RI Series Real-Time Operating System User`s Manual: Message

image

Contents

1. Document Name Document No RI Series Start R20UT0751E Message This manual RI850V4 V2 xx xx Coding R20UT2889E Debug R20UT2890E Analysis R20UT2891E RI600V4 Coding R20UT0711E Debug R20UT0775E Analysis R20UT2185E RI600PX Coding R20UTO964E Debug R20UT0950E RI78V4 V2 xx xx Coding R20UT3375E Debug R20UT3374E Analysis R20UT3373E RI850V4 Coding R20UT0515E Debug R20UT0754E Analysis R20UT0517E RI850MP Coding R20UT0519E Debug R20UT0755E RI78V4 V1 xx xx Coding R20UTO511E Debug R20UT0753E Analysis R20UT0513E Caution The related documents listed above are subject to change without notice Be sure to use the latest edition of each document when designing All trademarks or registered trademarks in this document are the property of their respective owners TABLE OF CONTENTS CHAPTER 1 GENERAL 6 CHAPTER 2 MESSAGE FORMATS 7 2 1 When Not Using RI600V4 RIGOOPX Configurator 7 2 2 When Using RI600V4 RIGOOPX Configurator 7 CHAPTER 3 MESSAGES 8 3 1 Internal Error 9 3 2 Fatal Errors 10 3 3 Abort Errors 21 3 4 Information 24 3 5 Warnings 25 RI Series CHAPTER 1 GENERAL CHAPTER 1 GENERAL This manual describes the message that tools offered in real time OS package output The message is output to Output panel or Message dialog box etc Remark See CubeSuite Integrated Development Environment User s Manual Message f
2. Explanation This is a message notifying the user of a warning It is normal W1136011 Message The register mode is multiple defined in CF file and reg option xxx assumed Explanation This is a message notifying the user of a warning It is normal W1136012 Message The value of maxint differs from the value defined in the device file the value defined in the device file is used Explanation This is a message notifying the user of a warning It is normal W1136013 Message Memory area xxx is not used so information of xxx is not output Explanation This is a message notifying the user of a warning It is normal W1137003 Message The interval time of a cyclic handler was rounded up result xxx Explanation This is a message notifying the user of a warning It is normal W1137004 Message The initial interval time of a cyclic handler was rounded up result xxx Explanation This is a message notifying the user of a warning It is normal W1139000 Message Path or file is not exist xxx W1151000 Message The setup of the proparty is not reflected in the load module Build the program it will be solved this warning Explanation Since the program was not rebuilt after the property was set or modified the load module is not consistent with the property setting This message will be shown for example when a load module for hardware tracing is loaded after the
3. File name xxx is duplicated F1131008 Message Option xxx needs parameters Action by User Check the option F1131009 F1131010 F1131011 F1131014 F1131015 Message RI850V4 V1 xx xx RI850V4 V2 xx xx The parameters xxx is illegal Action by User RI850V4 V1 xx xx RI850V4 V2 xx xx Check the parameter Message RI850MP Illegal parameters xxx Action by User Message Action by User Message Action by User Message Message RI850MP Check the parameter The option xxx is Illegal Check the option Illegal format is in command file Check the contents of acommand file Path or file name is too long xxx File xxx is not a supported file to convert F1131016 Message A described device xxx is not supported F1131017 Message The size of the command xxx file is too big F1131020 Message Cannot open command file Explanation The specified command file could not be opened Otherwise the specified command file name is not valid Action by User Check whether the specified command file exists or whether the command file name is correct F1131021 Message RI78V4 V1 xx xx Usage CF78V4 command file i lt SIT file gt ni dc lt C header file gt ndc da lt ASM header file gt nda V help lt CF file gt RI78V4 V2 xx xx Usage CF78
4. Message Exception code xxx is out of range Action by User Check the specified exception code E1134003 Message Number of maximum handler is out of range xxx Action by User Check the number of interrupt handlers E1134004 Message Undefined Memory area xxx Action by User Check the definition of memory area E1134005 Message RI78V4 V1 xx xx RI78V4 V2 xx xx One of TA_HLNG or TA_ASM must be defined as attribute in xxx Action by User RI78V4 V1 xx xx RI78V4 V2 xx xx Specify either TA_HLNG or TA_ASM Message R20UT0756EJ0105 Rev 1 05 Sep 30 2015 RI850V4 V1 xx xx RI850V4 V2 xx xx One of TA_HLNG or TA_ASM must be defined as attribute in Keyword xxx ENESAS Page 12 of 31 RI Series E1134006 Message CHAPTER 3 MESSAGES Attribute yyy is not defined together in Keyword xxx Action by User Specify either xxx or yyy E1134007 Message One of TA_TFIFO or TA_TPRI must be defined as attribute in Keyword CRE_MTX Explanation Specify either TA_TFIFO or TA_TPRI E1134008 Message One of TA_MFIFO or TA_MPRI must be defined as attribute in xxx Action by User Specify either TA_MFIFO or TA_MPRI E1134009 Message Neither TA_INHERIT and TA_CEILING may not be specified in this version Action by User Check the specified E1134011 Message
5. Check the device file F1139011 Message File read error xxx Explanation File xxx cannot be read Action by User Check if the specified file exists Alternatively check whether the file name is correct or whether the file name is specified with the valid number of characters F1139013 Message File write error xxx Explanation File xxx could not be opened Action by User Check whether the file is write enabled or whether the disk is full Alternatively check if the number of characters for the specified file name or output file name converted to an absolute path is valid F1139015 Message RI850V4 V1 xx xx RI850V4 V2 xx xx Cannot execute Preprocessor Action by User RI850V4 V1 xx xx RI850V4 V2 xx xx Check the pass of a preprocessor and the option Message RI850MP Cannot execute Preprocessor xxx F1139016 Message Too many errors F1139017 Message File name has already existed xxx F1139020 Message Not enough memory Explanation The available memory is insufficient Action by User The available memory is insufficient The available memory is insufficient to analyze the activation option command file or to analyze the system configuration file Increase the memory capacity available for CF78V4 by quitting any applications that are not in use F1139100 Message
6. RI850V4 V2 xx xx PEID xxx is not defined in the device file Explanation RI850V4 V2 xx xx The specified PEID xxx is not defined in the device file Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 RI850V4 V2 xx xx Check the PE number as specified peid option ENESAS Page 22 of 31 RI Series CHAPTER 3 MESSAGES F1139101 Message RI850V4 V2 xx xx Cannot read xxx in the device file Explanation RI850V4 V2 xx xx Cannot read the information xxx from the device file Action by User RI850V4 V2 xx xx Renews the latest device file or reconsiders the specified option F1139900 Message RI850V4 V1 xx xx RI850V4 V2 xx xx CF850V4 internal error xxx Action by User RI850V4 V1 xx xx RI850V4 V2 xx xx Please contact your vendor or your Renesas Electronics overseas representative Message RI850MP CF850MP internal error xxx Action by User RI850MP Please contact your vendor or your Renesas Electronics overseas representative R20UT0756EJ0105 Rev 1 05 ENESAS Page 23 of 31 Sep 30 2015 RI Series CHAPTER 3 MESSAGES 3 4 Information Table 3 4 Information M1120010 Message The path that the output folder before it was changed has been set Include Path of Build Tool Do you want to remove the path from Include Path of Build Tool R20UT0756EJ0105 Rev 1 05 RENESAS Page 24 of 31 Sep 30 2015 R
7. Renesas Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document No license express implied or otherwise is granted hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from such alteration modification copy or otherwise misappropriation of Renesas Electronics product Renesas Electronics products are classified according to the following two quality grades Standard and High Quality The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots etc High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems and safety equipment etc Renesas Electronics products are neither intended nor a
8. RI78V4 V2 xx xx The specified numeric value is too large to be processed within CF78V4 Action by User Message RI78V4 V1 xx xx RI78V4 V2 xx xx Specify a numeric value within the 32 bit data range RI850V4 V1 xx xx RI850V4 V2 xx xx Integer overflow xxx Explanation RI850V4 V1 xx xx RI850V4 V2 xx xx The specified numeric value is too large to be processed within CF850V4 Action by User RI850V4 V1 xx xx RI850V4 V2 xx xx Specify a numeric value within the 32 bit data range E1132003 Message Keyword xxx is not defined Action by User Check the definition of the keyword E1132004 Message RI850V4 V1 xx xx RI850V4 V2 xx xx Memory area xxx cannot be specified for system stack Action by User RI850V4 V1 xx xx RI850V4 V2 xx xx Specify the memory area that can be specified Message RIS50MP Memory area xxx cannot be specified for system stack Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 RI850MP Review the format of system stack information SYS_STK ENESAS Page 11 of 31 RI Series E1132010 Message CHAPTER 3 MESSAGES RI850V4 V1 xx xx RI850V4 V2 xx xx One line is too long Action by User RI850V4 V1 xx xx RI850V4 V2 xx xx Revise the number of characters of each item and do 1 line within 16384 character E1133005 Message Keyword xxx is alrea
9. Gu Seoul 135 080 Korea Tel 82 2 558 3737 Fax 82 2 558 5141 2015 Renesas Electronics Corporation All rights reserved Colophon 4 0 RI Series ENESAS Renesas Electronics Corporation R20UT0756EJ0105
10. Total memory size xxx that is allocated in the memory area yyy exceeds defined size zzz Action by User Reduce the total size of the memory area yyy so as not to exceed the maximum size E1134016 Message Start address xxx is not 2 bytes alignment Action by User Check the start address E1134018 Message Illegal memory area xxx E1134020 Message RI850V4 V1 xx xx RI850V4 V2 xx xx xxx yyy bigger than maximum 255 was set Action by User Message RI850V4 V1 xx xx RI850V4 V2 xx xx Check the value of keyword RI850MP Xxx yyy bigger than maximum zzz was set Action by User RIS50MP Check the value of keyword E1134021 Message Action by User RI78V4 V1 xx xx RI78V4 V2 xx xx cyctim xxx smaller than minimum yyy was set RI78V4 V1 xx xx RI78V4 V2 xx xx For the activation cycle for the cyclic handler specify a value from 1 to 4294967295 Oxffffffff Message RIS50MP xxx yyy smaller than minimum zzz was set E1134022 Message Memory area size of fixed sized memory pool block count xxx block size yyy is out of range Action by User Specify the memory block count and block size so that the memory area size of the fixed sized memory pool calculation result of memory block count x block size will fall within the range of 4 to 65534 Oxfffe E1134025 Messag
11. is out of range xxx Action by User Check the number of maximum interrupt factor E1134136 Message Cyclic time of system time is illegal xxx Action by User Check the specified value at cyclic time E1134302 Message Task extension information is out of range exinf Action by User Specify a value from 0x0 to Oxfffff for the task extension information ext_inf E1134303 Message Function address xxx is out of range E1134304 Message Task stack size is out of range xxx Action by User Set the task stack size to a value from 0 to 65534 Oxfffe E1134401 Message Initial semaphore number xxx is out of range Action by User Set the number of initial resources for semaphore to a value from 0 to 127 E1134901 Message Block size xxx of fixed sized memory pool is out of range Action by User Specify a value from 4 to 65534 Oxfffe for the block size of the fixed sized memory pool E1134902 Message Block count xxx of fixed sized memory pool is out of range Action by User Specify a value from 1 to 16383 Ox3fff for the memory block count of the fixed sized memory pool E1135100 Message The interrupt source name xxx is not defined in the device file Action by User Check the specified value at cyclic time E1135500 Message Illegal calculation A
12. C 0 D 0 lt 5 D ENESAS RI Series Real Time Operating System User s Manual Message Target Tool RI78V4 RI850V4 RI850MP RI600V4 RI600PX All information contained in these materials including products and product specifications represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp without notice Please review the latest information published by Renesas Electronics Corp through various means including the Renesas Electronics Corp website http www renesas com Renesas Electronics www renesas com Rev 1 05 Sep 2015 10 11 12 Notice Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information Renesas Electronics has used reasonable care in preparing the information included in this document but Renesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein
13. Check the specified function code E1150000 Message The file filename does not exist Action by User Specify a correct file name E1150001 Message Reading analysis data failed The file type is invalid Explanation The format specified for the file is incorrect or the file may have been corrupted Action by User Specify the correct format for the file containing the results of analysis and read it again E1151000 Message Could not operate the hardware trace method Check whether the debugging tool has a trace function Action by User Check whether the debugging tool has a trace function E1151001 Message Could not switch the trace of task analyzer on The point trace is full Action by User When using the debug tool to specify an event invalidate or delete the point trace E1151100 Message Could not find the target to jump Explanation Symbol information was not included Action by User Use a load module which has symbol information E1152000 Message The value is illegal Explanation The input value includes illegal characters Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Specify characters for which input is allowed ENESAS Page 16 of 31 RI Series E1152001 Message CHAPTER 3 MESSAGES The value is out of range Explanation The input value e
14. I Series CHAPTER 3 MESSAGES 3 5 Warnings Message Table 3 5 Warnings xxx is already defined Explanation xxx has already been defined The definition is ignored Action by User Resolve the multiple definition Message The maximum ID of the object is larger than maxdefine xxx Explanation The value of the maximum ID of the defined object is selected Message Xxx is not defined Explanation The definition of xxx is omitted the setting in the default system configuration file is used Action by User Check RI600V4 RI600PX Real Time Operating System User s Manual Coding for the default system configuration file settings Message Timer counter value is less than your setting time Explanation It is not possible to create the specified base clock interrupt cycle time system tic_nume system tic_deno ms accurately The actual base clock interrupt cycle time is shorter than the specified cycle Action by User Consider making the base clock interrupt cycle time longer W1110010 Message Debugger is running Explanation The debugger was operated while it was running Action by User Stop the debugger before operating W1110020 Message RTOS is not initialized Explanation The real time OS was manipulated before initialization Action by User Click Run to Position Where Real Ti
15. User Create the project again or re install the plug in E1132000 Message Illegal keyword or syntax error Explanation The keyword is illegal or there is a description error Action by User Check the description format of the system configuration file or command file R20UT0756EJ0105 Rev 1 05 Sep 30 2015 ENESAS Page 10 of 31 RI Series E1132001 E1132002 Message CHAPTER 3 MESSAGES RI78V4 V1 xx xx Keyword xxx is too longer than 24 characters Explanation RI78V4 V1 xx xx The keyword xxx is longer than the maximum value of 24 characters permitted for that keyword Action by User RI78V4 V1 xx xx Specify a keyword object name of 24 characters or less Message RI78V4 V2 xx xx RI850V4 V1 xx xx RI850V4 V2 xx xx Keyword xxx is too longer than 255 characters Explanation RI78V4 V2 xx xx RI850V4 V1 xx xx RI850V4 V2 xx xx The keyword xxx is longer than the maximum value of 255 characters permitted for that keyword Action by User RI78V4 V2 xx xx RI850V4 V1 xx xx RI850V4 V2 xx xx Specify a keyword xxx of 255 characters or less Message RI850MP Keyword xxx is too longer than yyy characters Action by User Message RI850MP Specify a keyword xxx of yyy characters or less RI78V4 V1 xx xx RI78V4 V2 xx xx Integer overflow Explanation RI78V4 V1 xx xx
16. V4 command file cpu lt Name gt devpath lt Path gt i lt SIT file gt ni dc lt C header file gt ndc da lt ASM header file gt nda V help lt CF file gt Explanation Because the specified activation option is not correct CF78V4 could not be executed Action by User Check the activation option F1131502 Message Option xxx is multiple defined Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Check the contents of a command file ENESAS Page 21 of 31 RI Series F1131505 Message CHAPTER 3 MESSAGES Output file names are the same xxx Explanation The output files system information table file system information header file for C lan guage or system information header file for assembly languages are specified with the same file name xxx Action by User Check if the file names specified with the i dc and da options are the same F1131506 Message It is necessary to specify the device file in the case of outputing entry file Action by User Check the specified the output option of the entry file or the device file F1133011 Message It failed to convert file xxx F1133020 Message Syntax too complecated Action by User Check the description of the system configuration file F1139002 Message Unknown device file format Action by User
17. anual This manual is intended for users who design and develop application systems using RH850 family RX family V850 family RL78 family and 78KOR microcontrollers products This manual is intended for users to understand the functions of real time OS RI Series RI78V4 V2 xx xx RI850V4 V2 xx xx RI600V4 RI600PX RI850V4 V1 xx xx RI850MP and RI78V4 V1 xx xx manufactured by Renesas Electronics described the organization listed below This manual consists of the following major sections CHAPTER 1 GENERAL CHAPTER 2 MESSAGE FORMATS CHAPTER 3 MESSAGES It is assumed that the readers of this manual have general knowledge in the fields of electrical engineering logic circuits microcontrollers C language and assemblers To understand the hardware functions of the RH850 family RX family V850 family RL78 family and 78KOR microcontrollers gt Refer to the User s Manual of each product Data significance Higher digits on the left and lower digits on the right Note Footnote for item marked with Note in the text Caution Information requiring particular attention Remark Supplementary information Numeric representation Decimal XXXX Hexadecimal OxXXXX Prefixes indicating power of 2 address space and memory capacity K kilo 210 1024 M mega 2 1024 Related Documents The related documents indicated in this publication may include preliminary versions However preliminary versions are not marked as such
18. ation The specified address xxx is outside the specifiable range Action by User Set the address value to a value from 0x0 to Oxfffff E1136013 Message Illegal value xxx Action by User Check the specifiable range of values E1136250 Message DOMAIN name xxx is not defined E1136251 Message DOMAIN with a PE xxx is not defined E1136252 Message SYS_STK necessary to a PE xxx is not defined E1136300 Message Task priority xxx is higher than max priority yyy Action by User Check the specified task priority E1136301 Message RI78V4 V1 xx xx RI78V4 V2 xx xx Task priority xxx is higher than the highest system priority 15 Explanation RI78V4 V1 xx xx RI78V4 V2 xx xx The specified initial task priority pri is higher than the highest system priority 15 Action by User RI78V4 V1 xx xx RI78V4 V2 xx xx Set the value of the initial task priority to a value from 1 to 15 Message R20UT0756EJ0105 Rev 1 05 Sep 30 2015 RI850V4 V1 xx xx RI850V4 V2 xx xx RI850MP Task priority xxx is higher than the highest system priority yyy ENESAS Page 15 of 31 RI Series E1136302 Message CHAPTER 3 MESSAGES RI78V4 V1 xx xx RI78V4 V2 xx xx Task priority xxx is lower than the lowest system priority 1 Explanation RI78V4 V1 xx xx RI78V4 V2 xx xx The sp
19. ction by User Check the specifiable range of values E1136000 Message Name xxx is already used in Keyword xxx Action by User Check the specified keyword E1136001 Message R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Exception code is reserved xxx ENESAS Page 14 of 31 RI Series E1136002 Message CHAPTER 3 MESSAGES Memory area xxx is already defined Action by User Check the specified memory area E1136009 Message Name xxx is already used Action by User Specify an object name that is not in use E1136010 Message RI78V4 V1 xx xx Symbol too long max 30 RI78V4 V2 xx xx Symbol too long max 4095 Explanation RI78V4 V1 xx xx The symbol name or object name is longer than the maximum value of 30 characters permitted for those names RI78V4 V2 xx xx The symbol name or object name is longer than the maximum value of 4095 charac ters permitted for those names Action by User RI78V4 V1 xx xx Specify a symbol name or object name of 30 characters or less RI78V4 V2 xx xx Specify a symbol name or object name of 4095 characters or less E1136011 Message Symbol xxx is already used Explanation The symbol name xxx is already defined Action by User Specify a symbol name that is not in use E1136012 Message Address xxx is out of range Explan
20. debugger or there is no real time OS incorpo rated in the target program Action by User Load the target program into the debugger If there is no real time OS incorporated in the target program do so E1110031 Message RTOS data may be corrupted Explanation The real time OS information is incorrect e g runaway program Action by User Make sure that the real time OS information of the target program is not corrupt E1110032 Message Queue information may be corrupted Explanation The real time OS information is incorrect e g runaway program Action by User Make sure that the real time OS information of the target program is not corrupt E1120040 Message Realtime OS used in the project is not installed Explanation The real time OS used by the existing project was not found for example it may have been uninstalled Action by User Make sure that the real time OS is correctly installed E1120041 Message RI850MP supports the 32 register mode only Explanation Displayed when the register mode of the project that uses RI850MP is changed besides 32 register mode Action by User Set the register mode to 32 register mode E1120050 Message Saving realtime OS build setting options failed Explanation Could not obtain save information because the internal information is corrupt Action by
21. dy defined Explanation The keyword xxx is already defined Action by User Define a keyword only once E1133006 Message Keyword xxx cannot be defined in DOMAIN E1133007 Message Keyword xxx cannot be defined out of DOMAIN E1133008 Message DOMAIN allocation is defined more than defined DOMAIN E1133009 Message DOMAIN allocation is defined less than defined DOMAIN E1133010 Message Number of PE is not defined E1133017 Message Task is not defined on any DOMAIN E1133018 Message Task is not defined E1133019 E1133020 E1133030 E1133031 E1134000 Message Too many Keyword xxx is defined Explanation Action by User Message Message Action by User Message Action by User Message Action by User There are too many definitions of keyword xxx Decrease the number of definitions of keyword so as not to exceed the maximum Too few Keyword xxx is defined Task xxx that is specified in task exception routine is undefined Make sure whether a specified task exists Task exception routine for the one task is multiple defined xxx Check the definition of the corresponding task exception routine Illegal maximum value xxx Check the specified value E1134001 Message Illegal exception code xxx Action by User Check the specified exception code E1134002
22. e Attribute xxx is not supported Action by User Check a specifiable attribute E1134026 Message Attribute xxx is not defined yyy Action by User Check the attribute and then specify xxx E1134030 Message XXX yyy is out of range Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Check the set value ENESAS Page 13 of 31 RI Series E1134100 Message CHAPTER 3 MESSAGES Illegal OS name xxx Action by User Check the OS name E1134101 Message Illegal OS version xxx Action by User Check the OS version E1134102 Message The number of lines exceeded the maximum Action by User Set the number of lines of the file to no more than 1000000 lines E1134110 Message Stack check flag is illegal Action by User Check the specified stack check flag E1134131 Message Illegal system stack size xxx Action by User Set the system stack size to a value from 0 to 65534 Oxfffe E1134132 Message Illegal maximum task priority xxx Action by User Set the value of maximum task priority information MAX_PRI to a value from 1 to 15 E1134134 Message Exception code for system timer xxx is out of range Action by User Check the exception code for system timer E1134135 Message Number of maximum interrupt factor
23. e by the military including but not limited to the development of weapons of mass destruction When exporting the Renesas Electronics products or technology described in this document you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations It is the responsibility of the buyer or distributor of Renesas Electronics products who distributes disposes of or otherwise places the product with a third party to notify such third party in advance of the contents and conditions set forth in this document Renesas Electronics assumes no responsibility for any losses incurred by you or third parties as a result of unauthorized use of Renesas Electronics products This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics 2012 4 Readers Purpose Organization How to Read This Manual Conventions How to Use This M
24. e character string message number O 4 digits message type 1 alphabetic character 2 See CubeSuite Integrated Development Environment User s Manual Message for details about the message type and the message number R20UT0756EJ0105 Rev 1 05 ENESAS Page 7 of 31 Sep 30 2015 RI Series CHAPTER 3 MESSAGES CHAPTER 3 MESSAGES This chapter describes the messages displayed by tools offered in real time OS package R20UT0756EJ0105 Rev 1 05 ENESAS Page 8 of 31 Sep 30 2015 RI Series CHAPTER 3 MESSAGES 3 1 Internal Error C1110030 Message Table 3 1 Internal Error Required process is not supported Explanation An internal error has occurred Action by User Please contact your vendor or Renesas Electronics R20UT0756EJ0105 Rev 1 05 Sep 30 2015 ENESAS Page 9 of 31 RI Series CHAPTER 3 MESSAGES 3 2 Fatal Errors E1110001 Message Table 3 2 Fatal Errors Cannot load DLL Explanation The package is not correctly installed or a required file has been deleted Action by User Please reinstall the real time OS package E1110010 Message Cannot connect to the debugger Explanation Cannot communicate with debugger for unknown reason Action by User Please contact your vendor or Renesas Electronics E1110020 Message RTOS is not loaded Explanation The target program is not loaded in the
25. eater than system system_IPL Message System timer s vector lt xxx gt conflict Explanation A interrupt_vector xxx has already defined for the CMT s vector when one of CMTO CMT1 CMT2 or CMTS is specified for clock timer Action by User Delete the interrupt_vector or change the clock timer setting Message lt xxx gt is already defined Explanation xxx is multiply defined Action by User Define xxx once only Message xxx yyy is already defined Explanation The ID number is multiply defined in yyy object xxx Action by User Ensure that ID numbers do not overlap Message Zero divide error Explanation Zero division expression Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Do not divide by zero ENESAS Page 17 of 31 RI Series Message CHAPTER 3 MESSAGES Can t specify F switch when os_int YES Explanation You cannot specify fast interrupts pragma_switch F for the kernel interrupt handler os_int YES Action by User Do not set the pragma_switch to F for kernel interrupts Set to a non kernel interrupt os_int NO for fast interrupts Message interrupt_vector xxx os_int must be YES Explanation Relocatable interrupt cannot be used as non kernel interrupt os_int NO when the kernel interrupt mask level system system_IPL is 15 Action by Use
26. ecified initial task priority xxx is lower than the lowest system priority 1 Action by User RI78V4 V1 xx xx RI78V4 V2 xx xx Set the value of the initial task priority xxx to a value from 1 to 15 Message RI850V4 V1 xx xx RI850V4 V2 xx xx RI850MP Task priority xxx is lower than the lowest system priority yyy E1136401 Message Initial semaphore number xxx is bigger than maximum semaphore number yyy Action by User Check the specified initial semaphore number E1137101 Message The interrupt source name xxx cannot be used when not defined in the device file not set cpu option Action by User Check the specified device file or exception factor E1137103 Message Handlers that has same exception code in the same PE cannot be defined Action by User Check the specified exception factor E1137104 Message Handlers that has same exception code xxx in the system cannot be defined E1137105 Message SVC Handlers that has same function code xxx in the system cannot be defined Action by User Check the specified function code E1137106 Message The Number of interrupt handler d is bigger than the number of interrupt factor d Action by User Check the specified function code E1137107 Message The exception code that is out of range is already defined Action by User
27. ettings Message Xxx is not defined Explanation 1 xxx is not defined 2 The definition of the object of the displayed number leaks This error occurs with 01004 E Action by User Message Action by User Message Action by User Message Explanation 1 Define xxx 2 Correct the ID number that caused error 01004 E You must define SYMBOL Specyfy symbol You must define NUMBER Specify numeric value Initial start task is not defined There is no task definition with task initial_start ON Action by User Define at least one task specified as ON in task initial_start Message Environment variable LIB600 not prepared Explanation Environment variable LIB600 is not defined Action by User Set environment variable LIB600 Message memory_object is not defined Explanation Any memory object is not defined Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Define at least one memory object ENESAS Page 20 of 31 RI Series 3 3 Abort Errors F1131000 Message CHAPTER 3 MESSAGES Table 3 3 Abort Errors Option xxx is not specified Action by User Make sure whether the configuration file input to an option is specified F1131001 Message Cannot open device file Action by User Make sure that the device file exists F1131003 Message
28. he writeable attribute of the specified path to enabled W1120032 Message The specified passing doesn t exist Action by User Change to an existing file name W1131013 Message Command file is nested Option in the command file is ignored Explanation The command file is nested The option in the command file has been ignored This is a message notifying the user of a warning It is normal W1131504 Message Option xxx became invalid by Option yyy W1132008 Message Not supported Keyword xxx is changed to a comment W1132009 Message Temporary exception code yyy was established as key word xxx W1133015 Message Service call xxx already defined W1134013 Message Reserved ID xxx must be 0 in this version 0 assumed Explanation This is a message notifying the user of a warning It is normal W1134014 Message Defined value xxx in the reserved area is ignored Explanation This is a message notifying the user of a warning It is normal W1134015 Message Explanation RI78V4 V1 xx xx RI78V4 V2 xx xx Value is aligned to 2 bytes result xxx RI78V4 V1 xx xx RI78V4 V2 xx xx The specified value is not a 2 byte boundary value CF78V4 rounds up the specified value to a 2 byte boundary value number to continue processing This is a message notifying the user of a warning It i
29. hire SL8 5FH U K Tel 44 1628 585 100 Fax 44 1628 585 900 Renesas Electronics Europe GmbH Arcadiastrasse 10 40472 D sseldorf Germany Tel 49 211 6503 0 Fax 49 211 6503 1327 Renesas Electronics China Co Ltd Room 1709 Quantum Plaza No 27 ZhiChunLu Haidian District Beijing 100191 P R China Tel 86 10 8235 1155 Fax 86 10 8235 7679 Renesas Electronics Shanghai Co Ltd Unit 301 Tower A Central Towers 555 Langao Road Putuo District Shanghai P R China 200333 Tel 86 21 2226 0888 Fax 86 21 2226 0999 Renesas Electronics Hong Kong Limited Unit 1601 1611 16 F Tower 2 Grand Century Place 193 Prince Edward Road West Mongkok Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2886 9022 Renesas Electronics Taiwan Co Ltd 13F No 363 Fu Shing North Road Taipei 10543 Taiwan Tel 886 2 8175 9600 Fax 886 2 8175 9670 Renesas Electronics Singapore Pte Ltd 80 Bendemeer Road Unit 06 02 Hyflux Innovation Centre Singapore 339949 Tel 65 6213 0200 Fax 65 6213 0300 Renesas Electronics Malaysia Sdn Bhd Unit 1207 Block B Menara Amcorp Amcorp Trade Centre No 18 JIn Persiaran Barat 46050 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 60 3 7955 9390 Fax 60 3 7955 9510 Renesas Electronics India Pvt Ltd N0 777C 100 Feet Road HALII Stage Indiranagar Bangalore India Tel 91 80 67208700 Fax 91 80 67208777 Renesas Electronics Korea Co Ltd 12F 234 Teheran ro Gangnam
30. ject to radiation resistance design Please be sure to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or systems manufactured by you Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations You should not use Renesas Electronics products or technology described in this document for any purpose relating to military applications or us
31. me OS Information Can Be Obtained and complete the initialization of the real time OS W1120010 Message Path name or File name is illegal Input the character that can be used Explanation The path or file name contains illegal characters Action by User Use valid characters W1120011 Message The number of characters that exceeds 259 characters cannot be specified Explanation More than 259 characters have been specified Action by User Reduce the number of characters W1120012 Message The number of characters that exceeds 247 characters cannot be specified Explanation More than 247 characters have been specified Action by User Reduce the number of characters W1120020 Message The system information table file name is the same as the entry file name Action by User Change the file name W1120021 Message The system information table file name is the same as the service call table file name Action by User Change the file name W1120030 Message The specified passing doesn t exist Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Change to an existing path name ENESAS Page 25 of 31 RI Series W1120031 Message CHAPTER 3 MESSAGES The specified path is read only Explanation The specified path is write protected Action by User Change t
32. or Output panel or Mes sage dialog box R20UT0756EJ0105 Rev 1 05 ENESAS Page 6 of 31 Sep 30 2015 RI Series CHAPTER 2 MESSAGE FORMATS CHAPTER 2 MESSAGE FORMATS This chapter describes the output formats of messages 2 1 When Not Using RI600V4 RIGOOPX Configurator The output format when not using the RI600V4 RIGOOPX Configurator is as follows 1 When the file name and line number information are included file name line number message type component number message number message 2 When the file name and line number information aren t included message type component number message number message Remarks 1 Following contents are output as the continued character string message type 1 alphabetic character C E F M W component number 11 message number 5 digits 2 See CubeSuite Integrated Development Environment User s Manual Message for details about the message type the component number and the message number 2 2 When Using RI600V4 RIG00PX Configurator The output format when RI600V4 RI600PX Configurator is operated is as follows 1 When the file name and line number are included file name line number message number message type message 2 When the line number aren t included file name 0 message number message type message 3 When the file name and line number aren t included message number message type message Remarks 1 Following contents are output as th
33. property of the program has been changed to software tracing mode Action by User Build the program R20UT0756EJ0105 Rev 1 05 ENESAS Page 27 of 31 Sep 30 2015 Revision Record Oct 01 2011 Description Summary First Edition issued Apr 01 2012 Added the following RIG00PX Added the following Internal error C1110030 Added the following Fatal error 01032 E 01033 E 01035 E Added the following Fatal error 02013 E Added the following Warning 03002 W Sep 01 2012 Added the following Fatal error E1150000 E1150001 E1151000 E1151001 E1151100 E1152000 E1152001 Added the following Warning W1151000 Mar 03 2014 Added the following RI850V4 V2 xx xx Mar 25 2015 Added the following RI78V4 V2 xx xx Sep 30 2015 Added the following Fatal Error F1139100 F1139101 RI Series User s Manual Message Publication Date Rev 1 00 Oct 01 2011 Rev 1 05 Sep 30 2015 Published by Renesas Electronics Corporation ENESAS SALES OFFICES Renesas Electronics Corporation http www renesas com Refer to http www renesas com for the latest and detailed information California Eastern Laboratories Inc 4590 Patrick Henry Drive Santa Clara California 95054 1817 U S A Tel 1 408 919 2500 Fax 1 408 988 0279 Renesas Electronics Europe Limited Dukes Meadow Millboard Road Bourne End Buckinghams
34. r Set os_int YES for all variable vector definitions interrupt_vector Message mailbox xxx max_pri yyy is bigger than system message_pri zzz Explanation The mailbox xxx max_pri setting yyy is greater than the system message_pri setting ZZZ Action by User Specify a value for mailbox max_pri that is no greater than system message_pri Message Neither system tic_nume nor system tic_deno is 1 Action by User Set 1 to either system tic_nume or tic_deno as CCC at least Message Symbols other than NO and NO are defined simultaneously Action by User You cannot specify symbols other than NO and NO simultaneously Message semaphore xxx initial_count is bigger than semaphore xxx max_count Explanation The initial_count setting in semaphore xxx is greater than the max_count setting Action by User Set initial_count to no greater than max_count Message Size of memorypool xxx is larger than VTMAX_AREASIZE Explanation The size of fixed sized memory pool must be lower than or equal to VTMAX_AREASIZE 256MB Action by User Set the value of memorypool xxx siz_block meorypool xxx num_block to no greater than 256 MB Message variable_memorypool xxx max_memsize is larger than 192MB 12 Explanation variable_memorypool max_memsize must be lower than or equal to 192MB 12 Action by User Set
35. s normal Message Explanation RI850V4 V1 xx xx RI850V4 V2 xx xx Value is aligned to 4 bytes result xxx RI850V4 V1 xx xx RI850V4 V2 xx xx This is a message notifying the user of a warning It is normal Message RI850MP Value is aligned to yyy bytes result xxx Explanation RI850MP This is a message notifying the user of a warning It is normal W1134016 Message The value xxx is assumed to be a set value Explanation This is a message notifying the user of a warning It is normal W1136003 Message Maximum number to make object must be a number of defined object or maximum number of ID xxx assumed Explanation This is a message notifying the user of a warning It is normal W1136005 Message The maximum priority level xxx is defined But set the maximum priority level to yyy because the task with initial priority pri2 is defined Explanation R20UT0756EJ0105 Rev 1 05 Sep 30 2015 xxx is defined as the maximum task priority however since yyy is already specified as the initial task priority the system continues processing assuming that yyy has been specified as the maximum task priority This is a message notifying the user of a warning It is normal ENESAS Page 26 of 31 RI Series CHAPTER 3 MESSAGES W1136010 Message The CPU type is multiple defined in CF file and cpu option xxx assumed
36. t Message Can t write open lt xxx gt Explanation The file xxx cannot be generated Action by User Check the read only attribute of the cfg600 or cfg600px output directory and output file Message Can t open lt xxx gt Explanation The file cannot be accessed in the directory indicated by environment variable LIB600 Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Make sure that the environment variable LIB600 setting and directory pointed to by LIB600 are correct ENESAS Page 19 of 31 RI Series Message CHAPTER 3 MESSAGES Can t open version file Explanation The version file cannot be found in the current directory or the directory indicated by environment variable LIB600 Action by User Make sure that the environment variable LIB600 setting and directory pointed to by LIB600 are correct Message Can t open default configuration file Explanation The default cfg file cannot be found in the current directory or the directory indicated by environment variable LIB600 Action by User Make sure that the environment variable LIB600 setting and directory pointed to by LIB600 are correct Message Can t open configuration file lt xxx gt Explanation The specified system configuration file xxx cannot be accessed Action by User Check for the system configuration file s
37. tick is too short Explanation The base clock cycle time decided by system tic_nume and system tic_deno is too short Action by User Make the base clock cycle time longer or higher clock timer_clock Message cyclic_handler phs_counter is larger than interval_counter Action by User Set cyclic_hand phs_counter to no greater than interval_counter Message start_address must be smaller than end_address Action by User When numeric value is specified as both memory_object start_addrsss and endaddress set start_address and end_address that it satisfies the fomula start_address lt and_address Message ACC and NOACC can t be specified at the same time Action by User Do not specify both ACC and NOACC at the same time Message task xxx domain_num yyy is bigger than maxdefine max_domain zzz Explanation The setting of yyy for task xxx domain_num exceeds the maxdefine max_domain set ting of zzz Action by User Set ask xxx domain_num to no greater than maxdefine max_domain Message Not enough memory Explanation There is not enough memory to execute cfg600 or cfg600px Action by User Please contact your vendor or Renesas Electronics Message Illegal argument gt lt xxx gt Explanation Failed to recognize xxx due to error in startup format Action by User Check the startup forma
38. uthorized for use in products or systems that may pose a direct threat to human life or bodily injury artificial life support devices or systems surgical implantations etc or may cause serious property damages nuclear reactor control systems military equipment etc You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application for which it is not intended Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for which the product is not intended by Renesas Electronics You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions Further Renesas Electronics products are not sub
39. variable_memorypool xxx max_memsize to no more than 192 MB 12 Message mutex xxx ceilpri is bigger than system priority Explanation mutex ceilpri must be lower than or equal to system priority Action by User Set mutex ceilpri to no greater than system priority Message xxx is not a multiple of y Explanation xxx must be multiple of y Action by User Set xxx to a multiple of y Message max_msgsz xxx is larger than mbf_size yyy 4 Explanation The setting of xxx for message_buffer max_msgsz exceeds the message_buffer mbf_size 4 setting of yyy 4 Action by User R20UT0756EJ0105 Rev 1 05 Sep 30 2015 Set message_buffer max_msgsz to no greater than message_buffer mbf_size 4 ENESAS Page 18 of 31 RI Series Message CHAPTER 3 MESSAGES variable_memorypool xxx max_memsize yyy is too large Max zzz Explanation The value yyy specified for variable_memorypool xxx max_memsize is too large The maximum value of the specified pool size variable_memorypool heap_size is zzz Action by User Set max_memsize to no more than zzz Message Time tick is too long Explanation The base clock cycle time decided by system tic_nume and system tic_deno is too long Action by User Make the base clock cycle time shorter or lower clock timer_clock Message Time
40. xceeds the range of values that can be input Action by User Check the range of values that can be input Message Syntax error Action by User Check your syntax Message Illegal xxx gt lt yyy gt Explanation The setting for definition name xxx is illegal Action by User yyy specified in xxx is invalid Please revise Message Unknown token gt lt xxx gt Explanation The specified strings xxx cannot be recognized as a definition name Action by User Correct the definition name for xxx Message Unknown xxx gt lt yyy gt Explanation The specified strings yyy as xxx cannot be recognized as a kerword Action by User Correct the kerword for yyy Message xxx s ID number is too large gt lt yyy gt Explanation ID number yyy specified in xxx is too large Action by User The ID number must be no greater than the number of objects that have been defined Message Task xxx s priority is too large gt lt yyy gt Explanation task xxx priority setting yyy is greater than system priority Action by User Set task priority to a value no greater than system priority Message clock IPL is too large gt lt xxx gt Explanation The clock IPL setting is greater than the system system_IPL setting Action by User Set clock IPL to a value no gr