1. 331 Ushers Road P O Box 767 Clifton Park NY 12065 USA 1 518 877 5173 Fax 1 518 877 8346 mailto sales sixnetio com http www sixnetio com Micro VersaTRAK uIPm An Installation ready Interface for Real time Plant Floor Data The Micro IPm is the programmable and expandable SiteTRAK that everyone has been looking for i p Plant floor interface for Real time inventory management Remote process monitoring HVAC amp energy management Environmental monitoring Low cost OEM applications Teles os fasted seseecoesserertres el Ser di Inside this Compact RTU Industrial PowerPC true 32 bit data bus Ideal for ID tag applications Serial ports link to code readers Hoty CNA E ANE TOEG Datalogging and Timestamping Trending alarm logging amp transaction recording 16 MB of flash disk Stand Alone Control of Remote Sites 10 100 Auto detecting real time Ethernet IEC 61131 ISaGRAF and also C programming via open source Linux Up to four flexible real time serial ports Limitless Multi user Connectivity Up to 14 on board discrete amp analog I O Telephone Internet and wireless telemetry 10 100 Ethernet plus up to 4 com ports Expandable with SIXNET I O modules Embedded LINUX Open Source Software Emsa E courcacotiwate Add applications I O drivers amp much more An OEM s Dream Platform 100 VersaTRAK RTU compatible Pre certified Just add your app
2. is applied All eight discrete inputs may also be configured as sinking inputs switch closures to ground There is a selection jumper in the module s base that is easily accessed by unplugging the logic module and opening the hinged door You must also make a similar selection in the I O Tool Kit software The module performs a check to verify that the hardware and software selections match Adjustable Threshold Voltage on the Discrete Inputs All eight discrete inputs may be modified to transition at a threshold voltage lower than the factory setting This is accomplished by simply soldering an extra resistor into the base Refer to the user manual for details gt Sourcing Discrete Outputs and Watchdog Output All four discrete outputs are sourcing positive voltage outputed when ON with the standard 10 30V range The first discrete output can be configured to be a watchdog output This system performance monitor will be ON if the output circuitry CPU operation and internal communications are functioning normally High Speed and Special Counter Inputs All eight discrete inputs can be configured as counters with a flexible choice of modes These counters report their values in corresponding 16 bit analog input registers Options for fast 5 mS or slow 25 mS for contact bounce filtering response providing a maximum count rate of 100 Hz or 20 Hz counting respectively The 1 channel is a high speed counter and can count up to 10 KHz Av
3. 10 100 real time Ethernet four serial ports and flexible I O expansion connects this powerful RTU to your application z INTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNET N icro VersaTRAK yIPm Remote Terminal Unit Ethernet Internet Connectivity i Eres Ethernet eee SS ee mer a see or RS485 VeFsaT RMS Lins Hiss enn i a f a res Local I O soeecseccseaecaese Modem radio etc Plant floor diagnostics On board Operator Interfaces Ethernet I O and more SIXNET 331 Ushers Road P O Box 767 Clifton Park NY 12065 USA 1 518 877 5173 Fax 1 518 877 8346 mailto sales sixnetio com http www sixnetio com Micro IPm Performance Specs Industrial PowerPC 32 bit data bus Operating System Embedded open source LINUX Dynamic memory RAM 16 Mbytes for program execution dynamic variables dynamic file system etc Program memory Flash 16 Mbytes for Linux OS program storage and file system Retained memory RAM 512K battery backed for datalogging and retained variables Real time clock Battery backed for time stamping and other operations Local I O on board 12 or 14 see ordering info I O Expansion up to 256 RS485 or Ethernet Datalogging support Yes SIXNET Sixlog with easy to use configuration tools no programming required IEC 61131 programming Yes SIXNET ISaGRAF for ladder logic S
4. FC flow charting and more 6 languages supported High Level C programming Yes LINUX open source with FREE development tools for Windows and Linux platforms Ethernet Port 10 100BaseTx auto detecting Connection RJ45 auto mdi mdix crossover TCP IP ARP UDP ICNP DHCP Modbus TCP SIXNET and optionally PPP DNP3 and more Protocols Serial Ports Up to 115 200 baud RS485 Port A Screws 485 485 GND 2 wire half duplex RS232 Port B RJ45 TD RD CTS RTS CD DTR DSR GND RS232 Port C Screws TD RD RTS GND RS232 Port D optional Screws TD RD GND In place of the two analog inputs Protocols Master amp slave modes SIXNET amp Modbus RTU ASCII Others available as LINUX applications Environmental DIN rail or flat panel mount no accessories needed Input power 10 30 VDC Input current 100 mA 24 VDC typical Temperature 40 to 70 C 40 to 85 C storage Humidity 5 to 95 RH non condensing Flammability UL 94V 0 materials Electrical Safety UL 508 CSA C22 2 14 EN610101 IEC1010 EMI emissions FCC part 15 ICES 003 Class A EN55022 EN61326 1 EMC immunity EN61326 1 EN61000 4 2 3 4 6 Surge withstand IEEE 472 ANSI C37 90 Vibration IEC68 2 6 Hazardous locations UL 1604 CSA C22 2 213 Class 1 Div 2 Groups A B C D Cenelec EN50021 Zone 2 ATEX Marine amp Offshore Tested by DNV Det Norske Veritas to meet DNV No 2 4 Discrete Inputs Guaranteed ON voltage Maximum voltage Guaranteed OFF
5. ailable counter modes are pulse rate and run time Analog I O Features gt Self resetting Analog Input Protection Each 4 20 mA input channel has a 100 ohm high precision 0 1 percent shunt across its input to develop a 2 volt signal when a full scale 20 mA input is applied These shunts are located in the module s base giving you the advantage of maintaining a continuous circuit even if the logic module is removed from the base If excessive voltage is applied to an input a self resetting fuse will open to prevent the shunt from overheating Open Loop Detection on Analog Inputs This module can detect and report an open instrumentation loop on its analog inputs By allowing the module to report a negative value if the current falls below 4 mA low limit logic in your DCS PLC RTU or computer can signal the loss of current To enable this feature select the Go Negative Below 4 mA software setting for each channel Reading Voltage Analog Inputs For each analog input a jumper may be moved to convert the channel from 4 20 mA to 0 5 V Then voltage operation must be configured in the I O Tool Kit by selecting the appropriate range for the corresponding input hd ol I a eocee E piit Et TERTE Flexible I O Expansion aka oa N Add EtherTRAK or RemoteTRAK I O modules to either the Ethernet RTT ETE EE TEET ass ceehseeereeee eee or RS485 port on a Micro IPm for a total of up to 256 I O points O gBaabeeaeeedenes SE pranan
6. e Rees ates you to collect your emissions data into your management software requiring datalogging and alarm Pm is an OEM Solution detection at remote sites but SIXNET will gladly private label or manufacture Pm units to your exact need some Pee oes requirements The VersaTRAK IPm CPU is available to OEMs who need an more I O expansion industrially hardened platform for new product designs or to web enable existing products For more details check out http www linux4oems com SIXNET Industrial Solutions SIXNET delivers a broad line of Industrial Strength products for process control SCADA and remote site management including Industrial Phone Modems Modular Ethernet I O and RS485 I O Real time Ethernet Switches kd a nana Request Your FREE Product CD at Contact your SIXNET Applications Engineer Today http www sixnetio com For the latest information check out htto www SIXNETio com LQ Uel Z AY JOoYseIeG WdI ONIWN 331 Ushers Road P O Box 767 Clifton Park NY 12065 USA 1 518 877 5173 Fax 1 518 877 8346 mailto sales sixnetio com http www sixnetio com
7. lication Powerful Windows software tools Use this powerful industrial module as an applications ready Remote Terminal Unit RTU or as an open platform for your own gi LINUX based application Industrially rugged operation 40 to 70 C Certified to Perform E jISsoomi Class 1 Dw ll amp Marina amp European WLSos Certified Cenelac Zone 2 Offshore Community for Safety Benefits of LINUX open source software High performance without compromise a DA a Wide open for complete flexibility Advanced development tools Complete documentation Available source code 100 Internet enabled An OEMs dream platform Do anything save money Instant Products to Market All this power at your fingertips Open source reduces technical risks Insure the long life of your systems ulPm is still a user friendly VersaT RAK Supplied with powerful Windows software tools 7 If you have special needs the means to achieve your goals is in ha d LINUX is open UNIX the operating system found in the big computers UNIX has been around for 30 years and its popularity is still growing The LINUX software is invisible to the user only access it if you choose to When thousands of developers pool their resources everyone wins Five Ports Offer Limitless Connectivity INTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNETINTERNET ebeo 8 6ve a a i
8. semm E peere eee awn ee p Serr Ordering Information yrr Model Description DI DO Al RS232 RS485 Ethernet VT UIPM 431 H_ Module with wiring base 8 4 2 2 1 10100 VT UIPM 441 H_ Module with wiring base 8 4 o0 3 1 10100 SIXNET 331 Ushers Road P O Box 767 Clifton Park NY 12065 USA 1 518 877 5173 Fax 1 518 877 8346 mailto sales sixnetio com http www sixnetio com Micro IPm Applications Chemical Delivery Systems Improve the effectiveness of your Chemical Delivery Systems Control concentrations lt monitor usage create reports and reorder automatically SIXNET can provide you with lt a customized solution to meet your customer s exact demands s Tag ID Systems Micro IPm is the ideal plant floor interface for bar code and tag ID systems These programmable RTUs store database tables perform local control functions and connect to host systems Energy Management Systems Record energy usage monitor peak demand and perform load shedding functions DNP3 support records and reports time stamped events Flexible programmability easily accommodates special requirements Environmental Management The Micro IPm is a VersaTRAK IPm systems are an idyllic way to Programmable SiteTRAK effectively meet EPA and other regulations for The Micro IPm is ideal for all continuous monitoring systems while minimizing costs SIXNET makes it easy for
9. t 1424344454647 48 to 10 30 VDC ri i es _ ean sourcing or sinking DI sourcing loop or self Equivalent DO Circuit a ee DO powered Al 4 10 30 sourcing only For sinking VDC inputs connect to 10 30 VDC VT UIPM431 with 8 Di 4 DO 2 Al L RS485 amp 2 RS232 and set the Return Jumper for DC RS232 RS232 i DI m DO PotD PottC 5 OOOODODODOODOODOGDOGODOOO 1234567890WURBUH 161718 DI and DO wiring same as above AIN 100 ohms 4 20 mA or 80K ohms 0 5 V VT UIPM441 with 8 Di 4DO 1RS485 amp 3RS22 a E Micro IPm Mechanical Dimensions 0 28 _ 4 25 0 71 cm 10 80 cm N 19 20 21 22 23 24 25 er O p A 20302320 2 aa ae y 0 28 8 20 cm 2 95 pa 7490m FRONT VIEW lt rH SIDE VIEW A as oS eat ek es a ee ee es et 2 z 4567 8 3 14 7 DIN o 1 PARACE 1 1 ey _ 1 Dia 0 1 7 4 47 50022 i 1 80 Da 0 43 cm clear lt 4 75 11 35 cm 4 13 4 57 cm for 8 screw 12 07 cm I 10 48 cm a SIXNET 331 Ushers Road P O Box 767 Clifton Park NY 12065 USA 1 518 877 5173 Fax 1 518 877 8346 mailto sales sixnetio com http www sixnetio com Advanced I O Features and Capabilities Discrete I O Features 9 gt Z gt O O Discrete I O Features gt Sinking or Sourcing Discrete Inputs All eight discrete inputs can be sourcing ON when positive voltage
10. voltage Input resistance amp current Filtered ON OFF delay 25 mS 20 Hz max counting for contact bounce filtering Fast ON OFF delay 4 mS 100 Hz max counting Count rate Counter modes Poll time all channels Discrete Outputs Min amp max output load Max OFF state leakage Inrush current Typical ON characteristics Poll time all channels Analog Inputs Full scale range A D and input resolution 16 bits 0 003 2 uA current range or 0 5 mV voltage range Full scale accuracy 0 1 20 C factory calibration Span amp offset temp coeff 50 pom per degree C Inout impedance 100 Ohm current range 80 K ohm voltage Current protection 50 mS both channels configurable for longer integration times for better noise filtering Specifications are subject to change Consult factory for latest information 331 Ushers Road P O Box 767 Clifton Park NY 12065 USA 1 518 877 5173 Fax 1 518 877 8346 mailto sales sixnetio com http www sixnetio com Micro IPm Wiring Diagram l RS485 1 10 30 VDC roo Port A User Supplied RS232 Ethernet Pa E Circuits ID 4 TI Chassis RJ45 RJ45 N Yy y Port B 10 100 5 DI Return jimger 5 e Al Range Jumper Select DC for IR Select 4 20 mA i default or 0 5V 4 20 r DO Al r Port C 5 eae QOQDDDODWO To For sourcing inputs connec
Download Pdf Manuals
Related Search
Related Contents
Tecumseh AKA9457ZAADA Drawing Data radial arm maze - Med Associates Inc. S8400 OM.book - SATO - The Leader In Barcode Printing Course Outline Troubleshooting Movidrive B-low res Philips DCM105 User's Manual HBH-PV740KIT manual ENZYLIA® OPERA manual bomba condensado mini aqua Copyright © All rights reserved.