Home
        Measuring equipment for the Sunny Central
         Contents
1.              Bridge terminal 1 with terminal 2 terminal 12 on the sensor  Bridge terminal 3 with terminal 4 terminal 11 on the sensor  or   Terminal 5 terminal 12 on the sensor  Terminal 6 terminal 11 on the sensor  or   Terminal 7 terminal 12 on the sensor  Terminal 8 terminal 11 on the sensor          User Manual SCMess 10 BE3406 Page 13    Calibrating the Sunny Central Control SMA Technologie AG    5 Calibrating the Sunny Central Control    5 1 General Information    To properly calibrate the data logger for the irradiation sensor  the analog measuring  channels are programmed directly on the Sunny Central Control in the menu item  Set   up   Interfaces   Analog In      To calibrate the Sunny Central Control  the voltage value specified on the  type plate of the RA100 T sensor is required for an irradiation of 1000 W   m   Please take note of this before installing the sensor     5 2 RA100 T    Since the RA100 T consists of two sensors  irradiation and temperature   two sensors  must be programmed at this point     Irradiation Sensor    A suitable measuring range must first be set in the first line under the  Function  column   In case of the irradiation sensor in the RA100 T  the measurement tolerance range  would be  500 mV     The name of the channel can be precisely defined in the next line  e g  irradiation      The measurement unit of the channel can be specified in the third line  here  W   m     The gain V is calculated from the value specified on the type plate fo
2.    Terminal 3 white wire 1  PT100 original wire   Terminal 4 white wire 2  PT100 duplicated wire           PT100 temperature sensor connection to   Z5 X5  in a two wire system                            Bridge terminal 1 with terminal 2 red wire  PT100 original wire   Bridge terminal 3 with terminal 4 white wire  PT100 original wire   or   Terminal 5 red wire  PT100 original wire   Terminal 6 white wire  PT100 original wire   or   Terminal 7 red wire  PT100 original wire   Terminal 8 white wire  PT100 original wire                 Page 12 SCMess 10 BE3406 User Manual    SMA Technologie AG Electrical Wiring and Sensor Connection    4 3 PT100 U    The PTIOO U ambient temperature sensor consists of a PT100 sensor resistor that is  embedded in glass and is installed in an IP65 plastic housing  The ambient temperature  sensor is mounted using two mounting holes     The PT100 U temperature sensor allows a measurement using either a two wire or four   wire system  The connection cable is not included in the delivery and is routed into the  housing interior through a PG screw fitting     Here  we also recommend installing in a four wire system  Q    PT100 temperature sensor connection to   Z5 X5  in a four wire system                   Terminal 1 terminal 14 on the sensor  Terminal 2 terminal 12 on the sensor  Terminal 3 terminal 13 on the sensor  Terminal 4 terminal 11 on the sensor             PT100 temperature sensor connection to   Z5 X5  in a two wire system                     
3.    Terminal 4 brown wire 2  PT100 duplicated wire              Page 10 SCMess 10 BE3406 User Manual    SMA Technologie AG Electrical Wiring and Sensor Connection    A PT100 connection in a two wire system          V I measurement PT 100    xN  Terminal block    A PT100 connection in a four wire system      measurement V measurement PT 100    Terminal block                               PT100 temperature sensor connection to   Z5 X5  in a two wire system  Bridge terminal 1 with terminal 2 yellow wire  PT100 original wire   Bridge terminal 3 with terminal 4 brown wire  PT100 original wire   or   Terminal 5 yellow wire  PT100 original wire   Terminal 6 brown wire  PT100 original wire   or   Terminal 7 yellow wire  PT100 original wire   Terminal 8 brown wire  PT100 original wire                 User Manual SCMess 10 BE3406 Page 11    Electrical Wiring and Sensor Connection SMA Technologie AG    4 2 PT100 M   The PT100 M temperature sensor consists of a PT100 sensor resistor that is embedded  in a metal tube  The sensor can be stuck directly to the back of the module using the  provided dualcomponent thermal adhesive and thus determine the module  temperature     Here  we also recommend installing in a four wire system        The connection is established using a 3 meter long cable in a two wire system        PT100 temperature sensor connection to   Z5 X5  in a four wire system                Terminal 1 red wire 1  PT100 original wire   Terminal 2 red wire 2  PT100 duplicated wire
4.    User Manual SCMess 10 BE3406 Page 9    Electrical Wiring and Sensor Connection SMA Technologie AG    4 Electrical Wiring and Sensor Connection    The sensors are connected to the  Z5 X5 terminal        4 1 RA100 T    Irradiation Sensor    In this case  an analog inputis used as the voltage input  To do so  the positive pole of  the reference cell  green wire  is connected to terminal 5 or 7 and the negative pole of  the reference cell  white wire  is connected to terminal 6 or 8                       Irradiation sensor connection to   Z5 X5    Terminal 5 green wire  irradiation     Terminal 6 white wire  irradiation     or   Terminal 7 green wire  irradiation     Terminal 8 white wire  irradiation                   PT100 Temperature Sensor    To also ensure the accuracy over greater distances  we recommend connecting the  PT100 sensor resistor in a four wire system  For this purpose  the connecting wires of the  PT100 sensor resistor are duplicated directly nextto the RA100 T sensor and thus a total  of 6 wires  2 wires for the irradiation sensor and 4 wires for the PT100 temperature  sensor  lead to the Sunny Central  The connection is established without using bridges  on the terminal strip in accordance with the following connection plan                       PT100 temperature sensor connection to   Z5 X5  in a four wire system   Terminal 1 yellow wire 1  PT100 original wire   Terminal 2 yellow wire 2  PT100 duplicated wire   Terminal 3 brown wire 1  PT100 original wire
5.   statutory safety regulations in the deployment location   e Ignoring safety warnings and instructions contained in all documents relevant to the product   e Operating the product under incorrect safety or protection conditions   e Altering the product or supplied software without authority   e The product malfunctions due to operating attached or neighboring devices beyond statutory limit values    e In case of unforeseen calamity or force majeure  Software licensing  The use of supplied software produced by SMA Technologie AG is subject to the following conditions     This software may be copied for internal company purposes and may be installed on any number of  computers  Supplied source codes may be changed or adapted for internal company purposes on your own  responsibility  Drivers may also be transferred to other operating systems  Source codes may only be published  with the written permission of SMA Technologie AG  Sub licensing of software is not permissible     Limitation of liability  SMA Technologie AG rejects any liability for direct or indirect damages arising from the  use of software developed by SMA Technologie AG  This also applies to the provision or non provision of  support activities     Supplied software not developed by SMA Technologie AG is subject to the respective licensing and liability  agreements of the manufacturer     Trademarks    All trademarks are recognized even if these are not marked separately  Missing designations do not mean that  a
6.  product or brand is not a registered trademark     SMA Technologie AG   Hannoversche Stra  e 1 5   34266 Niestetal   Germany   Tel   49 561 9522 0   Fax  49 561 9522 100   www SMA de   E mail  info SMA de      2005 SMA Technologie AG  All rights reserved     Page 18 SCMess 10 BE3406 User manual    Sales  Solar Technology    SMA Technologie AG  Hannoversche Strasse 1 5  34266 Niestetal  Germany  Tel    49 561 9522 4000  Fax   49 561 9522 4040  E Mail  Info SMA de  Freecall   800 SUNNYBOY  Freecall   800 78669269         AA  PR 4  Innovation in Systems Technology A A P    for the Success of Photovoltaics    
7. AMT    Measuring equipment for the Sunny Central          User manual       Version 1 0   SCMess 10 BE3406    SMA Technologie AG    Index   1 Explanation of the Symbols Used              5  2 Introduchon s eiasanase rennen 6  3 Product Presentation               2eee eens 7  4 Electrical Wiring and Sensor Connection        10  5 Calibrating the Sunny Central Control          14  6 Overvoltage Protectors                008  16    User manual SCMess 10 BE3406 page 3    SMA Technologie AG    page 4 SCMess 10 BE3406 User manual    SMA Technologie AG Explanation of the Symbols Used    1 Explanation of the Symbols Used    In order to ensure optimal use of these instructions  please note the following  explanation of symbols used     This symbol indicates an example     procedure or operation more difficult     This symbol indicates a fact which  if not observed  could result in damage  to components or represent a danger to persons  Read these passages  especially carefully     This symbol indicates a notice which  if not followed correctly  will make the Q    User Manual SCMess 10 BE3406 Page 5    Introduction SMA Technologie AG    2 Introduction    The Sunny Central enables the direct connection of analog and digital sensors for  determining environment data  such as global radiation or temperature     e Irradiation sensor with integrated module temperature sensor RA 100 T  e Temperature sensor for measuring the module temperature PT 100 M  e Temperature sensor for measuring the 
8. ambient temperature PT 100 U       The range of sensors comprises  among others  the following measurements     Page 6 SCMess 10 BE3406 User Manual    SMA Technologie AG    3 Product Presentation    Product Presentation    3 1 Irradiation Sensor RA100 T                         Description Parameters  Voltage tolerance max  5    Temperature sensor PT100  Reti00 PT100 basic series  Tolerance class 1  3B  Dimensions 122x122 x20 mm  Cable length approx  5 m  4 wires        Calibration value    see type plate                            Ambient temperature 30       450  C   W ire function   Green irradiation sensor     W hite irradiation sensor     Yellow PT 100 temperature sensor  Brown PT 100 temperature sensor          User Manual    SCMess 10 BE3406    Page 7    Product Presentation    SMA Technologie AG    3 2 PT100 M Temperature Sensor                                  Description Parameters  Connection two wire system up to 10 m  M ounting installation using the provided dual   component thermal adhesive  RPT100 PT100 basic series  Tolerance class 1  3B  Dimensions 30x6x6 mm  Cable length approx  2 5 m  2 wires   M easuring range 20    110  C             Page 8 SCMess 10 BE3406    User Manual    SMA Technologie AG Product Presentation    3 3 PT100 U Temperature Sensor                                  Description Parameters  Connection Four wire system  Housing IP 65  Retioo PT100 basic series  Tolerance class 1  3B  Dimensions 100 x52 x 67 mm  M easuring range 30    80  C    
9. r the measurement  voltage at1000 W m  and at25  C asfollows     V  1000   measurement voltage at1000 W m   The value for the offsetis 0   PT100 Temperature Sensor    The suitable temperature unit must first be setin the first line under the  Function  column   In case of the temperature sensor of the RA100 T  that would be   C     The name of the channel can be precisely defined in the next line  e g  module  temperature      The gain and offset do not require calculating     Page 14 SCMess 10 BE3406 User Manual    SMA Technologie AG Calibrating the Sunny Central Control    5 3 PT100 U  PT100 Temperature Sensor    The suitable temperature unit must first be setin the first line under the  Function  column   In case of the temperature sensor of the RA100 T  that would be   C     The name of the channel can be precisely defined in the next line  e g  module  temperature      The gain and offset do not require calculating     5 4 PT100 M  PT100 Temperature Sensor    The suitable temperature unit must first be setin the first line under the  Function  column   In case of the temperature sensor of the RA100 T  that would be   C     The name of the channel can be precisely defined in the next line  e g  module  temperature      The gain and offset do not require calculating     User Manual SCMess 10 BE3406 Page 15    Overvoltage Protectors SMA Technologie AG    6 Overvoltage Protectors    To protect the Sunny Central against external overvoltage  the sensors should be  connected u
10. sing overvoltage protectors  O vervoltage protectors can be ordered  optionally     W e recommend the following overvoltage protectors   PT 100    BLITZREDUCTOR CT  BCT MODBE 5  DEHN item no   919 506   919 620    Analog Signals    BLITZREDUCTOR CT  BCT MOD BD 30  DEHN item no    919 506   919 644       Page 16 SCMess 10 BE3406 User Manual    SMA Technologie AG Overvoltage Protectors    User Manual SCMess 10 BE3406 Page 17    Legal Restrictions SMA Technologie AG    The information contained in this document is the property of SMA Technologie AG  Publishing its content   either partially or in full  requires the written permision of SMA Technologie AG  Any internal company copying  of the document for the purposes of evaluating the product or its correct implementation is allowed and does  not require permission     Exclusion of liability  The general terms and conditions of delivery of SMA Technologie AG shall apply     The content of these documents is continually checked and amended  where necessary  However   discrepancies cannot be excluded  No guarantee is made for the completeness of these documents  The latest  version is available on the Internet at www SMA de or from the usual sales channels     Guarantee or liability claims for damages of any kind are exlcuded if they are caused by one or more of the  following     e Improper or inappropriate use of the product   e Operating the product in an unintended environment   e Operating the product whilst ignoring relevant
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Tecnostyl PBM001 document holder  IHクッキングヒーター CI 261 112 CI 481 112 CI 490 112    News Release  MAnGve: Um Modelo para apoio à Governança de TIC inspirado no  Human Motion Detection Using Passive Infra Red Sensor  intext:Bedienungsanleitung filetype:pdf  User Manual  CAT5 • 1000HD    Copyright © All rights reserved. 