1. To remove the lithium power pack press on the unlocking key and slide the pack towards the right IMPORTANT e When the siren is powered it will issue a long beep and automatically switch to installation mode tamper mechanism disabled e If the siren does not respond as it should disconnect the power pack wait for 2 minutes reconnect the lithium power pack check the siren issues a long beep as it should 3 Recognition programming Recognition programming allows the siren to be recognised by the control panel It must be done with the control panel and siren in installation mode If they are not in installation mode enter Coor then CAGA master code installer code IMPORTANT e The siren does not need to be placed close to the control panel for recognition programming In fact it is advisable to move it away from the panel to a distance of at least 2 m e The control panel gives the siren a n during recognition programming Siren recognition programming sequence bip off control panel peeeep bip siren n DD gt lt 10 s max gt Briefly press Press and hold Off The siren issues The control panel the siren until the control panel an audible signal announces the siren n test button responds to confirm programming IMPORTANT the control panel and siren issue thre
2. 4 siren n 37 all groups Selection of group s from 1 to 8 depending on type of control panel 112 Parameter description Parameter setting Factory Possible values Page sequence parameter Type of warning 4 siren n 72 3 flashing 0 disabled 112 indication 1 sounding 2 sounding and flashing 3 flashing 4 vocal message G N 1 Barking n 1 flashing 5 vocal message N 2 Beware Intrusion alarm Armed n 2 flashing N 3 Beware Protected zone 6 vocal pet oa le n 3 flashing N 4 Intruder detected 7 vocal message N 5 Intrusion Alarm triggered n 4 flashing 8 vocal message n 5 flashing Type of deterrence 4 siren n 73 2 sounding 0 disabled 112 indication and 1 sounding flashing 2 sounding and flashing 3 flashing 4 vocal message 5 N 1 Barking n 1 flashing 5 vocal message N 2 Beware Intrusion alarm Armed n 2 flashing N 3 Beware Protected zone 6 vocal message Sale 7 n 3 flashing N 4 Intruder detected 7 vocal message N 5 Intrusion Alarm triggered n 4 flashing 8 vocal message n 5 flashing Type of prealarm siren n 74 2 sounding 0 disabled 112 indication and 1 sounding flashing 2 sounding and flashing 3 flashing
3. SH426AX External siren vocal messages flash INSTALLATION MANUAL DAITEM Contents 1 Introduction ee 103 2 Preparing the Siren ee 104 2 1 Tooling required pp 104 2 2 Opening the siren and connecting the power supply 104 3 Recognition programming 106 4 Setting the parameters 0000 107 4 1 Delayed alarm sounding UPON INtrUSION e eee ee eens 107 4 2 Setting the sounding parameters 107 4 3 Type of sounding pe 108 4 4 Sound level of arm and disarm command indications 108 4 5 Transfer of arm and disarm command indications 0 108 4 6 Indication of audible signals and door e E E 108 4 7 Validation of radio link in installation mode pp 108 4 8 Modification of speech synthesis system language 109 4 9 Triggering upon intrusion 109 4 10 Protection system armed indication e AST e EA 109 4 11 Alarm in armed presence mode indication pp 109 4 12 Triggering following a communication network interruption eea eaea eE 109 Recommendations 4 13 Radio tamper pp 110 4 14 Duration of flashing pp 110 4 15 Indication of break in following intrusion pp 110 4 16 Visual localisation of flashing strobe following break in 110 4 17 Allocation of siren to an alarm group pp 112 4 18 Type of indication pp 112 4 19 Anti tamper switch triggering 113 4 20 Fire alarm indication pp 113 4 21 Checking eese eee n a 113 4 22 D
4. Factory setting 0 2 enabled 24 h 4 16 Visual localisation of flashing strobe following break in The visual localisation function can be triggered following a break in indication if this function has been enabled or once the flashing duration has run its course By extending the effect of the flashing strobe on for 6 seconds off for 16 seconds the visual localisation function helps the user s correspondent to visually localise the premises where the alarm has been triggered See diagram on next page To modify the strobe s visual localisation function enter CJ BER Je JCS i6 iL iL 1 siren n 0 disabled 1 enabled 2 h Factory setting 0 2 enabled 48 h How the different functions work duration of flashing parameter 5 e break in indication parameter 35 e visual localisation of flashing strobe parameter 36 Duration of flashing 2 min Break in indication enabled or disabled 2min Visual localisation disabled Duration of flashing 5 min Break in indication enabled 3 min TT 2 min 1 visual localisation disabled gt gt Duration of flashing 3 min 5 min Break in indication enabled 24 h 3 3 min IHT EST Visual localisation disabled ar 24 h 3 min x Duration of flashing 2 min iar Break in indication enabled or disabled gt m BO I Visual localisation enabled 2 h gt lt 2h 2min ad Duration of flashing 5 min B
5. 4 vocal message E N 1 Barking n 1 flashing 5 vocal message N 2 Beware Intrusion alarm Armed n 2 flashing N 3 Beware Protected zone 6 vocal ren oa 7 n Tasning N 4 Intruder detected 7 vocal message N 5 Intrusion Alarm triggered n 4 flashing 8 vocal message n 5 flashing Anti tamper switch 4 siren n 75 enabled 0 enabled 24h day 113 triggering if system 1 enabled if totally system totally armed armed Fire alarm indication 4 siren n 76 sounding 0 sounding 113 and vocal 1 sounding and message vocal message Deletion of all 4 siren n 197 113 parameters Deletion of one 4 siren n parameter n 113 parameter ae Oe 9 Technical data Technical specifications SH424AX SH425AX SH426AX SH424AI sirens Acoustic level 109dBat im Sounding duration 20 s to 180 s Internal sounding 1400 Hz to 1600 Hz Fire sounding 700 900 Hz sounding duration 5 min Transfer of Arm Disarm indications sounding and vocal message Environment external Power supply TwinPower via lithium power pack 2 x 3 6 V Battery life 5 years in normal conditions of use Average current consumed 331 HA Average humidity rate 5 to 75 without condensation at 25 C possibly varying between 85 amp 95 for 30 days over the course of
6. JG siren n 0 normal 1 quiet Factory setting 0 4 3 Type of sounding To modify the type of siren sounding enter Be JL JY Le JL JEJBGJ OIBIC GP siren n 0 internal 1 external Factory setting external 4 4 Sound level of disarm and arm command indications For greater user friendliness the sound level can be increased or decreased To do this enter CJ GAR SPI DM BE 1 siren n from 1 to 8 Factory setting 4 average 4 5 Transfer of arm and disarm commands To modify the transfer of indications enter JP BE EJA JB IBOR JP siren n 0 disabled 1 sounding 2 vocal message bip bip bip bip Off or Armed 3 sounding and flashing 4 vocal message bip bip bip bip Off or Armed and flashing Factory setting 0 5 flashing 4 6 Indication of audible signals and door bell This function is factory set to be disabled It can be enabled if required To do this enter Be BE BYE RBG JBIBOL JP siren n 0 disabled 1 sounding Factory setting 0 4 7 Validation of radio link in installation mode This function is used to validate the radio link test in installation mode on 1 of the 2 radio bands To switch to 2 bands enter Lae IC JJ ICS Jee JC Ji JL siren n 0 validation on 1 of the 2 bands Factory setting 0 1 validation on 2 bands 108 4 8 Modification of speech synthesis system language The French language can be replaced by a
7. e of the control panel e of the telephone dialler 4 Issue an Off order Sh 7 1 Fault indications The control panel supervises and identifies the siren It monitors the state of the power supply e radio link e tamper contact If a fault is memorised the control panel issues a voice message to indicate the fault following a system command see Fault indications in the control panel installation manual The siren also provides vocal indication of faults following a command issued from a control unit Commands Vocal messages Disarm bip Off Alarm System or Fault System Disarm group bip Off or bip Off Group X Alarm System or Fault Voltage Siren or Fault System Arm with time delay bip Armed Exit Opened or Exit Inhibited or Faults System or Faults Voltage Siren Arm without time delay bip Armed Exit Opened or Fault System Armed Partial 1 or 2 bip Armed Partial 1 or 2 Exit Opened or Exit Inhibited or Faults System with time delay or Fault Voltage Siren Armed Partial 1 or 2 bip Armed Partial 1 or 2 Exit Opened or Fault System without time delay Arm Presence mode bip Armed Presence Exit Opened or Faults System or Fault Voltage Siren Arm Group with time delay bip Armed Group X Exit Opened or Exit Inhibited or Faults System or Fault Voltage Siren Arm Group bip Armed or bip Armed Group X
8. 02 x x x x EN 60950 2006 x x x x EN 301 489 1 V1 8 1 x x x x This product can be used in all EU EEA Countries and Switzerland Crolles 02 01 2013 Signature Patrick Bernard Research amp Development Manager Non binding document subject to modification without notice 121 SIOT 0 V LVLSO8 DAITEM wm
9. Exit Opened or Fault System without time delay System status bip Off Fault System bip Armed Presence Fault system bip Armed Exit Inhibited bip Armed Partial 1 or 2 Exit Opened or Fault System bip Armed Group Exit Opened or Fault System e Example 1 the siren s battery Bip System Status Armed aker 4 Bip Armed Partial 2 is indicated to be faulty Partial 2 bip 12 03 at 12 00 bip Fault System following a control panel Fault System System Status command e Example 2 exit 3 has not Bip Armed Partial 1 ER been closed and this is bip 12 03 at 12 00 eae Dat One indicated following a control Exit 3 Open panel Armed Partial 1 command 7 2 Changing the battery e The lithium battery pack must be replaced by the same type of pack with the same technical characteristics i e 2 x 3 6 V 13 Ah e We advise you to use the DAITEM BatLi22 pack available in the catalogue in order to guarantee individual safety and equipment reliability e Dispose of the waste lithium power pack in an appropriate recycling bin To change the battery 1 send a disarm command 2 switch the control panel to installation mode DOO then DOC master code installer code ENE EN 3 remove the siren from the wall 4 remove the faulty lithium power pack 5 wait for 2 minutes before connecting the new li
10. a space of 6 cm to the left of the be a space of 6 cm to the left of the base 4 cm above and 18 cm below base 4 cm above and 18 cm below This clearance allows for the siren to be This clearance allows for the siren to be easily opened or locked easily opened or locked e Fix the base at 3 points e Fix the base at 3 points the two fixing points A the two fixing points B the tamper mechanism AP the tamper mechanism AP Insert adjustable fixing washers here k A 4 cm i borti o AR 4 I B LO gt f 5 fo Eg Tamper mechanism Tamper mechanism hole with washer AP hole with washer AP Detachable tamper mechanism washer 2 Position the siren open at an angle of 45 A in y relation to the base and insert the pivots on the base into the hinges 3 Close the siren and lock it y using the screw located inside the product Bottom view of siren Siren opening Siren locking 6 Performing a real test Testing triggering when there is an attempt to remove the siren IMPORTANT the sounding level of the siren Loosen the siren locking screw can cause hearing disorders The necessary 2 Open the siren precautions must therefore be taken before 3 Check triggering testing siren triggering eof the sireh
11. ae J ee siren n 0 disabled 1 sounding loud for 15 s 2 sounding loud for 15 s Factory setting 2 and flashing 3 flashing 15 s vocal message n 1 flashing 15 s vocal message n 2 flashing 15 s vocal message n 3 flashing 15 s vocal message n 4 flashing 15 s vocal message n 5 flashing 15 s ONDAR 112 4 19 Anti tamper switch triggering To modify the conditions under which the anti tamper switch will activate the siren enter CJ CSL LJJa 73 La siren n 0 enabled 24 h day 1 enabled if system totally armed Factory setting 1 4 20 Fire alarm indication To modify the fire alarm indication enter JP ICM x EZ BB PE 1 siren n 0 sounding f Factory setting 1 1 sounding and vocal message Fire_Alarm 4 21 Checking To check parameter setting enter GJEJEGIGIOIRGICTIC IRER siren n parameter n Example to check on siren n 1 parameter 4 duration of sounding enter GG a RR 4 22 Deletion of parameters e To delete a parameter enter a BOP JJ GJE BEBE D 1 sirenn parameter n e To delete all parameters enter La Lae JC BUE GIBB ID BE DB Dr siren n 5 Installing the siren 5 1 Choosing the best place to install the siren IMPORTANT make sure there is a distance of at least 2 metres between each product except between two detectors The siren s
12. aitem co uk In addition to the protection provided by the control panel with built in siren and keypad the external siren with vocal messages and flashing strobe makes it possible to e deter intruders vocal messages e alert neighbours external sounding mode e easily locate the alarm flashing strobe If a fire is detected the siren is triggered for 5 minutes in fire sounding mode Thanks to its built in transmitter the siren informs the control panel when it has a battery problem If somebody attempts to pull the siren off the wall it sounds and then triggers all the alerts and deterrents via the control panel Vocal messages The siren issues the following vocal messages Following a command Vocal message Commands Disarm bip Off Arm bip Armed Armed Partial 1 or 2 bip Armed Partial 1 or bip Armed Partial 2 Disarm Group bip Off if all the groups allocated to the siren are disarmed bip Off Group X if only part of the groups allocated to the siren are disarmed Arm Group bip Armed if all the groups allocated to the siren are armed bip Armed Group X if only part of the groups allocated to the siren are armed Arm Presence mode bip Armed Presence Door bell ding dong Disarm under duress bip Off System Disarm bip Off status query arm bip Armed Armed Part
13. e short beeps to indicate a programming error When this happens perform recognition programming again from the start 4 Setting the parameters IMPORTANT all parameter setting must be done using TwinLoad software available in the Daitem installers section at www daitem co uk The control panel and siren must be in installation mode to set the siren s parameters If they are not enter L JL JL OC IA GE master code then bip installation bip installation OOOO Be es installer code The siren s parameters are factory programmed Each parameter can nevertheless be modified using the control panel keypad To set the siren s parameters first choose the parameters to be modified and then enter BEG siren n parameter parameter n value 4 1 Delayed alarm sounding upon intrusion Siren alarm sounding can be delayed by 60 seconds maximum This gives users enough time to disarm the system before the alarm siren sounds if for instance they have pressed the wrong button To delay sounding enter EJEJEHNE I EE ENE IC Tee siren n from 0 to 60s Factory setting 0 s 4 2 Setting the sounding parameters 4 2 1 Duration of alarm sounding To modify the duration of sounding enter EJEJ ENE EEG ENE EE SE siren n from 20 to 180s Factory setting 90 s 4 2 2 Level of sounding To modify the level of sounding enter Le La LY Je JGJOJBIBOL
14. eletion of parameters 113 5 Installing the siren eranvrnnnvnnnvnnnnen 114 5 1 Choosing the best place to install the Siren 114 5 2 Testing the radio range 114 5 3 Fixing the siren in place 115 6 Performing a real test nnnnvnnnnnn 116 7 Maintenance mss easvnnnnvnnnnnnnnnnnnnnnnenne 117 7 1 Fault indications pp 117 7 2 Changing the battery 118 8 Summary of parameters 118 9 Technical data ee 121 The user must not attempt to access the siren s internal parts except areas described in this manual If the user does access these parts the product guarantee will be considered null and void and DAITEM shall not be held responsible for any problems Touching the siren s internal parts and or electronic components can damage the product Furthermore the siren is designed in such a way that these parts and components do not need to be accessed for operation or maintenance purposes IMPORTANT the siren s sounding level can cause hearing disorders Take the necessary precautions before testing the product 1 Introduction IMPORTANT e Some functions are only available with versions 2 0 0 or later press S D 1 3 _ Jon the control panel keypad to check the version The operating differences with former ranges are described in the compatibility booklet available in the Daitem installers section at www d
15. eral alarm system groups enter GORE GJE BBDO BIT Eo Le JP siren n groups from 1 to 8 depending on the type of control panel Factory setting all groups Example to allocate siren n 1 to Group 2 and Group 3 enter RBG IBN BB BI BD 4 18 Type of indication 5 vocal messages are available in order to personalise indications The messages are as follows N 1 Barking N 2 Beware Intrusion alarm enabled N 3 Beware Protected zone N 4 Intruder detected N 5 Intrusion Alarm triggered 4 18 1 For warnings To modify the type of warning indication enter Lx JL SEA ale IL Je J siren n 0 disabled 4 vocal message n 1 flashing 5 s 1 sounding 2 s 5 vocal message n 2 flashing 5 s 2 sounding 6 vocal message n 3 flashing 5 s Factory setting 3 and flashing 5 s 7 vocal message n 4 flashing 5 s 3 flashing 5 s 8 vocal message n 5 flashing 5 s 4 18 2 For deterrence To modify the type of deterrence indication enter Le Le ITS JC CZ CS I J siren n 0 disabled 4 vocal message n 1 flashing 5 s 1 sounding 6 s 5 vocal message n 2 flashing 5 s 2 sounding 6 vocal message n 3 flashing 5 s Factory setting 2 and flashing 5 s 7 vocal message n 4 flashing 5 s 3 flashing 5 s 8 vocal message n 5 flashing 5 s 4 18 3 For prealarms To modify the type of prealarm indication enter x xl IC Je CZ ICS L
16. hould preferably be placed e at a height e far away from possible sources of electrical interference electricity meter telephone box etc Never fix the siren to a metal wall 5 2 Testing the radio range Before fixing the siren in place test its radio range in the chosen location by putting it there If the test is satisfactory fix the siren in place Otherwise move it to a different location 1 Press the test button 2 The control panel issues the message bip siren X 5 3 Fixing the siren in place The siren can be fixed in two different ways 1 Remove the tamper mechanism OR Remove the two fixing washers located washer located at the back of the at the back of the base Remove any base extra parts from the washers e Remove the tamper washer located at the back of the base HIO J D ol Detachable EK washers ya Be Detachable Detachable A tamper tamper AN mechanism mechanism JN washer washer e For the siren to be installed there must e For the siren to be installed there must be
17. ial 1 or 2 bip Armed Partial 1 or bip Armed Partial 2 Disarm group bip Off Group X Arm Presence mode bip Armed Presence Alarms Intrusion when bip bip bip bip intrusion Group X presence mode armed Entry delay bip bip bip bip protection active Fire alarm loud sounding for 15 s then Fire Alarm alternating Warning N 1 Barking N 2 Beware Intrusion alarm armed depending Deterrence N 3 Beware Protected zone on chosen Preal N 4 Intruder detected parameters rea arm N 5 Intrusion Alarm triggered Changing User test mode bip TEST MODE siren modes Installation mode bip INSTALLATION MODE User mode bip USER MODE 103 Example The system is in Armed Partial 2 mode but the siren has a battery fault When the system status query order is sent from the keypad or remote control the control panel and siren issue the following vocal messages Bip System status Armed p Partial 2 bip 12703 at 12 00 Fault PR AmE ea Voltage Remote_Control_Unit 1 p 2 SY 2 Preparing the siren 2 1 Tooling required lt gt 6mm V g amp Pa IMPORTANT the fixing screws and wall plugs are not supplied 2 2 Opening the siren and connecting the power supply 1 Insert a screwdriver into 2 Place the siren o
18. n Spanish Dutch English 109 Sounding level 4 siren n 19 0 normal normal quiet 107 Triggering upon intrusion 4 siren n 20 1 single or confirmed disabled single or confirmed intrusion 2 confirmed intrusion only O 2 9 SRON SO 109 Protection system armed indication 4 siren n 21 1 disabled disabled sounding 109 Alarm indication in armed presence mode 4 siren n 22 2 loud sounding 155 disabled quiet sounding 4 beeps 2 loud sounding 15 s 3 vocal message 4 quiet sounding 4 beeps and flashing loud sounding 15 s and flashing vocal message and flashing flashing 0 1 2 vocal message 0 1 oa 109 Triggering upon communication network interruption mat 496 2 0 disabled disabled loud sounding triggered if the O N Oo system is totally armed 2 loud sounding triggered 24 24 109 Radio tamper 4 siren n 27 1 enabled disabled enabled 110 Indication of break in following intrusion 4 siren n 35 0 disabled disabled enabled enabled 24h 110 Visual localisation of flashing following intrusion 4 siren n 36 0 disabled disabled enabled 2 h enabled 48 h N O N 0ol 0o 110 Allocation of a siren to one or several intrusion groups
19. n a flat surface remove the base the bottom right hand by inclining it at a 45 angle A corner between the base A and pull it downwards B and the siren and apply pressure to open the siren 3 Lift up the screw cover and remove the 4 Guarantee sticker screw from its slot Remove the pre cut part of the sticker and stick it to the guarantee certificate in the user manual supplied with the control panel If you are adding the siren to an existing system use the guarantee sticker provided with this Screw product cover SH424AX A12260A0963C O EJ VY SH424AX cotersurcort PEER N i J A12260A0963C oi 5 Position the power pack on the guide Ga N ra Guarantee i sticker 6 Slide the power pack to the left until it is locked into place t Unlocking key Locking screw and battery cover screw 7 Reposition the battery cover and screw 8 Position the locking screw in its slot it in place using one of the screws A Locking screw slot Screw slot
20. nother language according to the user s nationality To do this enter CII GC JG JD IC JC Ie ae siren n 0 French 3 Spanish 1 Italian 4 Dutch Factory setting 0 2 German 5 English 4 9 Triggering upon intrusion The alarm is factory set to be triggered as soon as an intrusion is detected This function can be deactivated or activated for intrusion confirmed indications only To do this enter La Joe EAL JL Ji Le JO JL JL JL JL siren n 0 disabled 1 single or confirmed intrusion Factory setting 1 2 confirmed intrusion only 4 10 Protection system armed indication When this function is enabled the siren indicates that the system is armed either by issuing a series of 4 beeps or the voice message bip bip bip bip Protection Active The function is not enabled by default x x TY ICID Joe be Je J GP siren n 0 disabled rade 1 quiet sounding bip bip bip bip Factory setting 0 2 vocal message bip bip bip bip Protection Active 4 11 Alarm indication in armed presence mode The siren is factory set to sound loudly for 15 s in case of intrusion This function can be modified To do this enter Lx Le EAL JL elele Jie siren n 0 disabled 4 quiet sounding 4 beeps and flashing 5 s 1 quiet sounding 4 beeps 5 loud sounding 15 s and flashing 15 s Fact tting 2 2 loud sounding 15 s 6 vocal message bip bip bip bip dd Seng 3 vocal message bip bi
21. p intrusion group x and flashing 5 s bip bip intrusion group x 7 flashing 15 s 4 12 Triggering following a communication network interruption When this function is enabled loud sounding can be triggered except when parameter 26 is set at 0 LaLa Le JL Jie Lele JE JL IL Se siren n 0 disabled 1 loud sounding triggered if the system is totally armed Factory setting 0 2 loud sounding triggered 24 24 109 4 13 Radio tamper If the radio links are deliberately tampered with the siren is triggered To activate or deactivate the radio anti tamper system enter x x HJ llel JP siren n 0 disabled 1 enabled Factory setting 1 4 14 Duration of flashing To modify the duration of flashing enter Cale JIG Jo CS IJ IC Ie siren n from 1 to 60 min Factory setting 15 min 4 15 Indication of break in following intrusion The break in indication function lets a neighbour or correspondent know that an intruder is still on the monitored premises When intrusion occurs the strobe is activated continuously After a period of 3 minutes without intrusion the flashing becomes discontinuous on for 6 seconds off for 6 seconds indicating that there is no intruder on the premises If the intruder returns the strobe is reactivated continuously once more see diagram To modify the break in indication enter Cee I J ICS IS IPL BR siren n 0 disabled 1 enabled
22. reak in indication enabled 3 min l l 2 min l l 2h y Visual localisation enabled 2 h gt gt 2h 5 min Duration of flashing 3 min VE TTT A AE DYTT vea oealiaton enabled 48 n lt gt gt 72h 3min T Flashing On 6 s Off 6 s Continuous flashing IT TT Flashing on SA IMPORTANT e If the break in indication function parameter 35 and or the visual localisation function parameter 36 is are activated the installer should be aware that this will use up the batteries at a faster rate than usual when the complete indication cycle is triggered see the table below for the power pack battery life according to selected parameters e When parameters 35 and or 36 are selected with a long duration indication value value 2 we recommend changing the power pack on a yearly basis Power pack battery life according to the programming of parameters 35 and 36 Parameter 35 break in indication function 0 1 2 5 years 5 years 2 years 10 complete 8 complete 2 complete activations year factory activations year activations year kid 36 5 years 5 years 2 years localisation 7 complete 4 complete 2 complete function activations year activations year activations year 2 years 2 years 2 years 2 complete 2 complete 1 complete activations year activations year activation year 4 17 Allocation of siren to an alarm group To allocate the siren to one or sev
23. the year Radio links TwinBand 400 800 MHz Supervision Radio lithium power pack tamper Operating temperature 25 C to 70 C Tamper protection against e opening e removal Degrees of mechanical protection IP 54 IK 08 WxHxD 248 x 248 x 84 mm Weight 2 5 kg with battery Security grade grade IV according to standard EN 50131 4 Environmental class To obtain advice when installing your system or before returning equipment please contact the Daitem technical support team see telephone number at the back of the alarm system installation manual or check the web site at www daitem co uk A team of qualified technicians will advise you what to do class IV according to standard EN 50130 5 DECLARATION OF CONFORMITY GB C Manufacturer Hager Security SAS 13 Address F 38926 Crolles Cedex France Product type Siren with vocal messages and flashing strobe Trade mark Daitem We declare under our sole responsibility that the product to which this declaration relates is compliant with the essential requirements of the following directives R amp TTE directive 99 5 EEC Low voltage directive 2006 95 EC ROHS directive 2002 95 EC in compliance with the following harmonised European standards Product references SH424AX SH425AX SH426AX SH424Al EN 300 220 2 V3 2 1 x x x x EN 50130 4 95 A1 98 A2 2002 x x x x EN 55022 amp 55024 20
24. thium pack 6 close the siren and put it back on its base 7 switch the control panel to user mode IL IL IL JL JO IL JC installer code 8 test triggering 8 Summary of parameters Parameter description Parameter setting Factory Possible values Page sequence parameter Delayed sounding 4 sirenn 3 0 immediate from 0 to 60 s 107 upon intrusion 0 immediate Sounding duration 4 siren n 4 90s from 20 s to 180 s 107 Flashing duration 4 siren n 5 15 min from 1 to 60 min 110 Type of sounding 4 siren n 10 external 0 internal 108 1 external Sound level of disarm 4 siren n 11 4 average from 1 to 8 108 arm indications Transfer of disarm arm 4 siren n 12 0 disabled 0 disabled 108 indications 1 sounding 2 vocal message 3 sounding and flashing 4 vocal message and flashing 5 flashing Indication of audible 4 siren n 13 0 disabled 0 disabled 108 signals and door bell 1 enabled Validation of radio link 4 siren n 15 0 on one of 0 validation 108 in installation mode 2 bands on 1 of 2 bands 1 validation on 2 bands Parameter description Parameter setting sequence Factory parameter Possible values Page Selection of speech synthesis system language 4 siren n 17 0 French French Italian Germa

Download Pdf Manuals

image

Related Search

Related Contents

Rapport du médiateur de l`éducation nationale et de l`enseignement  Dusk to Dawn Light Control  Land Pride FDR2572 User's Manual  none Magnetic Mail Slot Door, White Instructions / Assembly : Free Download, Borrow, and Streaming : Internet Archive  イベント情報(PDF:289KB)    TP3993202 2006 LV RSE V70 V70R XC70  GilAir3-5  