AT-ZG01U Gebruikershandleiding / Manual

image

Contents

1. AT ZG01U SET Manual ATAL B V Amp restraat 35 37 NL 1446 TR PURMEREND Postbus 783 NL 1440 AT PURMEREND T 31 0299 630 610 F 31 0299 630 611 E info atal nl www atal nl Content GSS Fal II COU CLIO ae ne ieanieae ne 3 Features amp Display Features and MOdeS cccccssecccssecccesecccescsceecsceneceeeuseeeusceseuecseeuesseeueeeeeuceseueceteuececeneeeeees 3 NS TW SU ae de EN 4 ED DS OAS VDI a a a D ne A abana onset ewan aneionaanederinna beer 5 SEU Sensor Unit Function Instructio essems ee a A S 6 RDU Remote Display Unit Function INSTFUCTION ccccccccesssecccceeesecececeeseeecceeeueececeeuenseceeeseueeceeseegeeeeeteas 7 SNO E a A A E E E nar 7 Carme FOr PIOU e E E E E E ee N 7 installation ASE OS dan one eo te ne ee eee ene eee 8 UN 6 ag ral AT ASTRA oo ee oo ee ar een ee eee eee ee ene ee ere eee 9 SOC INS ON sss cae essen acetic A ache nascent onesie oneal day dene te seeuam et etenne toeseameycss 11 Fault codes amp Troubleshooting Guide cccccccssecccssecccsscccececseeececeecseeuseeeuuceseueceeeueseeeueeeeeneeseuecseeueseneneeees 12 ATA E 2 PAE General introduction Adverse health effects expected Ge y drowsiness i Ain s Time Weight 1000 ppm o e Complaints Average expo Limit lt 8 hour of stiffness and odors Healthy normal outside level Acceptable level Indoor Air Quality IAQ is measure for the quality of air in interiors
2. Indication re Suggested Actions The ambient temperature Er3 has exceeded Er3 flash flash This error will disappear the Fault LED Fault when the temperature 1 Er3 temperature Re LED returns to the range range Le blink between 0 C and 50 C 0 C to 50 C j Buzzer 32 F to 122 F 32 F to beep 122 F Some wrong n cath flash Please unplug the AC measurement Er4 flash Fault adapter and reconnect it or the sensor Fault LED EAn 2 Er4 h LED If the Er4 always as exceeded blink Buzzer cd ag blink appears please contact o p Buzzer with the local dealer ife beep Fault Codes amp Er Troubleshooting EPS ErG flash Please unplug the AC Guide EEPROM Fault adapter and reconnect it 3 ah System oe LED If the Er5 Er6 always Problem Buzzer bee blink appear please contact P Buzzer with the local dealer beep Tanpa Please unplug the AC Er7 adapter and flash reconnected it Check the RJ45 plug is Er7 flash Internal Data Fault LED 4 Er7 Transmission Error blink Buzzer connected into the Blink B INPUT port of RDU if the uzzer beep beep Er7 displays on the RDU only Please unplug the AC Erg adapter and reconnect it The accuracy ilash If the Er8 still appears of CO2 sensor Er8 flash please contact with the Fault 5 Erg May deviate Fault LED LED local dealer from the blink blink Please calibrate the unit actual
3. a safety notice ESC displays on the LCD the fault yellow LED will blink Careful action such as ventilating the space must be taken before entering the room where the SEU is placed To clear the flashing ESC from the LCD use the ReFactSet to restore the unit to the original factory settings or unplug the AC adapter and reconnect it to the power If the communication cable between the SEU amp RDU doesn t connect well like the communication cable loses in the Input port the fault LED of SEU will blink reconnect the cable if the cable is inserted into the output port on RDU after C F flashing one minute the Er7 will flash on LCD Unplug the cable and plug it into the Input port The unit will work normally after corrective action If cleaning places where the SEU is installed first take off rubber cap off and putting it on the position of gas entry Water will not enter into the SEU during cleaning The following picture shows the position changes of the rubber cap Bbz Ab L L co 5 7 Om co 26 Ou gt a gt a e Lan ens me ts coma cms te ve w Ow me gt lt er or ree _ tt te e ia nm Ss gt gt w Bs gt s s a gt _ oom ATA E 6 IAE RDU Remote Display Unit Function Instruction The RDU Remote Dis
4. the comfortable indoor environmental quality can make people feel fresh work efficiency and good for the health The CO2 concentration is the important factor of good indoor air quality People breath in oxygen and breath out CO2 nowadays people often close the windows to avoid noise and enjoy the comfort living and working environment provided by air conditioning systems which results in the fact that the indoor concentration of CO2 is far higher than outdoor average With the high CO2 concentration and non proper ventilation people will feel headaches dull drowsiness loss of concentration and correspond to the high levels of dust chemicals and bacteria in the air Features amp Display Features and Modes e Dual Beam NDIR Non Dispersive Infrared technology is used to measure CO2 concentration up to 50 000 ppm parts per million and electrochemical technology to measure O2 concentration up to 30 e With the SEU Sensor Unit and RDU Remote Display Unit it can RoFactSet CALIBRATING WARMUP t up to 3 RDU for safety notices DAC CZ connect up to or safety notices y gt ous 754 4 e Large digital LCD display clearly indicates the ambient CO2 O2 Concentration and Temperature e Relay output can automatically control a fan to ventilate confined spaces e Audible and visual alarm indications e P54 Water Proof Protection of SEU Sensor Unit except backside when installed on the wall ATA LE Arr 3 Main unit vie
5. 2 Press Enter the four LED s will blink on the SEU and the 3 The four LED s will blink and buzzer will sound simultane Setting the First Alarm parameter 1 Press Mode until the AL1 icon flashes 2 Press Enter the AL1 icon shows on LCD 3 Press Mode to go through 0 5 1 1 5 2 alarm level 4 Press Enter again to save the setting after selection Setting the Second Alarm parameter Obs GG 1 Press Mode until the AL2 icon flashes 2 Press Enter the AL2 icon shows on LCD 3 Press Mode to go through 1 5 2 2 5 3 3 5 4 alarm level 4 Press Enter again to save the setting after selection Note The second alarm level should be higher than the first alarm level when setting with the alarm level parameter ATA FE Aro 9 Using the CALI function Cob J300 CO 4G ef CO 246 1 Press Mode until the CALI icon flashes 2 Press Enter the CALI icon shows on the LCD 3 Press and hold Mode for at least 10 seconds The CALIBRATING icon will flash The calibration will be done automatically After 10 minutes the LCD will display Pass or Fail If Fail please try again Note When do the calibration it is suggested to take SEU outside use the ambient gas for calibration and wait for around 10 minutes until the CO2 reading of SEU doesn t change Then use the 380 420 ppm as the standard CO2 reading Calibrating the unit according to CALI mode instruction user should not breathe t
6. CO2 Buzzer beep B after the calibration If uzzer ie concentration beep the Er8 still appears please contact with the local dealer ATA g 12 AIRE
7. DU If the four LED s blink and the buzzer of SEU and RDU sound simultaneously it indicates that SEU and RDU work normally When the LCD displays a safety icon ESC please take immediate protective action to check if CO2 leakage has occurred We suggest users to do the calibration and thorough function check once within two year to make sure that the AT ZGO1U CO2 Monitor is working properly ATA E MIAE 7 Installation Instructions Please carefully take out the SEU Sensor Unit RDU Remote Display Unit panel holders network cable connector 7 meters communication cable user manual plug lock screws expansion plugs nail cable clips warning paper from the package Step by Step Installation 1 Power Supot Sensor ung ce fan Choose a suitable location to install the SEU Fix the panel holder on the wall with the four screws included the recommend installation height is about 0 45 meters from floor and close to the manifolds and valves as possible Put the SEU on the panel holder make sure they are connected tightly Fix another panel holder in a suitable location the recommend installation height is about 0 45 meters from floor outside the monitored space with screws included Push the RDU onto panel holder and stick the warning paper next to RDU The communication cable is pre wired to the SEU Route the cable to the RDU and fixed the communication cable to the wall by nail cable clips and then plug t
8. RDU to make sure the communication between SEU and RDU works normally 6 Please make sure that the power adaptor is mounted by plug lock tightly so the power adapter cannot be disconnected without using of mechanical tools 7 Do not enter the room directly if there is safety notice ESC displays on the LCD of SEU amp RDU Some careful and protective action must be taken before entering the room where the SEU is installed 8 Please take care of cable connection between SEU and RDU Make sure the cable from SEU is connected into the INPUT port of RDU 9 Please ensure the external power supply is normally supplied to ventilation fan while the relay is working If there has no normally power supply to the fan the relay will not work which may result in potential danger with high CO2 concentration in confined space Caring For Product To make sure to receive the maximum benefit from using this product please observe the follow guidelines 1 Repair Do not attempt to repair the product or modify the circuitry by yourself Please contact your local dealer or a qualified repairman if the product needs servicing 2 Cleaning Disconnect the power before cleaning Use a damp cloth Do not use liquid cleaning agents such as benzene thinner or aerosols as these will damage the device 3 Maintenance We recommend users to test the communication between the SEU and RDU under DIAG function to verify the working conditions for the SEU and R
9. db 10cm Power Supply AC adapter 110 220 VAC Voltage 100 240 VAC F H AC Input requency 50 60 Hz Power 1 W maximum 115 VAC 60 Hz Requirement 2 W maximum 230 VAC 50 Hz AC DC Voltage 6VDC Output Power 3 0 W Peak Input Current 0 5 A from 6 VDC Analog output wo channel linear current output 4 20mA for O2 ZG01Un only RL lt 150Q 4 20mA for CO2 RL lt 1500Q AT ZG01U 0 VDC or 250 VAC max 2A SPST Normally Open Relay Output AT ZG01Un Temperature Range wo Relay output Peak Current lt 2A 30 VDC or 250 VAC SPST Normally Open OC to 50 C 32 F to 122 Display Resolution 0 1 C 0 1 F Display Options C F Accuracy 1 C 2 F when CO2 concentration is below first alarm level Response Time 20 30 minutes case must equalize with environment Operating Temperature 0 C to 40 C 32 F to 104 F 0 95 RH non condensing Storage Temperature 20 to 60 C 4 to 140 F SEU 124 8 x167 7 x 46 57 mm 4 91 x 6 6 x 1 83 inch RDU 85 0 x 117 5 x 33 4 mm 3 35 x 46 3 x 1 32 inch SEU 450 grams 02 RDU 130 grams 11 Fault codes amp Troubleshooting Guide This section includes a list of Frequently Asked Questions for problems you may encounter with the AT ZG01U CO2 Monitor This section includes a list of Frequently Asked Questions for problems you may encounter with the AT ZG01U CO2 Monitor LCD Description ies RDU No fists of the fault SEU
10. dicate the CO2 leakage once the CO2 r level is above 3 0 ATA E IAE 5 SEU Sensor Unit Function Instruction The SEU Sensor Unit should be placed in a room where the CO2 is likely to accumulate such as a room where CO2 is stored like an area with CO2 beverages The large LCD displays the ambient CO2 concentration and the temperature The SEU has the DIAG AL1 AL2 CALI ReFactSet function The DIAG function executes communication tests between the SEU and RDU The user can do the calibration under the CALI mode when necessary If data setting is done incorrectly the user can use the ReFactSet back to the original factory setting There are two alarm levels the alarm level is adjustable the first alarm level is with parameter 0 5 1 1 5 2 the default first alarm level is 1 5 The second alarm level is with parameter 1 5 2 2 5 3 3 5 4 the default second alarm level is 3 When the AT ZGO1U CO2 Monitor detects CO2 concentration that exceeds the first alarm level the red 1 LED will blink and the buzzer will sound intermittently the relay will be triggered If the concentration of CO2 continues to rise above the second alarm level the red 1 and red 2 LED s will flash together and the tempo of the buzzer will increase The green LED will light continuously when the power is normally supplied Warning If the ambient CO2 concentration reaches the second alarm level on SEU amp RDU there will be
11. he cable into the input port on the RDU Communication is now ready between the SEU and RDU The AT ZGO1U CO2 Monitor has one relay output The relay cable is pre wired to SEU The relay can control a fan or blower to ventilate the monitored space when necessary The relay will be triggered when the CO2 concentration exceeds the first alarm level After finishing the installation Connected the AC power adapter into the electrical supply outlet Mount the Plug lock by expansion plugs so that the power adapter cannot be disconnected without use of mechanical tools When the power is connected The SEU and the RDU will begin to work Please use the DIAG function to verify the communication between SEU and RDU the four LED will blink and buzzer will sound on SEU amp RDU After the communication is ready the content of display is same on SEU amp RDU Repeater J Fan for J Wanmng paper _Gas Cylinders en Cellar Door Mount the plug lock Customizing settings When power has been connected the SEU and RDU will begin to monitor the CO2 concentration and the temperature In order to the get the timely alarm safety information and meet the personal requirements it is advisable to set up the customizing parameter when necessary Temperature C F 1 Press Enter to switch between C and F temperature Using the DIAG function c game CYB SY gem CYB 1 Press Mode until the DIAG icon flashes
12. oward to SEU during the calibration process as the CO2 from the user will affect the CO2 reading of SEU Using the ReFactSet function 900z _ mo YES 10 ek set Ref mctSet Per 4 HES P 2467 P 246 1 Press Mode until the CALI icon flashes 2 Press Enter and then press Mode to choose either Yes or No 3 Press Enter again to save the setting after selecting Note If the user sets the data or calibrates the sensor incorrectly use the ReFactSet recover the factory Setting to come back the default factory setting Specifications Method Dual Beam NDIR Sample Method Diffusion or flow through 50 200 ml min Performance CO2 Power Supply amp Relay Output Temperature specification Dimensions Operating Conditions Weight including batteries Measurement Range 0 50 000ppm 5 display Display Resolution 10 ppm Accuracy Repeatability Annual Drift Temperature Dependence 100 ppm or 5 of reading whichever is greater 20 ppm 400 ppm lt 20 ppm Year 400ppm 0 2 of reading per C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 0 13 of reading per mm Hg Response Time lt 60 seconds for 90 response to step change AL1 First Alarm Level AL2 Second Alarm Level 5000ppm 1 1 5 2 Default AL1 1 5 1 5 2 2 5 3 3 5 4 Default AL2 3 Warm Up Time lt 60 seconds at 22 C Sound Alarm 80
13. play Unit should be placed outside the room when in use The RDU is connected to the SEU with a wire that has a maximum length of 25 feet The RDU should be placed where it can be conveniently observed before entering the room where the SEU is located The RDU is a repeater and displays the measurements made by the SEU on an easy to read digital LCD along with important safety information The RDU has DIAG function The DIAG can test the communication between the SEU and RDU Resetting the AT ZGO1U CO2 Monitor is only available from SEU Safety Notes Warning Your safety is very important to us To ensure to use the product correctly and safety please read these warnings and the entire User Manual before using the product Otherwise the protection provided by the equipment may be impaired These warnings provide important safety information and should be observed at all times 1 Please handle the device carefully do not subject the product to impact or shock 2 Donot submerge the product into water or any liquid Water may cause electric shock fire or malfunction which may result in damage 3 Do not place the unit or the adaptor near a heat source Heat can cause distortion of the unit which may result in an explosion or fire 4 Donottouch the exposed electronic circuitry of the device under any circumstances as there is the dangerous of electric shocks 5 Please use the DIAG function to verify the communication between SEU and
14. w Sensor unit ZT ST IONMONWw X TOnNMnooOw LCD Display Yellow LED Fault indication Red 2 LED AL2 Red 1 LED AL1 Green LED Power indication Reset Button Mode Button Enter Button Communication Cable to RDU Relay output Power Supply Rubber Cap Gas Entry Buzzer Remote Display Unit OPQR xSs lt CHYARO VO Green LED Power indication Red 1 LED AL1 Red 2 LED AL2 Yellow LED Fault indication LCD Display Enter Button Mode Button RJ45 Plug for next RDU RJ45 plug for SEU input Buzzer LCD Display Symbol symbol CO2 Concentration ppm Parts Ambient CO2 concentration Per Million gi b J Temperature Celsius Ambient temperature in Celsius i P 4d Temperature Fahrenheit Ambient arte Fame in Fahrenheit ol _ ne MUTE Alarm Aum strongman function icon Test communications between the SEU and Diagnose RDU The relay will be triggered when CO2 g concentration exceeds the first alarm level First Alarm level the Red 1 LED will flash and buzzer will sound Safety Notice ESC displays on LCD when AL 2 CO2 concentration exceeds the second alarm Second Alarm level level The Red 1 amp Red 2 LEDs will flash and buzzer will sound To calibrate the CO2 sensor when the Calibration accuracy deviates from the actual CO2 concentration To recover factory default settings and cancel ReFactSet Recover Factory Setting any customize settings To in