Home

User manual - ET Systems

image

Contents

1. LUE Piau Automatic Garage DoorOperator support et co Za G amp C Electronicscc TA ET Systems 15 Nelson Rd Observatory Cape Town South Africa www et co za Technical specifications may change without priornotice All goodsare subject to the standard factory waranty aslaid out on the last page of this publication Rev 2007 05 001 The following are a couple of quick reference reminders of procedures and instructions your service provider installer disc ussed with you on completion of your new garage door automation For any queries not sufficiently answered by the following please make contact with your service provider installer Failing which contact us directly for telephonic intemet support Please considerthat by automating your garage door you have created the largest moving electrical appliance in yourhome Asan appliance it needsto be respected asa danger if not used conectly Do notoperate the door without clear sight of it Ensure children and pets are kept clear of the automatic doorarea atall times Speak to your service provider about detection equipment for your type of door Check forany obstuctions before operating your door Have your service provider inspectand service your door mechanics regulary Even maintenance free doors need to be check regulary for mechanical wear How to open and close the door The two most popular waysto do this are either by remote control or by wall mount push bu
2. the beepsmean 1x beep Insufficient battery power Allow enough time to recharge If problem persists contact your service provider 2 x beeps Intenuption of household electrical supply power failure Check the plug point and distribution board 3 x rapid beeps Holiday lock out see Understanding and using holiday lock out on page 2 3 x long beeps Auto close isactive and the door is about to close Notes about the battery reserve In the case of a power failure the DC BLUE PLUS will draw all power from the batteries The available reserve is 1 2A hour at 24Vdc when fully charged The continuous draw isapproximately 29mA on standby Even though you are not running the door The unit will therefore remain powered forapproximately 12 18hrs without running the door Thereafter the doormay not run conectly The amount of times you can run the door when the power has failed willdepend on the door running load and time Please check with your installer NB Extended power failures will be detrimental to the lifespan of the batteries To prevent ireversible damage to the batteries re apply power immediately you become aware of the power interruption Or contact your electrical power supply company The battery reserve recharge time is approximately 8hrsto full charge from resumption of mains power supply This is dependent on length of standby time used Afterextended power failures minimize use of the unit forthe duration of t
3. he recharge time Allow at least 8 hours charge time after the installation of new batteries in the unit WARRANTY All goods manufactured by G amp C Electronicscc T A ETSystemscany a 12 month factory warranty from date of invoice All goodsare warranted to be free of faulty components and manufacturing defects Faulty goods will be repaired orreplaced at the sole discretion of ET Systems free of charge This warranty is subject to the goods being retumed to the premises of ET Systems The camage of goodsis forthe customers account This waranty is only valid if the comect installation and application of goods aslaid out in the applicable documentation accompanying said goods isadhered to All warranty claims must be accompanied by the original invoice All claims made by the end user must be directed to their respective service provider installer The following conditions will disqualify this product from the waranty aslaid out above These conditions are non negotiable Any single DC BLUE PLUS garage door operator used to automate more than one doorat one time Any DC BLUE PLUS garage dooroperator used outdoors including carports Any DC BLUE PLUS domestic garage door operator used in excessive traffic applications for example an apartment block parking garage Any unauthorised non manufacturer modifications to the product or components thereof
4. ld stop and wait forthe next door control tigger to reverse On closing should stop and reverse to the open position For your safety use a brick or milk crate to test this If your door initiates the obstruction sensing routine without any obvious cause try manually disengaging it from the drive system see To open and close the door manually above and then trigger your unit to run without the door If the unit completes a full open and closed cycle successfully contact your door supplier service providerto check the door If yourunit doesnot initiate the obstruction sensing routine at any point during testing contact your operator service provider installer Using the automatic close feature If you want your garage doorto close 20 seconds after opening the auto close feature must be activated Speak to your Service provider installer about this For safety reasons it is required that safety detection devices such asan infrared beam set be connected to the units control card If there is any interuption to the beam by an object in the doorarea the unit will not close If there is any interuption to the beam while the doorisclosing the door will top and retum to the open position 20 Seconds after the obstruction hasbeen cleared the door will begin closing again If auto close is selected the unit will emit three beeps before closing You can trigger the doorto close before the 20 secondstime out via the door control button What
5. lose the door 2 Pressand hold the button designated to the light control 3 When unit emits three rapid beepsasthe light flashes three times rapidly release the button 4 Any attemptsto operate the unit at this point will result in a repeat of the light and buzzer beeping and flashing The only position the doorcannot be lock in is the full open position If you want to lock the door open then stop the opening door before it reaches the full open position and follow the above procedure To deactivate holiday lock out 1 Pressand hold the button designated to the light control 2 When the unit emits three long beepsasthe light flashes three times slowly release the button 3 The operator is back to normal mode To open orclose the door manually Release the door from the operator While pulling down on the emergency release cord start moving the door with your other hand Release the cord The leverattached to the cord will spring backand you can continue moving the door manually Ifatany point the doorre engagesor postive locks repeat the first step above To re engage the door Pressthe door control button The drive will collect the door you will heara click asthe traveler sledge re engages Ifthe doordoesnot re engage by the time the motor stops running re trigger the unit and allow it to collect the door in the other direction You can also move the door gently by hand until you feel and hearit click back on to the d
6. rive system Once engaged you can continue to use the automation nomally To secure your door when the drive system is still in the open position and the power is off To lock While in manual mode asabove move the door fully closed until you feel it lock into place To un lock Triggerthe unit with the door control button t willrun and collect the door for nomal operation Ifthe powerhasnot retumed by the time you want to open the door pull the release cord and move the door Understanding the automatic obstruction sensing feature Your garage dooroperatorhasan automatic safety feature built in obstruction sensing Knowing and understanding how this feature works will help you maintain a safe and working automation system This feature monitors for any excessive physical resistance to the door while moving Most often this resistance is caused by badly maintained orun balance doors An untreated wooden door will travel differently in the rainy season asit soaksup waterand becomes heavier Extreme weather conditions can also be a cause of excessive physical resistance A fiberglass doorin a stom for instance The obstruction sensing primarily designed into your unit asa safety feature A doorclosing onto a motor vehicle also protects the unit from intemal damage Please test forthe following on a regular basis or have your service provider do the tests Your door when sensing an obstruction On opening shou
7. tton Simply pressand release the designated open close button on either the wall console or remote control If the door is Closed It will begin opening Opening It will top and wait for next triggerto close Open it will start closing Closing it will stop and re open If the holiday lock out is active unit emits three rapid beepsand courtesy light flashes three times rapidly See using holiday lock out mode How to switch the courtesy light on off The courtesy light will come on automatically when the dooris triggered to open orclose and will switch off automatically three minutes after the last operation of the door If you would like to switch the light on off without opening closing the doorsimply pressand release the button designated to the light control on either your remote or wall mount button console The light will switch off automatically after three minutes again Please note that the light control is also used for holiday lock out activation de activation See using holiday lock out mode Understanding and using holiday lock out mode The holiday lock out mode isan added feature that allows you to disallow other users from operating the door from time to time This feature is usually used where domestic workers gain access to the house via the garage Thiscan also be used if somebody is busy in the doorarea and they do not want other users to operate the door while they are there To activate holiday lock out 1 C

Download Pdf Manuals

image

Related Search

Related Contents

BB973-1 はたらく屋根エコテクノルーフ.indd  StarTech.com ESD Anti Static Wrist Strap Band with Grounding Wire  カタログ - dynabook.com  Les maladies réglementées chez les primates  Manual de usuario  BEAMPB-NR - Sunny Beam Piggy-Back  Manual de instrucciones Sistema de seguridad sin contacto CES  Manual do Utilizador do TruVision NVR 10  Technicolor - Thomson DTH109E User's Manual  