Home

CCTV TesterPro

image

Contents

1. adapter 24 UTP cable port Please use together with UTP LAN cable tester 25 8 l icati l 2 2 2 29 RS232 interface RS232 Hole for the safety cord communication for the PTZ RS485 422 Interface RS485 RS422 communication for the PTZ Page 9 CCTV testerPRO Users Manual 3 2 PTZ Controller Display the input video images Pan tilt the P T unit and zoom in out the image Setup the controlling parameters like protocol communication port baud rate PTZ ID pan tilt speed set and call preset position The following connections should be confirmed before use a The Video In interface of the CCTV testerPRO and the output interface of camera b Data A of the CCTV testerPRO and A of the PTZ camera or controlling device data B of the instrument and B of the PTZ camera or controlling device Note Don t connect communications interface with a circuit the voltage higher than 6V Te a S Xp BS iF h LaF cy Up a y PTZ controller a Press SET key to enter the sub menu of PTZ controller Port 5 BA Baud b Press the or key to select the parameter Address Pan speed TiltSpeed setl P3 Get PS which we want to change the value c Press ENTER key to save the change or press RETURN key to give up the change d Press SET key to exit the sub menu e Press POWER key to full screen the image Page 14 Contrast Saturation Colorbar generator Dala monitor Baud 00 40
2. 0 63 F TiltSpeed Set the tilt speed of PTZ camera 0 63 G Set PS Setup preset position 0 128 a P T Z the camera to desired position b Press SET key to enter PTZ controller submenu c Move the yellow cursor to Set PS and then press lt 1 or A key to select the preset position number d Press ENTER key to complete preset position setting or preset RETURN key to give up preset position setting Tips Press gt or lt 1 key to accelerate the value changing H Go PS Call the preset position 0 128 The PTZ camera will go to the desired preset position a Move the yellow cursor to Go PS and then press lt 1 or gt key to select the preset position number b Press ENTER key to complete preset position calling or preset RETURN key to give up preset position calling Tips Press gt or a key to accelerate the value changing The way of calling the OSD menu and preset of the PTZ camera may vary with control systems from different manufacturers Please read the operation manual of control system manufacturer for details The way of calling OSD provided for reference is calling preset 64 a Move the yellow cursor to PTZ controller to enter PTZ controller mode b Press SET key to enter PTZ controller sub menu Press A or v key to move the yellow cursor to Go PS Page 15 Page 8 ENTER OPEN RETURN CLOSE FAR TELE WIDE CCTV testerPRO User s Manual Sub menu
3. Shows and sets the values of functions Long pressing it more than 2 seconds to turn on off the tester short pressing to turn on off the PTZ controller menu displaying Menu key it pops up the main menu constant press it or press the L or LY key can shift between functions Setup key press it or press left or right key to enter sub menu to set the parameters of functions Upward Select the item which will be set or add the value of the parameter Tilt the PTZ upward Leftward Enter the sub menu or select the parameter whose value will be changed Reduce the value of the parameter Pan the PTZ left Rightward Enter the sub menu or select the parameter whose value will be changed Add the value of the parameter Pan the PTZ right Downward Select the item which will be set or reduce the value of the parameter Tilt the PTZ downward Confirm Open Confirm the setting of parameters open the aperture Return Close Return or cancel while setting parameters of the menu close the aperture Near focus Focus the image nearby Far focus Focus the image faraway TELE zoom in the image WIDE zoom out the image 2 4 2 23 Side view Left Side D v our a Top View CCTV testerPRO User s Manual CABLE TEST ESET FE GE Ait Right Side 2 Reset the default settings of parameters External power supply DC 5V It is highly recommended to use the equipped power
4. 1 to 256 When the ID is searched the PTZ camera will pan right At this time please press any key to stop searching Page 20 CCTV testerPRO User s Manual CCTV testerPRO User s Manual a Connect the RS485 or RS232 interface of controlling system with the RS485 or RS232 1 Safety Information interface of the CCTV testerPRO In case of RS485 A to A B to B b Press SET key and then press A or LY key to select communication port according to Noti otice the system connection Press SET key to save the change E l i l l 5 m The tester is intended to use in compliance with the local rules of the electrical d Press or L key to select the baud rate according to the baud rate of controlling usage and avoid to apply at the places which are inapplicable for the use of system and then press SET key to save the change and capture command data from electrics such as hospital gas station etc controlling system e Press RETURN Key doclear the corgen To prevent the functional decline or failure the product should not be sprinkled or damped 3 8 Device setting The exposed part of the tester should not be touched by the dust and liquid Set the parameters of the CCTV testerPRO During transportation and use it is highly recommended to avoid the violent collision and vibration of the tester lest damaging components and causing failure Don t leave the tester alone while charging and recharging If the battery is found severely ho
5. 2 3 4 5 6 7 8 9 O oOo N AU A UU N e OSD menu of dome Call the preset point 064 MAIN MENU Display configuration Set camera parameters Set PTZ controlling Set privacy mask Set auto running functions PAL NTSC Switch Restore the default settings Reset the dome Exit the main menu Operate auto running functions by calling preset position effective for some brands of PTZ camera Call preset 33 Open Auto flip function Call preset 34 Reset zero point of PTZ camera Call preset 64 Enter the main menu of the PTZ camera Call preset 95 Enter the main menu of the PTZ camera or stop the PATTERN recording Call preset 96 Run pattern 1 Call preset 97 Run preset tour 1 Call preset 98 Run frame Scan Call preset 99 Run Auto scan Go PS 4 098 Go PS ee 099 Page 16 Run Frame scanning Call the preset point 098 Run Auto scanning Call the preset point 099 CCTV testerPRO User s Manual A Protocol Select the protocol according to the protocol of the PTZ camera Up to 21 popular protocols are available like elco P Pelco D Samsung Yaan LiLin CSR600 etc B Port Select the communication port for the PTZ camera controlling RS232 422 485 C Baud Select the baudrate according to baudrate of the PTZ camera 150 300 19200bps D Address Set the ID according the ID of PTZ camera 0 254 E Pan Speed Set the pan speed of PTZ camera
6. 4 CCTV testerPRO User s Manual 2 Introduction The CCTV testerPRO is developed for the On Site installation and maintenance of video monitoring system It can be used for displaying video controlling PTZ generating images capturing data of RS485 and testing LAN cable etc Its functions easy operation and portability makes it simple for the CCTV technician to install and maintain CCTV system improving work efficiency and get the labor cost down 2 1 Features m 2 8 TFT LCD 960 H gt x240 V resolution a PTZ control Pan tilts the P T unit zooms in out the lens adjusts the focus aperture and sets and calls the preset position m Video displaying Automatically adapts and displays the video format of NTSC PAL LCD Brightness Contrast Color Saturation are adjustable m Video Level testing video signals measured in IRE or mV m Video Generating The PAL NTSC multi system colorbar video generator seven system switchable transmit receive seven system colorful imagines m Data analyst Captures and analyzes RS485 controlling data to help the technician to find out the problem m Cable testing It is powerful in testing LAN cable measuring the connecting status displaying the sequence of connection and the NO of the LAN cable E Miulti interface and Multi baudrate Support RS232 RS485 and RS422 interface baud rate ranging from 150 600 to 19200bps E Multi protocol Supports more than twenty PTZ protocols For example
7. 4 bo a0 A Am A P W UU A Ug a7 La ali F afa Keypad tone Nel saved Enter to apply CCTV testerPRO User s Manual 2 Video setting Adjust the LCD brightness Contrast Color saturation Video Format displaying and Video level testing 3 Colorbar generator Output or receive seven different forms of video color bar to tester monitor cable or other equipment 4 Cable tester Test LAN cable or telephone cable The connecting condition and the sequence of wires will be displayed as well as the serial number of the cable tester kit 5 Data Monitor Captures the protocol from the controlling system and display command data It is helpful to debug and maintain RS485 communication 6 Device setting Set the parameters of the CCTV testerPRO Auto poweroff Keypad tone Language Brightness Page 13 CCTV testerPRO User s Manual 2 5 Installing the Battery The tester has built in lithium ion polymer rechargeable battery The battery cable inside battery cabin should be disconnected for safety during transportation gt Prior to the use of the instrument the battery cables inside the battery cabin should be well connected and the color of cables should be at the same side POWER Usually it need not to disconnect the cable at the normal use pressing rom key continuously can power on or off the tester y At the first time of use the batteries should be completely exhaust
8. CCTV testerPRO User s Manual KO tecih B Qtech Electronics Co Ltd www b qtech com Email sales b qtech com bqshelly gmail com Products certification USER S MANUAL C Fe CCTV TesterPro Stest 890 Ms Shelly Yoe GM MSN bqshelly hotmail com Skype bqshelly Tel 0086 755 25852163 0086 15994792003 Page 23 Ver STP28V1 3 2009 5 CCTV testerPRO User s Manual Page 1 CCTV testerPRO User s Manual 4 Specification MODEL Video Test CCTV Security TesterPRO Signal mode NTSC PAL Auto adapt Display 2 8 inch digital TFT LCD 960 x 240 resolution LCD adjustment Brightness Contrast Saturation adjustable Video IN OUT 1 channel BNC Input amp 1 channel Output Video Output Mode 1 0 Vp p Video Level test Video signals measured in IRE or mV PTZ controller Communication RS232 RS422 simplex and RS485 Compatible with more than 20 protocols such as PELCO D P Samsung PTZ Protocol Rae Panasonic Lilin Yaan etc Baud Rate 150 300 600 1200 2400 4800 9600 19200bps Video Signal Generation Output channel colorbar video signal for testing monitor or video Color bar generation bl cable UTP CABLE TEST Test UTP cable connection status and display in the screen Read UTP cable test the number of the test box RS485 data analyst Data Monitor POWER Power Adapter DC5V 2A Captures and analyzes the command data from controlling device Battery Built in 3 7V Lithium polymer bat
9. PELCO P PELCO D SAMSUNG etc m PTZ address scanning search up the ID of PTZ camera m Lithium Ion Polymer Battery 3 7V DC2000mAh The device employs advanced power control and protection circuit The device is high power efficient energy saving and environmental protection It can last 11 hours for normal use after charging for 4 hours Page 5 CCTV testerPRO User s Manual a Press the L2 J key to select the parameter which we want to change the value b Press the S key to change the value c Press ENTER key to save the change or press RETURN key to give up the change 3 6 Cable Tester Test LAN cable or telephone cable Connect LAN cable or telephone cable with the CCTV testerPRO and cable tester And then the connecting status cable type and the sequence of wires will be displayed as well as the serial number of the cable tester kit Cable Crossed atharnat Straight through Line Cross Line 3 7 Data monitor Capture the command data from RS485 controlling system Page 18 CCTV testerPRO User s Manual CCTV testerPRO User s Manual 3 4 Video Setting 2 2 CCTV testerPRO Kits User can customize the brightness contrast and saturation of the LCD according to the using environment the CCTV tester auto display the format PAL NTSC of video input and analysis Professional design light and portability video display and data control are deliberately the input video signal level L_ Vid
10. d be kept well in case of reference m Keep the S N label for after sale service within warranty period Product without S N label will be charged for repair service m If there is any question or problem while using the CCTV testerPRO or damages occurred on the product please contact our technical Department Page 2 CCTV testerPRO User s Manual Table of Content T Safety INFORM AMON eA ee iR 3 2 UME POOUC UO Meese oseec eee csee a 4 21 FEAIUTGS eseeaccsecanestanscede ssactesstnsseeenasnes aeesnsesceesentneed npescecssnneseeteeeesneee 4 22 DOV TesierP RO KIIS esses serasacesacanarerrnr Aee ae 5 2 9 FOM Pangh serereoni A case 6 2A olde VIC Wassssan ste pensar e eaa 8 2 9 WNSEANING WME BANOT y siani 9 3 OPET ALI om en eeke seae sete esas nec ae eedecee iets er eeacb bate seeder aes eaors 11 Bol IPOWG ONOI s ren 11 32 MENU amp PUNCIIONS lt 2aeessssitanedeessna a 11 S23 PTZ Conlon rresia 13 3 4 VIGCO SENO cessssctsncsstesesesesesecesecceeiseheenessseeeessaeeeesseeescseceeesedesesedeeese 16 GO COlONDAr QONCIAIOl Hress eee sass a eaenene Soreness eae epee ioe saaeees 16 90 Gable TeSielecssessss sence secs eee eas eeee Sees eE ea 17 3 0 Dala MONOT gt nahea an 17 99 DEVICE SCMING sessceseeenesetitetesssreaecere e eE 18 39 Address SCdl Cliessess8cese eroten keee eea 19 A SPECIHCA ONS 74sata eiee 21 Page 3 CCTV testerPRO Users Manual 3 9 PTZ address scanning Search up the ID of PTZ camera Note Please is
11. ed and then recharged for 4 or 5 hours yy The Charge Indicator lights red when charging the battery The charge indicator turns off automatically when the charging is completed A Notice When the Charge Indicator turns off the battery is approximately 90 charged The charging time can be extended for about 1 hour and the charging time within 8 hours will not damage the battery A The tester can work as usual while it is being charged however But the charging time will be extended Press the RESET key at the right of the instrument to restore the default settings when the instrument works abnormally Unlock the battery cover by pushing horizontally as the direction illustrated Page 10 CCTV testerPRO User s Manual Warning Connect the terminal of the battery with the direction illustrated Please take care of the polarity of terminal The wires of the same color should be both at the one side Connect battery leads before use Lock the batteries by pressing as the direction illustrated Page 11 CCTV testerPRO User s Manual 3 Operation 3 1 Power on Continuously press at least 2 seconds to power on off the CCTV testerPRO When the CCTV testerPRO is powered on press MODE key the main menu will pop up PIZ controler Colorbar generator Cable tester Data monitor Device setting NO video input Menu amp Functions Press MODE key continuously or press the J key to select the functio
12. eo sening anna integrated which makes the instrument so simple practicable easy for use that the training is almost unnecessary for an operator to be skillful a Press the A or Lv key to select the parameter which we want to change the value b Press the K or e key to change the value Press ENTER key to save the change RETUR key to gi the ch a ae a a 3 LAN Cable Tester 5 BNC Cable c The Video Format and Video Level will be displayed in the lower portion of the screen If 6 Safety cord there is no video signal at the Video IN port of the CCTV TesterPRO the type of NTSC or PAL and Video Level will not be displayed Depending on the type of camera connected to the CCTV testerPRO the Video Format will automatically change between NTSC and PAL and the Video Level will automatically change l l 7 RS485 data cable between IRE Institute of Radio Engineers and mV NTSC signals measured in IRE units PAL 2 Power Supply 5V 2A Lithium Ion Polymer Battery 8 Instruction Manual signals measured in mV The Video Level should be within the indicated range Levels that are too low will result in a dim picture with reduced dynamic range A Video Level that is too high will result in washed out pictures with decreased The CCTV testerPRO will display Normal when video levels are 1000mV 20 Exceed or Weak will be displayed when video level out of 1000mV 20 3 5 Colorbar gene
13. n PTZ controller Video settings Colorbar generator LAN cable tester Data monitors Device setting and enter corresponding function setting sub menu Press SET key to set the parameters in function sub menu Note When the CCTV testerPRO is powered on it will return to the function which is being operated before it is turned off 1 PTZ controller Display the input video images Pan tilt the P T unit and zoom in out the image Setup the controlling parameters like protocol communication port baud rate PTZ ID pan tilt speed set and call preset position Baud Address 1 Pan Speed 40 Tilt Speed 40 set PS B Go PS Page 12
14. olate the PTZ camera with other PTZ cameras before searching up Otherwise all the PTZ cameras in the same system will pan at the same time Press keys to Device setting menu Jovica setting M ENTER Press Spen key to confirm after change Address search to on which add address scan sub menu Press to switch the sub menu as illustrated Note The system returns to OFF after shutdown and the i otor Polea P scan sub menu closes automatically Set ON again for next 26 UZEE 4800 use Address 1 Press ser key to set protocol communication port communication rate make them same as the PTZ camera Press or an key the address values is constantly on the rise or decrease NEAR The tester will search up the ID quickly and continuously from 1 to 256 When the ID is searched the PTZ camera will pan right At this time please press any key to stop searching up FAR The tester will search up the ID quickly and continuously from 256 to 1 When the ID is searched the PTZ camera will pan left At this time please press any key to stop searching up WIDE The tester will search up the ID step by step from 1 to 256 When the ID is searched the PTZ camera will stop panning FAR The tester will search up the ID step by step from 256 to 1 When the ID is searched the PTZ camera will stop panning Press button the tester will search up the ID quickly and continuously from
15. rator Output video at any mode Output or receive seven different forms of video color bar to test monitor video cable or other equipment Page 17 Page 6 2 3 15 CCTV testerPRO User s Manual Front Panel 13 12 3 11 14 h 1 Tr lt A gt F CCTV TesterPro tda PIZ control ler ag Pe tor 5 Video setting ColorBar generator Cable tester Data moni ter Device setting 1 l 6 MODE SET POWER iT 8 10 ENTER RETURN oren cose 1 d6 FAR NEAR 17 18 WIDE TELE 19 20 CCTV Security Tester Pro The power indicator it lights green while the tester is powered on The data reception indicator it lights red while the data is being received The data transmission indicator it lights red while the data is being transmitted The charge indicator it lights red while the battery is being charged As the charging is complete the indicator turns off automatically The display Icon of battery electricity it displays the electric quantity Main menu it shows main functions of CCTV testerPRO Page 7 CCTV testerPRO User s Manual C Press lt or gt key to select the preset number 64 and then press ENTER key to call OSD menu of the PTZ controller Go PS 4 064 OSD Menu of Dome For reference only MAIN MENU DISPLAY SETUP CAMERA SETUP CONTROL SETUP CAMERA MASK SET PROGRAM PAL CAMERA CAM DEFAULT SET DOME RESET EXIT 1
16. t the tester should be powered off from the electric source at once The test should not be charged over 8 hours Don t use the tester where the humidity is high Once the tester is damp power Auto poweroff Setting the time of auto shut down Disable 5 10 60 off immediately and move away other cables connected The tester should not be use in the environment with the flammable gas Disable Disable the Auto poweroff function 5 means the CCTV will power off Do not disassembly the instrument since no component inside can be repaired after 5 minutes when there is no any operation by the user If the disassembly is necessary indeed please contact with the Keypad tone Open or close the beep of pressing keypad technician of our company Language Select language of OSD menu The instrument should not be used under the environment with strong Brightness Setting the brightness of OSD menu and background 0 7 o electromagnetic interference Don t touch the tester with wet hands or waterish things a Press A or v key to move the parameter we want to change b Press RKI or gt to change the value c Press ENTER to save the change or press RETURN key to give up the change Don t use the detergent to clean and the dry cloth is suggested to use If the dirt is not easy to remove the soft cloth with water or neutral detergent can be used but the cloth should be tweaked sufficiently Page 19 Page
17. tery 2000mAh Rechargeable After charging 3 4 hour working time lasts 11 hours Low Consumption Energy saving technology General Working 10 C 50 C Temperature 30 90 166mmx95mmx48mm 293g Working Humidity Dimension Weight The data above is only for reference and any change of them will not be informed in advance For more detailed technical inquiries please feel free to call the Technical Department of our company Page 22 CCTV testerPRO User s Manual up Press ree manual single step decreasing button the tester will search up the ID step by step from 256 to 1 When the ID is searched the PTZ camera will stop panning Press button the tester will search up the ID quickly and continuously from 256 to 1 When the ID is searched the PTZ camera will pan left At this time please press any key to stop searching up Press manual single step incremental button the tester will search up the ID step by step from 1 to 256 When the ID is searched the PTZ camera will stop panning Press the direction control button to adjust Speed Dome Camera press button to quit from the address scanning function menu Page 21 CCTV testerPRO User s Manual m Thank you for purchasing the CCTV security tester Please read the manual before using the CCTV testerPRO and use properly m For using the CCTV testerPRO safely please first read the Safety Information carefully in the manual m The manual shoul

Download Pdf Manuals

image

Related Search

Related Contents

和気修方説明書 へのリンク  MANUAL PPFE INOX 2014-01 PORTUGUES  ROLINE DesignSecure Manual  PT-38 - ESAB Welding & Cutting Products  Sony STR  Frigidaire FBD2400KB Product Specifications Sheet  Lux Products PSDH121 Thermostat User Manual  PMS-1718-B3  Linux/UNIX Platform Ref  BALLON TAMPON RéVERSIBLE  

Copyright © All rights reserved.