1. C MMUNICATI NS 25 P All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 4 Plug In Pin Out PIN STANDARD POWER PULL PIN NAME DESCRIPTION 1 0 SIGNAL ON STATE TYPE NOTE 1 SUPPLY Positive Supply Input Power N A N A 2 SUPPLY Positive Supply Input Power N A N A 3 ENABLE SUPPLY Enable Disable Supply Input N A PULL UP to Vin 681k 1 4 RXD UART Transmit Line Output N A N A 6 5 DSR UART Data Set Ready Output N A N A 6 6 CTS UART Clear to Send Output N A N A 6 7 RING UART Ring Indicator Output N A N A 6 8 DCD UART Data Carrier Detect Output N A N A 6 9 TXD UART Receive Line Input N A N A 6 10 DTR UART Data Terminal Ready Input N A N A 6 11 RTS UART Request to Send Input N A N A 4 12 GROUND Supply Reference Power N A N A 13 TRACE TX Debug UART Transmit Line Output N A N A 6 14 TRACE _RX Debug UART Receive Line Input N A N A 6 15 USER LED USER LED Output N A N A 6 16 CELLULAR LED Cellular Status Output N A N A 6 17 SERVICE Unused N A N A N A 5 18 PWRMON Power Monitor Output Output N A PULL DOWN 1M 6 19 ON OFF Toggle Cellular Radio On Off State Input N A PULL UP to VTRC 47k 1 20 RESET Reset Cellular Radio Input N A PULL UP 47k 1 21 DVIWAO DVI Word Alignment WCLK N A N A 6 22 DVIRX DVI Received Data SDI
2. E2 0 4W 26 dBm EDGE 1800 1900 e GSM GSM RX Diversity and GPS available via Murata e Sensitivity GSC miniature RF connector e 109 5 dBm 850 1900 MHz e 109 dBm 900 Mhz e 110 dBm 1800 Mhz e 111 dBm WCDMA B1 B4 B5 e 110 dBm WCDMA B2 B8 3 4 Block Diagram HSPA910CF N 5 VDC ENABLE 1 8v PWRMON p me 2 85v VAUX sat SAAT Ne E 2 85v UART AT a CREER 3 2 85v UART TRACE p 1 8v PWRMON 2 85v PWRMON gt 18vGPlO BR Le 255 GPIO 3 7 p GPIO2 GPS USER LED p GPIO1 Cellular LED p USB lt ONOFF 1 8v DVI gt RESET 1 8v GPIO9 12C SDA p 1 8v GPIO10 12C SCL p 1 8v GPIO 1 8v UART AT E 1 8v UART TRACE 5 1 8v PWRMON ia y Optional SIM I C Figure 1 HSPA910CF Block Diagram JAN US HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page5 Rev P01 Date 08 28 14 REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS 25 P cae All Rights Reserved See website for latest revision Not intended for life support applications 4 INTERFACES 4 1 Serial Interface 4 1 1 UART Serial Port The serial interface is a CMOS level UART Default Communications settings for this port are as follows e Baud Rate 115 2 kbps e Bits 8 e Stop Bits 1 e Parity None e Hardware Handshaking Yes The HSPA910CF does not support autobaud and must be changed via the AT IPR command It is defaulted to 115200 bps Note If you are not using Hardwa
3. Janus Remote Communications Specifications subject to change without notice All Rights Reserved See website for latest revision Not intended for life support applications 5 HSPA910CF TECHNICAL SPECIFICATIONS continued 5 2 Mechanical Specification 2 500 1 481 979 113 DIA 275 DIA KEEP OUT AREA BOTTOM SIDE 250 DIA KEEP OUT AREA TOP SIDE 325 MAX 100 oa i HSPA910CF 100 Figure 11 HSPA910CF Mechanical Dimensions JANUS HSPA910CF Plug In Hardware User Guide JA03 UM HSPA Page 19 Rev P01 Date 08 28 14 REMOTE C MMUNICATI NS Copyright 2014 Janus Remote Communications Specifications subject to change without notice All Rights Reserved See website for latest revision Not intended for life support applications 5 HSPA910CF TECHNICAL SPECIFICATIONS continued 5 3 Setting Up a Terminal Emulator for Use With the HSPA910CF Terminus 5 3 1 Set Up To interface with the module connect the serial interface to a PC and use a terminal emulation program such as Microsoft Hyperterminal Set the interface parameters as follows e Baud Rate 115 2 kbps Bits 8 Stop Bits 1 e Parity None e Hardware Handshaking Yes 5 3 1 1 Test the Emulator Set Up e Enter AT lt cr gt from terminal and wait for OK Note that Autobaud is not supported on the HSPA910CF Terminus If you are utilizing the serial interface and you wish to change the baud rate
4. allows you to send a text message max 160 characters to a SMS capable subscriber unit e Set the SMS mode to text This must be entered every power cycle AT CMGF 1 lt cr gt e To enter the receiving subscriber unit phone number and message enter AT CMGS 8885551 234 Wait for response gt then enter message text Enter ctrl z lt cr gt to end the message 5 3 6 Making a GPRS Data Call 5 3 6 1 Set Up GPRS is a data service that uses Packet Data Protocol PDP e Set up the PDP context parameters Enter AT CGDCONT 1 IP APN 0 0 0 0 0 0 lt cr gt Where APN is specific to the service provider being used e Activate the PDP context Enter ATHSGACT 1 1 v p Where v is your user ID and p is your password If these are not set replace with e Open the socket connection Enter AT SD 1 0 IPPIPA 0 0 0 Look for response CONNECT This opens a remote connection via socket IPP the remote host port of the server you are trying to connect to 0 to 65535 IPA the IP address of the server hyou are trying to connect to in the format XXX XXX XXX XXX e Atthis point a data session is active and data can be sent from the Terminus to the remote device and visa versa e To exit the data session and return to command mode send the characters and wait for the OK response e Enter AT SH 1 to close the socket HSPA910CF Plug In Hardware User Guide JA03 UM HSPA Page 22 Rev P01 Date
5. digital output of another device and report its status provided this device has interface levels compatible with the Voltage levels of the GPIO of the module 4 6 2 Using a GPIO Pad as OUTPUT The GPIO pads when used as outputs can drive CMOS digital devices or compatible hardware When set as outputs the pads have a push pull output 4 6 3 Analog to Digital Converter ADC Description 1 Analog to digital converter input 4 6 4 12C The I2C interface is an alternate function of the modem s GPIO for the HSPA910CF those two signals are designated for GPIO 9 SDA and GPIO 10 SCL and are 1 8V logic level to match the DVI interface for easy usage with a codec The signals are not pulled up on the Plug In module and must be pulled up externally as they may also be used as spare GPIO Please reference the Telit AT Command Guide for details on the 12C commands 4 6 5 ENABLE Pin Input Logic State Description High Z Active state 0 Shutdown Notes 1 It is required that this input be controlled by an open collector drain output Do not use an external pull up resistor a pull up to VIN is included internal to the Terminus 2 The ENABLE pin is offered as a means to turn off the on board regulator for when a full power cycle is needed or an ultra low power state is required The ENABLE pin is not intended to be used as a means of turning the Terminus off use the ON OFF pin to turn the Terminus on or off 3 Shut down st
6. 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 5 3 HSPA910CF GETTING STARTED continued 5 3 Setting Up a Terminal Emulator for Use With the HSPA910CF Terminus continued 5 3 7 GPS The GPS data can be acquired over the AT Command port with the following methods Method 1 Send command AT GPSP 1 lt cr gt Send command AT GPSACP lt cr gt GPSACP can retrieve GPS data at any point when GPSP 1 Method 2 Configure Unsolicited NMEA Data Send command to enable NMEA stream AT GPSNMUN lt enable gt lt gga gt lt gll gt lt gsa gt lt gsv gt lt rmc gt lt vig gt lt cr gt Select parameter 1 to enable or 0 to disable for your NMEA stream requirements EXAMPLE AT GPSNMUN 1 1 1 1 1 1 1 Send command AT GPSP 1 lt cr gt End NMEA Stream Send command AT GPSP 0 lt cr gt 5 3 8 Further Instructions On utilizing different commands for other applications than those described here please refer to these reference documents listed in section 2 1 e Telit HE910 AT Commands Reference Guide e Telit HE910 Software User Guide JAN US HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 23 Rev P01 Date 08 28 14 REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See webs
7. AL SPECIFICATIONS continued 5 1 Electrical Specification continued 5 1 7 USB Transceiver Specifications Parameter Comments Min Typ Max Unit USB_VBUS Supply voltage 4 5 5 0 5 25 Volt Supply current 25 mA Input levels for low full speed Receiver threshold single end 0 8 2 0 Volt Differential input sensitivity D D Vin 0 8V to 2 5V 0 2 Volt Differential common mode range Includes VDI 0 8 2 5 Volt Output levels for low full speed Low RL 1 5 KQ to 3 6 V 0 3 Volt High RL 15 kQ to GND 2 8 3 6 Volt Output signal crossover voltage 1 3 2 0 Volt Terminations Internal pull up resistor VTRM to D VTRM to D 1 425 1 5 1 575 kQ Internal pull down resistor D to GND D to GND 14 3 15 24 8 kQ High Z state output impedance 0 V lt VDD lt 3 6 V measured at D and D pins to GND 300 7 kQ Termination voltage An internal supply voltage VTRM 3 0 3 3 3 6 Volt Driver characteristics full speed Transition time Rise time CL 50 to 125 pF 4 E 20 ns Fall time CL 50 to 125 pF 4 20 ns Rise fall time matching 90 111 Series output resistance D D 28 33 44 Q Driver characteristics low speed Transition time Rise time CL 50 to 600 pF 75 300 ns Fall time CL 50 to 600 F 75 7 30 ns Rise fall time matching 80 125 HSPA910CF Plug In Hardware User Guide JA03 UM HSPA Page18 Rev P01 Date 08 28 14 JANUS cvor C MMUNICATI NS Copyright 2014
8. HSPA910CF GETTING STARTED continued 5 3 Setting Up a Terminal Emulator for Use With the HSPA910CF Terminus continued 5 3 3 Setting Up Service Network Settings 5 3 3 1 Set Up The network settings for the Terminus will vary depending on the cellular carrier you are using Below are two of the North American Cases for these settings For T mobile amp MNVO Raco Sensor Logic Nexaira Jasper Wireless enter e AT SELINT 2 use of most recent AT command set AT STIA 2 10 or ATHSTIA 1 enable SAT SIM Application Tool Kit AT BND 38 3 default bands to 850 1900 2100 AT AUTOBND 1 enable Quad band system selection AT amp PO save profile AT amp WO save setting e AT ENS 0 For AT amp T Cingular amp MNVO Kore Aeris nPhase enter e AT SELINT 2 use of most recent AT command set e AT ENS 1 AT amp T Cingular configuration SAT BND AUTONBND PLMNMODE plus Cingular specific ENS requirements If Terminus is being used in a different country or with a different carrier please refer to Telit AT command refer ence document regarding the use of the AT BND command to set the proper frequency band Important After entering either of the sets of settings above power the Terminus OFF and then ON It is now ready for use 5 3 3 2 Check Network Status assuming you have a valid SIM card installed Enter AT CREG lt cr gt And wait for response Response will be CREG 0 1 or CREG 0 5 meaning the device is registere
9. HSPA910CF Terminus Plug In Products User Manual JANUS REMOTE C MMUNICATI NS au Date 28 Aug 2014 TABLE OF CONTENTS TABLE OF CONTENTS and DISCLAIMER i rurisusera sen stuciscecnasnswicn iden saben ccadtasadvacnd edesmncnuread tines nd ns atuns demie cette dene in cents 2 I APPLICABILITN TABLES Sn ccs A e EAE sagan EAE ss suutedat tcavaudestysdestidest sss chapteviatunvensastarvietager des 3 2 REFERENCES s 22 teen aa A sets aesnn rE ennemies lala hiner emi natures 3 2 1 Telit Document List sense e hrs ane tadi aeiia ea Eaa Naaa E space entendre asser tn arr nude ndnagt tonnes 3 CRO EE UE NE D ses atnanaesdaas E E ES 4 Sit troduction PE EI eee 4 SIZ AE E A E E A E sans sn Anar een nm as furet eape E san nnme ne aptes danse nest cs teec state legs 4 3 3 HSPA PGAQUICS arre nipoen saaana aa aaen a a aTa a Oaa aa aA r RA a iagaaseadscheaacdsceayendeavsacteauecenasiaage 5 3 4 HSPA Block Diagramme iienaa aaaea aaas aaa aha adaon a RA aeia aE aa aaan ERER 5 LINTE RFA Seta a tea dca ta ane nn teen datas detec ade a E E R 6 14 4A Seialntena enean T A eed ee en ae 6 7 4 2 POWEl Supply idiss eniai iaai aoaia daar dede irana iio aa E aSa tre etai Eiaa 8 4 3 Audio ICINE eL EEE ET T E EATA 9 AeA Plug In PIN Ut eia s e e a e a ia eed i ee Re A OC ee es 10 AO VRIG Details st ARR et ah r ante a eee rl aa ae Mania ak abate 11 4 6 GPIO Details cierran aranne aeaee e arsaa apaa nage tb ad der dn fa gu tee Ka bradain aea saa aaa a ia
10. Manual for the Plug In Terminus devices is intended to illustrate how users can integrate and implement the features of each communication version of the device The common factors are explained in detail as well as special considerations and diagrams for each module The module differences are highlighted in this manual for design considerations for future model placement 3 2 Preview The Terminus Plug In Modems are self contained multi band globally capable M2M communication devices designed to provide a comprehensive solution to application problems for our M2M customers They utilize the proven technology of Telit s certified modules respectively for their core communications engines NavSync s MS20 module adds the flexibility of GPS to the GSM865CF only 3 2 1 Functional Description GPS Functionality e An internal GPS solution is available via Telit AT command interface Cellular e HSPA UMTS EDGE GPRS GSM USB e HS FS USB 2 0 Device 480Mb s Physical Dimensions e Length and width of all Plug In devices are equal e Heights of different devices will vary 2 300 100TYP 047 DIA 49 050 i 7 9 Soest OS ee ees ess eee 6 ess PINA49 PIN26 1100 TOP VIEW PIN1 PIN25 Jesccososssossssitescesst 100TYP ji 2 400 z HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 4 Rev PO1 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Co
11. N N A N A 6 23 DVITX DVI Transmitted Data SDOUT N A N A 6 24 DVICLK NDVI Data Clock BCLK N A N A 6 25 GROUND Supply Reference Power N A N A 26 GROUND Supply Reference Power N A N A 27 USB _D USB Differential Data CMOS Bi Direction N A N A 28 USB_D USB Differential Data CMOS Bi Direction N A N A 29 USB_VBUS USB Supply Power N A N A 30 USB_ID Future Use Analog Input N A N A 2 3 31 I2C SDA 12C Data CMOS Bi Direction INPUT N A 32 I2C SCL 12C Clock CMOS Bi Direction INPUT N A 33 GPS_RX Unused N A N A N A 5 34 GPS TX Unused N A N A N A 5 35 GPS_RESET Unused N A N A N A 5 36 GPIO_7 General Purpose 1 0 Bi Direction INPUT N A 6 37 GPIO 6 General Purpose I O Bi Direction INPUT N A 6 38 GPIO_ 5 General Purpose 1 0 Bi Direction INPUT N A 6 39 GROUND Supply Reference Power N A N A 40 GPIO 4 General Purpose 1 0 Bi Direction INPUT N A 6 41 GPIO_3 General Purpose I O Bi Direction INPUT N A 6 42 GPIO 2 Unused N A N A N A 5 43 GPIO_1 Unused N A N A N A 5 44 DAC Unused N A N A N A 5 45 ADC2 Unused N A N A N A 5 46 ADC1 Analog to Digital Converter Analog Input N A N A 6 47 _VRTC Cellular Radio External RTC Supply Power N A N A 48 VAUX Reference Voltage Analog Output N A N A 49 GROUND Supply Reference Power N A N A Notes 1 It is required that this input be controlled by an Open Collector Drain Output Do not use an external pull up resistor a pull up is included internal to the module 2 Not currently implemented 3 USB On The Go Analog inp
12. O Details continued 4 6 10 PWRMON Pin Output Logic State Description 0 Terminus powered down 1 Terminus powered on Notes 1 Used in conjunction with ON OFF pin to control power on and power down state 2 During a power down it is required to stop driving terminal inputs high by floating or bringing them low If this is not done the PWRMON output will not transition low On the GSM865CF and HSPA910CF this will cause the VAUX output to remain active 4 6 11 VAUX A regulator power supply output that is provided in order to supply small devices from the module itself When PWRMON is HIGH VAUX will be ON When PWRMON is LOW VAUX will be OFF 4 7 User LED The HSPA910CF comes equipped with GPS functionality that is built into the cellular radios However the cellular radios have no GPS status output for driving an LED Instead this module has GPIO2 connected to the User LED pin of the Terminus The user application can use this to control an LED or act as an additional GPIO See figure 10 for recommended connection of an LED 4 8 LED Status Indicators The LED Status output is used to drive an external LED to give feedback on the current operation See figure 10 for recommended connection of an LED For the HSPA910CF this is an alternate function of GPIO1 and must be set via the AT GPIO command The status is defined below 4 8 1 Cellular LED Status HSPA910CF LED Status Device Status Permanently Off Cell
13. aa aiie a 12 13 4 7 Internal NtemtaCeS ec sisii iraa aaa eaaa aa aaan aeaaaee agn 13 4 8 LED StAtUs INACIO S 22 nn a N den ann RAE AR te aE E ES DIETA 13 49 SAPIMGMACS ss roana aTe Ea a E aad irene tee stan 14 AAO SIM Card Interface naea iienaa aaka sa Eaa asa aAa adaa a REEE ea ire A aE KAE AEE ENEAN 14 4 11 Header Interface Mounting Options iisiicccccccccccccaseccstesstseasscetescstceaniicaaescceasescesevaedesiacecencedseasageaeutedeasabentesbedeauateataaee 14 4 12 Screw Mounting icine ee et Sa ed ee 14 D ASPASIOCE TECHNICAL SPECIFICATIONS 2 cas ceset ee itendns scene nesqare ei aned eere E E eres aie Aleta ete 15 23 5 1 Electrical Specifications i issiscscdseseasuievexssercechedacgaaceseadeedisacecvessbenasddeceazataudechesdaztcenavtstsnduddedachecsagacecysace converging ane 15 18 5 2 HSPA Mechanical Specifications ii inccccsicccaceccecsatscxesuisecisnneessnceccsseedadaetncanstceasivensuceacntaduestcuecaduretsnauedsaracensvaetdensed 19 5 3 Setting Up a Terminal Emulator for use with the HSPA910CF Terminus c ceeceeeeeeeeeeeeteeeeeeteeeeteaeeeneeeeaee 20 23 6 DESIGN CONSIDERATIONS siaestewsees cece citecciges ce ra anasan ANSE EEN O EEEN E EON hag OEE NEA AEAN E EEEE ENESTE 24 6 1 GSM CDMA UMTS HSPA and EV DO Minimum Required Module Pin Connects sesseesseeeesreereerresreerrens 24 6 2 DODUG EPE E E E A E E E E T 24 APPENDICE Skit nran are E AN E E a Racca ev N N NNR 25 APProval Sanna a a a a a eae 25 SE LEON ARPEI AT 25 Anten
14. ate 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications APPENDICES Approvals AT amp T Certification PTCRB Certification FCC Certified CE Certified Safety Recommendations for Information only Antenna Care and Replacement Do not use the Terminus with a damaged antenna Buy the antenna from an approved suppliers list Using unauthorized antennas modifications or attachments could damage the Terminus and may violate local RF emission regulations or invalidate type approval Abbreviations 3GPP 3rd Generation Partnership Project AC Alternating Current ITAR International Traffic In Arm Regulation ADC Analog To Digital Converter LED Light Emitting Diode BER Bit Error Rate M2M Machine To Machine CD Carrier Detect PBCCH Packet Broadcast Control Channel CDMA Code Division Multiple Access PDU Protocol Data Unit CSD Circuit Switched Data RF Radio Frequency CTS Clear To Send RI Ring Indicator DB Decibel RSSI Received Signal Strength Indication DBFS Decibels Full Scale RTS Request To Send DC Direct Current RxD Received Data DCE Data Communications Equipment SMS Short Message Service DSR Data Set Ready TTFF Time To First Fix DTMF Dual tone multi frequency TxD Transmitted Data DTR DTE Ready UICC Universal Integrated Circuit Card FDN Fixed Dialing Num
15. ate must be held for 10ms before returning to active state 4 The regulator is operational 2mS after active state is entered s gt ENABLE R3 10k 5 2 mt de CMOS DRIVER gt NPN www infineon com BC FU Figure 6 Enable Pin JAN US HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 11 Rev PO1 Date 08 28 14 REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS 25 P cae All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 6 GPIO Details continued 4 6 8 RESET Pin Input Logic State Description High Z Active state 0 Reset state Notes 1 It is required that this input be controlled by an open collector drain output Do not use an external pull up resistor a pull up is included internal to the Terminus 2 The RESET pin is offered as a means to reset the Terminus when and if the Terminus becomes unresponsive The RESET pin is not intended to be used as a means of turning the Terminus off Use the ON OFF pin to turn the Terminus on or off 3 RESET state must be held for at least 200ms before returning to active state gt RESET 2 ee NPA www infineon com BCE Bw Figure 7 Reset Pin Diagram 4 6 9 ON OFF Pin Input Logic State Description High Z Terminus turned ON or OFF after input returns to this state 0 Toggle Terminus ON or OFF Notes 1 It is r
16. ber UMTS Universal Mobile Telecommunications System GPIO General Purpose Input Output USIM Universal Subscriber Identity Module GPRS General Packet Radio Service USSD Unstructured Supplementary Service Data GSM Global System Mobile VSWR Voltage Standing Wave Ratio WAAS Wide Area Augmentation System HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 25 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications Terminus Plug In Products User Manual Ordering Information Ordering Information Description HSPA910CF v1 00 Terminus HSPA Plug In Modem GPS Enabled Revision History Revision Revision Date Note POO 07 22 14 Preliminary HSPA910CF Individual Plug In User Manual po 08 28 14 Updates and Edits to Interfaces Pin Out JANUS sucre NS Janus Remote Communications Europe Division of The Connor Winfield Corporation Bay 143 2111 Comprehensive Drive Aurora Illinois 60505 Shannon Industrial Estate 630 499 2121 Fax 630 851 5040 Shannon Co Clare Ireland j Phone 353 61 47 www janus rc com one 353 61 475 666
17. d to the home network or roaming respectively If response is different than this please refer to the Telit AT command reference document for more information 5 3 3 3 Check Signal Quality Enter AT CSQ lt cr gt And wait for response CSQ lt rssi gt lt ber gt lt rssi gt Signal Strength 99 Not known or not detectable 0 31 dBm rssi 2 113 Example A result of 31 indicates 51dBm or greater An rssi value of gt 10 in typical applications is fine and you will usually see about 12 20 in normal to good signal but note that worst case it can be lower still register and perform normal functions 5 3 4 Making a Voice Call 5 3 4 1 Set Up Voice call mode allows you to use a telephone handset to communicate with a properly equipped subscriber unit e Set the call mode to voice Enter AT FCLASS 8 lt cr gt and wait for response OK e Dial the phone number Enter ATD lt 8885551234 gt lt cr gt e To disconnect the call enter ATH lt cr gt HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 21 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 5 3 HSPA910CF GETTING STARTED continued 5 3 Setting Up a Terminal Emulator for Use With the HSPA910CF Terminus continued 5 3 5 Sending an SMS 5 3 5 1 Set Up SMS Select Message Service mode
18. equired that this input be controlled by an open collector drain output Do not use an external pull up resistor a pull up is included internal to the Terminus 2 The ON OFF pin is offered as a means to power on and power down the Terminus When the Terminus powers down it informs the cell tower that it is powering down and will not be communicating with the tower any more This is considered a controlled power down After toggling the power state of the Terminus wait until PWRMON indicates chosen state before toggling the power state again To turn ON the plug in module the ON_OFF input must be tied low for 3 second then released To turn OFF the plug in module the ON_OFF input must be tied low for 2 seconds then released Optionally the Terminus may be powered down with the use of AT commanas It is required to stop driving terminal inputs high when turning ON the Plug In module by floating or bringing them low If this is not done power sequencing issues May occur NO 9 w ON OFF Ri 10k 5 CMOS DRIVER SAn A el NPN uw infineon com BCE Bw Figure 8 On Off Pin Diagram HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 12 Rev PO1 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS 23 P cae All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 6 GPI
19. ights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 2 Power Supply The module s power supply accepts input voltages from 4 75Vdc to 5 25Vdc and requires a nominal current sourcing capacity of 5W maximum 10W Power Supply A good understanding of the load transients is required in order to meet the power requirements of a cellular radio Power supply design thermal management and layout are outside the scope of this document Please refer to power supply manufacturers for product documentation and design application notes Cellular Load Transients Cellular radios use a mix of modulation schemes including but not limited to TDMA and CDMA In GSM GPRS systems the transmission and reception of data is achieved via Time Division Multiple Access TDMA TDMA transmission is made up of RF bursts that cause 2A current pulses at the supply input of the cellular radio These current pulses occur at a frequency of 216 Hz and can persist for 1 2 to 2 4ms On Board Regulator This Terminus Plug In module is designed with a switching regulator to power the cellular radio The regulator can receive an input voltage of 3 7 to 5 25VDC to maintain regulation but can also accept down to 3 3VDC in which regulation is bypassed This is useful for battery operated applications Note that an input voltage below 4 75VDC is outside of rated specifications and thus not supported by Janus Note The reg
20. ite for latest revision Not intended for life support applications 6 DESIGN CONSIDERATIONS 6 1 Minimum Required Module Pin Connects HSPA Pin Functions Pin Signal Function Note 1 VBATT Main power supply 2 VBATT Main power supply 12 GND Ground 25 GND Ground 26 GND Ground 39 GND Ground 49 GND Ground 9 TXD Serial data input TXD from DTE 4 RXD Serial data output to DTE 11 RTS Input for request to send signal RTS from DTE 2 19 ON OFF Input command for switching power ON or OFF toggle command 20 RESET Reset input Note 1 If the application uses USB as the main interface to the module this is sufficient to capture any debug or trace data provided the application can export the diagnostic port externally 2 RTS must be connected to ground if flow control is not used 6 2 Debug Debug of the Plug In Modems in production To test and debug the mounting of the module we strongly recommend test pads on the host PCB This will allow verification of the connection between the module itself and the application and to test the performance of the module connecting it with an external computer Depending on the customer application these pads include but are not limited to the following signals e TXD e RXD e ON OFF e RESET e GND e VBATT e TX_TRACE e RX_TRACE e PWRMON e USB D e USB D e USB V_BUS e USB_ID HSPA910CF Plug In Hardware User Guide JA03 UM HSPA Page 24 Rev P01 D
21. mmunications Specifications subject to change without notice C MMUNICATI NS cae All Rights Reserved See website for latest revision Not intended for life support applications 3 OVERVIEW continued 3 3 Features e Penta Band HSPA e Coding scheme 1 to 4 GPRS amp Modulation Coding e GSM Quad Band 850 900 1800 1900 MHz scheme 1 to 9 EDGE e UMTS HSPA Penta Band 850 900 1700 e EDGE Class 33 MS Class B 1900 2100 MHz e Data e EGPRS WCDMA HSDPA HSUPA Protocol Stack 3GPP e HSPA DL Up to 21 0Mbps UL Up to 5 76Mbps Release 7 e WCDMA DL Up to 384kbps UL Up to 384kbps e Control via AT commands according to 3GPP TS27 005 27 007 and Telit customized AT commands EDGE DL Up to 296kbps UL Up to 236 8kbps GPRS DL Up to 107kbps UL Up to 85 6kbps e Serial port multiplexer 3GPP T27 010 Asynchronous non transparent CSD up to 9 6 kbps e SIM application Tool Kits 3GPP TS 51 014 e DARP e SIM access profile e Dimensions TBD e UDP TCP FTP SMITP Stack e Operational Temperature Range 40 C to 85 C e Voice and SMS e Internal Switching Regulator e Output power e Input Voltage Range 3 0 to 5 25Vdc 5Vdc nominal e Class 4 2W 33 dBm GSM 850 900 e Supply disable via terminal input pin e Class 1 1W 30 dBm GSM 1800 1900 e SIM Card e Class 3 0 25W 24 dBm UMTS e Standard locking SIM card socket e Class E2 0 5W 27 dBm EDGE 850 900 e Optional SIM chip e Class
22. n Typ Max Unit Note Input Voltage High Vih 1 5 1 9 Volt Input Voltage Low Vil 0 0 35 Volt Output Voltage High Voh 1 6 1 9 Volt Output Voltage Low Vol 0 0 2 Volt Typical Current Source Sink 100uA 1uA 5 1 4 2 2 85v Standard Interface Levels UART GPIO Parameter Min Typ Max Unit Note Input Voltage High Vih 1 85 2 85 Volt Input Voltage Low Vil 0 0 99 Volt Output Voltage High Voh 2 45 2 85 Volt Output Voltage Low Vol 0 0 4 Volt Typical Current Source 100uA 1uA 5 1 4 3 Cellular LED Output Levels Parameter Min Typ Max Unit Note Output Voltage High Voh 1 6 1 9 Volt Output Voltage Low Vol 0 0 2 Volt Typical Current Source 100uA 5 1 4 4 ADC Input Levels Parameter Min Typ Max Unit Note Input Voltage Range 0 1 2 Volt AD Conversion 10 Bits Input Resistance 1M a Ohm Input Capacitance 1 pF 5 1 4 5 Reset Pin Input Levels Parameter Min Typ Max Unit Note Input Voltage High Vih 1 5 1 9 Volt Input Voltage Low Vil 0 0 35 Volt It is required that this input be controlled by an Open Collector Drain Output Do not use an external pull up resistor a pull up is included internal to the Terminus HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 16 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Right
23. na Gare and Replacement ccc iiceccsseccecncencssttcuasa cassusntceduachcasteceasnednsnadteyacaeceavavedhathavscvcbcaithedieastiveadadeasvaevaented 25 ADDIE VIALIONS soiin naar enean aee Ea a e Ge aeaa tadcaeed deccuacaebtaseesuausveaataceave acer uarited ise 25 Ordering IMOrmatiO M reesi ane ee le esd ed aed see es 26 PROVISION ISOM iescceadaccte sae cuca duce sasvaccccdun cease ccnsyactcvest chnsvetedieshdaceaitsehtecdecsanueeachideduestduayadacdelnedtaverecusdigbecssnisusdniveeiecesd 26 DISCLAIMER The information contained in this document is the proprietary information of Connor Winfield Corporation and its affiliates Janus Remote Communication The contents are confidential and any disclosure to persons other than the officers employees agents or subcontractors of the owner or licensee of this document without the prior written consent of Connor Winfield is strictly prohibited Connor Winfield makes every effort to ensure the quality of the information it makes available Notwithstanding the foregoing Connor Winfield does not make any warranty as to the information contained herein and does not accept any liability for any injury loss or damage of any kind incurred by use of or reliance upon the information Connor Winfield disclaims any and all responsibility for the application of the devices characterized in this document and notes that the application of the device must comply with the safety standards of the applicable country and where ap
24. nterface in order to locally update radio firmware for CDMA and UMTS applications The GSM865CF does not have USB port available HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page6 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 1 2 USB Port continued 4 1 2 1 USB Connection Diagram RTI PTC 200MA www littelfuse com 0805L020YR o p usa wus lt lt 1_ A_A_ 2 usao lt FUTURE USE ui ESD ARRAY www semtech com RCLAMPOSO4F Ci 10uF 20 25V H Pi USB TYPE B SOCKET www samtec com USB B S F B TH 4 Ri 27 5 USB_D lt lt USB_D lt lt xx R2 27 5 6 Figure 3 USB Connection Diagram 4 1 2 2 USB VBUS Switch USB_VBUS is input when VBUS_ENABLE is HIGH the 5v signal will be passed to TERMINUS_VBUS turning the USB ON Ql P Channel MOSFET USB_VBUS le TERMINUS_VBUS R1 10K Ohm 5 R2 1 5K Ohm 5 Q2 _ N Channel MOSFET g VBUS_ENABLE R3 10K Ohm 5 R 680 G Figure 4 USB VBUS Switch Example HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 7 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All R
25. on the module you must use AT PR You must also change the rate in the host UART i e HyperTerminal to match the new baud rate If these do not match you will not be able to send AT commands to the module through the serial port The Terminus is by default set to 115 2 kbps 5 3 1 2 Verify Your Terminal and Firmware Version e Enter AT CGMM and wait for the response The response will be the Telit module s model number without a command echo e Enter AT CGMR and wait for the response The response will be the Telit module s current firmware without a command echo Please confirm your model and firmware with the one listed in section 2 1 5 3 2 Powering ON OFF 5 3 2 1 Turn the module ON through the following method e Pull ON OFF signal Pin 19 to ground for three 3 seconds then release The Terminus module is fully operational after 4 seconds Logging onto a network may take longer than this and is outside the control of the Terminus 5 3 2 2 There are two ways to switch OFF the module as described below e Use the appropriate AT command AT SHDN e Pull ON OFF signal Pin 19 to ground for three 3 seconds then release HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 20 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 5 3
26. plicable with the relevant wiring rules Connor Winfield reserves the right to make modifications additions and deletions to this document due to typographical errors inaccurate information or improvements to programs and or equipment at any time and without notice Such changes will nevertheless be incorporated into new editions of this application note All rights reserved 2014 Connor Winfield Corporation HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page2 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 1 APPLICABILITY TABLE Product Part Number HSPA910CF v1 0 2 REFERENCES 2 1 Telit Document List HSPA910CF Our terminal uses Telit module HE910 Please refer to Telit s website at www telit com for the latest information on the HSPA HE910 Module Telit HE910 Hardware_User_Guide Telit HE910 Software User Guide Telit HE910 AT Commands Reference Guide Telit_HE910_DVI_App_Note HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page3 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 3 OVERVIEW 3 1 Introduction The User
27. re Handshaking please note that RTS must be connected to GROUND for proper communications where flow control is unused 4 1 1 1 UART Level Translation The electrical limits for the UART are listed in the individual modem sections Please be aware of these limits as operating outside of them may damage the unit If the limits must be exceeded level translation can be used An example of basic translation for RXD TXD only is found below 2 8V TXD_5V patil TXD_2 8V GND RXD_SV RXD_2 8V TC7S2ZO7AFE GND Figure 2 UART Level Translation Example Although an external source for the level translation can be used VAUX can be used as the reference instead However because some Plug In Modems require AT commands to control VAUX PWRMON may be used as an enable to an external reference Do not use PWRMON directly as the reference 4 1 2 USB Port The Plug In modems that are USB ready include an integrated universal serial bus USB transceiver compliant with USB 2 0 specifications High data rates for the USB enabled modems are only available over the USB interface as the UART has a maximum baud rate of lt 1Mbps In order for proper power up of the Plug In Modems the USB_VBUS line MUST be disconnected until the unit is otherwise fully powered and on If the USB_VBUS line is attached and powered before the main power is brought up and the module turned on power sequencing issues may occur Note You must implement the USB i
28. receive incoming call sand SMS AT CFUN 7 WCDMA 10 0 CFUNE 5 full functionality with power saving Module registered on GSM 9 2 the network can receive incoming call sand SMS WCDMA HSDPA GPS OFF in HSPA910CF WCDMA Voice TBD voice channel WCDMA data 130 2 data channel GSM GSM Voice TBD GSM voice channel GPRS Class 12 129 3 GPRS data channel GPS ON AT CFUN 1 WCDMA 35 5 GSM 37 2 Idle no call in progress Full functionality of the module AT CFUN 4 WCDMA 36 8 Disabled TX and RX module is not registered on the network GSM 37 6 AT CFUN 5 WCDMA 28 9 Disabled TX and RX module is not registered on the network GSM 30 0 AT CFUN 7 WCDMA 33 8 Disabled TX and RX module is not registered on the network GSM 34 3 WCDMA HSDPA WCDMA Voice TBD WCDMA voice channel WCDMA Data 156 WCDMA data channel GSM GSM Voice TBD GSM voice channel GPRS EDGE Class 12 152 GPRS data channel except external active GPS antenna Data taken with USB disconnected HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 15 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS oa P ae All Rights Reserved See website for latest revision Not intended for life support applications 5 HSPA910CF TECHNICAL SPECIFICATIONS continued 5 1 Electrical Specification continued 5 1 4 I O Levels 5 1 4 1 1 8v Standard Interface Levels DVI 12C GPS LED Parameter Mi
29. s Reserved See website for latest revision Not intended for life support applications 5 HSPA910CF TECHNICAL SPECIFICATIONS continued 5 1 Electrical Specification continued 5 1 5 HSPA Cellular Antenna Specifications 5 1 5 1 Antenna Specifications Parameter Description Frequency Range Depending on frequency bands provided by the network operator the customer should use the most suitable antenna for those frequencies Bandwidth 70MHZ in GSM850 80 MHz in GSM900 170 MHz in DCS amp 140 MHz PCS 70 MHz in WCDMA850 80 MhHz in WCDMA900 460 MHz in WCDMA1700 140 MHz in WCDMA1900 250 MHz in WCDMA2100 Gain Gain lt 3dBi Impedance 50Q Input Power gt 33 dBm 2W peak power in GSM gt 24 dBm Average power in WCDMA VSWR Absolute Max lt 5 VSWR Recommended lt 2 1 5 1 6 HSPA910CF GPS Antenna Specifications 5 1 6 1 Antenna Specifications Parameter Description Input Voltage Range 2 85V Frequency Range 1575 42 2 MHz Gain lt 15dB overall at the connector Antenna and LNA included Impedance 50 ohm VSWR TBD Current Consumption 30mA Max 20mA Typ HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page17 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS a All Rights Reserved See website for latest revision Not intended for life support applications 5 HSPA910CF TECHNIC
30. tional SIM IC Consult factory representative 4 11 Header Interface Mounting Options The Plug In Modules header pin length has been chosen to allow for direct solder mount to a PCB of standard thickness If the user wishes to socket the Plug In Module they may do so as well by using the below part numbers for reference Samtec 25 pin header TSM 125 04 L SV A Samtec 24 pin header TSM 124 04 L SV A Mating Samtec 25 pin connector SLW 125 01 G S Mating Samtec 24 pin connector SLW 124 01 G S Please note there are no Samtec SMT single row mating connectors The only mating connector available is the above listed THT version 4 12 Screw Mounting The HSPA910CF allows for the use of a 4 machine screw to help keep a socketed module in place where environmental variables may cause problems otherwise If the user wishes to have a stand off underneath the module to help alleviate possible stress from mounting hardware below are the Janus part numbers and associated drawings for an available solution 4 40 Hex Female Stand off MC 0356 G 4 40 3 16 Pan Head Phillips Machine Screw MC 0357 G 080 3 16 iii te li QU AU LE Le s Figure 10 Screw Diagram i HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 14 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest re
31. ular radio is off Permanently On On Searching Slow Blinking 0 3 sec on 2 7 sec off Registered Fast Blinking 0 5 sec on 0 5 sec off Shutting down SUPPLY R3 ik 5 Di x LED www lumex com W SML LX04025YC 10 5 Lh CMOSORIMER gt NPN eee infineon com R2 47k 5 1 Figure 9 LED Indicators Diagram HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 13 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 9 RF Interface There are three RF interfaces on the HSPA910CF A cellular GPS and RX diversity connector The specifications and requirements for these are as follows Note You must access the RF connections via the SMT GSC connections if they do not include a GSC to SMA connector These signals are NOT electrically connected elsewhere on the board 4 9 1 HSPA910CF Antenna Interface Type Murata GSC MALE Murata Part MM9329 2700RA1 Pin Description Center Pin RF signal Outer Conductor Signal ground 4 9 2 Certified HSPA Antenna TBD 4 10 SIM Card Interface The SIM Card Interface allows the Terminus to accept the subscriber card provided by the cellular telephone provider It can accommodate a 1 8V or 3 0V SIM card and complies with the Phase 2 GSM 11 14 standard Op
32. ulator input is capable of withstanding 6VDC Maximum This is outside the recommended operating voltage of the Plug In modules but but is helpful to know when designing input transient circuitry Plug In Module Input Supply Requirements The current values are given in average units due to the pulsed nature of the transmission scheme It is recommended that your supply source the full peak current value of the transmission pulse in order to maintain proper cellular operation The use of bulk output capacitors on your supply allows for a less powerful supply 4 3 Audio Interface 4 3 1 HSPA910CF The 910CF modules use a DVI audio interface which will not work with the analog audio inerface of the other Terminus Plug In modems The HSPA910CF supports both 12S and PCM master and slave modes and can use a CODEC to convert the interface to analog Below is a block diagram based on DVI and the max 9867 CODEC with GPIO 9 and 10 being used for I2C control of the CODEC Please refer to the referenced DVI Application Notes for full information and example schematics utilizing the MAX9867 Audio CODEC SDA SCL BitClock Word Alignment lt gt Analog In Data Transmitted Analog Out Data Received D Figure 5 DVI Block Diagram HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 8 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice
33. um input voltage to function 1 1v IRTC 10uA nominal Values for the HSPA910CF VRTC 1 8v Nominal VRTC minimum input voltage to function 1 1v IRTC 2uA nominal Values for the EVDO910CF VRTC 3 1v Nominal VRTC minimum input voltage to function 2 0v IRTC 1 1uA nominal Values for the CDMA910CF VRTC N A VRTC minimum input voltage to function N A IRTC N A For Example using the HSPA910CF numbers Btime 96 hours 4 days C 1 0F 4 6 GPIO Details Terminus GPIO are configurable as input output and special function Configuration is controlled by the customer specific application via AT commands The following table describes GPIO configuration options GPIO Configuration Alternate Function ON_OFF State 1 Input Output Status LED pull up 2 Input Output User LED pull up 3 Input Output N A pull down 4 Input Output N A pull down 5 Input Output N A pull down 6 Input Output N A pull up 7 Input Output N A pull down HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page 10 Rev P01 Date 08 28 14 JAN U S REMOTE Copyright 2014 Janus Remote Communications Specifications subject to change without notice C MMUNICATI NS 2s P ae All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 6 GPIO Details continued 4 6 1 Using a GPIO Pad as INPUT The GPIO pads when used as inputs can be connected to a
34. ut used to sense whether a peripheral device is connected and determine the peripheral type a host or a peripheral 4 RTS must be connected to GROUND if flow control is not used 5 Not used on the HSPA910CF 6 Refer to the electrical specifications for I O levels JANUS ue C MMUNICATI NS HSPA910CF Plug In Hardware User Guide JAO3 UM HSPA Page9 Rev P01 Date 08 28 14 Copyright 2014 Janus Remote Communications Specifications subject to change without notice All Rights Reserved See website for latest revision Not intended for life support applications 4 Interfaces continued 4 5 VRTC Details The VRTC pin brings out the real time clock supply which is separate from the rest of the part This allows only the RTC to be ON when all other parts of the device are OFF A backup capacitor can be added to this pin to increase RTC autonomy while powering the device from a battery The CDMA910CF cannot take advantage of the VRTC functionality No devices should be powered from this pin Equations C 3600 Btime IRTC VRTC VRTCmin Btime C VRTC VRTCmin IRTC 3600 Where VRTC The Starting voltage of the capacitor Volt VRTCmin The minimum voltage acceptable for the RTC circuit Volt IRTC Ampere The current consumption of the RTC circuitry when VBATT 0 Btime Backup Time Hours C Capacitor value Farads Values for the GSM865CF CDMA864CF UMTS864CF VRTC 2 05v Nominal VRTC minim
35. vision Not intended for life support applications SSS e 5 HSPA910CF TECHNICAL SPECIFICATIONS 5 1 Electrical Specification 5 1 1 Absolute Maximum Ratings Parameter Min Typ Max Unit Note VIN DIGITAL INPUTS 2 85V CMOS 0 5 3 35 Volt VIN DIGITAL INPUTS 1 8V CMOS 0 3 3 1 Volt Storage Temperature 40 z 85 C Supply referenced to Supply 0 6 Volt Operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions is not implied Exposure to Absolute Maximum Rating conditions for extended periods of time may affect device reliability 5 1 2 Recommended Operating Conditions Parameter Min Typ Max Unit Note Temperature 40 85 C Supply referenced to Supply 4 75 5 0 5 25 Volt VAUX Output 2 85 Volt VAUX Current z 100 mA 5 1 3 Power Supply Mode Average mA Mode Description POWERED DOWN Terminal Disabled lt 15pA Terminal disabled ENABLE SUPPLY 0 Cellular Radio Off 0 4 Cellular module powered but switched off via ON_OFF pin PWRMON 0 IDLE MODE Mode Average mA Mode Description GPS OFF AT CFUN 1 WCDMA 13 8 Idle no call in progress Full functionality of the module GSM 13 9 AT CFUN 4 WCDMA 14 4 Disabled TX and RX module is not registered on the network GSM 14 4 AT CFUN 5 WCDMA 3 4 CFUN 5 full functionality with power saving Module registered on GSM 3 3 the network can