1. lt CE et n Test Ch 1 10 Press Ok gt Preheat setup D1210 have individual channel preheat values which can be set in this way Enter Unit Setup gt Preheat Ch1 0 and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt Remember that you can toggle between channel no and channel value using lt and gt keys The preheat value for selected channel will blink Change the settings by press ing Up Down keys If you want to change another channel preheat value press lt key and change the channel number When you have set all preheats to desired values press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without saving the changes press lt key Note The max preheat value is 50 and in the on off mode the preheat is shut off DMX Address setup D1210 have individual channel DMX addresses To set these addresses enter Unit Setup gt Ch 1 DMX Addr 01 and press Menu key The channel number will start to blink Select the desired channel by pressing Up Down keys and then press gt Change the settings pressing Up Down keys If you want to change another channel address value press lt key and change the channel number Press Menu key and the Save Changes view will appear
2. e Never cover the ventilation slots of the device while it is on Do not place the device in locations that are subject to direct sunlight If you do it may overheat and become irreparably damaged e Never operate the dimmer pack in the vicinity of heat sources such as cookers heating ele ments or other heat producing installations e Do not place open fire sources such as candles on the device e Before a storm and or a thunderstorm with a risk of lightning disconnect the device from the electrical power source AN Risk of personal injury e Keep children away from the power cord and the device Children frequently underestimate the dangers of electrical devices e Provide a stable location for the device e Do not operate the device if it has sustained a fall or is damaged Have the device checked or if necessary repaired by qualified technicians ZA ATTENTION e Damages caused by the disregard of this user manual are not subject to warranty Neither the manufacturer nor the importer will accept liability for these kind of damages or any resulting damages defects or problems The electric connection must only be carried out by a qualified electrician All electric and mechanical connections must comply with European safety norms Specifications AC INPUT e sgt eerenseugee 230V AC 50 60Hz 1 2 or 3 phases max 32A phase LOAD 12 channels max 10A channel E Output connector 2 x Harting 16 pin
3. DMX Gonal DMX 512 1990 DMX connectors input XLR 5 pin male WEE output XLR 5 pin female Dimension 19 2U 483 L x 90 H x 410 D mm Weight OPPA 14 9 kg Our products are subject to a process of continual further development Therefore modifications to the technical features remain subject to change without further notice Never throw the device into the regular household waste at the end of its useful life R This product is subject to the European Directive 2002 96 EC zez e Dispose of the device through an approved disposal centre or at your community waste facility e Observe the current existing regulations In case of doubt contact your disposal facility RY e The packaging is certified via a dual system Take all packaging materials to an environ R mentally friendly disposal facility in compliance with the local regulations e Never submerse the device in water or any other liquid Don t let any liquid get into the housing This would damage the unit and cause a short circuit e Before cleaning the device you must disconnect it from the mains Clean the surface of the device only with a slightly damp cloth Never use petrol solvents or any aggressive cleaners These could damage the surface of the unit s housing gt Digital signal interface DMX512 1990 gt Each channel have it s own DMX address gt Individual preheat on every channel 0 15 gt Individual contr
4. on LCD To save changes press Menu key to quit without saving the changes press lt key Note Changing the DMX address for Ch1 will modify all addresses If you want to modify the address for each channel first set Ch1 address and after that set the others addresses Control curve setup D1210 have 5 control curves for each channel e Linear Sqrt Curve1 dimmer mode e On off switch mode The channel will be on full when its value passes over 64 And the chan nel will be turned off when its value drops below 32 Note The individual channel settings must be set before turning on the circuit breaker Some non dim ming lamps may be damaged if they are used in dimmer mode To select the control curve enter Unit Setup gt Ch Curve and press Menu key The channel number will start to blink Select the desired channel by pressing Up Down keys and then press gt the curve for selected channel will blink Change the settings by pressing Up Down keys If you want to change another channel preheat value press lt key and change the channel number When you have set all channel curves press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without saving the changes press lt key You can test channels set individual channel value using Test Mode Enter Test Ch 1 0 and press Menu key The channel number will start to blink Select the de sire
5. D1210 Owner s Manual 12 CHANNEL DIGITAL DIMMER PACK s z PEPER EDD ERE UI Game z D m FH m 5 kani e e z sr chs F i 3 Wi e 1 14 Af o 58 g Waa E Ze Chii iwo HM3 ER Te Ligi anim owent De sent T 3 gie H R Chi2 LIVE ELLE TELL a STAR Notes on safety For your own safety you must read through this chapter at first completely AN O AN Risk of electrical shocks e Only connect the device to a mains power supply that complies to the technical specifications given in this manual e Do not operate the device if the power cord or the mains plug are damaged e Never submerse the device in water Wipe it with a slightly moistened cloth only e Do not expose the device to rain and never use it in a damp or wet environment Indoor use only Make sure that the power cord never becomes wet or moist during use e Under no circumstances may you open the device housing Should you do so your safety would not be assured and the warranty will become void There are no operational components what soever inside only really high voltage that can give you a deadly shock e Do not place objects containing fluids e g flower vases or beer bottles on or near the device e Notice regarding disconnection from mains power To completely disconnect the device from mains power you must pull the plug from the power socket For this re
6. ason the device should be placed in a position where unobstructed access to the power socket is assured at all times so that in an emergency you will be able to immediately pull out the plug To eliminate the risk of fire you have to completely disconnect the power plug from the power socket when the device is not going to be used e Always grasp the power cord by the plug Do not pull on the cord itself and never touch the pow er cord with wet hands as this could result in a short circuit or an electrical shock Do not place the device speakers or anything else on the power cord and make sure that it does not become clamped Never tie Knots in the power cord and do not bind it together with other cables Lay the power cord so that no one can step on or stumble over it Adamaged power cord can cause a fire or an electrical shock Check the power cord from time to time Should it become damaged contact our customer service department to have it replaced e Always operate the device only on a properly wired and correctly earthed socket see specifica tions never sever the power cord s earth wire Otherwise a LIFE THREATENING situation ex ists e Never use this device in places where it is subject to gt excessive vibrations and or impacts gt temperatures above 30 C 100 F or below 5 C 40 F gt extreme low or high humidity ideal humidity is between 35 and 80 ZN Risk of fire e Never leave the device unattended during operation
7. ctions powered by a single phase Note It is recommended to power up all three phases do not leave any dimmer section unpowered even if you don t use it Once you have powered the unit the phase indicator LED s will light and the LCD will display after a second STAIRVILLE D1210 DIGITAL DIMMER This means that D1210 is ready to be used The green LED s on the front panel will show the intensity for channels Turn on the Circuit Breakers for the channels you want to use and the lamps will light up Note It is recommended to set up the unit see next pages before you turn on the Circuit Breakers down up StdBy EH aw Unit Setup Press Ok gt down up Menu DMX Addr Chxx 01 Press Ok lt down up Preheat Ch1 0 Press Ok lt ZEN up Ch1 Curve Linear Press Ok lt down up Ch1 Limit 100 Press Ok lt down up Stairville D1210 StandBy Mode Digital Dimmer Press StdBy Key lt lt 9 Save Changes Yes OK NO lt CE y up ELUR Channel 1 100 Press lt d pany t er DMX Signal Ok Press lt d anny T L1 temp 32Deg Press lt d own up Version 1 0 0 Press lt down Unit Status Press Ok gt down up
8. d channel by pressing Up Down keys and then press gt Remember that you can toggle between channel no and channel value using lt and gt keys The channel value will start to blink Change the settings by pressing Up Down keys If you want to change another channel value press lt key and change the channel number When you want to exit press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without saving the changes press lt key Limiter setup D1210 have individual voltage channel limit values for prolonging bulb life This can be set in this way Enter Unit Setup gt Limit Ch1 255 and press Menu key The channel number will start to blink Select the desired channel pressing Up Down keys and then press gt Remember that you can toggle between channel no and channel value using lt and gt keys The Limiter value for selected channel will blink Change the settings by pressing Up Down keys If you want to change another channel limiter value press lt key and change the channel number When you have set all limits to desired values press Menu and the Save Changes view will appear on LCD To save changes press Menu key to quit without saving the changes press lt key Note The minimum limiter value is 200 and in the on off mode the limiter is shut off You can see the value of each channel of the D1210 entering U
9. nit Status gt Channel 1 68 and press Menu key The channel number will start to blink To change the current channel press Up or Down keys To leave this menu press Menu DMX status You can check DMX status entering Unit Status gt DMX Signal If the DMX reception is OK the LCD will display DMX signal OK If there s something wrong with DMX signal the LCD will display No DMX signal Note Changing the status of DMX reception will be displayed by blinking for 3 seconds e g when you turn on off the DMX console Displaying unit temperature You can view the D1210 internal temperature for each phase module entering Unit Status gt Unit Temp 34Deg When the temperature exceeds 45 the corresponding cooling fan will start The fan speed will increase with internal temperature until 65 when the fan speed will be max If the temperature of any of the 3 modules reach 95 then the D1210 enters overheat protection until the temperature for that module drops below 80 In this situation the channels corresponding to the overheated module will be shut down and the LCD will display blinking L Overheat Unit Overheated Note To avoid overheating do not cover the cooling fans and ensure adequate ventilation 2010 I Musikhaus Thomann 30 P ie ag Ate
10. ol curve on every channel Switch Linear Sqrt gt Adjustable voltage limit for every channel gt Auto frequency tracking 45 65 Hz gt Test mode gt LCD display gt Internal temperature displaying for each Phase module gt Variable fan speed corresponding to internal temperature for each phase module b Overheat protection for each phase module 2 mi KANAAN Pid NANANG 7 d RW ISJP a ja MA uii el D D Si gl FAZY LoVe f a Des m pe m see ras 1 H Eha Cha a r 2 al ii g 3 17 D EI M 7 Ge chr 5 KE KE JI I HK io RAE gr Ef Cha Circuit Breaker DMX Signal output Phase LED indicator DMX Signal input Channel LED indicator Control Keys LCD Display d L 4 1 4 p R e kes j 4 L a eee eee gt A z e0c0 e BE eeceececei f Wi e eege eh Ch e 8 z fey gt a im AC Power Output Cooling Fan Main AC Power Input Installation Power up Plug the 12 lamps into the Harting sockets as is shown on the back panel Insert the DMX cable in the corresponding Inputs Unwrap the power cord and plug into a 3x230V socket capable of delivering 32A per phase D1210 have three sections phases named L1 L2 L3 They can be powered in several modes e each section powered by its individual phase e one section powered by one phase and the other two powered by another phase e all se