Home

ELP-362D90 User`s Manual

image

Contents

1. Locating the Beacon When the beacon is immersed in water it will begin to radiate an acoustic signal which can be received and transformed into an audible signal by the RJE International Inc PRS 275 DPR 275 or DTI 300 Acoustic Pinger Receivers The PRS 275 Pinger Receiver can be used as a shipboard portable receiver to determine the general vicinity of the aircraft flight recorder After the area is known a diver can be deployed with the DPR 275 which will give the exact location of the aircraft flight recorder Other equivalent pinger receivers may also be used Figure 1 4 Locating the Aircraft After Water Activation User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 2 Specifications This section provides information on the operating and environmental specifications on the ELP 362D90 Underwater Locator Beacon General Specifications Specifications Operating Frequency Operating Depth Pulse Length Battery Kit Operating Life Battery Storage Life in Beacon Acoustic Output Acoustic Output After 90 Days Activation Beam Pattern Case Size Case Material Weight Storage Temperature Operating Temperature ELP 362D90 37 5 kHz 1 kHz 0 to 20 000 feet 6 096 meters 29ms P N B362 D90 01 Incl battery o ring lube amp inst 2 90 days 7 years 2 160 5 dB re 1 uPa 1 meter gt 157 0 1 uPa 1 meter Fresh or salt
2. 84 months from date of shipment from RJE International Inc Purchaser s receipt of any product delivered hereunder shall be an unqualified acceptance of and a waiver by Purchaser of the right of Purchaser to make a claim with respect to such product unless Purchaser gives RJE International Inc notice of any claim within 84 months after the receipt of such product This warranty is limited to repair or replacement of the said product at RJE International Inc plant in Irvine California providing the product was not abused or operated other than in accordance with the RJE International Inc instruction manuals RJE International Inc does not assume responsibility for any damage due to leakage or implosion RJE International Inc reserves the right to modify its warranty at any time in its sole discretion THIS LIMITED WARRANTY IS NOT TRANSFERABLE LIMITATION OF LIABILITY RJE INTERNATIONAL INC MAKES NO OTHER WARRANTY REGARDING ITS PRODUCTS OR THE PRODUCTS OF OTHERS EITHER EXPRESS OR IMPLIED AND ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEEDS THE FORGOING WARRANTIES IS HEREBY DISCLAIMED BY RJE INTERNATIONAL INC AND EXCLUDED FROM ANY AGREEMENT MADE BY ACCEPTANCE OF ANY ORDER RJE INTERNATIONAL INC DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES SET FORTH HEREIN INCLUDING ANY LIABILITY FOR PRODUCTS NOT BEING AVAILABLE FOR USE OR FOR LOST OR CORRUPTED DATA LOSS OF BUSINESS LOSS OF PROFITS LOSS OF USE O
3. ELP 362D90 LOCATOR BEACON 90 DAY BATTERY KIT B362 D90 01 MOUNTING BRACKET ASSEMBLY OPTION B362 0559 1 Figure 1 1 ELP 362D90 and Mounting Bracket User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 2 WATER SWITCH Figure 1 2 ELP 362D90 Installed in Mounting Bracket External Construction The beacon is contained in a water tight aluminum case capable of withstanding high impact shock and deep water immersion As shown in Figure 1 2 one of the end caps has a water activated built in switch that causes the beacon to begin transmitting when the switch comes in contact with water 1 30in 3 92in 3 10cm LE Figure 1 3 ELP 362D90 Dimensions User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 3 Internal Construction The major internal components of the beacon include a printed circuit board assembly a urethane encapsulated transducer assembly and a battery The battery is contained in its own separate user accessible compartment Theory of Operation The printed circuit board assembly generates all the necessary logic functions to produce a pulse with the desired characteristics The pulse is then transformed from a CMOS level square wave to a much larger 37 5 kHz sinusoidal pulse by a transformer The output of the transformer drives the urethane encapsulated transducer which propagates through the housing in the form of a tuned 37 5 kHz acoustic signal
4. 2D90 Underwater Locator Beacon 12 4 Beacon Maintenance This section covers the cleaning recommended testing interval disposal storage procedures and battery replacement for the ELP 362D90 Underwater Locator Beacon Beacon Cleaning The end cap with the water switch and the end cap with the exposed stainless steel contact should remain free and clear of dirt grease and dust The end caps should be cleaned with a mild detergent and dried thoroughly with a clean cloth This process should be repeated periodically depending on the local environment Periodic Beacon Test When the beacon is installed on a flight data or voice recorder the recommended maintenance interval is the same as that of the recorder or 24 months whichever is shortest Follow the Pre Deployment Tests referenced in Section 3 of this User s Manual Beacon Maintenance Precautions The following precautions should be exercised when handling or storing the beacon beacon battery should not be exposed to temperatures in excess of 71 C 160 F as the battery life can be reduced by storage ina high temperature environment Any situation that could possibly crush or penetrate the case of the beacon should be avoided User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 13 Battery Maintenance Replace the battery by the date stamped on the beacon label where the three letters represent the month and the four numbers re
5. 59002 1 Periodic Battery Storage Maintenance When battery is stored it is recommended maintaining 12 month maintenance interval to check battery voltage and proper storage conditions To check Battery Voltage use a high impedance minimum input impedance of 10 Megohms digital voltmeter If the voltmeter reading is 7 2 volts or less battery is not recommended for installation User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 15 Battery Storage Guidelines Cells should be stored in their original containers Store cells in a well ventilated cool dry area Cells should be placed in an isolated area away from combustible materials Never stack heavy objects on top of boxes containing lithium batteries to preclude crushing or puncturing the cell case Beacon Disposal If it is necessary to dispose of the beacon perform the Alternative Battery Check referenced in Section 3 of this User s Manual first If the battery voltage is 6 0 volts or more remove the battery and dispose of the battery and beacon in accordance with local regulations If the battery voltage is less than 6 0 volts DO NOT remove the battery access end cap and dispose of the beacon in accordance with local regulations ii Failure to observe these precautions could result the release of hazardous chemicals Beacon Storage When long term storage is required the beacon should be stored in a cool dry envi
6. E LIMITED WARRANTY OF RJE INTERNATIONAL INC GIVES PURCHASER SPECIFIC LEGAL RIGHTS AND PURCHASER MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO PURCHASER User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 19 7 Record of Revision Revision Date Section Paragraph Summary of change Authorized by A 07 18 14 Initial issue S Cole B 09 30 14 4 6 Battery Storage S Cole 01 19 15 4 4 Revised Torque and S Cole Parts list 4 F 1 Addition Battery S Cole Installation Kit Instructions 7 1 Addition of Record of S Cole Revision D 01 23 15 2 3 Additional Testing to S Cole Support Battery Install E 02 22 15 1 3 4 Figures Revised to show new S Cole Battery label Instructions F 06 05 15 2 1 and 2 Revised Beacon S Cole Specification 4 Figure 4 1 Revised Battery S Cole Instructions User s Manual February 2015
7. ELP 362D90 Underwater Locator Beacon User s Manual June 2015 P N 362 17001 D REV F RJE INTERNATIONAL INC RJE INTERNATIONAL INC 15375 Barranca Parkway Suite 1 112 Irvine California 92618 U S A www rjeint com Tel 1 949 727 9399 Fax 1 949 727 0070 e mail aviationsales rjeint com ELP 362D90 Underwater Locator Beacon i Preface This manual describes the installation and operation of the ELP 362D90 P N ELP 362D90 Underwater Locator Beacon water activated acoustic beacons designed for use on aircraft flight recorders This manual is divided into the following six sections Description Specifications Installation and Checkout Beacon Maintenance Return Procedures Warranty Proprietary Information The information description and illustrations in this manual are the property of RJE International Inc Materials may not be reproduced or disseminated without the prior written consent of RJE International Inc Changes RJE International Inc reserves the right to make changes to meet new specifications at any time without incurring any obligation to modify previously installed units This manual is provided for informational and reference purposes only and is subject to change without notice Notes and Warnings Where applicable special notes and warnings are presented as follows NOTE A reminder to check that certain criteria are met before proceeding further in a step or
8. F THE PRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF CAPITAL COST OF SUBSTITUTE OR REPLACEMENT PRODUCT FACILITIES OR SERVICES DOWN TIME CHARGES FOR PURCHASER S TIME AND EFFORT THE CLAIMS OF THIRD PARTIES INJURY TO PROPERTY OR ANY OTHER DIRECT INDIRECT SPECIAL RELIANCE INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESS OF THE NATURE OF THE CLAIM AND WHETHER OR NOT FORESEEABLE AND WHETHER OR NOT BASED ON BREACH OF WARRANTY CONTRACT OR TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY EVEN IF RJE INTERNATIONAL INC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR FOR ANY CLAIM BY ANY THIRD PARTY EXCEPT AS EXPRESSLY PROVIDED HEREIN THIS LIMITATION OF LIABILITY APPLIES BOTH TO PRODUCTS AND SERVICES AND SUPPORT PROVIDED PURCHASER UNDER THIS AGREEMENT NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN BY RJE INTERNATIONAL INC ITS AGENTS OR EMPLOYEES SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THE LIMITED WARRANTY PROVIDED ABOVE ANY AND ALL LIABILITY OF RJE INTERNATIONAL INC IS EXPRESSLY LIMITED TO THE PRICE PURCHASER HAS PAID FOR THE PRODUCTS PURCHASER S SOLE REMEDY AGAINST RJE INTERNATIONAL INC IN ANY DISPUTE UNDER THIS AGREEMENT SHALL BE TO SEEK RECOVERY OF THE AMOUNTS PURCHASER PAID PURSUANT TO THE LIMITED WARRANTY PROVIDED ABOVE UPON THE PAYMENT OF WHICH RJE INTERNATIONAL INC ITS AGENTS AND EMPLOYEES AND AFFILIATES WILL BE RELEASED FROM AND DISCHARGED OF ALL FURTHER OBLIGATIONS AND LIABILITY TO PURCHASER TH
9. Lithium Battery This article has been tested to TSO C142a Appendix 1 Table 2 and shown to contain all venting smoke fire and explosions caused by ignition of internal battery Any ignition within the article has been shown to be self extinguishing User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 6 3 Installation and Checkout This section encompasses the installation considerations and procedures for mounting the beacon using the mounting bracket kit and a pre deployment test that can be conducted using a RJE International Inc ATS 260 Acoustic Test set Installation Considerations To minimize the probability of physical damage or inadvertent activation the following precautions should be considered when mounting the beacon The beacon should normally be mounted in the aft mid section of the aircraft depending on the environmental conditions and should be mounted to a sturdy structure without weakening the structure itself The beacon should be mounted in an area guarded against heavy equipment tearing loose and striking the beacon and should be mounted in a way that provides convenient access during regular inspections and tests The beacon should be mounted in a clean dry area to decrease the probability of inadvertent activation Also if possible the beacon should be mounted with the water switch facing down to minimize the possibility of moisture gathering on the end cap The beacon should be m
10. TS 260 Acoustic Test Set To use the ATS 260 Acoustic Test Set to verify the battery condition and test the operations of the beacon use the following procedure 1 Attach the cable clip directly to the beacon housing as shown in Figure 3 4 It is not necessary to remove the beacon from the mount to conduct the test Although the cable clip can touch the beacon label it is important that at least part of the clip touch the bare aluminum surface of the beacon Apply the test set probe to the water activation switch as shown in Figure 3 4 Hold down the button labeled PUSH TO TEST on the test set handle Check the beacon battery condition by observing the green and red indicators on the test set If the green indicator is lit the battery is good If the red indicator is lit the battery should be replaced See Section 3 Alternate Battery Check Check the beacon operating condition by listening for an audible tone from the test set and or observing the amber indicator If there is an audible tone and the amber indicator is flashing the beacon is operating properly If there is no audible tone and the amber indicator is not flashing the beacon is not operating properly NOTE If the beacon does not operate properly return it RJE International Inc for service See Section 5 Return Procedures for instructions on how to return the beacon User s Manual February 2015 ELP 362D90 Underwater Locat
11. a on Cleaning 12 Periodic Beacon 12 Beacon Maintenance 12 Battery 13 Tooling Requirements nsii ache nes Mn ck 13 Reg irementS sra sa canta IS aaa RAS 14 Beacon 015 15 Battery Replacement Instructions 16 Return 17 A E EE E 18 Record of Revision een 19 User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 11 List of Figures Figure 1 1 ELP 362D90 and Mounting 1 Figure 1 2 ELP 362D90 Installed in Mounting 2 Figure 1 3 ELP 362D90 DiMensions vcccccssvssesoscecsessnssescavcsscnnscsessevessseccsgcesvecesavsdseesasasvseasseessesseneoss 2 Figure 1 4 Locating the Aircraft After Water 3 Figure 3 1 Mounting Bracket Hole Pattern ccccsssssssssssesscesscssscsssscsesscesccesc
12. cssscesesccsssessseessees 7 Figure 3 2 Securing the Mounting Bracket 8 Figure 3 3 Installing the Beacon into the Mounting Bracket 8 Figure 3 4 Connecting the ATS 260 Acoustic Test 1 10 User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 1 1 Description The ELP 362D90 Underwater Locator Beacon is a durable water activated underwater location aid The beacons transmit an acoustic signal at 37 5 kHz once every second after activation The acoustic output for the beacon will remain above 157 0 dB for 90 days The ELP 362D90 Underwater Locator Beacon with 90 day battery life meets the performance specifications of RTCA DO 160G as required by TSO C121b RJE International Inc also offers both a standard mounting bracket kit P N B362 05591 and a customer specific mounting bracket kit P N B362 08320 Either kit allows the beacon to be securely mounted Please contact RJE International Inc if the standard mounting bracket does not meet your needs The beacon and its standard mounting bracket are shown in Figure1 1 The beacon is also shown installed in its standard mounting bracket in Figure 1 2 and a dimensional outline of the beacon is shown in Figure 1 3 This section provides a general descriptive overview of the beacon its theory of operation and use ELP 360D90 USER S MANUAL
13. e 3 2 3 Slide the beacon into the bracket as shown in Figure 3 3 Rotate the beacon until the battery date is visible and secure it in place with the end plate and the three drilled socket head cap screws 4 Lockwire the drilled screws and clean the water activation switch refer to section 4 Beacon Cleaning 4X 0 19 DRILL THRU 5 75in 1 2 00in 1 9cm 5 1 1 50in 3 8cm 3cm Figure 3 1 Mounting Bracket Hole Pattern User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 8 2 00 0 22in 4 ik 5 1cm 0 6 10 5cm MOUNTING BRACKET ASSEMBLY 1 75in 4 4 WATER SWITCH FLAT WASHER CAP SCREW SELF LOCKING NUT 250in 6 4cm MINIMUM THREAD ENGAGEMENT Figure 3 2 Securing the Mounting Bracket RETAINING PLATE ELP 362D90 MOUNTING BRACKET MOUNTING HARDWARE 3PLCS Figure 3 3 Installing the Beacon into the Mounting Bracket User s Manual February 2015 ELP 362D90 Underwater Locator Beacon Pre Deployment Tests A pre deployment test on each beacon should be performed before and after mounting using the RJE International Inc ATS 260 Acoustic Test Set The test set can be used to check both the beacon s battery condition and operation Also an alternative method using a digital voltmeter can be used to check the beacon s battery condition A
14. emove the old battery from BATTERY MANUFACTURE the unit Dispose of the expended cell in accordance PRESSURE 100 99 with local regulations CASE A WARNING Never attempt to recharge the battery MONTH OF RJE INTERNATIONA Serious personal injury could result B ATIE RY STEPC Inspect the interior of the ELP 362D90 housing for evidence of leaking or corrosion and inspectall threads for any signs of damage BATTERY A WARNING Always keep both the housingand end cap threads free of dirt lint ete BATTERY ACCESS Install the new battery part number 362 99000 1 ACCESS Note that the battery label is marked with an arrow Insert the battery so the arrow points towards the top water turn on end of the unit Remove the O Ring from its groove end cap Clean O Ring groove of any dirt lint debris etc Liberally apply the O Ring lubricant to the new O Ring and place the lubricated O Ring in the end cap groove Note Use only lubricant provided with battery kit DO NOT SUBSTITUTE ANY OTHER LUBRICANT Re fasten the end cap to the housing Use the RJE International torque adapter to seat the end cap snugly Torque end cap to 25 to 30 inch pounds 2 7 to 3 4 newton meters Affix the 90 DAY BATTERY MMM YY LL label included with the kit to beacon below existing label Do not apply more than three labels on unit Contact RJE for instructions if more than three labels are present AN WARNING Do
15. notcross thread or apply excessive force to the end cap PLEASE CONTACT RJE INTERNATIONAL FOR ANY QUESTIONS OR RETURNS RJE International Inc Tel 949 727 9399 Fax 949 727 0070 e mail aviationsales rjeint com RETURNS Please have retum reason quantity and serial number of the ELP 362D90 ready DO NOT SHIP the ELP 362D90 without receiving a Return Material Authorization Figure 4 1 Standard Battery Kit Replacement Instructions User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 17 5 Return Procedures If you need to return an ELP 362D90 Underwater Locator Beacon for warranty service contact RJE International Inc for Return Material Authorization RMA number and shipping instructions RJE International Inc Tel 1 949 727 9399 Fax 1 949 727 0070 e mail aviationsales rjeint com You will need to provide the following information to receive a Return Material Authorization RMA Reason for return Number of beacons to be returned Serial number of each unit Shipping method if applicable NOTE Do not ship a beacon without a Return Material Authorization User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 18 6 Warranty LIMITED WARRANTY RJE International Inc warrants that the products sold hereunder shall be free from defects in materials and workmanship under normal use and service when correctly installed used and maintained for a period of
16. or Beacon 10 PUSH TO TEST ATS 260 ACOUSTIC TEST SET PROBE ELP 362D90 EMERGENCY LOCATING BEACON Figure 3 4 Connecting the ATS 260 Acoustic Test Set ATS 260 Acoustic Test Set Service The ATS 260 Acoustic Test Set is factory calibrated at the date of manufacture and requires recalibration every 3 years Return test set to RJE International for calibration See Section 5 Return Procedures for instructions on how to return the test set User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 11 Alternative Battery Check In addition to using the test set to check the beacon s battery condition a high impedance minimum input impedance of 10 Megohms digital voltmeter can be used to measure the battery voltage Use the following procedure to measure the battery voltage 1 Place the negative meter lead on the water activation switch 2 Place the positive meter lead on the bare aluminum surface of the beacon housing Do not place the meter lead on the label 3 Read the voltmeter If the voltmeter reading is 6 0 volts or more the beacon has sufficient operating power If the voltmeter reading is less that 6 0 volts DO NOT remove the battery access end cap See Section 5 Return Procedures for instructions on how to return the beacon 7 Failure to observe these precautions could result the release of hazardous chemicals User s Manual February 2015 ELP 36
17. ounted in an area that is protected from the outside elements This will assist in the long term prevention of corrosion The beacon should be mounted in an area where sound absorbent materials are not present Avoid affixing labels to the beacon or any other material that would affect the acoustic beam The shelf life of the battery will be decreased when exposure to higher than normal temperatures The maximum temperature where the beacon is mounted should not exceed 71 160 F Nonconformance to the mounting instructions or intended use may void the warranty User s Manual February 2015 ELP 362D90 Underwater Locator Beacon Installation Procedures Carefully unpack the beacon and inspect it for shipping damage If any damage is evident it should be reported to the freight carrier and to RJE International Inc The mounting bracket kit includes an aluminum mounting bracket an aluminum end plate three drilled for lockwire socket head cap screws and three lock washers NOTE Before installing the mounting bracket be sure that it will be possible to install and remove the beacon once the bracket is installed To mount the beacon perform the following steps 1 Refer to the mounting bracket hole pattern shown in Figure 3 1 and drill four 0 191 in 0 48 cm diameter holes 2 Secure the mounting bracket with four 10 32 stainless steel screws and associated hardware not supplied as shown in Figur
18. present the year Example MAR2022 is March of 2022 Other date codes prior to this manual revision include the following 1 Three letters represent the month and two numbers represent the year Example MAR 22 is March of 2022 2 Two numbers to the left of a represent the month and two numbers to the right of the represent the year Example 03 22 is March of 2022 Hazardous chemicals are used in the beacon battery Dispose of the battery in accordance with local regulations Awannine If Battery shrink sleeve is damaged removed exposing paper label or if battery is physically damaged DO NOT INSTALL BATTERY Use the battery replacement procedure provided with the lithium battery replacement kit P N 2 090 01 Battery replacement should be performed by authorized personnel only Tooling Requirements Torque Wrench Commercially Available 1 2 Socket Commercially Available Torque Adapter RJE International Inc B362 09111 ATS 260 Test Set RJE International Inc ATS 260 User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 14 Torque Requirements Bottom End Cap 25 to 30 inch pounds 2 7 to 3 4 newton meters Parts List ELP 362D90 Beacon ELP 362D90 1 Battery Replacement Kit B362 D90 01 1 Battery 362 99000 1 1 O Ring 362 69001 1 Lubricant Tube 999 00026 1 Instructions 362 19001 3 1 Label 90 DAY BATTERY MMM YY LL 362
19. ronment in its original shipping container User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 16 Battery Replacement Instructions amp RJE International 15375 Barranca Pkwy Ste 112 irvine CA 92618 USA ELP 362D90 UNDERWATER LOCATOR BEACON OPTIONAL BATTERY REPLACEMENT 8362 D90 01 INSTRUCTIONS Battery Manufacture Date Battery Expiration Date The battery replacement kit includes a lithium battery P N 362 99000 1 O0 RingP N 362 69001 O Ring lubricant tube P N 999 00026 replacement instructions P N 362 19001 3 and 90 DAY BATTERY MMM YY LL label P N 362 59002 Battery replacement must be conducted by the latest date stamped on the pinger label Remove the ELP 362D90 from the mounting bracket assembly and perform the Alternative Battery Check as described in the ELP 362D90 s User s Manual found in Section 3 under Pre Deployment Tests Ifthe measured voltage is less than 6 0 Volts DO NOT remove the battery access end cap Return the ELP 362D90to RJE Intemational for service A WARNING Failure to observe these precautions could result in the release of hazardous chemicals Ifthe measured voltage is 6 0 Volts or more proceed with the following battery replacement instructions STEP A Using the RJE International torque adapter B362 09111 remove end cap marked BATTERY ACCESS RENON AN WARNING Do notclamp the pinger in a vice YEAR OF STEP B Invert the housingto r
20. sequence Awannine A reminder that dangerous consequences could result if certain recommended procedures are not followed User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 11 Table of Contents 1 DESCrIPTION es 1 External 2 Internal COMStruction oo cc seeeceneeeeceeeseeecnesseeecsenseeecsesseseeenseseeeees 3 Theory of Operations 3 Locating the Beacon 3 SPECIICATIONS 53s eek SN ees 4 General 4 TSO Testing Qualification 5 Installation and amp 6 Installation Considerations 2 6 Installation Procedures 7 Pre Deployment Tests 9 5 260 Test Set a te aun eds aias 9 ATS 260 Acoustic Test Set Service sass 10 Alternative Battery 11 Beacon 12 Be
21. water immersion 80 sphere 1 30 in 3 30 cm diameter 3 92 in 10 cm long 7075 T6 aluminum 6 78 oz 192g Maximum 55 C 67 F to 71 C 160 F 2 C 28 F to 38 C 1002F User s Manual February 2015 ELP 362D90 Underwater Locator Beacon 5 TSO Testing Qualification Summary The beacon is designed to meet the performance specifications of RTCA DO 160G as required by TSO C121b A summary of the testing qualifications is presented in the table below ELP 362D90 Testing Qualification Summary RTCA DO Testing Conditions 160G Section Description of Test Conducted No Altitude Equipment tested to Category D2 50 000 ft Decompression 4 6 4 6 5 0 Overpressure Temperature Variation Equipment tested to category A Vibration Equipment tested to RTCA DO 160G Figure 8 4 Curve C Fixed Wing and Figure 8 2b Curve U2 Rotary Wing Sand and Dust Equipment tested to Category S Fungus Equipment tested to Category F 2 3 Salt Spray Equipment tested to Category S Magnetic Effect Equipment tested to Category Z Induced Signal Susceptibility Equipment tested to category ZC Performance environmental and Other Tests Crash Survivability Testing performed as required by AS8045a Limitations This article meets the minimum performance and quality control standards required by TSO C121b Installation of this article requires separate approval Additional Testing to Support Installation of

Download Pdf Manuals