packets than the maximum number of science packets allocated to it SEP STEREO IMPACT SEP Users Manual Page 9 STEREO CIT 007 J Central may fill the unused slots with command response packets if any are available to be sent SEP Central transmits command response packets to the IMPACT IDPU per the protocols in reference 7 4 3 1 Format of SEP Command Responses In order that the SEP command response log be readable and easily deciphered SEP Central and HET LET SIT must adhere to some rules for command responses e The response to the simplest ASCII command CR shall be the following o HET CRLF followed by the prompt string HET gt o LET CRLF followed by the prompt string LET gt o SIT CRLF followed by the prompt string SIT gt o SEP Central CRLF followed by the prompt string SEP gt e In each case above the gt character in the prompt string is followed by a space character e The response to other ASCII commands shall be an ASCII response string followed by the response to the CR command as defined above The ASCII response string will generally echo the command but it may also contain other information 4 4 SEP Command List Here we define all SEP and LET commands and their parameters that are used in standard procedures Other commands are possible but would first need to be qualified on an EM unit HET and SIT commands are described elsewhere SEP
34. rocessor for onboard data processing and sensor control An additional microprocessor called SEP Central gathers data from all the SEP sensors gathers SEP housekeeping data controls the SEP SSD Bias power supply manages the SEP interface to the IMPACT IDPU and manages the interfaces to the sensors The SEPT NS and SEPT E units do not require dedicated microprocessors and are controlled directly by SEP Central The microprocessor used in LET and SEP Central is the P24 MISC Minimal Instruction Set Computer The P24 MISC developed at Caltech has a 24 bit CPU core with dual stack architecture intended to efficiently execute Forth like instructions The processor design is simple to allow implementation within field programmable gate arrays STEREO IMPACT SEP Users Manual Page 2 STEREO CIT 007 J FPGAs The microprocessor used in HET and SIT is called the CPU24 It is based closely on the design of the P24 MISC implemented with some modifications at GSFC to tailor the processor to their application Both the MISC and the CPU24 are implemented in the ACTEL 54SX72A FPGA There are two serial interfaces between the SEP sensors and the SEP Central MISC The first interface is bi directional for transferring boot code commands and command responses The second interface is uni directional for transferring data from the instruments to the SEP Central MISC The protocol for using these interfaces is defined in References 8 11 Details of memor
35. y I O operating system and other interfaces can be found in References 6 and 8 11 Processed data from the microprocessors associated with LET HET and SIT are gathered by the SEP Central MISC as described in references 8 9 and 11 and formatted for transmission to the IMPACT DPU as described in Reference 7 Data from SEPT NS and SEPT E are gathered directly by the SEP Central MISC as described in references 4 and 10 Onboard processing of SEPT data occurs in the SEP Central MISC as described in references and 4 before the data are formatted and transmitted to the IMPACT DPU Figure 2 1 shows a block diagram of the SEP Sensor Suite SEPT 1 Of 2 I F z PDFE FPGA Oo 2 TEL 1 OF 2 SRAM LOW VOLTAGE ah VOLTAGE REGULATION CONTROL INTERFACE TO IMPACT DPU pata gt SEP Central MISC SRAM amp EEPROM HOUSEKEEPING ADC SSD BIAS MISC Minimal Instruction Set Computer CPU24 GSFC version of MISC PDFE Particle Detector Front End PHA Pulse Height Analyser SSD Solid State Detector TOF Time of Flight 10 03 2002 Figure 2 1 SEP Sensor Suite Block Diagram STEREO IMPACT SEP Users Manual Page 2 STEREO CIT 007 J The SEP instruments are mounted at various locations on the spacecraft body consistent with their Field of View requirements as shown in figure 2 2 Ahead Spacecraft Behind Spacecraft E SEPENS sr