Home

N-Series User Manual

image

Contents

1. Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 18 2 6 2 Patching and Storing Fiber 1 Wrap the pigtails entering the patch tray at the rear fiber channel around the slack cable spools then connect them to the rear of their respective adapters 2 Pull the jumper cables into the left or right side of the tray and route these cables through the guides in the tray 3 Connect the jumper cables to the front side of their respective adapters Once these cables are in place attach gate clips to hold the cables in place 4 Close the patch tray Figure 28 Patch Tray in Chassis Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 19 2 7 Storing Cables You may use the N Series storage to store excess patch cords and as a cross over point for patch cords 1 Open the storage tray 2 Place the patch cords into the fiber channels 3 Secure the cords in the channel with the gate clips supplied with the tray 4 Route the cords around the spools to take up the slack 5 Close the tray Figure 29 Storage Tray in Chassis Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 20 Chapter 3 Service N Series Fiber Optic Ca
2. 20 PACING WEE 18 2 6 1 Patch Tray Cable Routing 55 tascs iecit senta tinent atu nU pat et aa SEE eiat enttbocusat 18 2 6 2 Patehing and Storing FID E 19 2 ODDO e 20 Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te I t Page i EIEC deco Ne E nire E 21 3 1 Owner ee 21 3 2 Technical SUPPO E I C Ee 21 3 3 In Warranty Service acacia ceecaanrstanetied antagaesccneeenaGaciGaadiaireldemlorteneiaweapigindis aes sgaetdcnantbaneiae 21 3 4 Out of EE 21 zesE acte iMac M 22 List of Figures Chapier 12 Descriptor 9e 1 ie te E e at 2 Figure 2 Splice Tray ooo DTE 2 Figure ee EM 3 Figure 4 N Series Chassis 4 d Mc M 3 Figure 5 Sample N Series Bay Configuration ccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeesnaeeeeeeeaes 4 Chapter 2 Installation onse onbbcebti basati oti tax bbb E ckk bL brtbbbb ide pinnate 7 Figure 6 E tee NEE 8 Figure 7 Attaching Rear ln 8 Figure 8 Cable Clamp E 8 Figure 9 Cable Attachment and Routing eere reiten rtp Phu nun C A RE RE RR EE Eia 9 Figure 10 Cable Attachment and Routing side view sesseeeeene 9 Figure 11 Back Cover of E 10 Figure 12 Opern Link Eerad 10 Figure 13 Securing Jacket RRE 11 Figure 14 Routing Subunits EE 11 Figure Edu o a Link A EE 11 Figu
3. 509 926 6000 Mexico 52 33 3836 37 52 e www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 21 3 5 Repacking for Shipment 1 Tag the equipment showing owner s name address and telephone number together with a detailed description of the problem 2 Use the original shipping container if possible If you do not have it package the equipment in a way to prevent shipping damage Include the RMA inside the container and legibly print the RMA number on the outside of the package near the shipping address 3 Insure the package NOTE Telect is not liable for shipping damage Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 e www telect com 2010 Telect Inc All Rights Reserved 138727 Te l E ct Page 22
4. chassis that do not have trays already installed 1 Line up the left side of the left tray guide with channel in the chassis 2 Line up the right side of the tray guide with channel in chassis Close tray until it clicks Attach front links if installed to fiber rout ing components 5 Open rear access door on chassis 6 Attach rear links to fiber routing compo nents Figure 7 Attaching Rear Links 2 3 Installing Cable Management 2 3 1 Installing Cable Management Hardware 1 Attach clamp Part 027 1000 1001 to either a mounting flange or directly to the rack using the supplied screw Cable a Figure 8 Cable Clamp Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 8 2 3 2 Securing Multi Fiber Cable 1 Attach cable to the rack above or below the unit and route the sub units to the desired location Figure 9 Cable Attachment and Routing Figure 10 Cable Attach ment and Routing side view 2 4 Splice Tray Cabling Instructions 2 4 1 Cable Preparation 1 Prepare cable for installation a Bring the cable to the proper dimensions before installing it into the splice tray 2 Telect recommends following the dimension guidelines however if more storage is desired the 900 micron length can be increased a From the overall jacket breakout to subunits should be 17 5
5. rear door 2 Gently pull links out of the back of the chassis 3 Open all visible link lids Figure 18 Open Links 4 Place 900 micron in location where the splice cassettes were located 5 Secure the overall jacket to the end link at the back of the chassis 6 Route the subunits through as many links as possible n Figure 19 Routing Subunits through Links 7 Close all visible link lids 8 Working from the FRONT of the bay slide the top tray out 9 Open the link lids that are now visible 10 Place the fiber subunits into the rest of the links Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 13 11 Close all visible link lids Figure 20 Cables in Splice Tray Continue from Step 15 in previous section Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 3 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 14 2 5 Splicing 2 5 1 Preparing and Protecting Multi Fiber Strands 1 Extend the cable s subunit from the cable clamp to the appropriate rear link on the N Series panel Figure 21 Rear Entry Link 2 Secure the subunit to the entry link with a cable tie threaded through the slots in the link Entry Cable Tie SubUnit Figure 22 Securing the Subunit 2 5 2 Routing and Securing Pigtails at the Chassis Bring the pig
6. N Series Fiber Optic Cable Management System User Manual Bees Telect CONNECTING THE FUTURE N Series Fiber Optic Cable Management System User Manual Part Number 138727 Copyright 2010 Telect Inc All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect Inc 1730 N Madson St Liberty Lake Washington Telect assumes no liability from the application or use of these products Neither does Telect convey any license under its patent rights nor the patent rights of others This document and the products described herein are subject to change without notice About Telect Telect offers complete solutions for physical layer connectivity power equipment housing and other network infrastructure equipment From outside plant and central office to inside the home Telect draws on more than 25 years of experience to deliver leading edge product and service solutions Telect is committed to providing superior customer service and is capable of meeting the dynamic demands of customer and industry requirements This commitment to customer and industry excellence has positioned Telect as a leading connectivity and power solution provider for the global communications industry Technical Support E mail getinfo telect com Phone 888 821 4856 or 509 921 6161 Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct
7. Page ii N Series Fiber Optic Cable Management System User Manual Table of Contents Ghapter 1 DeScriptiOm ME 1 ae ee 1 1 2 N Series Trays and Chassis ccccsccccceeeseceeeeseceeeeesaeeeeeeneeaeeeeeaeaeeeeenaeeeesnenaeeeeeeneasens 2 1 2 1 AU D 2 EE 2 1 23 Storage Eege 3 1 3 N Series Flexible Chassis Au 3 I iusserit itii E E a theta Eaa aR 4 1 4 1 El E 5 1 4 3 Environmental Specifications ssessssssseseseseeneeeeenn nennen 5 Chapter 2 installati n usecsoxxcnxatellsepxRe up ER RA RAR Ei ix daba EAR krass 7 2 1 Installation Consideratlorie uei i opt t errat EE Ute EN EIN ERR ea EUN NEES ob kN a UN Eddie 7 PN EE e EE EE 7 22 E Le DEN 7 2 2 1 Rack Mounting the N Series Chassis cccssssceceesececeeeeeeeeeeeneeeeseeneeseneeeneneeee Y 2 2 2 Installing Ie nt 8 2 3 Installing Cable Management ANEN 8 2 3 1 Installing Cable Management Hardware ssssseeem 8 2 3 2 Securing Multi Fiber Cable criteri re LE ENEE b orsa sag sa per E NR Ree 9 2 4 Splice Tray Cabling MN 9 2 41 Cable Preparation E 9 2 4 2 Tray Cabling Nee EE 10 2 4 3 Top Tray IteEEET tee ere 13 2 5 SPICINO E 15 2 5 1 Preparing and Protecting Multi Fiber Strands sseeesese 15 2 5 2 Routing and Securing Pigtails at the Chassis sseesese 15 2 5 3 Splice Tray Cable Routing iiie rei cmn near na cen a kan ro deve natia na urea xRuE 16 2 5 4 Splicing and Storing Fiber ET 17
8. SA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Page 2 Figure 1 Patch Tray Figure 2 Splice Tray Telect 1 2 3 Storage Trays Engineered to hold the excessive patch cord length increasingly found in today s network racks each tray stores up to 24 3 mm jumpers 1 3 N Series Flexible Chassis Telect N Series Chassis are designed to offer the ultimate in high cable termination density Chassis sizes range from 1 RU to 4 RU 19 inch width to fit any capacity requirement and maximize rack space The following chassis configurations are available 4RU high 6 tray chassis e 3 RU high 4 tray chassis e 1 RU high 1 tray chassis Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Page 3 Figure 3 Storage Tray Figure 4 N Series Chassis 4RU Telect 1 4 System Specifications Lea S gt 9 E V ON A A Q m 6 A a s Xo AM TPA e S 9 Ox 25 Fo G O a fa 213380 a Py 9 gt 2 924 PA Lars d 5 A o o d 24 De bai Qro xr me ES K N 01 PS SEN ER EC p TIS 4 00 101 40 106158 1 UPPER TROUGH N SERIES PATCH TRAY 24 PATCHES FC UPC CONNECTORS PATCH CORDS EXIT FRONT RIGHT N SERIES PATCH TRAY 24 PATCHES FC UPC CONNECTORS PATCH CORDS EXIT FRONT LEFT N SERIES 4RU CHAS
9. SIS HOLD UP TO 6 TRAYS MAX CAPACITY 144 PATCHES OR 144 SPLICES N SERIES SPLICE TRAY 24 SPLICES PER TRAY TOTAL REAR ACCESS MANAGEMENT PANEL WITH LARGE CAPACITY SPOOLS 106159 1 LOWER TROUGH Figure 5 Sample N Series Bay Configuration Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Page 4 Telect 1 4 1 Mechanical 1 4 1 1 Dimensions 4 RU Chassis 19 W x 7 H x 10 4 D 483 mm W x 178 mm H x 264 mm D 3 RU Chassis 19 W x 5 25 H x 10 4 D 483 mm W x 133 mm H x 264 mm D 1 RU Chassis 19 W x 1 75 H x 10 4 D 483 mm W x 44 mm H x 264 mm D Minimum bend radius 30 mm throughout system Laser radiation protection Adapter location prevents exposure 1 4 1 2 Connections Termination count Up to 144 per chassis Termination type SC UPC SC APC FC UPC LC UPC Supported multifiber cables IFC Supported patch cables Simplex or duplex 2 0 mm recommended 3 0 mm 1 4 3 Environmental Specifications Humidity 0 to 90 non condensing Temperature 5 to 55 degrees C Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 e www telect com 2010 Telect Inc All Rights Reserved 138727 Te l E ct Page 5 This page intentionally left blank Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 e www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 6 Chapter 2 Installation N S
10. This allows the overall jack et to be secured to the back of the chassis and the subunits to be secured at the exit of the links b The 900 micron length should be 105 This allows three loops around the spools and also two loops inside the splice tray c Each external loop is approximately 15 75 Each loop in the splice tray is approximately 18 Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 9 2 4 2 Tray Cabling Instructions These instructions apply to all trays except the top tray in each chassis Working from the FRONT of the bay open the tray you intend to cable Remove the splice cassettes from the tray by removing the center screw Close the tray Slide all trays above the tray you are cabling out a de ro de Working from the BACK of the bay remove back cover from chassis to expose links Figure 11 Back Cover of Bay 6 Push all links from above trays to the sides of the chassis 7 Open all link lids on the incoming path Figure 12 Open Link Lids 8 Place the coiled 900 micron fiber in the area from where the splice cassettes were removed Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 10 9 Secure overall jacket to end link at back of chassis Figure 13 Securing J
11. acket to Link 10 Route subunits through the links 11 Close all link lids Figure 15 Closed Link Lids 12 Working from the FRONT of the bay slide all trays above the tray you are cabling in 13 Slide the tray you would like to cable out Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 11 14 15 16 17 18 19 20 21 22 23 24 25 Secure the fiber at the exit of links be A A cu Figure 16 Securing Fiber at Exit Place first splice cassette in chassis Wind fibers 1 12 around the storage spools Enter the splice cassette and secure fibers to cassette with tie Place lid on splice cassette T ei Figure 17 Lid on Splice Cassette Place the next splice cassette on top of the first one Wind fibers 13 24 around the storage spools Enter the splice cassette and secure fibers to cassette with tie Place the lid on the splice cassette Secure both cassettes with screw removed in Step 2 Continue with the rest of the trays in the chassis When finished with all trays re install the rear door Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 12 2 4 3 Top Tray Installation These instructions apply to the topmost tray only 1 Working from the BACK of the bay remove the
12. ble Management System 3 1 Owner Maintenance Telect s N Series Cable Management System does not require any preventative maintenance If equipment is not working properly contact technical support and be advised of the following warning and alert WARNING Fiber cables transmit laser or invisible infrared light To avoid eye damage or blind ness never look directly into fibers or connections 1 ALERT ALERT Only qualified technicians may install and maintain this product 3 2 Technical Support By e mail getinfo telect com By phone 888 821 4856 or 509 921 6161 3 3 In Warranty Service Contact your Telect equipment distributor or call a Telect Customer Service Representative 1 800 551 4567 1 509 926 6000 Telect will repair or replace defective products within the limits of the warranty See Repacking for Shipment in this section NOTE Call a Customer Service Representative for a Return Material Authorization RMA before returning any equipment 3 4 Out of Warranty Service The procedure for out of warranty service is the same as for in warranty service however Telect charges a processing fee You must submit a Purchase Order along with a Return Material Authorization RMA before returning equipment Call a Customer Service Representative for assistance in acquiring these forms The processing fee guarantees a repair estimate and is credited against actual material and labor costs Telect Inc e USA 1
13. eries Fiber Optic Cable Management System 2 1 Installation Considerations These installation procedures address patch trays in the rear access and front rear access configurations Each chassis comes with a 19 or 23 rack mount bracket with fiber routing components installed and the necessary screws for mounting The following equipment is required for installation fiber cable preparation tools and materials e screwdrivers e test set 2 1 1 Inspection Compare the contents of the N Series shipping container with the packing list to ensure all of the components are there Contact Telect or your supplier if anything is missing 1 800 551 4567 or getinfo telect com Telect is not liable for shipping damage If the shipping container is damaged keep it for the carrier s inspection Notify the carrier Keep the container until you have checked equipment operation If you experience any problems contact Telect at the number or e mail above 2 2 Installing Trays 2 2 1 Rack Mounting the N Series Chassis 1 If possible mount the chassis intended for splicing between 20 and 50 from the floor for easy access and central location 2 Mount the chassis to the rack with four 12 24 mounting screws Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 e www telect com 2010 Telect Inc All Rights Reserved 138727 Te l E ct Page 7 2 2 2 Installing the Trays This procedure provides instructions for
14. ies three types of chassis three types of trays patch splice and storage routing and protection hardware for fiber cable e multifiber cable assemblies and 2mm or 3mm fiber cable assemblies N Series chassis come in three sizes singe tray four tray and six tray configurations Each metal chassis includes a rear access door spring loaded door latches cable management hardware and mounting screw The following are the three types of trays that can be placed in the N Series chassis Splice rear access IFC and pigtails enter tray from rear left rear right front combination right rear left front IFC and pigtails enter trays from front and rear e Patch Storage Each plastic tray includes provision for slack cable cable management hardware designation strips and warning labels Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l E ct Page 1 1 2 N Series Trays and Chassis 1 2 1 Patch Trays Pre configured N Series patch trays help to minimize installation time and manage cable All standard network capacities and connector types are available 1 2 2 Splice Trays The N Series line includes splice trays with heat shrink fusion splices for applications where patches and splices must be segregated in separate trays Fiber counts range includes 12 and 24 fibers to match standard applications Telect Inc e U
15. re 16 Securing Fiber at EE 12 Figure 17 Lid on Splice Cassette AAA 12 Figure 18 Open LINKS em E 13 Figure 19 Routing Subunits through Links auae to edet etaed Eege eege 13 Figure 20 Cables in Splice Tra 14 Figure 21 liccc pa ln 15 Figure 22 Securing the Subunit irpo pel ctae ausi eege 15 Figure 23 Channel Detachment AAA 16 Figure 24 Gat CIPS E 16 Figure 25 Splice Tray Fiber Routing iced oria tor peine dE eacto tacos Resta rh datendtesseeeade 17 Figure 26 Channel Detachment AAA 18 Figure 27 Gale CMDS sense Datei P a MM NE UND D M uus M EN DNE ME EC MEE 18 Figure 28 Patch Tray in Chassis RET MR 19 Figure 29 Storage Tray in Chassis iuuenes siint ta secet en uer EENS SEEEEdASEE EELER 20 Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te I t Page ii amp C Chapter 1 Description N Series Fiber Optic Cable Management System 1 1 Overview N Series is an advanced integrated fiber optic cable management system It provides a central location for fiber splicing patching and storage It includes a chassis one or more trays and accessories N Series is designed for a 19 or 23 equipment racks and can accommodate central office outside plant and customer premise environments N Series is a completely integrated system Depending on the configuration you order it can include network frame relay racks and accessor
16. signation strip Reattach the splice compartment cover and close the splice tray Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 17 2 6 Patching 2 6 1 Patch Tray Cable Routing 1 2 9 Open the patch tray Detach the fiber channel from its tray link in either of two ways Channel GEN In e Lift up on the locking tab of the tray link with a small screwdriver and pull off the channel Using the following four step procedure Remove the tray link screw Close the patch tray and detach the channel Figure 26 Channel Detachment from its entry link c Push a small screwdriver into the last small hole underneath the attachment point to release the locking tab d Pull the channel from the entry link Remove the channel from the tray Open gate clips on fiber channel to Place the pigtails into the fiber channel that connects to SCH cin p 2 the rear of the tray EUN SCH m Place the jumper cables into the channel that connects eg to the side of the tray Secure multi fiber pigtails in the channel by closing Q le ee gate clips iae e ts Slide the tray link end of the fiber channel back into the Figure 27 Gate Clips patch tray Snap the attachment link of the fiber channel onto the appropriate LINXS chassis entry link 10 Open the tray and reattach the channel s tray link
17. tails for splicing to the appropriate entry link on the side opposite of where the multi fiber cable enters the splice tray Loosely secure the bundle to the link with a cable tie threaded through the slots in the link Do not tighten the cable tie at this time Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 15 2 5 3 Splice Tray Cable Routing 1 To route the multi fiber or pigtails within the splice tray remove the fiber channel from the side of the tray Open the splice tray and remove the plastic splice compartment cover Channel Attachment Detach the fiber channel from its tray link in either of Link the following two ways Lift up on the locking tab of the tray link with a small screwdriver and pull off the channel Using the following four step procedure e Figure 23 Channel Detachment Remove the tray link screw l Close the splice tray and detach the channel from its entry link c Push a small screwdriver into the last small hole underneath the attachment point to release the locking tab d Pull the channel from the entry link Remove the channel from the tray Open the gate clips on fiber channel x Qa Place the multi fiber subunits or pigtails into the fiber SE ol channel 9 Secure multi fiber pigtails in the channel by closing E d gate clips al the splice tray and snap or screw
18. the tray link back into position Channel Links Slide the tray link end of the fiber channel back into Q e Figure 24 Gate Clips Snap the attachment link of the fiber channel onto the appropriate entry link Remove the jacket from the pigtails at the point where they just extend beyond the tray link before entering the routing guides Telect Inc e USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 138727 Te l ct Page 16 11 Place the fibers and the pigtails into the routing guides at the rear of the splice tray Guide the fibers and the pigtails behind both spools and down to the front of the splice tray Fibers and pigtails should cross each other behind the spools Figure 25 Splice Tray Fiber Routing 2 5 4 Splicing and Storing Fiber Do not remove the splice tray when splicing cables 1 DGD gr dee opes Ju Guide two fiber strands into the rear most splice position Adjust their lengths by spooling the slack so that after splicing they will lay neatly across the splice tray Unspool the two fibers and move them to your splice table Prepare the fibers then splice them according to the splice manufacturer s instructions Rewrap the slack around the spools and place the completed splice into the splice pad Repeat steps 1 through 4 for remaining splices working toward the front of the splice pad Identify each splice on the tray s de