        USER`S MANUAL
         Contents
1.                                32    15  TECHNICAL DATA     msequi                                         s  17  MAINTENANCE AND                                                             35       1  APPLICATION    LS1 1 electronic watt hour meters are destined for the direct measurement of active energy in  single phase power networks with the simultaneous display of measured quantities    They can be applied for settlement of accounts with electric power plants  for industrial process  control  for settlement of accounts with sub hirers    These watt hour meters are designed to be mounted on a wall    The housing enables to set a legalization leaden seal on the watt hour meter cover and a leaden  seal of the energy supplier on the terminal box    Thanks to built in communication interfaces  they can be applied as an element of energy ma   nagement systems    These watt hour meters have a 7 digit LCD display with additional graphic symbols  As stan   dard  there is also a lighting and pulsing red diode  LED  and interface for data transmission in  infrared     2  BASIC INFORMATION    LS1 1 electronic watt hour meters are resistant to a strong external magnetic field  e g  a neo   dymium magnet    A special designed antitheft protection has been applied in the mechanical construction  in the  electronic system and in the software     Protection of the construction     The frontal cover  having on the whole perimeter  internal and external projections enclosing  bilaterally 
2.     Electronic single phase watthour meter sr   X  X X  KT  X    Basic and maximal current   5 40 A  5  60  A  10  40      10  60  A       DB OG dB eei d eR dan i EK E M eM EE                  Input voltage   230 V  as per order                      Communication interface   optical port  optical port   pulse output  open collector   optical port   output of RS 485 type  Modbus   optical port   output of RS 232 type  Modbus   without optical port and interfaces        optical port radio module                                                                                     Accuracy class   accuracy clas 1       accuracy clas 2                  Tariffs    single tariff without internal clock  single or multi tariff with internal clock  two tariff withiexternal clocKV9                         urne tnr ecu teet rante kien tona                         Acceptance tests                                    RED                         8  with legalization             acc  to user s agreements        eseeceeeeeeceeseeeeeseeeeeeseeseeeaesaeeseeseeeaeeeeeeeeseeeeeeaeeeeseaeeeeeeeeeeee X              1   Custom made version  one must agree with the manufacturer  2    Concerns only the version LS1 1 X X 00 X X X  optical port   9   Concerns only the 1 tariff version with internal clock of LS1 1   X X XX X 1X    CODING EXAMPLE     The code  LS1 1 2 1 01 1 1 8 means   LS1 1   Electronic single phase watt hour meter with LCD display   2   Basic and maximal current  5  60  A  1   Input volt
3.    12  7 2  Way of configuration parameter change                    sss eene 13  8 ENERGY MEASUREMENT            iuiiia i 19  8 1  Recording of energy in                                                          19  6 2  Recording of total               c a eee tede       9  POWER REGISTERS               9 1  Averaged maximal power  9 2   Cumulated  DOWOL                     EH eei PU rca bas          19  10  END OF THE ACCOUNTING                                                                        19  11  AVAILABLE TARIFF GROUPS    Tieta Tanit group GIV Em  11 2   Tariff group G12 raii ede Ede e E hall  11 3  Tariff group  G12W    teer en EE rcr te cote alii  11 4  Tariff group  19    iude iii Galia alia ede tee dep       11 5  Tariff group C128 T                                 11 6  Tariff group C 12b       iss nc iis La                   11 7  Tariff group C 12W ante etl                 11 8  Tariff group  G228      e Rata  11 9  Tariff group  G 22D    ouem eer i E Det               11 10  List of holidays    12  OPTICAL INTERFACE  12 1  Watt hour meter registers in readout mode        12 2  Watt hour meter registers in programming and readout                                             26  13  RS 485 OR RS 232 SERIAL INTERFACE WITH MODBUS PROTOCOL  OPTION         27  13 1  List of serial interface parameters                       ii 27  13 2  Map of watt hour meter registers                      nennen 28  14  INTERNAL CONTROL CLOCK  for options with external clock    
4.    Menu of tariffs    E     t Me  FE Selection of the    tariff group    tr       i Range of changes   Set  gt  25 I    Scroll eu i Piter  G12u  tariff G12w     F      C12A  tariff C12A              Scroll     C12b  tariff C12B  pnr ORE C12u  tariff C12W  Set G13   tariff G13           C22A  tariff C22A  Mi te      Scroll C22b  tariff C22B  USEr  user s tariff  Set     lt          external clock  control                Setting of time    Range of changes     He    30D Scroll  for hours  00   23    H3 ge   D Scroll for minutes  00   59       Hi    302 Scroll            HH ei    2 Scroll      Selection of tariff zones t1  t2  t3  t4  for tariff hours     rAnt  rAn2  rAn3  rAnd     rAn1  time interval since H1 till H2  rAn2  time interval since H2 till       rAn3  time interval since      till H4  rAn4  time interval since      till H1    Range of changes                                     zone T1  t2   zone T2  t3   zone T3   t4   zone   4           E  soro            Ci cro  rAn1  rAn2  rAn3  rAn4   these parameters are only  Set C accessible in the user s tariff group  USEr   e  3         Ar    t     Scroll    i  s Selection of zone for   i       Sat  Sathurd  cr r at  Sathurdays  2 Ht         Scroll Sun   Sundays  Hol  Holidays  Set al           Range of changes   5 Ln Ec D Scroll Cur   as in the select tariff group  Set t1   tariff zone T1  e   t2   tariff zone T2                LI t3   tariff zone T3  rcu ec 2 Scroll t4   tariff zone T4       Sat  Sun   these parameters a
5.   7 CHANGE OF WATT HOUR METER CONFIGURATION    The change of watt hour meter configuration is possible in the programming mode  SET   The  watt hour meter is switched in the SET mode by means of the button     7 1 Button    The watt hour meter has one button  By means of this button set on the scroll position in the  normal watt hour meter operation  it is possible to review parameters described in the point 6   In this position  the button can be leaden sealed  To transit to the SET position  one must re   move the seal if exists and turn the button of 90   to the right  The table 1 presents the button  functions     SET                      rr omoo       SCROLL position SET position    Fig  11 Available button positions    12    Button functions Table 1    Button Working mode Function  SCROLL REVIEW Review of parameters  SCROLL PROGRAMMING   Selection and change of programmable parameter values             SCROLL   gt  2 sec   PROGRAMMING   Automatic incrementation of the parameter value  SET     2 sec   REVIEW Entry into the parameter configuration mode  SET PROGRAMMING   Selection of the parameter   SET     2 sec   PROGRAMMING   Acceptation of the parameter group change                      The watt hour meter transits from the parameter review mode  or from the configuration mode  to the normal operation mode after 30 sec  from the last button use     7 2  Service algorithm    The scheme of the main menu of the watt hour meter configuration is presented on the fig  10a  
6.   LCD  with graphical symbols     Upper hanger   metallic element fixing the watt hour meter to the power box or the watt hour  meter niche     Two function button   review and setting of watt hour meter parameters     Optical link   enables the readout and write of data from and to the watt hour meter   Screw   fixes the shield  7  and is adapted to seal with lead by the power plant     Shield of the terminal box     Shield of the watt hour meter   It is fixed to the base by internal catches and two screws  10      LED diode   generates light pulses with a defined time constant  imp kWh                                  10  Screw          amp              10  Screw  11  Hole i         11  Hole    13  Interface link          12  Terminal box    Fig  1b Watt hour meter design   View of terminals after removing the terminal  shield  7     10  Fixing screws   to fix the shield  8   they are adapted to seal with lead by the producer or to  put the verification mark    11  Fixing holes   with the metallic upper hanger  3   they define the fixing points of the watt hour  meter in the power box  cabinet  or the niche for watt hour meters    12  Terminal box   enables the connection of measuring circuits  13  Interface link   to connect interface wires    5  INSTALLATION    5 1 External dimensions and fixing way  Watt hour meter overall dimensions are presented on the fig  2   The LS1 1 watt hour meter is fixed on the wall     Housing dimensions  206 x 120 x 65 mm  The box has screw t
7.   Period of time    Table 5       Summer     1 April   30 September     Winter     1 October   31 March        Ante meridian peak  T1     700   4300    790  1300       Post meridian peak  T2     199   2200    169   219       Remaining hours of  the 24 hours  zone  T3           13   1900  2200  700       139   1600  2400  700       Legal day offs  Saturdays and Sundays are included in the 24 hours  zone to the third zone  as remaining    hours of the 24 hours  zone     20    11 5  Tariff group C12a    24 hours  zone    Table 6    Period of time       Summer    Winter     1 April   30 September   1 October   31 March        Peak zone  T1     800   4400  2000   2100    800   1100  17    21        Extrapeak zone  T2           11    20   2400 _ go       11    179  200   goo       Holidays are includ to the zone depended on the setting of Hol parameter in tAriFF    11 6  Tariff group C12b    24 hours    zone    Table 7  Period of time        1 January   31 December        Daily zone  T1        Night time zone  T2        Notations        600   7   H   139   1400  H   15    16   H   220   2300    4          Holidays are included to the zone depended on the setting of Hol parameter in tAriFF    11 7  Tariff group C12w    24 hours    zone    Table 8    Period of time        1 January   31 December        Daily zone  T1     2    4       Night time zone  T2        Notations         600   700        13    1400  H   1500   16       2290   2300    4       1       Saturdays and Sundays      
8.   included In the 24 hours  zone  to the second zone   night time  Holidays are included to the zone depended on the setting of Hol parameter in tAriFF    21    11 8  Tariff group C22a Table 9    Period of time  I  Il  XI  XII Ill  X IV  IX V  VI  VII  VIII  800   1190 800   1100 800   1100 800   1100  16   2499 1800   2499 1900   2190 2090   2190  2100   800 2100  goo 2100   800 2100   800  119    1699 1190   1890 11    1900 1190   2099  Holidays are included to the zone depended on the setting of Hol parameter in tAriFF       24 hours  zone       Peak zone  T1        Extrapeak zone  T2                       11 9  Tariff group C22b Table 10    Period of time   1 January   31 December        24 hours  zone       Peak zone  T1  600   2400  Extrapeak zone  T2  21    600    Holidays are included to the zone depended on the setting of Hol parameter in tAriFF                11 10  Liste of holidays  Following days are implemented in the watt hour meter  as permanent holidays     statutorily free of work  1st January   New Year   1st May   International Holiday of the 1st of May   3rd May   National Holiday of 3rd May   15th August   Assumption   1st November   All Saints Day   11st November   Independence Day     25th December    First Day of Christmas   26th December    Second Day of Christmas     Movable feasts  The first day of Easter  Corpus Christi     12 OPTICAL INTERFACE  Parameter set of the optical link of the LS1 1 watt hour meter       conformity with the standard EN620
9.   no  period closure HE S  yes  dd Day of automatic closure of the 0   Eob accounting period       t  Hour of automatic closure of the 00 23  accounting period Usi  ta Minute of automatic closure of the 00 59  accounting period i  88   t  ASCII 8N1         t  ASCII 7E1  cS Working mode      t ASCII 701            RTU 8N2   8E t  RTU 8E1  podbus        t  RTU 801         t  RTU 8N1  Aide Address 1 297  b 4 8  4800 bit sec  d   Baudrate 9 5  9600 bit sec  19 2  19200 bit sec  CLER  fle Cancelation of the magnet interferen    no  no  ce and or the cover opening HE S  yes  15 03  15 min  subrange 3 min  15 05  15 min  subrange 5 min  15  15  15 min  subrange 15 min  Poutc PR Mode of power averaging 39 05  30 min  subrange 6 min      10  30 min  subrange 10 min  0 30  60 min  subrange 30 min  60  102  60 min  subrange 12 min  0 20  60 min  subrange 20 min  0 60  60 min  subrange 60 min       18       8 ENERGY MEASUREMENT    8 1 Recording of energy in tariffs    In any time  the watt hour meter accounts the energy in one of the tariffs  When the register reaches  its maximal value 999 999 9 kWh  it is automatically reset and the account begins from zero     8 2 Recording of total energy  The recording of the total energy consists in storing the total energy consumption in one register     independently of the tariff  When the register reaches its maximal value 999 999 9 kWh  it is  automatically reset and the account begins from zero     9 POWER REGISTERS    9 1 Averaged maximal po
10.  After pressing and hold down the button during at least 2 sec   in the SET position  it is possible  to program parameters  The transition between parameters is made by means of the button on  the SET position  The table 2 comprises the parameter description  The return to the normal  operation follows after reviewing of all visible groups of parameters or automatically  after the  laps of 30 sec  since the last button pressing    Caution  same parameters or paremeter settings can be invisible  inaccessible  depending   on the watt hour meter version and its current configuration        Main menu of watt hour meter  configuration             Main menu  Set    2s          Watt hour meter o Pt    _Scroll_     Menu of the  in the current zone         Set   2s   optical interface    Set     Scroll     x  Do     t rri    E Menu of tariffs    Set  gt  2s  Set      er      Scroll Menu of  L L                 Date Time  Set  gt  2s change  Set    M    COE Scroll Menu of  Lou     accounting  Set  gt 2s   period closing  Set    b    Scroll                                  Menu of the             Senn  Set   2s   serial interface    Set   3           Scroll Menu of interference  TI III                                 x by a magnet     Set  gt  2s   cover opening    Scroll                n mu Pa r                  Menu of power  LLL            Set  gt  2s averaging          Set       Fig  12a Watt hour work algorithm   Main menu    13    Menu of the    optical interface          On Off 
11.  format     Current date  in the year month day format     Energy in zone T1    Energy in zone T2  if occurs in the set tariff group     Energy in zone T3  if occurs in the set tariff group     Energy in zone T4  if occurs in the set tariff group     Total energy    Closing time of the accounting period  in the hour minute format     Closing date of the accounting period  in the year month day format     Energy in zone T1 at the end of the previous accounting period    Energy in zone T2 at the end of the previous accounting period  if occurs in the  set tariff group     Energy in zone T3 at the end of the previous accounting period  if occurs in the  set tariff group     Energy in zone T4 at the end of the previous accounting period  if occurs in the  set tariff group      Total energy at the end of the previous accounting period   Symbol of the set tariff group     The start of information review  i e  the transition from the energy display mode in the current  zone  follows after pressing the button in the SCROLL position    Successive information are sequentially accessible  After 30 seconds since the last button  pressure  the watt hour meter returns to the normal working mode  Depending on the option  and watt hour meter configuration  the number of accessible information in the review mode  can be smaller    6 1 VIEW OF THE LCD DISPLAY    Index of active Index of total Symbols of Symbol of review Index of extra       energy    10       energy value time zones programmin
12.  of closure possibility  e g  because of a lack of supply  the closure process  will be carried out after the supply voltage recovery   After each closure of the accounting period  it is increased by one closure counter   Note  It is recommended to close the accounting period during the watt hour meter instal   lation  so as to memorize initial values of energy already counted   If the closure has been carried out in the day in which the automatic closure should  occur  then the automatic closure will be cancelled on this day     19    11 AVAILABLE TARIFF GROUPS    11 1 Tariff group G11    The energy is counted during the whole time in the T1 zone     11 2  Tariff group G12    Period of time    Table 3       24 hours  zone     1 January   31 December        Daily zone  T1     1 2    3 4       Night time zone  T2           Notations    H   600   700        13    1400   H   1500 169   H   22     2300        Holidays        included to the zone depended on the setting of Hol parameter in tAriFF     11 3  Tariff group G12w    1    Period of time       Table 4       24 hours  zone     1 January   31 December        Daily zone  T1        Night time zone  T2           Notations    H   600   700       13    1400       159   1699    3    H  22    2300    Holidays are included in the zone depended on the setting of Hol parameter in tAriFF       Saturdays and Sundays are included In the 24 hours    zone to the second zone   night time zone    11 4  Tariff group C13    24 hours    zone  
13.  word       30       0    65535       Number of erasings of interference by a strong magnetic field and or the  index of cover opening       Meaning of bits in the Status register  register 4000  Table 16    Description    Signalling of voltage in phase  0   voltage under 0 9 Un  1   voltage over 0 9 Un       Always 0       Always 0       Current time zone  Bits  54 3  001 T1 zone  0 10  T2 zone  0 11  T3 zone  100   T4 zone       Decimal places for power   Bits  7 6  0 0   without decimal places  0 1   1 decimal place  10   2 decimal places       Decimal places for energy   Bits  9 8  0 0   without decimal places  0 1   1 decimal place  10   2 decimal places       Prefix of the unit for energy and power  Bits 11 10   0 0 lack   0 1 k   1 0 M       Interference by a strong magnetic field  0   lack  1   exist       Opening of the watt hour meter cover  0   cover closed  1   cover open       Not used       Error  0   no errors  0   one must check the error register          31    Meaning of bits in the error register  register 4046  Table 17  Description    Detection of an erroneous contents   energy in zone T1       Detection of an erroneous contents   energy in zone T2       Detection of an erroneous contents   energy in zone T3       Detection of an erroneous contents   energy in zone T4       Detection of an erroneous contents   total energy       Detection of an erroneous contents   energy in zone T1 in the previous  accounting period       Detection of an erroneous conten
14. 5 11 05     Hour and date of the beginning of interference  by a strong magnetic field       0000000327    Duration of interference by a strong magnetic field  sec        Index of cover opening  interference into the watt hour meter    0    There was no opening          There was or there is an opening             Number of register erasing of interference by a strong  magnetic field and or housing opening        25    Description of the register   watt hour meter errors Table 12    Description    o    Detection of erroneous contents   energy in zone T1  Detection of erroneous contents   energy in zone T2  Detection of erroneous contents   energy in zone T3  Detection of erroneous contents   energy in zone T4  Detection of erroneous contents   total energy                   Detection of erroneous contents   energy in zone T1 in the previous account period  Detection of erroneous contents   energy in zone T1 in the previous account period  Detection of erroneous contents   energy in zone T2 in the previous account period  Detection of erroneous contents   energy in zone T3 in the previous account period  Detection of erroneous contents   total energy in the previous account period   Not used   Incorrect value of the error register                     O O1 A ON                           12 2 Watt hour meter registers in the programming and read out mode  List of watt hour meter registers with identifiers and example of contents in case  of readout and or data write in the progr
15. 56 21     manufacturer identifier LML     baud rate identifier 4     watt hour meter identifier LS11 LUMEL     transmission protocol mode C of transmission     transmission initialization 300 baud     available baud rates 300  600  1200  2400  4800 baud    character format acc  to ISO 1177 7E1     write interlock button secured by a leaden seal    The optical interface in the watt hour meter enables the realization of following functions     data readout from the watt hour meter      write of selected parameters to the watt hour meter      closure of the accounting period     The write of parameters and closure of the current accounting period are possible after breaking  the leaden seal and setting the button on the SET position     22    To unlock or lock the write  one must      press the SET button in a time longer than 2 sec      pressing the SET button  transit to the    oft    menu      by means of the SCROLL button unlock the  S  t on    write or lock the    566 of F    write      pressing the SET button in a time longer than 2 sec  accept the change      pressing the SET button  exit from the SETUP procedure    The locking of the write follows automatically after a 5 minutes  lack of communication through  the optical link     12 1 Watt hour meter registers in the readout mode    The list of registers with identifiers and the example of contents in case of data readout is pre   sented in the tables below     Note  Depending on the option and watt hour meter configura
16. 99999999    Active energy in zone T3 at the end of the previous  accounting period  KWhx100        MS word       LS word    0    99999999    Active energy in zone T4 at the end of the previous  accounting period  KWhx100        MS word       LS word    0    99999999    Total active energy at the end of the previous  accounting period  KWhx100        word    0    65535    Counter of accounting period closures       word    2001    2035    Year of accounting energy closure       word    101    1231    Date of accounting period closure in format   month   100   day       word    0    2359    Time of accounting period closure in format   hour   100   minute       word    0    700    The highest value of averaged power  kWh x10        word    2001    2035    Year of the highest value of averaged power occurrence       word    101    1231    Date of the highest value of averaged power occurrence  in format  month   100   day       word    0    2359    Time of the highest value of averaged power occurrence  in format  hour   100   minute       word    0    455    The highest value of averaged power in the previous  accounting period        word    2001    2035    The year of the highest value of averaged power occurrence  in the previous accounting period       word    101    1231    The date of the highest value of averaged power  in the previous accounting period in format   month   100   day       The time of the highest value of averaged power  in the previous accounting period 
17. ELECTRONIC SINGLE PHASE  WATT HOUR METER  WITH DIGITAL COMMUNICATION    LS1 1 TYPE       USER S MANUAL CE    CONTENTS             APPLICATION e li ondata Ila ili ali li i liti 5  2  BASIC INFORMATION nd  3  WATT HOUR METER                                               SEE ous Asus ma RD ea RP            6  4  WATT HOUR METER DESIGN                      esee nnne nnns anneanne nanan 6  Sa INSTALLATION  ERR 7  5 1  External dimensions and fixing way              5 2                                             Ltd coenae      Aia        9  6  DISPLAYED INFORMATION           2                 ores eos auae      10  6 1  View of LCD                                                            10  6 2  Displayed energy                  iii 11  6 3  LED Pulso OUP                        ici iena 11  6 4  Signalling of phase voltage presence                     iii 11  6 5  Signalling of the active tariff  time 20                                                    11  6 6  Signalling of energy counting                    sess eee        11  6 7  Signalling of review  parameter programming or interference with a magnetic field      11  6 8  Signalling of housing opening  interference in the watt hour meter                              12  6 9  Signalling of extra information                                         rene 12  7  CHANGE OF WATT HOUR METER                                                                                 12  DUET MM                                               
18. TORS   m ACCESSORIES FOR MEASURING INSTRUMENTS   m MEASURING SYSTEMS  ENERGY  HEAT  CONTROL    m CUSTOM MADE PRODUCTS    WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF   m ALUMINIUM ALLOY PRESSURE CASTINGS   m PRECISION ENGINEERING AND THERMOPLASTICS PARTS  m PRESSURE CASTING DIES AND OTHER TOOLS    QUALITY PROCEDURES    ACCORDING TO ISO 9001 AND ISO 14001 INTERNATIONAL REQUIREMENTS   All our instruments have CE mark and respect RoHs Directives   For more information  please write to or phone our Export Department    LS1 1 07A    LUMEL    Lubuskie Zaktady Aparat  w Elektrycznych LUMEL S A   ul  Sulechowska 1  65 022 Zielona G  ra  Poland    Tel    48 68  329 51 00  exchange   Fax   48 68  329 51 01  e mail lumel lumel com pl  http   www lumel com pl       Export Department    Tel    48 68  329 53 02 or 53 04  Fax   48 68  325 40 91   e mail  export lumel com pl    
19. USEr tariff group        T4 zone  Selection of tariff zone for Saturdays      _ __     Parameter accessible only forthe      715  the selected tariff group  SAE USEr tariff group  The selection of          1 zone     Cur    parameter  causes that the te  T2 zone  watt hour meter counts the energy   t3       zone  according to settings of   rAn1    4      V  T4 zone  parameters   Selection of tariff zone for Sundays  Cur aginth lected tariff  Parameter accessible only forthe   1715 In the selected tariif group  Sun USEr tariff group  The selection of          1 zone    Cur  parameter  causes that the te  T2 zone  watt hour meter counts the energy    amp  3       zone  according to settings of   rAn1    4          TA zone  parameters   Selection of tariff zone for Holidays    wr  as in the selected tariff group  Hol The selection of   Cur    parameter  t i  T1 zone       causes that the watt hour meter te  T2 zone  counts the energy in the zone t3       zone  resulting from the set tariff        T4 zone          17    List of configuration parameters    Table 2  continuation                                                                 Main Parameter Parameter description Range of parametr changes  menu symbol       Current year 200 1 2035  dn Current month       T dd Current day 01 31                 th Current hour 80   23  tn Current minute 00   59         Automatic change of the of F  turned off  winter summer time on  turned on  tob Instant execution of the accounting  o
20. age  230 V  01   Communication interface  optical port and output of O C type  1   Accuracy class  1  1  Single tariff version  8   Delivered without a legalization certificate    34    17  MAINTENANCE AND WARRANTY    The LS1 1 watt hour meter does not require any periodical maintenance  In case of some  incorrect operations     1  After the dispatch date and within the period stated in the warranty card  One should return the watt hour meter to the Quality Inspection Dept   If the instrument has been used in compliance with the instructions  we  warrant to repair it free of charge   The disassembling of the housing causes the cancellation of the granted warranty     2  After the warranty period   One should send the instrument to repair it in an authorized service workshop   Spare parts are available for the period of five years from the date of purchase     Our policy is one of continuous improvement and we reserve the  right to make changes in design and specifications of any products    as engineering advances or necessity requires and revise the above  specifications without notice        35    SALES PROGRAM MEASUREMENT    m DIGITAL and BARGRAPH PANEL METERS CONTROL  m MEASURING TRANSDUCERS RECORDING  m ANALOG PANEL METERS  DIN INSTRUMENTS    m ANALOG and DIGITAL CLAMP ON METERS   m INDUSTRIAL and HOUSEHOLD CONTROLLERS      CHART AND PAPERLESS RECORDERS   m POWER CONTROL UNITS and INVERTERS      LARGE SIZE NUMERIC and ALPHANUMERIC DISPLAYS   m AUTOMOTIVE DASHBOARD INDICA
21. amming mode   Table 13  Identifier Format of   ASCII   ASCII charac  Parameter    charac    ters  example  ters  of contents     12 34 56 Current time and date   25 11 02   1 Automatic time change winter summer acc  to fig 10c  AbcDeFgHiJ User s identifier  02110001 Factory number    7 Power averaging time and number of subperiods    like in table 11     Day and time in which the account  17 13 55 period is closed    day  00        28        05 Kind of tariff group  like in table 11     07 20  10 12 Variable hours for tariffs  G12  G12w  C12b  C12w   22 30  23 30 USEr                            22112 Configuration of the serial link  mode  address  baud rate    like in table 11        Register erasing of interference by a strong  magnetic field and cover opening                 26    Table 13  continuation     1010111 Selection of the time zone for tariff hours    Saturdays  Sundays and holidays  only for USEr tariff    1 st character     selection of zone for the hour interval since H1 till H2   2 nd character     selection of zone for the hour interval since H2 till H3   3 rd character     selection of zone for the hour interval since H3 till H4   4 th character     selection of zone for the hour interval since H4 till H1       Meaning of 1   4 characters     0      T1 zone          T2 zone   2         zone     3        4 zone    5 th character   selection of zone for Saturdays  only for USEr tariff   6 th character   selection of zone for Sundays  only for USEr tariff   7 
22. and tightly the base wall  unabling the interference with a tool inside the watt hour  meter      The cover is fixed to the base by two screws  what gives a durable junction secured additio   nally by leaden seals      The shield of the terminal box additionally presses down the cover and protects the fixing  screws by leaden seals      The junction of the cover and the base is sealed  what protects against the infiltration of fluids  and dust     Electronic and programmed protection     Sensor of mechanical interference in the watt hour meter  The lift of the watt hour meter frontal  cover causes the sensor operation  and the existed interference is signalled on the display  Ad   ditionally  the date and the interference duration are stored in the watt hour meter memory      Sensor of the interaction by a strong magnetic field  e g  a neodymium magnet  The application  of a strong magnetic field to the watt hour meter causes the sensor operation  and the existed  interference is signalled on the display      The number of mechanical interference and interactions by a magnetic field is durably recorded  in the watt hour meter     Protection against the switching of power network wires   The watt hour meter counts the energy when interchanging network wires  The energy is acco   unted regardless of the flow direction  The shield of the terminal box can be optionally made of  a transparent plastics enabling a visual inspection of the electrical connection correctness with  the 
23. curacy class acc  to the version code    32    Working temperature range  Storage ambient temperature    Power consumption      in the voltage circuit     in the voltage circuit for a watt hour  meter with RS 485  RS 232  interface or a radio module     in the current circuit    Starting current    Detection level of the  voltage presence    Pulse constant of the LED diode  Readout field   Communication interfaces  Output of energy pulses   Pulse constant of O C  output  Tariff input    Available tariffs    Number of tariff zones    Resistance against external  permanent magnetic field    Resistance against surge voltages    Reaction of the watt hour meter  to voltage decays    Clock accuracy    Protection degree ensured  by the housing    Battery life time  External dimensions  H x W x D   Weight      95    65  C    35    80  C     lt  8 VA 0 3 W     lt  7 VA 1 3W   lt  0 015         0 004       0 90 U    3200 imp  kWh or another  to agree    special LCD display   acc  to the version code   output of O C  type  passive acc  to EN 62053 31  3200 imp  kWh or another  to agree    1 input  2 tariffs   switched voltage U     G11  G12  G12w  G13  C12a  C12b  C12w  C22a   C22b  1 tariff programmed by the user    from 1 to 4    640 kA m  4 kV    Storage of data and the watt hour meter state  after the decay in the FRAM non volatile memory   storage durability  min  15 years    t 2s day    IP 54   minimum 10 years  203 x 122 x 65 mm  ca  0 75 kg    33    16  ORDER CODES Table 18     
24. e 2                                                                   isi pog Parameter description Range of parametr changes  Possibility of write through the off  disabled          set optical interface on  enabled  G 1 i tariff group G11  G te  tariff group G12  G teu  tariff group C12w     12  tariff group C12a  te Selection on the tariff    100  tariff group C12b  C feu  tariff group C12w  G 13  tariff group G13  CeehR  tariff group C22a  Ceeb  tariff group C22b  USE  User s tariff  Hi ii    G12  G12w  86  08   67  08 or optionaly for USEr  He T2 time for tariff groups G12  G12w  13 00   4  00 or optionaly for USEr  C12b  C12w  USEr  H3 T3 time for tariff groups G12  G12w  15 00   6 00 or optionaly for USEr  C12b  C12w  USEr       5 db CUM    G12  G12w    22 00  23 000r optionaly for USEr  Selection of tariff for the time interval          T1 zone  An  since H1 till H2  te  T2 zone  Parameter accessible only in the t 3       zone  Ae  EE USEr tariff group             zone  Selection of tariff for the time interval          T1 zone  r  ae since H2 till H3  te  T2 zone  Parameter accessible only in the t 3       zone  USEr tariff group        T4 zone  Selection of tariff for the time interval          T1 zone  eAn3   since H3 till H4  te  T2 zone  Parameter accessible only in the t 3       zone  USEr tariff group        T4 zone  Selection of tariff for the time interval           T1 zone  c Hass since H4 till H1  te  T2zone  Parameter accessible only in the t3       zone  
25. e measured energy     6 7 Signalling of review and parameter programming or interference by a mag   netic field     Fig  8 Index of parametr review programming or field interference    When the user reviews parameters in the SCROLL mode or enters in the SET programming  mode  the symbol presented on the fig 8 is visible on the display     11    The flickering symbol signals a strong magnetic field interference  If the watt hour meter is under  the influence of this field  then the index is lighting in a permanent way  If the magnetic field duration  was longer than 30 seconds and the watt hour meter is not under its influence  the index flickers  till the time of erasing register of interference by the magnetic field through the optical link     6 8 Signalling of housing opening  interference inside the watt hour meter     The lift of the frontal cover  interference inside the watt hour meter  is signalled on the display  by the flickering inscription  OPEN  alternatively with the current readout  In the same time  the  date and the interference duration are recorded in the watt hour meter memory        E    1    ri  2 kW h    c    Un  Ax          lai       Fig  9 Screen signalling the housing opening    6 9 Signalling of additional information    A    Fig  10 Index of additional information    The visible signal above on the display signals that the write through the optical link is allowed   However  the flickering symbol signals the incorrect work of the watt hour meter   
26. erminals with 6 5 mm internal  diameter to connect to the power network  and auxiliary circuits with a wire up to 1 5 mm   cross section           61 3                                                    39 5             8            0c                                                                                                                                                                                        97             104  122                               EVOL  6   6                      8 99      8   OrL    Fig  2 Watt hour meter overall dimensions    5 2 Connection diagrams          Pulse  output                 FX                                                                                       L    L1  N N  Single tariff watt hour meter for direct Watt h ith pul  connection att hour meter with pulse output  Communication Communication  interface interface   RS 485 RS 232  modbus modbus                   B Tx                                                 L1 L1  N N  Watt hour meter with an RS 485 communication Watt hour meter with an RS 232 communication  interface and Modbus protocol interface and Modbus protocol  Tariff  input  21                         L1  N    Two tariff watt hour meter with an external clock       Fig 3 External connection diagrams of the watt hour meter    6  DISPLAYED INFORMATION    It is possible to readout following information on the LCD display     m               Energy in the current zone    Current time  in the hour minute
27. g or information  field interference       Value of the    d   1       C    Wo    measured quantity    Load index Units of the  Voltage index  arrows are whirling if the measured quantity    energy is counted     Fig  4 LCD display          6 2 Displayed energy    In the LS1 1 watt hour meter  the energy is displayed in kWh  with one decimal place  The  counter register has 7 digits     6 3 LED pulse output  The red lighting LED diode is the index of the energy flow   The frequency of light flashes is proportional to the current energy flow     6 4  Signalling of the phase voltage presence    L1    Fig  5 Index of the phase voltage presence    The L1 index signals the presence of the phase voltage In case when its value exceeds 0 9 Un    6 5 Signalling of the active time zone  tariffs      gt  Ti T2      T4    Fig  6 Tariff indexes    The active tariff zone is indicated by one of the symbols  e g  for the first tariff the T1 symbol is  displayed  For the total energy  all accessible tariff symbols together with the    sum mark are  displayed     6 6 Signalling of energy accounting  bw   Fig  7 Index of energy accounting    For signalling the energy accounting  an index composed of 3 arrows is accessible  If the energy  is accounted  two arrows are shifting  giving the effect of the index turning round  If the watt hour  meter does not account the energy  all the 3 arrows are visible  they do not turn round   The index  turning round speed is constant and does not depend on th
28. ifier   ASCII  charac   ters     Format of  ASCII charac   ters  example   of contents     010301    Table 11  continuation     Parameter    Watt hour meter status   1 st character   Signalling of voltage in the phase        U lt 0 9 Un  1    U20 9 Un   2 nd character   Always    0     3 rd character   Always    0     4 th character   Current time zone    1   1 stzone T1     2    2 nd zone T2     3      3 nd zone          4    4 th zone   4  5 th character   Signalling of cover opening     0    or    1      6 th character   Signalling of magnetic field interference     0    or  1         01101000  00011000    Register of watt hour meter errors  see table 12      0    or    1           7    Time of power averaging and number of subperiods    0    15 min  3 min subperiod           15 min  5 min subperiod      2     15 min  15 min subperiod      3      30 min  6 min subperiod    4    30 min  10 min subperiod    5    30 min  30 min subperiod    6    60 min  12 min subperiod      7      60 min  20 min subperiod    8    60 min  60 min subperiod       17 13 55    Day and time in which the account period is closed    day    00      automatic closure is off  day    01         28      hour    00         23      minute    00         59           Tariff groups       00      G11      01      G12      02      G12w      03      C12a      04      C12b      05      C12w      06      G13      07      C22a      08      C22b      09      USEr  user s tariff      10      controlled by the externa
29. in format   hour   100   minute             0    65535       Cumulated power  kW x 10        29    Table of watt hour meter 16 bit registers Table 15  continuation     Way of power averaging   0   15 min  3 min subperiod    15 min  5 min subperiod    15 min  15 min subperiod    30 min  6 min subperiod    30 min  10 min subperiod    30 min  30 min subperiod    60 min  12 min subperiod    60 min  20 min subperiod   8   60 min  60 min subperiod          Time of the automatic accounting period closure in format   hour   100   minute       0    28    Day of the automatic accounting period closure       0    32000    Constant of pulse output    imp kWh        Tariff group     G11    G12     G12w     C12a     C12b     C12w     G13     C22a     C22b     USEr  user s tariff   0   external clock control     gt  0                                          word    10    X    Number of the program version  x10        word    0    65535    Register of watt hour meter errors       description in table 17        word    2001    2035    Year of the first beginning of interference  by a strong magnetic field       word    101    1231    Month and day of the first beginning of interference  by a strong magnetic field       word    0    2359    Time of the first beginning of interference  by a strong magnetic field       MS word    LS word    0     29 1     Duration of interference by a strong magnetic field       word    0   1    Index of cover opening  interference in the watt hour meter       
30. l clock       24       07 20  10 12   22 30  23 30       Variable hours for tariffs  G12  G12w  C12b  C12w  USEr       1010114    Table 11  continuation     Time zones for Saturdays  Sundays and holydays   only for USEr tariff     1st character   zone for hour interval since H1 till H2   2 nd character   zone for the hour interval since H2 till H3  3 rd character   zone for the hour interval since H3 till H4  4 th character   zone for the hour interval since H4 till H1       Meaning of 1   4 charac   0   T1 zone          T2 zone   2         zone     3      T4 zone       5 th character   Zone for Saturdays  only for USEr tariff   6 th character   Zone for Sundays  only for USEr tariff   7 th character   Zone for holidays       Meaning of 5   7 characters     0      as in the selected tariff group     1   T1 zone   2    T2 zone     3           zone   4    T4 zone    In case when choosing    0     time zones are defined acc  to the  chosen tariff group  see the description of tariff zones in Table 2       Configuration of the serial link  mode  address  baud rate    1 st character   mode           ASCII 8N1      2      ASCII 7E1      3      ASCII 701      4      RTU 8N2    5    RTU 8E1    6    RTU 801      7     RTU 8N1  2  3  4 th character   address   001     247    5 th character   baud rate      0      4800 baud      1      9600 baud      2     19200 baud       No of the program version       Automatic change of winter time summer time     0      off         on       10 12 2
31. re only accessible  Set in the user s tariff group  USEr        15    Fig  12e Algorithm of the watt hour meter work   menu of tariffs       Menu of serial Setting of serial  interface interface parameters        Range of changes   Working mode   Set  gt  25 rS A8n1  ASCII 8N1  rS A7E1   ASCII 7E1  rS A701   ASCII 701  rS r8n2  RTU 8N2  rS r8E1  RTU 8E1  rS r801  RTU 801  r  r8n1  RTU 8N1    Device address  Adr   001   247    Baud rate  bd4 8  4800 bps  bd9 6  9600 bps      bd 19 2   19200 bps                  Fig  12f Algorithm of the watt hour meter work   menu of serial interface       Menu of interference erasing          Erasing of interference by the  magnetic field and or cover opening  Change of ranges   oFF    lack of operation  on   erasing          Fig  12g Algorithm of the watt hour meter work   menu of interference by a magnet  and cover opening    Menu of power  averaging          Selection of averaging time and     number of subperiods for the  maximal mean power   Range of changes    PA 15 03  15 min   subperiod 3 min  Set gt  2s      15 05  15 min   subperiod 5         PA 15 15 15 min   subperiod 15 min  PA 30 06  30 min   subperiod 6 min  PA 30 10   30 min   subperiod 10 min  PA 30 30   30 min   subperiod 30 min  PA 60 12   60 min   subperiod 12 min  PA 60 20   60 min   subperiod 20 min  PA 60 60   60 min   subperiod 60 min                Fig  12h Algorithm of watt hour meter work   menu of power averaging    16       List of configuration parameters    Tabl
32. scription  number    word 0    65535   Watt hour meter status       description in table 16   word   2001    2035   Current year  word 101    1231   Current date in format  month   100   day  word 0  2359   Current time in format  hour   100   minute  MS word   05010001      Serial number  LS word   35129999  word   0x00    OxEE   User s identifier  1 and 2 character   word   0x00               User s identifier     and 4 character                                   word   0x00    OXEE   User s identifier  5 and 6 character    word   0x00    OXEE   User s identifier  7 and 8 character    word   0x00    OXEE   User s identifier  9 and 10 character   MS word   0    99999999   Active energy in zone T1  kWhx100   LS word  MS word   0    99999999   Active energy in zone T2  kWhx100   LS word  MS word   0    99999999   Active energy in zone T3  kWhx100   LS word  MS word   0    99999999   Active energy in zone T4  kWhx100   LS word  MS word   0    99999999   Total active energy  LS word  MS word Reserved  LS word                                                 MS word Reserved  LS word  MS word Reserved  LS word  MS word   0    99999999                Active energy in zone T1 at the end of the previous  LS word accounting period  KWhx100                    28    Table of watt hour meter 16 bit registers Table 15  continuation     MS word    LS word    0    99999999    Active energy in zone T2 at the end of the previous  accounting period  KWhx100       MS word       LS word    0    
33. th character   selection of zone for holidays          Meaning of 5   7 characters     0      as for the selected tariff group     1   T1 zone     2     T2 zone   8         zone   4    T4 zone  In case when    0    is chosen  time zones are defined acc  to    the selected tariff group  see the description of the tariff  zones in Table 2                 Notations  R   only for readout  R W   readout and write    Note  In case of a watt hour meter configuration  when the given parameter is not used   the caractere code       minus  is returned     13  RS 485 or RS 232 SERIAL INTERFACE WITH MODBUS PROTOCOL  13 1 Set of serial interface parameters     e identifier OxAO   e watt hour meter address 1    247   e baudrate 4800  9600  19200 bod  w    e working mode ASCII  RTU    e information unit ASCII  8N1  7E1  7O1   RTU  8N2  8E1  801  8N1    e maximal response time 600 ms     Factory settings  address  1  baud rate  9600 baud  RTU mode  8N2   LS1 1  watt hour meter realizes following protocol functions     Table 14    Readout of n registers          17   Identification of the slave device    27    13 2 Map of watt hour meter registers    Data are placed in 16 bit registers  Process variables and watt hour meter parameters are placed  in the register address space in a way depending on the type of the variable value     Bits in the 16 bit registers are numbered from the youngest to the oldest  b0 b15    Table of watt hour meter 16 bit registers Table 15    Register    Parameter De
34. the write possibility       Scroll        throught the optical interface  Scroll   Range of changes   T OFF   turning the write possibility off  Set  gt  2s ON   turning the write possibility on      Fig  12b Algorithm of the watt hour meter work   menu of the optical interface     Menu of the  real time clock             Set  gt  2s  3 1        hee Scroll esM S   Change of date and hour  Ii n    52 cuna 2 Scroll of the real time clock  Set  4 j m    Range of changes                D Scroll  Set C  gt                   2001   2035  dd    355 scroll   d month  01   12  Set    dd   day of the month  01   31  effet ie 2 Scroll   th   hour  00   23  Set     a tn   minute  00   59          ri    Set    5  Ak c 58 p Scroll    Set  Fig  12c Algorithm of the watt hour meter work   menu of the real time clock    2 Scroll Atc   automatic  change of time on oFF                               Menu of the accouting  period closure                                           Set  gt  2s  Manual closure of the  accounting period  Scroll Gai 5 Range of changes       cc nec 2 Scroll No  lack of operation  YES   period closing  Set Gmn  da el     Scroll Change of date and  time of the automatic  Set    3 accounting period closure                    me ome P Scroll Range of changes   Set S dd   closing day  01   28          th   closing hour  00   23  En Au 2 Scroll tn   closing minute  00   59  Set       Fig  12d Algorithm of the watt hour meter work   menu of the accounting period closure    14 
35. tions  the number of available  registers for readout can be smaller     Table 11    Identifier   ASCII  charac   ters     Format of  ASCII charac   ters  example   of contents     12 34 56    Parameter    Current time       25 11 02    Current date  dd mm yy        AbcDeFgHiJ    User s identifier       02110001    Factory number       000123 4 kWh    Energy in zone 1       000423 4 kWh    Energy in zone 2       000623 4 kWh    Energy in zone 3       000723 4 kWh    Energy in zone 4       001323 4 kWh    Total energy from all zones       10 23 20 11 02     99 2 kW    Time and date of the maximal 15   30  or 60  power occurrence  and its value        70     10 23 20 11 02    Time and date of the account period closure        0 8 1 00    000123 4 kWh    Energy in zone 1 at the end of the previous account period        0 8 2 00    000423 4 kWh    Energy in zone 2 at the end of the previous account period        0 8 3 00    000623 4 kWh    Energy in zone 3 at the end of the previous account period        0 8 4 00    000723 4 kWh    Energy in zone 4 at the end of the previous account period       0 8 0 00    001323 4 kWh    Total energy at the end of the previous account period        0 6 0 00    10 23 19 11 02     90 2 kW    Time and date of the max  15   30  or 60  power occurrence in  the previous account period and its value        0 6    6344 7 kW    Cumulated power  max   65535         0 1        22352       Counter of account period closures  max   65535         23    Ident
36. ts   energy in zone T2 in the previous  accounting period       Detection of an erroneous contents   energy in zone T3 in the previous  accounting period       Detection of an erroneous contents   energy in zone T4 in the previous  accounting period       Detection of an erroneous contents   total energy in the previous accounting period       Not used       Incorrect value of the error register          14  INTERNAL CONTROL CLOCK  OPTION     The LS1 1  watt hour meter has an astronomical time clock supported by a battery  The current  time is counted in the 24 hour  format    This clock is used for the time zone switching  The clock has the function of the automatic change  from the winter time into the summer time and inversely  The transition from the winter time into  the summer time is carried out in the night from Saturday to Sunday  on the last Sunday of Mars  the clock is being transposed from 2 00 to 3 00 o clock  The transition from the summer time into  the winter time is carried out in the night from Saturday to Sunday  on the last Sunday of October  the clock is being transposed from 3 00 to 2 00 o clock  If the user set the current time between  2 00 and 3 00  on the last Sunday of October  the clock assumes the summer time     15  TECHNICAL DATA  Kind of network 2   wire    Connection way of the watt hour    meter direct   Reference voltage U  acc  to the version code  Basic current     acc  to the version code  Maximal current I    acc  to the version code  Ac
37. user  energy receiver     The watt hour meter equipment with a communication interface or a radio transmitter gives the  possibility of a permanent monitoring  data archiving  visualization and report     The LS1 1 watt hour meter can be included into existing computer networks  what is rendered  possible by offered interface and protocol converters produced by LUMEL     3  WATT HOUR METER SET    The set of the watt hour meter is composed of       LS1 1 watt hour meter 1 pc    User s manual 1 pc    Warranty card 1 pc    4  WATT HOUR METER DESIGN    The construction of the LS1 1 watt hour meter is presented on the fig  1    The watt hour meter housing is made of an insulated material  lexan  and ensures the service  safety in the protection class II    The review and setting of watt hour meter parameters are realized by the button  4  situated  in the shield  8   The button is adapted to be sealed with lead  After sealing the button  there is  possible to review selected data on the display    The function of parameter setting is accessible after removing the leaden seal and turning the  button     2  LCD display        a 3  Upper hanger              4  Button  TYP LS1 1 RR     RsS485 Modbus  seo vom  i 5 60 A 230V 50Hz 9  LED diode  1  Base                    4 PLT 05 307  8  Shield  terminal box                        7  Shield    Fig  1a Watt hour meter design   view of the watt hour meter with the fixed terminal box  shield  7     1  Base     7 digit liquid crystal display
38. wer   The measurement of maximal power can be performed in 15  30 or 60 minutes  periods  The  locking mode or the shift mode is accessible to calculate the power    For the shift mode  one can choose 5 or 3 subperiods falling on the integration period    For 15 minutes  there will be 3 or 5 minutes  segments  for 30 minutes  6 or 10 minutes  segments  and for 60 minutes  12 or 20 minutes  segments  The selected number of subperiods composes  the period of power integration    After the first complete shift period including all subperiods  the next subperiod will be accounted  and the first is not be taken in consideration    The watt hour meter stores in its memory the maximal power for the current and the previous  accounting period  and the time and date of its occurrence     9 2 Cumulated power    The cumulated power is the power register increased by the averaged value of the maximal  power at the end of the accounting period     10 END OF THE ACCOUNTING PERIOD    At the moment of the accounting period closure  values of energy from all time zones and the  total energy will be memorized and at the same time  values of the accounted energy do not  undergo to changes   The automatic closure can follow automatically  on the defined day of the month and in the given  time  The configuration consists on writing the minute  hour and day of the accounting period  closure  The closure of the accounting period  the date and time of this operation is written   When there is a lack
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Ergotron StyleView Sit-Stand Combo System with Worksurface  HP ProBook 4530s  安全データシート  Samsung ML-3471ND Uporabniški priročnik  Détecteur de bris de vitre sans fil Détecteur de bris de vitre  Pistola Mist-less manuale L400  Bedienungsanleitung Digitales Thermo  CyberPower RMCARD202  Chapter 10 - AutomationDirect  Haier L37K60B User's Manual    Copyright © All rights reserved. 