1. User manual What A rPatrol Lite does AirPatrol Lite is an air conditioner A C controller you operate with a mobile phone It is compatible with all major manufacturers air conditioners and all mobile phones see AirPatrol eu for the complete list The easiest way to use AirPatrol Lite is with a Smartphone using the AirPatrol app downloadable from the Google Play for Android phones Windows Store for Windows Phone 8 or App Store for iPhone It can also be controlled with regular mobile phone text messages SMS AirPatrol Lite allows you to have long distance control over the mode of the A C room temperature and fan speed settings Indicator light The controller has 1 LED indicator and 1 button for easy setup It has also 2 infrared LEDs that transmit your commands to the air conditioner LED Controller busy Controller switched OFF no power normal status no network DataCall session is active Button SIM card Use a straightened paper clip or something similar to push the recessed button Make sure you disable the PIN code of the SIM card you use in AirPatrol Lite turns the air conditioner ON OFF Use the TEST button to confirm that Make sure the SIM card you use in AirPatrol Lite can access 2G network the IR beam from the controller reaches the air conditioner AirPatrol Lite is not compatible with SIM cards that use only 3G network resets the controller clears settings A Make sure that you hav
2. Pump mode Fan AUTO MIN NORM MAX Fan speed Temp xxC Pump temperature Controller VERSION report explanation Al rPatro ite comma nd S h eets SMS format Explanation Ver version number AirPatrol Lite firmware version Air conditioner ON OFF Pump ON OFF Pump status ON OFF l Command SMS Air conditioner function GSM sa cell GSM signal strength 0 31 99 and GSM area on info 1 local network 5 roaming ON Pump ON Life mm dd Controller run time months days OFF Pump OFF Commands Error MESSAGES Command SMS Air conditioner function AUTO AUTO 20 C fan NORM seende DRY DRY 20 C fan NORM SMS will be sent if there was an error in your command COOL COOL 20 C fan NORM For example an SMS cool19max receives the response Error command HEAT HEAT 20 C fan NORM cool19max Note that AirPatrol Lite will only return your incorrect command T8 Tomode without suggesting a correct one the error in the example is the absence of spaces between commands T9 19 mode T10 T10 mode Error pump command text SMS means the operation T8 T9 T10 is not available for the specified pump When AirPatrol Lite fails to send an SMS it will retry after 1 minute For more information please visit www AirPatrol Lite eu For support please contact us support AirPatrol Lite eu I 119 727 A
3. SMS Command ON turns air conditioner on SMS Command OFF turns air conditioner off turns air conditioner on turns air conditioner off Commands The range of air conditioner temperature values AirPatrol Lite controls is 16 30 C default 20 C and the fan speeds are MIN NORM MAX default is NORM After selecting a mode AUTO DRY COOL HEAT T8 T10 air conditioner is turned on with 20 C default temperature and normal fan speed The pump can be assigned different temperature and fan speed values with AirPatrol Lite For example the SMS COOL 19 MAX orders the pump to cool until 19 C and fan at maximum speed When you change an air conditioner function AirPatrol Lite always responds with an SMS that reports its STATUS AUTO 6 MIN ORY 15 MORM COOL ne MAX HEAT co 0 Te 13 MO Advanced setup Combine the pump mode room temperature and fan speed values for a For the brave home atmosphere you like the best A r conditioner model setup The pump can be chosen on 3 levels of precision 1 The precise name of the pump the manufacturer and the model This is recommended for the most efficient operation 2 Pump manufacturer If you only choose the pump manufacturer functions T8 T9 T10 will not be checked and the command will be sent even if the pump does not have 18 19 110 mode If the exact pump model is not listed on our webpage or in this manual AirPatrol Lite m
4. ay or may not work with the air conditioner for which the AirPatrol Lite manufacturer will not be held responsible 3 All pump models If you choose All pump models SMS 950 then all supported brands IR commands will be sent to the pump and AirPatrol Lite can be used without choosing the pump more precisely Setup SMS Air conditioner model and T8 T10 Setup SMS Air conditioner model and T8 T10 command series command series Report messages You can send report requests to AirPatrol Lite about your air conditioner status controller status and the setup of the controller Report messages are sent only to the sender of the request SMS SMS Response SMS example command command you send function Pump status STATUS request Pump ON Mode HEAT Fan MAX Temp 21C Controller Ver 1 01bxx Device name Pump ON OFF GSM sq cell VERSION status request Life mm dd SETUP Setup request Device name you send you send 950 All pump models T8 T10 95E Samsung 951 Fujitsu T10 Sor Sharp T10 953 Panasonic T8 956 General T10 954 Mitsubishi Electric T10 95H Fuji T10 955 Bosch T10 95J Altech T8 956 IVT T10 957 Mitsubishi Heavy 958 LG 19 95A Electrolux 95B Midea 18 95 Daikin T10 95D Hitachi Pump STATUS report explanation Pump STATUS report Response SMS example SMS Format Pump ON OFF Pump ON OFF Mode AUTO DRY COOL HEAT T8 T10
5. e previously disabled the SIM card PIN code Insert SIM card as shown into AirPatrol Lite ze B Plug the adapter into the socket under A the AirPatrol Lite Installing A rPatrol Lite AirPatrol Lite should be mounted on the wall to the right of your air conditioner s indoor unit see fig 1 with its IR transmitter pointing down This way the IR beam is reflected from the floor and reaches the air conditioner s sensor most efficiently Other mounting configurations are possible too as long as IR transmission from the controller to the pump works NB Thick carpets and dark floors can distort the IR beam Make sure the IR beam reaches the pump s sensor by using the controller s Test function Fig 1 On the right side of the indoor unit Fig 2 Attached to the right side of the indoor unit Fig 3 Beneath the indoor unit Fig 4 On the wall opposite to the indoor unit Fig 5 On a ledge opposite to the indoor unit Rg 0 7 Do not place AirPatrol Lite on the left side of the indoor unit Indoor unit s internal condenser might block AirPatrol Lite s signal Testing A rPatrol Lite To see if AirPatrol Lite can send commands to your air conditioner turn off the pump and press the controller s button shortly When the connection is established AirPatrol Lite turns the pump on with its last settings and you can proceed using the controller Turning air conditioner ON OFF