Kane Kane_450_Quick_Reference_Guide Boiler Manual
Contents
1. SETUP SET FUEL NAT GAS L OIL PROPANE BUTANE LPG PELLETS Select the combustion efficiency calculation required NEC gt G N nett eff G gross eff C for condensing boilers SET TIME Uses Military time 7am 07 00 7pm 19 00 SET DATE UK users select DD MM YY then set the date C amp gt F C F PPM lt gt MG_ PPM MG M UK users should set to PPM O2 REF NO YES UK users should set to NO LANGUAGE various languages PRESSURE SMOOTH OFF fast response ON slow response RESOLVE HIGH LOW selects the number of decimal places PS UNITS mBar mmH2O Pa kPa PSI mmHg hPa InH2O STORE VIEW View logged readings AUTO STO See KANE 450 REPORTS page DEL ALL NO YES REPORT SCREEN See KANE 450 REPORTS page CONTRAST Factory setting is 04 AUX UK users normally set to display the current fuel type HEADER sets printout header 2lines 20 characters per line SERVICE CODE Leave set at 0000 To EXIT the MENU at any time simply move the rotary switch to any position other than Menu Any changes that have not been entered will be ignored KANE450 REPORTS AUTO STORE stores up to 255 tests From the menu select STORE AUTO STORE YES Set the time interval in seconds between logs The analyser starts logging as soon as you exit the menu and stops when you select STORE AUTO STORE NO To view the results select STORE VIEW then enter the log number
2. C INLT C NETT C EFF N PRS mBAR LOSSES XAIR CO CO2 TIGHTNESS TEST LOG 05 TIME 15 40 03 08 05 PRS_1 mBAR 20 110 PRS_2 mBAR 19 998 DURATION MINS 3 00 Appliance TEMP TEST LOG 02 TIME 16 37 03 08 05 FLOW C 48 3 RETURN C 39 7 NETT C 8 6 ROOM CO TEST LOG 01 TIME 09 20 04 08 05 TEST 0 1 14 Io COT MAXIMUM CO CO pom To print a displayed REPORT hold the Print key for 2 seconds SUDO na soa Stock No 18326 2
3. is Document Has Been Provided d By gt KANE450 QUICK REFERENCE GUIDE INSTRUMENT FEATURES AND KEYPAD T wee UC WW 3 Infra red printer emitter and torch light Socket for gas ig atk i leak detector Line select LED s ico ly Doe Trou Menu controls z i Scroll up down Enter Function buttons x 4 See below for details Rotary switch Particle filter Water trap Battery charging indicator Analyser connections oe See diagram overleaf Flue gas inlet PUMP CAL PRESSURE ON OFF Turns the pump ON OFF Turns the analyser ON OFF Press for 2 seconds to zero the pressure sensor PRINT BACKLIGHT LINE SELECT FREEZE Press to print live or frozen Press to select active line on data Press again to abort display as indicated by LED s Press for 2 seconds to switch Press for 2 seconds to HOLD backlight amp torch ON OFF Press longer to LOG Supplied By www heating spares co Tel 0161 620 6677 This Document Has Been Provided By Please Visit www heatingspares co or call us on 0767 620 6677 For spares at Discounted Prices Temperature connections Flue probe temperature 11 Battery charger connection Inlet temperature T2 Flue gas inlet Water trap drain Pressure connections with rubber plug P 1 P2 differential BEFORE USING ANY ANALYSER CHECK THAT Calibration date ha
4. required Use the rotary dial and line selector to view the readings as normal Use scroll up down to view other log numbers To delete select DEL ALL YES PRESSURE stores up to 8 tests From the menu select REPORT PRESSURE TEST Press the Pump key to zero the pressure sensor CONNECT the pressure hose to pressure connection P1 Press Enter to start the 1 minute stabilization period Press Enter again to start the 2 minute tightness test To view the results select REPORT PRESSURE VIEW Use scroll up down to view other log numbers TEMPERATURE stores up to 8 tests From the menu select REPORT TEMP TEST CONNECT the thermocouples flow to Tf return to Ti Press Enter once to view readings and once more to log To view the results select REPORT TEMP VIEW Use scroll up down to view other log numbers To exit press Enter To delete select DEL ALL YES ROOM CO stores up to 8 tests From the menu select REPORT ROOM CO TEST The pump will run and the analyser will log the CO reading every minute for 15 minutes To view the results select REPORT ROOM CO VIEW Use scroll up down to view other log numbers Use Enter to view each reading within the ROOM CO TEST To exit use rotary switch To delete select DEL ALL YES To exit press Enter To delete select DEL ALL YES TEST 11 DATE 03 08 05 TIME 16 27 32 FUEL NATU GAS O2 CO2 CO ppm FLUE
5. s not expired Particle filter is not dirty inside Water trap and flue probe hose are empty of water Water trap is fitted correctly to the instrument including the drain plug Flue probe hose is connected properly to the flue gas inlet Flue probe temperature plug is connected into T1 connection Please read the Safety Warnings in the User Manual USING THE ANALYSER With the flue probe in fresh air at the same temperature as the boiler inlet air press 1P The analyser will auto calibrate for 20 to 30 seconds and then a set of readings will be displayed In fresh air the O2 reading should be 20 9 0 1 and the CO reading should be zero Check the battery status by selecting Bat on the rotary switch and select the correct fuel via the menu See Using the Menu Insert the tip of the probe into the centre of the flue After approximately 60 seconds the readings should stabilise A printout can be produced if required by pressing Qe SETTING UP THE DISPLAY Any four parameters can be displayed simultaneously Press GD to move the line select LED to the line you wish to change then use the rotary switch to select the new parameter you require To change other lines just repeat the procedure Supplied By www heating spares co Tel 0161 620 6677 USING THE MENU select Menu on the rotary switch and navigate using the function buttons Scroll up V Scroll down MAIN MENU SUB MENU OPTIONS COMMENTS