POWERSTUDIO USER MANUAL 1 / 4

image

Contents

1. 35 a control SWC 36 3 2 18 do I add animation to the SCADA seen eene eene eese nenne rrr nnne enne nnns 36 3 2 19 How can I simulate level 37 3 2 20 can I change the properties of control in accordance with a condition 37 2 2 2 ow can 1 know the status Of a device E NAE ENE 3 3 2 22 can I display documents from SCADA screen 3 4 User Manual PowerStudio mi CIRCUTOR 3 2 25 can I obtain an event according to the status of a device icccccccccssesscccccccecennssseeceeeeeeaaseeseeees 3 3 2 24 can I produce sounds in response tO an 3 3 2 25 do I show documents in response to an 39 3 2 26 can I communicate with a TCP2RS converter by way of a router esses 39 3 2 27 There are screens on which I cannot see the text of the controls properly or they are truncated II EVER ATUM 39 3 2 28 When viewing a graph and selecting the tooltip the graph disappears How can I solve this 40 3 2 29 I cannot connect with the engine or some TCP IP devices has errors On the Java console I see java net BindException Address already in use connect How can I solve this eese 40 3 2 80 Wh
2. eese 30 3 2 4 The Applet does not display the texts properly What could be happening seus 30 2 2 9 The values display is what expected What could be happening sess 30 3 2 6 An event is not behaving as expected What could be amp 31 22 7 I can t paint the graph correctly What could be happening esses 31 3 2 8 The Paint Pot is not working correctly What could be happening esses 31 3 2 9 The software is not sending e mails What might be happening eese 24 3 2 10 I launch external applications from 32 3 2 11 How can I see the applet from a machine which is not running 32 3 2 12 Can I directly connect with a known IP when I execute the Applet What happens if there s authentication What parameters can I use to configure the Applet application launch by 3 2 13 I am making first screen or report and I cannot add a background image or a still picture UTOR mi m 33 Pada WACO CO b RC 33 3 2 15 I would like to export the report data in order to process it later How can I do it 33 3 2 16 Itried to make a table with the client application and I get the Message Table too Big What Wo ENTE I
3. 1 VI1 221 CVM 1 VI1 224 Another option would be to draw the level control at the bottom of the SCADA screen and use various paint pot controls to paint the desired zone Thus we could draw on the screen background something like the following The inner part although it seems all the same color white it is not and is divided into grids with different whites indistinguishable one from the other and by the human eye for example it is impossible to distinguish between white RGB 255 255 255 and white RGB 254 255 255 Then we place the paint pot on each table with the desired condition and tolerance 0 to prevent painting adjacent tables which are very similar in color With this the result is a progress bar or control level which can be configured as desired 3 2 20 How can change the properties of control in accordance with a condition The properties of control cannot be changed in accordance with a condition However we can simulate the change of these properties using a conditional control Thus for example if we wish to change the color of a text in accordance with a condition we add a conditional control with two text type controls which are exactly the same but of a different color and specify which conditions need to be fulfilled for each one to be shown Likewise we can also change the orientation font size etc We can also make a control be an image or a text in accord
4. 15 1 3 3 Export the application 10 the 16 1 3 4 View the application in the eene enne nn nnn nnne nennen eene 18 Zo SYSTEM FCR Ear aii 21 s 22 ERY E ee 22 Sua CO 22 3 1 2 services user devicelInfo xml id device eee eese ee eee eee 27 3 1 3 services user varInfo xml var device variable id device eese 23 3 1 4 services user values xml var device variable id device esses 24 Sul services user forceVariables xml id 25 3 1 6 services user records xml beginz endz varz period 900 essen 25 dud eene nennen nnn nnns 27 3 1 8 28 S re PRIUS 30 3 2 1 Some equipment is not communicating What could be amp 30 2 2 2 A TCP2RS converter does not communicate What could be 30 2 2 3 I cannot see the applet What could be happening
5. dateTime fields lt field gt fieldComplex fieldComplex fieldARM lt fieldARM fieldFO fieldFO fieldEVQ fieldEVQ lt recerd gt lt recordGroup gt Where User Manual 25 CIRCUTOR PowerStudio recordGroup Main field which will identify the XML as a response to the variable register request e period Register period Will report on time elapsed between records e record Will Identify each of the records dateTime Date and time of the sample field Standard value register fieldComplex Complex value register fieldARM Harmonic value register fieldFO Waveform value record fieldEVQ EVQ event register Here are the different types of values that can be returned by this request e Standard value registers voltages currents power energy etc lt field gt lt id gt uw lt id gt lt value gt value Field Variable identifier device variable value Value e Complex value register PLT etc lt fieldComplex gt lt id gt uo lt id gt lt value gt value Cctlags flags lt fieldComplex Variable identifier device variable value Value flags Additional information from the variable formed by the union of one or more of the following values 0x0000 gt The PLT is correct 0 0001 gt The PLT calculation has been done with fewer samples than expected 0 0002 gt The
6. After having updated the configuration if there is an old version installed and the installation has been completed a dialogue will appear reporting that the installation was correctly completed 12 User Manual PowerStudio CIRCUTOR Choose Destination Location Select folder where setup will install files InstallShield Wizard Complete the wizard The InstallShield Wizard has successfully installed Cireutor PowerStudio Scada Click Finish to exit installs jd _ lt 8 me Bp Installation complete When the client is installed a default application will be created called Local which will be the active installation the first time the client is run If the PowerStudio installation is done on top of a previous version the entire configuration will become a part of the Local application User Manual 13 CIRCUTOR PowerStudio 1 3 TYPICAL APPLICATION Below we show the steps required to create a typical application configure the communications engine create the application from the editor export the application and view the application from the client 1 3 4 Configure the communications engine For the application to operate properly the first step will be the configuration of the communications engine When the communications engine is installed the runtime PSEngineManager application is copied to the same directory and with this application can configure the engine
7. B 1 21 34 CVMID 1 0 cvm 96 10 96 CVM 96 Ethernet 09 96 B cvm cio 08 cvMc10 M cvv 06 8 CVM MINI 23 CVMMINI CVM MINI Ethernet 41 CVM MINIEthernet CVM NET 22 CVMNET E CVM NET4 28_CVMNET4MC 29 CVMNETAMC cvM NRG96 07 CVMNRG96 f DH 96 11 DH96CPM 12 DH96AC 13 DH96CT 14 DH96CT EDMk 24 EDMk 8 EDS EDS Lab e EDS 3G EDs 3G Lab EDS 3G Embedded cvm 144 LM25 M A Server Ok LiveTest labtest3 8083 User Manual Reports 24s E Tabe Events a Properties gt Print Device CVM C10 Name 08 CVMCI1O Description Peripheral number 8 Communication Yes History Yes View device status by connection 19 CIRCUTOR Wy 08 CVMCIO PowerStudio Scada Options Views General Previous o9 Next v Devices screens Reports 24s FE Tabe MIS a Properties gt Print V tex 08_CVMC10 PowerStudio 11 14 13 12 15 25 PM nstantaneous 4 Maximums 3 minimums Energy ur Voltage harmonics T Current harmonics L1 L2 L3 L1 i L3 1 r Voltage r Consumed power Active KW 48 0 49 0 49 0 146 0 Phase neutral V 6 450 0 6 490 0 6 500 0 Capacitive kvarC 10 0 10 0 10 0 30 0 Inductive kvarL 0 0 0 0 0 0 0 0 Phase phase V 0 0 0 0 0 0 Apparent kVA 59 0 59 0 60 0 179 0 Power fac
8. Normally this amount of memory allocated by default is sufficient for running the program But perhaps for very large tables this memory is insufficient For these cases it is possible to run the client application forcing the virtual machine to assign more memory to the program This is accomplished by running the program from the command line with a parameter indicating the maximum and minimum memory available for the program java Xm256m Xmx1024m jar AppletScada jar As you can see the parameters Xm and Xmx allocate a minimum and a maximum quantity to the program User Manual 35 CIRCUTOR PowerStudio 3 2 17 How can simulate a control switch To simulate the behaviour of a switch e g to act on a digital output we need a conditional control and two controls to force the variable The conditional control would contain two images one with the representation of an open switch with the condition that the digital variable is 1 and another with the representation of a closed switch with the condition that the digital variable is O On 2 Off On of A control is positioned on the left part of the control to force a variable with a digital output value at 1 while another control is positioned on the right hand section to force a variable with the output value at O 3 2 18 How do add animation to the SCADA To add a small animated image the conditional control combined with the second function in the condition is ad
9. an event was enabled how many times it was deactivated how many it was recognized and how long it was enabled 3 2 24 How can I produce sounds in response to an event To produce a sound in response to an event we should add an action to run an external program and enter the corresponding WAV MP3 etc with its full path in the program field For the action to take effect you will need to have a program installed that can play back this type of file for example Windows Media Player Sonique Winamp etc If what is needed is simply reproducing a bleep on the client application an action associated with this event can be added to carry it out Likewise this action can occur during activation upon acknowledgement on deactivation or while active W Help to create an action What action do vou want to add Execute an external Show a device programme Show scada screen Show m Audible alarm Cancel Support for the audible alarm action on the client in response to an event 38 User Manual PowerStudio mi CIRCUTOR 3 2 25 How do show documents in response to an event In a similar manner to the previous point adding an action to run an external program and entering the file to be shown PDF TXT DOC etc and its corresponding path For the action to take effect you will need to have a program installed that can read this type of file for example Microsoft Word Adobe Acrobat Reader
10. dateTime gt 21112013230000 lt dateTime gt w lt field gt id 01 CVM144 AE id value 133233 605000 value field record lt recordGroup gt Result of the request from the Internet Explorer browser Where in the value field we have the desired value This request can be done directly from for example the Excel spreadsheet by simply writing this request in the dialogue Open instead of the name of a file Excel will interpret the previous XML and generate a table with data Libro Microsoft Excel Archivo Inicio Insertar Diseno de pagina Formulas Datos Revisar Vista E Calibri 11 g Insetar i hs P 24 i 3 NMA S A A TE WA 000 Eliminar i T Pegar _ A iem Estilos _ Ordenar 3 E T 00 30 Formato 24 y filtrar seleccionar Portapapeles Fuente Alineaci n N mero Celdas Modificar B7 Se A C 1 86400 2 1112 15 01 CVMIAA AE 133233 605 WM M 5 M 4 H Hojal 2 Hoja3 J li Listo ag 100 Open request with Excel 2010 In D1 we have the data 3 2 161 tried to make a table with the client application and get the Message Table too Big What can do to see it The client is a Java application As a Java application it runs on a virtual machine with a limited memory for it to run assigned by default
11. etc 3 2 26 How communicate with a TCP2RS converter by way of a router To communicate with a TCP2RS converter located in a sub network different to the network in which the software is located we can use a router as shown in the following image gt gt l we IP 192 168 120 201 IP 192 168 15 205 The TCP2RS converter should be added as follows Wy New TCP2RS Mame Description mmm Converter address User name Password Anonymous user Connection UDP Port Configuration port 10001 80 mr Setup Gy Advanced setup w Accept Cancel 1 Enter the router address 192 168 120 201 In the Converter Address field 2 Redirect ports 70001 30718 in the router to the converter address 192 168 15 205 see router manual 3 2 27 There are screens on which cannot see the text of the controls properly or they are truncated How can solve this The screens are designed to be properly viewed with a minimum size of 1024x768 You must increase the size of the window to the recommended minimum size if your screen is configured at 1024x768 you must maximise the screen User Manual 39 CIRCUTOR PowerStudio 3 2 28 When viewing a graph and selecting the tooltip the graph disappears How can solve this With some platforms when a graph is made and the tooltip is viewed it disappears and the background turns black If this
12. included in the request as var device variable If you want to ascertain the value of all the variables of a device it should be indicated as id device With it being possible in a single request to request the value of one or more variables and values of one or more devices values variable lt id gt Ig lt value gt value variable lt values gt Where e values Main field which will identify the XML as a response to the request for variable values e variable List of variables Identifier of the variable in device variable format Refer to the variable appendix in the Devices Manual value Value of variable at the time of the request 24 User Manual PowerStudio mi CIRCUTOR 3 1 5 services user forceVariables xml id device With this request we may send the order to force variables to PowerStudio The request must include the name of the device we want to force so that if necessary authentication can be checked see jError No se encuentra el origen de la referencia jError No se encuentra el origen de la referencia Only variables belonging to the device indicated in the request will be forced lt forceVariables gt lt forceVar gt forceName forceName gt forceValue forceValue forceVar lt forceVariables gt Where e forceVariables Main field that will identify the XML as a request to force variables e forceVar Informat
13. m CIRCUTOR ENERGY MANAGEMENT SOFTWARE POWERSTUDIO Standard SCADA Deluxe Version 4 0 USER MANUAL 1 4 M98232301 03 134 CE CIRCUTOR PowerStudio 2 User Manual CIRCUTOR PowerStudio DISCLAIMER CIRCUTOR SA reserves the right to make modifications to the device or the unit specifications set out in this instruction manual without prior notice CIRCUTOR SA on its web site supplies its customers with the latest versions of the device specifications and the most updated manuals www circutor com TE User Manual 3 CIRCUTOR PowerStudio CONTENTS DISCDATMER ancienne 0105000 01 3 CONTENT E 4 LOG OF BEY USIONS P a a 6 1 GENERAL DESCRIPTION 7 Te POW ERS TW DIO TOPOLOGIE S 7 1 1 1 UEM e RE 7 1 1 2 IX UID FAIRE T 1 1 3 editor quo ERNE 8 1 1 4 ERU FINU 8 1 2 POWERSTUDIO 9 TON 14 1 3 1 Configure the communications 14 1 3 2 Creute the application n ihe GU
14. 0 in decimal format These parameters must be verified in both the server and the client computers Remember to reboot the PC for the changes to become effective For other operating systems consult the specific method for configuring this behaviour 3 2 30 When run the client as an embedded applet in the webpage within a browser how can access as an anonymous user When the client is run as an embedded applet in the webpage within a browser the authentication is managed by the browser itself The authentication screen displayed by the browser usually only allows the user name and password to be entered If you wish to access as an anonymous user you must use the following access data User anonymous Password anonymous This will provide access to the system as an anonymous user as long as this profile has been defined in the engine by means of the editor 3 2 31 not able to create SCADA screens or reports or define events amp Where s the problem May be you have a standard version You should acquire a SCADA or Deluxe version 40 User Manual PowerStudio mi CIRCUTOR 4 MAINTENANCE AND TECHNICAL SERVICE In the case of any query in relation to unit operation or malfunction please contact the CIRCUTOR SA Technical Support Service Technical Assistance Service Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 902 449 459 Spain 34 937 452 900 outside of Spain email sat circutor es 5 GUARAN
15. EMENTS e Microsoft Windows o 2003 2008 and 2012 Server XP Home XP Profesional Service Pack 1 Vista Windows 7 and 8 32 bits versions o 2003 2008 and 2012 Server XP Profesional Service Pack 1 Vista Windows 7 and 8 64 bits versions e Client over any operating system with Java Virtual Machine JRE 1 7 0 Linux Windows etc e Host with i86 architecture Intel AMD for Engine and Editor 1 GHz or more e Atleast 1 GB of RAM e 1 GB free in HD depending on the number and type of equipment connected space should be increased at a rate of approximately 30 MB per device and year of data we want to save e CD ROM e SVGA monitor with al least 1024x768 1280x1024 or better recommended e Windows compatible Mouse and keyboard User Manual 21 CIRCUTOR PowerStudio 3 APPENDICES 3 1 XML Services PowerStudio provides a range of XML services to enable in some respects communication with other applications In requests where it is necessary to express a date and time both in service request and the data from the response these will be represented in UTC Universal Coordinated Time with the format DDMMYYYYHHMMSS two digits for the day two for the month four for the year and two for the hour minutes and seconds It is also possible to represent only a date as DDMMYYYY assuming that the time is 00 00 00 or represent an hour as HHMMSS Finally in cases where milliseconds are required these are r
16. ML as a response to the request e recordGroup Field that groups all the records of an event e device Device the records refer to e record Will Identify each of the records dateTime Date and time of the sample field Will identify each of the fields id lden value Value of the event User Manual 29 CIRCUTOR PowerStudio 3 2 F A Q 3 2 1 Some equipment is not communicating What could be happening Make sure your computer is switched on and in a mode which can communicate ensuring particularly that it is not in the set up or starting up mode Make sure your computer is connected to a PC or a compatible converter and that the wiring is correct Make sure there is no possibility of any interference in the cable run from the device to the PC or between the device and the converter If you are connected to a converter check that the latter is properly connected to the PC Verify that the grid is not overloaded with an excessive amount of devices If your computer is connected by way of a 232 485 converter make sure that the switches are in the correct position Make sure that the equipment bus does not have devices that communicate at different speeds or have the same device number Check that the PC port is working properly 3 2 2 A TCP2RS converter does not communicate What could be happening Make sure your computer is switched on and connected to the communications network Make sure there is no possibilit
17. PLT calculation has been done with more samples than expected 0x0004 The samples used in the PLT calculation do not have an equidistant separation in the sampling window 0 0008 Some PST used in the calculation of the PLT contain events in phase 1 0x0010 Some PST used in the calculation of the PLT contain events in phase 2 0x0020 gt Some PST used in the calculation of the PLT contain events in phase 3 0 0040 gt Some PST used in the calculation of the PLT are not complete e Harmonic value record fieldARM lt id gt us lt id gt lt element gt lt harmonic gt lt harmonic gt lt value gt lt value gt lt element gt lt fieldARM gt Variable identifier device variable 26 User Manual PowerStudio mi CIRCUTOR Element Registers from each of the harmonics harmonic Harmonics number value Harmonic value e Waveform value record lt fieldFO gt lt id gt n lt id gt lt element gt lt msec gt lt 7 msec gt lt value gt lt value gt lt element gt fieldFO Variable identifier device variable Element Information from each of the points that make up the waveform msec millisecond value value e EVQ event Record lt fieldEVQ gt lt id gt uo lt id gt lt value gt lt value gt lt gt phase duration duration averageValue averageValue previousValue pr
18. PowerStudio mi CIRCUTOR PowerStudio Scada If we select the No option the configuration will be sent to the engine with the detected errors and it is possible that it will not operate as desired If we select the Yes option a screen will appear reporting the detected errors Refer to the Editor Manual for a more detailed explanation If we select the Setup device baudrates option before sending the application an attempt will be made to communicate with the devices added in the application If communication cannot be made with any of them a dialogue will appear reporting the detected incidents Refer to the Editor Manual for a more detailed explanation Wy PowerStudio Scada Lab PowerStudio Scada Lab has been unable to configure speed of the following devices A CIRWATT B 01 CIR WATT TCP2AS A CIRWATT B 02 CIR WATT B 2 5 A CIRSWATT B 03 CIR WATT B TEP2RS CvH 36 96 2 5 EJ CvMk2 CV MEZ TEP2RS FJ EDMk TCP2AS EJ Unable ta establish communication with the device Make sure the device is corectly connected Unable to set up device speed for comunicatians Make sure device speed is the appropiate IF it s necessary manually modify device speed To manually canfiqure speed check device s manual Communication incidents report From the editor it is possible to configure the default options that appear on the export dialogue we must go to the Fi
19. TEE CIRCUTOR guarantees its products against any manufacturing defect for two years after the delivery of the units CIRCUTOR will repair or replace any defective factory product returned during the guarantee period No returns will be accepted and no unit will be repaired or replaced if it is not accompanied by a report indicating the defect detected or the reason for the return The guarantee will be void if the units has been improperly used or the storage installation and maintenance instructions listed in this manual have not been followed Improper usage is defined as any operating or storage condition contrary to the national electrical code or that surpasses the limits indicated in the technical and environmental features of this manual CIRCUTOR accepts no liability due to the possible damage to the unit or other parts of the installation nor will it cover any possible sanctions derived from a possible failure improper installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical disturbances in the supply Water if the product does not have the appropriate IP classification Poor ventilation and or excessive temperatures Improper installation and or lack of maintenance Buyer repairs or modifications without the manufacturer s authorisation User Manual 41
20. ance with a condition using as in the previous case the conditional control User Manual 37 CIRCUTOR PowerStudio 3 2 21 How can know the status of a device All devices have a variable caled STATUS that shows the status of the device using a numerical value for example CVM144 STATUS The meaning of this variable is the same for all devices and can be used in the conditional expressions see the appendix to check the types of variables and their possible values 3 2 22 How can display documents from a SCADA screen To show documents previously stored on the PC the run control can be used If we wish to show a PDF file we can enter its name directly including the complete path in the program field so that the file will open in the related defined program when running the screen and clicking on the control Likewise we can do this with any file type which has an associated program to open it DOC TXT HTML WAV MP3 MPG AVI etc N B This option will not work on systems which do not run Windows nor when using the applet 3 2 23 How can obtain an event according to the status of a device To produce an event according to the status of one or more devices use the STATUS variable of the device in the event activation status The possible values of the STATUS variable can be seen in the variable type appendix oince the events generate a number of variables associated to them we can even see how many times
21. ated for the first time In a SCADA screen if we are dealing with a condition nothing will appear and if we are dealing with a formula a dash appears until the value can start In a report if there is no data in this period and we cannot assess the condition of a conditional control nothing will be displayed and if we cannot assess the definition the same will occur It may occur that when assessing the formula we come across an invalid operation such as the square root of a negative number or a zero division in this case a question mark appears on the SCADA screen and the report will show the definition of the formula If we are unable to assess the condition of a conditional control nothing will be displayed It may not be possible to represent the assessment of the formula of an expression because either its control or assessment configuration returned an out of range value In this case the character will appear 30 User Manual PowerStudio mi CIRCUTOR 3 2 6 An event is not behaving as expected What could be happening When an event does not occur when you think it should or vice versa check that this condition can be fulfilled and make sure the event is enabled at some time by the calendar and that the condition can be fulfilled during that interval Verify that the devices involved in assessing the condition of the event communicate properly and ensure that the communication engine is running Make sure you
22. d lt date gt date eventId lt eventId gt annotation annotation value value record recordGroup lt main gt Where main Main field that will identify the XML as a response to the request recordGroup Field that groups all the records of an event id Event identifier record Will Identify each of the records date Event date and hour eventid Event identifier annotation Event annotation value Event value ON gt Event enabled OFF gt Event disabled Event acknowledged 3 1 8 services user recordsEve xml begin end id Returns information on events recorded by one or more devices between the dates begin and end Each of the devices on which information is required must be included in the request as id device var device variable The format of begin and end will be DDMMYYYY when you wish only to indicate the date in this case the hour will 00 00 00 or DDMMYYYYHHMMSS when both the date and the hour are specified Both begin as ena must be expressed in UTC Universal Coordinated Time 28 User Manual PowerStudio mi CIRCUTOR lt main gt recordGroup device device record dateTime dateTime fielg lt id gt us lt id gt lt value gt value lt field gt lt record gt lt recordGroup gt lt main gt Where e main Main field that will identify the X
23. d to show an image in applet it is not enough to enter the name of the image in the run control but rather we should enter the application we want to use to show the image and as a parameter the image to show N B The option to launch external applications very much depends on the system in which applet is running and it is highly probable that it will only work in the system for which the application has been developed 3 2 11 How can see the applet from a machine which is not running Windows The applet can be viewed without carrying out any other special action from all operating systems that have Java Virtual Machine 1 5 5 0 or later and an HTML browser Among others the following operating systems would satisfy these requirements Windows Linux Solaris SPARC Solaris x86 Solaris AMD64 Linux AMD64 etc 3 2 12 Can directly connect with a known IP when I execute the Applet What happens if there s authentication What parameters can use to configure the Applet application launch When launching the Applet you have the option to add parameters to modify its behaviour The available parameters are as follows e undecorated gt Launches the client without borders nor captions nor margins for resizing This feature is used to run the applet on embedded screens Multipunto CHAdeMO etc Example java jar AppletScada jar undecorated 32 User Manual PowerStudio mi CIRCUTOR e classic gt Launches the client with th
24. ded First save the images that make up the animation using the image manager ouppose your animation consists of a sequence of 3 images Assume further that we want our animation to change every second Therefore we will have to create a list of formulae on the SCADA screen which will return module 3 of the second function which will vary between the values 0 1 and 2 The function is as follows mod second 3 Let us suppose that this function is called MOD Now we can define a conditional control with 3 conditions where each condition displays one of the images that form the animation The following shows control properties MOD 2 LA mm Remove Condition False MOD 0 Control type Image Search for image Maintain aspect ratio Alignment Ex fl The result is that one of the images that make up the animation is shown every second As can be seen there are many combinations to be carried out and a large variety of opportunities to exploit using this technique 36 User Manual PowerStudio mi CIRCUTOR 3 2 19 How can simulate a level control There are two ways to do a level control on a SCADA screen The first one is to use a conditional control where each control is an image with a different level and where every condition indicates what should be fulfilled to reach this level Here are some images showing us specific examples with their conditions CVM 1 VI1 215
25. e classic look and feel instead of the substance option Example java jar AopletScada jar classic e multipleinstance gt Launches the client with permission to run if there is another client open For safety purposes the last version would check to ensure that there were no other clients open when running and would not run if there were We can override this restriction with this parameter Example java jar AppletScada jar multipleinstance e User user password password gt Automatically logs in with the specified user and password Example java jar AppletScada jar user john password xh234 e Sleep x gt Establishes the refresh time of SCADA screens for monitoring devices and for checking active and reported events It is set in milliseconds with a minimum of 20 ms Example java jar AppletScada jar sleep 200 e address port gt Indicates the http address IP or name to which the client will attempt to connect If necessary the engine is not in port 80 the port may also be indicated Example java jar AppletScada jar powerstudio circutor com 8080 3 2 131 am making my first screen or report and cannot add a background image or a still picture What is happening You should remember that the images that can be included on the SCADA screens and the reports must have been added previously through the image manager Therefore it is necessary before starting to design a screen or report to add the images you will need through the
26. e variables that are used in the reports can be consulted by requesting services user records xml which is documented in the XML user requests section Imagine then we have a report with the following appearance User Manual 33 CIRCUTOR PowerStudio ZO DAE 1 200 O00 1 100 000 1 000 O00 1 400 O00 1 300 000 900 000 800 000 100 000 eno Don Si DO 400 000 DOO 200 000 100 000 17 1 amp 19 27 21 zz Neu Report generated The report is grouped by day in particular we are viewing November 22th It shows that there are a number of values in red inside boxes the first value on the top left corner corresponds to the variable 01 CVM144 AE To see that value through a HTTP XML request to the server we can do the following http 192 168 3 3 8083 services user records xml begin 21112013230000 end 221120132300 00 period ALL var 01 CVM144 AE 34 User Manual PowerStudio mi CIRCUTOR This request if carried out with the browser will return something similar to the following 19216833 8083 services V aS ca a C 192 168 3 3 8083 services user records xml begin 21112013230000 end 22112013230000 period ALL var 01_CVM144 AE This XML file does not appear to have any style information associated with it The document tree is shown below w lt recordGroup gt period 86400 period v record lt
27. en I run the client as an embedded applet in the webpage within a browser how can I access SG Oy OS a EEN 40 3 2 31 not able to create SCADA screens or reports or define events Where s the problem 40 4 MAINTENANCE AND TECHNICAL SERV ICE e eee e eee etae eese es essoos 41 SA GUARANTEE 41 User Manual 5 CIRCUTOR PowerStudio LOG OF REVISIONS 1113 M98232301 03 13A Original version _ 6 User Manual PowerStudio mi CIRCUTOR 1 GENERAL DESCRIPTION PowerStudio is an energy management software package and its main features are the configuration communication and monitoring of devices and the creation of SCADA screens and reports It also has a set of tools such as events filters calculated variables and an images and styles manager to facilitate the user s interaction In its version 4 0 PowerStudio is divided into three main modules the applications editor the communications engine and the client The editor is the module that is in charge of applications management and it allows a new application to be created to modify an existing application to import an application from the engine or to export an application to the engine The engine is the module in charge of running the application it receives from the editor and of communicating with the differe
28. epresented with three digits after the seconds DDMMYYYYHHMMSSUUU HHMMSSUUU The requests must follow the URI standard RFC 2396 so the user of these requests must take into account this detail when making such calls especially in cases where the name of any device contains non ASCII characters It should also be taken into account that the length of the request may not exceed 4000 characters 3 1 1 services user devices xml Returns the list of configured devices devices lt id gt ue lt id gt erien Where e devices Main field which will identify the main XML as a response to the device list request e Name of each one of the devices 3 1 2 services user devicelnfo xml idzdevice Returns information on devices Each of the devices on which information is required must be included in the request as id device2 id device2 devices device lt id gt lt id gt lt description gt lt description gt lt type gt type typeDescription typeDescription var var device lt devices gt Where e devices Main Field which will identify the XML as a response to the device information request e device Information from each of the devices requested Name of the device description Description of device 22 User Manual PowerStudio mi CIRCUTOR Type of device for example CVM144 fypeDescription A description o
29. es when you think there should be ensure that you have not zoomed in an area without values or that the Y axis is not forcing levels for values which do not exist 3 2 8 The Paint Pot is not working correctly What could be happening If when placing the paint pot control on a SCADA screen it does not behave in the manner expected ensure that 1 The condition or conditions defined are right for each color 2 The area in which the control is positioned has a uniform color It is possible that the area where the paint pot is positioned has different colored dots but with very similar tones which at first sight appear the same The paint pot control only spreads through identical colors 3 The area to be filled with the colors defined in control is not part of another control The paint pot control only interacts with the screen background and does not take into account any of the other controls Do not attempt to use the paint pot to fill for example an image by way of the image type control User Manual 31 CIRCUTOR PowerStudio 3 2 9 The software is not sending e mails What might be happening Check that your anti virus is not blocking the software For security purposes the software does not send e mails if the mail server does not have the Transport Layer Security TSL option activated and the mail server only supports Plain Login or NTLM authentication protocols since these are not very secure for sending informat
30. eviousValue eventType eventType gt lt endForced gt endForced semicycleVoltage lt date gt date value value semicycleVoltage fieldEVQ Variable identifier device variable value Value of the event Phase Phase in which the event occurs duration Duration of the event in milliseconds averageValue Average value previousValue Old value eventType Type of event Ooilnterruption 1 gap gt Overvoltage endForced Mark if the event has finished correctly F or has be forced to finalise T semicycleVoltage Each of the points that make up the semi circular effective voltage associated with the event This field is optional and may not exist date Date and time DDMMYYYYHHMMSSUUU value Value 3 1 7 services user events xml begin end id Returns the events log of one or more events between dates begin and end Each of the events on which information is required must be included in the request as User Manual 27 CIRCUTOR PowerStudio id name event var device variable The format of begin and end will be DDMMYYYY when you wish only to indicate the date in this case the hour will 00 00 00 or DDMMYYYYHHMMSS when both the date and the hour are specified Both begin as end must be expressed in UTC Universal Coordinated Time main recordGroup lt id gt ns lt 1 gt recor
31. f the type of device for example CVM 144 var Name of each of the variables of the device The name will be expressed as device variable Refer to the variable appendix in the Devices Manual 3 1 3 services user varlnfo xml varzdevice variable 2idzdevice Returns variable information when carrying out the XML request Each of the variables from which a value is desired should be included in the request as var device variable And if you want to get information from all the variables of a device this must be indicated as id device With it being possible to request information from one or more variables and one or more devices in the same request varinfo var lt id gt lt title gt lt title gt lt hasValue gt T lt hasValue gt lt hasLogger gt T lt hasLogger gt sampleMode sampleMode gt measureUnits measureUnits unitsFactor unitsFactor lt 15 gt decimals gt ware lt varInfo gt Where e varlnfo Main field which identifies the XML as a response to the request for information about variables e var Information from each of the variables requested Name of the variable in device variable format Refer to the variable appendix in the Devices Manual title Brief description of the variable hasValue Indicates if it is possible to ask the instantaneous value of the variable T or not F hasLogger Indica
32. first have to import it then modify it and export it to the engine so that the new changes are included 1 3 8 Export the application to the engine When we have completed an application or an existing one has been modified we must export it to the communications engine so that the latter takes all the changes made into account While we are editing an application the communications engine continues to run the last application configured in it and it is not until we export it from the client that these changes are implemented in the engine Refer to the Editor Manual for a more detailed explanation From the editor shortcut toolbar if we select the option we will access the application s export dialogue W Export application Engine address IP localhost Port 8083 The communication engine requires authentication name john Password 659 Check application Setup device baud rates amp f Accept Cancel Export application In the export dialogue we must select the IP address and port of the engine to which we are going to send the configuration we will also mark the The communication engine requires authentication option and enter the user and password if user authentication is enabled If we select the Check application option before sending the application it is verified to be correct and the following message will be displayed if there is invalid data 16 User Manual
33. have permission to see this type of event and you have checked the notify and or register box If the incident appears not to have carried out actions that have been defined check what has actually occurred in the list of events If the event has still not produced the programd action or actions check that the equipment upon which it should have acted is on and communicating correctly Should the action involve the running of an external application check that the application is properly installed and that the command and parameters are correct you can put this action in a run control in a SCADA screen test to see if it behaves as expected 3 2 7 1 can t paint the graph correctly What could be happening If the graph appears to have dots missing verify that this is not because the variables are being represented with different periods If the bar charts has widths that are not correct ensure that the values are separated by the distance marked by the driver period For example if a device saves data every 5 minutes and we change the period to 15 minutes the bars will be superimposed when displaying the bar graphs for the values prior to the change of period every 5 minutes If we change the period to a lower value the bars prior to the change will appear narrower than necessary In any case the bar graphs of values separated by the distance shown in the Driver registration period will always appear correctly If you do not see any valu
34. image manager 3 2 14 What can be counted Any event added to the system contains a variable that indicates how many times it has been enabled how many times it has been recognized how many times it has been deactivated how long has it been active if it is active at the moment and how much time has elapsed since it was last enabled One can also count how many times something has occurred in the current hour day etc For this purpose a forced calculated variable will be created and initialized to 0 and an event which when a condition is fulfilled performs the action of forcing that variable to its same value plus one unit RSCAL FORCED COUNTER1 RSCAL FORCED COUNTER 1 1 We then just need to add an event that would reset this counter to 0 when the date was outside XX XX XX 00 00 00 00 00 00 hours each day with which the counter would have the number activations of the day in course The counter reset could be carried out with a variable forced control on the SCADA screen in this case manual instead of automatic 3 2 151 would like to export the report data in order to process it later How can do it The data displayed in a report is log data grouped together for the period of the report therefore we have a value per period if it is an expression where several variables are involved the value of each variable is recovered for the period of the report and the expression assessed For practical purposes the values of th
35. ion If this is the case gt increase the security of your mail server and in order to allow the software to send e mails TLS SSL encryption should be enabled If you want you can add another authentication method such cram md5 digest md5 gssapi or an external one f TLS has not been activated one of the previously suggested authentication proposals should be added the protocols already functioning in the mail server can be retained since they will not be used by the software The authentication method for the smtp server CANNOT be any of the following plain login or ntlm gt Ifthe system still does not send mails check that your e mail server has a user with the same name as the configured address The software will use the configured e mail address for the user 3 2 10 Can I launch external applications from applet For security reasons Java Applets have some fairly significant limitations with regards accessing the resources of the local machine on which they are running One of these restrictions is being able to run applications on the local machine Nevertheless this restriction may be disabled by adding the following line to the java policy permissions file situated in the installation of the JRE virtual machine permission java io FilePermission ALL FILES gt gt execute It must be noted however that the Applet cannot directly display files from the run control in the way SCADA can So if we wante
36. ion on each of the variables to be forced forceName Name of the variable in device variable format Refer to the variable appendix in the Devices Manual Only variables that can be forced for example digital output variables forceValue Value to which we wish to force the variable 3 1 6 services user records xml begin end var period 900 Returns information on one or more variables between the dates begin and end Each of the variables that the information is required from should be included in the request as var device variable var device variable The format of begin and end will be DDMMYY YY when you wish only to indicate the date in this case the hour will 00 00 00 or DDMMYYYYHHMMSS when both the date and the hour are specified Both begin as end must be expressed in UTC Universal Coordinated Time Finally we may specify the period of data grouping using the period parameter This value may be FILE gt data not grouped returning the register as they have saved in the log AUTO gt Grouping will take place automatically depending on the specified dates begin and end ALL gt Data is grouped into a single value gt 0 gt Value in seconds in which the data is grouped If the period parameter does not appear on the request it shall be considered as value 0 and the data will not be grouped recordGroup period period record dateTime
37. is configuration we have an editor an engine and one or more clients each of these being on different machines This configuration allows the engine configuration to be edited remotely This configuration is used when we want the data downloaded from the devices by the engine to be centralized in a machine that is independent of the editor machine 5 S Se J 1 1 4 Engine editors and clients This configuration is the same as the previous one with the only difference that it is possible to edit an application from two machines at the same time For example the SCADA screens could be configured from one editor and the reports from another It is important that each editor must import the engine configuration before new changes are made When modifying the application and exporting it to the engine were any type of incongruity to occur with the engine application we will be able to correct it 8 User Manual CIRCUTOR PowerStudio Once it has been ascertained that your machine meets the minimum requirements for the software insert the PowerStudio CD and select the install software option that will appear on the main screen If the main screen does not appear automatically when the CD is inserted in the unit you must manually run from Windows explorer or with the Run option on the START menu the AUTORUN EXE program which is in the CD s root directory Circular PowerStudio Seada GN Choo
38. le gt Engine preferences menu option Refer to the Editor Manual for a more detailed explanation User Manual 17 CIRCUTOR PowerStudio Engine preferences Mame G Engine01 localhost Engine02 Mare engines lt lt C Enginen2 localhost Engine address IP a localhost Delay 8034 0 v The communication engine requires authentication User name usuario Password 6665 Engine public address IP Port 192 168 3 3 aaz 8034 amp Accept Cancel Engine preferences 1 3 4 View the application in the client From the Client we can connect with the engine to view the application by selecting the General gt Connect menu option Refer to the Client Manual for a more detailed explanation TCP IP address Z Fort P Cancel Connect to the engine Below some of the views obtained from the Client are shown such as the device status view the machine monitoring view or SCADA screen only in SCADA and Deluxe versions 18 User Manual PowerStudio CIRCUTOR Wy Devices status PowerStudio Scada 8 Options Views General Previous o9 Next v Devices 5 screens CBS 4 25 cBs4 TCP2RS TCP2RS 002645003949 TCP2RS 002645001775 g Computer Plus EJ 15_COMPUTERPLUS AM cvm 144 03 CVM144 04 CVM144 05 144 16 144 01 A 144 Ethernet 17_cvm144 02 CVM144
39. lowing The engine is not operating or not found The engine is active there are no events or problems with the communications O The engine is active there are no events but there are problems with the communications O The engine is active there are problems with the communications and active events O The engine is active there are no problems with the communications but there are active events It is necessary to start the communications engine so that the Engine Manager can configure the web server parameters By default the communications engine attempts to start the web server on port 80 and if it is busy it seeks a free port as we have seen these parameters can subsequently be changed with the Engine Manager 1 3 2 Create the application in the editor To create a new application the following main steps must be performed Add and configure devices Add first and second level devices and configure the communications parameters Refer to the Devices section in the Editor manual Create device groups Organize the devices into groups according to the structure defined by the user Refer to the Device groups section in the Editor manual Create filters Create one or more energy filters to apply to the data gathered by the devices Refer to the filters section in the Editor manual Create calculated variables Define new variables with values of different devices Refer to the Calculated
40. nt devices storing downloads and attending to the various requests made by both the editor and the client The client is the module that allows connection with an engine and access to the SCADA screens reports and to view the instantaneous values recorded by the devices Graphs and listings can also be prepared of the recorded values events can be viewed the status of the devices can be displayed etc 1 1 POWERSTUDIO TOPOLOGIES PowerStudio s software design as three well differentiated modules the editor the engine and the client make it possible to use it through different topologies which are explained in detail below 1 1 1 All in one This is the basic configuration in which the three modules the editor the engine and the client are on the same machine With the editor we can create a new application to send to the engine and from the client connect to the engine to display the application From the editor we can also download an existing application from the engine modify it and then send it back to the engine 1 1 2 Engine editor and clients In this configuration we have the editor and engine on one machine and from one or more clients on other machines we connect with the engine to access the viewing of data SCADA screens reports etc This configuration is useful when we want to view the engine data remotely from the client User Manual 7 CIRCUTOR PowerStudio 1 1 3 Engine editor and clients In th
41. occurs you must start the client with the following command line java Dsun java2d d3d false AppletScada jar 3 2 29 cannot connect with the engine or some TCP IP devices has errors On the Java console see java net BindException Address already in use connect How can solve this The PowerStudio client application continuously makes many connections to the server In Windows the open sockets ports for making the connection are limited and in addition they cannot be used for a specific amount of time after having been freed up WAIT Thus in Windows XP for example by default the user applications are allowed to use ports 1024 to 5000 and also by default a port will remain in the TIME WAIT state for 4 minutes after it is closed before finally being freed up by the operating system In Windows it is possible to change this policy by modifying or creating two registry keys that define this behavior you need to execute regedit application for Windows These keys are MaxUserPort TcpTimedWaitDelay Located in HKEY LOCAL MACHINE System CurrentControlSet Services Tcpip Parameters Both keys are DWORD type and you have to create them if they are not available In the first we assign the maximum port number which is set at 5000 by default and we can set it at 20000 in decimal format In the second we define the time in seconds that we want a port to remain reserved after having closed it for example we can set it at 3
42. oses or where the copy or adaptation is essential for the authorised use of the Software All intellectual property warnings from the original software must be reproduced on all copies or adaptations The Software cannot be copied on any public network Cancel License terms Then press the button where you will be required to register the product and enter the user name the company name and software serial number Circutor PowerStudio Scada InstallShield Wizard Lustomer Information Please enter your information Please enter your name the name of the company for which you Work and the product serial number User Company Mame Serial Number lt Back gt Cancel Register screen 10 User Manual PowerStudio ag CIRCUTOR Then press the button and you will access the installation type selection screen We can choose the complete installation which will install the Editor the Engine and the Client or the custom installation where we can select the modules to be installed Setup Select the setup type to install Please select a setup type Complete All program features will be installed Requires the most disk space Select which program features you want installed Recommended for advanced users Installshield Back i Next gt Cancel Installation type After completing the installation preparation proces
43. s operating parameters such as the web server and the working directories gt PSEngineManager 2 1 Http Engine view Engine Manager This view only provides the engine view To modify the parameters we will use the Modify button and the following dialog will appear 5 PSEngineManager 2 1 Http Port 80 User Password Repeat password locale Timezone System Folders Data C ProgramData Circutor PowerStudio Scada Data Cfg C ProgramData Circutor PowerStudio Scada Cfg Images C ProgramData Circutor PowerStudio Scada Cfg Images te ext Engine configuration Engine Manager 14 User Manual PowerStudio mi CIRCUTOR Port We indicate the port that the engine will use to initialize the web server The editor and client requests will be attended to on this port User User used if we desire edition authentication Password We indicate the user password for edition authentication Repeat password Re enter password to validate it Timezone Allows you to enter a different time zone from that of the system Data Working directory for storing the data downloaded from the machines Cfg Working directory to store the application s configuration Images Working directory to store the application s images On the upper right hand part of the screen we will see an image indicating the engine status The possible statuses are the fol
44. s a dialogue will appear where you will be asked for the application installation directory Circutor PowerStudio Scada InstallShield Wizar Choose Destination Location Select Folder where setup will install files fu Install Cireutor PowerStudio Scada to Cy A CirenibarsPewerStudia Scada User Manual 11 CIRCUTOR PowerStudio On the next screen we can select the module or modules to be installed You must only select the components that are required for the selected topology See section 1 1 PowerStudio topologies for further explanation Select Features Select the features setup will install Select the features want ta install and deselect the features you do not want to install Description Allows system editing 191 46 MB of space required on the drive b38753 52 MB of space available an the C drive installed _ Components selection If the installation detects that you have already installed a previous version of PowerStudio it will allow you to make a backup copy of the configuration before you update to the current version Love If you wish to make a backup copy the Backup directory will be created within the directory where you are installing PowerStudio and the old configuration will be backed up If you do not wish to make a backup copy the old configuration will be lost Updating configuration to version 4 0
45. se Setup Language Select the language for the installation from the choices below English United States Installation language After selecting the installation language and pressing the Nex f button we will access the license screen where we must accept the terms to be able to continue User Manual 9 IHL LI TUR PowerStudio Circutor PowerStudio Scada InstallShield Wizard License Agreement Please read the following license agreement carefully LICENSE CONDITIONS FOR CIRCUTOR SOFTWARE These Licence Conditions govern the use of CIRCUTOR software accompanying products with the same name PowerStudio Scada n are Granting the licence CIRCUTOR S A grants one user license for one copy of the top yp Software The Use induded the use storage loading installation running and display of the Software Itis prohibited to modify the Software disable any of the control functions or change the Software license 2 Ownership CIRCUTOR 5 4 or its suppliers are the owners of the Software and also own the intellectual property rights This licensed does not grant any ownership nor possession of the Software nor does it constitute the sale of the rights for the Software CIRCUTOR 5 and its other suppliers may protect its rights in the event that the Licence Conditions are not fulfilled 3 Copies and adaptations The Software can only be copied or adapted for file purp
46. tes whether it is possible to ask the log value of the variable T or not F sampleMode Variable type mode used to group together the values of a variable none Without type average Average value max Maximum value min Maximum value pfAverage Power factor average value pfMax Power factor maximum value pfMin Power factor minimum value last Last value differential current Differential current value between the current value and the previous one samples samples The value cannot be grouped discrete Discreet values The value cannot be grouped measureUnits Variable units NONE gt Without units 9 9 9 9 9 User Manual 23 CIRCUTOR PowerStudio gt Voltage gt Current VA gt Apparent power W gt Active power VARL gt Inductive power VARC gt Capacitive power PF gt Power factor HZ gt Frequency PERCENT gt Percentage WH gt Active energy VARLH gt Inductive energy VARCH gt Capacitive energy DATETIME gt Date and time If not preceded by it is a user defined unit UunitsFactor Power of 10 that indicates the value the variable is multiplied by in the log file decimals Decimals with this variable 9 9 99 9 99 9 9 99 9 3 1 4 services user values xml varzdevice variable idzdevice Returns the instantaneous value of the variable when the XML request is carried out Each of the variables that the value is required from should be
47. tor 0 80 0 81 0 81 0 81 Total distortion 96 0 4 0 4 0 4 Cosine phi 097 097 097 097 Frequency Hz 50 0 r Generated power Active KW 0 0 0 0 0 0 0 0 Capacitive kvarC 0 0 0 0 0 0 0 0 r Current Inductive kvarL 0 0 0 0 0 0 0 0 Current A 9 2 9 2 9 2 Apparent 0 0 0 0 0 0 0 0 Power factor 0 00 0 00 0 00 0 00 Cosine phi 0 00 0 00 0 00 0 00 Neutral current A 27 7 i Active quadrant Active quadrant 2 Total distortion 96 1 1 1 1 1 1 m Maximum demand consumed Digital outputs Max active P demand KW 144 0 Digital output 1 Opened Max aparent P demand kVA 178 0 Digital output 2 Opened Max current demand A 9 2 9 2 9 2 9 2 Digital output 3 Opened r Maximum demand generated Max active P demand KW 0 0 ET Opened Max aparent P demand kVA 0 0 Maximumiminimum reset Server Ok LiveTest labtest3 8083 Device monitoring screen UK 04 OFFICE PowerStudio Scada Options Views General Q e Next v Devices screens Reports FE Np ees af Properties b vic CIRCUTOR OFFICE CONSUMPTION POWERSTUDIO Parameters Value Graph Table Report Voltage 227 6 TH Current d 114 C HE 25 i Active power Power factor THD U Server Ok Circutor powerstudio circutor com 80 Client application with a SCADA screen as an active view 20 User Manual PowerStudio mi CIRCUTOR 2 SYSTEM REQUIR
48. variables section in the Editor manual Create styles Define styles configurations to apply to the fonts of the various controls of SCADA screens and reports Refer to the Styles section in the Editor manual Manage images Add the images required for subsequent use in SCADA screens and reports Refer to the Images manager section in the Editor manual Create SCADA screens only in SCADA and Deluxe versions Create one or more SCADA screens which allow for visually displaying the application Refer to the SCADA section in the Editor manual User Manual 15 CIRCUTOR PowerStudio Create reports only in SCADA and Deluxe versions Create one or more templates for displaying reports Refer to the Reports section in the Editor manual Create events only in SCADA and Deluxe versions Define application events disabled schedules filters and their configuration Refer to the Events section in the Editor manual Define user rights and authentication Configure one or more profiles relating to the application resources and assign to the users Refer to the User authentication section in the Editor manual Create device zones Define the application zones grouping the devices that we want to display together in a screen Refer to Zones section in the Editor Manual If we wish to modify the application in the communications engine we
49. y of any interference in the cable run from the converter to the PC Make sure your PC is correctly connected to the communications network and can communicate with other equipment connected to the network for example with another PC If you are using a router make sure the communication port is redirected in the router to the converter address 3 2 3 cannot see the applet What could be happening Check that the local computer has the Microsoft Internet Explorer Netscape Mozilla or Firefox browser installed Ensure that the Java Virtual Machine JRE 1 6 6 0 or later is installed If they are not installed the browser will provide information and guide us through the installation process If the applet appears but a message is displayed warning that there is communication with the server or the required information could not be recovered ensure that the communications engine is running 3 2 4 The Applet does not display the texts properly What could be happening It is possible that some fonts applied to the controls when designing a report or a SCADA screen do not exist on the machine on which the applet is downloaded and as a consequence the font chosen may be markedly different from the original 3 2 5 The values display is not what expected What could be happening It is possible that a conditional control or a formula refers to a variable of a device which does not communicate or that has not yet been interrog