1. Decimal Point DigiCell devices provide measurements in fixed point form The position of decimal point can be selected by decimal point selection box Display Unit ko Display unit is only used for user interface of built in device display and for PC software The unit has no Single Interval computational function It can be selected to appropriate unit by the 3 10 7 3000 00 selection box Scale Type e and Max values Scale Type specifies how e will be handled Can be choosen from Single Interval Multi Interval and Multi Range e value is the increment or decrement of displayed value when load changes e value is based on the least significant decimal digit of measurement value i e the display value will increase or decrease by 0 02 if decimal point is selected as 1 00 and e selected as 2 The device uses only one e value for all range if Single Interval selected It displays the Maximum alert message over the Max value with a tolerance On Multi Interval or Multi Range selection two e and Max values will be available for selection as el e2 and Max1 Max2 Basically el is used for measurements below Max value and e2 is being used above Max value Max2 value corresponds to the alert value The difference between Multi Range and Multi Interval is the behavior of output when Max exceeded and fallen below The el is used below Max1 and e2 used above Max1 i
2. M S Digital Load Measurement System DLMS Virtual Panel V 1 0 USERS MANUAL This document intended to guide the user to install configure and use the DLMS Virtual Panel software DLMS Virtual Panel V 1 0 Digital Load Measurement System CONTENTS Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 Digital Load Measurement System 1 INTRODUCTION DLMS Virtual Panel is software that provides a visual user interface for monitoring and maintaining and calibrating a single DigiCell device at a time at basic user level 1 1 FEATURES Plug sensing Automatically senses a device connected to specified communications port with specified communication parameters Selects online and offline modes regarding the device connected Automatically detects device type and provides calibration and setup regarding the device connected Visual user interface Simulates the visual properties of the device connected for display and basic control buttons Provides easy device setup interface by Windows standard property window Easy device calibration method Logging Logs user events button hits run and exit events errors calibration and setup data to a text file Logs display values to text file in level triggered basis as data logging Data logging may have delay in order to ensure the data is setup after a load change Event groups to be logged can be selected Data to be logged can be selected from
3. may be unning 4 Setup will prompt for the directory for installation you may change it by Change Directory or you may leave it as default and continue to installation by clicking the icon button on the left of window Click this button to install OLAS VirtualPanel software to the specified destination directory Click here to begin setup r Director smiem m nnnm le ea Files OLMS YirtualPanel Change cel ol Exit Setup 5 Setup will install all necessary files and registry automatically and prompt when installation finished 6 Your computer may need to be rebooted after the installation the prompt will ask to reboot or do it later rebooting that time strongly recommended the software may not work properly if prompted and run without rebooting 7 The DLMS Virtual Panel icon will be added to start menu after the installation Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 Digital Load Measurement System 3 CONNECTIONS AND COMMUNICATIONS The physical connections must be established and the communication parameters must be specified properly to establish a link between the PC and the DigiCell device PC acts as DCE and Digicell devices functions as DTE in communications 3 1 CONNECTIONS DigiCell series communicate by ModBus protocol DigiCell series those have RS232 interface port can directly connected by a three wire communications cable to P
4. time value tare status Unit and point inclusion to values can be specified 1 2 MINIMUM SYSTEM REQIREMENTS Hardware Pentium Family CPU 233MHz or Higher 32MB RAM higher recommended 10MB harddisk space higher space recommended for data logging 800x600 high color or true color graphics adapter and compatible monitor Hardware COM ports RS232C RS485 converters for port CD ROM Drive required only for installation Software Windows 95 98 NT 2000 XP operating system Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 pi n M Digital Load Measurement System 2 SOFTWARE INSTALLATION 2 1 INSTALLATION PROCEDURE l Close all open applications running and insert the install CD into CD ROM Drive 2 The Setup utility will normally run automatically If it does not run your CD ROM may be configured not to run applications automatically then click My Computer on desktop click CD ROM icon next and run Setup Exe from CD 3 Setup will copy the files necessary for installation to the temporary folder automatically and will prompt a warning about closing the other applications click OK if there is no application currently running ga D HS ASSUME PES chile i EE OR eee fs ce ee aes ci pee oe x Welcome to the OLMS VirtualPanel installation program Setup cannot install syster tiles or update shared tiles if they are in use Before proceeding we recommend that you close any applications you
5. C DigiCell devices that have RS485 port need to be connected by an RS232 RS485 converter Digicell series with RS232 ports also communicates by the ModBus protocol ModBus protocol supports many devices can be connected to same communication line as a bus in case physical communication layer supports multi drop connections z 3 wire RS232 cable E P igiCe l ee RS232 interface does not support multi drop communications thus only one device can be connected to same line at a time even 1f ModBus communications used The RS232 cable can be obtained by the manufacturer Fiaure 1 Connection for RS232 port Diaicell devices RS485 is a multi drop communications layer but an RS232 RS485 converter must be devised to connect an RS485 bus to a communications port of a PC in order to match the electrical signals and direction of communication information flow A compatible RS485 RS232 converter can be obtained by the manufacturer PC See ce senate 3 P Attention RS485 RS232 conversion is a complicated process that includes the data direction control Many third party RS232 RS485 converters have a data direction control based on special functions of PC side communication ports or may have incompatible delays to run with DLMS software Third party converters may not function properly with DLMS software except those suggested by the manufacturer DLMS Virtual panel can communicate with any of the devices on a multi drop bus by changing the
6. DLMS VP 1000101 DLMS Virtual Panel V 1 0 M c5 Digital Load Measurement System 6 1 5 COMMUNICATIONS PARAMETERS Communications parameters are used to specify how the device communicates with the PC Please pay attention for following warnings before setting this parameters l Do not confuse PC communication parameters with Communications Parameters PC communication parameters that accessed by panel button directly specifies the PC side of operation 2 Specifying incorrect parameters may result access problems to device 3 Never change communication parameters if more than one device are operating on the same bus Options Protocol Specifies the major ModBus option RTU protocol is a binary protocol that devices detect the message Aye E termination by a specified time delay 3 9600 7 ASCII protocol is a text based data transfer and the termination 0 None 7 characters are standard Line Feed and Carriage Return ASCII characters In UE E brief RTU is faster than ASCII since 0 1 Bit 7 the amount of data flow requires less bytes to communicate ASCII method is supported by Digicell family since a PC is not essential as a master device PLC and third party equipment can also be used for this purpose Baudrate Parity Data Bits and Stop Bits Specifies the framing for communications Some combinations are not allowed by DigiCell devices Following combinations of framing are not supported RTU pr
7. arameters of DLMS Virtual Panel software matches factory default communication parameters of DigiCell devices The common adjustment will be the communication port selection if communication parameters of either the software or the device is not modified on purpose Please follow the steps below to establish a successful link between PC and the device l Connect the DigiCell device by appropriate cable to the communications port of PC 2 Power up the DigiCell i 3 Run DLMS Virtual Panel software 4 Click the following PC communications button to popup the PC communication settings window s 5 Select the communications port that the device is connected to the PC This option is COM1 by default You may need to change it to appropriate port if it is being used by another device 6 Click Apply and check the panel in background if the communication established successfully there may be an error message if any inappropriate port is selected Try another if you are not sure which port is being used 7 Click OK when finished A temporary offline condition will occur within a second and the connection will be saved automatically after clicking OK button Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 Digital Load Measurement System 4 CONTROL BUTTONS OVERVIEW Control buttons provide Zero Tare operations device setup calibration PC communication settings and logging preferences The general functions are depicted b
8. ation changed These steps may be repeated until a proper calibration accomplished Attention Steps in calibration cannot be undone It is necessary to complete all steps before closing the window in order not to lead an uncertain state of calibration Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 Digital Load Measurement System 5 2 CALIBRATION OF DIGICELL DLT SERIES DEVICES This feature 1s supported by the software but not documented since DigiCell DLT series are in development in time manual is being published Contact to the manufacturer for updated manuals if the DigiCell DLT device is being used Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 M Digital Load Measurement System 6 DEVICE SETUP Device setup enables the user to maintain major parameters of DigiCell connected The parameters ranges from the read only device serial number and ROM Version to Display unit output set points and communication parameters regarding the device type Parameters differ in digital input DigiCell devices such as DigiCell DLT and analog input DigiCell devices such as DigiCell DC xxx LCA X or LCA D Parameter functions will be explained in brief within this manual please refer to device manuals for detailed functional descriptions Some parameters can be updated only if the program key is ON on the device Please see the related device manuals for where the program key is located DLMS Virtual Panel iden
9. ation Gross Unload the scale and press The calibration process must be performed cet zero button The device 1 Unload the scale by following the steps described A AE E E E ad l The zero must be acquired from the is ZERO Click here amp Set Zero input Thus the scale must be unloaded first Enter a load value and load the scale with the load 7 a 2 Clicking the Click here amp Set Zero entered Device will assume Load the scale button will record the current input as the current load as entered zero and write back it to device memory This operation may take a few seconds that Te CM TRIES MF nter Load E EE 2 buttons will be disabled The green indicator will display zero after this operation when buttons clicked You completed may click close button to Me Click here amp Set Load exit this window when finished Ready for calibration Close 3 The scale must be loaded to a certain load to enable the system measure that load and calculate the gain factor 4 The load on the scale must be entered as the reference of current load that will be used in calculations 5 Clicking Click here amp Set Load button will result the calculations performed and written back to the device This may take a few seconds to done The green indicator will display the entered load after the write back 6 Clicking the Close button will update the calibration history of the device and will close the window 1f calibr
10. configuration of PC communication parameters of the software but not at a time As a convention of ModBus protocol all devices on the same bus must have the same communication parameters Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 Digital Load Measurement System 3 2 DEVICE COMMUNICATIONS DLMS Virtual Panel has continuous detection function that senses any device connected to the port specified with specified communication parameters Its user interface change to online mode automatically when compatible device detected at the port I DLMS Virtual Panel The software remains in offline mode and continuously keep trying to connect a compatible device if not detected or port or parameters does not match White crosses on buttons indicates these functions are not available when offline There will be no display information on simulated LCD of the device and will be in dark gray view simulating an ID P powered off device Once a device has been detected the simulated LCD display will indicate the load status of stability and zero DLM5 Virtual Panel upon current actual status All buttons will be enabled if the program key is enabled by the device The calibration button C may remain disabled with cross over it if the program is disabled by the device The device will not go into the online mode if the communication port and parameters selected differ those of the device The default communication p
11. elow please see the referenced section for details USER ZERO 0 Available only when online Provides the functionality to set the gross value to zero when clicked User zero can be operational in certain limits and conditions and may result to a warning message that this operation cannot be done if the conditions of measurement are not appropriate for this operation Please see device manuals for conditions for zero operation TARE TOGGLE T Available only when online Toggles tare between Gross and Net Tare mode Clicking this button will result the current captured value as the tare value and the net value is being displayed Clicking this button when a tare value is already captured will result the tare to be cleared and gross value displayed until a new tare value captured Tare functionality is limited to certain conditions and a warning message may be displayed if tare function cannot be done at that time Please see device manuals for conditions for tare operation CALIBRATION Available only when online and the program key is on Reads current calibration data from device and pops up the calibration window The calibration windows functionality depends on the device type Refer to the Calibration section of corresponding device type The program key is a hardware key on the device that is not accessible without sealing the device off This button will be disabled by a white cross on it when the program key is in off position P
12. lease refer the device manuals for the position of the program key SETUP set Available only when online Reads current setup from device and pops up the setup window Some information are protected by the program key and will not be written after the setup Setting up all available information will require the program key is in on state Please refer to Device Setup section for further information PC COMMUNICATION PARAMETERS Enables the user to change the parameters that the personal computer use in communications to a device The communication port baudrate framing properties and device ModBus number can be selected by the following window pops up after clicking this button Communication Options i Haudrate 9600 Protocol me Parity CE Apply HE Modbus Address Data Bits lest H Stop Bits Cancel The port must be selected as the port that is connected to the device The values Protocol Baudrate Parity Data Bits and Stop Bits must match the device connected HB Modbus Address is an ID of the device being communicated and must match the correct address which the device is being identified for either the device on the bus or a single device connected The address ranges 1 to 255 OK button saves selected parameters and closes the current window Apply does the some without closing the current window Cancel leaves settings as last Apply or OK clicked o LOGGING OPTIONS Enables the user to m
13. n Multi Interval Scale Type the e value that is being used returns to el if the measurement falls below Max The Multi Range option provides e value not to return to el state when measurement falls below Max unless measurement is actually zero with a tolerance 6 1 3 INPUT PARAMETERS Input parameters are devised for input measurements stability regarding to the input bridge ratio environmental conditions and load change characteristics The filtering mechanism and its parameters plays a major role for input measurement stability The input filter of Digicell devices are adaptive for fast load changes The combined behavior of Filter Size Filter Tolerance and Filter Escape Counts parameters are explained as adaptive filter behavior below The adaptive filter behavior The filtering mechanism is based on the average of measurements collected respectively and accumulated to FIFO method memory The size of the FIFO in number of measurements varies 1 to the Filter Size specified Each measurement from the input is compared to the current value that has been filtered and the last measurement from input enters to the FIFO filter directly if the difference between last measurement and the filter value is less than the Filter Tolerance value The measurement is disregarded if it exceeds the difference and counted as a possibly inappropriate value i e caused by mechanical vibration or electrical noise from the input The count is reset after fi
14. odify logging options Please refer to Logging section of this document for details 9 SYSTEM INFORMATION Opens an about dialog box and displays software information about DLMS Virtual Panel This window also includes rated values of DigiCell if connected at the time this button clicked Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 5 m Digital Load Measurement System 5 CALIBRATION Calibration process differs in digital input DigiCell devices such as DigiCell DLT and analog input DigiCell devices such as DigiCell DC xxx LCA X or LCA D Digicell series with digital input can communicate with multiple analog input DigiCell devices and the calibration process covers the corner calibration as well as overall calibration DigiCell series those use analog inputs calibrated only as overall calibration DLMS Virtual Panel identifies the device automatically and pops up the related calibration window if the calibration button clicked This button is enabled only if the program key is ON on the device Please see the related device manuals for where the program key is located on the device 5 1 CALIBRATION OF DIGICELL LCA X LCA D DC xxx SERIES DEVICES Once the calibration key pressed the software will read existing calibration data and the calibration history and will pop up the following window The green box indicates the current gross value measured and changes dynamically with the current load on the scale Guide for calibr
15. otocol with 7 Data Bits No Parity 7 Data Bits 1 Stop Bit Even or odd parity 8 Data Bits 2 Stop Bits Delay Initial delay before a ModBus package sent by the device This feature supported for slow response DCE devices or slow protocol converters Mostly specified as zero for PC environment Time Out Operates for different purposes regarding RTU or ASCII mode is being used It specifies the termination duration of the package when operating in RTU mode It specifies the cancellation time out if a premature package met while operating in ASCII mode ModBus Address The address of the device on the bus Must be specified properly even if only one device operates on bus of RS232 physical layer used for communication Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 Digital Load Measurement System 7 LOGS Logs are intended to be used not only for recording the measurements to a text file but also the events the user done by the software Logs can be enabled or disabled each item can be selected to be logged To maintain with logging controls the o Logging button must be clicked to open the following window i Enable Data Loging Treshold is kg t Ib as selected Delay j5 Seconds Capture Time Capture Status Capture Value Include Point Capture Tare Include Unit eee Program Files OLMS VirtualPanel Enable Event Loging Capture RunExit Capture Calib RAY Capture User Events Capture SetUp RW Capture J Bo
16. rnal analog to digital converter Attention These values must be selected lower when filter size is small Excessive Filter Escape Counts values may cause excessive delays in all conditions this value must be used with care Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 10 a Digital Load Measurement System 6 1 4 OUTPUT PARAMETERS Output parameters are devised to control of the device hardware outputs such as relays and analog output Relay outputs Determines setpoints and setpoint conditions for devices that support relay outputs Above or equal or Below options are selectable and can be based either on net value or gross 0 above or equal F One F value The units of setpoints n determined by the common 1 below 80 00 Olgos F measurement unit set by Display Unit from Display Tag BO Analog Output Determines the measurement output ratio of analog output to value 0 Net value F measured Analog output can be selected to be based on Net value or Gross value The From value corresponds The value 0 displayed and To value corresponds to Maximum value Max or Max2 value specified by Display tag The analog output decreases with increasing load if From value is lesser than To value The difference of From value an To value must be greater than 3mA s Values above 25mA and the difference below 10mA may cause loss of accuracy at output Document
17. rst in range measurement and the last measurement enters to the FIFO filter The FIFO completely cleared and restarts with last measurement acquired if the count of inappropriate values exceeds the Filter Escape Counts value The number of values in FIFO filter will grow from 1 measurement to the number of measurements specified by the Filter Size parameter Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 9 M Digital Load Measurement System A proper input stability is based on the followings that can be specified Input Range Specifies the input Wheatstone bridge ratio in mV V Selection of the proper range 1s important since the input of the device will go into overflow state and produce an error when the bridge ratio becomes higher than the selected value or the measurement will loose accuracy if selected excessively higher than the bridges maximum ratio Filter Size Filter size is the number of measurements that is buffered and used for calculations during filtering The greater the value the more stable measurements got and measurement speed reduces The lower the value the lower stability got and the device will respond faster to a change in its input Filter Tolerance and Filter Escape Counts Specifies the behavior of the system for adapting to fast load changes The value of Filter Tolerance is in Internal counts ranges from 0 to 1 048 576 that stands for the input measurement resolution of inte
18. tifies the device automatically and pops up the related setup window when the Setup SET button clicked 6 1 SETUP OF DIGICELL LCA X LCA D DC xxx SERIES DEVICES The setup window has 5 group of parameters Identity Parameters those identifies the device Display Parameters those effect how the device displays the measurements Input Parameters those control the measurements at device input Output Parameters those are related with hardware outputs of the device Communications Parameters those specify how the device communicates on the bus 6 1 1 IDENTITY PARAMETERS Serial Number Read only The serial number that has been specified during production ROM version Read only The version of device software Customer code Read only A code for some system specific behaviour 0 or 255 in standard systems Calibration Counts Read only The number identifying how many times device has been calibrated This number incremented each time when calibration made PC Calibration Software Read only The ID and name of the software that used for last calibration process Calibration Date Read only The date of calibration if known The date is updated each time after calibration by PC software The time may not be known if the device has been calibrated by its own user interface Document DLMS VP 1000101 DLMS Virtual Panel V 1 0 8 M Digital Load Measurement System 6 1 2 DISPLAY PARAMETERS
19. x Errors ee Program Filess OLMS VirtualPanels WARS Document DLMS VP 1000101 DLMS Virtual Panel V 1 0