1.   Tel  06221   84 42 0 info neolab de www neolab de    neoLab Berlin Tel  030   30 87 45 0 neoLab M  nchen Tel  089   35 61 88  0    Technical data     Voltage  220 230   Frequency Hz  50 60   Power  60 W   Dimensions  mm   127 x 130 x 160  Permitted ambient temp  5 40 C  Motor type  Shaded pole motor  Motor rating input  58 W   Motor rating output  10 W   Speed range  rpm   0 2500   Speed display  Scale   Orbital diameter  4 mm   Run type  continuous touch operation  Weight  3 5 kg    neoLab Migge Laborbedarf Vertriebs GmbH  Rischerstr  7 9  69123 Heidelberg    Tel  06221   84 42 0    neoLab Berlin Tel  030   30 87 45 0    info neolab de www neolab de    neoLab M  nchen Tel  089   35 61 88  0    
2. ccessories must be securely attached to the device and cannot come off by  themselves  Always disconnect the plug before fitting accessories     The instrument can only be disconnected from the main power supply by pulling out the mains plug or the  connector plug   e The voltage stated on the label must correspond to the main power supply   e The instrument may only be opened by experts   e Keep away from high magnetic held   e Observe the minimum distances between the devices  between the device and the wall and above the  assembly  min  100 mm      Proper use     The instrument is designed for mixing liquids in schools  laboratories or factories  This device is not suitable for  using in residential areas or other constraints mentioned in Chapter 1     Inspection     Unpack the equipment carefully and check for any damages which may have arisen during transport  If it  happens  please contact neolab for technical support     Trial run     Make sure the required operating voltage and power supply voltage match    Ensure the socket must be earthed reliably    Ensure the power be off   Plug in the power cable   Ensure the two direction switch must be in the middle   off state   before powering on    If these operations above are normal  the device is ready to operate  If these operations are not normal  the  device may be damaged during transportation  please contact neolab for technical support     neoLab Migge Laborbedarf Vertriebs GmbH  Rischerstr  7 9  69123 Heidelberg  T
3. el  06221   84 42 0 info neolab de www neolab de    neoLab Berlin Tel  030   30 87 45 0 neoLab M  nchen Tel  089   35 61 88  0    f  r mein Labor    neo all    Continuous Operation     Push the two direction switch leftward to ON and power LED is lit  Then the instrument begins to work   Turn the speed control knob to set the rated speed   If use the Nonstandard accessories  please ensure the speed in indicating range   Push the two direction switch rightwards gently to OFF and LED power is closed and the instrument is  turned off     Touch Operation     e Ensure the speed control knob to the lowest position  Put the instrument on a solid and safe place and  plug in the main power   e Push the two direction switch rightward to the touch mode   e Turn the speed control knob to set the rated speed   e If a test tube is pressed into mixing head vertically  the instrument will begin to work and the power LED  will be lit    e Push the two direction switch leftward gently to OFF and the instrument is turned off    Faults     e Ifa unit fault happens  please power down the instrument    If these faults are not resolved  please send the instrument back    Maintenance and Cleaning     Proper maintenance can keep instruments working in a good state and lengthen its lifetime   Be careful not spray the cleanser into the instrument when cleaning    Unplug the power line when cleaning    Only use neutral cleanse    neoLab Migge Laborbedarf Vertriebs GmbH  Rischerstr  7 9  69123 Heidelberg
4. f  r mein Labor    neo Lal    User Manual    neoLab Vortexer adjustable Speed  Item N    D 6012    Users should read this manual carefully  follow the instructions and procedures  and be aware of the  dangers while using this instrument     Safety Instructions     Warning       Read the operating instructions carefully before use the instrument  e _ Ensure that only trained staff work with the instrument    Protective ground contact     Make sure that socket must be earthed  protective ground contact  before use   When work  wear suitable protective clothing to avoid the risk from    Splashing of liquids   Mechanical vibration may lead to glass breakage   Keep medium vessels vertical as much as possible   Do not operate the instrument in explosive atmospheres with hazardous substances or under water   Put the speed control knob to the lowest position    Reduce the speed if   e The instrument is not running smoothly or moves on the stage    Beware of hazards due to     Flammable materials or media with a low boiling temperature  Overfilling of media   Unsafe container   Process pathogenic materials only in closed vessels     neoLab Migge Laborbedarf Vertriebs GmbH  Rischerstr  7 9  69123 Heidelberg  Tel  06221   84 42 0 info neolab de www neolab de    neoLab Berlin Tel  030   30 87 45 0 neoLab M  nchen Tel  089   35 61 88  0    z f  r mein Labor     neoLab    e Check the instrument and accessories before hand for damage each time you use them  Do not use  damaged components  A
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
TDA-VC 60 *72984*  モバトレ君アプリ - GMOクリック証券  Edit Hotel`s Listed Information Thi  parts catalogue news  KTI Networks SFP-GLS-W5340-A network transceiver module  ASA Electronics AOM-7694 User's Manual    Guía de Usuario  取扱説明書      Copyright © All rights reserved. 
   Failed to retrieve file