User Manual M-Bus from/to Modbus on RS232/RS485

image

Contents

1. 2 56 inch Housing PVC Weight 200g Approx Figure 17 Mechanical dimensions scheme for HD67029M 485 160 ADFweb com Srl IT31010 Mareno Treviso User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485_ENG Revision 2 052 Page 28 of 31 95 mm 3 74 inch Ee a 106 mm 75 mm 2 95 inch 4 17 inch Housing PVC Weight 200g Approx Figure 16 Mechanical dimensions scheme for HD67029M 232 250 95 mm 3 74 inch ay AALT E 106 mm 75mm 4 17 inch 2 95 inch Housing PVC Weight 200g Approx Figure 18 Mechanical dimensions scheme for HD67029M 485 250 INFO www adfweb com Phone 39 0438 30 91 31 Aib Industrial Electronic Devices ORDERING INFORMATIONS User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485_ENG Revision 2 052 Page 29 of 31 The ordering part number is formed by a valid combination of the following HD67029M xxx yyy Order Code Order Code Order Code Order Code Order Code Order Code Order Code Order Code Order Code Order Code ADFweb com Srl IT31010 Mareno Treviso L Maximum number of slaves supported 20 up to 40 standard slaves 1 5mA consumption connected to M Bus 40 up to 40 standard slaves 1 5mA consumption connected to M Bus 80 up to 80 standard slaves 1 5mA consumption connected to M Bus 160 up to 160 standard slaves 1 5mA consumption connected to M Bus 250 up to 250
2. HD67029M 485 it is possible to check the field RS232 or RS485 In the field Baudrate the baudrate of the serial line in use is defined In the field Parity the parity of the serial line is defined In the field ID Dev the ID for the Modbus side is defined In the subsection Protocol it is possible to select the protocol to use in Modbus line from the following e Modbus RTU e Modbus ASCII e JBUS e Binary simple protocol defined by Us whose functions are described in the document Simple Protocol downloadable at www adfweb com download filefold Simple Protocol ENG pdf e ASCII simple protocol defined by Us whose functions are described in the document Simple Protocol downloadable at www adfweb com download filefold Simple Protocol ENG pdf 4 44 The means of the fields for M Bus are Inthe field Baudrate the baudrate of the M Bus net is defined Inthe field Parity the parity of the M Bus line is defined If the field M Bus Poll on request is checked the Gateway makes the request only if a Modbus register is requested otherwise if Cyclic request is checked the Gateway makes the request in M bus network each time the time defined under passes In the field Delay insert a time expressed in seconds This time is used for the Cyclic request Baudrate 115200 id Parity EVEN ID Dev 3 Protocol Modbus RTU J M
3. Ist Enhanced Identification X CANCEL F Enable Variable Nodes Description Volume UO SO TO Type of Data Volume m gt VIF ASCII String Instantaneous Value v Function Field Variables Dimension bit 32 w Length Variable Len o Unit o Modbus Register 236 Modbus Re Scale 238 Delete Items Storage Number 0 Tariff 0 VIFE Not Selected Time Point E Use five Modbus Register YY jo MM 0 HH 0 MM o From BCD to Integer El Convert in Float MODIFY VARIABLE value of Modbus Register that contains the data of the M Bus device It is possible to insert from Modbus Register 1 to 60000 In the field Modbus Re Scale it is necessary to insert the value of Modbus Register that contains the value of measure scale If the scale is not necessary you have to insert the number O in this field It is possible to insert from Modbus Register 1 to 60000 In the field Storage Number if it is necessary it is possible to insert the value of storage counter of that variable With this field the slave can indicate and transmit various stored counter states or historical values in the order in which they occur In the field Tariff if it is necessary it is possible to insert the value of the tariff of that variable The Tariff is used for indicates from w
4. MN67029M 232 485 ENG Revision 2 052 Page 25 of 31 Industrial Electronic Devices Note TA When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67029M 232 xxx or HD67029M 485 xxx device Warning If the Fig 9 appears when you try to do the Update before require assistance try these points Check if the serial COM port selected is the correct one z Check if the serial is connected between the PC and the device Spe Unde Try to repeat the operations for the updating as Ver 1 000 If you are using a dongle try with a native COM port or change the dongle Try with another PC Try to restart the PC PROJECT PROTECTION If you are using the program inside a Virtual Machine try to use in the main Operating System FIRMWARE PROTECTION Figure 9 Protection window A In the case of HD67029M 232 you have to use the software SW67029 www adfweb com download filefold SW67029 zip A In the case of HD67029M 232 40 HD67029M 232 80 HD67029M 232 160 HD67029M 232 250 you have to use the software SW67029 40 80 160 250 www adfweb com download filefold SW67029 40 80 160 250 zip A In the case of HD67029M 485 you have to use the software SW67029 www adfweb com download filefold SW67029 zip 4A In the case of HD67029M 485 40 HD67029M 485 80 HD67029M 485 160 HD67029M 485 250 you have to use the software SW67029 40 80
5. Null Modem Cable form your PC to the Gateway Insert the Boot Jumper For more info see Fig 1 2 3 4 Select the COM port and press the Connect button Turn on the device Follow these steps to update the HD67029 from RS232 1 Turn OFF the Device 2 Insert the Boot Jumper see the manual 3 Select the COM port and press the connect button COM1 iy Connect 4 Turn ON the Device 5 Check the BOOT led It must blink quickly X Cancel Next I gt Check the BOOT Led It must blink quickly For more info see Fig 1 2 3 4 Press the Next button Select which operations you want to do You can select only Firmware only Project or both of them Press the Execute update firmware button to start the upload When all the operations are OK turn off the device Disconnect the Boot jumper Disconnect the RS232 Cable Turn on the device At this point the configuration firmware on the device is correctly update Update Device Options Ti Firmware wt Read Firmware when finish wt Project wt Read Project when finish Execute update firmware oS Figure 8 Update Device windows ADFweb com Srl IT31010 Mareno Treviso INIT Waiting er 2 080 FIRMWARE Waiting PROJECT Waiting INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code
6. Power MW Power GJ h Flow Temperature Return Temperature Temperature Difference External Temperature Cold Warm Temperature Limit F Cold Worm Temperature Limit C Cumul count max power INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices _ per second _ per minute _ per hour _ per day _ per week _ per month _ per year _ per revolution measurement _ increment per input pulse on input channel _ increment per output pulse on output channel _ per liter _ per m43 _ per kg _ per K Kelvin _ per kWh _ per GJ _ per kW _ per K l Kelvin liter _ per V Volt _ per A Ampere _ multiplied by sek _ multiplied by sek V _ multiplied by sek A _ start date time of _ VIF contains uncorrected unit instead of corrected unit _ Accumulation only if positive contributions _ Accumulation of abs value only if negative contributions _ upper lower limit value _ of exceeds of lower upper limit _ Date time of begin end of first last lower upper limit exceed ADFweb com Srl IT31010 Mareno Treviso User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 20 of 31 Duration of limit exceed Duration of first last Date time of first last begin end Multiplicative currection factor Additive correction constant unit of VIF offset Moltiplicative correction factor 10 53 future value next VIFE s an
7. isn t nothing changes If the field SWAP is checked the byte of data of that variable are swapped Example from 0x01020304 to 0x04030201 Inthe field Position insert the number of the variable that you want on Modbus ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices Example 0x68 Start Byte OxBD L Fied OxBD L Field 0x68 Start Byte 0x08 C Field 0x02 A Field 0x72 CI Field 0x71 Identification Number Byte 4of4 0x65 Identification Number Byte 30f4 0x45 4 Identification Number Byte 20f4 0x28 Identification Number Byte 10f4 0x4D Manufacturer Byte 20 Ox6A Manufacturer Byte 1of2 0x81 Version 0x04 Medium Ox3E Access Number 0x00 Signature Byte 2of2 0x00 Signature Byte 1of2 0x04 DIF 0x79 VIF Identification 0x00 Data Byte 40f4 0x00 Data Byte 30f4 0x00 Data Byte 20f4 0x00 Data Byte 10f4 0x04 DIF 0x06 VIF Energy 0x00 Data Byte 40f4 0x00 Data Byte 30f4 0x00 Data Byte 20f4 0x00 Data Byte 10f4 0x44 DIF 0x06 VIF Energy 0x00 Data Byte 40f4 0x00 Data Byte 30f4 0x00 Data Byte 20f4 0x00 Data Byte 10f4 A Other Variables 0x55 Check Sum 0x16 Stop Byte User Manual Document code MN67029M 232 485_ENG Identification Number or Secondary Address putted in the selected register if Identification Numbe
8. of 31 Industrial Electronic Devices Data type F 96 Bye oi 913 pi 911 94 o9 98 98 9 921 290 919 918 gly pile 931 930 9 9 pyr aa 926 925 974 Min 0 59 Hour 0 23 Day 1 31 Month 1 12 Year 0 99 Ti Summer Time 0 Reserved 0 Data type G N E E 915 oi 913 gE 911 94 99 98 Day 1 31 Month 1 12 Year 0 99 For example if you have defined Type of Data Energy J Function Field Instantaneous Value Dimension 32 bit Modbus Register 150 Register 151 declared implicitly because the dimension is 32 bit Modbus Re Scale 152 After the request in Modbus register 150 you read 0x0004 in 151 you read 0x5678 and in register 152 is write 0x0006 The value obtained is 284280 x10 J 744 4 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices UPDATE DEVICE User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 24 of 31 By pressing the Update Device button it is possible to load the created Configuration into the Update Firmware from erial RS232 device and also the Firmware if is necessary In order to load the parameters or update the firmware in the gateway follow these instructions r i 4 ee H HE Turn off the Device Connect the
9. standard slaves 1 5mA consumption connected to M Bus Modbus Communication Port 232 Modbus over RS232 485 Modbus over RS485 and RS232 Enclosure Connectors Type M Modulbox 4M DIN Rail mounting Fixed Screw Terminal Device Family HD67029 Gateway M Bus Master from to Modbus Slave HD67029M 232 20 HD67029M 232 40 HD67029M 232 80 HD67029M 232 160 HD67029M 232 250 HD67029M 485 20 HD67029M 485 40 HD67029M 485 80 HD67029M 485 160 HD67029M 485 250 Gateway M Bus to Modbus on RS232 up to 20 slaves connected to M Bus Gateway M Bus to Modbus on RS232 up to 40 slaves connected to M Bus Gateway M Bus to Modbus on RS232 up to 80 slaves connected to M Bus Gateway M Bus to Modbus on RS232 up to 160 slaves connected to M Bus Gateway M Bus to Modbus on RS232 up to 250 slaves connected to M Bus Gateway M Bus to Modbus on RS485 up to 20 slaves connected to M Bus Gateway M Bus to Modbus on RS485 up to 40 slaves connected to M Bus Gateway M Bus to Modbus on RS485 up to 80 slaves connected to M Bus Gateway M Bus to Modbus on RS485 up to 160 slaves connected to M Bus Gateway M Bus to Modbus on RS485 up to 250 slaves connected to M Bus INFO www adfweb com Phone 39 0438 30 91 31 Order Code Order Code Order Code Order Code Order Code Order Code rae Industrial Electronic Devices ACCESSORIES APW040 APWO080 APW160 APW250 AC34107 AC34114 ADFweb com Srl IT31010 Mareno Treviso User Manual M
10. to insert an address Modbus E Hono GTS Swap Identification Num Type 4 7 that contain the Status of the M Bus device If you don t need to VAR Operating Time days UOSOTO Sead SND ANKE know this put this register at 0 was ne nan 7 ga a x P P Erao E By Position z In the field Identification Number it is possible to insert an VARA Somme tig U 2m0 a ect j z j ihe y VAR Firmware Version UOSOTO a address Modbus that contain the Identification Number of the M Bus VAR Software Version UOSOTO 2 ID 28456571 Hall device You have to read two consecutive registers for knowing the ao eo value If you don t need to know this put this register at 0 If the field Convert BCD in Integer Identification Num is checked the gateway converts the Identification Number that is normally expressed in BCD in a Integer In the field Swap Identification Num it is possible to select the swap mode of the Identification Number If swap isn t necessary you have to select None otherwise see the section Swap Identification page 21 of this document for select the swap mode If the field Send SND_NKE is checked the Gateway send the SND_NKE frame to start the communication In the field Send Reset App Is checked the gateway send the Application Reset command to the slave In the field Variables List it is possible to select which type of variables definition to use I
11. 160 250 www adfweb com download filefold SW67029 40 80 160 250 zip ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 26 of 31 Industrial Electronic Devices CHARACTERISTICS OF THE CABLE RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a NULL MODEM cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232C Cable not exceed 15 meters NULL MODEM CABLING gt gt ii N N m re 3 o in gt CABLE CABLE Side A Side B FEM FEM Figure 10 Null modem cabling M Bus A two wire standard telephone cable JYStY N 2 0 8 mm is used as the transmission medium for the M Bus The maximum distance between a slave and the repeater is 350m this length corresponds to a cable resistance of up 292 This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud and a maximum of 250 slaves The maximum distance can be increased by limiting the Baud rate and using fewer slaves but the bus voltage in the space state must at no point in a segment fall below 12V because of the remote powering of the slaves In the standard configuration the total cable length should not exceed 1000m in order to meet the requirement of a maximum cable capacitance of 180nF Taken f
12. 2 80 or HD67029M 485 80 support up to 80 M Bus devices HD67029M 232 160 or HD67029M 485 160 support up to 160 M Bus devices HD67029M 232 250 or HD67029M 485 250 support up to 250 M Bus devices 44 44 A In the case of HD67029M 232 160 and or HD67029M 485 160 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet back plate To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air A In the case of HD67029M 232 250 and or HD67029M 485 250 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet back plate These units have a fan in the top of the enclosure To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air Take care to not cover the fan It is recommended to put the device into a ventilated cabinet ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 8 of 31 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 15 21V AC and 18 35V DC The consumption depends to the code of the device For more details see the two tables below VAC N VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC Device No Load W VA F
13. 40 HD67029M 232 80 HD67029M 232 160 HD67029M 232 250 Modbus request 15 21 VAC M Bus 18 35 VDC Connector RS232 Ledi Connector Green O OG0000 OV Ground V Positive wire V AC min 15V max 21V V DC min 18V max 35V Jumperi Boot Jumper es Yes Jumper Boot Mode Bs No Jumper Normal Mode Figure 3 Connection scheme for HD67029M 232 xxx Dic i Connector2 Unpolarized INFO Document code MN67029M 232 485_ENG www adfweb com M Bus from to Modbus on RS232 RS485 Revision 2 052 Page 5 of 31 Connector3 Port RS232 D SUB9 Male Isolated Port PINS Shield to Isolated Ground Used for Programmation Port Modbus on RS232 o connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 Or a cable made as showed here Phone 39 0438 30 91 31 Industrial Electronic Devices Order Code HD67029M 485 40 Order Code HD67029M 485 80 Order Code HD67029M 485 160 Order Code HD67029M 485 250 OV Ground V Positive wire V AC min 15V max 21V V DC min 18V max 35V User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 6 of 31 Jumper2 Termination Modbus Line GO Open Ga 220 ohm S Shield to Isolated Ground B Negative wire A Positive wire Connectors3 Port RS232 D SUB9 Male Isolated Por
14. Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 30 of 31 Power Supply for M Bus Master device that supports up to 40 Slaves Power Supply for M Bus Master device that supports up to 80 Slaves Power Supply for M Bus Master device that supports up to 160 Slaves Power Supply for M Bus Master device that supports up to 250 Slaves Null Modem Cable Fem Fem DSub 9 Pin 1 5 m Null Modem Cable Fem Fem DSub 9 Pin 5 m INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 31 of 31 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under
15. Industrial Electronic Devices UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS INDEX CONNECTION SCHEME CHARACTERISTICS POWER SUPPLY SET COMMUNICATION PARAMETERS CONFIGURATION FUNCTION MODES USE OF COMPOSITOR SW67029 NEW PROJECT OPEN PROJECT SET COMMUNICATION M BUS UPDATE DEVICE CHARACTERISTICS OF THE CABLE MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS ADFweb com Srl IT31010 Mareno Treviso Page OUDWOANWNNNNN User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 2 of 31 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is gt Updated gt Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates To obtain the updated documentation for the product that you own note the Document Code Abbreviated written Doc Code on the label on the product and download the updated from our web site www adfweb com download REVISION LIST Revisi
16. Revision 2 052 Page 22 of 31 Aib Industrial Electronic Devices To know the meaning of value read in the Modbus Re Scale field you must follow this table x Value read in Modbus Re Scale Description Range Coding Range Energy ig Wh 0 001 Wh to 10000 Wh Energy 10 J 0 001 kJ to 10000 kJ Volume 10 amp m 0 001 I to 10000 Mass 10 7 kg 0 001 kg to 10000 kg x 0 Seconds x 1 Minutes Cus as x 2 Hours x 3 Days Operating Time coded like On Time Power 10 gt W 0 001 W to 10000 W Power 10 J h 0 001 kJ h to 10000 kJ h Volume Flow io amp m h 0 001 I h to 10000 I h Volume Flow Ext ioe 7 m min 0 0001 l min to 1000 l min Volume Flow Ext 19 m s 0 001 ml s to 10000 ml s Mass Flow 19 kg h 0 001 kg h to 10000 kg h Flow Temperature 10 C 0 001 C to 1 C Return Temperature 10 C 0 001 C to 1 C Temperature Difference 10 K 1 mK to 1000 mK External Temperature 10 oC 0 001 C to 1 C Pressure 10 73 bar 1 mbar to 1000 mbar Averaging Duration coded like On Time Actuality Duration coded like On Time n x 0 Date Data type G Time Faint x 1 Time amp Date Data eine F Unit for H C A dimensionless INFO www adfweb com ADFweb com Srl IT31010 Mareno Treviso Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 23
17. d data of this block are manufacturer specific None Too many DIFE s Storage number not implemented Unit number not implemented Tariff number not implemented Function not implemented Data class not implemented Data size not implemented Too many VIFE s Illegal VIF Group Illegal VIF Exponent VIF DIF mismatch Unimplemented action No data available undefined value Data overflow Data underflow Data error Premature end of record INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 21 of 31 ried Industrial Electronic Devices Swap Identification This field is used for select the Swap mode of Identification Number At the moment there are these possibilities None Type l Examples Identification Number Secondary Address 12345678 Address Register 1000 Convert BCD in Integer Identification Num not checked None 1000 0x1234 1001 0x5678 Type 1 1000 0x5678 1001 0x1234 Identification Number Secondary Address 12345678 Address Register 1000 Convert BCD in Integer Identification Num checked None Type 1 1000 0x00BC 1000 0x614E 1001 0x614E 1001 OxOOBC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG
18. de Figure 1 Connection scheme for HD67029M 232 INFO www adfweb com Phone 39 0438 30 91 31 ADFweb com Srl IT31010 Mareno Treviso i i User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485_ENG Revision 2 052 Page 4 of 31 Industrial Electronic Devices N S Connector3 Port RS232 D SUB9 Male Connector4 Order Code HD67029M 485 Modbus on RS485 Isolated Port S Shield to Isolated Ground B Negative wire A Positive wire Jumper2 ODDOGOOOQOOOODDOOE sed for Termination Modbus Line rere ma Programmation Port Open 18 35 VDC ee Modbus on RS232 PINS Shield to Isolated Ground o connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 D 220 ohm RS485 Or a cable made as showed here Connector RS232 a s Ss Connector OVOQVDOOOS O66 808868 CABLE CABLE Side A Side B V Positive wire AC min 15V max 21V V DC min 18V max 35V Jumperi Boot Jumper Ves Jumper Connector2 M Bus response Boot Mode Unpolarized E No Jumper M Bus Normal Mode Figure 2 Connection scheme for HD67029M 485 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices Order Code Order Code Order Code Order Code ADFweb com Srl IT31010 Mareno Treviso User Manual HD67029M 232
19. ew Project button creates the folder which contains the entire device configuration A device configuration can also be imported or exported To clone the configurations of a Programmable M Bus to Modbus Gateway in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the button Open Project When a new project is created or an existent project is open it will be possible to access the various sections of the software e Set Communication M Bus e Update Device ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 11 of 31 Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of two buses Modbus and M Bus By Pressing the Set Communication button from the main window for SW67029 Fig 5 the window Set Communication appears Fig 6 The window is divided in two sections one for the Modbus line Serial and the other for the M Bus The means of the fields for Serial are If the device is HD67029M 232 the field RS232 must be checked otherwise if is the
20. f measure In the field VIF ASCII String insert the string of VIF It is possible to use this field only if the Type of Data is VIF is in ASCII In the field Function Field it is necessary to select the type of data The field Dimension is used to select the dimension of the variable 8 16 24 32 32 real 48 64 bit Variable Length In the field Length Variable Len insert the length of the data in the case of the dimension is Variable Length In the field Unit if it is necessary it is possible to select the unit of that variable The Unit is used for indicates from which device the data come In the field Modbus Register it is necessary to insert the VAR Time Point time date UOSOTO VAR Volume m3 U1SOTO VAR Volume m3 U2SOTO VAR Firmware Version UOSOTO VAR Software Version UOSOTO ID 28456571 Hall ID 3 First Floor VAR Energy UO SO TO VAR Energy UO S1 TO VAR Volume UO S1 TO Volume UO S2 TO Time Point UO S8 TO Energy U0 S8 TO Energy U0 S9 TO Volume U0 S9 TO Volume UO S10 TO Volume UO SO TO Volume Flow UO SO TO Power UO SO TO Flow Temperature UO SO TO Return Temperature UO SO TO Time Point UO SO TO Time Point UO S17 TO Time Point UO S32 TO Energy U0 S32 TO Min Energy UO S32 TO Ist Time Point UO S33 TO Energy U0 S33 TO Min Energy UO S33 TO Ist Time Point UO S34 TO Energy U0 S34 TO Min Energy U0 S34 TO
21. f is selected By Type it is necessary to fill all fields in the section Variables with the correct values otherwise if By Position is selected you can insert the progressive number of the variable that you need page 15 16 for more information After that pressing the ADD NODE button a new node appears in the left side of the window In order to modify a created node it is necessary to select the desired node change the wrong items and then press the MODIFY NODE button Figure 7 M Bus Network window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 13 of 31 Industrial Electronic Devices SECTION VARIABLES By TYPE Selecting the desired node it is possible to add a variable In order to create a new variable it is necessary to fill these items VAR Operating Time days UOSOTO To use the created variable the field Enable Variable must be checked If you have created a variable but for the moment it is unused it is possible to uncheck the field Enable Variable without delete it In the field Description it is possible to write a description of the variable it isn t a necessary information it helps the readability of the tree of network The field Type of Data is used to select the unit o
22. hich device the data come In the field VIFE it is possible to select a sub type of Type of Data ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 14 of 31 Industrial Electronic Devices If the field Use Five Modbus Register and the Type of Data is Time Point it is possible to read the information of Year Month Day Hour Minutes on five consecutive Modbus registers without decoding the data if not selected the values are the same of the reply of the slave device so coded with a determinate structure You have to insert the first Modbus Register If the field From BCD to Integer is checked the Gateway converts the BCD value of variable in Integer format This happens only if the variable is in BCD format if it isn t nothing changes If the field Convert in Float is checked the Gateway converts the data into Float type Every variable occupies two consecutive Modbus Registers and the first one is the one defined in Modbus Register In this case the float value is multiplied by the Modbus Re Scale automatically Having completed this fields to add the variable the button ADD VARIABLE must be pressed In order to modify a created variable it is necessary to select the desired variable change the wrong items and then p
23. hout BOOT jumper with this setting the HD67029M 232 or HD67029M 485 is able to function as an adapter M Bus to Modbus on RS232 RS485 BOOT MODE with BOOT jumper the boot mode is activated when the HD67029M 232 or HD67029M 485 is turned on Eventual program updates are available on the site www adfweb com When the RUN Led blinks at frequency of about 1 second the device functions in Normal Mode otherwise if the run LED blinks more quickly the device is in Boot Mode ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 10 of 31 Industrial Electronic Devices USE OF COMPOSITOR SW67029 or SW67029_40_80_160_250 To configure the Gateway use the available software that runs with Windows called SW67029 or SW67029_40_80_160_250 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows MS 2000 XP Vista Seven mpositor SW67029 M Bu 4 New project 4 Open project FF Set Communication When launching the SW67029 the right window appears Fig 5 M Bus ET Update Device www ADFweb com Figure 5 Main window for SW67029 and SW67029_40_80_160_250 NEW PROJECT OPEN PROJECT The N
24. ible choices for the fields used to create a variable Type of Data _Energy Wh _Energy J _ Volume m _ Mass Kg _On Time _ Operating Time _ Power W _ Power J h _ Volume Flow m h _ Volume Flow Ext m min _Volume Flow Ext m s _Mass Flow Kg h _ Flow Temperature C Return Temperature C _ Temperature Difference K _ External Temperature C _ Pressure bar _ Averaging Duration _Actuality Duration _ Type of data in VIFE _ Time Point _VIF is in ASCII _ Unit for H C A _ Fabrication No _ Enhaced Identification _ Bus Address ADFweb com Srl IT31010 Mareno Treviso User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Function Field _ Instantaneous Value _ Minimum Value Maximum Value _ Value During Error State Dimension bit _32 real _48 _ 64 _ Variable Length INFO www adfweb com Revision 2 052 Page 18 of 31 Phone 39 0438 30 91 31 Industrial Electronic Devices VIFE __ Not Selected _ Credit of the nominal local legal currency units _ Debit of the nominal local legal currency units _ Access Number transmission count _ Medium as in fixed header _ Manufacturer as in fixed header _ Parameter set identification _ Model Version _ Hardware Version _ Firmware Version _ Software Version _ Customer Location __ Customer _ Access Code User _ Access Code Operator _ Acces
25. odbus ASCII JBUS 5 Binary 5 ASCII M Bus Baudrate 38400 x Parity ODD x M Bus Poll on request l Cyclic request J OK Figure 6 Set Communication window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 12 of 31 Industrial Electronic Devices M BUS By Pressing the M Bus button from the main window for SW67029 Fig 5 the window M Bus Network appears Fig 7 SECTION NODES In the section Nodes it is possible to create the nodes of M Bus line In order to create a new node it is necessary to select which M Bus Network address use selecting Primary ID or Secondary ID to makes NID 10534069 Integral Description integral n n VAR Fabrication Number Z Primary ID Secondary ID the requests and then insert the Primary Address from 1 to 250 Nis clog fae Cee E or the Secondary Address from 0 to 99999999 of M Bus device in VAR Volume m3 UOSOTO E iode Sinia z the field ID Node M Bus In the field Description it is possible a ara a CES a redran i to write a short description of the node Vag Betum Tempe 0 C 5 El Convert BCD in Integer Identification Num Temperature Difference ee In the field Node State it is possible
26. on Date Author Chapter Description 2 020 19 07 2010 FI All Software changed v1 900 v1 200 2 030 22 09 2010 FI All Software changed v2 200 v2 200 2 040 05 11 2010 FI All Software changed v2 203 2 050 02 12 2010 FI All Software changed v2 300 2 051 19 01 2011 FI All Revision 2 052 01 02 2012 FI All Revision WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus from to Modbus on RS232 RS485 AL Document code MN67029M 232 485_ ENG Revision 2 052 Page 3 of 31 Industrial Electronic Devices CONNECTION SCHEME S OCOOCOCOCOCOCOOQAOOOOOOA sed for Programmation Port 15 21 VAC M Bus Modbus on RS232 18 35 VDC Connector PINS Shield to Isolated Ground o connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 Or a cable made as showed here RS232 amp Connector COOCOO OCOOOGO CABLE Side B FEM OV Ground V Positive wire V AC min 15V max 21V DC min 18V max 35V Yes Jumper M Bus response Boot Mode Change state when cao receive a correct Ne Jumper Modbus request M Bus Normal Mo
27. r is checked Fixed Data Header First Variable O Second Variable Third Variable G ADFweb com Srl IT31010 Mareno Treviso Node State is checked Status of the meter putted in the selected register if To be use in the Position field INFO www adfweb com M Bus from to Modbus on RS232 RS485 Revision 2 052 Page 16 of 31 Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 17 of 31 Industrial Electronic Devices SECTION DELETE ITEMS If it is necessary to delete a node or a variable you have to select iM iuit the node or the variable and then press the DELETE ITEM M Bus network ID 10534069 Integral button VAR Fabrication Number VAR Energy Wh UOSOTO VAR Volume m3 UOSOTO VAR Volume Flow m3 h UOSOTO VAR Flow Temperaure C UOSOTO VAR Return Temperature C VAR Temperature Difference k UOSOTO VAR Operating Time hours UOSOTO VAR Operating Time days UOSOTO VAR Time Point time date UOSOTO VAR Volume m3 U1SOTO VAR Volume m3 U2SOTO VAR Firmware Version UOSOTO VAR Software Version UOSOTO ID 28456571 Hall ID 3 First Floor DELETE ITEM Nodes Variables ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices Poss
28. ress the MODIFY VARIABLE button ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices SECTION VARIABLES BY POSITION Selecting the desired node it is possible to add a variable In order to create a new variable it is necessary to fill these items M Bus Network a wicncide vatlatie ID 10534069 5 Integral g To use the created variable the field Enable Variable ee 2 a uosoTo 3 Energy Wh UOSOTO imension bi must be checked If you have created a variable but for the Volume m3 UOSOTO EE moment it is unused it is possible to uncheck the field aA enni ie EA Ea B Modbus Register 02 Enable Variable without delete it Return Temperature C UOSOTO Modbus Re Scale o n P g Temperature Difference k UOSOTO In the field Description it is possible to write a Operating Time hours UOSOTO a Time Point 7 r P TEE 1 k Operating Time days UOSOTO g El use five Modbus Register description of the variable it isn t a necessary information Time Point time date UOSOTO Blag a it helps the readability of the tree of network ge me a Slm p mm 0 Volume m a The field Dimension is used to select the dimension of Firmware Version U0SOTO E From BCD to Integer a Software Version UOSOTO the variable 8 16 24 32 32 real 48 64 bit Variable aesa ae El Convert in Float Length ID 3 First Floor Po
29. rom M Bus specifics ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 27 of 31 Industrial Electronic Devices MECHANICAL DIMENSIONS z aita CODD OOOOOVOBO DDIOOAO C8 GDOOOGe GQOQQDVVOOO cS ef E Z S X Be m E ae 106 mm 60 mm 106 mm 60 mm 4 17 inch 2 36 inch 4 17 inch 2 36 inch Housing PVC Housing PVC Weight 200g Approx Weight 200g Approx Figure 11 Mechanical dimensions scheme for HD67029M 232 Figure 12 Mechanical dimensions scheme for HD67029M 232 40 HD67029M 485 80 GODOO00090 GOBODO90OO C8 OGO0088 GOGDDOOOO eS 4 E lt E T a X aS COOQVOOOGS 6008008008 COOOSLCOC CO 066380008008 Ee a 106 mm r 60 mm 106 mm 60 mm 4 17 inch 2 36 inch 4 17 inch 2 36 inch Housing PVC Housing PVC Weight 200g Approx Weight 200g Approx Figure 13 Mechanical dimensions scheme for HD67029M 485 Figure 14 Mechanical dimensions scheme for HD67029M 485 40 HD67029M 485 80 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices 95 mm 3 74 inch 106 mm 4 17 inch E n i 63 mm gt 2 56 inch Housing PVC Weight 200g Approx Figure 15 Mechanical dimensions scheme for HD67029M 232 160 95 mm 3 74 inch B 106 mm 63 mm 4 17 inch
30. s Code System Operator _ Access Code Developer _ Password _ Error flags binary _ Error mask _ Digital Output binary _ Digital Input binary _ Baudrate Baud _ response delay time bittimes _ Retry _ First storage for cyclic storage _ Last storage for cyclic storage _ Size of storage block _ Storage interval sec s day s __ Storage interval month s __ Storage interval year s _ Duration since last readout sec s day s _ Start date time of tariff _ Duration of tariff nn 01 11 min to day _ Period of tariff sec s to day s ADFweb com Srl IT31010 Mareno Treviso l _ l _ l _ _ l _ _ _ l l _ _ _ Energy GJ _ l _ l l _ l _ _ l _ l User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485_ENG Revision 2 052 Page 19 of 31 Period of tariff months s Period of tariff year s dimensionless no VIF Volts Ampere Reset counter Comulation counter Control signal Day of week Week number Time point of day change State of parameter activation Special supplier information Duration since last comulation hour s year s Operation time battery hour s year s Date and time of battery change Energy MWh Volume Mass Volume 0 1 feet 3 Volume 0 1 american gallon Volume 1 american gallon Volume flow 0 001 american gallon min Volume flow 1 american gallon min Volume flow 1 american gallon h
31. sition 2 In the field Length Variable Len insert the length of e the data in the case of the dimension is Variable Length In the field Modbus Register it is necessary to insert the value of Modbus Register that contains the data of the M Bus device It is possible to insert from Modbus Register DI to 60000 Inthe field Modbus Re Scale it is necessary to insert the value of Modbus Register that contains the value of measure scale If the scale is not necessary you have to insert the number O in this field It is possible to insert from Modbus Register 1 to 60000 User Manual Document code MN67029M 232 485 ENG X cancet M Bus from to Modbus on RS232 RS485 Revision 2 052 Page 15 of 31 Ifthe field Use Five Modbus Register and the Type of Data is Time Point it is possible to read the information of Year Month Day Hour Minutes on five consecutive Modbus registers without decoding the data if not selected the values are the same of the reply of the slave device so coded with a determinate structure page 22 for more information You have to insert the first Modbus Register If the field From BCD to Integer is checked the Gateway converts the BCD value of variable in Integer format This happens only if the variable is in BCD format if it
32. t PIN2 RX T PIN3 TX PIN5 Shield to Isolated Ground Used for Programmation Port Modbus on RS232 M Bus Connector 15 21 VAC 18 35 VDC To connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 RS485 deeso Or a cable made as showed here RS232 Led1 EIS Connector OOOOQOQG OO O8O88O08 CABLE Side A FEM CABLE Side B FEM Connector2 Unpolarized M B Yes Jumper sk Boot Mode No Jumper Normal Mode Figure 4 Connection scheme for HD67029M 485 xxx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 7 of 31 Industrial Electronic Devices CHARACTERISTICS The HD67029M 232 xxx HD67029M 485 xxx is Gateway M Bus to Modbus Slave line It allows the following characteristics Electrical isolation between RS232C RS485 and M Bus Baud Rate and Parity changeable with software Mountable on Rail DIN Power Supply 15 21V AC or 18 35V DC Temperature range 30 C to 70 C 444 At the Gateway can be connected up to 250 standard M Bus devices This number depends of the code expressed by the xxx number HD67029M 232 or HD67029M 485 support up to 20 M Bus devices HD67029M 232 40 or HD67029M 485 40 support up to 40 M Bus devices HD67029M 23
33. ull Load W VA HD67029M 232 HD67029M 485 4 HD67029M 232 40 HD67029M 485 40 5 HD67029M 232 80 HD67029M 485 80 3 5 HD67029M 232 160 HD67029M 485 160 14 HD67029M 232 250 HD67029M 485 250 30 This value is with all the Slave M Bus devices of the code 20 40 80 160 250 connected to the line Caution Not reverse the polarity power HD67029M 232 xxx HD67029M 485 xxx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual M Bus from to Modbus on RS232 RS485 Document code MN67029M 232 485 ENG Revision 2 052 Page 9 of 31 Industrial Electronic Devices SET COMMUNICATION PARAMETERS Configurable Parameters Baud Rate of RS232 RS485 from 1200 to 115200 bps and of M Bus from 300 to 38400 bps Parity of RS232 RS485 and M Bus with None Odd Even Fixed Parameters 1 Bit Start 8 Bit Data 1 Bit Stop The Baud Rate and the Parity of RS232 RS485 and M Bus are configurable with the software CONFIGURATION You need Compositor SW67029 software on your PC in order to perform the following Define the parameter of Modbus line Define the parameter of M Bus line Define which Modbus register contain the M Bus information Update the device 744 4 FUNCTION MODES For the device HD67029M 232 and HD6702M 485 it is possible to update the microprocessor program Therefore there are two functions to select from the boot jumper NORMAL MODE factory setting wit
34. warranty you will receive a repair estimate PRODUCTS AND RELATED DOCUMENTS Part Description URL HD67120 Converter Ethernet to RS232 RS485 www adfweb com product HD67120 HD67119 Converter USB 2 0 to RS485 Isolated www adfweb com product HD67119 HD67507 Gateway Modbus TCP Server to RTU Master www adfweb com product HD67507 HD67510 Gateway Modbus TCP Client to RTU Slave www adfweb com product HD67510 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31