Home
Automatic Leveling Rotary & Line Laser (RL4V)
Contents
1. DaveBell Automatic Leveling Rotary amp Line Laser ruv ELECTRONIC EQUIPMENT LIMITED For the purpose of long term use of this instrument we suggest you to read this instruction manual carefully before using it Contents 1 Features and Functions 2 User Safety 3 Nomenclature 4 Operation Instruction 5 Self Check and Calibration 6 Application Methods 7 Technical Specifications 8 Maintenance Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 1 Features and Functions LS 560 automatic leveling rotary and line laser can simultaneously project horizontal laser plane plumb line and plumb up amp down laser point Its extensive functions bring great convenience to set accurate horizontal and vertical and plumb references for indoors lay out and calibration This kind of product is featured by easy manipulation and wide applications e Able to simultaneously project 360 degree horizontal laser plane four vertical laser lines plumb up and plumb down points could formed 4 cross lines in right angle and plumb up amp down points e Vertical laser line could be switched to modulation status the laser line could be detected by a receiver e Laser rotation speed and area scan angle are changeable e Auto leveling the instrument will make laser flash and alarm sound if beyond tolerance e TILT mode has unbalance alarm function the laser
2. keypad of the main instrument light start to calibrate the accuracy of Y axis 3 Power off the instrument after the calibration is done Note 1 In order to make the last calibration effective you must power off the instrument after the said calibration and then power on it again 2 Y axis accuracy check is a necessity after Xaxis calibration and Xaxis accuracy check is also a necessity after Y axis calibration Instrument selfcalibration will not be fulfilled until both X axis and Y axis accuracy meet the requirement Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBell 6 Application Methods ie x X N O T ie gt 4 19 gt gt gt N O 12 gt 4 gt 4 LLJ To 00 a Yo S O N N O ie DaveBel ELECTRONIC EQUIPMENT LIMITED 7 Technical specifications Self leveling range 4 x C alkaline batteries or Ni MH Power battery pack Weight 2 5Kg 8 Maintenance e As a precision instrument it should be carefully operated and properly preserved and any violent shock or falling will possibly result in the damage of instrument e Do not attempt to disassemble the instrument and the unprofessional disassembly will result in the damage of instrument e Keep the cleanness of the laser output window and periodically remove
3. Bel b Tripod adjusting leg could keep the level position of main unit Please adjust the legs to center the bubble when use the device Especially when the laser beam flash and alarm sounds that mean the device is beyond the selfleveling range and it should adjust the legs to center the bubble Bubble should be centered c When the lock lever is in FREE position it is possible for the instrument to rotate in 360 degree on the tripodic base and it also could do the fine angle adjustment by the fine adjustment handwheel 4 4 Connect with the tripod The unit could connect with tripod directly or connect with tripod by the tripodic base Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 5 Speed setting key Y direction vertical line control modulate key X direction vertical line control key Area scan key Area shift key Area shift key Slope key Slope direction key Slope key TILT mode key Remote shield key Modulate LED X direction LED Y direction LED TILT LED Power LED 4 6 Power key Press Power key to turn on the unit After power on the power LED will light The power LED flashing means low power After power on the instrument will enter into the auto leveling status The rotating speed after leveling is about 500rpm Note In the course of auto leveling all keys are ineffective expect the
4. ccuracy Calibration According to the result of accuracy check mark a reference point O at the position that is h 2 the center of the highest and the lowest points among A B C and D lower than the highest point on the vertical line a X axis Calibration 1 Power off the instrument and make X axis in face of the wall 2 Press and keys simultaneously then release key while still pressing key until the LED flashes three times continuously then the instrument enters into the self calibration status Adjust the rotating speed for laser line clearness and visibility 3 Drop down the down calibration area cover of LS312 remote control operate the keypad in the calibration area of remote control to calibrate the instrument as follows steps Down cover 9 1 Calibration area 4 Press 772 to select X direction for sel calibration X direction LED on the keypad of the main instrument light 5 Press key to make laser line move upwards and downwards until it is coincident with the reference point O 6 Press to confirm the self calibration value Now the laser stops rotation and X axis calibration comes to an end 7 Power off the instrument b Y axis Calibration 1 Power off the instrument and make Y axis in the face of the wall 2 After enter the self calibration mode pess key to select Y direction for self calibration LED for Y direction on the
5. dust by the gentle operation of soft clean cloth or alcoholic cotton e Take the batteries out when the instrument is not in use for a long time and keep the instrument in the carrying case when it is unused e In despite of waterproof feature you d better not use the instrument in rainy days and very humid environment Mobile 022 070 6986 Email dave davebell co nz www davebell co nz
6. en the lock screw Tighten the lock screw b Take off the battery cover put 2 sets of rechargeable battery pack into the instrument as below picture shows and insert the battery plug Then Snap the battery door back and tighten the lock screw Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBell ELECTRONIC EQUIPMENT LIMITED Battery plug Rechargeable battery pack Put into the rechargeable battery packs and insert the battery plug 4 2 Charge the rechargeable battery pack Insert the special adapter to outlet jack of the instrument could start charging process If alkaline batteries are in the battery box the alkaline batteries will not be charged in this way In the course of charging the LED displays red If the LED becomes green it means the batteries have been fully charged Note Please charge the battery when the battery is empty power LED on the instrument flash means the battery is empty that could extend the battery use life 4 3 Connecting with the tripodic base a Set the lock lever to LOCK position and then it could connect the instrument with the tripodic base through the 5 8 screw thread After connection set the lock lever to FREE position then it is possible for the instrument to rotate in 360 degree on the tripodic base LOCK Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED Dave
7. ill light when press this key and then instrument can not receive the remote signal 4 14 Sleep mode The instrument will be entered into sleep mode after pressing the on off key on the remote control Now all the keys are ineffective expect the power key The instrument will be power off automatically if continuous sleep for 30 minutes 5 Self check and Calibration 5 1 Instrument Accuracy Self check Vertical line Laser line Platform a Set a platform 10m far away from a wall indoors draw a vertical line on the wall and place the instrument the platform with X axis face of the wall b Power on the instrument after auto leveling Adjust rotating speed to make the output laser line clear and visible and take the intersection point between laser line and vertical line as point A Rotate the instrument by 90 in turn and after auto leveling take the intersection points between laser line and vertical line as points B C D respectively Measure the distance h between the highest and the lowest point among D If h lt 2mm the accuracy is qualified If 2mm lt h lt 5mm the accuracy is beyond tolerance and users could calibrate the accuracy by themselves If h gt 5mm the accuracy is beyond tolerance and please contact authorized servicing centers or dealers for repairs Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED 5 2 A
8. power key press these keys without any response These keys will reactivate after auto leveling 4 7 TILT mode key a Press TILT key to enter into TILT mode and the TILT LED will light In the TILT mode if the instrument suffers from outside force and become tilted after auto leveling the TILT LED flashing the unit stops rotating the laser flashing and now the instrument will not auto level any longer b Press this key again the instrument will exit from the TILT mode and then enter into the auto leveling mode c Power on and after auto leveling the instrument will enter into tilt mode automatically after 30 sceonds 4 8 Speed setting key a In rotating mode short press this key the rotating speed can be switched between 500rpm 200rpm b Extended press this key about one second the instrument will stop rotating and the rotating laser will be off Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 9 Area Scan key a Press area scan mode key to enter into area scan mode In area scan mode press this key to switch the scan angle as follows Scan in large range scan in middle range scan in small range in just a point 0 about 60 about 30 about 5 b Press the scan range will shift clockwise press button the scan range will shift counter clockwise 4 10 Slope direction key a Press
9. slope direction key to enter into slope mode In slope mode press this key to select the slope direction X or Y direction and the relevant LED of X Y direction will be lighted b Press Oe key to adjust the slope angle Press once means fine adjustment Press continuously means quick adjustment c Press slope direction key for a long time means exiting from the slope mode d The instrument will give a sound alarm when the slope angle is beyond of auto leveling range laser line flashing and sound alarm indication meanwhile 4 11 X Y Vertical line control key Press to turn on off the vertical laser line of Y direction Press key to turn on off the vertical line of X direction X direction Y direction 4 12 Modulate key a At first the instrument is in the non modulation mode Extended press 5 LED will light and the instrument will enter into the modulation mode If the vertical line is already lighted the detector can detect the signal within the range of 40m b In the modulation mode extended press this key the LED will extinguish and the instrument will exit from the modulation mode Here the detector cannot detect any signal Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 13 Remote shield key This key is used to control the remote function it can control the instrument to receive the signal from remote LS312 or not The LED w
10. will stop rotating when be hit to ensures the instrument and ideal working accuracy e Able to make accuracy self calibration e Able to realize timed power off e Able to be operated by remote control 5 8 screw thread in the center to be connected with tripod 1 e Various accessories of elaborate design can bring usage expansion e Rainproof and dustproof 2 User Safety e Laser output sign lies near the output aperture e Do not stare into laser beam directly e Do not disassemble the instrument or attempt to perform any internal servicing Repairs and servicing could be performed only by authorized service centers instrument complies with the safety classification standards of laser radiation Mobile 022 070 6986 Email dave davebell co nz www davebell co nz M ELECTRONIC EQUIPMENT LIMITED DaveBel 3 Nomenclature 3 1 Main Body Nomenclature Laser output window Screw of battery cover Keypad Handle Charging LED Battery cove Remote receiving tube 5 8 11 screw Remote receiving tube 3 2 base Nomenclature Bubble 5 8 11 screw bolt Lock lever Fine adjustment handwheel Zero position mae 572 5 rt siede indication line support ieg 4 Operation Instruction 4 1 Battery Installation a Take off the battery cover and insert 4 C alkaline batteries as below picture shows Then Snap the battery door back and tight