Home

PXI-1000B User Manual - National Instruments

image

Contents

1. xi Conventions Used in This Manual xi Related Documentation xii Customer Communication xii Chapter 1 Getting Started Unpacking 1 1 What You Need to Get Started 1 1 Optional Equipment 1 2 Battery Pack and Cable for DC Capable PXI 1000B 1 2 Rack Mount Kit 1 2 Key Features 1 3 PXI 1000B Backplane Overview 1 3 Interoperability with CompactPCI 1 3 System Controller Slot 1 6 Star Trigger Slo
2. 2 6 Installing the Battery Pack DC Capable Power Supply Only 2 6 Charging the Battery Pack DC Capable Power Supply Only 2 6 Installing PXI Modules 2 7 Installing Filler Panels 2 9 Using the Chassis Initialization File 2 9 Contents PXI 1000B User Manual viii National Instruments Corporation Chapter 3 Maintenance Service Interval 3 1 Preparation 3 1 Cleaning 3 1 Interior Cleaning 3 2 Exterior Cleaning 3 2 Cleaning the Fan Filters 3 2 Resetting the AC Mai
3. 2 4 Table 2 3 Power Supply Status Indication DC Only 2 5 Table 3 1 Troubleshooting 3 4 Table A 1 AC Input Specifications for AC Only Power Supply A 1 Table A 2 DC Output Specifications for AC Only Power Supply A 2 Table A 3 AC Input Specifications for DC Capable Power Supply A 2 Table A 4 DC Input Specifications for DC Capable Power Supply A 3 Table A 5 DC Output Specifications for DC Capable Power Supply A 4 Table A 6 Cooling Specifications A 5 Table A 7 Safety Specifications A 5 Table A 8 Environmental Specifications A 6 Table A 9 Backplane Specifications A 7 Table A 10 Mechanical Specifications A 8 Table B 1 P1 J1 Connector Pinout for the System Controller Slot B 2 Table B 2 P2 J2 Connector Pinout for the System Controller Slot B 3 Table B 3 P1 J1 Connector Pinout for the Sta
4. The Glossary lists abbreviations acronyms metric prefixes mnemonics symbols and terms The Index contains an alphabetical list of key terms and topics used in this manual including the page where you can find each one Conventions Used in This Manual The following conventions are used in this manual This icon to the left of bold italicized text denotes a note which alerts you to important information This icon to the left of bold italicized text denotes a caution which advises you of precautions to take to avoid injury data loss or a system crash About This Manual PXI 1000B User Manual xii National Instruments Corporation This icon to the left of bold italicized text denotes a warning which advises you of precautions to take to avoid being electrically shocked bold italic Bold italic text denotes a note caution or warning italic Italic text denotes emphasis a cross reference or an introduction to a key concept This font also denotes text from which you supply the appropriate word or value as in Windows 3 x monospace Text in this font denotes text or characters that are to be literally entered from the keyboard sections of code programming examples and syntax examples This font is also used for the proper names of disk drives paths directories device names functions variables filenames and extensions Related Documentation The following documents contain information that
5. GND C BE 6 GND 3 GND PXI_LBR7 GND PXI_LBR8 PXI_LBR9 PXI_LBR10 GND 2 GND PXI_LBR11 PXI_LBR12 SYSEN PXI_LBL7 PXI_LBL8 GND 1 GND PXI_LBL9 GND PXI_LBL10 PXI_LBL11 PXI_LBL12 GND National Instruments Corporation C 1 PXI 1000B User Manual C Customer Communication National Instruments offers technical support through electronic fax and telephone systems The electronic services include our Web site an FTP site and a fax on demand system If you have a hardware or software problem please first try the electronic support systems If the information available on these systems does not answer your questions contact one of our technical support centers which are staffed by applications engineers for support by telephone and fax To comment on the documentation supplied with our products send e mail to techpubs natinst com Web Site The InstrumentationWeb address is http www natinst com From this Web site you can connect to our Web sites around the world http www natinst com niglobal and access technical support http www natinst com support FTP Site To access our FTP site log in to our Internet host ftp natinst com as anonymous and use your e mail address such as yourname anywhere com as your password The support files and documents are located in the support directories Fax on Demand Support Fax on Demand is a 24 hour information retrieval system containing a library of
6. Power Supply Fan Unit Replacement in under 5 minutes Table A 7 Safety Specifications Characteristic Description Safety Characteristics UL 3111 1 IEC 1010 1 CSA 22 2 No 1010 1 Installation Category II Pollution Degree 2 Safety Class 1 Appendix A Specifications PXI 1000B User Manual A 6 National Instruments Corporation Environmental Table A 8 Environmental Specifications Characteristic Description Operating Temperature 0 to 50 C Storage Temperature 20 to 70 C Operating Relative Humidity Maximum 80 for temperatures up to 31 C decreasing linearly to 50 at 40 C Functional Shock Operating MIL T 28800E CLASS 3 Half Sine Shock Pulse 11 ms duration 30 g peak Operating Location Indoor use Random Vibration Operational 5 to 500 Hz 0 31 gRMS Random Vibration Non Operational 10 to 500 Hz 2 46 gRMS EMC Emissions FCC Class A compliant and EN 55011 Group 1 Class A Compliant EMC Immunity Refer to DOC supplied with chassis for compliance to relevant directives Altitude 2 km 1 24 mi Random vibration profiles were developed in accordance with MIL T 28800E CLASS 3 and MIL STD 810E Method 514 Test levels exceed those recommended in MIL STD 810E for Category 1 Basic Transportation Figures 514 4 1 through 514 4 3 Appendix A Specifications National Instruments Corporation A 7 PXI 1000B User Manual Backplane Table A 9 Backplane Specificat
7. EXCEPT AS SPECIFIED HEREIN NATIONAL INSTRUMENTS MAKES NO WARRANTIES EXPRESS OR IMPLIED AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY THEREOF This limitation of the liability of National Instruments will apply regardless of the form of action whether in contract or tort including negligence Any action against National Instruments must be brought within one year after the cause of action accrues National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control The warranty provided herein does not cover damages defects malfunctions or service failures caused by owner s failure to follow the National Instruments installation operation or maintenance instructions owner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mechanical including p
8. GND V I O AD 11 AD 10 GND 19 GND 3 3V AD 15 AD 14 GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V SDONE SBO GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST GND GNT GND 4 GND BRSVP1A4 GND V I O INTP INTS GND 3 GND INTA INTB INTC 5V INTD GND 2 GND TCK 5V TMS TDO TDI GND 1 GND 5V 12V TRST 12V 5V GND Appendix B Pinouts National Instruments Corporation B 3 PXI 1000B User Manual Table B 2 P2 J2 Connector Pinout for the System Controller Slot Pin Z A B C D E F 22 GND PXI_RSVA22 PXI_RSVB22 PXI_RSVC22 PXI_RSVD22 PXI_RSVE22 GND 21 GND RSV GND RSV RSV RSV GND 20 GND RSV RSV RSV GND RSV GND 19 GND RSV GND RSV RSV RSV GND 18 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 GND PXI_TRIG6 GND 17 GND PXI_TRIG2 GND PRST REQ6 GNT6 GND 16 GND PXI_TRIG1 PXI_TRIG0 DEG GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND FAL REQ5 GNT5 GND 14 GND AD 35 AD 34 AD 33
9. M mega 106 Symbols Degrees Equal or greater than Equal or less than Percent A A Amperes AC Alternating current Ah Ampere hours ANSI American National Standards Institute AWG American Wire Gauge Glossary PXI 1000B User Manual G 2 National Instruments Corporation B backplane An assembly typically a printed circuit board with connectors and signal paths that bus the connector pins C C Celsius cfm Cubic feet per minute CFR Cooperative Fuel Research CSA Canadian Standards Association D daisy chain A method of propagating signals along a bus in which the devices are prioritized on the basis of their position on the bus DC Direct current E ECL Emitter coupled logic EIA Electronic Industries Association EMC Electromagnetic Compatibility F FCC Federal Communications Commission G g 1 grams 2 A measure of acceleration equal to 9 8 m s2 GPIB General Purpose Interface Bus IEEE 488 Glossary National Instruments Corporation G 3 PXI 1000B User Manual gRMS A measure of random vibration The root mean square of acceleration levels in a random vibration test profile H Hz Hertz cycles per second I IEC International Electrotechnical Commission an organization that sets international electrical and electronics standards IEEE Institute of Electrical and Electronics Engineers IMP Mainframe peak current in
10. 3 1 2 4 5 Chapter 2 Installation Configuration and Operation National Instruments Corporation 2 9 PXI 1000B User Manual Figure 2 3 Injector Ejector Handle Position during Module Insertion Installing Filler Panels To optimize module cooling performance install filler panels into unused or empty slots Secure with the captive mounting screws Using the Chassis Initialization File To assist system integrators the PXI specification requires manufacturers of PXI chassis and system modules to document the capabilities of their products The minimum documentation requirements are contained in ini files which consist of ASCII text The system integrator can read the ini file and configuration utilities and device drivers can also use this file The PXI 1000B chassis initialization file chassis ini is included on the diskette for your PXI 1000B National Instruments Corporation 3 1 PXI 1000B User Manual 3 Maintenance This chapter describes basic maintenance procedures you can perform on the PXI 1000B mainframe Service Interval Clean the mainframe fan filters at a maximum interval of six months Depending upon the amount of use and ambient dust levels in the operating environment the filters may require more frequent cleaning Clean dust from the mainframe exterior and interior as needed based on the operating environment Periodic cleaning increases reliability Preparation The informat
11. Inches L lb Pounds M m Meters MTBF Mean time between failure MTTR Mean time to repair N NEMA National Electrical Manufacturers Association P PXI PCI eXtensions for Instrumentation Glossary PXI 1000B User Manual G 4 National Instruments Corporation R RH Relative humidity RMS Root mean square A method used to measure electrical output in volts and watts S s Seconds ST Star Trigger Star Trigger slot This slot is located at slot 2 and has a dedicated trigger line between each peripheral slot Use this slot for a module with ST functionality that can provide individual triggers to all other peripherals System controller A module configured for installation in Slot 0 of a VXIbus mainframe This device is unique in the VXIbus system in that it performs the VMEbus system controller functions including clock sourcing and arbitration for data transfers across the backplane Installing such a device into any other slot can damage the device the VXIbus backplane or both U UL Underwriter s Laboratories V V Volts VAC Volts alternating current VPP Peak to peak voltage W W Watts National Instruments Corporation I 1 PXI 1000B User Manual Index A AC power cables table 1 1 B backplane 1 3 to 1 8 interoperability with CompactPCI 1 3 local bus 1 7 overview 1 3 peripheral slots 1 7 specifications A 7 Star Trigger ST slot 1 6 system ref
12. Pin Supply Acceptable Voltage Range 2 5 V 4 75 to 5 25 V 4 3 3 V 3 135 to 3 465 V 6 12 V 11 4 to 12 6 V 8 12 V 12 6 to 11 4 V 1 9 Logic Ground N A Table 2 2 DB 9 Connector Pinout DB 9 Pin Signal 1 Logic Ground 2 5 V 3 Inhibit Return DC capable supply only 4 3 3 V Chapter 2 Installation Configuration and Operation National Instruments Corporation 2 5 PXI 1000B User Manual You can use the Inhibit signal active low to turn off the power supply outputs To use this feature connect the Inhibit pin pin 5 to a Logic Ground pin pin 1 or 9 on the AC only input power supply or Inhibit Return pin 3 for the DC capable power supply Make sure the front standby switch is in the ON position As long as the connection is made the power supply inhibits its DC outputs DC output resumes when Inhibit is no longer connected Note that the power standby switch located on the front of the chassis uses this inhibiting feature For remote reset connect a momentary switch between pin 5 and pin 1 or pin 9 on the AC only input power supply or between pin 5 and pin 3 for the DC capable power supply Power Supply Status Indication DC Capable Power Supply Only If your PXI 1000B has a DC capable power supply refer to the following table for power supply indications provided by the Power Supply Status LED Refer to Figure 1 3 Rear View of the DC Capable PXI 1000B Mainframe for a d
13. Power switch is not switched on Set the power switch to the On position Remote inhibiting input on the rear panel of the mainframe is active Deactivate your system s remote inhibiting control Circuit breaker is tripped Reset the circuit breaker Refer to the Resetting the AC Mains Circuit Breaker section in this chapter If DC capable PXI 1000B is powered by an external DC source inline fuse on DC power cord may be blown Check fuse and replace if necessary If DC capable PXI 1000B is powered by optional battery pack the inline fuse to the battery pack may be blown Remove power supply see Installing the Battery Pack in Chapter 2 for procedure Check inline fuse to battery pack and replace if necessary If DC capable PXI 1000B is powered by an optional battery pack only the battery pack may be discharged Connect PXI 1000B to AC or DC power source to charge battery Notice The battery is charged whether the power switch is in the On or Standby position Power supply has failed Contact National Instruments National Instruments Corporation A 1 PXI 1000B User Manual A Specifications This appendix contains complete specifications for the PXI 1000B mainframe Electrical Table A 1 AC Input Specifications for AC Only Power Supply Characteristic Description Input Voltage Range 90 264 VAC Input Frequency Range 47 to 63 Hz Over Current Protection 10 A circuit breaker Maximum Stea
14. This device complies with the FCC rules only if used with shielded interface cables of suitable quality and construction National Instruments used such cables to test this device and provides them for sale to the user The use of inferior or nonshielded interface cables could void the user s authority to operate the equipment under the FCC rules If necessary consult National Instruments or an experienced radio television technician for additional suggestions The following booklet prepared by the FCC may also be helpful Interference to Home Electronic Entertainment Equipment Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 Canadian Department of Communications This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada For Your Safety Caution Before undertaking any troubleshooting maintenance or exploratory procedure read carefully the WARNING and CAUTION notices This equipment contains voltage hazardous to human life and safety and is capable of inflicting personal injury Mainframe Grounding The PXI 1000B mainframe requires a connection from the premise wire safety ground to the PXI 1000B chassis ground The earth safety ground must be connected during use of this equipment to minimize shock hazar
15. module installation 2 7 to 2 9 CompactPCI or PXI modules figure 2 8 injector ejector handle position figure 2 9 rack mounting 2 2 remote power monitoring and inhibiting interface 2 4 setting fan speed 2 2 site considerations 2 1 to 2 2 testing power up 2 3 unpacking the PXI 1000B 1 1 interoperability with CompactPCI 1 3 K key features 1 3 kit contents 1 1 L local bus routing figure 1 7 M maintenance of PXI 1000 cleaning exterior cleaning 3 2 fan filters 3 1 3 2 interior cleaning 3 2 preparation 3 1 resetting the AC mains circuit breaker 3 3 service interval 3 1 static discharge damage caution 3 1 maintenance of PXI 1000B 3 1 to 3 4 troubleshooting causes what to do table 3 4 O optional equipment 1 2 P P1 J1 connector peripheral slot table B 6 Star Trigger slot table B 4 system controller slot table B 2 P2 J2 connector peripheral slot table B 7 Star Trigger slot table B 5 system controller slot table B 3 peripheral slots overview 1 7 P1 J1 connector pinouts table B 6 P2 J2 connector pinouts table B 7 pinouts B 1 DB 9 connector table 2 4 P1 J1 connector peripheral slot table B 6 Star Trigger slot table B 4 system controller slot table B 2 Index National Instruments Corporation I 3 PXI 1000B User Manual P2 J2 connector peripheral slot table B 7 Star Trigger slot table B 5 system controller slot tabl
16. 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST GND GNT GND 4 GND BRSVP1A4 GND V I O INTP INTS GND 3 GND INTA INTB INTC 5V INTD GND 2 GND TCK 5V TMS TDO TDI GND 1 GND 5V 12V TRST 12V 5V GND Appendix B Pinouts National Instruments Corporation B 5 PXI 1000B User Manual Table B 4 P2 J2 Connector Pinout for the Star Trigger Slot Pin Z A B C D E F 22 GND PXI_RSVA22 PXI_RSVB22 PXI_RSVC22 PXI_RSVD22 PXI_RSVE22 GND 21 GND PXI_LBR0 GND PXI_LBR1 PXI_LBR2 PXI_LBR3 GND 20 GND PXI_LBR4 PXI_LBR5 PXI_STAR0 GND PXI_STAR1 GND 19 GND PXI_STAR2 GND PXI_STAR3 PXI_STAR4 PXI_STAR5 GND 18 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 GND PXI_TRIG6 GND 17 GND PXI_TRIG2 GND PRST PXI_CLK10_IN PXI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 DEG GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND FAL PXI_STAR6 PXI_LBR6 GND 14 GND AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND
17. 8 GND AD 56 AD 55 AD 54 GND AD 53 GND 7 GND AD 59 GND V I O AD 58 AD 57 GND 6 GND AD 63 AD 62 AD 61 GND AD 60 GND 5 GND C BE 5 GND V I O C BE 4 PAR64 GND 4 GND V I O PXI_BRSVB4 C BE 7 GND C BE 6 GND 3 GND PXI_LBR7 GND PXI_LBR8 PXI_LBR9 PXI_LBR10 GND 2 GND PXI_LBR11 PXI_LBR12 SYSEN PXI_STAR7 PXI_STAR8 GND 1 GND PXI_STAR9 GND PXI_STAR10 PXI_STAR11 PXI_STAR12 GND Appendix B Pinouts PXI 1000B User Manual B 6 National Instruments Corporation Table B 5 P1 J1 Connector Pinout for the Peripheral Slot Pin Z A B C D E F 25 GND 5V REQ64 ENUM 3 3V 5V GND 24 GND AD 1 5V V I O AD 0 ACK64 GND 23 GND 3 3V AD 4 AD 3 5V AD 2 GND 22 GND AD 7 GND 3 3V AD 6 AD 5 GND 21 GND 3 3V AD 9 AD 8 M66EN C BE 0 GND 20 GND AD 12 GND V I O AD 11 AD 10 GND 19 GND 3 3V AD 15 AD 14 GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V SDONE SBO GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V
18. CLK AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST GND GNT GND 4 GND BRSVP1A4 GND V I O INTP INTS GND 3 GND INTA INTB INTC 5V INTD GND 2 GND TCK 5V TMS TDO TDI GND 1 GND 5V 12V TRST 12V 5V GND Appendix B Pinouts National Instruments Corporation B 7 PXI 1000B User Manual Table B 6 P2 J2 Connector Pinout for the Peripheral Slot Pin Z A B C D E F 22 GND PXI_RSVA22 PXI_RSVB22 PXI_RSVC22 PXI_RSVD22 PXI_RSVE22 GND 21 GND PXI_LBR0 GND PXI_LBR1 PXI_LBR2 PXI_LBR3 GND 20 GND PXI_LBR4 PXI_LBR5 PXI_LBL0 GND PXI_LBL1 GND 19 GND PXI_LBL2 GND PXI_LBL3 PXI_LBL4 PXI_LBL5 GND 18 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 GND PXI_TRIG6 GND 17 GND PXI_TRIG2 GND PRST PXI_STAR PXI_CLK10 GND 16 GND PXI_TRIG1 PXI_TRIG0 DEG GND PXI_TRIG7 GND 15 GND PXI_BRSVA15 GND FAL PXI_LBL6 PXI_LBR6 GND 14 GND AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND 8 GND AD 56 AD 55 AD 54 GND AD 53 GND 7 GND AD 59 GND V I O AD 58 AD 57 GND 6 GND AD 63 AD 62 AD 61 GND AD 60 GND 5 GND C BE 5 GND V I O C BE 4 PAR64 GND 4 GND V I O PXI_BRSVB4 C BE 7
19. Only The optional battery pack is charged when either the AC power or the external DC power is connected regardless of the front STANDBY ON switch position The power supply has circuitry to prevent the battery pack from overcharging Optional Battery Pack On Yellow Optional Battery Pack Discharged On Red Table 2 3 Power Supply Status Indication DC Only Continued Power Source Power Switch Mode Status LED Chapter 2 Installation Configuration and Operation National Instruments Corporation 2 7 PXI 1000B User Manual Installing PXI Modules Caution Turn off the mainframe power before installing CompactPCI or PXI modules Install a module into a mainframe slot by first placing the module s card edges into the front module guides top and bottom as shown in Figure 2 2 Slide the module to the rear of the mainframe making sure that the injector ejector handle is pushed down as shown in Figure 2 3 Chapter 2 Installation Configuration and Operation PXI 1000B User Manual 2 8 National Instruments Corporation When you begin to feel resistance push up on the injector ejector handle to inject the card into the frame Secure the module s front panel to the mainframe using the module s front panel mounting screws Figure 2 2 Installing PXI or CompactPCI Modules 1 PXI 1000B Chassis 2 PXI 8156B System Controller 3 PXI Board 4 Injector Ejector Handle 5 Injector Ejector Rail
20. circuit breaker trips again complete the following steps 1 Turn the front panel power switch to the Standby position 2 Disconnect the mainframe from the AC mains power source 3 Remove all modules from the mainframe 4 Complete the test procedure described in the Connecting to Power Source and Testing Power up section in Chapter 2 Installation Configuration and Operation 5 If any voltages are outside the acceptable limits contact National Instruments 6 If all voltages are within the acceptable limits verify that your PXI 1000B can meet the power requirements of your CompactPCI or PXI modules Overloading the chassis can cause the breaker to trip Refer to Appendix A Specifications 7 The over current condition that caused the circuit breaker to trip may be due to a faulty CompactPCI or PXI module Refer to the documentation that was supplied with the modules for troubleshooting your modules Chapter 3 Maintenance PXI 1000B User Manual 3 4 National Instruments Corporation Troubleshooting the PXI 1000B Refer to Table 3 1 to troubleshoot the PXI 1000B mainframe The table lists possible causes for power failure and recommends ways to correct the problem Table 3 1 Troubleshooting Possible Cause What to Do PXI 1000B mainframe is not connected to power source Make sure that the PXI 1000B is connected to a live electrical outlet Try operating another piece of equipment from this outlet
21. documents in English on a wide range of technical information You can access Fax on Demand from a touch tone telephone at 512 418 1111 E Mail Support You can submit technical support questions to the applications engineering team through e mail at support natinst com Remember to include your name address and phone number so we can contact you with solutions and suggestions PXI 1000B User Manual C 2 National Instruments Corporation Telephone and Fax Support National Instruments has branch offices all over the world Use the following list to find the technical support number for your country If there is no National Instruments office in your country contact the source from which you purchased your software to obtain support Country Telephone Fax Australia 03 9879 5166 03 9879 6277 Austria 0662 45 79 90 0 0662 45 79 90 19 Belgium 02 757 00 20 02 757 03 11 Brazil 011 284 5011 011 288 8528 Canada Ontario 905 785 0085 905 785 0086 Canada Qu bec 514 694 8521 514 694 4399 Denmark 45 76 26 00 45 76 26 02 Finland 09 725 725 11 09 725 725 55 France 0 1 48 14 24 24 0 1 48 14 24 14 Germany 089 741 31 30 089 714 60 35 Hong Kong 2645 3186 2686 8505 India 91805275406 91805275410 Israel 03 6120092 03 6120095 Italy 02 413091 02 4139215 Japan 03 5472 2970 03 5472 2977 Korea 02 596 7456 02 596 7455 Mexico D F 5 280 7625 5 520 3282 Mexico Monterrey 8 357 7
22. that can provide individual triggers to all other peripherals However if you do not require advanced trigger functionality you can install any standard peripheral module into this slot 1 Module Cooling Air Outlets 2 Fan Speed Selector 3 Remote Power Status and Inhibit Connector 4 Power Supply Status LED 5 Chassis Ground Screw 6 Circuit Breaker 7 Universal AC Input 8 DC Power Input Connector 1 6 8 7 5 3 4 2 Chapter 1 Getting Started National Instruments Corporation 1 7 PXI 1000B User Manual Peripheral Slots There are seven peripheral slots including the Star Trigger controller slot Local Bus The PXI backplane s local bus is a daisy chained bus that connects each peripheral slot with its adjacent peripheral slots to the left and right as shown in Figure 1 4 For example a given peripheral slot s right local bus connects to the adjacent slot s left local bus and so on Each local bus is 13 lines wide and can pass analog signals between cards or provide a high speed side band communication path that does not affect the PXI bandwidth Local Bus signals may range from high speed TTL signals to analog signals as high as 42 V Initialization software keys adjacent boards to prohibit the use of incompatible boards This software uses the configuration information specific to each peripheral board to evaluate compatibility This method is a flexible way to define local bus functionality
23. that is not limited by hardware keying Figure 1 4 PXI Local Bus and Star Trigger Routing System Controller Slot 1 Star Trigger Peripheral Slot 2 Peripheral Slot 3 Peripheral Slot 4 Peripheral Slot 7 Peripheral Slot 8 Local Bus Local Bus Star Triggers PCI Arbitration and Clock Signals Local Bus Chapter 1 Getting Started PXI 1000B User Manual 1 8 National Instruments Corporation Trigger Bus The eight PXI trigger lines are bused to each slot You can use the trigger lines in a variety of ways For example you can use triggers to synchronize the operation of several different PXI peripheral modules In other applications one module can control carefully timed sequences of operations performed on other modules in the system Modules can pass triggers to one another allowing precisely timed responses to asynchronous external events the system is monitoring or controlling System Reference Clock The PXI 1000B supplies the PXI 10 MHz system clock signal PXI_CLK10 independently to each peripheral slot An independent buffer having a source impedance matched to the backplane and a skew of less than 1 ns between slots drives the clock signal to each peripheral slot You can use this common reference clock signal to synchronize multiple modules in a measurement or control system You can drive PXI_CLK10 from an external source through the PXI_CLK10_IN pin on the P2 connector of the Star Trig
24. you may find helpful as you read this manual Compact PCI Specification PICMG 2 0 R2 1 PXI Specification Revision 1 0 IEEE 1101 1 1991 IEEE Standard for Mechanical Core Specifications for Microcomputers Using IEC 603 2 Connectors IEEE 1101 10 and P1101 11 IEEE Standard for Additional Mechanical Specifications for Microcomputers Using IEEE 1101 1 Equipment Practice Customer Communication National Instruments wants to receive your comments on our products and manuals We are interested in the applications you develop with our products and we want to help if you have problems with them To make it easy for you to contact us this manual contains comment and configuration forms for you to complete These forms are in Appendix C Customer Communication at the end of this manual National Instruments Corporation 1 1 PXI 1000B User Manual 1 Getting Started This chapter describes the key features of the PXI 1000B mainframe lists the contents of your kit and lists optional equipment you can order from National Instruments Unpacking Carefully inspect the shipping container and the mainframe for damage Check for visible damage to the metal work Check to make sure all handles hardware and switches are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caused in shipment file a claim with the carrier Retain the packing materia
25. 695 8 365 8543 Netherlands 0348 433466 0348 430673 Norway 32 84 84 00 32 84 86 00 Singapore 2265886 2265887 Spain Madrid 91 640 0085 91 640 0533 Spain Barcelona 93 582 0251 93 582 4370 Sweden 08 587 895 00 08 730 43 70 Switzerland 056 200 51 51 056 200 51 55 Taiwan 02 2377 1200 02 2737 4644 United Kingdom 01635 523545 01635 523154 United States 512 795 8248 512 794 5678 Technical Support Form Photocopy this form and update it each time you make changes to your software or hardware and use the completed copy of this form as a reference for your current configuration Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently If you are using any National Instruments hardware or software products related to this problem include the configuration forms from their user manuals Include additional pages if necessary Name __________________________________________________________________________ Company _______________________________________________________________________ Address ________________________________________________________________________ _______________________________________________________________________________ Fax ___ ________________Phone ___ __________________________________________ Computer brand____________ Model ___________________Processor _____________
26. GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND 8 GND AD 56 AD 55 AD 54 GND AD 53 GND 7 GND AD 59 GND V I O AD 58 AD 57 GND 6 GND AD 63 AD 62 AD 61 GND AD 60 GND 5 GND C BE 5 GND V I O C BE 4 PAR64 GND 4 GND V I O PXI_BRSVB4 C BE 7 GND C BE 6 GND 3 GND CLK4 GND GNT3 REQ4 GNT4 GND 2 GND CLK2 CLK3 SYSEN GNT2 REQ3 GND 1 GND CLK1 GND REQ1 GNT1 REQ2 GND Appendix B Pinouts PXI 1000B User Manual B 4 National Instruments Corporation Table B 3 P1 J1 Connector Pinout for the Star Trigger Slot Pin Z A B C D E F 25 GND 5V REQ64 ENUM 3 3V 5V GND 24 GND AD 1 5V V I O AD 0 ACK64 GND 23 GND 3 3V AD 4 AD 3 5V AD 2 GND 22 GND AD 7 GND 3 3V AD 6 AD 5 GND 21 GND 3 3V AD 9 AD 8 M66EN C BE 0 GND 20 GND AD 12 GND V I O AD 11 AD 10 GND 19 GND 3 3V AD 15 AD 14 GND AD 13 GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V SDONE SBO GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND
27. PXI PXI 1000B User Manual PXI 1000B User Manual February 1999 Edition Part Number 321710C 01 Worldwide Technical Support and Product Information http www natinst com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin Texas 78759 3504 USA Tel 512 794 0100 Worldwide Offices Australia 03 9879 5166 Austria 0662 45 79 90 0 Belgium 02 757 00 20 Brazil 011 284 5011 Canada Ontario 905 785 0085 Canada Qu bec 514 694 8521 Denmark 45 76 26 00 Finland 09 725 725 11 France 0 1 48 14 24 24 Germany 089 741 31 30 Hong Kong 2645 3186 India 91805275406 Israel 03 6120092 Italy 02 413091 Japan 03 5472 2970 Korea 02 596 7456 Mexico D F 5 280 7625 Mexico Monterrey 8 357 7695 Netherlands 0348 433466 Norway 32 84 84 00 Singapore 2265886 Spain Madrid 91 640 0085 Spain Barcelona 93 582 0251 Sweden 08 587 895 00 Switzerland 056 200 51 51 Taiwan 02 2377 1200 United Kingdom 01635 523545 For further support information see the Technical Support Resources appendix of this manual Copyright 1997 1999 National Instruments Corporation All rights reserved Important Information Warranty The PXI 1000B is warranted against defects in materials and workmanship for a period of one year from the date of shipment as evidenced by receipts or other documentation National Instruments will at its option repair or replace equipment that proves to be defective during the warranty pe
28. ________ Operating system include version number ____________________________________________ Clock speed ______MHz RAM _____MB Display adapter __________________________ Mouse ___yes ___no Other adapters installed_______________________________________ Hard disk capacity _____MB Brand_________________________________________________ Instruments used _________________________________________________________________ _______________________________________________________________________________ National Instruments hardware product model _____________ Revision ____________________ Configuration ___________________________________________________________________ National Instruments software product ___________________ Version _____________________ Configuration ___________________________________________________________________ The problem is __________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ List any error messages ___________________________________________________________ _______________________________________________________________________________ ____________________________________
29. ___________________________________________ The following steps reproduce the problem ___________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ PXI 1000B Hardware Configuration Form Record the settings and revisions of your hardware and software on the line to the right of each item Complete a new copy of this form each time you revise your software or hardware configuration and use this form as a reference for your current configuration Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently National Instruments Products Complete Part Number ____________________________________________________________ Serial Number __________________________________________________________________ Line Voltage ____________________________________________________________________ Fan Speed ______________________________________________________________________ Safety Ground Connected _________________________________________________________ Rack Mount or Bench Top Configuration ____________________________________________ Using Remo
30. ________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ Thank you for your help Name _________________________________________________________________________ Title __________________________________________________________________________ Company _______________________________________________________________________ Address ________________________________________________________________________ _______________________________________________________________________________ E Mail Address __________________________________________________________________ Phone ___ __________________________ Fax ___ _______________________________ Mail to Technical Publications Fax to Technical Publications National Instruments Corporation National Instruments Corporation 11500 North Mopac Expressway 512 794 5678 Austin Texas 7875 3504 National Instruments Corporation G 1 PXI 1000B User Manual Glossary Prefix Meanings Value n nano 10 9 micro 10 6 m milli 10 3 c centi 10 2 k kilo 103
31. chanical A 8 safety A 5 Star Trigger ST slot description 1 6 P1 J1 connector pinouts table B 4 P2 J2 connector pinouts table B 5 status LED 2 5 system controller slot description 1 6 P1 J1 connector pinouts table B 2 Index PXI 1000B User Manual I 4 National Instruments Corporation P2 J2 connector pinouts table B 3 system reference clock 1 8 T testing power up 2 3 trigger bus 1 8 troubleshooting the PXI 1000B table 3 4 U unpacking the PXI 1000B 1 1 V voltages at power monitoring connector DB 9 table 2 4
32. connect the premise wire safety ground to the chassis grounding screw located on the rear panel Refer to Figure 1 2 Rear View of the AC Only PXI 1000B Mainframe or Figure 1 3 Rear View of the DC Capable PXI 1000B Mainframe for a diagram of the chassis grounding screw To connect the safety ground complete the following steps 1 Connect a 16 AWG 1 3 mm wire to the chassis grounding screw using a toothed grounding lug The wire must have green insulation with a yellow stripe or must be non insulated bare 2 Attach the opposite end of the wire to permanent earth ground using toothed washers or a toothed lug Connecting to Power Source and Testing Power up Caution Do not install modules prior to performing the first power on test If your PXI 1000B has an AC only input power supply attach input power through the rear AC inlet using the appropriate line cord supplied Refer to Figure 1 2 Rear View of the AC Only PXI 1000B Mainframe for a diagram of the IEC 320 inlet If your PXI 1000B has a DC capable power supply you can attach an AC line cord or a DC cord if a DC power source is available The power switch allows you to turn on the mainframe or place it in standby mode Push the power switch to the On position if not already on Observe that all fans become operational Caution When connecting digital voltmeter probes to the rear D sub connector be careful not to short the probe leads together Doing so could damage t
33. ds Refer to the Connecting Safety Ground section of Chapter 2 Installation Configuration and Operation for instructions on connecting safety ground Live Circuits Operating personnel and service personnel must not remove protective covers when operating or servicing the PXI 1000B Adjustments and service to internal components must be undertaken by qualified service technicians During service of this product the mains connector to the premise wiring must be disconnected Dangerous voltages may be present under certain conditions use extreme caution Explosive Atmosphere Do not operate the mainframe in conditions where flammable gases are present Under such conditions this equipment is unsafe and may ignite the gases or gas fumes Part Replacement Only service this equipment with parts that are exact replacements both electrically and mechanically Contact National Instruments for replacement part information Installation of parts with those that are not direct replacements may cause harm to personnel operating the mainframe Furthermore damage or fire may occur if replacement parts are unsuitable Modification Do not modify any part of the mainframe from its original condition Unsuitable modifications may result in safety hazards National Instruments Corporation vii PXI 1000B User Manual Contents About This Manual Organization of This Manual
34. dy State Operating Current 8 A Line Regulation 0 2 over operating line range Efficiency 70 typical Power Disconnect The standby power switch causes the power module to supply DC power to the CompactPCI PXI backplane The rear panel D sub connector facilitates remote inhibiting operation The standby switch must be in the On position prior to use of remote inhibit The power cord provides main power disconnect Appendix A Specifications PXI 1000B User Manual A 2 National Instruments Corporation Table A 2 DC Output Specifications for AC Only Power Supply Characteristic Description Maximum Usable Power 300 W DC Current Capacity IMP Voltage IMP Steady State Current 3 3 V 35 A 12 V 4 A 5 V 25 A 12 V 1 A Load Regulation Voltage Regulator 3 3 V lt 1 5 12 V lt 5 5 V lt 1 12 V lt 5 Maximum Ripple and Noise 1 ripple 1 noise 20 MHz bandwidth Over Current Protection All outputs protected from short circuit and overload automatic recovery Over Voltage Protection 3 3 V 5 V clamp at 20 to 30 above output voltage 12 V and 12 V clamp at 26 to 29 V referenced across and terminals Power Supply Fan Unit MTTR Replacement in under 5 minutes Table A 3 AC Input Specifications for DC Capable Power Supply Characteristic Description Input Voltage Range 85 265 VAC Input Frequency Range 45 to 65 Hz Over Current Prot
35. e B 3 power cables table 1 1 power monitoring connector See DB 9 connector power problems troubleshooting 3 4 power supply connecting to 2 3 DC power supply status indication table 2 5 input voltage priority DC only 2 6 remote power monitoring and inhibiting interface 2 4 voltages at power monitoring connector DB 9 table 2 4 power up testing 2 3 to 2 4 PXI_CLK10 1 8 PXI_CLK10_IN pin 1 8 PXI 1000B battery pack charging 2 6 description 1 2 installation 2 6 cooling air intake figure 2 2 fan speed setting 2 2 frontview figure 1 4 installation See installation and configuration key features 1 3 maintenance See maintenance of PXI 1000B optional equipment 1 2 rack mounting 2 2 rack mount kit 1 2 rearview of AC only figure 1 5 rearview of DC capable figure 1 6 safety ground connecting 2 3 PXI 1000B backplane 1 3 to 1 8 interoperability with CompactPCI 1 3 local bus 1 7 overview 1 3 peripheral slots 1 7 specifications A 7 Star Trigger ST slot 1 6 system reference clock 1 8 trigger bus 1 8 R rack mounting 2 2 rack mount kit 1 2 remote power monitoring and inhibiting interface 2 4 S safety ground connecting 2 3 safety specifications table A 5 safety warning and caution notices v service interval 3 1 setting fan speed 2 2 specifications A 1 to A 9 backplane A 7 cooling A 5 dimensions figure A 9 electrical A 1 to A 4 environmental A 6 me
36. ection 5 A circuit breaker Appendix A Specifications National Instruments Corporation A 3 PXI 1000B User Manual Operating Current RMS Steady State 3 0 A Line Regulation 0 2 over operating line range Efficiency 85 typical Power Disconnect The standby power switch causes the power module to supply DC power to the CompactPCI PXI backplane The rear panel D sub connector facilitates remote inhibiting operation The standby switch must be in the On position prior to use of remote inhibit The power cord provides main power disconnect Table A 4 DC Input Specifications for DC Capable Power Supply Characteristic Description Input Voltage Range 10 32 V DC to DC Isolation 500 VAC Over Current Protection Inline fuse must be installed into DC input cable Efficiency 82 typical Power Disconnect The front standby power switch causes the power module to supply DC power to the CompactPCI PXI backplane The rear panel D sub connector facilitates remote inhibiting operation The front standby switch must be in the On position prior to use of remote inhibit The power cord provides main power disconnect Table A 3 AC Input Specifications for DC Capable Power Supply Continued Characteristic Description Appendix A Specifications PXI 1000B User Manual A 4 National Instruments Corporation Table A 5 DC Output Specifications for DC Capable Power Supply Characteristic Descriptio
37. erence clock 1 8 trigger bus 1 8 battery pack charging 2 6 description 1 2 installation 2 6 C cables power table 1 1 chassis initialization file 2 9 CompactPCI installing modules figure 2 8 interoperability with PXI 1000B backplane 1 3 configuration See installation configuration and operation connector pinouts See pinouts cooling air cooling of PXI 1000 2 1 to 2 2 air intake figure 2 2 filler panel installation 2 9 setting fan speed 2 2 customer communication xii C 1 to C 7 documentation comment form C 7 e mail support C 1 Fax on Demand support C 1 FTP site C 1 hardware configuration form C 5 technical support form C 3 telephone and fax support C 2 D DB 9 connector pinout table 2 4 power supply voltages table 2 4 dimensions figure A 9 documentation conventions used in manual xi organization of manual xi related documentation xii E e mail support C 1 F fan setting speed 2 2 Fax on Demand support C 1 filler panel installation 2 9 FTP site C 1 G ground connecting 2 3 Index PXI 1000B User Manual I 2 National Instruments Corporation I IEC 320 inlet 1 5 2 3 installation configuration and operation 2 1 to 2 5 battery pack charging 2 6 installation 2 6 chassis initialization file 2 9 connecting safety ground 2 3 DC power supply status indication table 2 5 filler panel installation 2 9 input voltage priority DC only 2 6
38. ger Slot See Table B 1 P1 J1 Connector Pinout for the System Controller Slot in Appendix B Pinouts Sourcing an external clock on this pin automatically disables the backplane s 10 MHz source National Instruments Corporation 2 1 PXI 1000B User Manual 2 Installation Configuration and Operation This chapter describes how to prepare and operate your PXI 1000B mainframe Before connecting the mainframe to a power source read this chapter and the For Your Safety section located at the beginning of this manual Site Considerations The PXI 1000B is designed to operate on a bench or in an instrument rack Determine how you want to use your PXI 1000B and follow the appropriate installation instructions Apertures in the rear and along both sides of the mainframe facilitate power supply and module cooling Air enters through filters and fan inlets located in the lower rear of the mainframe and exits through the upper sections on both sides and through the rear as shown in Figure 2 1 Place your PXI 1000B on a bench top or in an instrument rack so that the fans air inlets and the air outlet apertures along both sides of the mainframe have adequate ventilation Keep other equipment a minimum of 3 0 in 76 2 mm away from the air inlets and outlets Chapter 2 Installation Configuration and Operation PXI 1000B User Manual 2 2 National Instruments Corporation Figure 2 1 PXI 1000B Mainframe Airflow Side View I
39. h a cloth moistened with clear water Do not use abrasive compounds on any part of the mainframe Cautions Avoid getting moisture inside the mainframe during exterior cleaning Use just enough moisture to dampen the cloth Do not wash the front or rear panel connectors or switches Cover these components while cleaning the mainframe Do not use chemical cleaning agents they may damage the mainframe Avoid chemicals that contain benzene toluene xylene acetone or similar solvents Cleaning the Fan Filters You can easily remove the mainframe cooling filters from the rear of the mainframe by removing the plastic housing attached to each fan Clean the fan filters by washing them in a mild soap solution and then vacuuming or blowing air through them Rinse the filters with water and allow them to dry before reinstalling them on the mainframe Chapter 3 Maintenance National Instruments Corporation 3 3 PXI 1000B User Manual Resetting the AC Mains Circuit Breaker If your PXI 1000B is connected to an AC source and encounters an over current condition the circuit breaker located on the rear panel will trip to prevent damage to the mainframe Complete the following steps to reset the circuit breaker 1 Turn the power switch to the Standby position 2 Disconnect the AC line cord 3 Depress the circuit breaker to reset it 4 Reconnect the AC line cord 5 Turn the power switch to the On position If the
40. he power supply You can use a digital voltmeter to ensure all voltage levels in your PXI 1000B are within the allowable limits Referring to Table 2 1 connect one lead of the voltmeter to a supply pin on the remote power monitoring Chapter 2 Installation Configuration and Operation PXI 1000B User Manual 2 4 National Instruments Corporation connector 9 pin D sub located on the rear panel Refer to Table 2 2 for a pinout diagram of the remote power monitoring connector Connect the reference lead of the voltmeter to one of the ground pins Compare each voltage reading to the values listed in Table 2 1 Note Use the rear panel D sub connector to check voltages only Do not use the connector to supply power to external devices If the voltages fall within the specified ranges the mainframe complies with the CompactPCI voltage limit specifications Notice that the rear panel D sub connector is to be used to check voltages only Do not use these voltages to supply power to external devices Note If the fans or power unit fail to function properly refer to the Troubleshooting the PXI 1000B section of Chapter 3 Maintenance Remote Power Monitoring and Inhibiting Interface The PXI 1000B mainframe supports remote power monitoring and inhibiting via a 9 pin D sub connector located on the rear panel Table 2 2 shows the pinout of the DB 9 connector Table 2 1 Power Supply Voltages at Power Monitoring Connector DB 9
41. hotocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation Trademarks PXI is a trademark of National Instruments Corporation Product and company names mentioned herein are trademarks or trade names of their respective companies WARNING REGARDING MEDICAL AND CLINICAL USE OF NATIONAL INSTRUMENTS PRODUCTS National Instruments products are not designed with components and testing for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human Applications of National Instruments products involving medical or clinical treatment can create a potential for death or bodily injury caused by product failure or by errors on the part of the user or application designer Because each end user system is customized and differs from National Instruments testing platforms and because a user or application designer may use National Instruments products in combination with other products in a manner not evaluated or contemplated by National Instruments the user or application designer is ultimately responsible for verifying and validating the suitability of National Instruments products whenever National Instruments products are incorporated in a system or application including witho
42. iagram of the Power Supply Status LED 5 Inhibit 6 12 V 7 Reserved 8 12 V 9 Logic Ground Table 2 3 Power Supply Status Indication DC Only Power Source Power Switch Mode Status LED AC or External DC Input Standby Green AC or External DC Input On Bright Green Table 2 2 DB 9 Connector Pinout Continued DB 9 Pin Signal 5 4 3 2 1 9 8 7 6 Chapter 2 Installation Configuration and Operation PXI 1000B User Manual 2 6 National Instruments Corporation Input Voltage Priority DC Capable Power Supply Only If more than one power source is connected at the same time the priority of the power sources is as follows 1 AC Module 2 DC Input 3 Internal Battery Pack Installing the Battery Pack DC Capable Power Supply Only If you purchased a DC capable PXI 1000B and an optional 1 7 Ah NiCd battery pack install it according to the following steps 1 Remove the power supply module by loosening the six captive screws on the rear of the PXI 1000B and pulling on the rear handles 2 Connect the two cables on the battery pack to the two cables in the opening in the rear of the power supply module 3 Insert the battery pack into the opening in the rear of the power supply module batteries facing inward and install the four screws provided 4 Reinstall the power supply module and tighten the six captive screws Charging the Battery Pack DC Capable Power Supply
43. install this kit on the front or rear of the chassis depending on which end of the chassis you wish to face toward the front of the instrument cabinet Note that the front and rear chassis mounting holes size M4 are symmetrical Figure A 1 PXI 1000B Dimensions 7 00 in 10 64 in 3 541 in 1 844 in 57 in 1 823 in 78 in 1 08 in 14 90 in National Instruments Corporation B 1 PXI 1000B User Manual B Pinouts This appendix describes the P1 and P2 connector pinouts for the PXI 1000B backplane Table B 1 shows the P1 J1 connector pinout for the System Controller slot Table B 2 shows the P2 J2 connector pinout for the System Controller slot Table B 3 shows the P1 J1 connector pinout for the Star Trigger slot Table B 4 shows the P2 J2 connector pinout for the Star Trigger slot Table B 5 shows the P1 J1 connector pinout for the peripheral slots Table B 6 shows the P2 J2 connector pinout for the peripheral slots Note PXI signals are shown in boldface Appendix B Pinouts PXI 1000B User Manual B 2 National Instruments Corporation Table B 1 P1 J1 Connector Pinout for the System Controller Slot Pin Z A B C D E F 25 GND 5V REQ64 ENUM 3 3V 5V GND 24 GND AD 1 5V V I O AD 0 ACK64 GND 23 GND 3 3V AD 4 AD 3 5V AD 2 GND 22 GND AD 7 GND 3 3V AD 6 AD 5 GND 21 GND 3 3V AD 9 AD 8 M66EN C BE 0 GND 20 GND AD 12
44. ion in this section is designed for use by qualified service personnel Read the For Your Safety section at the beginning of this manual before attempting any procedures in this chapter Caution Many components within the mainframe are susceptible to static discharge damage Service the mainframe only in a static free environment Observe standard handling precautions for static sensitive devices while servicing the mainframe Always wear a grounded wrist strap or equivalent while servicing the mainframe Cleaning Cleaning procedures consist of exterior and interior cleaning of the mainframe and cleaning the fan filters Refer to your module user documentation for information on cleaning the individual CompactPCI or PXI modules Caution Always power off the mainframe and disconnect the power cord before cleaning or servicing the mainframe Chapter 3 Maintenance PXI 1000B User Manual 3 2 National Instruments Corporation Interior Cleaning Use a dry low velocity stream of air to clean the interior of the mainframe Use a soft bristle brush for cleaning around components If you must use a liquid for minor interior cleaning use a 75 isopropyl alcohol solution and rinse with deionized water Exterior Cleaning Clean the exterior surfaces of the mainframe with a dry lint free cloth or a soft bristle brush If any dirt remains wipe with a cloth moistened in a mild soap solution Remove any soap residue by wiping wit
45. ions Characteristic Description Size 3U sized one system slot with three system expansion slots and seven peripheral slots Compliant with IEEE 1101 10 mechanical packaging PXI Specification Revision 1 0 compliant Accepts both PXI and CompactPCI PICMG 2 0 R2 1 3U modules Backplane Bare Board Material UL 94 V 0 recognized File No E 116551 Backplane Connectors Conform to IEC 917 and IEC 1076 4 101 and are UL 94 V 0 rated Appendix A Specifications PXI 1000B User Manual A 8 National Instruments Corporation Mechanical Table A 10 Mechanical Specifications Characteristic Description Overall Dimensions Standard Mainframe Height Width Depth 17 78 cm 7 00 in 27 02 cm 10 64 in 37 85 cm 14 90 in Notes 1 80 cm 71 in added to height when feet are installed When tilted with front feet extended on table top height is increased approximately 5 29 cm 2 083 in in front and 1 48 cm 583 in in rear Weight 8 6 kg 19 lb Maximum Module Weight 1 8 kg 4 lb Materials Sheet Aluminum 5052 H32 and Cold Rolled Steel Finish Unpainted Aluminum Cold Rolled Steel Paint Conductive Clear Iridite Clear Chromate Zinc Plating Polyurethane Enamel Appendix A Specifications National Instruments Corporation A 9 PXI 1000B User Manual Figure A 1 shows the PXI 1000B dimensions The holes shown are for the installation of the optional rack mount kit You can
46. l for possible inspection and or reshipment What You Need to Get Started The PXI 1000B kit contains the following items K PXI 1000B mainframe K Filler panels K AC power cable see Table 1 1 for AC power cables K PXI 1000B User Manual K Floppy disk with Chassis Initialization file chassis ini Table 1 1 AC Power Cables Power Cable Reference Standards Standard 120 V USA ANSI C73 11 NEMA 5 15 P IEC83 Switzerland 220 V SEV Australia 240 V AS C112 Chapter 1 Getting Started PXI 1000B User Manual 1 2 National Instruments Corporation If you are missing any of the above items or if you have the incorrect power cord contact National Instruments Optional Equipment Contact National Instruments to order the following options for your PXI 1000B mainframe Battery Pack and Cable for DC Capable PXI 1000B A DC input capable power supply is optionally installed in your PXI 1000B mainframe at the factory The DC capable supply can be powered with AC input or 10 to 32 VDC input and has 150 W of output If you have purchased a PXI 1000B with the DC capable power supply you can install an optional 1 7 Ah NiCd battery pack The mainframe can draw power from this battery pack and operate when no AC or DC input are present or if the DC input drops below 10 V The battery can power the PXI 1000B for up to 12 minutes under full load A DC input cable is available for the PXI 1000B with the DC capable power s
47. le chassis Figure 1 1 Front View of the PXI 1000B Mainframe 1 Remote On Off Standby Switch 2 Backplane Connectors Located in Slots 1 8 3 Optional Mounting Brackets 4 Removable Feet 5 Peripheral Slots 6 Star Trigger Slot 7 System Controller Slot 8 Controller Expansion Slots 5 1 2 3 3 7 6 4 8 4 P2 P1 Chapter 1 Getting Started National Instruments Corporation 1 5 PXI 1000B User Manual Figure 1 2 Rear View of the AC Only PXI 1000B Mainframe 1 Module Cooling Air Outlets 2 Fan Speed Selector 3 Remote Power Status and Inhibit Connector 4 Chassis Ground Screw 5 Circuit Breaker 6 Universal AC Input 1 5 6 4 3 2 Chapter 1 Getting Started PXI 1000B User Manual 1 6 National Instruments Corporation Figure 1 3 Rear View of the DC Capable PXI 1000B Mainframe System Controller Slot The System Controller slot is located in Slot 1 of the chassis as defined by the PXI specification It has three controller expansion slots which are used for system controller modules that are wider than one slot As defined in the PXI specification these slots allow the controller to expand to the left to prevent the controller from using up peripheral slots Star Trigger Slot The Star Trigger ST slot is located at Slot 2 This slot has a dedicated trigger line between each peripheral slot see Figure 1 4 This slot is intended for modules with ST functionality
48. n Maximum Usable Power 160 W DC Current Capacity IMP Voltage IMP Steady State Current 3 3 V 10 A 12 V 4 A 5 V 20 A 3 3 V power 12 V 0 4 A Load Regulation Voltage Regulator 3 3 V lt 2 12 V lt 2 5 V lt 2 12 V lt 5 Maximum Ripple and Noise 1 ripple 1 noise 20 MHz bandwidth Over Current Protection All outputs have over current protection Restart by ON STANDBY switch Over Voltage Protection 20 to 35 above output voltage causes supply shutdown Restart by ON STANDBY switch Power Supply Fan Unit MTTR Replacement in under 5 minutes Appendix A Specifications National Instruments Corporation A 5 PXI 1000B User Manual Cooling Safety Table A 6 Cooling Specifications Characteristic Description Per Slot Cooling Capacity Slot cooling capacity in worst case slot is 20 W with fan speed set to HI Module Cooling System Forced air circulation positive pressurization via two 60 cfm fans with HI LO speed selector Slot Airflow Direction P1 to P2 bottom of module to top of module Module Cooling Intake Bottom rear of mainframe Module Cooling Exhaust Along both sides of mainframe Power Supply Cooling System Forced air circulation via integrated fan Power Supply Cooling Intake Rear of mainframe Power Supply Cooling Exhaust Along both sides of mainframe rear and upper rear panel Module Cooling Fan MTBF 40 000 hr
49. ns Circuit Breaker 3 3 Troubleshooting the PXI 1000B 3 4 Appendix A Specifications Appendix B Pinouts Appendix C Customer Communication Glossary Index Figures Figure 1 1 Front View of the PXI 1000B Mainframe 1 4 Figure 1 2 Rear View of the AC Only PXI 1000B Mainframe 1 5 Figure 1 3 Rear View of the DC Capable PXI 1000B Mainframe 1 6 Figure 1 4 PXI Local Bus and Star Trigger Routing 1 7 Figure 2 1 PXI 1000B Mainframe Airflow Side View 2 2 Figure 2 2 Installing PXI or CompactPCI Modules 2 8 Figure 2 3 Injector Ejector Handle Position during Module Insertion 2 9 Figure A 1 PXI 1000B Dimensions A 9 Contents National Instruments Corporation ix PXI 1000B User Manual Tables Table 1 1 AC Power Cables 1 1 Table 2 1 Power Supply Voltages at Power Monitoring Connector DB 9 2 4 Table 2 2 DB 9 Connector Pinout
50. nstall your mainframe so that you can easily access the rear panel This simplifies the replacement of the air filters or power supply fan assembly if necessary Rack Mounting Rack mount applications require the optional rack mount kit available from National Instruments Refer to the instructions supplied with the rack mount kit to install your PXI 1000B in an instrument rack Note You may wish to remove the feet from your PXI 1000B when rack mounting To do so remove the screws holding the feet in place Setting Fan Speed The fan speed selector switch is located on the rear panel of the PXI 1000B Refer to Figure 1 2 Rear View of the AC Only PXI 1000B Mainframe or Figure 1 3 Rear View of the DC Capable PXI 1000B Mainframe for a diagram of the fan speed selector Select HI for maximum cooling effectiveness recommended or LO for quiet operation 1 Module Cooling Air Outlets 2 Module Cooling Air Intake 1 2 Chapter 2 Installation Configuration and Operation National Instruments Corporation 2 3 PXI 1000B User Manual Connecting Safety Ground Warning The PXI 1000B chassis is designed with a three position NEMA 15 5 style plug that connects the ground line to the chassis ground To minimize shock hazard make sure your electrical power outlet has an appropriate earth safety ground that is connected whenever you power up the chassis If your power outlet does not have an appropriate ground connection you must
51. r Trigger Slot B 4 Table B 4 P2 J2 Connector Pinout for the Star Trigger Slot B 5 Table B 5 P1 J1 Connector Pinout for the Peripheral Slot B 6 Table B 6 P2 J2 Connector Pinout for the Peripheral Slot B 7 National Instruments Corporation xi PXI 1000B User Manual About This Manual The PXI 1000B User Manual describes the features of the PXI 1000B mainframe and contains information about configuring the mainframe installing the modules and operating and using the PXI 1000B Organization of This Manual This manual is organized as follows Chapter 1 Getting Started describes the key features of the PXI 1000B mainframe lists the contents of your kit and lists optional equipment you can order from National Instruments Chapter 2 Installation Configuration and Operation describes how to prepare and operate your PXI 1000B mainframe Chapter 3 Maintenance describes basic maintenance procedures you can perform on the PXI 1000B mainframe Appendix A Specifications contains complete specifications for the PXI 1000B mainframe Appendix B Pinouts describes the P1 and P2 connector pinouts for the PXI 1000B backplane Appendix C Customer Communication contains forms you can use to request help from National Instruments or to comment on our products and manuals
52. r power supply Remote power status and inhibit via a rear panel connector On Off Standby switch located on the front panel for easy access Selectable fan speed for maximum cooling or quiet operation Carrying handle for portability Tilt feet for bench top applications PXI 1000B Backplane Overview Interoperability with CompactPCI The PXI 1000B backplane is interoperable with PXI compatible products and standard CompactPCI products This is an important feature as many PXI compatible systems may not require components that do not implement PXI specific features For example you may want to use a standard CompactPCI network interface card in a PXI chassis The signals on the P1 connector of the backplane meet the requirements of the CompactPCI specification for both the peripheral and system modules Chapter 1 Getting Started PXI 1000B User Manual 1 4 National Instruments Corporation The PXI specific signals are located on P2 and are only found on the signals that are reserved or not used in the CompactPCI 64 bit specification Therefore all modules that meet the requirements of the CompactPCI 64 bit specification will function in the PXI 1000B Figures 1 1 1 2 and 1 3 show some of the key features and components of the PXI 1000B mainframe Figure 1 1 shows the front view of the PXI 1000B Figure 1 2 shows the rear view of the AC only chassis and Figure 1 3 shows the rear view of the DC capab
53. riod This warranty includes parts and labor The media on which you receive National Instruments software are warranted not to fail to execute programming instructions due to defects in materials and workmanship for a period of 90 days from date of shipment as evidenced by receipts or other documentation National Instruments will at its option repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period National Instruments does not warrant that the operation of the software shall be uninterrupted or error free A Return Material Authorization RMA number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty National Instruments believes that the information in this document is accurate The document has been carefully reviewed for technical accuracy In the event that technical or typographical errors exist National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition The reader should consult National Instruments if errors are suspected In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it
54. t 1 6 Peripheral Slots 1 7 Local Bus 1 7 Trigger Bus 1 8 System Reference Clock 1 8 Chapter 2 Installation Configuration and Operation Site Considerations 2 1 Rack Mounting 2 2 Setting Fan Speed 2 2 Connecting Safety Ground 2 3 Connecting to Power Source and Testing Power up 2 3 Remote Power Monitoring and Inhibiting Interface 2 4 Power Supply Status Indication DC Capable Power Supply Only 2 5 Input Voltage Priority DC Capable Power Supply Only
55. te Power Monitoring ____________________________________________________ Filler Panels Installed in Empty Slots ________________________________________________ Other Products List and describe all devices installed in your mainframe Slot Manufacturer Description and Function 1 2 3 4 5 6 7 8 Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products This information helps us provide quality products to meet your needs Title PXI 1000B User Manual Edition Date February 1999 Part Number 321710C 01 Please comment on the completeness clarity and organization of the manual _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ If you find errors in the manual please record the page numbers and describe the errors _______________________________________________________________________________ _______________________________
56. upply This cable contains an inline fuse and has banana jacks for easy connection to various DC sources Rack Mount Kit An optional rack mount kit is available from National Instruments You can use this kit to install the PXI 1000B mainframe into a standard 19 in 482 mm instrument cabinet Universal Euro 240 V CEE 7 II IV VII IEC83 North America 240 V ANSI C73 20 NEMA 5 15 P IEC83 United Kingdom 240 V BS 1363 IEC83 Table 1 1 AC Power Cables Continued Power Cable Reference Standards Chapter 1 Getting Started National Instruments Corporation 1 3 PXI 1000B User Manual Key Features The PXI 1000B combines a high performance 8 slot PXI backplane with a high output power supply and a structural design that has been optimized for maximum usability in a wide range of applications The mainframe s modular design ensures the highest level of maintainability resulting in a very low mean time to repair MTTR The PXI 1000B fully complies with the PXI Specification Revision 1 0 offering advanced timing and synchronization features The key features of the PXI 1000B include PXI and CompactPCI PICMG 2 0 R 2 1 module compatibility Compact 3U sized 8 slot chassis 300 W of usable power 150 W for DC capable supply Universal AC input auto voltage and auto frequency ranging Over current protection via push reset circuit breaker no loose fuses to replace Removable modula
57. ut limitation the appropriate design process and safety level of such system or application Compliance FCC DOC Radio Frequency Interference Class A Compliance This equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the instructions in this manual may cause interference to radio and television reception Classification requirements are the same for the Federal Communications Commission FCC and the Canadian Department of Communications DOC This equipment has been tested and found to comply with the following two regulatory agencies Federal Communications Commission This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notices to User Changes or modifications not expressly approved by National Instruments could void the user s authority to operate the equipment under the FCC Rules

Download Pdf Manuals

image

Related Search

Related Contents

Philips 8718696416839 energy-saving lamp  Istruzioni per l`uso  RESPUESTA EN 10 DÍAS HABILES FORMATO DE SOLICITUD  Manual de Usuario del Sistema de Registro y Control de  INFRARED GAS ANALYZER  SmartTRAK Handbuch  226W CS-226C41S/ 113W CS-113C41S・L・R  Samsung KENOX X70 Manuel de l'utilisateur  Solac LV1450  

Copyright © All rights reserved.