Home
CIP User Manual & Installation Guide
Contents
1. 1 Introduction EtherNet IP better known as the Common Industrial Protocol CIP was designed for use in process control and industrial automation applications CIP was designed to provide consistent device access to eliminate the need for vendor specific software for configuration and monitoring of individual devices N TRON switches with CIP support can be used to communicate with other industrial devices such as Rockwell controllers 2 CIP Components The following CIP components are available with N TRON CIP enabled switches 2 1 Electronic Data Sheet EDS An electronic datasheet for each N TRON switch is provided In a Rockwell environment EDS files are installed using the EDS Hardware Installation Tool This allows N TRON switches to be recognized in an RSLinx environment 2 2 CIP Objects Objects are used to organize various information about the switch There are four types of objects provided Three are specified by the ODVA and one is N TRON specific gt Identity object gt TCP IP Interface object gt Ethernet Link object gt N TRON switch object Standard services are associated with objects Services exist for reading an attribute setting an attribute resetting a device etc See references 1 and 2 for specific details The following sections describe the attributes associated with each object type such as attribute Id number and data format All attributes can be read but only
2. Times that the carrier sense condition was lost or never asserted when attempting to transmit a frame Frame_Too Long DINT Frames received that exceed the maximum permitted frame size MAC Receive_Errors DINT Frames for which reception on an interface fails due to an internal MAC sub layer receive error Control Bits INT 0 Auto negotiate 0 indicates 802 3 link auto negotiation is disabled 1 indicates auto negotiation is enabled If auto negotiation is disabled then the device shall use the settings indicated by the Forced Duplex Mode and Forced Interface Speed bits 1 Forced Duplex Mode If the Auto negotiate bit is 0 the Forced Duplex Mode bit indicates whether the interface shall operate in full or half duplex mode 0 indicates the interface duplex should be half duplex 1 indicates the interface duplex Forced_Interface Speed INT Speed at which the interface shall be forced to operate Speed in Mbps 10 100 1000 etc Interface Type SINT 0 unknown 1 internal 2 twisted pair 3 optical Interface_State SINT 0 unknown 1 enabled and ready 2 disabled 3 testing Revision March 2014 Page 33 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Admin_ State SINT 1 enable
3. reset switch or restore factory configuration 14 Get Attribute Single yes yes yes yes 16 Set Attribute Single Attributes Attributes Attributes Attributes 15 17 3 5 6 9 102 14 15 19 23 104 Vendor Specific 50 Get All Attributes yes yes including vendor defined attributes Object Specific 76 Get_And Clear Attributes 4 5 2 4 Accessing Data 2 4 1 Explicit Messaging Explicit messaging refers to a request response form of communications over a CIP TCP IP connection Applications can use explicit messaging for example to invoke the Get All Attributes service and read all attributes of the Identity object 2 4 2 I O Connections T O connections are used to send data grouped in assemblies between devices periodically The interval between sends is the Requested Packet Interval or RPI The N TRON switch assemblies Input Output and Configuration are defined in the following table N TRON switch Assembly Number Size bytes Input to switch 101 4 Output from switch 102 104 Configuration 103 0 not currently used Revision March 2014 Page 11 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation In an RSLogix 5000 environment these assemblies are configured in the Connection Parameters panel of the Generic Ethernet Module Note that input and output assemblies are reversed More inform
4. Name Description Size 32 bit Output 101 1 32 bit Comm Format Data DINT Address Host Name Oi IP Address 192 168 Configuration 103 0 8 bit Status Input Host Name status Uuitput Cancel Apply Help Status Offline Click the Connection tab and set the desired RPI The input assembly will be received from the switch at the selected RPI Revision March 2014 Page 15 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation UE FrOpertl EPI CACCIA General onnection Module Info Requested Packet Interval RPI 3200 0 ms 1 0 3200 0 ms Inhibit Module E Major Fault On Controller If Connection Fails While in Run Mode Use Unicast Connection over EtherNet IP Module Fault Status Offline Click OK The new module will appear in the I O Configuration tree 1 0 Configuration E em Backplane CompactLogix System flg 1769 L35E Demo 4 1769 L35E Ethernet Port LocalENB Ethernet 4 1769 L35E Ethernet Port LocalE ETHERNET MODULE N228 CompactBus Local Create a new rung in the MainRoutine and add the AOI for your specific switch to the rung Revision March 2014 Page 16 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation AOL AOL AOL AOL AOL AOL AOL AOL NTR NTR N
5. 1 as described for the NTRON NT24k graphic object For more information on the displays including screenshots see the Faceplate Quick Reference FactoryTalk View SE Client setup Factory Talk View SE Client Components Select components Components Initial display Display parameters Initial client key file Startup macro Shutdown macro Help About Cancel Revision March 2014 Page 47 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation FactoryTalk View SE Client Window Properties Specify the properties of the FactoryT alk View SE Client window IV Show title bar Title bar text Hon Faceplates IV Show system menu and close button IV Show Min Max buttons Maximize window IV Show Diagnostics List J Allow undocking of Diagnostics List Disable switch to other applications Help About Cancel 5 2 Sample Project Refer to the ME or SE sample project archive named NTRON_demo apa If you have any suggestions for improving the faceplates or the installation instructions please send them to email with subject FactoryTalk Faceplates Revision March 2014 Page 48 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 6 Rockwell FactoryTalk Faceplate quick reference guide 6 1 Introduct
6. Classl Connections INT Number of CIP EtherNet IP class I multicast connections Class3 Connections INT Number of CIP EtherNet IP class 3 unicast connections Temperature C INT Temperature in degrees Celsius 0x7FFF Not supported on device Temperature F INT Temperature in degrees Fahrenheit 0x 7FFF Not supported on device CPU_ Utilization SINT Percent of CPU usage 0 100 Contact_Status SINT 2 Bits per contact 00 Not Present 01 Open 10 Closed Utilization 1 Utilization 2 Utilization 3 SINT bandwidth utilization in percent Utilization 62 Utilization 63 Utilization 64 Update Counter INT 4 2 NT24k assembly tags Data Type UDT NTRON Switch NT24k In v0 Specific view of assembly data received from an N TRON NT24k Switch Name Data Type Description System Faults UDT NTRON Status of various system faults System Fault s NT24k v0 Admin Status DINT Admin Status of first 32 ports Also available as port specific tags Admin Status Al BOOL 1 enabled 0 disabled Revision March 2014 Page 27 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Admin Status A8 Admin Status Bl Admin Status B 8 Admin Status C1 Admin Status C8 Link Sta
7. Contact Status SINT 2 Bits per contact 00 Not Present 01 Open 10 Closed Temperature C INT Temperature in degrees C Only available on devices that support temperature Temperature F INT Temperature in degrees F Only available on devices that support temperature Reset MIB Counts DINT 2 Reset port MIB counters 1 bit per port to reset Device MAC Address SINT 6 MAC address of device Device_Role DINT Bit mask of device roles Bits 0 N Ring Manager 1 N Ring Member 2 N Ring AutoDetect 3 N Link Master 4 N Link Slave 5 N Link Coupler Config Device Status SINT 0 Not Supported 1 Not Present 2 Present System Configuration DINT Bit mask of system config Bits 0 Save system configuration to flash 1 Shutdown and reboot device System Firmware Versi STRING Human readable representation of firmware on String version string System Boot Loader Ve STRING Human readable representation of boot loader rsion String version string System Fault String UDT NTR Human readable representation of error status ON Stringl May contain multiple errors Length is contained Revision March 2014 Page 35 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 024 as part of the STRINGI data type Power Configuration DINT 4 Bits per power supply 0000 DC Power 0001 AC Power 1111 Unknown Power supply 1 config
8. InUnknownProtos DINT Inbound packets with unknown protocol OutOctets DINT Octets sent on the interface OutUcastPackets DINT Unicast packets sent on the interface OutNucastPackets DINT Non unicast packets sent on the interface OutDiscards DINT Outbound packets discarded OutErrors DINT Outbound packets that contain errors Revision March 2014 Page 32 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Alignment_Errors Frames received that are not an integral number of octets in length FCS Errors Frames received that do not pass the FCS check Single Collisions Successfully transmitted frames which experienced exactly one collision Multiple Collisions Successfully transmitted frames which experienced more than one collision SQE Test Errors Number of times SQE test error message Is generated Deferred Transmissions Frames for which first transmission attempt is delayed because the medium is busy Late Collisions DINT Number of times a collision is detected later than 512 bit times into the transmission of a packet Excessive Collisions DINT Frames for which transmission fails due to excessive collisions MAC Transmit Errors DINT Frames for which transmission fails due toan internal MAC sub layer transmit error Carrier_Sense_Errors DINT
9. Libraries i Add Component Into Application Local Messages 93 Alarms A Alarm Setup EA Inf akan Revision March 2014 Page 41 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Select the folder FactoryTalk_View_ME Display_export Install images containing the image files bmp Import all NTRON bmp files The Explorer window should show several new files Home_default NTRON alarm NTRON alarm bw NTRON alarm red NTRON_ diagnostics NTRON exit NTRON home NTRON Question Mark NTRON settings 5 Import tags using the Tag Import and Export Wizard Select the NTRON Tags CSV to import FactoryTalk View ME Display_export Install tags The result should be these tags Tag Name Type Description NTRON Help Digital 2 INTRON Settings Selection Analog 3 NTRON Trend Selection Analog 6 To access the faceplate displays create a display using the global object NTRON NT24k Display File gt New gt Display Select all objects in the NTRON NT24k Display global object and paste them into the new display Save the new display Configure a macro for opening your display Here is the ME form for this example Ei NTRON Open 228 INTRON demo Macros Form lt Tag gt lt Expression gt Tag Tag Expression Exprn 1 PLC N226Params Control HMI O Display_Mode 2
10. Port Role RSTP Bandwidth Utilization 0 RX Broadcast FPS 0 TX Broadcast FPS 0 RX Multicast FPS 6 TX Multicast FPS 3 RX Unicast FPS 2 TX Unicast FPS 1 Port Errors 0 Sunday September 15 2013 2 27 40 PM 2 29 40 PM The following table describes fields and values Field Values Description Link Up Yes Current link state No Speed Duplex 10 Full This configurable field displays the current speed and 100 Full mode of the port 1000 Full 10 Half 100 Half Unknown Admin Enabled Yes This configurable field displays the existing status of the No port whether it is Enabled Disabled Revision March 2014 Page 52 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Port Role RSTP The role of the port which is based on the switch N Ring configuration Some combinations are possible For more N Link Control details see the user manual for the NT24k switch family N Link Partner RSTP N Link Partner N Ring N Link Partner N Link Coupler RSTP N Link Coupler Bandwidth Utilization 0 100 percent Bandwidth utilization displayed as a percentage RX Broadcast FPS The frames per second rate of received broadcast frames TX Broadcast FPS The frames per second rate of transmitted broadcast frames RX Multicast FPS The frames per second rate of received multicast frames TX Multicast
11. Revision March 2014 Page 7 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Carrier Sense Errors UDINT 32 0 Not available Times that the carrier sense condition was lost or never asserted when attempting to transmit a frame Frame Too Long UDINT 32 Frames received that exceed the maximum permitted frame size MAC Receive Errors UDINT 32 0 Not available Frames for which reception on an interface fails due to an internal MAC sub layer receive error 6 Interface Control STRUCT of Control Bits Set WORD 16 Interface Control Bits Includes auto negotiation and duplex settings Forced Interface Speed Set UINT 16 Speed at which the interface shall be forced to operate Speed in Mbps 10 100 1000 etc 7 Interface Type USINT 8 Type of interface twisted pair fiber internal etc 8 Interface State USINT 8 Current state of the interface operational disabled etc Admin State Set USINT 8 Administrative state enable disable 10 Interface Label SHORT_STRI Human readable identification TX1 FX1 NG GB1 A4 C8 etc 100 Interface Description SHORT STRI Human readable description For example NG Port 1 10 100 Mbit TX Port 15 100 MBit FX 101 Interface Utilization USINT 8 Percentage of entire interface bandwidth being
12. used 0 100 102 Utilization Alarm Upper Threshold Set USINT 8 Upper percentage at which to declare utilization alarm 0 100 103 Utilization Alarm Lower Threshold Set USINT 8 Lower percentage at which to declare a utilization alarm 0 100 104 Broadcast Limit Set USINT 8 Broadcast limiting percentage 0 100 BPCL 105 TX Unicast Packet Rate UDINT32 Number of TX unicast packets per second 106 RX Unicast Packet Rate UDINT32 Number of RX unicast packets per second 107 TX Multicast Packet Rate UDINT32 Number of TX multicast packets per second 108 RX Multicast Packet Rate UDINT32 Number of RX multicast packets per second 109 TX Broadcast Packet Rate UDINT32 Number of TX broadcast packets per second 110 RX Broadcast Packet Rate UDINT32 Number of RX broadcast packets per second 111 TX Multicast Packets UDINT32 Total number of TX multicast packets 112 RX Multicast Packets UDINT32 Total number of RX multicast packets 113 TX Broadcast Packets UDINT32 Total number of TX broadcast packets 114 RX Broadcast Packets UDINT32 Total number of RX broadcast packets 115 Port Role UDINT32 Bit mask of port roles Bits 0 RSTP 1 N Ring 2 N Link Control 3 N Link Partner 4 N Link Coupler Revision March 2014 Page 8 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 2 2 4 N TRON Object The N TRON object Class code 0xC
13. Message Type CIP Generic v kli Set Attribute Single y Source Element N2285etData 0 Source Length 4 1 Bytes Service F Code j 0 Hex Class lts Hex Destination Instance j Attribute f1 Hex O Enable Enable Waiting O Start D Done Done Length 0 D Error Code Extended Error Code Timed Out Error Path Error Text Cancel Apply Revision March 2014 Page 20 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Message Configuration N228SetMsg Configuration Communication Tag Path NEZE Browse N228 r Communication Method CIP C DHe Chane Destination Link fo go CIR with Source Link fo Destination Node jo Octal j ource ID Connected V Cache Connections O Enable Enable Waiting Start Done Done Lenath 0 D Error Code Extended Error Code l Timed Out Error Path Error Text Cancel Help Verify your changes by clicking Logic gt Verify gt Controller If there are no warnings or errors the RSLogix configuration is complete Revision March 2014 Page 21 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 3 2 Input_Assembly Parameter Some data comes from the switch at the RPI requested packet interval set for the Generic Ethernet
14. Module The data is available in tags like these below a mapping of the Switch Inputs data NT24kInputAssembly NT24kInput ssembly System Faults NT24klnput ssembly dmin Status NT 24kInput ssembly dmin Status A1 NT24klnput ssembly dmin Status Z NT 24kInput ssembly Admin Status 43 NT24kInput ssembly dmin Status Ad NT24kInput ssembly dmin Status 5 NT 24klnput ssembly dmin Status AB NT 24kInput ssembly dmin Status 47 NT 24kInput ssembly dmin Status 48 NT24kInput ssembly dmin Status B1 NT24kInput ssembly dmin Status B2 NT 24klnput ssembly Admin Status B3 NT 24kInput ssembly Admin Status B4 NT24kInput ssembly dmin Status B5 NT24kInput ssembly dmin Status BE NT 24kInput ssembly dmin Status B7 NT 24kInput ssembly Admin Status B8 NT 24kInput ssembly dmin Status C1 NT24klnput ssembly dmin Status C2 NT 24kInput ssembly dmin Status C3 NT 24kInput ssembly dmin Status C4 NT 24kInput ssembly dmin Status C5 NT24kInput ssembly dmin Status C6 NT 24kInput ssembly dmin Status C7 NT 24kInput ssembly Admin Status C8 NT24klnput ssembly Link Status NT24kInput ssembly Link Status Al NT24kInput ssembly Link Status A2 NT24kInput ssembly Link Status 43 NT 24kInput ssembly Link Status Ad NT24kInput ssembly Link Status A5 These tags represent a switch specific NT24k view of the assembly data Revis
15. Product Name SHORT STRI Switch Model Number NG EX N Tron NT24k 15 Assigned Name Set STRINGI This is the user assigned switch name 17 Geographic Location Set STRINGI This is the user assigned switch location The table below defines fault bits within the Status attribute of the Identity object Revision March 2014 Page 4 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Bit Called Definition 8 Minor Recoverable Fault Power supply 1 Power supply 2 N Ring Full System Port utilization Temperature N Link partner is down N Link integrity fault Minor Unrecoverable Fault Configuration device error 10 Major Recoverable Fault N Ring partial low N Ring partial high N Ring multiple managers Boot loader version N Link partner port unknown N Link multiple masters N Link control fault N Link configuration fault Settings fault 11 Major Unrecoverable Fault none Revision March 2014 Page 5 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 2 2 2 TCP IP Interface Object The TCP IP Interface object class Class code 0xF5 and instance attributes are implemented as defined by CIP Vol 2 5 3 2 There is only one instance 1 of this object The following table s
16. Tag from screenshot PLCIN228Params Control HMI 0 Display Mode Here is the SE form Revision March 2014 Page 42 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Si NTRON_Open_228 NTRONSE Macros Macro File created 12 15 2009 I Macros are lists of commands with one command per line I See Help or the manual for a list of commands and their parameters amp PLC N228Params Control HMI 0 Display Mode 1 Tag from screenshot amp PLC N228Params Control HMI 0 Display Mode 1 In the macro definition and later in the parameter file the shortcut PLC was created earlier The other important piece is N228Params which is the name of the Switch Parameters tag created for the NTRON SWITCH AOI in your RSLogix project Example switch AOL NTRON SWITCH AOI for N TRON switch AOL NTRON SWITCH N228 ES Switch_Inputs N228 1 Data Switch_Output N228 0 Data 0 Switch_Parameters N228Params Get Message N228Gethsg Get Message Extended N228GetMsgExt Storage N228Storage Set_Message N228SetMsg SetData N228SetData In the Display Settings for the NTRON_NT24k_ Display open the NTRON_NT24k Display display Edit gt Display Settings click the Behavior panel and assign the newly created macro as the startup macro Display Settings General Behavior Macros Behavior o
17. data is copied to the UDT NTRON CIP DATA v0 data type Request Data BOOL 0 explicit messaging is disabled 1 explicit messaging is enabled Read Port Mask DINT Set bit n to read Ethernet Link object for port n 1 Explicit Messaging Timer DINT Used to control time between each MSG call to read CIP _ Reset Identity object TCPIP object N TRON object and selected Ethernet Link objects Minimum is 200 ms Default is 1000 ms Sample ladder logic rungs are available that show how to control explicit messaging 3 5 Troubleshooting Module Fault Code 160315 Connection Request Error Invalid segment type This error occurs when the assembly information specified for the Generic Ethernet Module does not match the assembly information on the N TRON switch Revision March 2014 Page 23 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 3 6 Sample Project A sample project is included in the CIP Installation Kit It is named NTRON Demo ACD To use the sample project you may need to change the controller type used in your environment and you will need to setup the Project path If you have any suggestions for improving the AOI or the installation instructions please send them to email with subject RSLogix5000 AOT Revision March 2014 Page 24 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email
18. seconds since device was powered up Port Count DINT Total port count Valid Ports DINT 2 0 Invalid port 1 Port exists on device Bit 0 Port I Bit 1 Port 2 etc Global Admin Status DINT 2 0 Port disabled 1 Port enabled Bit n Port n 1 Revision March 2014 Page 34 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Global Link Status DINT 2 0 Link down 1 Link up Bit n Port n 1 System Faults UDT NTR See System fault tags ON System _Faults NT 24k v0 IGMP Querier Status SINT Query Status 0 Disabled 1 Active manual 2 Active Auto 3 Backup Auto enabled but not active IGMP Version SINT IGMP Version V1 V2 V3 etc IGMP Resource Usage SINT Percent of maximum capacity Takes into account the number of groups used per max groups and any other possible resource limitations IGMP Active Querier DINT IP of the active IGMP querier CPU Usage SINT Percent usage Classl Connections INT Number of CIP EtherNet IP class I multicast connections Class3 Connections INT Number of CIP EtherNet IP class 3 unicast connections Temperature Alarm Upp INT Upper temperature C at which to declare an er Threshold alarm Temperature Alarm Lo INT Lower temperature C at which to declare an wer Threshold alarm
19. some can be set as shown by the Set column Revision March 2014 Page 3 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 2 2 1 Identity Object The identity object class Class code 0x01 and instance attributes are implemented as defined by CIP Vol 1 5 2 1 There is one instance 1 of this object Service code 0x32 will get all attributes including optional attributes The following table summarizes the attributes in the Identity object Name Set Format Description Vendor ID UINT 16 1006 This is N TRON s ODVA EtherNet IP Vendor ID Device Type UINT 16 0x0C Communications Adapter Product Code UINT 16 Switch product code NT24k 24001 NT24k DR16 24002 NT24k DR24 24003 Major Revision USINT 8 Major version of CIP implementation Minor Revision USINT 8 Minor version of CIP implementation Status WORD 16 Summary status of device Bits BitO Ifset device has an owner Bit I reserved Bit2 Ifset device has non default configuration Bit 3 reserved Bits 4 7 Extended device status not used Bit 8 Minor recoverable fault Bit 9 Minor unrecoverable fault Bit 10 Major recoverable fault Bit 11 Major unrecoverable fault Bits 12 15 reserved see fault table below Serial Number UDINT 32 Serial number of the device This is the last 4 octets of the base switch MAC
20. 0 is a vendor specific object and is implemented as defined by CIP Vol 1 4 1 There is only one instance 1 of this object The following table summarizes the attributes of the N TRON object Id Name Set Format Description 1 Device Up UDINT 32 Number of seconds since device was powered up Time 2 Port Count UDINT 32 Total port count 3 Valid Ports LWORD 64 0 Invalid Port 1 Port Exists on device AB DINT 2 Bit 0 Port 1 Bit 1 Port 2 etc 4 Global Admin LWORD 64 0 Port Disabled 1 Port Enabled Status AB DINT 2 Bit 0 Port 1 Bit 1 Port 2 etc 5 Global Link LWORD 64 0 Link Down 1 Link Up Status AB DINT 2 Bit 0 Port 1 Bit 1 Port 2 etc 6 System Faults DWORD 32 Bit 00 Power Supply 1 Bit 01 Power Supply 2 Bit 02 N Ring Fault complete Bit 03 N Ring Partial Fault low port Bit 04 N Ring Partial Fault high port Bit 05 N Ring Multiple Managers Bit 06 System error Bit 07 the configuration on an installed configuration device is invalid Bit 08 N Link Fault Bit 09 Boot loader version mismatch Bit 10 Port Utilization Alarm Bit 11 Temperature Alarm Bit 12 Settings fault 7 IGMP Querier USINT 8 Query Status Status 0 Disabled 1 Active manual 2 Active Auto 3 Backup Auto enabled but not active 8 IGMP Version USINT 8 IGMP Version V1 V2 V3 etc 9 IGMP USINT 8 Percent of maximum
21. 756 44 fa 0 1756 L62 Test Look in Ji AOL_export O P m I Name Date modified Type Computer LI VL gix l AOL NTRON NT24KDR24 vi 1 L5X 7 11 20133 50 PM RSLogix 5 File name Files of type RSLogix 5000 XML Files L5X Files containing Add On Instruction v Into Add On Instructions Revision March 2014 Page 13 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation The Add On Instruction tree showing an AOI for the NT24k switch and several auxiliary AOIs Add On Instructions 31 AOLNTRON CIP STRINGI Copy vi 0 dj AOL NTRON Common vi 1 AR AOLNTRON_IP_Address_to_String_v1_0 83 AOLNTRON_MAC_To String_v1_0 AR AOLNTRON_String_Copy2_v1_0 annen nine G AOLNTRON String Copy vl 0 ff AOLNTRON Sum Port Errors vil 0 S Data Types E E Add a Generic Ethernet Module to the I O Configuration Lg Predefined E Er Module Defined Trends E Ho Configuration D FAE am E Select Module 4 1769 L3SE Ethernet Port LocalENB EE Communications Digital Drives HMI The Generic Ethernet Module is located under the Communications group Revision March 2014 Page 14 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Ma
22. Coupler 22 Config Device BYTE 8 0 Not Supported 1 Not Present 2 Present Status 23 System Set UDINT 32 Bit mask of system config Bits Configuration Bit 0 GET Changes have been made that have not been saved SET Save system configuration to flash Bit 1 GET Changes have been made that require a reboot to take effect SET Shutdown and reboot device 24 System SHORT_STRI Human readable representation of firmware version Firmware NG string Version String 25 System Boot SHORT_STRI Human readable representation of boot loader Loader NG version string Version String 26 System Fault STRINGI Human readable representation of error status String May contain multiple errors Length is contained as part of the STRINGI data type 27 Power UDINT 32 4 Bits per power supply 0000 DC Power 0001 Configuration AC Power 1111 Unknown Power supply 1 configuration is in bits 0 3 and Power supply 2 configuration is in bits 4 7 Revision March 2014 Page 10 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 2 3 CIP Services The table following is a summary of the supported services as defined by CIP Vol 1 Appendix A Explicit Messaging Services 1 Service Service Description Identity TCP IP Ethernet N TRON Code Link 1 Get_Attributes All yes yes yes yes 5 Reset Yes
23. Disabled Revision March 2014 Phone 800 894 0412 Fax 888 723 4773 Web Page 54 of 58 www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 6 5 Alarm display The alarm display shows the status of several alarms Alarms with a grey background and an N A suffix do not apply for the switch type or for the current configuration of the switch N Tron NT24k N TRON Switch 7e 79 40 fh Fa als Power Supply 1 Error Power Supply 2 N A Boot Loader Version OK Port Utilization OK N Link N A N Ring N A Configuration Device Not Present emperature OK Low voltage on power input DC V2 Values ending with OK will be green with Error will be red and with N A will be gray Fields that do not apply to a specific switch model will be hidden The following table describes fields and values Field Values Description Power Supply 1 Power Supply 1 OK PSUI Power Supply I Error Power Supply 2 Power Supply 2 OK PSU2 Power Supply 2 Error Boot Loader Version Boot Loader Version OK Boot Loader Version Error Port Utilization Port Utilization OK Shows error if utilization Port Utilization Error limits on any port is exceeded Revision March 2014 Page 55 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation N Link N Li
24. FPS The frames per second rate of transmitted multicast frames RX Unicast FPS The frames per second rate of received unicast frames TX Unicast FPS The frames per second rate of transmitted unicast frames Port Errors The sum of alignment errors FCS errors SQE Test errors excessive collisions MAC transmit errors carrier sense errors frame too long and MAC receive errors Revision March 2014 Page 53 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k 6 4 Settings display N Tron Corporation The settings display allows some switch port related settings to be changed Use the buttons at the bottom to select a switch port and use the buttons at the left to select a port setting to change Use the wide up down buttons toward the bottom to select a value and the Enter button to accept the change Port C7 Settings Tron NT24k N TRON Switch 7e 79 40 Ao a El Speed Duplex Admin Enabled Auto Neqotiate 10 Half 10 F ull 100 Half 100 F ull 1000 F ull 100 F ull Yes EJ on The following table describes fields and values Field Value Description Speed Duplex 10 Full This configurable field displays the 100 Full current speed and mode of the port 1000 Full 10 Half 100 Half Unknown Admin Enabled Yes This configurable field displays the No existing status of the port whether it is Enabled
25. MR NTR p NTR NMR NTR OLNTRON_NT24k_v1_1 AOI for N TRON NT24k switch Copyrigh AOLNTRON_NT24k_v1_1 esses Switch_Inputs Switch_Output Switch_Parameters Input_Assembly Get_Message Get_Message_Extended Storage Set_Message SetData YQVvvnvvnvvv O 0 The following will appear OI NTRON NT24k v1 1 AOI for N TRON NT24k switch Copyrigh AOI NTRON NT24k vi1 1 Switch_Inputs Switch_Output Switch_Parameters Input_Assembly Get_Message Get_Message_Extended Storage Set_Message SetData YVVvnvnvvvvv fi 0 dE DODODCDODODODON Ms Add tag names for the various fields For example OI NTRON_NT24k_v1_1 AOI for N TRON NT24k switch Copyright N Tr AOL NTRON NT24k vi1 1 N228 EJ Switch Inputs N228 1 Data Switch Output N228 0 Data Switch Parameters N228Params Input Assembly NT24kinputAssembly Get_Message N228GetMsg Get Message Extended N228GetMsgExt Storage N228Storage Set_Message N228SetMsg J SetData N228SetData Revision March 2014 Page 17 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Right click on each new tag name and create each tag Note that the tags for Switch Inputs and Switch Outputs shown in the rectangle above were created when the Generic Ethernet Module was added For example Switch_Inputs N228 1 Data Switch Output N228 0 Data Swit
26. N tare add eden NETERA 23 To Troubleshooting O 23 3 6 Sample Proj l eraa EE EEEE E EAEE Ea E E aE 24 4 Rockwell RSLogix 5000 Tag reference cocononccccnnocccccononcnccononcncnnnnnncn nano nn nc naar nr cn naar nn cc nnnnnnncnnns 25 4 1 Generic assembly tags oriris iesi conca 25 4 2 NT24k assembly tags iiias aaee raa ii Di 27 4 3 System fault TAGS o anaia aT R Ad A 29 44GIP TAGS astra AAE 31 olden yobe Taia a REE id AR ae id ee 31 4 6 TCPIP ODjOCts i a e a RENET RA id de 31 4T Ethernet Link Object sis ans aR aeS da id a 32 4 8 N TRON Switch object coocooooccccnocononccccononcnnannoccnnnnnorcnn narran 34 5 Rockwell FactoryTalk Faceplate Installation Instructions arnrrrnronnrrnnronnrrrnronnrrnnnrnnrrrnrnn nn 37 5 1 Configuration of FactoryTalk View Faceplate Displays mrrrrrrnnnnnvvvvnnnnnvrrnnnnvrrnnnnrnrrnnen 37 5 2 Sample Projettuns ti na A i 48 6 Rockwell FactoryTalk Faceplate quick reference guide oooooccccnnoniccnnnocicccononncncnnancnncnnancnnnnno 49 6 71 roduc Uom aida 49 6 2 Fome GIS Plays a etterat 50 6 3 DIAgnostics dis Pla ci aii 52 64 Sennas display orie a A d cies 54 6 5 Alam displayr sautrssdtmaseksrsrtkeeee er A E A E 55 6 6 Enror MGSSages ici ere i 57 DUP 010 k ate NTE 58 SREICrENCES aai Ad 58 DO REVISIONS Lands 58 Revision March 2014 Page 2 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation
27. T Power Supply 1 BOOL 1 Indicates a low voltage on power supply 1 Power Supply 2 BOOL 1 Indicates a low voltage on power supply 2 NRing Full BOOL 1 Indicates that an N Ring connection is completely broken NRing Part Low BOOL 1 Indicates that an N Ring connection is only broken in one direction The lower N Ring port is not receiving self health frames around the N Ring but the higher N Ring port is NRing Part High BOOL 1 Indicates that an N Ring connection is only broken in one direction The higher N Ring port is not receiving self health frames around the N Ring but the lower N Ring port is NRing Multiple Man BOOL 1 Indicates that more than one N Ring agers Manager exists on an N Ring System BOOL 1 Indicates a system fault Config Device BOOL 1 Indicates a problem with the configuration device Revision March 2014 Page 29 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation NLink BOOL 1 Indicates that the N Link Master or Slave encountered a problem Boot Loader Version BOOL 1 Indicates a problem with the version of the boot loader firmware Port_Utilization BOOL 1 Indicates one or more ports have exceeded a high or low bandwidth utilization limit Temperature BOOL 1 Indicates the switch temperature has exceeded a high or low temperature limit Settings Fault BOOL 1 Indicates that a setting
28. THE INDUSTRIAL NETWORK COMPANY CIP User Manual amp Installation Guide NT24k Switch Family Si st CIP Common Industrial Protocol Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation N TRON CIP Manual Dit UC wien ani deni dine nls dail dna ail dane dane 3 2 CIP Components aana heen eerie SA a ad ae eee ee a se a Ge 3 2 1 Electronic Data Sheet EDS coin c 3 2 2 CIP Objets ised dain cd etcetera eda ten oa leech aan 3 2 2 1 1dentity Object sc nav cee meir dvedavaiv NAA A A E 4 2 2 2 TCP IP Interface Object c cceecccceeeetcccetdenceceedacceetdecceeensdheneesdecceeuedsneeeettecceeuetsneeeeeseaes 6 2 2 3 Ethernet Link Object voii aid 7 22 4 NETRON ObjECt uttatt hate na aars ae linia 9 2 3 CIP SEIVICES Lundin ltda diiniita 11 2 4 ACCESSING Data snaue diere edu diablita idiota dts debates 11 2 41 Explicit Messaging 2 ctricos a te Dietetica 11 2 4 2 NO COMECtONS attends ed detektere td 11 3 Rockwell RSLogix 5000 Add On Instruction Installation oonnrereronnrrnnnonnrrrnronnrrnnnrnnrrnnrennnn 13 3 1 Configuration of RSLogix project sise hariei anean a aE EAEE cnn nn rc rn anar rca 13 3 2 Input Assembly Parameters sic 22 iaae bades undere atrial labia 22 3 3 Switch_Parameters Parameter niian aaa aa a a aaa a eaa aaa aaa aaia aabot Aate 23 3 4 Explicit Messaging Options alare uniana eea aaee ar EAEN TAEAE Aa AAEREN AANEE
29. ailable Inbound packets that contain errors does not include In Discards In Unknown Protos UDINT 32 0 Not available Inbound packets with unknown protocol Out Octets UDINT 32 Octets sent on the interface Out Ucast Packets UDINT 32 Unicast packets sent on the interface Out Nucast Packets UDINT 32 Non unicast packets sent on the interface Out Discards UDINT 32 Outbound packets discarded Out Errors UDINT 32 0 Not available Outbound packets that contain errors 5 Media Counters STRUCT of Alignment Errors UDINT 32 Frames received that are not an integral number of octets in length FCS Errors UDINT 32 Frames received that do not pass the FCS check Single Collisions UDINT 32 Successfully transmitted frames which experienced exactly one collision Multiple Collisions UDINT 32 Successfully transmitted frames which experienced more than one collision SQE Test Errors UDINT 32 0 Not available Number of times SQE test error message is generated Deferred Transmissions UDINT 32 Frames for which first transmission attempt is delayed because the medium is busy Late Collisions UDINT 32 Number of times a collision is detected later than 512 bit times into the transmission of a packet Excessive Collisions UDINT 32 Frames for which transmission fails due to excessive collisions MAC Transmit Errors UDINT 32 0 Not available Frames for which transmission fails due to an internal MAC sub layer transmit error
30. ation is contained in the section for Add On Instruction installation Revision March 2014 Page 12 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 3 Rockwell RSLogix 5000 Add On Instruction Installation N TRON Switch RSLogix Add On Instructions AOI Installation Instructions Software installation prerequisites 1 RSLogix 5000 version 17 or later 2 N TRON switch with firmware version that includes CIP support Summary of steps 1 Import the Add On Instruction AOT 2 Add your N TRON switch to the I O Configuration tree 3 Add an instance of the AOI in your application 4 Create and configure tags for the AOI 3 1 Configuration of RSLogix project Extract all files from the zip file to your desktop or destination folder Open an RSLogix project Import the N TRON Add On Instruction AOI In the controller organizer window right click Add On Instructions folder select Import Add On Instruction and browse to the folder containing AOL NTRON L5X files Import an AOI for each switch type installed Unscheduled Programs Motion Groups E Ungrouped Axes New Add On Instruction Import Add On Instruction gg B Cut 5 6 Data Types Gi User Defin Ep Strings Gi Add On De E a Predefined E Copy Module Def 3 Trends E Paste 2 64 I O Configuration B 1756 Backplane 1
31. capacity Takes into account Resource the number of groups used per max groups and any Usage other possible resource limitations 0 100 10 IGMP Active UDINT 32 IP of the active IGMP querier Querier 11 CPU Usage USINT 8 Percent of usage 0 100 12 Class 1 UINT 16 Number of CIP EtherNet IP class 1 multicast Connections connections 13 Class 3 UINT 16 Number of CIP EtherNet IP class 3 unicast Revision March 2014 Page 9 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Connections connections 14 Temperature Set INT 16 Upper temperature C at which to declare an alarm Alarm Upper Threshold 15 Temperature Set INT 16 Lower temperature C at which to declare an alarm Alarm Lower Threshold 16 Contact Status BYTE 8 2 Bits per contact 00 Not Present 01 Open 10 Closed 17 Temperature_C INT 16 Temperature in degrees C 0x7FFF Not Supported on device 18 Temperature F INT 16 Temperature in degrees F 0x7FFF Not Supported on device 19 Reset MIB Set LWORD 64 Reset port MIB counters 1 bit per port to reset Counts 20 Device MAC ARRAY of 6 MAC address of device Address USINTs 8 21 Device Role UDINT 32 Bit mask of device roles Bits 0 N Ring Manager 1 N Ring Member 2 N Ring AutoDetect 3 N Link Master 4 N Link Slave 5 N Link
32. ch Parameters Input Assembly N228InputAss New N228Params Ctrl Ww Get_Message N228G a Get Message Extended N228Gett de Cut Instruction Ctrl X Storage N2285 Copy Instruction Ctrl C Set_Message N2288 Ctra SetData N2285 Paste Delete Instruction Del Add Ladder Element Alt Ins Edit Main Operand Description Ctrl D Save Instruction Defaults Click the button to the right of the Get_Message tag and configure as shown Message Configuration N228GetMsg Configuration Communication Tag Message Type y Service Custom vi Source Element i x Type Source Length 0 2 Bytes r Service Coie fi Hex Class fi HEX Destination N2285toragel0 y Instance 1 Attribute f1 Hex z New Tag O Enable Enable Waiting D Start O Done Done Lenath O D Error Code Extended Error Code l Timed Out Error Path Error Text Cancel Help Revision March 2014 Page 18 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Message Configuration N228GetMsg Configuration Communication Tag Path IN228 Browse N228 r Communication Method je CIP DH Channel v Destination Lint fo 4 e OP with Source Link fo Destination Node fo 4 Octal Source ID Connected I Cache Connections e I Co e O Enable Enable Waiting D Start O Done Done Length 0 D Err
33. d 0 disabled Interface_Label STRING Label like A5 Interface_Description STRING Something like Port 1 10 100 Mbit TX Port 15 100 MBit FX Interface_Utilization SINT Percentage of entire interface bandwidth being used 0 100 Utilization Alarm Upper Thres SINT Upper percentage at which to declare a hold utilization alarm 0 100 Utilization Alarm Lower Thre SINT Lower percentage at which to declare a shold utilization alarm 0 100 Broadcast Limit SINT Broadcast limiting percentage 0 100 BPCL TX Unicast Packet Rate DINT Number of TX unicast packets per second RX Unicast Packet Rate DINT Number of RX unicast packets per second TX Multicast Packet Rate DINT Number of TX multicast packets per second RX Multicast Packet Rate DINT Number of RX multicast packets per second TX Broadcast Packet Rate DINT Number of TX broadcast packets per second RX Broadcast Packet Rate DINT Number of RX broadcast packets per second TX Multicast Packets DINT Total number of TX multicast packets RX Multicast Packets DINT Total number of RX multicast packets TX Broadcast Packets DINT Total number of TX broadcast packets RX Broadcast Packets DINT Total number of RX broadcast packets Port Role DINT Bit 0 RSTP 1 N Ring 2 N Link Control 3 N Link Partner 4 N Link Coupler 4 8 N TRON Switch object Data Type UDT NTRON CIP Switch NT24k v1 Name Data Type Description Device Uptime DINT Number of
34. d lion net Email info the red lion net CIP Manual NT24k 2 2 3 Ethernet Link Object N Tron Corporation The Ethernet Link object class Class code 0xF6 and instance attributes are implemented as defined by CIP Vol 2 5 4 2 There is one instance of this object per switch port where instance I port 1 instance 2 port 2 etc As per the CIP specification the get all service code 0x01 will get all attributes excluding vendor extensions Service code 0x32 will get all attributes including the N TRON vendor extensions The following table summarizes the attributes in the Ethernet Link object Id Name Set Format Description 1 Interface Speed UDINT 32 Interface speed currently in use Speed in Mbps e g 0 10 100 1000 etc 2 Interface Flags DWORD 32 Interface status flags Bit map of interface flags See section 5 4 3 2 1 Includes Link status duplex mode auto negotiation status etc 3 Physical Address ARRAY of6 MAC address of switch port Base USINTs 8 MAC plus port number 4 Interface Counters STRUCT of In Octets UDINT 32 Octets received on the interface In Ucast Packets UDINT 32 Unicast packets received on the interface In Nucast Packets UDINT 32 Non unicast packets received on the interface In Discards UDINT 32 Inbound packets received on the interface but discarded In Errors UDINT 32 0 Not av
35. es that depend on the switch configuration Fields that do not apply to a specific switch model will be hidden The following table describes fields and values Field Values Description IP Address Like 192 168 1 201 Switch IP address Subnet Mask Like 255 255 255 0 Switch subnet mask MAC Address Like 00 07 AF FE 8F A0 MAC address of switch Software Version Like 3 0 2 Software version of switch Power Supply PSUI PSU1 Power Supply 1 PSU2 PSU2 Power Supply 2 PSU1 and PSU2 Unknown AC DC Power Contact Status Not Supported The status of the contact on the Revision March 2014 Page 50 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Open Closed switch N Ring Status Fault Partial Low Partial High Multiple Managers OK N A if N Ring auto member or N Ring disabled Unknown if N Ring member The N Ring status if the switch is configured as an N Ring manager IGMP Querier Disabled Active Manual Active Auto Backup Auto Unknown Internet Group Management Protocol Querier status IGMP Utilization 0 100 percent Internet Group Management Protocol Utilization Config Device Not Supported Not Present Present Unknown This field is displayed for switches that support a configuration device Role N Ring Manager N Ring Member N Ring Au
36. f ME click the Copy from Design to Runtime button Revision March 2014 Page 38 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 2 Import graphics pe ILANUP HMI Tags g Tags Graphics Displays New Add Component Into Application mage a Param Import and Export EE Local Messages Alarms Bl Alarm Setup 3 Information ES Information Setup BA Informatinn Messanes Graphics Import Export Wizard Operation Type Select the operation to perform Export graphic information from displays ort graphic information into displays De pr Graphics Import Export Wizard Backup Do you want to backup the displays that will be modified by the import C Yes Graphics Import Export Wizard Import File Type Select the type of file to import Single display import file lt Back ne Cancel Help Revision March 2014 Page 39 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Graphics Import Export Wizard Multiple Import File Select the multiple display batch import file C Temp FactoryT alk_View_ME Digplay_export Install B atchl mport_Global_ NTRON xml When importing Create new objects on the display Update e
37. f Object with Input Focus Startup AAA gt V Disable Highlight When Object has Focus NTRON Open 228 E PE EEE NE Ulla aE Highlight Color Shutdown es Cancel Apply Help Revision March 2014 Page 43 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 8 Click the General tab and change Display Type and Size Here is the ME form Display Settings General Behavior Display Type Size C Use Current Size Specify Size in Pixels Cannot Be Replaced Width 364 Height 456 Display Number Position x jo E o Security Code v I Title Bar Background Color Lp Insert Variable Disable Initial Input Focus Maximum Tag Update Rate 1 v seconds Revision March 2014 Page 44 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Here is the SE form Display Settings Properties Behavior m Display Type Size C Replace C Use Current Size C Overlay Specify Size in Pixels Width 364 Height 456 Allow Multiple Running Copies m Resize m Cache After Displaying Allow Display to be Resized oN ue When Resized es c ic i Pan Scale V Title Bar Heen F C Use Current Position Specify Position in Pixels Insert Variable x lo Y lo Syste
38. info the red lion net CIP Manual NT24k N Tron Corporation 4 Rockwell RSLogix 5000 Tag reference The assembly data received from an N TRON switch can be viewed with generic tags or switch specific tags Generic tags are defined by the data type UDT_NTRON Switch In NT24k v0 Switch specific tags are defined by a switch specific data type Switch Data Type NT24k UDT NTRON Switch NT24k In vl NT24k DR16 UDT NTRON Switch NT24k DR16 In vl NT24k DR24 UDT NTRON Switch NT24k DR24 In vl Here are some of the tag descriptions 4 1 Generic assembly tags Data Type UDT NTRON Switch In NT24k v0 Generic view of assembly data received from an N TRON Switch Name Data Type Description System Faults UDT NT Status of various system faults RON Syst em Faults NT24k v 0 Admin Status DINT Admin Status of first 32 ports Also available as port specific tags Admin Status I Admin Status 2 Admin Status 3 BOOL 1 enabled 0 disabled Admin Status 30 Admin Status 31 Admin Status 32 Admin Status2 DINT Admin Status of second 32 ports Also available as port specific tags Admin Status 33 Admin Status 34 Ann Sen 55 BOOL 1 enabled 0 disabled Revision March 2014 Page 25 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Admin Status 62 Admin S
39. ion The Faceplates consists of several displays Home Diagnostics Settings and Alarm Click the buttons at the top of the screen to navigate between the displays The button is used to toggle the display of help text and the X button is used to exit the Faceplates N Tron NT24k N TRON Switch 7e 79 40 A 2 x The caption at the top includes the switch product name and the user assigned switch name separated by a colon N IRON THE INDUSTRIAL NETWORK COMPANY N TRON Switch Faceplate NT24k Demo version 1 2 September 2013 Exit Revision March 2014 Page 49 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 6 2 Home display This home display shows general switch information The trend shows CPU utilization N Tron NT24k N TRON Switch 7e 79 40 fh JR ES IP Address 192 168 1 241 Subnet Mask 255 255 252 0 MAC Address 00 07 AF 7E 79 40 Software Version 1 4 4 next Power Supply PSU1 Contact Status Open N Ring Status NA IGMP Querier Backup Auto IGMP Utilization 1 Role N Ring AutoMember Not Present Config Device CPU Utilization 17 Temperature 42 C Wednesday October 02 2013 AAA 16 10 19 56 4M 10 20 56 10 21 56 AM Al Active O Inactive HE Disabled M Error HB Fault Some fields show simple values such as IP Address Others such as Device Role show valu
40. ion March 2014 Page 22 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 3 3 Switch Parameters Parameter The AOI requests additional information from the switch as needed by a faceplate display and when started This includes the CIP Identity object the CIP TCP IP object an instance of the CIP Ethernet Link object and the NTRON Switch object The RSLogix 5000 screenshot below shows a top level view of some of the AOI Switch Parameters structure N228params UDT NTRON Switch Common v 0 N228params Generic_Inputs UDT NTRON Switch In v0 N228params Dutput DINT N228params Identity UDT NTRON CIP Identity v N228params TCPIP UDT NTRON CIP TCPIP Interface v0 N228params Switch UDT NTRON CIP Switch v0 N228params Ethernet Link UDT NTRON CIP Ethernet Link v0 64 N228params Data UDT NTRON CIP DATA v0 N228params Control UDT NTRON CIP Control v0 N228Params Generic Inputs is a generic view of the assembly data from a switch 3 4 Explicit Messaging Options To direct the AOI to gather this information via explicit messaging for other purposes example not using faceplates use the following members of the N228Params Control tag Name Data Type Description Selected Port INT Use this member to read Ethernet Link object for one port To read more than one port use Read Port Mask Set by the faceplate Port
41. m Menu Minimize Button Security Code f vi IT Maximize Butto I Size to Main Window at Runtime Background Color MV Show Last Acquired Value Maximum Tag Update Rate 1 y seconds Cancel Set as Default Help On the display where you wish to show the faceplate create a Goto Display button Create a parameter file that will be associated with the button Ei NTRON demo NTRON demo Parameters Parameter File Created 2009 07 02 Parameter files are used with graphic displays to specify the tags a display I uses at runtime You assign parameter files to displays in the Startup editor and in the dialog box for configuring goto display buttons and display list selectors I Syntax l replacement tagname Example l 23 A_COLOR I 23 in any expression in a graphic would be replaced by the tag A COLOR 1 PLC N228Params 2 PLC N228Params Control HMI 0 3 PLC Revision March 2014 Page 45 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Substitute your shortcut for PLC and the name of your Switch Parameters for N228Params in the parameter file Assign a display and parameter file to the Goto Display button Here is the ME form Goto Display Button Properties General Label Common Appearance Border style Border width Raised M ja IV Border uses back color Ml Back color Back s
42. nk OK N Link Error N Link N A Shows N A if not configured for N Link N Ring N Ring Error Redundancy Lost N Ring Error Partial Low N Ring Error Partial High N Ring Error Multiple Managers N Ring Error Redundancy Lost Mult Mgrs N Ring Error Partial Low Mult Mgrs N Ring Error Partial High Mult Mgrs N Ring OK N Ring N A Shows N A if not configured as an N Ring manager Configuration Device Configuration Device OK Configuration Device Error Configuration Device N A This field is displayed if the switch supports a configuration device Temperature Temperature OK Temperature Error Temperature N A This field is displayed if the switch supports a temperature sensor The system fault string is shown at the bottom of the display Revision March 2014 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net Page 56 of 58 CIP Manual NT24k N Tron Corporation 6 6 Error Messages There are a few messages that appear on the faceplate near the top when certain errors are detected NTRON Buttons Pane INT 24k MEM GL 0 1X The table below describes the messages Background Message Description Color Red Controller fault The controller is in the Faulted mode Red Controller not running The controller is not in the Run or Remote Run mode Red Stale Data The cont
43. ntrol flags Path Size INT Size of Path Object Path I INT Logical segments identifying the physical Revision March 2014 Page 31 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation link object Object Path 2 INT Logical segments identifying the physical link object IP Address INT The device s IP address Network Mask INT The device s network mask Gateway Address Name Server I INT Primary name server Name Server 2 D D DINT Default gateway address D D INT Secondary name server Domain Name STRING Default domain name Host Name STRING Host name 4 7 Ethernet Link object Data Type UDT NTRON CIP Ethernet Link v0 Name Data Type Description Interface Speed DINT Interface speed currently in use Speed in Mbps e g 0 10 100 1000 etc Interface Flags UDT NTR Interface status flags ON CIP I nterface Fl ags v0 Physical Address SINT 6 MAC layer address InOctets DINT Octets received on the interface InUcastPackets DINT Unicast packets received on the interface InNucastPackets DINT Non unicast packets received on the interface InDiscards DINT Inbound packets received on the interface but discarded InErrors DINT Inbound packets that contain errors does not include In Discards
44. nual NT24k MM Select Module Description 1769 L23E QBFC1 Ethernet Po 1769 L32E Ethernet Port 1769 L35E Ethernet Port 1788 EN2DN A 1788 ENBT A 1788 EWEB A 1794 AENT A 1794 AENT B DrivelogixS730 Ethernet Port ETHERNET BRIDGE ETHERNET MODULE male melk Van de AY N Tron Corporation Vendor 10 100 Mbps Ethernet Port on CompactLogix53 10 100 Mbps Ethernet Port on CompactLogix53 10 100 Mbps Ethernet Port on CompactLogix53 1788 Ethernet to DeviceNet Linking Device 1788 10 100 Mbps Ethernet Bridge Twisted Pai 1788 10 100 Mbps Ethernet Bridge w Enhanced 1794 10 100 Mbps Ethernet Adapter Twisted P 1794 10 100 Mbps Ethernet Adapter Twisted P 10 100 Mbps Ethernet Port on DriveLogix5730 Generic EtherNet IP CIP Bridge Generic Ethernet Module Mell a mi PANN Mad chi r AY Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradle Allen Bradlg Mi A lle Eind Add Favorite By Category Favorites met eo 7 Configure the module as shown Use the proper IP address and connection parameters for your installation E Module Properties Report enet ETHERNET MODULE 1 1 General Connection Module Info Type ETHERNET MODULE Generic Ethernet Module Vendor Allen Bradley enet N228 Parent Connection Parameters Assembly Instance Input 102 26
45. or Code Extended Error Code l Timed Out Error Path Error Text Cancel Apply Help Click the button to the right of the Get Message Extended tag and configure as shown Message Configuration N228GetMsgExt Configuration Communication Tag Message Type CIP Generic v Service Custom y Source Element v Type Source Length lo Bytes Service cod 32 Hex Class fi Hes Destination N2285toragel y Instance 1 Attribute 1 Hex 3 New Tag Enable Enable Waiting O Start Done Done Length 0 D Error Code Extended Error Code I Timed Out Error Path Error Text Cancel Apply Help Revision March 2014 Page 19 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Message Configuration N228GetMsgExt Configuration Communication Tag Path IN228 Browse N228 r Communication Method CIP DH Channel Destination Link y CIP with Source Link fo Destination Node Source ID l Connected V Cache Connections e D Enable Enable Waiting D Start D Done Done Length 0 D Error Code Extended Error Code I Timed Out Error Path Error Text Cancel Help Click the button to the right of the Set_ Message tag and configure as shown Message Configuration N228SetMsg Configuration Communication Tag
46. pePlus Setup RecipePlus Editor ML RSLinx Enterprise alfermecsinsis 7 13 System In the screenshot following the shortcut is named PLC Revision March 2014 Page 37 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Communication Setup RNA SLocal NTRON_demo RSLinx Enterprise Device Shortcuts Design Local Runtime Target Add Remove er Copy from Design to Runtime 4 RSLinx Enterprise 119 ENGINEERING amp 1789 417 Backplane g EtherNet Ethernet f 192 168 1 40 1756 ENBT A 1756 ENBT A 1756 A4 A 1756 44 4 E j 0 1756 L62 ControlLogix Engineering 4 5 DF1P2P DF1 Point to Point 2 1756 IB16D 4 1756 IB16D A DCIN DIAG RSLinx Enterprise 3 1756 0B16D A 1756 OB16D A DCOUT DIAG 68 1 41 Ethernet Bridge 1769 L35E Ethernet Bridge 1769 L35E bmpactLogix System CompactLogix System 3 Design Local path edited 0 1769 L35E A CompactLogix Engineering Old 3 Local Adapter VA1769 4 New 1756 44 A DemoZ2 68 1 44 N TRON 716TX 1 68 1 45 N TRON 7018FX2 2 Press Yes to apply changes Press No to discard changes P9 1 46 N TRON 708TX 5 68 1 71 N TRON 708TX 8 No 68 1 81 N TRON 708FX2 2 68 1 86 N TRON 708FX2 168 1 87 N TRON 708TX 6 Mode Online Not Browsing You ve made the following changes to the shortcut PLC Click the Yes button and i
47. roller has stopped receiving data updates from the switch Orange CIP version on switch is not The CIP version on the switch is not supported supported by the add on instruction on the controller Orange Version of AOI is The add on instruction on the controller incompatible does not support the switch Yellow Configuration Error The product code for the switch is invalid or has not been read Controller refers to the third replacement text example 3 PLC of the parameter file associated with the display 2 Switch refers to the switch associated with the first replacement text example 1 PLC N228Params of the parameter file associated with the display Revision March 2014 Page 57 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k 7 Support Contact Information 8 References N Tron Corporation 1 The CIP Networks Library Volume 1 Common Industrial Protocol CIP Edition 3 5 Publication Number PUB00001 Open DeviceNet Vendor Association Inc 4220 Varsity Drive Suite A Ann Arbor MI 48108 5006 USA 2 The CIP Networks Library Volume 2 EtherNet IP Adaptation of CIP Edition 1 6 Publication Number PUB00002 Open DeviceNet Vendor Association Inc 4220 Varsity Drive Suite A Ann Arbor MI 48108 5006 USA 9 Revisions Revision Description July 2013 Initial version with support for switches in
48. s misconfiguration needs to be resolved Revision March 2014 Page 30 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 4 4 CIP Tags There are tags for each CIP object The tags correspond to the object s attributes gt Identity object gt TCP IP Interface object gt Ethernet Link object gt N TRON switch object 4 5 Identity object Data Type UDT NTRON CIP Identity v0 Name Data Type Description Vendor ID INT ODVA Vendor ID N Tron 1006 Device Type INT 0x0C Communications Adapter Product_Code INT NT24k 24001 NT24k DR16 24002 NT24k DR24 24003 Major_Revision SINT Major revision of the item the Identity Object represents Minor Revision SINT Minor revision of the item the Identity Object represents Status INT Summary status of device Serial_ Number DINT Serial number of device Product Name STRING Human readable identification Switch model number Ex N TRON NT24k Assigned Name UDT NTRO User assigned switch name N String1024 Geographic Location UDT NTRO This is the user assigned switch location N String1024 4 6 TCPIP object Data Type UDT NTRON CIP TCPIP Interface vO Data Name Type Description Status DINT Interface status Configuration Capability DINT Interface capability flags Configuration Control DINT Interface co
49. tatus 63 Admin Status 64 Link Status DINT Link Status of first 32 ports Also available as port specific tags Link Status I Link Status 2 Link Status 3 BOOL l active 0 inactive Link Status 30 Link Status 31 Link Status 32 Link Status2 DINT Link Status of second 32 ports Also available as port specific tags Link Status 33 Link Status 34 Link Status 35 BOOL 1 active 0 inactive Link Status 62 Link Status 63 Link Status 64 Utilization Alarm DINT Bandwidth utilization alarms for first 32 ports Also available as port specific tags Utilization Alarm 1 Utilization Alarm 2 Utilization Alarm 3 BOOL 1 bandwidth utilization exceeds a high or low limit O bandwidth utilization within limits Utilization Alarm 30 Utilization Alarm 31 Utilization Alarm 32 Utilization Alarm2 DINT Bandwidth utilization alarms for second 32 ports Also available as port specific tags Utilization Alarm 33 1 bandwidth utilization exceeds a high or low Utilization Al 34 limit 0 bandwidth utilization within limits ilization Alarm BOOL Revision March 2014 Page 26 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Utilization Alarm 35 Utilization Alarm 62 Utilization Alarm 63 Utilization Alarm 64
50. the NT24k family August 23 2013 Added missing documentation for the Power Configuration attribute of the NTron object October 2013 Added faceplate installation instructions and quick reference guide March 2014 Added a description of the faceplate error messages Revision March 2014 Page 58 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net
51. toMember N Link Master N Ring Mem N Link Master N Ring Auto N Link Master N Link Slave N Ring Mem N Link Slave N Ring Auto N Link Slave N Link Coupler N Ring Mem N Link Coupler N Ring Auto N Link Coupler Unknown The role of the switch which is based on the switch configuration CPU Utilization 0 100 percent CPU utilization percentage CPU Trend 0 100 percent Trend of CPU utilization On the switch image the color of each port changes based on the port state Port Color Inactive Port State The port is active The port is inactive The port is administratively disabled A port utilization limit high or low has been exceeded The LED at the top of the switch graphic will be green if there are no faults red if a fault has occurred You can view faults on the alarms display Revision March 2014 Page 51 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 6 3 Diagnostics display The diagnostics display shows information for a selected switch port Use the buttons at the bottom to select a switch port and use the buttons at the left to select a port variable to trend The highlighted variable is trended at the bottom N Tron NT24k N TRON Switch 7e 79 40 A ml al al al a Port C7 Diagnostics Link Up Yes Speed Duplex 100 Full Admin Enabled Yes
52. tus DINT Link Status of first 32 ports Also available as port specific tags Link Status Al Link Status A8 Link Status Bl BOYLE 1 active 0 inactive Link Status B8 Link Status C1 Link Status C8 Utilization Alarm DINT Bandwidth utilization alarms for first 32 ports Also available as port specific tags Utilization Alarm Al Utilization Alarm A8 Utilization Alarm B1 1 bandwidth utilization exceeds a high or BOOL low limit 0 bandwidth utilization within Utilization Alarm B8 limits Utilization Alarm C1 Utilization Alarm C8 Class Connections INT Number of CIP EtherNet IP class I multicast connections Class3 Connections INT Number of CIP EtherNet IP class 3 unicast connections Temperature C INT Temperature in degrees Celsius 0x7FFF Revision March 2014 Page 28 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Not supported on device Temperature F INT Temperature in degrees Fahrenheit Ox7FFF Not supported on device CPU_ Utilization SINT Percent of CPU usage 0 100 Contact_ Status SINT 2 Bits per contact 00 Not Present 01 Open 10 Closed Utilization A1 Utilization_A8 Utilization B1 SINT bandwidth utilization in percent Utilization B8 Utilization C1 Utilization C8 4 3 System fault tags Data Name Type Description Faults DIN
53. tyle Pattern style IM Border color Solid Y None y C Pattern color BB Highlight color Shape I Blink Rectangle vi Display settings Display NTRON NT24k Dis Parameter file NTRON_demo a Parameter list El Display position Top position Left position j i Here is the SE form Button Properties General Action Up Appearance Down Appearance Common Action Run command v Press action Display NTRON NT24k Display PNTRON dem El You can also display an image of an NTRON switch using the global object NTRON NT24k graphic When used define Global Object Parameter 1 as follows Global Object Parameter Values Name Value Tag Description 1 PLC NZ28Params Path to Switch Parameters like PLC IN228Params Revision March 2014 Page 46 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation The NTRON NT24k graphic global object is a composite of several N TRON switches Due to the number of switches and the tags used for each switch you may run into the limit for maximum tags allowed on a display To work around this limitation use individual global objects for each switch These are imported by using the BatchImport Global NTRON_Switches xml import file The global object names contain the switch name such as NTRON NT24k DR16 Setup Global Object Parameter
54. ummarizes the attributes in the TCP IP Interface object Id Name Set Format Description I Status DWORD Interface status 32 0 interface configuration attrib not configured 1 interface configuration attrib is valid 2 Configuration DWORD Interface capability flags Bits Capability 32 0 BOOTP client capable 1 DNS client capable 2 DHCP client capable 3 DHCP DNS update capable 4 Configuration is settable 5 Through bit 31 reserved 3 Configuration Set DWORD Interface control flags Control 32 Bits 0 3 0 use interface configuration previously stored 1 get interface configuration via BOOTP 2 get interface configuration via DHCP 3 through 15 reserved Bit 4 1 device shall resolve host names by querying a DNS server 4 Physical Link STRUCT Object of Path Size UINT 16 Size of Path Path Padded Logical segments identifying the EPATH physical link object 5 Interface STRUCT Configuration of IP Address Set UDINT 32 The device s IP address Network Mask Set UDINT 32 The device s network mask Gateway Set UDINT 32 Default gateway address Address Name Server Set UDINT 32 Primary name server Name Server 2 Set UDINT 32 Secondary name server Domain Name Set STRING Default domain name 6 Host Name STRING Host name Revision March 2014 Page 6 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the re
55. uration is in bits 0 3 and Power supply 2 configuration is in bits 4 7 Revision March 2014 Page 36 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation 5 Rockwell FactoryTalk Faceplate Installation Instructions N TRON 700 Series Switch FactoryTalk View ME SE Faceplate Displays Software installation prerequisites 1 FactoryTalk View Studio ME SE version 5 or later 2 N TRON switch with firmware version that includes CIP support Summary of Faceplate installation steps 1 Create shortcut to PLC 2 Add global objects to your project 3 Add local messages 4 Add images 5 Import HMI tags 6 Create faceplate display 7 Configure display startup macro 8 Configure display parameter file 9 Optionally add composite switch image to display 10 Optionally add specific switch image to display In the instructions below ME refers to FactoryTalk View ME Machine Edition and SE refers to FactoryTalk View SE Site Edition 5 1 Configuration of FactoryTalk View Faceplate Displays Extract all files from the zip file to your desktop or some other folder Start with an existing FactoryTalk View ME SE application 1 Configure a shortcut to the PLC that is running the NTRON AOI Double click Communications Setup HEY TODA Messayos Logic and Control Macros Data Log Data Log Models SQ RecipePlus Reci
56. xisting objects on the display Whether you create new objects or update existing objects on the display can also be specified within the multiple displays batch import file and will override the setting defined above Cancel Help For SE use the FactoryTalk View SE folder in the above dialog These global objects should appear in the Explorer window fa Global Objects NTRON_NT24k_Display NTRON_NT24k_oraphic f Libraries 3 Import local messages 7 Global Objects Libraries bag Images Parameters a H E Alarms New a Alar Add Component Into Application Information ES Information Setup Information Messages A Logic and Control a Macros a n Revision March 2014 Page 40 of 58 Phone 800 894 0412 Fax 888 723 4773 Web www the red lion net Email info the red lion net CIP Manual NT24k N Tron Corporation Select the folder FactoryTalk_View_ME Display_export Install local containing the local message files loc Import all NTRON loc files The Explorer window should show these files pr Local Messages NTRON Confiq Device States NTRON Contact States NTRON Device Role NTRON General NTRON Help NTRON IGMP Querier States NTRON Nrinq States NTRON NT24k Help NTRON Port Role NTRON Power States NTRON Speed Duplex SF Alarms 4 Import images Sy HMI Tags gt Tags Graphics tc Displays Global Objects
Download Pdf Manuals
Related Search
Related Contents
Manual usuario CMC Oct2009 User Manual - Laboratory ovens 10. NT 65/2 Eco ME - Alfred Kärcher Gmbh and Company 『 レビス ® インスリン‐ラット T 』取扱説明書 Bionaire BCM630CN05EFM1 Humidifier User Manual MANUALE D`USO - Bayer Diabetes Care DeviceNet™ With ADR Option Kit CM012 Manual del usuario Manual de Instalação, Operação e Manutenção Copyright © All rights reserved.