1. SNMP reset enable Then Reset button will become available Click Refer to Diagram 3 4 EE SNMP Manager System Settings Language Help IP address UPS name Address 192 168 103 230 Test Ups Name Address v SNMP reset enable 192 168 103 230 Er Basic Info IP settings Online upgrade Password management Static trap address MAC address F E Ft Change Automatically obtain IP address Use a static IP address IP address 192 168 103 230 Subnetmask 255 255 255 0 Default Gateway 192 168 103 254 Reset Apply Output window 14 16 08 192 168 103 230 Online successfully 14 23 30 Communication fails Please check your network Diagram 3 4 Step3 Click the Reset button and then prompts the user to confirm the operation Refer to Diagram 3 5 E SNMP Manager System Settings Language Help IP address P _ UPS name Address Address Basic Info IP settings Online upgrade Password management Static trap address MAC address Change Automatically obtain IP address Use a static IP address EFRR PI ORE 4 03 169 103 230 Confirm d Are you sure to operate 192 168 103 230 5 255 255 0 Yes No 2168 103 254 V SNMP reset enable Apply Output window 192 168 103 230 Fetan 14 16 08 192 168 103 230 Online successfully Add 14 23 30 Communication fails Please check your network
2. You may configure two static trap addresses and change trap port in SNMP Manager The default trap port is 162 Refer to Diagram 4 13 15 ie SNMP Manager System Settings Language Help Fanless upa nana Address Note Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 TestUps Name Address Note E lt Baba Trap IP Address Trap com IP address 1 1 92 168 102 202 Communication port 1 62 IP address 2 1 92 168 103 21 Select device J Select all SNMP reset enable Output window 192 168 103 230 oo 14 47 45 192 168 103 230 Online successfully Add Diagram 4 13 NOTE The SNMP device could provide 2 static trap addresses and 8 dynamic trap addresses The SNMP device will automatically load the IP address of host machine which installed monitoring software as dynamic trap address If there are over 10 minutes inactive for the dynamic trap address then the SNMP device will automatically release it for to load new dynamic trap 4 3 Language SNMP Manager offers 12 languages V Chinese Simplified V Chinese Traditional V English V German v Italian v Polish vV Portuguese vV Russian vV Spanish V Turkish 16 vV Ukrainian vV French The default language setting would be English 4 4 Help About Click Help menu and select
3. About item It represents the copyright information about software Help Click Help menu and select System help item It will open the help manual Before operating software please read manual carefully 17
4. Diagram 3 5 Step4 Select Yes you will be prompted to log in select No the suspension of operation Refer to Diagram 3 6 E SNMP Manager System Settings Language Help IP address UPS name Address Address Basic Info IP settings Online upgrade Password management Statictrap address for MAC address Change Automatically obtain IP address Use a static IP address 4 168 103 230 Please login first 255255 0 Password coccuece 168 103 254 Login Cancel SNMP reset enable Reset Apply 192 168 103 230 Goan Output window 14 16 08 192 168 103 230 Online successfully 14 23 30 Communication fails Please check your network 14 26 27 192 168 103 230 Wrong password entered Please retry to logon 14 26 47 192 168 103 230 Wrong password entered Please retry to logon Add Diagram 3 6 Step5 Enter the correct password and then click Login button the target device will be restarted NOTE If before you reboot change the current device MAC address and the current device is the use of DHCP Automatically obtain IP address then reboot you need to manually click on Scan button to scan 4 SNMP Manager Function Menu 4 1 System 4 1 1 Login When remote login to access SNMP devices it s necessary to verify ID The default password is 12345678
5. Diagram 4 10 12 192 168 103 DASNMP 0201 03 51 Browse Upgrade ie selected devte Jpgrade all un upgraded aeyices FOrce 16 Upgrade ail devices Lose Corel 192 168 103 230 Start formatting 192 168 103 230 Formatting is completed 192 168 103 230 Upgrading files Please wait 192 168 103 230 Upgrade fails Start upgrade for the 3 time 192 168 103 230 Start formatting 192 168 103 230 Formatting is completed 192 168 103 230 Upgrading files Please wait Diagram 4 10 13 Step3 When upgrade is complete you may check the message in output window Refer to Diagram 4 11 af SNM P Manager gt EEN System Settings Language Help IP address UPS name 192 168 103 230 _ Address Basic Info IP settings Online upgrade Password management Static trap address Target file path DASNMP 0201 03 519 Browse Upgrade the selected device C Upgrade all un upgraded devices C Force to upgrade all devices 100 Upgrade _ SNMP reset enable Output window 192 168 103 Scan 14 51 26 192 168 103 230 Formatting is completed Add 14 51 26 192 168 103 230 Upgrading files Please wait Del 14 51 42 192 168 103 230 Upgrade fails Start upgrade for the 3 time 14 51 42 192 168 103 230 Start formatting 14 51 46 192 168 103 230 Formatting is completed 14 51 46 192 168 103 230 Upgrading files Plea
6. devices 2 SNMP Manager Install Quick Start and Uninstall Supported OS gt Vv Vv Vv VY V WV Windows 2000 Windows XP 2003 Vista 2008 32 bit amp x64 bit Windows 7 32 bit amp x64 bit Linux RedHat 8 9 Linux RedHat Enterprise AS3 AS5 AS6 32 bit Linux SUSE 10 32 bit Linux Cent OS 5 4 32 bit Linux Ubuntu 8 X 9 X 10 X 32 bit Linux Fedora 5 Linux OpenSUSE 11 2 32 bit Linux Debian 5 x 6x 32 bit Mac OS 10 6 x64 bit Mac OS 10 7 x64 bit Vv Vv Y Y VY V WV Solaris 10 for x86 32 bit 2 1 Software Installation Install the ViewPower Pro software bundled inside of SNMP agent package 2 2 Software Quick Start To launch SNMP Manager choose SNMP Manager by clicking right button of the mouse Refer to Diagram 2 1 A arimani Stop Monitor SMMP Manager Configuration Https d Sofware Update Open Monitor Exit Diagram 2 1 2 3 Software Uninstall Since SNMP Manager is a plug in of Viewpower Pro software it s impossible to uninstall it only 3 SNMP Manager GUI The GUI has four sections as marked in the illustration below NMF Ml nayt System Settings Language Help A IP address UPSname Address Note 192 168 103 230 TestUpsName Address Note Basic Info IP settings Online upgrade Password management Static trap address MAC address 0 ME Change C Automatically obtain IP address Use a static IP addres
7. static IP address 192 168 103 230 Please enter the IP address 255 255 255 0 1 92 168 103 192 168 103 254 Apply Cancel SNMP reset enable 192 168 103 230 NW scan Add Apply Output window 14 16 08 192 168 103 230 Online successfully Diagram 3 2 3 1 3 Delete IP Address Select unnecessary IP address from list and 3 1 4 Reset click Del button to delete from list If it requires restarting the device IP addresses please select the SNMP reset enable and click on the Reset button then confirm the login you can restart the device Steps are as follows Step1 Selected from the IP list of equipment needed to restart IP At this point SNMP reset enable will be checked into Refer to Diagram 3 3 SNMP Manager System Settings Language Help IP address UPS name Address 192 168 103 230 TestUps Name Address SNMP reset enable nese 192 168 103 230 Scan Add Basic Info IP settings Online upgrade Password management Static trap address MAC address Change Automatically obtain IP address Usea static IP address IP address 192 168 103 230 Subnetmask 255 255 255 0 Default Gateway 192 168 103 254 Apply Output window 14 16 08 192 168 103 230 Online successfully 14 23 30 Communication fails Please check your network Diagram 3 3 Step2 Check the
8. SNMP Manager User s Manual Table of Contents 1 MV EE OCU CUNO IN icena E E ENEA 1 2 SNMP Manager Install Quick Start and Uninstall eeeseeee 1 2 1 Software Installation 2 00 00 cccssccessecesseccssseesssecessecsssesessesesseesseeeeneeens 2 2 2 S ftware QUICK Sea avis i ee eee ee ee 2 2 3 Software Uninstall a ccc cccsscccsecesecessscessseesseecessecesesessesesseeceseseeeens 2 3 SNMP Manager GUL eurc 3 4 SNMP Manager Function Menu wu sscccccccccssssssssscccccccccssssssssssccceeceeesssees 7 4 1 SVS TEI ee eee ee nnn een E enemy er eer eer rey eae 7 Ale EOM asirna a A Re 7 Aro LOGOUU i a oe ees 7 ALa OMI eee a se aera ese see 7 4 2 Setlihg S rrea a oe rea ene eee ae ee Pere ene Pere er ier ee rete et reer aoe 8 d2 RM Basie 0g ee ce eR rn i A 8 A222 IP SQtunG saccatccaucseeenanceceeuanteoiruern iota iouinennioueeannae 8 4 2 3 Online pgradEecciccnecnn pean eth ee ney te eee TD ee ne de ees 11 4 2 4 Password management eeeeeeseeseesresrreerissrirsressressressressresrresrresrresrresre 14 4 2 5 Static trap address ccc ccccssccssssccsssscsssssesesssscssssscssssesesseeseees 15 4 3 L ang adg oana AES 16 4 4 HeD a E E eect et ateetec oes ee ee 17 1 Introduction SNMP Manager is a plug in for ViewPower Pro software Users can search and operate all SNMP devices in the LAN via this interface Then ViewPower Pro will automatically search and monitor these SNMP
9. Stepi Select System gt gt Login Step2 Enter default password and then click Login button Or click Cancel to cancel login Refer to Diagram 4 1 iS SNMP Manager System Settings Language Help IP address UPS name Address a Basic Info IP settings Online upgrade Password management Static trap address Address MAC address _ Change C Automatically obtain IP address Use a static IP address 168 103 230 Please login first i 1 255 255 0 Password 168 103 2564 Login Cancel SNMP reset enable Apply Output window 192 168 103 230 Pecan 14 16 08 192 168 103 230 Online successfully Add 14 23 30 Communication fails Please check your network 14 26 27 192 168 103 230 Wrong password entered Please retry to logon 14 26 47 192 168 103 230 Wrong password entered Please retry to logon Diagram 4 1 4 1 2 Logout Clear all currently saved passwords 4 1 3 Quit Select Quick to exit SNMP Manager 4 2 Settings 4 2 1 Basic Info User can enter basic information such as UPS name Address Note and so on for SNMP card manually in order to easily distinguish the SNMP cards Refer to Diagram 4 2 ie SNMP Manager Pe System Settings Language Help IP address UPS name Address P rA ae __Note Basic Info IP settings Online upgrade Password managemen
10. button will become clickable Refer to Diagram 4 4 3 SNMP Manager System Settings Language Help IP address UPS name 192 168 103 230 Test Ups Name Address Address SNMP reset enable 192 168 103 230 Basic Info IP settings Online upgrade Password management Static trap address MAC address 00 FF E 00 12 F1 v Change Apply Automatically obtain IP address Use a static IP address IP address 192 168 103 230 Subnetmask 255 255 255 0 Default Gateway 192 168 103 254 Apply Output window 14 16 08 192 168 103 230 Online successfully 14 23 30 Communication fails Please check your network 14 26 27 192 168 103 230 Wrong password entered Please retry to logon 14 26 47 192 168 103 230 Wrong password entered Please retry to logon Diagram 4 4 Step 3 After modifying MAC address click Apply button then the user is prompted to confirm the operation Refer to Diagram 4 5 ie SNMP Manager System Settings Language Help IP address UPS name Address Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 TestUpsName Address l MAC address 00 FF E 00 12 F1 Change Apply Automatically obtain IP address Use a static IP address 1D matron nn laga 168 103 230 Confirm 4 4 s Please confirm again 192 168 103 230 29 255 255 0 Yes No 92 168 103 254 SNMP reset enable Apply 192 168 103 230 Output win
11. dow 14 16 08 192 168 103 230 Online successfully 14 23 30 Communication fails Please check your network 14 26 27 192 168 103 230 Wrong password entered Please retry to logon 14 26 47 192 168 103 230 Wrong password entered Please retry to logon Diagram 4 5 Step 4 Confirm the operation it will prompt Operation success Refer to Diagram 4 6 32 SNMP Manager PE System Settings Language Help IP address UPS name Address Note Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 TestUpsName Address Note MAC address IP address Subnet mask Default Gateway 192 168 103 230 Output window SSS Sy gt e SS SS SS Se SS ee a ee a your network 14 30 33 Communication fails Please check 14 31 39 192 168 103 230 Online successfully 14 31 40 192 168 103 230 Online successfully 14 31 41 192 168 103 230 Online successfully 14 31 41 192 168 103 230 Online successfully 14 31 48 192 168 103 230 Online successfully 14 31 53 Operation success Diagram 4 6 Part 2 There are two methods to obtain IP address Automatically obtain IP address DHCP Manually configure IP address 10 The system will default automatically obtain IP addresses If there is no this kind of service provided in LAN the default IP will display as 192 168 102 230 Net mask as 255 255 255 0 and default gateway as 0 0 0 0 Ref
12. elp IF address UPS name Address Note Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 TestUpsName Address Note F g E i l Target file path D SNMP 0201 03 51 g Browse Upgrade the selected device Upgrade all un upgraded devices Force to upgrade all devices Upgrade SNMP reset enable 192 168 103 230 Ee UEDA 14 34 03 192 168 103 230 Online successfully 14 34 16 192 168 103 230 Online successfully 14 37 12 192 168 103 230 Online successfully 14 37 51 192 168 103 230 Online successfully 14 37 51 192 168 103 230 Online successfully 14 42 05 192 168 103 230 Online successfully 14 42 06 192 168 103 230 Online successfully Diagram 4 8 Step1 Click Browse button to choose program file Refer to Diagram 4 9 S SNMP Manager fs System Settings Language Help IP address UPS name Address Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 Target file path DASNMP 0201 03 51 g Browse Open Lookin O snmp E 0201 02 819 SNMP reset enable 192 168 103 File Name 0201 02 519 Files of Type AllFiles Open Cancel TST 46 G7 T68 T03 Z230 Fortriatnia OMMipleted 14 51 46 192 168 103 230 Upgrading files Please wait 14 51 57 192 168 103 230 Upgrade is completed Diagram 4 9 Step2 Click Upgrade button to execute upgrade action Refer to
13. er to Diagram 4 7 a SNMP Manager System Settings Language Help IP address UPS name Address Note Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 TestUps Name Address Note E j l i l MAC address Change C Automatically obtain IP address Use a static IP address IP address 192 168 103 230 Subnetmask 255 266 255 0 Default Gateway 192 168 103 254 SNMP reset enable Apply 192 168 103 230 e Output window 14 31 41 192 168 103 230 Online successfully Add 14 31 48 192 168 103 230 Online successfully 14 31 53 Operation success 14 33 16 192 168 103 230 Online successfully 14 33 56 192 168 103 230 Online successfully 14 34 03 192 168 103 230 Online successfully 14 34 16 192 168 103 230 Online successfully Diagram 4 7 4 2 3 Online upgrade There are three methods for online upgrade Upgrade the selected devices It will upgrade all SNMP devices listed on the window Upgrade all un upgraded devices It will only upgrade SNMP devices which are not using the same version as current SNMP device is Force to upgrade all devices No matter what kinds of version are used for SNMP devices listed in the window list it will upgrade to the version used for current SNMP device Refer to Diagram 4 8 11 ie SNMP Manager System Settings Language H
14. s IP address 192 168 103 230 Subnet mask 255 255 255 0 Default Gateway 192 168 103 254 SNMP reset enable t Apply 192 168 103 230 Output window 14 16 08 192 168 103 230 Online successfully D Diagram 3 1 A Function menu offers complete tool set for navigating and setting the GUI B SNMP device list can list down all SNMP devices located in current IP address C Configuration area includes IP settings online upgrade password management and static trap address D Output window displays all messages for operations 3 1 SNMP Device List The default value in window list would be current PC IP address For example if IP address of current PC is 192 168 102 10 it will display 192 168 102 in list when first enabling SNMP Manager 3 1 1 Scan You may enter specific IP address and then click Scan button to search 3 1 2 Add IP Address Click Add button and it will pop up a window to ask for entering specific IP address Then click Apply button to add IP address Subnet Refer to Diagram 3 2 ie SNMP Manager System Settings Language Help Note Note IP address UPS name Address Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 Test Ups Name Address MAC address Change Automatically obtain IP address Use a
15. se wait 14 51 57 192 168 103 230 Upgrade is completed Diagram 4 11 NOTE If abnormal situation occurs during upgrade process the system will automatically re start the upgrade operation If this interruption occurs five times then system will automatically stop this operation At this time please check if LAN is working fine or not 4 2 4 Password management You may modify single password for one SNMP device or all passwords for all SNMP devices Refer to Diagram 4 12 14 iS SNMP Manager System Settings Language Help iE address UFS nama Address Basic Info IP settings Online upgrade Password management Static trap address 192 168 103 230 F Old password New password Confirm password Select device Select all Apply SNMP reset enable 182 168 103 a pane 14 49 03 192 168 103 230 Online successfully Add Diagram 4 12 Select Device Choose to change password for selected SNMP device on the window list Select all Choose to change passwords for all SNMP devices on the window list Operation step Enter original password new password and re enter new password to confirm Then click Apply button to complete password change NOTE The length of password is 8 15 digits if the password modifies operation for all SNMP devices all SNMP devices password must be consistent 4 2 5 Static trap address
16. t Static trap address 192 168 103 230 UPS name Address Note i l L IP address 192 168 103 230 MAC address 00 FF E7 00 12 F1 UPS name UPS name Address Address Note Note _ SNMP reset enable f f oe ant a T Output window 15 04 16 192 168 103 230 Online successfully Add Diagram 4 2 4 2 2 IP Setting Part 1 Change MAC address Step 1 IP list select from the need to modify the MAC address of the device then Change will be checked into Refer to Diagram 4 3 E SNMP Manager System Settings Language Help UPS name IP address Address Note 192 168 103 230 Test Ups Name Address Note SNMP reset enable 192 168 103 230 Beak Add Basic Info IP settings Online upgrade Password management f Static trap address MAC address 00 FF E Change Automatically obtain IP address Usea static IP address IP address 192 168 103 230 Subnetmask 255 255 255 0 Default Gateway 192 168 103 254 Apply Output window 14 16 08 192 168 103 230 Online successfully 14 23 30 Communication fails Please check your network 14 26 27 192 168 103 230 Wrong password entered Please retry to logon 14 26 47 192 168 103 230 Wrong password entered Please retry to logon Diagram 4 3 Step 2 Check the Change then enter the MAC address can be entered into a box Apply