Home
        tig brush tbe
         Contents
1.  3   4     5   6   G    Attach connector of red cable to red connector of TIG  Brush Unit    Screw wand into handle    Place shroud on brush and screw into wand    Attach connector of black cable to black connector of  TIG Brush Unit    Set POWER switch to    OFF       Attach power cord to mains outlet and TIG Brush Unit   Attach clamp to workpiece     CLEANING FLUID    Pour a small quantity of the Cleaning Fluid into a shallow  bowl  Place the container close to the work because the tip  will be dipped into the fluid regularly during operation     TBE 700 Instruction Manual  Oct 2013  USA     S4 OPERATION             Workpiece          Wand  Shroud       Brush    Insulating shroud For best performance  must be used use tip of brush only    Ensitech Pty Ltd    13  www tigbrush com    S4 OPERATION    4 4 OPERATION    Refer to illustrations on pages 13 and 15     1     Aa    A     10     11     14    Set POWER control to STANDBY  Always use this setting  when connecting the clamp or changing the tip    Ensure the power cord is connected to a suitable 110V  AC power outlet and connected to the TIG Brush power  socket    Turn the On Off switch to ON  The red band on the switch  should be visible    Make sure the brush tip has its insulating shroud and the  insulation on the wand is undamaged    Ensure the TIG Brush is switched on and all equipment is  correctly connected as described above in section 4 2   Select power level and operating mode using the rotary  switches  See sect
2. Manual  Oct 2013  USA     S2 SAFETY PRECAUTIONS    e Fluid spilled on the skin should be washed off as soon  as practical    e Material Safety Data Sheet is available for all fluids and  should be read before use    e The brush gets extremely hot  around 392  F degrees  Fahrenheit  Be very careful touching the brush  Do not  place the brush near any flammable materials    e The TIG Brush produces an electric current which may  generate small sparks between the brush and the metal  being cleaned    e Hydrogen gas may also be generated  which is an  invisible but explosive gas   Always use the apparatus  in a well ventilated area  Do not use near flammable  substances  or in areas where dense flammable gases   such as petrol vapor  may accumulate    e The TIG Brush TBE 700 uses 110V AC only  Do not use  with any other voltage  If the power cord is damaged  or if the TIG Brush has been dropped from a height and  damaged  do not use the unit  Contact your TIG Brush  supplier to have the TIG Brush inspected  and repaired    e Do not short out the terminals  or use the TIG Brush with  a damaged wand or cables  Doing so may permanently  damage the TIG Brush and cause damage to the  workpiece being cleaned  The high currents involved  may also cause intense heating of the shorted or  damaged part  which could result in burns to  the operator    e     Ensure that the TIG Brush is located where it cannot  easily fall and cause injury  Ensure that the cables do  not present a trip hazar
3. TIG Brush TBE 700    Stainless Steel Weld Cleaning System    Operation  Safety and  Maintenance Manual    a MADE          bus     lt     Ensitech Pty Ltd TBE 700 Instruction Manual  www tigbrush com Oct 2013  USA     FOREWORD    FOREWORD    This manual is a very important tool  Keep it  with the machine at all times     The purpose of this manual is to provide users  with the necessary operating procedures and  precautions  essential for the safe and proper  operation of the TIG Brush     Due to continuous improvements  Ensitech    Pty Ltd reserves the right to make specification  changes       2011 Ensitech Pty Ltd    2 TBE 700 Instruction Manual  Oct 2013  USA     FOREWORD    SAFETY ALERT SYMBOLS AND SAFETY SIGNAL WORDS    AN WARNING    THIS IS THE SAFETY ALERT SYMBOL  IT IS USED TO ALERT  YOU TO THE POTENTIAL PERSONAL INJURY HAZARDS  OBEY  ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO  AVOID POSSIBLE INJURY        CAUTION    INDICATES AN IMMEDIATELY HAZARDOUS SITUATION  IF NOT  AVOIDED  MAY RESULT IN MINOR OR MODERATE INJURY  IT  MAY ALSO ALERT AGAINST UNSAFE PRACTICES     CORROSIVE  8    THIS SYMBOL INDICATES A HAZARDOUS SUBSTANCE WHICH  MAY CAUSE MINOR OR MODERATE INJURY  SOME TIGBRUSH  KITS MAY SHIP WITH HAZARDOUS FLUIDS  CHECK MATERIAL  SAFETY DATA SHEETS CAREFULLY     SYMBOL FOR    VOID WARRANTY    OR    DAMAGED WORK          Ensitech Pty Ltd 3    www tigbrush com    FOREWORD    FOR     e Accident reporting   e Product safety publications   e Current owner updates   
4. but you must pay all other costs including all transport costs of returning the defective goods to  Ensitech and Ensitech delivering the repaired or replacement part back to you     How to make a claim  If you want to make a claim under your warranty  please contact Ensitech Pty Ltd in writing by sending a    pre paid letter to Ensitech Pty Ltd  PO Box 179  Springwood NSW 2777  Australia  or email to info tigbrush   com  You must include your full name  address and contact telephone number and the details of the defect in  relation to which you make your claim  Ensitech will tell you whether you need to return the goods to Ensitech  Pty Ltd or the approved local distributor  You will need to return the goods together with all accessories and    parts for a full assessment and report     Additional limitations  exclusions and requirements   This warranty does not extend to      consumables such as the brush  insulating shroud and wand       any defect caused by normal wear and tear or incidental or inconsequential damage       any defect caused by misuse  negligence or other abuse of the goods      any defect caused by accidents or alterations      goods that have not been cleaned and maintained in accordance with the user s manual supplied with the  goods      loss or damage  including consequential loss or damage  to your work or facilities arising out of or in  connection with the use of the TIG Brush  or     unless otherwise expressly stated  any right to be reimbursed or 
5. compensated for physical or financial  injury  loss  damage  expense  time or inconvenience  whether direct or indirect  arising out of the  occurrence of the defect in the product or your inability to use the product        Model  TBE 700 Serial No     Date of Purchase        O Purchased from   e        ensitech TIG Brush TBE 700 Instruction Manual Oct 2013  USA     Ensitech Pty Ltd Unit 1 144 Old Bathurst Road  Emu Plains NSW 2750  Australia  Phone   61 2 4735 7700 Email  info tigbrush com    
6. d     O i A caution       Ensitech Pty Ltd 9    www tigbrush com    S3 DESCRIPTION OF BASIC APPARATUS           D TIG Brush Control Unit     Clamp Cable     Handle Cable       Handle        Wand        Shroud      Brush     Single brush may be replaced by  Power Cord dual or quad brush adapters        10 TBE 700 Instruction Manual  Oct 2013  USA     S3 DESCRIPTION OF BASIC APPARATUS    Power Control    Mode Control    Wand Socket    Clamp Socket                         On Off Switch    Mains Socket    USB Expansion  Port                                                                                  Ensitech Pty Ltd 11    www tigbrush com    S4 OPERATION    41 PREPARATION    LN    4 2    4 3    12    Inspect unit and all cables for damage before use   Ensure the unit is dry    Ensure the work environment is well ventilated and  away from any combustible substances    Ensure that cables do not present a trip hazard    If the items to be cleaned are small  place the parts in a  plastic container that can hold acidic fluids safely    Parts will need to be sprayed with the recommended  Ensitech neutralizer or washed down with water after  cleaning  Ensure there is ready access to water and a  suitable place for washing    Wear suitable personal protective equipment as  recommended in the MSDS  The minimum requirement  is for gloves to protect hands from the fluid  and goggles  to prevent fluid splashing into the eyes     ASSEMBLY    Refer to illustration on page 10     1     2  
7. e Questions regarding product safety   e Standards and regulations compliance information  e Questions regarding special product applications  e Questions regarding product modifications    CONTACT    Your local TIG Brush distributor   www tigbrush com     gt     ensitech       Ensitech Pty Ltd   Unit 1 144 Old Bathurst Road  Emu Plains NSW 2750  Australia    Phone   61 2 4735 7700  Email  info tigbrush com    4 TBE 700 Instruction Manual  Oct 2013  USA     REVISIONS LOG    Original Issue of Manual  August 2011  Revision  February 2012  Revision  October 2013    Ensitech Pty Ltd 5    www tigbrush com    S1 INTRODUCTION 7  S2 SAFETY PRECAUTIONS 8  S3 DESCRIPTION OF APPARATUS 10  S4 OPERATION 12  4 1 Preparation 12  4 2 Assembly 12  4 3 Cleaning Fluid 12  4 4 Operation 14  S5 POWER AND GRADE SETTING 15  5 1 Power Settings 15  5 2 Mode Settings 15  S6 MAINTENANCE 16  S7 CONSUMABLES 17  7 1 Brushes 17  7 2 Insulating Shroud 17  7 3 Fluids  e Pre Weld Cleaning Fluids 17  e Cleaning Fluids 17  e Neutralizing Fluids 17  e Finishing Fluid 17  e Marking Fluids 17  s8  TROUBLESHOOTING 18  8 1 Front Panel Power Light Not Illuminated 18    8 2 Front Panel Power Light Illuminated  amp  Unit Not Operating 19    6 TBE 700 Instruction Manual  Oct 2013  USA     S1 INTRODUCTION    INTRODUCTION    The TIG Brush is a metal cleaner polisher  It uses the action   of an electric current along with a fluid to remove heat marks  and other surface imperfections from metal surfaces  This  model has bee
8. for  dirt and contamination and clean if required     Contact your TIG Brush distributor or visit the website for  more help www tigbrush com    Ensitech Pty Ltd 19    www tigbrush com    WARRANTY   This warranty is given by Ensitech Pty Ltd of Unit 1 144  Old Bathurst Road  Emu Plains NSW 2750  Australia   Tel   61 2 4735 7700  Email  info tigbrush com The benefits given by each warranty set out in this document  are in addition to any other rights and remedies you may have under a law in relation to the services or goods  to which the warranty relates  Our goods come with guarantees that cannot be excluded under the Australian  Consumer Law  You are entitled to a replacement or refund for a major failure and for compensation for any  other reasonably foreseeable loss or damage  You are also entitled to have the goods repaired or replaced if  the goods fail to be of acceptable quality and the failure does not amount to a major failure  Unless otherwise  stated you will bear the cost of claiming the warranty     What this warranty covers   This warranty applies to any defects in the goods that appears within 24 months from the date of delivery  of the goods to you  To claim under this warranty  the defects must be notified to Ensitech and the goods  returned to Ensitech within two weeks of their appearance  Ensitech will  at its option  replace or repair   the goods within a reasonable time of receiving a valid warranty claim  Ensitech will pay for the repair or  replacement 
9. he switch should be visible    e Ensure the power cable is pushed completely into the  socket on the back of the TIG Brush    e     Ensure power is present at the power point  possibly by  plugging in another appliance  such as an  inspection light     e If the TIG Brush was being used prior to it turning off   the unit may have over heated  Wait 30 minutes for the  unit to cool down before trying to use it again     18 TBE 700 Instruction Manual  Oct 2013  USA     S8 TROUBLESHOOTING    8 2 FRONT PANEL POWER LIGHT  ILLUMINATED  amp  UNIT NOT OPERATING    e Ensure the Power Control is not set to STANDBY    e Ensure the cables are securely plugged into the front of  the TIG Brush    e     Ensure the clamp is gripping the work securely   Sometimes the clamp position may need adjusting to  make a good contact  If dirt or debris has built up on the  clamp  clean it as this may prevent a good contact  being made    e     Ensure the brush is wet with fluid    e     Ensure that the work is conductive  If the metal has a  plastic film or a thick layer of oxide  the current cannot  flow through the work  A mechanical or chemical  method may need to be used to remove any insulating  film before the TIG Brush can be used    e Examine all cables for damage and ensure they are  properly connected    e     Ensure the brush is securely screwed into the wand    A NOTE  Be careful when checking  as a loose connection  may be extremely hot    e Check screw threads on the handle  wand and brush 
10. ion 5 below for details    Dip brush in cleaning fluid and apply brush tip to weld  area to be cleaned  Use only recommended cleaning  fluids  see S7 2    Ensure brush and work area remain wet with the fluid  during cleaning    Apply brush only for as long as necessary to remove  discoloration  Prolonged application may affect   surface quality    Some light sparking may occur where brush tip contacts  workpiece  particularly on higher power settings  and this  is normal  Excessive sparking for a prolonged time in one  area may cause surface pitting    When desired surface finish is achieved  turn the TIG  Brush Power Control to OFF       After use put the brush down on a non flammable    surface as it may be very hot     13  Be careful touching the work as it may be hot   14  Rinse thoroughly with clean water to remove all traces of    cleaning fluid  To ensure acidic residue is removed  use  the recommended Ensitech neutralizing fluid  see S7 3     TBE 700 Instruction Manual  Oct 2013  USA     S5 POWER AND GRADE SETTINGS    5 1 POWER SETTINGS    Choose the cleaning intensity reguired by selecting the  appropriate setting using the Power Control        STANDBY   Power is not transmitted to the brush   IN     NARROW BRUSH   Use for light work and thin metals     ch     WIDE BRUSH   Use for most cleaning operations  Provides  fastest cleaning speed           A NARROW BRUSH  ED WIDE BRUSH  CLEAN  A RESTORE         SURFACE  MARKING  5 2 MODE SETTINGS    Choose the type of cleani
11. n specifically designed to clean heat marks left  by TIG welding stainless steel     Several cleaning solutions are available  each suited to  different applications  Contact Ensitech for more information   or visit our website www tigbrush com    Ensitech Pty Ltd 7    www tigbrush com    S2 SAFETY PRECAUTIONS    SAFETY PRECAUTIONS    Protect yourself and others by observing all safety  information  warnings and cautions  Failure to comply with  instructions could result in personal injury and or damage to  the product or property        Read this documentation carefully before operating the  eguipment  Please retain these instructions for future  reference     Before using the TIG Brush  make sure the work environment  is well ventilated and away from any combustible  substances  Ensure that all reguired eguipment is available     WARNING    Do not use the TIG Brush for any purpose other than that  described in this manual  Failure to observe this warning  may result in permanent damage to the TIG Brush  cause  damage to the workpiece  cause injury to the operator and  void the warranty     SAFETY INFORMATION    The TIG Brush is one of the safest appliances in its class   However some precautions must be taken with the use of  the TIG Brush  as with any electro cleaner     e The TIG Brush uses mild acids  gloves should be used to  avoid prolonged contact with any of the fluids    e Goggles should be worn to prevent fluid being splashed  in the eyes     8 TBE 700 Instruction 
12. ng required by selecting the  appropriate setting using the mode control       L   CLEAN   This mode provides the fastest cleaning at each  Y power setting  However  prolonged use may cause a milky  appearance on the surface of the metal  If this happens  use   RESTORE to rectify       D RESTORE   This mode provides metal polishing  Use this  grade to repair a dull white surface  including one caused by  over use of CLEAN        amp   MARKING   This mode provides surface marking  when used  with the appropriate brush setting and marking fluid     Ensitech Pty Ltd 15    www tigbrush com    S6 MAINTENANCE    6 1 MAINTENANCE    16       When not in use  ensure the On Off switch is OFF  The  power light on the front panel should not be illuminated  and the red band on the On Off switch should not be  visible    Rinse brush with water to remove excess cleaning fluid   At completion of a work shift  unscrew brush from  wand  Remove the brush from the insulating shroud   and rinse brush  shroud and end of wand with water to  remove cleaning solution  Allow to dry before  re assembling    Before assembling the brush to the wand  coat threads  with copper filled anti seize compound  This will exclude  the acidic solution from the joints and prevent corrosion   Rinse clamp with water to remove solution and   prevent corrosion    Use a wet cloth to wipe fluid splashes off the TIG Brush  control unit  After some time splashes and marks may  accumulate and become difficult to remove     A
13. nti seize compound    Rinse brush  components  after use    TBE 700 Instruction Manual  Oct 2013  USA     S7 CONSUMABLES    Consumable supplies are available from authorized TIG  Brush distributors     7 1 BRUSHES    The brush will wear down with use and should be  replaced when the bristles reach approximately half an  inch in length     7 2 INSULATING SHROUD    The insulating shroud may become damaged or heat   affected  If this happens  replacement shrouds may be  purchased     7 3 FLUIDS    A range of genuine Ensitech fluids is available  Please check  with your local TIG Brush distributor for details of fluids available  in your region    Types of fluids include     e Pre Weld Cleaning Fluids  to remove dirt and oil prior to  welding to minimize contamination during welding    e Weld Cleaning Fluids  for cleaning and  optionally   polishing   Biodegradable and neutral fluids are available     e Neutralizing Fluids  to ensure removal of all cleaning fluid  residue    e Finishing Fluid  to provide a clean  mark free finish    e Marking Fluids  can be used with custom stencils to  indelibly mark metals     EAS      M o    Fluids Brushes Shrouds       Ensitech Pty Ltd 17    www tigbrush com    S8 TROUBLESHOOTING    If the TIG Brush is not operating correctly  please refer to the  following trouble shooting guide before contacting your TIG  Brush distributor     8 1 FRONT PANEL POWER LIGHT NOT ILLUMINATED    e     Ensure the On Off switch on the back is ON  The red  band on t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User instructions  Saframyl Modes et Travaux  Samsung HT-DS1100 User Manual  Bollettino selezione 300-Ex (  Samsung SFN-C35GBBL User Manual  Yamaha PortaSound PSS-795 Owner's Manual  Philips Micro Hi-Fi System MCB146  TANK-700-QM67W-MRAY_UMN_v1.00  Minka Lavery 4934-284 Instructions / Assembly  Écrire son journal    Copyright © All rights reserved. 